To reduce the risk of electric shock and fire, do not remove the cover of this device. Thereare no user serviceable parts inside. Please refer all servicing to licensed service technicians.
The international symbol of a lightning bolt inside a triangle is intended to alert the user touninsulated “dangerous voltage” within the device’s enclosure. The international symbol of anexclamation point inside a triangle is intended to alert the user to the presence of importantoperating, maintenance and servicing information in the manual accompanying the device.
To prevent electrical shock, match wide blade of plug to wide slot, fully insert.
To reduce the risk of electrical shock, do not expose this equipment to rain or moisture.
To reduce the risk of electrical shock, ensure the voltage selector switch is selected to theappropriate supply voltage.
To reduce the risk of electrical shock, ensure the fuses are replaced with the appropriatefuse according to the unit markings.
1. Read Instructions—All safety and operating instructionsshould be read before operating the device.
2. Retain Instructions—The safety and operatinginstructions should be retained for future reference.
3. Heed Warnings—All warnings on the device and in theoperating instructions should be adhered to.
4. Follow Instructions—All operating and safety instructionsshould be followed.
5. Water & Moisture—The device should never be used in,on or near water for risk of fatal shock.
6. Carts & Stands—The device should only be used on cartsor stands recommended by the manufacturer.
7. Ventilation—The device should always be located in sucha way that it maintains proper ventilation. It should neverbe placed in a built-in installation or anywhere that mayimpede the flow of air through its ventilation slots.
8. Heat—Never locate the device near heat sources such asradiators, floor registers, stoves or other heat-generatingdevices.
9. Power Cord Protection—Power cables should be routedso they are not likely to be stepped on or crushed by itemsplaced on them or against them. Special attention shouldbe paid to areas where the plug enters a socket or fusedstrip and where the cord exits the device.
10. Cleaning—The device should be cleaned in accordancewith manufacturer’s instructions.
11. Periods Of Non-Use—The device should be unpluggedwhen not being used for extended periods.
12. Dangerous Entry—Care should be taken that no foreignobjects or liquids fall or are spilled inside the device.
13. Damage Requiring Service—The device should beserviced by licensed technicians when:
• The plug or power supply cord has been damaged.
• Objects have fallen or liquid has spilled inside the device.
• The device has been exposed to moisture.
• The device does not appear to be operating properly orexhibits a marked change in performance.
• The device has been dropped or the enclosure becomesdamaged.
14. Service—The device should always be serviced bylicensed technicians. Only replacement parts specified bythe manufacturer should be used. The use of unauthorizedsubstitutions may result in fire, shock, or other hazards.
15. Do not position the equipment so that it is difficult tooperate the disconnecting device (power cord).
16. If the equipment is used in a manner not specified bythe manufacturer, the protection provided by theequipment may be impaired.
18. Some of the units in this series are heavierthan 18 kg (39.7 lb). Use safe practices when lifting.
17. It is recommended that component power switchremains in the “off” position when connecting ordisconnecting from a Bryston Isolation Transformer.
CAUTION
≥32 kg (70.5 lb) ≥55 kg (121.2 lb)
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Bryston PIUs (Power Isolation Units) combine the best surge
suppression with unique toroidal transformer technologies
from PLITRON to provide the ultimate in AC power
conditioning and protection for sensitive audio and video
equipment applications.
PIUs use ZeroSurge patented series-mode surge removal
filters to absorb dangerous voltage surges and safely dissipate
them without using failure-prone MOVs (metal oxide
varistors). Also, unlike MOV-based protection, voltage surges
are not shunted to ground.
Isolation is combined with proven proprietary technologies
from PLITRON in the over-sized toroidal transformer. NBT
works as a low pass filter using the controlled leakage
inductance and capacitances within the transformer to cancel
common mode and differential mode noise. LoNo technology
has been used for years by high-end audio companies who
demand silent transformers. Imin technology reduces inrush
currents. UST provides additional common mode filtering
using a highly efficient faraday screen.
Low-impedance output with balanced high-power primary
input provides the most unconstrained, yet protected, energy
source available to your equipment.
Description
Please keep the original shipping box and all packingmaterial.
This will ensure the PIU is protected in future transport.
In the unlikely event you have a problem andmust return it for
service youmust use the proper packingmaterial.
Ship the PIU only in the original packingmaterial, as the unit is
not insurable by carriers otherwise.
Shipping Carton & Packing Material
Bryston Power PIUs are extremely efficient devices, however,
they are also very high-power devices, and must be
adequately cooled.
Do not install the PIU directly above heat-generating
equipment.
Maintain at least 15cm behind the PIU for adequate wiring
space.
PIUs have ventilation slots on the base, side panels and the
cover. Maintain at least 2.5cm distance from each of these
surfaces to anything else. Should your installation conditions
be constricted, additional forced air-cooling may be
necessary.
Placement & Ventilation
Bryston BIT power isolation products are warranted to be free
from manufacturing defects for a minimum of five years from
the original date of sale. This includes parts, labour and return
shipping to the first registered owner and all subsequent
registered owners. Warranty coverage is extended to
applicable products registered or having proof-of-purchase
(sales invoice, etc.).
In the event of a defect or malfunction, BIT Power will remedy
the problem by repair or replacement, as we deem necessary,
to restore the product to full performance.
This warranty is considered void if the defect, malfunction or
failure of the product or any component part was caused by
damage (not resulting from a defect or malfunction) or abuse
while in the possession of the customer. Failure to fully comply
with BIT Power operating instructions, voids the warranty.
Warranty
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Front Panel Layout
Electrical SpecificationsInput Voltage
Nominal
VAC120 , 60Hz
Range +/- 10% voltage
57-63Hz
Model Number
BIT-5
Input
Current
Limiting
5.0A
Circuit Breaker
Front Panel
Input Current
Rating
(see note above)
5.0A
½ cycle
50A
Load Current Capability
1 second
40A
10 seconds
15A
The front panel power switch is also
a circuit breaker. As a circuit breaker,
it prevents excessive current from
entering the PIU.
When the power is on, the switch is
illuminated. When the breaker trips,
the switch returns to its “off”
position.
Circuit Protection
Bryston PIUs will shut-down if
internal unit temperature reaches
excessive levels.
Thermal Protection
Per UL, CSA and National Electrical
codes, devices with line cords and
plugs must not consume more than
80% of a branch circuit’s rating.
While Bryston Power Isolation Units
are designed to handle well beyond
these limits, they must be marked
with a maximum input current that
satisfies the requirements.
Input Current Rating
(Torus CS-5-S)
BIT-5 OWNER’S MANUAL
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Mechanical SpecificationsWeight
13.5 kg
13.0 kg
Size, mm
(w x d x h)
483 x 286 x 102
483 x 268 x 105
Model Number
BIT-5
Height includes removable rubber mounting feet.
Input
Connector
(Rear Panel)
IEC 15A
Inlet
Line Cord
(included)
N5/15, 14AWG
C13, 15A/125V
Suggested
Wall
Receptacle
Standard outlet
NEMA 5-15R
15A - 125V
Output
Connector
(Rear Panel)
Qty 3 (6 outlets)
Medical-grade
Bryston PIUs are high-power
products. The outlets they are
plugged into should be sufficient to
provide the current to operate them
without tripping circuit breakers
within your junction panel.
Rear Panel Layout
Wall ReceptaclesAccessoryGround Stud
Power Inlet
Power Outlet
Removable MountingFeet for Rack Mount
Line Cords
Standard 15A 120V
IEC C135 15P, Straight Blade, 2 pole,
3-wire grounding, 15A 125V3 x 14AWG2.5 m
Equipment end:Plug: -
Cord:Length:
Product Label
Warning Label
Single 5.0A
Model Numbers BIT-5,
WARNINGDISCONNECT POWERBEFORE WORKING WITHIN
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Mechanical SpecificationsWeight
20.2 kg
Size, mm
(w x d x h)
483 x 268 x 105
Model Number
BIT15-17-SIL
(Torus CS 15 S)
Height includes removable rubber mounting feet.
Input
Connector
(Rear Panel)
IEC-320 c14
Inlet
Line Cord
(included)
N5/15, 14AWG
C13, 15A/125V
Suggested
Wall
Receptacle
Standard outlet
NEMA 5-15R
15A - 125V
Output
Connector
(Rear Panel)
Qty 5 (10 outlets)
Medical-grade
duplex 15A
Bryston Isolation Transformers are
high-power products. The outlets
they are plugged into should be
sufficient to provide the current to
operate them without tripping circuit
breakers within your junction panel.
Wall Receptacles
AccessoryGround Stud
Power Inlet
Power Outlet
Removable MountingFeet for Rack Mount
Line Cords
Standard 15A 120V
IEC C135 15P, Straight Blade, 2 pole,
3-wire grounding, 15A 125V3 x 14AWG2.5 m
Equipment end:Plug: -
Cord:Length:
Toronto,Canada
www.TorusPower.com
Model Number
InputOutput
Part Number
Serial Number
RM 2.5
120VAC 60Hz, 2.5A max120V 2.5A max
PA-10201-00
0001
WARNINGDISCONNECT POWERBEFORE WORKING WITHIN
Warning Label
Single 15.0A
Model Numbers BIT15-17-SIL
(Toros CS 15 S),
Rear Panel Layout
Product LabelBIT power isolation unitsare made for Bryston byPlitron Mfg Inc., Toronto,Ontario, Canada underthe Torus brand.
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Mechanical SpecificationsModel Number
BIT20-BAL-17-SIL(Torus CS 20 BAL S)
(Torus CS 20 S)BIT20-17-SIL
Input
Connector
(Rear Panel)
IEC-320 C20
IEC-320 C20
Line Cord
(included)
N6/15, 14AWG
C19, 15A/250V
N5/20, 12AWG
C19, 20A/125V
Suggested
Wall
Receptacle
NEMA 6-15R
15A - 250V
NEMA 5-20R
20A - 125V
Output
Connectors
(Rear Panel)
Qty 5 (10 outlets)
Medical-grade
duplex 20A
Qty 5 (10 outlets)
Medical-grade
duplex 20A
Weight
39.5kg
42.2kg
Size mm
(w x d x h)
432 x 402 x 162
432 x 402 x 162
Bryston Isolation Transformers are
high-power products. The outlets
they are plugged into should be
sufficient to provide the current to
operate them without tripping circuit
breakerswithin your junction panel.
D e d i c a t e d c i r c u i t s a r e
recommended. Balanced input
products, 240VAC, require dual
120V phases (2 pole, 3-wire). Wall
outlets for 240VAC are rated at 250V
and will likely require special
installation. Dedicated outlets, or
any household or facility wiring
should be installed by a licenced
electrician to local codes.
Pictured below are suggested
receptacle types for installation.
Rear Panel Layout Wall Receptacles
NEMA 6-15Rfor Balanced 20A unit
NEMA 5-20Rfor Single 20A unit
Balanced 20A, Model Numbers BIT20-BAL-17-SIL,
Product Label
Power Inlet
AccessoryGround Stud
20A Medical-Grade Outlet
Single 20A, Model Numbers BIT20-17-SIL,
Line Cords
Standard 15A 240/208V
Used on:Equipment end:Plug:
Cord:Length:
Model Numbers BIT20-BAL,IEC C19
6-15P, Straight Blade, 2 pole,3-wire grounding, 15A 250V
3 x 14AWG2.5 m
Standard 20A 120V
Used on:Equipment end:Plug:
Cord:Length:
Model Numbers BIT20,IEC C19
5-20P, Straight Blade, 2 pole,3-wire grounding, 20A 125V
3 x 12AWG2.5 m
BIT power isolation units aremade for Bryston by PlitronMfg Inc., Toronto, Ontario,Canada under the Torusbrand.
www.bryston.comB I T Power Isolation Units Owner's Manual· ·
Specifications subject to change without notice.
www.bryston.com
Bryston Ltd.677 Neal DriveP.O. Box 2170, Stn. MainPeterborough, OntarioCanada K9J 7Y4
For sales
In Canada: James Tanner
Phone: 705-742-5325
in the USA: Craig Bell,
Phone: 626-355-9525
For service & technical information:
In Canada:
Phone: 705-742-5325
In the USA:
Phone: 802-334-1201
POWER ISOLATION UNITS
300027-3 2012-02-21