The GAIA series is a true on-line, double-conversion UPS designed in a rack or tower configuration and recommended for servers, VOIP, telecommunications and networking backup application. The GAIA series UPS has built in batteries to provide continuous and stable power to your critical loads when power events occur. With an extended battery cabinet, it can fulfill longer backup time requirements.
Applications
Model GA1000R / GES102R2000035
GA2000R/ GES202R2000035
GA3000R/ GES302R2000035
Power Rating - kVA/Watt 1KVA/800W 2KVA/1600W 3KVA/2100W
Input
Rating Voltage VAC 200/208/220/230/240, single phase
AC Voltage Range VAC160~275 (full load)
130~160 (linearly de-rating between 70% ~100% loading)DC Input Range VDC 24Vdc 48Vdc 72Vdc
Power Factor ≥ 0.97
Frequency Hz 50 or 60 ±5
Output
Voltage V 200/208/220/230(default)/240, single phase
Voltage Harmonic % ≤ 3 (Linear load); ≤6 (computer load)
Voltage regulation % ±2
Frequency Hz 50 or 60 ±0.05
Wave Form Pure Sine wave
Transient response <8%
Overload<105% : Continuous ; 105~125% : 3 minutes
125~150% : 30 seconds ; >150% : 0.5 second
Battery
Rating V 12V/8.5Ah; 2 pcs 12V/8.5Ah; 4 pcs 12V/8.5Ah; 8 pcs
Charging capability A 0.6 ~ 1.2 (default 0.8A) 0.74 ~ 1.38 (default 0.1A)
Typical Backup Time12 minutes (half load)4 minutes (full load)
13 minutes (half load)4 minutes (full load)
15 minutes (half load)5 minutes (full load)
Display LEDOnline, Bypass, On-battery, Overload, Battery low, Fault, Replace battery, Battery level,
Loading level
InterfaceStandard RS232 x 1, USB x 1, SNMP Slot x 1
Optional AccessoriesSNMP card, Modbus card, Relay I/O control card,
EnviroProbe, SNMP+5ports hub
OthersBattery Start Yes
Rail Kit Optional
Overall
Efficiency % > 87 (full load)
Dimension mm 440 x 335 x 89 440 x 432 x 89 440 x 610 x 89
Weight UPS kg 13 21 31
Weight Battery Cabinet kg 16 29 43
AdditionalGaia matching battery unit part number
GES022B109000 GES042B109000 GES062B109000
Amplon Gaia Series - With internal batteries
The R series is a true on-line, double-conversion UPS that comes in either a rack or tower configuration and is recommended for servers, VOIP, telecommunications and networking.The R series is designed for long backup time applications with the addition of a customized battery source. The built in high level charger shortens the recharging period and increases availability.
Amplon R Series Long Backup
Applications
Reliable power with intelligent energy-saving features The Amplon RT series delivers double-conversion on-line technology, high power density and input power factor, and low current harmonics with its advanced architecture. Designed in a rack or tower configuration with an LCD display, Amplon RT offers advanced performance for servers, data centers, networking, VoIP and telecommunications backup application.
The Amplon RT has 1+1 parallel redundancy function to provide higher reliability. Optional external battery pack can be added to fulfill longer backup time for mission critical applications.
Amplon RT Series Single phase
Applications
Model R-1K R-2K R-3K RT5K RT6K RT10K
UPS Part Number GES102R202035 GES202R202035 GES302R202035 RT5K RT5K RT5K
Power Rating - kVA/Watt 1KVA/700W 2KVA/1400W 3KVA/2100W 5kVA / 3.5kW 6kVA / 5.4kW 10kVA / 9kW
Input
Rating Voltage VAC 220/230/240, single phaseAC Voltage Range VAC 80~280 100~300 (full load)DC Input Range VDC 36Vdc 72Vdc 72Vdc 192 240Power Factor ≥ 0.99Frequency Hz 50 or 60 ±5
Output
Voltage V 200/208/220/230(default)/240, single phaseVoltage Harmonic % ≤ 3 (Linear load); ≤6 (computer load) ≤ 2 (linear load)Voltage regulation % ±2 ± 1 (static) ; ± 2 (typical)Frequency Hz 50 or 60 ±0.05
Wave Form Pure Sine wave
Overload<105% : Continuous ; 105~125% : 3 minutes
125~150% : 30 seconds ; >150% : 1 second
≤ 105% : Continuous ; 105~110% : 10 minutes ;
111~125% : 5 minutes ; 126~150% : 30 seconds ; >150% : Immediately
Charging capability A3 Amp
(adjustable, max. 4.5 Amp)
3.4 Amp(adjustable, max. 4 Amp)
3.4 Amp(adjustable, max. 4 Amp)
Built-in : max. 4 Amp (adjustable)
Optional Extra Charger
A 5 Amp (internal installation) 4 Amp (internal installation)
InterfaceStandard RS232 x 1, SNMP slot x 1
RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
Optional Accessories SNMP card, Modbus card, Relay I/O control card, EnviroProbe, SNMP+5 ports hub
OthersBattery Start Yes Yes
Optional / Accessories Rail Kit Included in packageRail kit ; Maintenance bypass box ;
Extended battery cabinet
Overall
Efficiency % > 87 (full load) 92 (normal ac-ac) / 96 (eco mode)
Dimension mm 440 x 450 x 89 440 x 670 x 89 440 x 628 x 131
Weight UPS kg 67 92 15.5 15.5 21.3
Server Te lecom Network VoIP Sto rage Med i ca l
The Ultron H series is an on-line three phase UPS which provides quality power for IT rooms, SMBs, telecommunications backup application, banking and industry. With dual mains input, it guarantees higher reliability for your mission critical applications. The Ultron H series has an built in manual bypass switch to keep power uninterrupted during maintenance. It is available in 3p-3p and 3p-1p models depending on your power needs.
Ultron H Series three phase series
Applications
The NH Plus series is Delta's next generation UPS featuring high efficieny, a hot swappable modular structure and N+X redundancy. With its industry leading 94% high efficiency, the NH Plus series delivers remarkable low total cost of ownership in terms of both capital expense and opeartion expense.
With N+X module and system redundancy to guarantee reliability and availability, the NH Plus series sets a new milestone for UPS protection and mission critical applications.
• Availablefrom20to480kVA (4unitsx120kVAinparallel)
• Redundancyatmoduleandsystem level.
• Hot-swappablefunctionensuresuninterrupted opearions during maintenance.
• Redundantauxiliarypowerandcontrol circuit ensures higher reliability.
• Built-inmaintenanceandstaticbypass switch.
• Modulardesignprovideseasymaintenance and scalability.
• Multi-languageLCDdisplay.
• Twosmartslotsandsixprogrammable dry contact outputs.
• Optionalextendedbatterycabinet for longer backup time.
• Highinputpowerfactor(pf>0.99) and low harmonic distortion (iTHD<3%).
• Savingsininstallationcosts.
• Energysavingswithmaximum94% high efficiency for lower operation costs.
• Compatiblewithgeneratorinstallation.
Applications
Availability Flexibility Lowest Total Cost of Ownership
Model NH+20 NH+40 NH+60 NH+80 NH+100 NH+120Chassis part number GES803HP3312035 GES124HP3312009
NHP 20KVA Power module part number 3915100486-SPower Rating - kVA 20 40 60 80 100 120Power Rating - kW 16 32 48 64 80 96
Input
Rating Voltage VAC 380/220, 400/230, 415/240 (3 Phase, 4-wire plus ground) AC Voltage Range VAC 208~477 / 120~276 (line-neutral)DC Input Range VDC 40 x 12Vdc (-240Vdc and +240Vdc)Input Current Harmonic Distortion % <3 (full load)Power Factor >0.99Frequency Hz 50 or 60 ±5Hz
Output
Voltage V 380/220, 400/230, 415/240 (3 Phase, 4-wire plus ground)Voltage Harmonic % < 3 (Linear load)Voltage regulation Static % ±1StaticFrequency Hz 50 or 60
Frequency RegulationHz ±0.05 (interior oscilator)Hz ±5 (Synchronized, adjustable in steps of 0.1Hz)
Overload Hz ≤ 125% : 10minutes ; ≤ 150% : 1minute
Overall
EffieciencyNormal % 94Eco % 97
Transfer Time ms 0Temperature °C 0~40
Dimension (WxDxH) mm 520(W) x 910(D) x 1165(H) 520(W) x 975(D) x
1695(H) Weight kg 170 200 230 260 320 350
Interface
StandardRS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2,
Parallel port x 1, Battery cabinet temperature x 4
Optional Accessories
SNMP card, Modbus card, Relay I/O control card, Environmental moni-toring box, SNMP+5 ports hub, Battery cabinet temperature sensor,
Battery cabinet temperature kit (For Delta cabinet), Battery cabinet status cable