Control & navigationconsoles
2 3
Table of Contents
Navigation console Page 06
Engine control room console Page 14
Safety console Page 11
GMDSS console Page 10
Introduction Page 03
Bridge wing console Page 15
In our efficient production facility in China we produce all sorts of control & navigation consoles. Whether they’re designed by us or your engineering teams, we produce according to specified requirements.
Introduction
Design:
Solution designed according to marine or industrial standards with the top regards for safety, reliability and user-friendly operation.
Quality standards:
ISO 9001:2018 Quality Management Certification IEC 60092:2014 SER Electrical installations in Ships. IEC 60533:2015 RLV Electrical and electronic installations in ships IEC 61439:2020 RLV low-voltage switchgear and control gear assemblies SOLAS and / or IMO quality standards / rules / regulations
Classification & certification:
Marine certification according rules & regulations of:
FAT:
Factory Acceptance Test (FAT) with customer and classification society.
Packaging:
Products are packed adequately to avoid damages and losses. Wooden packaging according to UN FAO’s International Standards for Phytosanitary Measures (ISPM) No. 15, approved by International Plant Protection Convention (IPPC).
Warranty:Products in this brochure are (under normal use and service) warranted to be free of defects arising out of quality, workmanship and materials for a period of 12 months after handing over of the vessel or 18 months after date of delivery of the equipment (whichever comes first).
Maintenance & Service: Global network 24/7 service Preventive maintenance contracts
Spare parts:
Upon request we offer spare parts for all our control & navigation consoles.
4 5
6 7
Layout:1
REAR VIEW MID
Navigation console
Ergonomic design, according to available space onboard of vesselCompliant with IMO and SOLAS rules & regulationsDesigned with top quality non-reflecting aluminum top platesCustomized colour available (Standard colour RAL7035)Fully integrated and customized to meeting to client requirementsAir-cooled (forced airflow or by filters)Selection of A-brand components according the latest technologiesMaintenance access from the front and/or rear
Key features:2
Technical configuration:3
Construction
Frames are made of 2 or 3mm steel with removable panels on the front and/or at rear side and handrails are upon requests.Aluminum decoration plates for 3rd party equipment installation are optional.The displaying units are flush mounted as much as possible and located in ergonomic design, which enable easy operation and maintenance.Pneumatic front panels are optional.
IP Grade IP21Colour Standard colour RAL7035 (other colours available upon request)
Top plate Non-reflecting aluminum plates or steel plate covered with opaque Perspex.Name plates glued on the top plate
Dimensions Depends on the available space in the wheelhouse and the equipment that must be installed in the console
Picture 1: the navigation consoles for a Ropax ferry
FRONT VIEW
REAR VIEW
TOP VIEW
BOTTOM VIEW
MOUNTING PLATE
SIDE VIEW
MOUNTING PLATE
SIDE VIEW
8 9
10 11
GMDSS console Safety console
Layout:1 Layout:1
Ergonomic design, according to available space within a vesselCompliant with IMO and SOLAS rules & regulationsDesigned with top quality non-reflecting aluminum top platesCustomized colour available (Standard colour RAL7035)Fully integrated and customized to meeting to client requirementsCooling by means of forced airflowSelection of A-brand components according the latest technologiesMaintenance access from the front and/or rear
Ergonomic design, according to available space within a vesselCompliant with IMO and SOLAS rules & regulationsDesigned with top quality non-reflecting aluminum top platesCustomized colour available (Standard colour RAL7035)Fully integrated and customized to meeting to client requirementsCooling by natural ventilation or by means of forced airflowSelection of A-brand components according the latest technologiesMaintenance access from the front and/or rear
Key features:2Key features:2
Technical configuration:3Technical specifications:3
Construction
Frames are made of 2 or 3mm steel, with removable panels on the front and/or at rear side and handrails are upon requests. Aluminum decoration plates for 3rd party equipment installation are optional. The displaying units are flush mounted as much as possible and located in ergonomic design, which enable easy operation and maintenance. Pneumatic front panels are optional.
IP Grade IP21Colour Standard colour RAL7035 (other colours available upon request)Top plate Non-reflecting aluminum plates or steel plate covered with opaque Perspex
Dimensions Depends on the available space in the wheelhouse and the equipment that must be installed in the console
ConstructionFrames are made of 2 or 3mm steel, with removable panels on the front and/or at rear side and handrails are upon requests. The top cover is flat and has an inclination for displaying units which are easy to read and maintain. Pneumatic front panels are optional.
IP Grade IP21Colour Standard colour RAL7035 (other colours available upon request)
Top plate Non-reflecting aluminum plates or steel plate covered with opaque Perspex.Name plates glued on the topplate
Dimensions Depends on the available space in the wheelhouse and the equipment that must be installed in the console
FRONT VIEW
REAR VIEW
LEFT SIDE VIEW
MOUNTING PLATE SIDE
MOUNTING PLATE REARMOUNTING PLATE FRONT
MOUNTING PLATE SIDE DOOR
TOP VIEW
MOUNTING PLATE FRONT DOORREAR VIEW REAR VIEW
MOUNTING PLATEA-A
SIDE VIEW
MOUNTING PLATEB-B
BOTTOM VIEW
Picture 2: the GMDSS console for a Ropax ferryPicture 3: the safety console for a Ropax ferry
SIDE VIEW
12 13
14 15
Layout:1
Ergonomic design, according to available space within a vesselCompliant with IMO and SOLAS rules & regulationsDesigned with top quality non-reflecting aluminum top platesCustomized colour available (Standard colour RAL7035)Fully integrated and customized to meeting to client requirementsCooling by natural ventilation or forced airflowSelection of A-brand components according the latest technologiesMaintenance access from the front and/or reare access from the front and/or rear
Key features:2
Technical specifications:3
ConstructionFrames are made of 2 or 3mm steel, with removable panels on the front and/or at rear side and handrails are upon requests.The top cover is flat and has an inclination for displaying units which are easy to read and maintainPneumatic front panels are optional.
IP Grade IP21Colour Standard colour RAL7035 (other colours available upon request)
Top plate Non-reflecting aluminum plates or steel plate, or steel plate covered with opaque Perspex.Name plates glued on the top plate
Dimensions Depends on the available space in the engine control room and the equipment that must be installed in the console
Engine control room console
TOP VIEW FRONT VIEW
Layout:1
Ergonomic design, according to available space within a vesselCompliant with IMO and SOLAS rules & regulations.Designed with top quality non-reflecting aluminum top platesCustomized colour available (Standard colour RAL7035)Fully integrated and customized to meeting to client requirementsCooling by natural ventilationSelection of A-brand components according the latest technologies.Maintenance access from the front and/or rear
Key features:2
Technical specifications:3
Construction:Console located inside wheelhouse
Frames made of 2 or 3mm steel, with removable panels on the front and/or at rear side and handrails are upon requests. The top cover is flat and has an inclination.
IP Grade IP21Colour Standard colour RAL7035 (other colours available upon request)Top plate Non-reflecting aluminum plates or steel plate, or steel plate covered with opaque Perspex
Dimensions Depends on the available space in the wheelhouse and the equipment that must be installed in the console
Construction:Console located outside wheelhouse
Frames made of 2 or 3mm steel, stainless steel (AISI 304/316) 2 or 3mm, with removable panels on the front and/or at rear side and handrails are upon request.The top cover is circular arc made of stainless steel materials.
IP Grade IP56Colour Stainless steel original (other colours available upon request)Top plate The top cover is part of the console.
Dimensions Depends on the available space on bridge wing and the equipment that must be installed in the console
Bridge wing console
FRONT VIEW
Picture 5: the bridge wing console for a Ropax ferry
Picture 4: Layout of an engine control room console
Netherlands+31 (0)184 413 [email protected] 170 NL-3364DL Sliedrecht
North America+1 404 436 [email protected] Peachtee St NE Suite 1000, Atlanta Georgia
Brazil+55 47 3517 [email protected] Rua Samuel Heusi 178 Office 903 - LGN Business Center Itajai - Santa Catarina
Romania+40 (0)336 401 [email protected] Pescari 13, spatiul L.postal 800227, Galati
Middle East FZE+31 (0)184 413 [email protected] FTZ Technology ParkWH01 - Office 24 P.O. Box 55833
Singapore+65 9779 [email protected] Tuas Ave 9, 639171 Singapore
Myanmar+84 (0)225 354 [email protected] Myanmar-AMECC ShipyardBayint Naung Road Ward(4)Kamayut Township Yangon
Vietnam+84 (0)225 354 [email protected] CN 4, Nam Cau Kien IP, Thuy Nguyen Distric, Hai Phong
The Power of Reliability
China+86 (0)512 6652 [email protected] Science & Tech Park, Suzhou, Jiangsu