Page 1 of 6
MARINE BUNKER SOLUTIONS
‘ZERO VERIFICATION CHECK’
BrightOil 666, IMO: 9661455
Verification By: Kyaw Myint Thein 24.07.2015, Singapore
Page 2 of 6
Arrived at Marina South Pier to go onboard for Brightoil 666. Reached Brightoil 666, and then started to
prepare for the fuel transfer to Gottfried Schute.
While onboard, the bunker meter seals were inspected, also saved a copy of the transmitter
configuration. No seals were broken and No configuration changes took place.
Front Seal at the Transmitter:
Sensor core Processor seal:
Page 3 of 6
Liquid Detector at Crane Boom Side:
Liquid Detector, Pressure Transmitter & Temperature Transmitter at Pump Side:
Page 4 of 6
Trend data leading up to verification test:
0
5
10
15
20
25
30
35
40
45
50
0
200
400
600
800
1000
1200
Density(kg/m³) Temperature(°C)
Dens
ity (k
g/m
Temperature(°C
)
0
1
2
3
4
5
6
7
8
9
10
0
20
40
60
80
100
120 Drive Gain(%) Pressure (bar)
Driv
e Ga
in (%
)Pressure (bar)
Page 5 of 6
Zero Verification Test:
Product was run for just over 1 hour to establish stable temperature and density. The flow was stopped
by closing of the isolation valves before and after the meter and opening of the bypass valve.
-0.3
-0.25
-0.2
-0.15
-0.1
-0.05
0
0.05
0.1
0.15
0.2
-0.3
-0.25
-0.2
-0.15
-0.1
-0.05
0
0.05
0.1
0.15
0.2Field Verification Zero(mT/hr) Live Zero(mT/hr)
Fiel
d Ve
rific
atio
n Ze
ro(m
T/hr
)Live Zero (m
T/hr)
-0.3
-0.25
-0.2
-0.15
-0.1
-0.05
0
0.05
0.1
0.15
0.2Live Zero(mT/hr)
Page 6 of 6
Meter Data: Sensor type: CMFHC3
Sensor Serial number: 12088611
Transmitter serial number: 25517794
Flow Calibration Factor: 7032.64.26
Manual Zero: 0.03284 µs
Conclusion: The zero verification test show 0.0494 mt/hr (49.4 kg/hr) under the following conditions:
Live Zero test average API Density Temperature Pressure 0.0494 mT/hr 976.36 kg/m3 33.02°C 5.82 bar
This model meter has a specified zero stability limit of 240 kg/hr: Test Pass Fail