WirelessGateways In-Chassis
Communication Solutions for Rockwell Automation® Users
Where Automation
Connects
A S I A P A C I F I C | A F R I C A | E U R O P E | M I D D L E E A S T | L A T I N A M E R I C A | N O R T H A M E R I C A
What we can do for your facilities
Stand-Alone Gateways allow your controllers to connect to many different protocols.
Wireless Solutions optimized for AGVs, bottle filling machines, overhead conveyors, and more...
PWR
NS
ERR
MS
SER
SERIAL
ENET
Cellular GatewayICX35-HWC+
–
ANT A
ANT B
WWAN
SIM
10-30 VDC6W MAX
In-Chassis Modules allow Rockwell Automation® processors to interface easily with devices on various protocols.
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
3G/4G LTECellularGateway
IndustrialWi-Fi™
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
FL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
CompactLogix L24ERQBFC1BRUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
Secure. Remote. Access.Get to the information you need when you need it!
Cell Carrierto Internet
Firewall
Technical Support that is unparalleled in the industrial automation industry. For support and other contact information, see the back cover.
www.prosoft-technology.com2
Tutorial Videos AvailableProSoft Technology® has a number of tutorial videos available to help you get up and running on many of our products including:
• Understanding Modbus® for Rockwell Automation® Users
• Setup Tutorial for Cellular Radios
• Modbus® Setup Tutorial for ControlLogix®
• PROFIBUS DP Master Configuration Tutorial
• Setup Tutorial for 802.11 Industrial Hotspot Radios
• Setup Tutorial for Remote I/O™ to EtherNet/IP™ Migration Gateways
Visit psft.com/A8K to see our complete list of free training videos.
www.prosoft-technology.com | For a list of popular wireless solutions and part numbers, see page 12. Check for product availability in your country.
PLC
Remote Site
3G/4G CellularGateway
Control Room
EngineeringWorkstationor SCADA
Firewall
Internet
PlantNetwork
3G/4GCellular Network
PWR
NS
ERR
MS
SER
SERIAL
ENET
Cellular GatewayICX35-HWC+
–
ANT A
ANT B
WWAN
SIM
10-30 VDC6W MAX
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
Firewall
CONNECTPWR
NS
ERR
MS
SER
SERIAL
ENET
Cellular GatewayICX35-HWC+
–
ANT A
ANT B
WWAN
SIM
10-30 VDC6W MAX
10.12.1.103
192.168.0.251Remote PC Address
Cell Carrierto Internet
Drive192.168.0.050
HMI192.168.0.30
3G/4G LTECellularGateway192.168.0.250
PAC/PLC192.168.0.20
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
89
2
5
0
3
6
7
1
4
3
Industrial Cellular Gateway (M2M)Data is shared with any EtherNet/IP™-based controller, including signal strength, data usage, and more.
Features• 4G LTE with fallback to 3G; this helps ensure clear connections worldwide and longevity for your application
• Access to remote devices using secure VPN tunnels over internet connections
• Send and receive SMS texts using the EtherNet/IP object
• Supports AT&T, Verizon and many other global carriers
Secure. Remote. Access.
Features• Uses your PC’s operating-
system VPN, which minimizes the need for user-installed software
• EasyBridge™ technology enables your PC to act like it is connected directly to a switch on the remote network
• Allows software tools, such as RSWho and Studio 5000, to work without any routing
ProSoft Connect is ProSoft Technology’s secure, cloud-native platform, designed to help you gain value from the Industrial Internet of Things. ProSoft Connect allows you to monitor and troubleshoot remote automation equipment from wherever you are.
4G LTE
Check for product availability in your country. For a list of popular wireless solutions and part numbers, see page 12. | www.prosoft-technology.com
EtherNet/IP™I/O Block & Adapter
Drive
HMI
RepeaterServer
Control Room
Access Point
Repetidor Repetidor
ControlLogix®
MIMO Antenna
MIMO AntennaMIMO Antenna
89
2
5
0
3
6
7
1
4
10 2 3 4 5 6 7
ControlLogix®
VideoCamera SerialEtherNet/IP™
MIMO Antenna
Mobile Worker
Modbus® RTU(to Modbus TCP/IP Host)
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
CompactLogix™
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
4
802.11n (abgn) Fast Industrial HotspotsFeatures• Ultra-Fast access point switchover times of less than
10 ms are perfect for applications such as automated storage-retrieval systems, AGVs, and automotive skillet lines
• EtherNet/IP™ embedded object and Modbus® agent support lets users get radio diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime
• High-speed 802.11n RF data rates up to 300 Mbps (MIMO and Channel Bonding)
• WPA/WPA2-Personal (PSK, AES and/or TKIP); WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
• Quick configuration and advanced diagnostics with included IH Browser utility, embedded Web server and OPC Diagnostic Server
• Designed for extreme temperatures (-40° to +70°C), high vibration/shock and hazardous locations (UL Class 1, Div 2, ATEX Zone 2)
• Secure digital configuration storage for quick field replacement
• Hotspots can be set up as Virtual Local Area Networks (VLAN) allowing for secure network segmentation
802.11abgn Wireless Plant Architecture
2.4 GHz or 5 GHz High-Speed Wireless Network
Features• IP67 water/dust rated
• Designed for extreme temperatures (-40° to +70°C), high vibration/shock and hazardous locations (UL C1D2, ATEX Zone 2)
• Ultra-Fast Roaming with under 10 ms switchover times maintains connections for moving machines/platforms
• Power over Ethernet (PoE)
• QoS and VLAN for optimum traffic management
• WPA/WPA2-Personal (PSK, AES and/or TKIP)
• WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
802.11n (abgn) Fast Watertight Industrial Hotspots
www.prosoft-technology.com | For a list of popular wireless solutions and part numbers, see page 12. Check for product availability in your country. 5
802.11g and 802.11a High-Power Industrial Hotspots
Features• Ultra-Fast access point switchover times of less
than 10 ms are perfect for applications such as automated storage-retrieval systems and automotive skillet lines
• EtherNet/IP™ embedded object and Modbus® agent support lets users get diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime
• High RF power for longer range and coverage
• WPA/WPA2-Personal (PSK, AES and/or TKIP)
• WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
• Designed for extreme temperatures (-40° to +75°C), high vibration/shock and hazardous locations (UL C1D2, ATEX Zone 2)
• Secure digital configuration storage for quick field replacement
5 GHz2.4 GHz
Features• Special coaxial shield design uses slots to radiate
RF Signals
• Available in variable lengths, kits including all necessary accessories
• Pre-assembled cable for easy installation
• Tested for short- and medium-range distance applications (a cable up to 100 meters long connected with one radio module)
• Halogen-free low-smoke flame-retardant jacket
• Frequency Range: 2.4 GHz, 5 GHz to 6 GHz
• Operating Temperature: -40° to 85°C (-40 to 185°F)
Benefits• Wireless signal more stable in terms of response time – useful in
communicating with I/O
• Used in metallic environments, rotating/spinning machines, conveyors, AGV, warehousing, and more
Acting as a long, flexible antenna, the Radiating Cable is an alternative to traditional RF antenna systems.
Radiating Cable 2.4 and 5 GHz Band
Rotating Equipment
Control Room
EtherNet/IP™
CompactLogix™
RLX2-IHNFMaster
Radiating Cable(replaces slip-ring)
EtherNet/IP™
RLX2-IHNFRepeater
Onboard Control Panel Inside Rotating Equipment
802.11abgn Fast Industrial Hotspot
RLX2-IHNF
ANT AANT BANT C
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
FLEX I/O
10 2 3 4 5 6 7
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
PLC
FLEX I/O
Master
Repeater
Repeater
802.11abg Fast Industrial Hotspot
RLX2-IHA
ANTENNARXONLY
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
802.11abg Fast Industrial Hotspot
RLX2-IHA
ANTENNARXONLY
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
802.11abg Fast Industrial Hotspot
RLX2-IHG
ANTENNARXONLY
POWER
RF TRANSMIT
RF REC
EIVE
SERIAL
ETHERNETNET
MOD
SIGNALSTRENGTH
SCADA
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
Mobile Worker
10 2 3 4 5 6 7
Point I/O
1734-AENT
SystemPower
FieldPower
ModuleStatus
NetworkStatus
TxD
RxD
NODE:
ILX34MBS485
RS485MODBUS
ModuleStatus
NetworkStatus
TxD
RxD
NODE:
ILX34MBS232
RS232MODBUS
Check for product availability in your country. For a list of popular wireless solutions and part numbers, see page 12. | www.prosoft-technology.com
Features• Bi-directional
• 868 MHz, 900 MHz or 2.4 GHz
• Each radio can connect up to 16 I/O modules
• Available as Analog I/O 0-10 V, Analog I/O 4-20 mA & Digital/Discrete I/O
Wireless I/O What would you monitor if you didn’t have to worry about the cost of running wire? Whether you have a point-to-point application or many distributed I/O devices, our Wireless I/O solutions are a great alternative to running long wire runs. Eliminate trenching, running conduit, and the need for permits. The system can be expanded as your I/O needs grow.
Modbus
PLC Multi-PointMeter Potentiometer
SwitchSwitch
LampLamp
Point-Point
SCADA
Network-wide Access• PLC Programming• HMI Data• Diagnostics
Repeater/Remote
Remote
Master
Remote
Industrial Frequency Hopping
RLX2-IFH24E
ANTENNA
POWER
RF TRANSMIT
LINK / R
F REC
EIVE
232 /4
85
ETHERNET SIGNALSTRENGTH
DEFAULTSETTINGS
Industrial Frequency Hopping
RLX2-IFH24E
ANTENNA
POWER
RF TRANSMIT
LINK / R
F REC
EIVE
232 /4
85
ETHERNET SIGNALSTRENGTH
DEFAULTSETTINGS
902-928 MHz or 2.4 GHz
Industrial Frequency Hopping
RLX2-IFH24E
ANTENNA
POWER
RF TRANSMIT
LINK / R
F REC
EIVE
232 /4
85
ETHERNET SIGNALSTRENGTH
DEFAULTSETTINGS
Industrial Frequency Hopping
RLX2-IFH24E
ANTENNA
POWER
RF TRANSMIT
LINK / R
F REC
EIVE
232 /4
85
ETHERNET SIGNALSTRENGTH
DEFAULTSETTINGS
CompactLogix™
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
HMI
ControlLogix®
CompactLogix™
COM
M A
DAPT
ER ETHP1P2
CFGBPOK
ETH
P1App
P2App
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
Features• License-free wireless communications for Ethernet devices
• Integrated Repeater Mode to extend range and work around obstructions
• Up to 1.1 Mbps RF data rate
• Smart Switch enables automatic peer-to-peer packet routing and optimizes RF performance
• ControlScape radio management software provides configuration and online diagnostics
Ethernet Frequency Hopping RadiosAvailable in 900 Mhz or 2.4 Ghz
6
www.prosoft-technology.com | For a list of popular gateway solutions and part numbers, see page 14.
ASCII
Weigh Scale SCADA/DCSBarcodeReader
EtherNet/IP™
HMIPressure Valve
SCADA/DCSControlLogix™ L3 MicroLogix™ 1100ControlLogix™ L1
Power Monitors
Modbus® Serial Modbus® TCP/IP
PLC
Siemens® Industrial Ethernet
PLC
CompactLogix L18ERM
RUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
00:00:BC:68:0E:29
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
Ethernet and Serial Gateway Solutions
Features• Gateways with two Ethernet ports
allow you to isolate networks, passing only the data you want between devices
• EtherNet/IP gateways support multiple I/O connections for fast real-time data
• Remote configuration and diagnostics via Ethernet
• SD Card slot for disaster recovery of configuration data
• Up to four Serial ports
ProSoft Technology’s stand-alone, DIN-rail mounted industrial gateways provide a means to read or write data from devices on dissimilar protocols. All gateways come with our ProSoft Discovery Service feature. With PDS, you don’t have to change your PC to the default subnet of the module, saving you time during setup.
IEC 61850 Gateway Features• Fast, real-time data transfers with a maximum of
10,000 bytes in and 9,920 out (PLX82) or 5,000 bytes in and 4,960 out (PLX81)
• Polls up to 20 IEC 61850 server devices
• Application-specific Add-On Instructions are automatically generated
• IEC 61850 IED tags are created in your Studio 5000®/RSLogix 5000™ Project, reducing configuration time and errors
EtherNet/IP™
PLC
PROFINET®10.1.10.1 20.2.20.3
10.1.10.3
20.2.20.5
20.2.20.7
Power Relays
Drive
20.2.20.6
20.2.20.4
20.2.20.10
89
2
5
0
3
6
7
1
4
RESET
LINK/ACT
EtherNet/IP PROFINET
RESERVED
LINK
SYSSFBF
100 Mbit RX/TX
MS NS
CFG ERR
PWRFLT
PLX82-EIP-PNC
EtherNet/IP PROFINET
20.2.20.2Drive
20.2.20.3HMI
20.2.20.110.1.10.1
10.1.10.3
PROFINET I/O Devices20.2.20.4 20.2.20.5 20.2.20.6
EtherNet/IP to PROFINET GatewaysController and Device Versions
ETHERNET
RESET
ERR
FLT PWR
MS NS
CFG
LINK/ACT
100 Mbit
E1
ETHERNETLINK/ACT
100 Mbit
E2
EtherNet/IP™ IEC 61850
IEDs
10.1.10.1 20.2.20.2
20.2.20.3 20.2.20.4 20.2.20.5 20.2.20.6 20.2.20.7
10.1.10.2
7
PROFIBUS DP
& many other
protocols are
also available.
For a list of popular gateway solutions and part numbers, see page 14. | www.prosoft-technology.com
Engineering Station
EtherNet/IP™
AN-X2-AB-DHRIO
DH+
PLC-5® or SLC™
FL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
Allen Bradley®Remote I/O™
EtherNet/IP™
EtherNet/IP™I/O Block & Adapter
10 2 3 4 5 6 7
PLC-5® or SLC™
AN-X2-AB-DHRIOFL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
Allen Bradley®Remote I/O™
or DH+
EtherNet/IP™
PLC-5® or SLC™
AN-X2-AB-DHRIOFL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
PanelView™ Plus
Allen Bradley®Remote I/O™
EtherNet/IP™
PLC-5® or SLC™
AN-X2-AB-DHRIOFL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
PowerFlex®
89
2
5
0
3
6
7
1
4
8
AN-X2-AB-DHRIO Remote I/O EtherNet/IP™ Gateway Features• Replace old Remote I/O drives with new drives on EtherNet/IP™
without modifying PLC code
• Replace PanelView™ units on Remote I/O to new PanelView™ Plus 6 models on EtherNet/IP™ without modifying PLC code
• New controllers can utilize existing legacy Allen-Bradley® I/O
• Enables your Remote I/O PLC-5® or SLC™ to communicate with EtherNet/IP™ FLEX™ I/O adapters, giving you a phased migration option when your 1794-ASB spares are gone
Legacy Rockwell Remote I/O and DH+™ Modernization Solutions
Modicon® S908
Modicon® RIO Drop
TI Remote I/O
GENIUS GENIUS GENIUS
Genius® I/O Bus
Square D® I/O
Texas Instruments®RIO Rack
Genius® I/O Blocks
ControlLogix®
EtherNet/IP™
SY/MAX I/O
Legacy Competitive PLC Modernization Solutions
AN-X(2) Family of Gateways
Features• Enables Allen-Bradley® PAC via EtherNet/IP™ to
control I/O devices on legacy networks• Enables a phase-based approach for migrating
legacy control systems• Monitor mode enables testing & verification of
PAC logic before controlling I/O
EtherNet/IP™BACnet® LonWorks®
BuildingAutomation
Gateway
BuildingAutomation
Gateway
Boiler Chiller
Environmental ControlsHVAC
ControlLogix®ControlLogix®
SCADA
Building Automation Solutions
Features• Ability to interface up to 500 Building
Automation Systems' points of data
• BACnet® COV support for fast data communication while reducing traffic on the BACnet network
Improve energy efficiencies by connecting your PLC/PAC control systems to your Building Automation Systems
Building Automation
Gateways
www.prosoft-technology.com | For a list of popular in-chassis solutions and part numbers, see page 13.
Modbus®
Flow Devices Drives PowerMeasurement
ActuatedValves
Loop Controllers
Master and Slave
SCADA/DCS
Modbus®CompactLogix™ L2
Relay
CompactLogix L24ERQBFC1BRUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
COM
M A
DAPT
ER
Client and Server
AC Drive PLCPower RelayFlow Device
Modbus® TCP/IP
SCADA/DCS
SCADA/DCS
CompactLogix™ L3
Flow DevicePower Relays
PLC
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
COM
M A
DAPT
ER
Modbus® TCP/IP
SCADA/DCS
Modbus®
CompactLogix™ L1CompactLogix L18ERM
RUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
00:00:BC:68:0E:29
ModuleStatus
NetworkStatus
TxD
RxD
NODE:
ILX34MBS485
RS485MODBUS
9
Serial & Ethernet Modbus® SolutionsModbus® TCP/IP Features• Fast Multi-Server/Multi-Client
capabilities
• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance
Modbus® Serial Features• Module configuration stored within the Studio 5000®/RSLogix™
5000 project (ACD file) for simplified disaster recovery
• Add-On Profile (AOP) improves integration into Studio® 5000®/RSLogix™ 5000
• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance
Scalable Modbus® & Modbus® TCP Solutions for CompactLogix™Features• Enhanced modules allow up to 10,000 I/O words
• Lite modules allow up to 240 I/O words
• Integrated Modbus® Serial communications in 1734 Point I/O™ applications
For a list of popular in-chassis solutions and part numbers, see page 13. | www.prosoft-technology.com
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
DIAG
PROFIBUS
SYS
COM
PROFIBUS DP
DP/PA third-party coupler
PROFIBUS PA
EtherNet/IP™
CompactLogix™
Asset ManagementSoftware
DNP3 Ethernet
n
IEDs
2 31 4 5
ControlLogix®
SCADA/DCS
PROFIBUS SolutionsFeatures
• Remote configuration and diagnostics
• Solutions for PROFIBUS DP-V0 and PROFIBUS DP-V1
• Multi-Slave gateway solutions for large data transfers
• Support for PROFIBUS DP Master or PROFIBUS DP Slave connectivity
• Supports PA devices through third-party coupler
• DTM pass-through support
IEC 61850 Features • The ControlLogix® PAC is able to emulate
multiple Intelligent Electronic Devices on an IEC 61850 network
• Add-on Instruction provides logical definitions for I/O module status and control data, easing configuration and maintenance
• ProSoft Discovery Service (PDS) software initially sets the module’s IP address, so you don’t have to change your PC to the default subnet of the module
DNP3 Ethernet Module Features• Ethernet Client supports up to 40 DNP3 Ethernet
server devices such as RTUs, IEDs, and various protection relays
• Up to 20,000 points of data
• DNP3 Ethernet server allows the unit to interface to other client devices such as SCADA and DCS systems
IEC 61850 & DNP3 Solutions
Server Module
ControlLogix® CompactLogix™
Client & Server Module
IEDs/RTUs
IEC 61850
Switchgear
Transformer
ControlLogix®
SCADA/DCS
10
www.prosoft-technology.com | For a list of popular in-chassis solutions and part numbers, see page 13.
ControlLogix®
E1
E2
ERR APP OK
10/100
LINK/ACT
CONFIG
10/100
LINK/ACT
RX
TX
RX
TX
RESET
ETHERNET APPLICATION PORTS
SERIAL APPLICATION PORTS
ERR APP OK
10/100
LINK/ACT
CONFIG
10/100
LINK/ACT
RX
RX
TX
TX
RESET
ETHERNET APPLICATION PORTS
SERIAL APPLICATION PORTS
P1
P1
DCS Phased Modernization SolutionsUpgrade to Rockwell Automation’s Plant-PAx™ DCS while using existing legacy I/O.
Honeywell® IPC 620 I/O
Honeywell® IPC-620 Serial I/O Bus
Fisher PROVOX® Control I/O
PROVOX® Control Bus I/O
APACS+ I/O
ControlLogix®
ACM
OKACTIVESECURITY
ACM
OKACTIVESECURITY
SDM+
OKACTIVE
ACM
OKACTIVESECURITY
SAM
OKACTIVE
ACM
OKACTIVESECURITY
OKACTIVE
SDM+
OK
PSMMoore APACS+ I/O
11
Field I/O
Level Transmitter
PumpFlow Control
Valve
PressureTransmitter
TemperatureTransmitter
DifferentialPressure
Transmitter
To SCADA Host
C/C++ Solutions
Features• Ideal for custom algorithm applications
• Linux Virtual Machine (VM) and C/C++ development environment provided on separate DVD
• VM contains preinstalled toolchain and libraries
• VM contains the popular Eclipse IDE
• Multiple Ethernet & serial port example applications provided on VM
• Two independent Ethernet ports, and two independent serial ports (RS232/422/485)
In-Chassis Flow Computer Solutions
Features • Supports 8-16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids
• Measurement standards supported: AGA 3, 7, 8 and API 2540
• Provides Modbus® slave capability for reporting of flow measurement values to SCADA or HMI system with Modbus TCP/IP supported on MVI56E-AFC
• MVI56E-AFC provides Enron Modbus for reporting of alarm, events and archive data to third-party systems, as well as support for Flow-Cal CFX files, and transmitter calibration functions in EAFC Manager software
For Multi-Well Pad and LACT Applications
ControlLogix®CompactLogix™
Field I/O
Level Transmitter
PumpFlow Control
Valve
PressureTransmitter
TemperatureTransmitter
DifferentialPressure
Transmitter
RTU
CompactLogix L24ERQBFC1BRUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
FlowComputer
PAC
To SCADA Host
Before After
When you need another processor, but don’t want to add a PAC or PC
Mod
el
900
MHz
FH
Ethe
rnet
Rad
io 2
.4 G
Hz F
H
Ethe
rnet
Rad
io80
2.11
abgn
W
eath
erpr
oof
Indu
stria
l Hot
spot
802.
11ab
gn F
ast
Indu
stria
l Hot
spot
802.
11g
Hi
gh-P
ower
In
dust
rial H
otsp
ot
802.
11a
Hi
gh-P
ower
In
dust
rial H
otsp
ot
Indu
stria
l Cel
lula
r Ga
tew
ayPo
int-
to-P
oint
W
irele
ss I/
OM
ulti-
Poin
t W
irele
ss I/
O
RLX2
-IFH9
ERL
X2-IF
H24E
RLX2
-IHNF
-W(C
)RL
X2-IH
NFRL
X2-IH
GRL
X2-IH
AIC
X35-
HWC
BM-x
xx0-
RM1K
BM-x
xxx-
GM1K
Feat
ures
& S
peci
ficat
ions
Devi
ce C
onne
ctiv
ityEt
hern
et/S
eria
lEt
hern
et/S
eria
lEt
hern
etEt
hern
et/S
eria
lEt
hern
et/S
eria
lEt
hern
et/S
eria
lEt
hern
et/S
eria
lM
odbu
s® S
eria
l
Freq
uenc
y Ba
nd(s
)90
2-92
8 M
Hz2.
4 GH
z2.
4 &
5 GH
z2.
4 &
5 GH
z2.
4 GH
z5
GHz
Cellu
lar
Seve
ral f
requ
enci
es
avai
labl
eSe
vera
l fre
quen
cies
av
aila
ble
Regi
ons
Unlic
ense
d
Use
Allo
wed
North
Am
erica
, La
tin A
mer
ica,
Aust
ralia
, Ne
w Z
eala
nd
Glob
alGl
obal
Glob
al
North
Am
erica
, La
tin A
mer
ica,
Austr
alia,
New
Ze
aland
, Midd
le Ea
st
North
Am
erica
, La
tin A
mer
ica,
Austr
alia,
New
Ze
aland
, Midd
le Ea
st
Glob
alNo
rth
Amer
ica,
Eu
rope
, Aus
tralia
, M
iddl
e Ea
st
Nort
h Am
eric
a,
Euro
pe, A
ustra
lia,
Mid
dle
East
Wire
less
Tech
nolo
gyFr
eque
ncy
Hopp
ing
Freq
uenc
y Ho
ppin
gIE
EE 8
02.1
1abg
nIE
EE 8
02.1
1abg
nIE
EE 8
02.1
1gIE
EE 8
02.1
1a4G
LTE
Cel
lula
r HS
PAFr
eque
ncy
Hopp
ing
Freq
uenc
y Ho
ppin
g
Max
Out
door
Ran
ge
(mile
s/km
)30
mi /
48
km15
mi /
24
km5
mi /
8 km
5 m
i /8
km20
mi /
30k
m5
mi /
8 k
mUn
limite
d1-
4 m
i / 1
.6-6
.4 k
m5-
30 m
i / 8
-48
km
Fast
Roa
min
gN/
AN/
AYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Repe
ater
Mod
eYe
sYe
sYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Max
RF
Data
Rat
e1.
1 M
bps
1.1
Mbp
s30
0 M
bps
300
Mbp
s54
Mbp
s54
Mbp
sN/
AN/
AN/
A
Secu
rity/
Encr
yptio
nPr
oprie
tary
FHS
S /
128
bit A
ESPr
oprie
tary
FHS
S /
128
bit A
ES80
2.11
i / 1
28 b
it AE
S80
2.11
i / 1
28 b
it A
ES80
2.11
i / 1
28 b
it AE
S80
2.11
i / 1
28 b
it AE
S
Inte
rnal
Fire
wal
l, Pr
oSof
t Con
nect
VPN
, Op
enVP
N, IP
Sec
Prop
rieta
ry F
HSS
/12
8 bi
t AES
Prop
rieta
ry F
HSS
/ 12
8 -
to 2
56-b
it AE
S
RF B
ased
IGM
P Qu
eryi
ngN/
AN/
AYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Self-
Heal
ing
Netw
ork
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Adva
nced
Dia
gnos
tics
(sig
nal
stre
ngth
LED
s, w
eb s
erve
r, ne
twor
k m
anag
emen
t sof
twar
e,
OPC
tag
serv
er, S
NMP)
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Haza
rdou
s Lo
catio
n Ap
prov
als
Clas
s 1,
Div
2Cl
ass
1, D
iv 2
/At
ex Z
one
2Cl
ass
1, D
iv 2/
Atex
Zon
e 2
(WC)
Clas
s 1,
Div
2/ A
tex
Zone
2Cl
ass
1, D
iv 2/
Atex
Zon
e 2
Clas
s 1,
Div
2/At
ex Z
one
2Cl
ass
1, D
iv 2
Clas
s 1,
Div
2 /
Ate
x Zo
ne 2
Clas
s 1,
Div
2 /
AAt
ex Z
one
2 / C
1D2
Outd
oor/
Was
h Do
wn
Rate
d M
odel
N/A
N/A
IP67
N/A
N/A
N/A
N/A
N/A
N/A
Wire
less
App
licat
ions
Long
-Ran
ge S
CADA
Yes
Yes
N/A
N/A
Yes
Yes
Yes
N/A
N/A
Shor
t-Ra
nge
SCAD
AYe
sYe
sYe
sYe
sYe
sYe
sYe
sN/
AN/
A
Mob
ile W
orke
r (W
i-Fi)
N/A
N/A
Yes
Yes
Yes
Yes
N/A
N/A
Ethe
rNet
/IP™
Obj
ect
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Ethe
rNet
/IP™
Impl
icit
Mes
sagi
ng
(Hig
h-Sp
eed
IO)
N/A
N/A
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Seria
l DF1
, ASC
II,
Mod
bus®
, DNP
3, e
tc.
Yes
(enc
apsu
latio
n)Ye
s (e
ncap
sula
tion)
N/A
Yes
(enc
apsu
latio
n)Ye
s (e
ncap
sula
tion)
Yes
(enc
apsu
latio
n)Ye
s (e
ncap
sula
tion)
N/A
N/A
Vide
oSn
apsh
ots
Only
Snap
shot
s On
lyFa
st F
ram
e Ra
teFa
st F
ram
e Ra
teYe
sYe
sYe
sN/
AN/
A
Chec
k fo
r pro
duct
ava
ilabi
lity
in y
our c
ount
ry.
ProSoft Technology®
12 www.prosoft-technology.com
Wireless Comparison Product Selection Chart
Platform ControlLogix® CompactLogix™ or MicroLogix™ 1500 FLEX® I/O SLC™ Point I/O
Protocol/Application
AGA/API Gas & Liquid Flow Computer MVI56E-AFC MVI69-AFC MVI46-AFC
Moore APACS+ I/O CLX-APACS
ASCIIMVI56E-GSC
MVI56E-GSCXTMVI69-GSC MVI94-GSC-E MVI46-GSC
BASIC MVI56-BAS
BACnet®/IP PS56-BAS-406
BACnet® MS/TP PS56-BAS-073
‘C’ Programmable MVI56E-LDM MVI69E-LDM *
DF1MVI56-DFCM
MVI56-DFCMRMVI69-DFCM MVI94-DFCM MVI46-DFCM
DNP3 Serial MVI56-DNP MVI69-DNP MVI94-DNP MVI46-DNP
DNP3 EthernetMVI56-DNPSNET
MVI56E-DNPNETMVI69-DNPSNET MVI46-DNPSNET
EtherNet/IP™ MVI69-DFNT MVI46-DFNT
FA Control/Network MVI56E-FLN
Fisher PROVOX Control Bus I/O CLX-PVX
GE Ethernet Global Data MVI56-EGD MVI69-EGD
Generic Ethernet ASCII MVI56-GEC MVI69-GEC
HART® Multi-drop MVI56-HART MVI69-HART MVI46-HART
Honeywell® IPC-620 Serial I/O Bus CLX-422-IPC
IEC 60870-5-101 Slave MVI56-101S MVI69-101S MVI46-101S
IEC 60870-5-101 Master MVI56-101M MVI69-101M MVI46-101M
IEC 60870-5-104 Server MVI56-104S MVI69-104S MVI46-104S
IEC 61850 Server MVI56E-61850S
Johnson Controls Metasys® PS56-BAS-019
Limitorque Master MVI56-LTQ
LonWorks® PS56-LON-001
Modbus® SerialMVI56E-MCM
MVI56E-MCMRMVI56E-MCMXT
MVI69E-MBS *MVI69L-MBS *
ILX34-MBS232 *ILX34-MBS485 *
MVI94-MCM MVI46-MCMILX34-MBS232ILX34-MBS485
Modbus® Plus MVI56-MBP MVI46-MBP
Modbus® TCP/IP
MVI56E-MNETMVI56E-MNETCMVI56E-MNETR
MVI56E-MNETCRMVI56E-MNETXT
ILX56-MM
MVI69E-MBTCP *MVI69L-MBTCP *
MVI46-MNET
MVI46-MNETC
PROFIBUS DP Master MVI56-PDPMV1ILX69-PBM *
MVI69-PDPMV1PS69-DPM
MVI46-PDPMV1
PROFIBUS DP Slave MVI56-PDPS ILX69-PBS *PS69-DPS
MVI46-PDPS
Siemens® 3964R MVI56-S3964R MVI69-S3964R MVI46-S3964R
Siemens® Industrial EthernetILX56-MMMVI56E-SIE
* CompactLogix™ ONLY
ProSoft Technology®
13www.prosoft-technology.com
In-Chassis Product Selection Chart
Prot
ocol
/App
licat
ion
Appl
icat
ion
/ Pro
toco
lAl
len-
Brad
ley®
Re
mot
e I/O
™AS
CII
‘C’ P
rogr
amm
able
Se
rial
DF1
Mas
ter/
Slav
eDN
P3 S
eria
lDN
P3 E
ther
net
Ethe
rNet
/IP™
HART
® M
ulti-
drop
(4
cha
nnel
s)
Alle
n-Br
adle
y® R
emot
e I/O
™52
10-D
FNT-
RIO
ASCI
I51
02-D
FCM
-ASC
II3PL
X31-
EIP-
ASCI
IPL
X31-
EIP-
ASCI
I4
BACn
et®
/IPPS
-QS-
1010
-078
1 (2
50 P
oint
)PS
-QS-
1510
-078
1 (5
00 P
oint
)PS
-QS-
1010
-078
0 (2
50 P
oint
) PS
-QS-
1510
-078
0 (5
00 P
oint
)
BACn
et®
MS/
TPPS
-QS-
1010
-078
1 (2
50 P
oint
)PS
-QS-
1510
-078
1 (5
00 P
oint
)PS
-QS-
1010
-078
0 (2
50 P
oint
PS
-QS-
1510
-078
0 (5
00 P
oint
)
DF1
Mas
ter/
Slav
e51
02-D
FS3-
DFM
5102
-MCM
4-DF
CM4
5102
-DNP
M-D
FCM
351
02-D
NPS-
DFCM
352
01-D
FNT-
DFCM
5202
-DFN
T-DF
CM4
DNP3
Ser
ial
5102
-DNP
M-D
FCM
351
02-D
NPS-
DFCM
352
01-D
FNT-
DNPM
5201
-DFN
T-DN
PS
DNP3
Eth
erne
t52
01-D
FNT-
DNPS
NET
5207
-DFN
T-HA
RT
Ethe
rNet
/IP™
5210
-DFN
T-RI
OPL
X31-
EIP-
ASCI
IPL
X31-
EIP-
ASCI
I452
01-D
FNT-
DFCM
5202
-DFN
T-DF
CM4
5201
-DFN
T-DN
PM52
01-D
FNT-
DNPS
5201
-DFN
T-DN
PSNE
T
HART
® A
nalo
g52
08-D
FNT-
HART
(4 c
hann
els)
5228
-DFN
T-HA
RT (8
cha
nnel
s)
HART
® M
ulti-
drop
52
07-D
FNT-
HART
(4 c
hann
els)
IEC
6087
0-5-
101
Slav
e51
02-D
FCM
3-10
1S
IEC
6087
0-5-
104
Serv
er52
01-D
FNT-
104S
IEC
6185
0PL
X81-
EIP-
6185
0PL
X82-
EIP-
6185
0
LonW
orks
™PS
-QS-
1011
-078
3 (2
50 P
oint
)PS
-QS-
1511
-078
3 (5
00 P
oint
)PS
-QS-
1011
-078
3 (2
50 P
oint
)PS
-QS-
1511
-078
3 (5
00 P
oint
)51
07-M
CM-H
ART
Met
asys
® N
2PS
-QS-
1010
-078
2 (2
50 P
oint
) PS
-QS-
1510
-078
2 (5
00 P
oint
)PS
-QS-
1010
-078
2 (2
50 P
oint
) PS
-QS-
1510
-078
2 (5
00 P
oint
)
Mod
bus®
Ser
ial
5102
-MCM
-ASC
II351
02-M
CM4-
ADM
451
02-D
NPM
-MCM
351
02-D
NPS-
MCM
352
01-D
NPSN
ET-M
CM52
02-D
NPSN
ET-M
CM4
PLX3
1-EI
P-M
BSPL
X31-
EIP-
MBS
4
5207
-MNE
T-HA
RT
Mod
bus®
TCP
/IP52
10-M
NET-
RIO
5201
-MNE
T-AS
CII
5202
-MNE
T-AS
CII4
5202
-MNE
T-AD
M4
5201
-MNE
T-DF
CM52
02-M
NET-
DFCM
452
01-M
NET-
DNPM
5201
-MNE
T-DN
PS52
01-M
NET-
DNPS
NET
PLX3
1-EI
P-M
BTCP
PLX3
2-EI
P-M
BTCP
5507
-PDP
S-HA
RT
PROF
IBUS
DP
5105
-ASC
II-PD
PS51
04-D
FCM
PDP
M51
05-D
FCM
-PDP
S51
05-D
NPS-
PDPS
5205
-DNP
SNET
-PDP
S52
04-D
FNT-
PDPM
V152
05-D
FNT-
PDPS
PROF
INET
PL
X31-
EIP-
PND
PLX3
2-EI
P-PN
DPL
X82-
EIP-
PNC
Siem
ens®
Indu
stria
l Eth
erne
tPL
X31-
EIP-
SIE
PLX3
2-EI
P-SI
E
ProSoft Technology®
14 www.prosoft-technology.com
Stand-Alone Gateways Product Selection Chart
Prot
ocol
/App
licat
ion
Appl
icat
ion/
Prot
ocol
HART
®
Mul
ti-dr
op
(8 c
hann
els)
IEC
6087
0-5-
101
Slav
eIE
C 60
870-
5-10
4 Se
rver
Mod
bus®
Ser
ial
Mod
bus®
Plu
sM
odbu
s® T
CP/IP
PROF
IBUS
DP
Mas
ter
PROF
IBUS
DP
Sl
ave
PROF
INET
Alle
n-Br
adle
y® R
emot
e I/O
™52
10-M
NET-
RIO
ASCI
I51
02-M
CM-A
SCII3
5301
-MBP
-ASC
II53
02-M
BP-A
SCII4
5201
-MNE
T-AS
CII
5202
-MNE
T-AS
CII4
5105
-ASC
II-PD
PS
BACn
et®
/IPPS
-QS-
1010
-075
7 (2
50 P
oint
)PS
-QS-
1510
-075
7 (5
00 P
oint
)PS
-QS-
1010
-075
7 (2
50 P
oint
)PS
-QS-
1510
-075
7 (5
00 P
oint
)
BACn
et®
MS/
TPPS
-QS-
1010
-075
7 (2
50 P
oint
)PS
-QS-
1510
-075
7 (5
00 P
oint
)PS
-QS-
1010
-075
7 (2
50 P
oint
)PS
-QS-
1510
-075
7 (5
00 P
oint
)
DF1
Mas
ter/
Slav
e51
02-D
FCM
3-10
1S51
02-M
CM4-
DFCM
453
01-M
BP-D
FCM
5302
-MBP
-DFC
M4
5201
-MNE
T-DF
CM52
02-M
NET-
DFCM
451
04-D
FCM
-PDP
M51
05-D
FCM
-PDP
S
DNP3
Ser
ial
5102
-DNP
M-M
CM3
5102
-DNP
S-M
CM3
5301
-MBP
-DNP
S52
01-M
NET-
DNPM
5201
-MNE
T-DN
PS51
04-D
NPS-
PDPM
5105
-DNP
M-P
DPS
5105
-DNP
S-PD
PS
DNP3
Eth
erne
t52
01-D
NPSN
ET-M
CM52
01-M
NET-
DNPS
NET
5205
-DNP
SNET
-PDP
S
Ethe
rNet
/IP™
5201
-DFN
T-10
4SPL
X31-
EIP-
MBS
PLX3
1-EI
P-M
BS4
5303
-MBP
-DFN
TPL
X31-
EIP-
MBT
CPPL
X32-
EIP-
MBT
CP52
04-D
FNT-
PDPM
5205
-DFN
T-PD
PSPL
X31-
EIP-
PND
PLX3
2-EI
P-PN
DPL
X82-
EIP-
PNC
HART
® A
nalo
g52
08-M
NET-
HART
(4 c
hann
els)
5228
-MNE
T-HA
RT (8
cha
nnel
s)
HART
® M
ulti-
drop
(4
cha
nnel
s)51
07-M
CM-H
ART
5307
-MBP
-HAR
T52
07-M
NET-
HART
5507
-PDP
S-HA
RT
IEC
6087
0-5-
101
Slav
e51
02-M
CM3-
101S
5201
-MNE
T-10
1S51
05-1
01S-
PDPS
IEC
6087
0-5-
104
Serv
er52
01-1
04S-
MCM
52
02-1
04S-
MCM
453
03-M
BP-1
04S
5201
-MNE
T-10
4S
IEC
6185
0PL
X81-
MNE
T-61
850
PLX8
2-M
NET-
6185
0
LonW
orks
™PS
-QS-
1011
-015
4 (2
50 P
oint
)PS
-QS-
1511
-015
4 (5
00 P
oint
)PS
-QS-
1011
-015
4 (2
50 P
oint
)PS
-QS-
1511
-015
4 (5
00 P
oint
)
Met
asys
® N
2PS
-QS-
1010
-011
7 (2
50 P
oint
)PS
-QS-
1510
-011
7 (5
00 P
oint
)PS
-QS-
1010
-011
7 (2
50 P
oint
)PS
-QS-
1510
-011
7 (5
00 P
oint
)
Mod
bus®
Ser
ial
5127
-MCM
-HAR
T51
02-M
CM3-
101S
5201
-104
S-M
CM52
02-1
04S-
MCM
451
02-M
BS3-
MBM
5102
-MCM
4-DF
CM4
5301
-MBP
-MCM
5302
-MBP
-MCM
452
01-M
NET-
MCM
5202
-MNE
T-M
CM4
5104
-MCM
-PDP
MV1
5105
-MCM
-PDP
SPL
X31-
PND-
MBS
PLX3
1-PN
D-M
BS4
Mod
bus®
Plu
s53
03-M
BP-M
NET
5304
-MBP
-PDP
M53
05-M
BP-P
DPS
Mod
bus®
TCP
/IP52
01-M
NET-
101S
5201
-MNE
T-10
4S52
01-M
NET-
MCM
52
02-M
NET-
MCM
453
03-M
BP-M
NET
5204
-MNE
T-PD
PM52
05-M
NET-
PDPS
PLX3
1-M
BTCP
-PND
PLX3
2-M
BTCP
-PND
PLX8
2-M
BTCP
-PNC
PROF
IBUS
DP
5105
-101
S-PD
PS52
05-1
04S-
PDPS
5105
-MCM
-PDP
S53
04-M
BP-P
DPM
V153
05-M
BP-P
DPS
5204
-MNE
T-PD
PMV1
52
05-M
NET-
PDPS
PROF
INET
PL
X31-
PND-
MBS
PLX3
1-PN
D-M
BS4
PLX3
1-M
BTCP
-PND
PLX3
2-M
BTCP
-PND
PLX8
2-M
BTCP
-PNC
Siem
ens®
Indu
stria
l Eth
erne
tPL
X31-
MBT
CP-S
IEPL
X32-
MBT
CP-S
IE
ProSoft Technology®
15www.prosoft-technology.com
Stand-Alone Gateways Product Selection Chart
Worldwide Offices
CATALOG_RA_2017_EN
Asia PacificRegional OfficePhone: [email protected] spoken: Bahasa, Chinese, English, Japanese, Korean
REGIONAL TECH SUPPORT [email protected]
North Asia (China, Hong Kong)Phone: [email protected] spoken: Chinese, English
REGIONAL TECH SUPPORT [email protected]
Southwest Asia (India, Pakistan)Phone: [email protected] spoken: English, Hindi, Urdu
Australasia (Australia, New Zealand)Phone: [email protected] spoken: English
Southeast Asia (Singapore, Indonesia, Philippines)Phone: [email protected] spoken: English, Bahasa, Tamil
Northeast & Southeast Asia (Japan, Taiwan, Thailand, Vietnam, Malaysia)Phone: [email protected] spoken: English, Chinese, Japanese
Korea Phone: [email protected] spoken: English, Korean
Europe / Middle East / AfricaRegional OfficePhone: +33.(0)[email protected] spoken: French, English
REGIONAL TECH SUPPORT [email protected]
Middle East & AfricaPhone: [email protected] spoken: Hindi, English
REGIONAL TECH SUPPORT [email protected]
North Western Europe (UK, IE, IS, DK, NO, SE)Phone: +44.(0)[email protected] spoken: English
Central & Eastern Europe, FinlandPhone: [email protected] spoken: Polish, English
Russia & CISPhone: [email protected] spoken: Russian, English
Austria, Germany, SwitzerlandPhone: +33.(0)[email protected] spoken: English
BeNeLux, France, North AfricaPhone: +33(0)[email protected] spoken: French, English
Mediterranean CountriesPhone: [email protected] spoken: Italian, English, Spanish
Latin AmericaRegional OfficePhone: [email protected] spoken: Spanish, English
REGIONAL TECH SUPPORT [email protected]
BrazilPhone: [email protected] spoken: Portuguese, English
REGIONAL TECH SUPPORT [email protected] MexicoPhone : [email protected] spoken: Spanish, English
REGIONAL TECH SUPPORT [email protected]
Andean Countries, Central America & Caribbean Phone: +507.6427.48.38 [email protected] spoken: Spanish, English
Southern Cone (Argentina, Bolivia , Chile, Paraguay & Uruguay)Phone: [email protected] spoken: Spanish, English
North AmericaRegional OfficePhone : [email protected] spoken: English, Spanish
REGIONAL TECH SUPPORT [email protected]
© 2001–2017by ProSoft Technology, Inc.All rights reserved.
www.prosoft-technology.com
Tech SupportProSoft Technology's technical support is unparalleled in the industrial automation industry. To continue our world-class technical support, we have opened offices in most time zones in an effort to support our customers at a local level. See Regional Tech Support contact information above.