CombiTac program
Simultaneous energy connection
Applications
Compressed air
Industrial vacuum
Cooling fluids
Electricity
CombiTacprogram
2 3
A centralized connection for increased productivity and optimal safety
• A single move to connect the energy circuits of your process equipments and on-site maintenance (cycles of connection from 1 to 5 a day)
• A single coupling position to eliminate any risk of circuit inversions
• High performing guiding and locking systems, for safe connections.
Modules equipped for pneumatic circuits and industrial vacuum
Modules equipped for cooling circuits Modules equipped for electrical circuits
• 2 nominal bores: 03 - 06 mm
• RCT 03: full flow or single shutoff socket
• RCT06: single shutoff.
• 1 nominal bores: 03 mm
• non-spill design
• double shutoff.
• 5 nominal pin diameters: 1 - 1.5 - 3 - 6 - 8 mm
• gold or silver plated contacts.
• upon request, electrical contacts for coaxial cables, optical fibres, thermocouples.
• 3 nominal bores: 04 - 06 - 08 mm
• full flow.
RCT
SCT MultilamsTM, MC® technology
UCT
2 3
Because every application deserves an adapted answer, you compose your own CombiTac solution from a complete range of already equipped modules, according to your needs.
Designed to be integrated• in a mobile housing and its base for manual
connections,
• in a rackable solution for automatic connections, our programs fit in every configuration.
A solution of your choice for targeted performances
CombiTac program: the winning combination
A wide choice of equipped modules and 2 assembly configurations
MOBILE
HOUSING
RACKABLE
Compressed air - Industrial vacuum
Part numbers modules fitted with UCT
full flow
UCT 04
18
2
217 6socket UCT 104 02 1904
plug UCT 104 02 6904
217 1/4socket UCT 104 02 1933
plug UCT 104 02 6933
30
4
217 6socket UCT 104 04 1904
plug UCT 104 04 6904
217 1/4socket UCT 104 04 1933
plug UCT 104 04 6933
Compressed air
Number of UCT
per module
Description UCT 04 Part numbersmodules fittedwith UCT 04
Working pressure
Psi
Tube outside øUCT Type
mm ”
UCT 06
18
1 217 8 (5/16”)
socket UCT 106 01 1906
plug UCT 106 01 6906
28
2 217 8 (5/16”)
socket UCT 106 02 1906
plug UCT 106 02 6906
42
4 217 8 (5/16”)
socket UCT 106 04 1906
plug UCT 106 04 6906
Compressed air
Number of UCT
per module
Description UCT 06 Part numbersmodules fittedwith UCT 06
Working pressure
Psi
Tube outside øUCT Type
mm ”
4 5
UCT 08
22
1
217 10socket UCT 108 01 1908
plug UCT 108 01 6908
217 3/8socket UCT 108 01 1935
plug UCT 108 01 6935
42
2
217 10socket UCT 108 02 1908
plug UCT 108 02 6908
217 3/8socket UCT 108 02 1935
plug UCT 108 02 6935
Compressed air
Number of UCT
per module
Description UCT 08 Part numbers modules fitted with UCT 08
Working pressure
Psi
Tube outside øUCT Type
mm ”
Test conditions:• direction of flow: socket plug• supply pressure: 87 psi
Pneumatic flow rate / pressure drop
Technical characteristics
Nominal bore (mm) 04 - 06 - 08 (5"/32 - 1"/4 - 3"/8)
Max. working pressure (psi) 217Mini working pressure (torr) 10Working temperatures (°F) +5 to +194Shutoff full-flowSeals NBR
Connection onto calibrated polyamide or polyurethane tubing by instant fitting.
4 5
Compressed air - Industrial vacuum
Modules fitted with RCT sockets and plugs
full flow single shutoff
RCT 03 Full flow or single shutoff
18
2
217 4 (5/32”)socket RCT 103 02 1902/OS RCT 103 02 1902
plug RCT 103 02 6902
217 6socket RCT 103 02 1904/OS RCT 103 02 1904
plug RCT 103 02 6904
217 1/4socket RCT 103 02 1933/OS RCT 103 02 1933
plug RCT 103 02 6933
30
4
217 4 (5/32”)socket RCT 103 04 1902/OS RCT 103 04 1902
plug RCT 103 04 6902
217 6socket RCT 103 04 1904/OS RCT 103 04 1904
plug RCT 103 04 6904
217 1/4socket RCT 103 04 1933/OS RCT 103 04 1933
plug RCT 103 04 6933
Compressed air
Number of RCT
per module
Description RCT 03 Part numbers modules fitted with
Working pressure
Psi
Tube outside øRCT Type RCT 03 RCT 03
mm ”
RCT 06 Single shutoff
22
1 217 8 (5/16”)
socket RCT 106 01 1906
plug RCT 106 01 6906
42
2 217 8 (5/16”)
socket RCT 106 02 1906
plug RCT 106 02 6906
Compressed air
Number of RCT
per module
Description RCT 06 Part numbers modules fitted with
Working pressure
Psi
Tube outside øRCT Type RCT 06 RCT 06
mm ”
Test conditions:• direction of flow:
socket plug• supply pressure: 87 psi
Pneumatic flow rate / pressure dropTechnical characteristics
Nominal bore (mm) 03 - 06(1"/8 - 1"/4)
Max. working pressure (psi) 217Mini. working pressure (torr) 10Working temperature (°F) +5 to +194Shutoff full flow or single shutoffSeals NBR
Connection onto calibrated polyamide or polyurethane tubing by instant fitting.
RCT
03
RCT
03
RCT
06
6 7
Cooling fluids
Part numbers modules fitted with SCT
non-spill design – double shutoff
SCT 03 for G 1/8 female connection
SCT 05 Also available for the rackable versions: to consult us.
18
2 217 G 1/8 female
socket SCT 103 02 1100
plug SCT 103 02 7100
30
4 217 G 1/8 female
socket SCT 103 04 1100
plug SCT 103 04 7100
Cooling
Number of SCT
per module
Description SCT 03 Part numbers modules fitted
with SCT 03Working pressure
PsiConnection
SCT Type
Test condition• direction of flow: plug socket• hydraulic oil INVAROL FJ13 (H515 at 104°F)• density: 833 kg/m3
• viscosity: 13.4 cSt
Test conditions:• direction of flow: plug socket• supply pressure: 87 psi
Hydraulic flow rate / pressure drop
Pneumatic flow rate / pressure drop
Technical characteristicsNominal bore (mm) 0.3
(1"/8)Max. working pressure (psi) 217Mini. working pressure (torr) 10Working temperature (°F) +5 to +194Shutoff doubleSeals NBR
Connection onto calibrated polyamide or polyurethane tubing by instant fitting.
6 7
Electricity
Part numbers modules fitted with electrical contacts
Ø 3 mm
10
325-
352.5 - 4 600
socket ECT 130 03 1004/D
pin ECT 130 03 6004/D
10
2 active
contacts 25-
352.5 - 4 600
socket ECT 130 03 1004/GND/D
1ground pin ECT 130 03 6004/GND/D
ElectricityNumber
ofcontacts
Ratedcurrent
A
Cable cross section
mm2
Ratedvoltage
V
Type of contact
Part numbers modules fitted with
gold plated n
Ø 1 mm
4
62- 5
0.25 -
0.75300
socket ECT 110 06 1001/D
pin ECT 110 06 6001/D
20
152- 5
0.25 -
0.75300
socket ECT 110 15 1001/D
pin ECT 110 15 6001/D
18
262- 5
0.25 -
0.75300
socket ECT 110 26 1001/D
pin ECT 110 26 6001/D
ElectricityNumber
ofcontacts
Ratedcurrent
A
Cable cross section
mm2
Ratedvoltage
V
Type of contact
Part numbers modules fitted with
gold plated n
Ø 1,5 mm
6
55-
10
0.5 -
1.5600
socket ECT 115 05 1002/D
pin ECT 115 05 6002/D
ElectricityNumber
ofcontacts
Ratedcurrent
A
Cable cross section
mm2
Ratedvoltage
V
Type of contact
Part numbers modules fitted with
gold plated n
8 9
Ø 6 mm
16
2
40 6 600socket ECT 160 02 1006
pin ECT 160 02 6006
80 10 600socket ECT 160 02 1010
pin ECT 160 02 6010
16
1 16 -
socket ECT 160 01 1016/GND
pin ECT 160 01 6016/GND
ElectricityNumber
ofcontacts
Ratedcurrent
A
Cable cross section
mm2
Ratedvoltage
V
Type of contact
Part numbers modules fitted with
silver plated n
Ø 8 mm
18
2
80 10 600socket ECT 180 02 1010 ECT 180 02 1010/D
pin ECT 180 02 6010 ECT 180 02 6010/D
100 16 600socket ECT 180 02 1016 ECT 180 02 1016/D
pin ECT 180 02 6016 ECT 180 02 6016/D
125 25 600socket ECT 180 02 1025 ECT 180 02 6025/D
pin ECT 180 02 6025 ECT 180 02 6025/D
16
1 25 -
socket ECT 180 01 1025/GND
pin ECT 180 01 6025/GND
ElectricityNumber
ofcontacts
Ratedcurrent
A
Cable cross section
mm2
Ratedvoltage
V
Type of contact
Part numbers modules fitted with
silver plated n
Part numbers modules fitted with
gold plated n
The values given correspond with the operating conditions below: • rated voltage: phase / earth AC DC,
pollution level 2 and overvoltage category II, conformity with IEC 60664-1 (additional data on page 19)
• Rated current maximum cable cross section and 68°F working temperature (for other temperatures and cable cross sections, refer to the derating diagrams on page 10)
Recommendations:
• connection and disconnection off-load.
• in accordance with the IEC/TR 61201 standard, the extra low voltages are 33 Vac and 70 Vdc. For any application with higher voltages, extra protection measures must be taken (protective shields, circuit breakers, etc).
For all other operating conditions, contact your Stäubli specialist.
8 9
For solutions with modules fitted with electrical contacts next
to modules fitted with cooling couplings, it is imperative
to regularly check the good state and functionality of products
and to replace them if necessary.
All electrical contacts on the Combitac modules have to be crimped.
Electrical data
Derating diagrams
Determination of the rated current according to temperature.The derating diagram shows the continuous current (not intermittent) that
flows through all the contact elements of a connector at one time, whereby the max. temperature limit is not exceeded. Calibration and test method according to IEC 60512-5-2).
The derating diagram values are valid for the connection (see standard EN 60204). The permissible current load of the cables can be seen in DIN VDE 0298-4 and DIN EN 60204-1, IEC 60204-1.
Electrical contacts with cable cross sections of 0.25 to 1.5 mm2
Electrical contacts with cable cross sections of 2.5 to 25 mm2
Cables with 5, 6, 15 and 26 strand conductors, according to DIN VDE 0298-4 with Cu conductors with cross sections of 0.25, 0.5, 0.75 and 1.5 mm2
with PVC insulation (with high temperature resistance 194° F).
Cables with 2 and 3 strand conductors, according to DIN VDE 0298-4 with Cu conductors with cross sections of 2.5, 4, 6, 10, 16 and 25 mm2
with PVC insulation (with high temperature resistance 194° F).
10 11
Rated current:
the continuous current which can flow through every contact simultaneously without the temperature exceeding the allowed upper limit. The quoted current values were determined in a 4 hour temperature test according to UL 1977 with all contacts in series.
Rated voltage:
this is derived from the ac or dc line-to-earth (ground) voltage according to ICE 60664-1. In service, the rated voltage is dependent on whether the supply is: • 3 phase, 4 wire, with earthed
(grounded) neutralor• 3 phase, 3 wire, unearthed
(not grounded)or• 1 phase, 2 wire, AC or DC.
Overvoltage categories CAT II:
(ICE 60664-1). Equipment of Overvoltage Category II is energy-consuming equipment to be supplied from the fixed installation. Examples of such equipment are house-hold appliances and portable tools.
Pollution degree 2:
Normally only non-conductive pollution accurs. Occasionally, however, a temporary conductivity caused by condensation is to be expected.
Tools
• Delivered with assembly instruction sheet.• All electrical contacts on the CombiTac modules have to be crimped.
Part numbers Conductor cross section (mm2) Name
a 18.3800 crimping pliers
b 18.3801 0.14 - 4 crimping die adjustable
c 18.3804 0.25 - 0.75 crimping die
d 18.3805 0.5 - 1.5 crimping die
e 18.3806 2.5 - 4 crimping die
f 18.3700 crimping pliers
g 18.3701 6 crimping die
h 18.3702 10 crimping die
j 18.3703 16 crimping die
k 18.3704 25 crimping die
a
b
c d e
f
g h j k
Pin and socket assembly and disassembly tools
Part numbers nominal pin/socket ø (mm)
33.3001 1
38.3003 1.5
18.3010 3
18.3013 6
18.3016 8
18.3002 1
18.3005 1.5
18.3012 3
18.3018 6
18.3722 8
18.3001 1
18.3004 1.5
18.3011 3
18.3017 6/8
0.37
10 11
assembly tool
pin disassembly tool
socket disassembly tool
A solution for every configuration:- 6 housing and base sizes- straight or side outlet
- bases in raised version, outlet 90° - mobile base for extension: housing
equipped with locking system
Housings
Options :
• according to your configuration, the base can be fitted with protective covers against shocks and external pollution.
• a protective shield against electric shocks can be added to the mobile housing (sizes 2 to 6) or to the fixed bases (sizes 2 to 5). Depending on the operating conditions and above certain voltages, it may be mandatory (refer to ICE/TR 61201) standard.
Construction :
• aluminium alloy• base fitted with flat seal for proper
sealing onto panel.
The CombiTac range is certified IP 65
(refer to IEC 60529) in connected position and with the use of an adequate cable box (not supplied): protection against dust and water jets (from a hose).
Straight outlet mobile housing Side outlet mobile housing
C
B
A
F
F
A C
B
A1
F
B
CD
Dimensions of fixed bases (not equipped)
Sizes A B C A1 D 1 outlet F
1 2.36 2.76 1.69 2.87 0.98 M 32x1,5
2 2.87 2.76 1.69 3.50 1.34 M 32x1,5
3 3.68 2.99 1.69 4.31 1.38 M 32x1,5
4 4.72 3.07 1.69 5.35 1.38 M 32x1,5
5 3.74 3.11 3.25 4.37 1.30 M 40x1,5
6 5.16 4.13 3.50 - - M 50x1,5
Mobile housing with locking system
12 13
Dimensions of fixed bases
Dimensions of fixed bases* in raised version, outlet 90°
Sizes A B C D E (with cover)
1 3.15 1.12 1.71 0.98 0.98
2 3.66 1.12 1.71 1.34 1.02
3 4.45 1.12 1.71 1.38 1.02
4 5.51 1.12 1.71 1.38 1.02
5 4.88 1.42 3.31 1.30 0.98
6 6.50 1.52 3.54 1.97 0.98
Sizes A B C D E (with cover)
2 outlets F
1 3.23 2.89 2.24 0.87 0.79 M 32x1,5
2 3.70 2.91 2.24 1.18 0.79 M 32x1,5
3 4.61 3.01 2.24 1.18 0.79 M 32x1,5
4 5.67 3.09 2.24 1.18 0.79 M 32x1,5
5 4.96 3.09 3.25 1.30 0.87 M 32x1,5
6 5.51 3.88 4.72 1.46 0.41 M 40x1,5
Base with cover
Base with cover
A D C E
B
A D C
B
A D C E
BF F
A D C
BF F
Base without cover
Base without cover
* Base supplied with 1 cap.
12 13
• Standard configuration • other possible encoding for asymetric configuration
fixed base
high screw heads low screw heads
mobile housing
fixed base
mobile housing
fixed base
mobile housing
fixed base
mobile housing
Encoding solutions
• there are additional encoding solutions for size 5 and 6 housings.
14 15
Parking bases
Base for coupling to a mobile housing fitted with:Part numbers Parking bases
size 1 size 2 size 3 size 4 size 5 size 6
sockets 34.0340 34.0342 34.0344 34.0346 34.0348 34.0350
plugs and/or pins 34.0341 34.0343 34.0345 34.0347 34.0349 34.0351
Panel cutting of fixed bases
Sizes A B C D E
1 2.05 1.42 2.76 1.26 M4
2 2.56 1.42 3.27 1.26 M4
3 3.39 1.42 4.06 1.26 M4
4 4.33 1.42 5.12 1.26 M4
5 3.23 2.80 4.33 2.56 M5
6 4.61 3.19 5.83 2.76 M6
A
C
C
B
DD
Panel cutting of raised fixed bases
Sizes C D E
1 2.76 1.77 M5
2 3.23 1.77 M5
3 4.13 1.77 M5
4 5.20 1.77 M5
5 4.41 2.64 M5
6 4.37 4.17 M6
A
C
C
B
DD
Sizes and useful lenghts
Sizes Useful length L (inches)
1 1.45
2 2
3 2.8
4 3.82
5 2.8
6 3.82
L
L
Sizes 1, 2, 3 and 4
Sizes 5 and 6
Installation
Maximum allowable misalignment while connecting
Maximal distance in a connected state
Rackable solutions
1.38
0.75
2 x Ø 0.17
0.83
0.49
1.40
L+1.
73
L+1.
30
L
Y = 0.04 X = 0.04
L = Sum of modules widths.Minimal length = 0.71 inch if necessary, possibility of completing with spacers.
Recommendation:
The rackable installation guiding columns are only intended to guide the CombiTac. They are in no way meant to be used to guide the complete rack assembly. In that case it is necessary to ensure a preguiding of your installation.
0.98
+0.
079
0
screws not supplied
14 15
H 1
50.0
1 us
B
www.staubli.com
Stäubli units Connectors distributors
International sales coordinationStäubli Faverges - BP 70 - F - 74210 FavergesTel.: +33 (0) 4 50 65 67 97 - Fax: +33 (0) 4 50 65 60 69e mail: [email protected] is a trademark of Stäubli International AG, registered in Switzerland and other countries.© Stäubli, 21/06/2011
Belgium Tel.: +32 (0) 56 36 40 03 [email protected]
Czech Republic, Slovakia, Hungary, Romania Tel.: +420 466 616 125 [email protected]
France Tel.: +33 (0)1 69 93 25 00 [email protected]
Germany, Austria Tel.: +49 (0) 921/883-80 [email protected]
Italy Tel.: +39 (0) 362/944.1 [email protected]
Poland Tel.: +48 42 636 85 04 [email protected]
Portugal Tel.: +351 22 978 39 56/50 [email protected]
Russia Tel.: + 7 812 3344630 [email protected]
Spain Tel.: +34 937 205 405 [email protected]
Switzerland Tel.: +41 (0) 43/244 22 33 [email protected]
United Kingdom Tel.: +44 (0) 1952 671 918 [email protected]
Brazil Tel.: +55 (0) 11 5182 7600 [email protected]
North America (USA, Canada, Mexico) Tel.: +1 864/433-1980 [email protected]
China Tel.: +86 571 86912161 [email protected]
Hong Kong Tel.: +852-2366 0660 [email protected]
Japan Tel.: +81 6 6889 3308 [email protected]
Singapore Tel.: +65 / 6266 0900 [email protected]
South Korea Tel.: +82 53 753 0044 [email protected]
Taiwan Tel.: +886-2-2568 2744 [email protected]
Turkey Tel.: +90 212/472 13 00 [email protected]