Transcript
Page 1: Automatic Timer Instructions - Automatic Electric

Automatic Timer Instructions To enable an entry device or other accessory during specific hours

IMPORTANT: If none of the control board diagrams in this manual matchyour operator control board call GTO Technical Service at 800-543-1236 foradditional help.

Step 1:Connect the device to the gate operator according to theinstallation instructions for the device.

Step 2:Remove the wire from the device that is connected to theGREEN or COMMON terminal on the gate operator controlboard and connect it to the number 5 terminal on the timer.Take a piece of the same gauge wire and connect one endto the number 3 terminal of the timer and the other end tothe GREEN or COMMON terminal on the gate operatorcontrol board. See illustrations on next page.

Step 3:Connect a wire from the terminal 1 on the timer to thePOSITIVE ( + ) battery wire.

Step 4:Connect a second wire from terminal 2 on the timer to theNEGATIVE ( - ) battery wire.

Step 5:Set the timer to activate at the hour and minute you would like the device to becomeenabled.

Step 6:Set the timer to deactivate at the hour and minute you would like the device tobecome disabled.

The entry device will function only during the hours that the timer is activated.

2005, www.hooverfence.com

Page 2: Automatic Timer Instructions - Automatic Electric

WIRING DIAGRAMS

2005, www.hooverfence.com


Recommended