B Commands
• bandwidth (if_manager), on page 3• bandwidth (if_manager), on page 4• bandwidth (qosmgr), on page 5• bandwidth (svi), on page 6• bandwidth (tm), on page 7• banner motd, on page 8• bcm-shell module (syscli), on page 9• bcm-shell module (syscli), on page 10• beacon, on page 11• bestpath, on page 12• bfd-app session auto-expiry, on page 13• bfd-app session remove, on page 14• bfd-app session src-ip, on page 15• bfd (bgp_bfd), on page 16• bfd (eigrp_bfd), on page 17• bfd (isis_bfd), on page 18• bfd (ospf_bfd), on page 19• bfd authentication key-id, on page 20• bfd echo, on page 21• bfd echo-interface, on page 22• bfd interval min_rx multiplier, on page 23• bfd ipv4, on page 24• bfd move-session target, on page 25• bfd neighbor src-ip, on page 26• bfd optimize subinterface, on page 27• bfd per-link, on page 28• bfd session-store remove client, on page 29• bfd session-store source-ip dest-ip intf client, on page 30• bfd session state state, on page 31• bfd slow-timer, on page 32• blink, on page 33• bloggerd delete, on page 34• bloggerd live-process-core process pid, on page 35
B Commands1
• bloggerd live-process-core sap, on page 36• bloggerd log-dump, on page 37• bloggerd log-dump once log-buffer sap event-history, on page 38• bloggerd log-dump once pss uuid, on page 39• bloggerd log-throttle, on page 40• bloggerd log-transfer, on page 41• bloggerd mleak-check directory1 directory2, on page 42• bloggerd mleak-dump all, on page 43• bloggerd parse log-buffer, on page 44• bloggerd parse log-buffer file sap, on page 45• bloggerd parse pss file, on page 46• boot, on page 47• boot-install nxos, on page 48• boot-order, on page 49• boot auto-copy, on page 50• boot nxos (bootvar), on page 51• boot nxos (bootvar), on page 52• bootmode boot, on page 53• bootmode extruntime, on page 54• bootmode hitless, on page 55• bootmode module, on page 56• bootmode nodiagruntime, on page 57• bootmode runtime, on page 58• buffer-boost, on page 59
B Commands2
B Commands
bandwidth (if_manager)bandwidth {bandwidth_val|inherit [inherit_val]}|no bandwidth {[bandwidth_val]|inherit [inherit_val]}
Syntax Description Negate a command or set its defaultsno
Set bandwidth informational parameterbandwidth
Type: integer
min: 1 max: 800000000
Bandwidth in kilobits
bandwidth_val
Specify that bandwidth is inheritedinherit
Type: integer
min: 1 max: 800000000
Bandwidth in kilobits
inherit_val
Type: integer
min: 1 max: 80000000
Bandwidth in kilobits
inherit_val
Command Modes • /exec/configure/if-eth-port-channel• /exec/configure/if-port-channel-range• /exec/configure/if-port-channel-sub• /exec/configure/if-eth-port-channel-switch• /exec/configure/if-eth-port-channel-p2p• /exec/configure/if-eth-port-channel• /exec/configure/if-port-channel-range• /exec/configure/if-port-channel-sub• /exec/configure/if-eth-port-channel-switch• /exec/configure/if-eth-port-channel-p2p
B Commands3
B Commandsbandwidth (if_manager)
bandwidth (if_manager)bandwidth {bandwidth_val|inherit [inherit_val]}|no bandwidth {[bandwidth_val]|inherit [inherit_val]}
Syntax Description Negate a command or set its defaultsno
Set bandwidth informational parameterbandwidth
Type: integer
min: 1 max: 100000000
Bandwidth in kilobits
bandwidth_val
Specify that bandwidth is inheritedinherit
Type: integer
min: 1 max: 100000000
Bandwidth in kilobits
inherit_val
Command Modes • /exec/configure/if-ethernet-all• /exec/configure/if-eth-non-member• /exec/configure/if-ether-sub• /exec/configure/if-gig-ether-sub• /exec/configure/if-remote-ethernet-sub• /exec/configure/if-ether-sub-p2p
B Commands4
B Commandsbandwidth (if_manager)
bandwidth (qosmgr)[no] bandwidth {{xxx bw-value [{bps|kbps|mbps|gbps}]|percent percentage}|remaining percentrem-perc}
Syntax Description Negate a command or set its defaultsno
Specify bandwidth for the classbandwidth
xxx Not available in this release.xxx
Type: long
Value in bps/kbps/mbps/gbps
bw-value
Bits per secondbps
Kilo bits per secondkbps
Mega bits per secondmbps
Giga bits per secondgbps
Percentage of available bandwidthpercent
Type: uinteger
min: 0 max: 100
Value in percentage
percentage
% of remaining bandwidthremaining
Type: uinteger
min: 0 max: 100
Value in percentage
rem-perc
Command Modes • /exec/configure/policy-map/type/queuing/class
B Commands5
B Commandsbandwidth (qosmgr)
bandwidth (svi)bandwidth bandwidth_val|no bandwidth
Syntax Description Negate a command or set its defaultsno
Set bandwidth informational parameterbandwidth
Type: uinteger
min: 1 max: 400000000
Bandwidth in kilobits
bandwidth_val
Command Modes • /exec/configure/if-vlan-common
B Commands6
B Commandsbandwidth (svi)
bandwidth (tm)bandwidth bandwidth_val|no bandwidth
Syntax Description Negate a command or set its defaultsno
Set bandwidth informational parameterbandwidth
Type: uinteger
min: 1 max: 10000000
Bandwidth in kilobits
bandwidth_val
Command Modes • /exec/configure/if-any-tunnel
B Commands7
B Commandsbandwidth (tm)
banner motdbanner motd line|no banner motd
Syntax Description Negate a command or set its defaultsno
Configure banner messagebanner
Configure banner motd messagemotd
Type: remainder
Delimiter char (Very first char is delimiter char) followed by message ending with delimiter
line
Command Modes • /exec/configure
B Commands8
B Commandsbanner motd
bcm-shell module (syscli)bcm-shell module module
Syntax Description bcm shell/cmdbcm-shell
Module number of thelinecard
module
Type: integer
Enter module number
module
Command Modes • /exec
B Commands9
B Commandsbcm-shell module (syscli)
bcm-shell module (syscli)bcm-shell module module quoted-cmd
Syntax Description bcm shell/cmdbcm-shell
Module number of the linecardmodule
Type: integer
Enter module number
module
Type: string
the command to run on bcm-shell
quoted-cmd
Command Modes • /exec
B Commands10
B Commandsbcm-shell module (syscli)
beacon[no] beacon
Syntax Description Negate a command or set its defaultsno
Disable/enable the beacon for an interfacebeacon
Command Modes • /exec/configure/if-ethernet-all• /exec/configure/if-eth-base
B Commands11
B Commandsbeacon
bestpath[no] bestpath {always-compare-med|med{missing-as-worst|non-deterministic|confed}|compare-routerid|cost-community ignore|as-pathmultipath-relax|multipath compare-neighborid}
Syntax Description Negate a command or set its defaultsno
Change default bestpath selection algorithmbestpath
Compare MED on paths from different ASalways-compare-med
MEDmed
Treat missing MED as highest MEDmissing-as-worst
Not always pick the best-MED path among paths from same ASnon-deterministic
Compare router-id for identical EBGP pathscompare-routerid
cost communitycost-community
Ignore cost communities in bestpath selectionignore
Compare MED only from paths originated from within a confederationconfed
AS-Pathas-path
Relax AS-Path restriction when choosing multipathsmultipath-relax
Influence multipath selection algorithmmultipath
Whenmore paths available than max path config, use neighborid tibreakercompare-neighborid
Command Modes • /exec/configure/router-bgp/vrf-cmds
B Commands12
B Commandsbestpath
bfd-app session auto-expirybfd-app session auto-expiry {timeout millis|now}
Syntax Description BFD application commandsbfd-app
auto expiry start/endauto-expiry
session operationsession
timeout aftertimeout
expiry reached, dont wait to timeout, do them nownow
Type: integer
milli-secs later
millis
Command Modes • /exec/configure
B Commands13
B Commandsbfd-app session auto-expiry
bfd-app session removebfd-app session remove {all|intf intf_id|iod iod_id}
Syntax Description BFD application commandsbfd-app
session operationsession
Remove sessionsremove
Remove all sessionsall
Remove all sessions on interfaceintf
Type: interface
Interface Id
intf_id
interface iodiod
Type: hex
Interface iod in hex
iod_id
Command Modes • /exec/configure
B Commands14
B Commandsbfd-app session remove
bfd-app session src-ip[no] bfd-app session src-ip {src_ip dest-ip dest_ip|src_ipv6 dest-ip dest_ipv6} {intf intf_id|iodiod_id}
Syntax Description Negate a command or set its defaultsno
BFD application commandsbfd-app
session operationsession
Source ipsrc-ip
Type: ipaddr
Source ip value
src_ip
Type: ipv6addr
Source ipv6 value
src_ipv6
Destination ipdest-ip
Type: ipaddr
Destination ip value
dest_ip
Type: ipv6addr
Destination ipv6 value
dest_ipv6
interface iodiod
Type: hex
Interface iod in hex
iod_id
interfaceintf
Type: interface
Interface Id
intf_id
Command Modes • /exec/configure
B Commands15
B Commandsbfd-app session src-ip
bfd (bgp_bfd)[{no|default}] bfd
Syntax Description Negate a command or set its defaultsno
Inherit values from a peer templatedefault
Bidirectional Fast Detection for the neighborbfd
Command Modes • /exec/configure/router-bgp/router-bgp-neighbor-sess
B Commands16
B Commandsbfd (bgp_bfd)
bfd (eigrp_bfd)[no] bfd
Syntax Description Negate a command or set its defaultsno
Enable BFD on all EIGRP interfacesbfd
Command Modes • /exec/configure/router-eigrp• /exec/configure/router-eigrp/router-eigrp-vrf• /exec/configure/router-eigrp/router-eigrp-af-ipv4
B Commands17
B Commandsbfd (eigrp_bfd)
bfd (isis_bfd)[no] bfd
Syntax Description Negate a command or set its defaultsno
Enable IPv4 BFD on all ISIS interfacesbfd
Command Modes • /exec/configure/router-isis/router-isis-vrf-common• /exec/configure/router-isis/router-isis-af-ipv4
B Commands18
B Commandsbfd (isis_bfd)
bfd (ospf_bfd)[no] bfd
Syntax Description Negate a command or set its defaultsno
Enable BFD on all OSPF interfacesbfd
Command Modes • /exec/configure/router-ospf• /exec/configure/router-ospf/vrf
B Commands19
B Commandsbfd (ospf_bfd)
bfd authentication key-id[no] bfd authentication auth_name key-id key_id_val {key key_val|hex-key h_key_val}|no bfdauthentication
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Configure BFD authentication parametersauthentication
auth algorithm
Keyed-SHA1 value: 20Keyed-SHA1
auth_name
Key ID to use in BFD frameskey-id
Type: integer
min: 1 max: 255
Key ID value
key_id_val
ASCII SHA1 secretkey
HEX binary SHA1 secrethex-key
Type: string
length: 20
SHA1 secret value
key_val
Type: string
length: 40
SHA1 secret value. e.g ABCD123
h_key_val
Command Modes • /exec/configure/if-ma• /exec/configure/if-vlan-common• /exec/configure/if-ma-p2p
B Commands20
B Commandsbfd authentication key-id
bfd echo[no] bfd echo
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Configure Echo function for sessionsecho
Command Modes • /exec/configure/if-ma• /exec/configure/if-vlan-common• /exec/configure/if-ma-p2p
B Commands21
B Commandsbfd echo
bfd echo-interface[no] bfd echo-interface ifindex
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Configure interface used for bfd echo framesecho-interface
Type: interface
loopback interface
ifindex
Command Modes • /exec/configure
B Commands22
B Commandsbfd echo-interface
bfd interval min_rx multiplier[no] bfd interval min_tx_mills min_rx min_rx_mills multiplier int_mult
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Configure BFD session interval parametersinterval
Type: integer
min: 50 max: 999
TX interval in milliseconds
min_tx_mills
Minimum RX intervalmin_rx
Type: integer
min: 50 max: 999
RX interval in milliseconds
min_rx_mills
Configure detect multiplier for bfd sessionsmultiplier
Type: integer
min: 1 max: 50
Detect Multiplier
int_mult
Command Modes • /exec/configure• /exec/configure/if-ma• /exec/configure/if-ma-p2p
B Commands23
B Commandsbfd interval min_rx multiplier
bfd ipv4[no] bfd ipv4
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Enable/Disable IPv4 sessionsipv4
Command Modes • /exec/configure/if-ma• /exec/configure/if-vlan-common• /exec/configure/if-ma-p2p
B Commands24
B Commandsbfd ipv4
bfd move-session targetbfd move-session target target_mod
Syntax Description BFDcommandsbfd
move a sessionmove-session
Target moduletarget
Type: integer
min: 1 max: 18
Module number
target_mod
Command Modes • /exec/configure/if-ma• /exec/configure/if-ma-p2p
B Commands25
B Commandsbfd move-session target
bfd neighbor src-ip[no] bfd neighbor src-ip {src_ip dest-ip dest_ip|src_ipv6 dest-ip dest_ipv6}
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
BFD neighbor configuration commands (simulate client)neighbor
Source ipsrc-ip
Type: ipaddr
Source ip value
src_ip
Type: ipv6addr
Source ipv6 value
src_ipv6
Destination ipdest-ip
Type: ipaddr
Destination ip value
dest_ip
Type: ipv6addr
Destination ipv6 value
dest_ipv6
Command Modes • /exec/configure/if-ma• /exec/configure/if-ma-p2p
B Commands26
B Commandsbfd neighbor src-ip
bfd optimize subinterface[no] bfd optimize subinterface
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
optimizeoptimize
optimize subinterfacessubinterface
Command Modes • /exec/configure/if-eth-port-channel• /exec/configure/if-ethernet• /exec/configure/if-ether-p2p• /exec/configure/if-eth-port-channel-p2p
B Commands27
B Commandsbfd optimize subinterface
bfd per-link[no] bfd per-link
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Run BFD sessions on each port-channel linkper-link
Command Modes • /exec/configure/if-eth-port-channel• /exec/configure/if-port-channel-sub• /exec/configure/if-eth-port-channel-p2p;
B Commands28
B Commandsbfd per-link
bfd session-store remove clientbfd session-store remove hex_disc client int_cl
Syntax Description BFD commandsbfd
session store operationsession-store
Remove session from session storeremove
Type: hex
Session discriminator
hex_disc
Client Idclient
Type: integer
client
int_cl
Command Modes • /exec/configure
B Commands29
B Commandsbfd session-store remove client
bfd session-store source-ip dest-ip intf clientbfd session-store source-ip src_ip dest-ip dest_ip intf intf_id client int_cl
Syntax Description BFD commandsbfd
Session storeoperation
session-store
source ipsource-ip
Type: ipaddr
source ip value
src_ip
dest ipdest-ip
Type: ipaddr
source ip value
dest_ip
interfaceintf
Type: interface
Interface Id
intf_id
Client Idclient
Type: integer
client
int_cl
Command Modes • /exec/configure
B Commands30
B Commandsbfd session-store source-ip dest-ip intf client
bfd session state statebfd session state hex_disc state state_up_down
Syntax Description BFD commandsbfd
session related testsession
Change session statestate
Type: hex
Sessiondiscriminator
hex_disc
Change to statestate
UP/DOWN
up value: 4session up
down value: 3session down
state_up_down
Command Modes • /exec/configure
B Commands31
B Commandsbfd session state state
bfd slow-timer[no] bfd slow-timer int_slow_timer
Syntax Description Negate a command or set its defaultsno
BFD commandsbfd
Configure slowmode timer for sessionsslow-timer
Type: integer
min: 1000 max: 30000
Slow rate timer in milliseconds
int_slow_timer
Command Modes • /exec/configure
B Commands32
B Commandsbfd slow-timer
blink[no] blink {module module|s0 santa-cruz-range|chassis|powersupply psnum|fan fan_num}
Syntax Description Negate a command or set its defaultsno
blink locator ledblink
blink module ledmodule
Type: integer
please enter the module number
module
Type: xbar-str
blink a specific xbar
s0
Type: integer
please enter the xbar number
santa-cruz-range
blink chassis ledchassis
blink powersupply ledpowersupply
Type: uinteger
min: 1 max: 10
powersupply number
psnum
blink Fan ledfan
Type: uinteger
min: 1 max: 12
fan number
fan_num
Command Modes • /exec
B Commands33
B Commandsblink
bloggerd deletebloggerd delete {all-temporary-binary-log-dumps|all-temporary-binary-show-tech-files}
Syntax Description Blogger commandsbloggerd
Delete all logs of one typedelete
Delete all binary log dumps from the local partition(/var/sysmgr/tmp/)
all-temporary-binary-log-dumps
Delete all binary show tech filesall-temporary-binary-show-tech-files
Command Modes • /exec
B Commands34
B Commandsbloggerd delete
bloggerd live-process-core process pidbloggerd live-process-core process process-name pid process-pid
Syntax Description Blogger commandsbloggerd
Request a process core dump without killing itlive-process-core
Linux Process nameprocess
Type: string
Enter the Linux name of the process for which core is being requested (Eg: sysmgr)
process-name
Process PIDpid
Type: integer
Enter the linux PID of the process for which core is being requested (Eg: 4571)
process-pid
Command Modes • /exec
B Commands35
B Commandsbloggerd live-process-core process pid
bloggerd live-process-core sapbloggerd live-process-core sap sap
Syntax Description Blogger commandsbloggerd
Dump the core of the live-processlive-process-core
Dump core for a particular SAPsap
Type: integer
min: 0 max: 65536
Enter a valid SAP. Enter 0 for ALL SAPs in this VDC
sap
Command Modes • /exec
B Commands36
B Commandsbloggerd live-process-core sap
bloggerd log-dump[no] bloggerd log-dump {all|[module module] sap sap_num [{vdc new_id|vdc-all}]}
Syntax Description Negate a command or set its defaultsno
Blogger commandsbloggerd
Dump Log Bufferlog-dump
Log Dump for ALL services across ALLmodules in the switch on reaching thresholdall
Enable Buffer Dump for particular Modulemodule
Type: integer
Enter a valid Module Number
module
Enable Buffer Dump for a particular sapsap
Type: integer
min: 0 max: 65536
Enter a valid SAP. Enter 0 for ALL SAPs in this VDC
sap_num
Enable Log Dump for a particular VDC. DEFAULT_VDC by defaultvdc
Type: integer
Enter a valid VDC ID
new_id
Enable Log Dump for the sap on ALL VDCsvdc-all
Command Modes • /exec/configure
B Commands37
B Commandsbloggerd log-dump
bloggerd log-dump once log-buffer sap event-historybloggerd log-dump once log-buffer sap sap event-history {errors|msgs|app-specific uuid instancebuffer-instance}
Syntax Description Blogger commandsbloggerd
Dump Log Bufferlog-dump
Dump Log Buffer once immediatelyonce
Dump Log bufferlog-buffer
Enable Buffer Dump for a particular sapsap
Type: integer
min: 0 max: 65536
Enter a valid SAP. Enter 0 for ALL SAPs in this VDC
sap
Event-History Buffersevent-history
event-history errorserrors
event-history messagesmsgs
application specific event historyapp-specific
Type: integer
Enter valid app's UUID
uuid
Buffer Instance of the App-Specific SDWrap bufferinstance
Type: integer
Enter a valid SDWrap buffer instance for the app
buffer-instance
Command Modes • /exec
B Commands38
B Commandsbloggerd log-dump once log-buffer sap event-history
bloggerd log-dump once pss uuidbloggerd log-dump once pss uuid uuid
Syntax Description Blogger commandsbloggerd
Dump Log Bufferlog-dump
DumpLogBuffer once immediatelyonce
Dump PSSpss
Dump PSS for a particular UUIDuuid
Type: integer
min: 0 max: 65536
Enter a app's UUID
uuid
Command Modes • /exec
B Commands39
B Commandsbloggerd log-dump once pss uuid
bloggerd log-throttle[no] bloggerd log-throttle [min-rollover min-rollover max-rollover-per-minutemax-rollover-per-minute]
Syntax Description Negate a command or set its defaultsno
Blogger commandsbloggerd
Enable Log Dump Throttling for all NxOS serviceslog-throttle
Number of minimum buffer rollovers before starting to throttle. Default: 5min-rollover
Type: integer
min: 1 max: 1000
Enter the mininum number of roll-overs before throttleing log-dump. Default:5
min-rollover
Maximum allowed buffer rollovers per minute. Default: 1max-rollover-per-minute
Type: integer
min: 1 max: 100
Enter the maximum allowed roll-overs per minute before throttling. Default: 1
max-rollover-per-minute
Command Modes • /exec/configure
B Commands40
B Commandsbloggerd log-throttle
bloggerd log-transferbloggerd log-transfer {ip-addr path|logflash}
Syntax Description Blogger commandsbloggerd
Configure log transferlog-transfer
Type: ipaddr
IP addr of logging server
ip-addr
Type: string
Path in tftp server to store logs. Eg: logOutput
path
Move all log-files to logflashlogflash
Command Modes • /exec/configure
B Commands41
B Commandsbloggerd log-transfer
bloggerd mleak-check directory1 directory2bloggerd mleak-check directory1 uri0 directory2 uri1
Syntax Description Blogger commandsbloggerd
Leak checkmleak-check
Enter path of directorydirectory1
Type: string
Linux path to file/directory (Eg: /bootflash/abc)
uri0
Enter path of directorydirectory2
Type: string
Linux path to file/directory (Eg: /bootflash/abc)
uri1
Command Modes • /exec
B Commands42
B Commandsbloggerd mleak-check directory1 directory2
bloggerd mleak-dump allbloggerd mleak-dump all
Syntax Description Blogger commandsbloggerd
Leak dumpmleak-dump
All apps on allmodules
all
Command Modes • /exec
B Commands43
B Commandsbloggerd mleak-dump all
bloggerd parse log-bufferbloggerd parse log-buffer {file|directory} uri0
Syntax Description Blogger commandsbloggerd
Parse a fileparse
Parse buffer log filelog-buffer
Enter path of directorydirectory
Enter file name. Please unzip file before parsing!file
Type: string
Linux path to file/directory (Eg: /bootflash/abc)
uri0
Command Modes • /exec
B Commands44
B Commandsbloggerd parse log-buffer
bloggerd parse log-buffer file sapbloggerd parse log-buffer file uri0 sap sap-num
Syntax Description Blogger commandsbloggerd
Parse a fileparse
Parse buffer log filelog-buffer
Enter file name. Please unzip file before parsing!file
Type: string
Linux path to file (Eg: /bootflash/abc)
uri0
SAP of the application which should parse the filesap
Type: integer
min: 0 max: 65536
Enter a valid SAP. Enter 0 for ALL SAPs in this VDC
sap-num
Command Modes • /exec
B Commands45
B Commandsbloggerd parse log-buffer file sap
bloggerd parse pss filebloggerd parse pss file uri0
Syntax Description Blogger commandsbloggerd
Parse a fileparse
Parse a dumped PSS Filepss
Enter file name (without pss extensions). Please unzip file before parsing!file
Type: string
Linux path to file/directory (Eg: /bootflash/abc)
uri0
Command Modes • /exec
B Commands46
B Commandsbloggerd parse pss file
bootboot s0 uri0 [module [module]]|no boot s0 [uri0 [module [module]]]
Syntax Description Negate a command or set its defaultsno
Configure boot variablesboot
Type: bootvar
use [show boot variables] for list of keywords
s0
Type: uri
Enter module image uri
uri0
Enter module number for the imagemodule
Type: integer
Enter module number
module
Command Modes • /exec/configure
B Commands47
B Commandsboot
boot-install nxosboot-install nxos uri0|no boot-install nxos [uri0]
Syntax Description Negate a command or set its defaultsno
Configure boot variablesboot-install
Configure NXOS imagenxos
Type: uri
Enter NXOS image uri
uri0
Command Modes • /exec/configure
B Commands48
B Commandsboot-install nxos
boot-orderboot-order new_id
Syntax Description The order at which a vdc will boot up. VDCs at the same level will be started parallelyboot-order
Type: integer
The order at which a vdc will boot up. VDCs at the same level will be started parallely
new_id
Command Modes • /exec/configure/vdc
B Commands49
B Commandsboot-order
boot auto-copy[no] boot auto-copy
Syntax Description Negate a command or set its defaultsno
Configure boot variablesboot
Turns on/off autocopy of bootvar imagesauto-copy
Command Modes • /exec/configure
B Commands50
B Commandsboot auto-copy
boot nxos (bootvar)boot nxos uri0 [[sup-1] [sup-2]]|no boot nxos [uri0 [[sup-1] [sup-2]]]
Syntax Description Negate a command or set its defaultsno
Configure boot variablesboot
Configure NXOS imagenxos
Type: uri
Enter kickstart image uri
uri0
Enter sup-1 to configure the 1st supsup-1
Enter sup-2 to configure the 2nd supsup-2
Command Modes • /exec/configure
B Commands51
B Commandsboot nxos (bootvar)
boot nxos (bootvar)boot nxos uri0|no boot nxos [uri0]
Syntax Description Negate a command or set its defaultsno
Configure boot variablesboot
Configure NXOS imagenxos
Type: uri
Enter NXOS image uri
uri0
Command Modes • /exec/configure
B Commands52
B Commandsboot nxos (bootvar)
bootmode boot[no] bootmode boot
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
boot in boot modeboot
Command Modes • /exec/configure
B Commands53
B Commandsbootmode boot
bootmode extruntime[no] bootmode extruntime
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
boot in runtimemode with extended diagsextruntime
Command Modes • /exec/configure
B Commands54
B Commandsbootmode extruntime
bootmode hitless[no] bootmode hitless
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
boot in hitless modehitless
Command Modes • /exec/configure
B Commands55
B Commandsbootmode hitless
bootmode module[no] bootmode module module {boot|extruntime|hitless|netboot|nodiagruntime|runtime}
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
set bootmode for a given module in the switchmodule
Type: integer
please enter module number
module
boot in boot modeboot
boot in runtime mode with extended diagsextruntime
boot in hitless modehitless
boot using boot netboot in runtime modenetboot
boot in runtimemode without running any diagsnodiagruntime
boot in runtime mode with normal diagsruntime
Command Modes • /exec/configure
B Commands56
B Commandsbootmode module
bootmode nodiagruntime[no] bootmode nodiagruntime
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
boot in runtimemode without running any diagsnodiagruntime
Command Modes • /exec/configure
B Commands57
B Commandsbootmode nodiagruntime
bootmode runtime[no] bootmode runtime
Syntax Description Negate a command or set its defaultsno
set bootmode for all modules in the switchbootmode
boot in runtime mode with normal diagsruntime
Command Modes • /exec/configure
B Commands58
B Commandsbootmode runtime
buffer-boost[no] buffer-boost
Syntax Description Negate a command or set its defaultsno
Enable extra buffers for this interfacebuffer-boost
Command Modes • /exec/configure/if-ethernet-all• /exec/configure/if-eth-non-member• /exec/configure/if-port-channel
B Commands59
B Commandsbuffer-boost
B Commands60
B Commandsbuffer-boost