Page 1 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Catalog 2016 PIRO Pipetting Robot equipment/spare parts
Page 2 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Content:
PIRO Robot page 3
PIRO Additions page 4
PIRO Tips page 5
PIRO Tip Rack / Plate Racks page 6 – 10
PIRO Adapters page 11 – 12
PIRO Tube Racks page 13 – 15
PIRO Waste Solutions page 16
PIRO Additional Equipment page 17
Transport Package page 18
Service of the PIRO® Pipetting Head page 18
Information page 19
Page 3 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Part Number/Name Additional Description
Robot
P600081 PIRO Pipetting Robot
Pipetting Robot, including Pipetting Head 200 (P100314) and 12 Racks as a basic equipment: 1x Waste Channel (P100322), 1x Waste Rack (P100321), 3x Tips Racks (P100317), 2x 96-Well Plate Racks (P100318), 2x Plate Rack-1 (P100319), 1x Plate Rack-2 (P100417) 1x Tube Rack (P100323) 1x Tube Rack (P100487). Starter kit components: 4x 96 tips 50 µl + 4x 96 tips 200 µl, Power Cable + USB Cable + PIRO software on CD + Manual (printed version) For additional equipment, please contact [email protected] or send request for an offer. Computer Requirements: Minimum specifications to run the PIRO software: Windows 7; Intel Core i3 2100, 2x 3.10 GHz or similar or more, 4 GB RAM, 250 GB Hard disc, USB-drive, Graphic card: 1 GB memory, 1366 x 768 Pixel (widescreen), Monitor: Widescreen.
Page 4 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Part Number/Name Additional Description
PIRO Additions
P100314 Pipetting Head 200
Single Channel Pipetting Head with level sensing Volume Range 1 µl - 200 µl (for tip sizes: 50µl, 200µl, 1000µl)
P100315 Pipetting Head 1000
Single Channel Pipetting Head with level sensing Volume Range 5 µl - 1000 µl (for tip sizes: 50µl, 200µl, 1000µl)
P100332 UV unit complete
Including UV unit and UV-lamp (original part for retrofitting of all PIRO instruments)
P100334 HEPA Filter unit complete
Including hardware unit , connecting cables and filters (original part for retrofitting of all PIRO instruments)
Page 5 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Tips
P100328 Tip 50 µl sterile
One box of 5 x 960 filtered tips, sterile Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P100329 Tip 200 µl sterile
One box of 5 x 960 filtered tips, sterile Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P600067 Tip 1000 µl sterile
One box of 5 x 960 filtered tips, sterile Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P600091 Tip 50 µl PCR-clean
One box of 5 x 960 filtered tips, PCR-clean Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P600092 Tip 200 µl PCR-clean
One box of 5 x 960 filtered tips, PCR-clean Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P600093 Tip 1000 µl PCR-clean
One box of 5 x 960 filtered tips, PCR-clean Certified free of: RNase, DNase, Pyrogen, DNA/RNA
P600094 Mastermix Tubes 25 x 5 ml
One bag of 25 tubes 5 ml tube with screw cap Certified free of: RNase, DNase, Pyrogen, DNA/RNA
Page 6 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Tip Rack / Plate Racks
P100317 Tip-Rack SBS Standard
For standard tip frames (P100328- 50 µl, P100329 - 200 µl, P600067 - 1000 µl)
P100318 Plate Rack-1 SBS 96 Wells
With 96-well grid For semi-skirted PCR plates and non-skirted PCR plates. Examples see below: (Note: Please check for availability of calibrated Rack/Tube combinations in PIRO software plates database) (Note: Please check for accurate tube z-value setting and correct if necessary in PIRO software)
96-well half-skirted low profile 96-well half-skirted
96-well unskirted 0.2 ml single tubes
0.2 ml 8-strip tubes 0.2 ml 12-strip tubes
Page 7 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P100319 Plate Rack-1, SBS Standard
Plate Rack for all kind of full-skirted plates. Examples see below: (Note: Please check for availability of calibrated Rack/Tube combinations in PIRO software plates database) (Note: As plastic consumables may vary in dimensions slightly, please check accurate tube z-value setting and correct if necessary in PIRO software)
384-well plate micro titer plates, Micro titer plates, PCR plates For semi-skirted PCR plates and non-skirted PCR plates: Please use in combination with cooling adapters:
P100516 P600063 P600004 Cooling adapter Cooling adapter Cooling adapter 96 well low 96 well universal 384 well
P100319 also fits for RotorGene Q and Corbett Rotor-Gene
Third Party Adapter Qiagen (RotorGeneQ) (4-tubes Strip tube) RotorGeneQ 72-well Strip tube adapter
Page 8 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P100417 Plate Rack-2, SBS Standard
Flat top Rack for deep well plates and cooling adapters high
For all kind of deep well plates and troughs.
Examples see below:
Also for use with P100515
96-well cooling adapter high
96-well half-skirted low profile, 96-well non-skirted, 96-well half-skirted
0.2 ml 8-strip tubes, 0.2 ml single tubes, 0.2 ml 12-strip tubes
Also for use with P100326
32 x 1.5 ml or 2ml tubes
Page 9 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Also for use with P600001
LightCycler capillaries and 0.5 ml tubes C
0.5/0.6 ml flip cap tube, LightCycler capillaries spin adapter
P100459 Plate Rack - RG
Special Adapter for Rotor-Gene GeneDisc (Corbett RotorGene and Qiagen RotorGeneQ) Fits to Adapters for 72-well and 100-well GeneDisk
Third Party Adapter (for 72-well (for 100-well GeneDisk Adapter GeneDisk) GeneDisk)
P100466 Plate Rack-1, SBS SmartCycler
Special Adapter for SmartCycler Plate
Third Party Adapter SmartCycler tubes (squid)
SmartCycler “Squid holder”
Page 10 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P100486 Plate Rack-2, SBS HG
Flat top high guides
Fits to Third Party Adapters (various)
please contact manufacturer
Example: NucleoMag adapter
P600006 Plate Rack-1 SBS 32 well Magna Pure
32-well Magna Pure plate Roche Plastic Ware Manufacturer: Roche
32-well MagnaPure plate
P600007 Plate Rack LC carousel V1
LightCycler Roche For 32-well LightCycler carousel.
P600024 Plate Rack LC carousel V2
LightCycler Roche For 32-well LightCycler carousel.
Page 11 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Adapters
P100326 Adapter SBS 32 Well U
Cooling adapter for 32 x 1.5 ml / 2 ml tubes including cap fixing mechanism for tubes with caps attached. (Picture shows cooling adapter P100326 in combination with lifter plate P600054)
P100515 Adapter SBS 96 well High
96-well cooling adapter high for all kind of non-skirted and half-skirted PCR plates, 0,2 ml PCR-tubes and stripes
P100516 Adapter SBS 96 well Low
96-well cooling adapter low for all kind of non-skirted and half-skirted PCR plates, 0,2 ml PCR-tubes and stripes
P600001 Adapter SBS 36 Well
LightCycler capillaries and 0,5 ml Tubes C
Page 12 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P600004 Adapter SBS 384 Well
For better cooling and positioning of 384-well PCR plates
P600063 Adapter SBS 96 well low universal
96-well cooling adapter (universal) for all kind of non-skirted, half-skirted and full-skirted PCR plates,0,2 ml PCR-tubes and stripes
Adapters P100326, P100515, P600001 are used with Plate Rack P100417 Adapters P100516, P600004 are used with Plate Rack P100318 or P100319
Page 13 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Tube Racks
P100323 Tube Rack 7 Well F
7 x 5ml tubes (please refer to Catalog order no:
P100324 Tube Rack 8 Well C
8 x 1.5ml tubes conical (P100487 can be used optional)
P100325 Tube Rack 28 Well C
28 x 0.2 ml tubes conical (For single PCR tubes, Stripes of 8 or 12 PCR tubes)
P100368 Tube Rack 8 Well F
8 x 2/ 0.5 ml tubes flat bt. (P100487 can be used optional)
P100369 Tube Rack 8 Well V
8 x 2 ml tubes V-bottom (P100487 can be used optional)
P600026 Tube Rack 11 Well
11 x 0.5/0.6 ml tubes conical (For 0,5 ml/0,6 ml PCR tubes)
Page 14 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P100395 Tube Rack 8 Well U Cooling
Adapter Universal cooling for 8 x 1.5 and 2 ml tubes (+ 0.5 ml free-standing tubes). Examples see below: (Note: Please check for availability of calibrated Rack/Tube combinations in PIRO software plates database) (Note: As plastic consumables may vary in dimensions slightly, please check accurate tube z-value setting and correct if necessary in PIRO software)
P100487 Tube Rack 8 Well U
Adapter Universal for 8 x1.5 and 2 ml tubes (+ 0.5 ml free-standing tubes). Examples see below: (Note: Please check for availability of calibrated Rack/Tube combinations in PIRO software plates database) (Note: As plastic consumables may vary in dimensions slightly, please check accurate tube z-value setting and correct if necessary in PIRO software)
P600011 Tube Rack 6 well, SBS sized rack
Adapter for 50 ml tubes and vials (flat bottom and conical bottom)
Page 15 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
P600014 Tube Rack 24 well, SBS sized rack
Adapter for primary tubes diameters in the range between 15 and 16.5 mm
P600023 Tube Rack 24 well, SBS sized rack
Adapter for primary tubes diameters in the range between 12 and 13 mm
P100371 Tube Rack 11 well C
For 0.5 / 0.6 ml tubes conical bottom. For example see below:
(Note: Please check accurate tube z-value and correct if necessary in PIRO software)
Page 16 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Waste Solutions
P100321 Waste Rack SBS
Tip rack and cover To be used in combination with a waste bag
P100322 Waste Channel 1
For tips 50 µl, 200 µl and 1000 µl For use with PIRO console and/or outside waste disposal
P100337 PIRO Console with drawer
Drawer-system for tip disposal (right side drawer) and storage for racks and adapters (left side drawer)
P600005 Waste box double-SBS
Waste box with extended volume (spanning two SBS positions)
Page 17 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
PIRO Additional Equipment
P100345 Barcode reader
Hand held scanner for 1-D barcodes (hand held scanner for 2-D barcodes available on request)
P600028 Tube rack adjust gauge
Teaching device for adjusting the bottom adjusting measure of tube rack P600011, P600014, P600023
P600054 Lifter Plate Flip-Cap 32 well
Lifter plate for use in combination with Adapter P100326 – (to raise tubes by 10 mm –for easier grabbing or closing of tubes)
Page 18 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Transport
V100527 Foamed material for secure transport
Replacement when original packaging of the PIRO has been lost
V100526 Packaging outer box
Replacement when original packaging of the PIRO has been lost
Service of the PIRO® Pipetting Head
P600041
Minor Service of the Pipetting
Head
The minor service of the pipetting head includes
the re-calibration of the pipetting head
the adjustment of the characteristic curve
exchange of sealing washers and O-ring gaskets
general cleaning of the pipetting head
P600042
Major Service of the Pipetting
Head
The major service of the pipetting head includes
the re-calibration of the pipetting head
the adjustment of the characteristic curve
exchange of sealing Washers and O-ring gaskets
general cleaning of the pipetting head
the potential exchange of the motor, spindles, and other hardware free of charge
optical refurbishment eg. replacement of optical scratched or damaged parts
P600043
Calibration Certificate
DIN EN ISO 8655 compliant certificate upon request (additional costs will be charged).
Rental of PIRO® Pipetting Heads
P600088
pipetting head rental 200 µl
P600089
pipetting head rental 1000 µl
P100314 Pipetting Head 200 1 μl - 200 μl P100315 Pipetting Head 1000 5 μl - 1000 μl Rentalperiod: 25 working days (from date of sending from DLTF ware house till date of arrival back at DLTF warehouse) Exceedance: In case of exceedance of the rental period additional costs will apply. Title of retention: Loaner item remains in the possession of DLTF throughout the entire loaning period.
Page 19 / 19
DORNIER-LTF GmbH
Rickenbacher Str. 107
88131 Lindau
Germany
Tel: +49 (0) 8382 2730 890
Fax: +49 (0) 8382 2730 8929
E-Mail: [email protected]
Web. www.dornier-ltf.com
Informations: Currency: All prices in EURO, excluding VAT / customs duties Delivery: EXW (Incoterms 2010) including packing General remark when using this Catalog as a reference. As plastic ware differs between manufacturers in shape as well as depth, the z-value might have to be adjusted. Depending on the shape of the plastic ware the calculation of the volumes may differ. Thus it is best to use consumables described in this document. For availability of particular tubes please check plate library in PIRO software.