Series ASC Anti Spin Control Valve

Technical Information

Page 2: Anti-spin Regulator Valve

2 DKMH.PN.380.A1.02 520L0525 07/2002

Series ASC Anti Spin Control ValveTechnical InformationOverview

© 2010, Sauer-Danfoss

Sauer-Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are properties of the respective companies. Sauer-Danfoss and the Sauer-Danfoss logotype are trademarks of the Sauer-Danfoss Group. All rights reserved.

Front page: F000 863, F003 013, F000 539, F003 018, F000 451, F003 019, F000 841, F000 867, P001 976

• Rugged design for mobile applications.

• Two “remaining flow” options available.

• Supply voltage 12 VDC

or 24 VDC

.

• Easy to service.

• Flexibility: 2 - 4 motors.

• Active while steering.

• Software optimization/adaption without hardware (orifice) changes.

• Individual setup per software:- Selection of different steering modes- Vehicle geometry - Track width - Wheel base - Wheel diameter - etc.

Description

Further System Components

Features

The Sauer-Danfoss Anti Spin Control valve (ASC-valve) is used e.g. in a propel drive line. The flow provided by a pump is split equally and ported to two propel motors, ensuring, both run at the same speed under all load, pressure, flow, and vehicle steering conditions. This prevents wheel slip and provides optimum vehicle traction. The ASC-valve concept allows therefore a wide variety of applications whenever equal flow share is demanded.

The ASC-valve in conjunction with a SUSMIC S1X microprocessor as well as steering and speed sensors combines the capabilities of modern digital electronics with the worldwide proven Sauer-Danfoss hydrostatic components, to enhance the machine performance and operation.

The microprocessor-based SUSMIC S1X provides software flexibility and is designed for the future. With easy-to change parameters (in software) it is possible to make an individual setup for different machine types.

• S1X-16 G2 AMP K196 S1X Electronic w/o CAN

• S1X-26 G2 AMP K196C S1X Electronic w CAN

Page 3: Anti-spin Regulator Valve

3520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationContents

Overview ..........................................................................................................................................2Description .....................................................................................................................................................................2Features ...........................................................................................................................................................................2Further System Components ...................................................................................................................................2

Sectional View..................................................................................................................................4Sectional View – ASC-valve .......................................................................................................................................4Circuit Diagram .............................................................................................................................................................4

System Schematic Diagram ............................................................................................................5Circuit Diagram – ASC-valve and System Components .................................................................................5

Technical Specifications ..................................................................................................................7General Specifications ................................................................................................................................................7Specific Data ..................................................................................................................................................................7Technical Data ...............................................................................................................................................................7Fluid Specifications ......................................................................................................................................................7

General Technical Specifications ....................................................................................................8Pressure Limits ..............................................................................................................................................................8Hydraulic Fluids.............................................................................................................................................................8Temperature and Viscosity .......................................................................................................................................9Fluid and Filtration .................................................................................................................................................... 10Independent Braking System ............................................................................................................................... 11Reservoir ....................................................................................................................................................................... 11

Functional Description ..................................................................................................................12General Description ................................................................................................................................................. 12ASC-valve Function ................................................................................................................................................... 12

Application Considerations ..........................................................................................................14Availability .....................................................................................................................................15

Available Options ...................................................................................................................................................... 15Technical Data ................................................................................................................................16Outline Dimensions .......................................................................................................................18

Page 4: Anti-spin Regulator Valve

4 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationSectional View

Sectional view – ASC-valve

Circuit Diagram

L

B

A

P

M8

M7

X3

P001 968

A M7 X3 M8 B

P L P001 969

Page 5: Anti-spin Regulator Valve

5520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationSystem Schematic Diagram

Circuit Diagram – ASC-valve and System Components

M

B P B

L

L2

L1

M2

M1

M4

M5

M3A

A

S

P001 970

M8

X3

M7

ASC-valve

Ports:A, B = Main pressure ports M4, M5 = Gage port - servo pressure S = Suction port - charge pump M7, M8 = Gage port - control pressure L, L1, L2 = Case drain X3 = Control pressure supply port M1, M2 = Gage port for A and B M3 = Gage port - charge pressure

Above schematics show the function of a hydrostatic transmission using a Series 90 Axial Piston Variable Displacement Pump with manual displacement control (MA) and two Fixed Displacement Hydraulic Motors with brakes and brake valve, controled by an ASC-valve.

Page 6: Anti-spin Regulator Valve

6 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationNotes

Page 7: Anti-spin Regulator Valve

7520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical Information

General Specifications

Fluid Specifications

Specific Data

Technical Data

Technical Specifications

Most specifications for the ASC-valve are listed below. For definitions of the various specifications, see the related pages in this publication.

epytevlaV evlav-CSAloops-owtlanoitroporpcirtcelE

noitisopnoitallatsnI yranoitercsiD

stnemeriuqermetsysrehtO riovreserelbatius,noitcetorperusserprevotiucriC

General Specifications

rebmunredrO 974705 238705 138705 338705 330815

egatloV V21CD

V42CD

V21CD

V42CD

V42CD

thgieW ]bl3.71[gk58.7

]nim/lagSU23[nim/l021 ]nim/lagSU61[nim/l06

noitisopdesolcniwolfgniniameR

]isp0085[rab004ta]nim/lagSU2.3[nim/l21 ]nim/lagSU5.0[nim/l2<

stropniardesaC 1 2

snoitcennocepipciluardyH.ssobgnir-OdaerhtthgiartsEAS+egnalfEAS:stroperusserpniaM

.ssobgnir-OdaerhtthgiartsEAS:tropgniniameR

snoitcennoccirtcelE V21,remiTroinuJPMACD

V42+CD

Specific Data

Maximum flow (at port P)

rab ]isp[

erusserpmumixaM 0.3 ]0.44[

Case Pressurerab ]isp[

erusserpmumixaM 084 ]0007[

System Pressure Range

rab ]isp[

ylppuslortnocmuminiM

)3X(erusserp02 ]092[

ylppuslortnocmumixaM

)3X(erusserp03 ]534[

Control Pressure

V21CD

V42CD

tnerrucybdnatS Am003 Am051

.xamderiuqeR

tnerrucAm0031-0021 Am056-006

Operating Current

C˚ ]F̊[

muminiM 04- ]04-[ tratsdloc,tnettimretni

detaR 401 ]022[

mumixaM 511 ]042[ tnettimretni)1 ,tnioptsettohehttA

.tropniardesacehtyllamron

Temperature Range1)

ssenilnaelcdiulfderiuqeRlevel

dednemmoceR βx

oitar-noitartlifnoitcusrof β

54-53(57= β

01≥�)2

dednemmoceR βx

oitar-erusserpegrahcrof

noitartlifβ

02-51(57= β

01≥� )01

telnidednemmoceRegrahcrofezisneercs

noitartliferusserp001 µ 521-m µm

Cleanliness Level and βx-Ratio

ISO 4406Class 22/18/13

mm 2 s/ ]SUS[

muminiM 7 ]94[ tnettimretni

dednemmoceRegnargnitarepo

08-21 ]073-07[

mumixaM 0061 ]0057[tnettimretni

tratsdloc

Viscosity

Page 8: Anti-spin Regulator Valve

8 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationGeneral Technical Specifications

Pressure Limits System pressure is the dominant operating variable affecting hydraulic unit life. High pressure, which results from high load, reduces expected life in a manner similar to the affects of high load on other mechanical assemblies such as engines and gear boxes.

Continuous pressure is the pressure at which the hydrostatic system could operate continuously and still achieve acceptable hydrostatic life. This pressure level varies depending on operating speed, and on the life requirements for a particular application. While most mobile applications require system pressure to vary widely during operation, a “weighted average” pressure can be derived from a machine duty cycle. (A duty cycle is a means of quantifying the pressure and speed demands of a particular system on a percent time basis). Once a duty cycle has been determined or estimated for a specific application, contact your Sauer-Danfoss representative for system life ratings for the application.

Maximum pressure is the highest intermittent pressure allowed, and is the relief valve setting. It is determined by the maximum machine load demand. For most systems, the load should move at this pressure.

Maximum pressure is assumed to occur a small percentage of operating time, usually less than 2 % of the total. Both the continuous and maximum pressure limits must be satisfied to achieve the expected life.

rab ]isp[

erusserpmumixaM 084 ]0007[

System Pressure Range

Hydraulic Fluids Ratings and data are based on operating with hydraulic fluids containing oxidation, rust and foam inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear, erosion and corrosion of the internal components.

Fire resistant fluids are also suitable at modified operating conditions. Please seeSauer-Danfoss literature Hydraulic Fluids and Lubricants Technical Information for more information.

It is not permissible to mix hydraulic fluids. For more information contact yourSauer-Danfoss representative.

The following hydraulic fluids are suitable:

• Hydraulic Oil ISO 11 158 - HM (Seal compatibility and vane pump wear resistance per DIN 51 524-2 must be met)• Hydraulic Oil ISO 11 158 - HV (Seal compatibility and vane pump wear resistance per DIN 51 524-3 must be met) • Hydraulic Oil DIN 51 524-2 - HLP• Hydraulic Oil DIN 51 524-3 - HVLP• Automatic Transmission Fluid ATF A Suffix A (GM)• Automatic Transmission Fluid Dexron II (GM), which meets Allison C-3 and Catapillar TO-2 test• Automatic transmission Fluid M2C33F and G (Ford)• Engine Oils API Classification CD, SE and SF• Super Tractor Oil Universal (STOU) special agricultural tractor fluid

Page 9: Anti-spin Regulator Valve

9520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationGeneral Technical Specifications

Temperature and Viscos-ity

Temperature and viscosity requirements must be concurrently satisfied. The data shown in the tables assume petroleum-based fluids are used.

The high temperature limits apply at the hottest point in the transmission, which is normally the case drain. The system should generally be run at or below the rated temperature. The maximum temperature is based on material properties and should never be exceeded.

Cold oil will generally not affect the durability of the transmission components, but it may affect the ability to flow oil and transmit power; therefore temperatures should remain 16 °C [30 °F] above the pour point of the hydraulic fluid. The minimum temperature relates to the physical properties of component materials.

For maximum unit efficiency the fluid viscosity should remain in the recommended operating range. The minimum viscosity should be encountered only during brief occasions of maximum ambient temperature and severe duty cycle operation. The maximum viscosity should be encountered only at cold start.

Heat exchangers should be sized to keep the fluid within these limits. Testing to verify that these temperature limits are not exceeded is recommended.

C˚ ]F̊[

muminiM 04- ]04-[ tratsdloc,tnettimretni

detaR 401 ]022[

mumixaM 511 ]042[ tnettimretni)1 ,tnioptsettohehttA

.tropniardesacehtyllamron

Temperature Range1)

mm 2 s/ ]SUS[

muminiM 7 ]94[ tnettimretni

dednemmoceRegnargnitarepo

08-21 ]073-07[

mumixaM 0061 ]0057[tnettimretni

tratsdloc

Viscosity

Page 10: Anti-spin Regulator Valve

10 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationGeneral Technical Specification

Fluid and Filtration To prevent premature wear, it is imperative that only clean fluid enter the hydrostatic transmission circuit. A filter capable of controlling the fluid cleanliness to ISO 4406 Class 22/18/13 or better under normal operating conditions is recommended.

The filter may be located either on the inlet (suction filtration) or discharge (charge pressure filtration) side of the charge pump. The selected filtration system must maintain a cleanliness level of 22/18/13 per ISO 4406.

The selection of a filter depends on a number of factors including the contaminant ingression rate, the generation of contaminants in the system, the required fluid cleanliness, and the desired maintenance interval. Filters are selected to meet the above requirements using rating parameters of efficiency and capacity.

Filter efficiency may be measured with a Beta ratio1) (βX). For simple suction-filtered

closed circuit transmissions and open circuit transmissions with return line filtration,a filter with a β-ratio within the range of β

35-45 = 75 (β

10 ≥ 2) or better has been found to

be satisfactory. For some open circuit systems, and closed circuits with cylinders being supplied from the same reservoir, a considerably higher filter efficiency is recommended. This also applies to systems with gears or clutches using a common reservoir. For these systems, a charge pressure or return filtration system with a filter β-rotation in the range of β

15-20 = 75 (β

10 ≥ 10) or better is typically required.

Since each system is unique, the filtration requirement for that system will be unique and must be determined by test in each case. It is essential that monitoring of prototypes and evaluation of components and performance throughout the test program be the final criteria for judging the adequacy of the filtration system. Please see Sauer-Danfoss literature Hydraulic Fluids and Lubricants Technical Information for more information.

1) Filter βx-ratio is a measure of filter efficiency defined by ISO 4572. It is defined as the ratio of the number

of particles greater than a given diameter (“x” in µm) upstream of the filter to the number of these particles downstream of the filter.

ssenilnaelcdiulfderiuqeRlevel

dednemmoceR βx

oitar-noitartlifnoitcusrof β

54-53(57= β

01≥�)2

dednemmoceR βx

oitar-erusserpegrahcrof

noitartlifβ

02-51(57= β

01≥� )01

telnidednemmoceRegrahcrofezisneercs

noitartliferusserp001 µ 521-m µm

Cleanliness Level and βx-Ratio

ISO 4406Class 22/18/13

Page 11: Anti-spin Regulator Valve

11520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical Information

IndependentBraking System Warning: The loss of hydrostatic drive line power in any mode of operation (e.g., forward,

reverse, or “neutral” mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic transmission must, therefore, be provided which is adequate to stop and hold the system should the condition develop.

Reservoir The function of the reservoir is to remove air and to provide make up fluid for volume changes associated with fluid expansion or contraction, possible cylinder flow, and minor leakage.

The reservoir should be designed to accommodate maximum volume changes during all system operating modes and to promote deaeration of the fluid as it passes through the tank.

A minimum reservoir volume equal to 1/2 to 1 1/2 times charge pump flow/min is suggested. This allows 30 seconds fluid dwell for removing entrained air at the maximum return flow. This is usually adequate to allow for a closed reservoir (no breather) in most applications. The reservoir outlet to the charge pump inlet should be above the bottom of the reservoir to take advantage of gravity separation and prevent large foreign particles from entering the charge inlet line.

The reservoir inlet (fluid return) should be positioned so that the flow to the reservoir is discharged below the normal fluid level, and also directed into the interior of the reservoir for maximum dwell and efficient deaeration.

General Technical Specification

Page 12: Anti-spin Regulator Valve

12 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical Information

General Description

ASC-Valve Function

Functional Description

The ASC-valve is used in anti slip systems for hydrostatic drive systems. It is possible to use this valve in wheeled machines with up to 4 wheels driven individually. The ASC System is especially useful for applications with fixed motors, but can also be combined with variable displacement motors.

The ASC System consists of a central digital controller SUSMIC S1X, speed sensors for each motor, the ASC-valve and steering sensors. It is important to note that in such system the amount of impulses per wheel rotation should show the highest possible frequency resolution in order to be able to ensure a good performance of the anti slip system.

The ASC-valve is of twin valve design and provides both motors with the required flow, generally these are the 2 motors for one axle not mechanical connected. The input flow in P is divided and equally ported to port A and B (see P001 968).

ASC-valve in neutral, no wheel slips

L

B

A

P

M8

M7

X3

P001 968

If for example the wheel connected to port “B” slips, the speed sensor detects this and sends a signal to the SUSMIC S1X controller. The SUSMIC S1X controller then will provide current to the electric proportional valve for port “B” and the spool in the ASC-valve closes the connection to port “B”, so a pressure drop across this connection is build up equal to the pressure of the other wheel connected to port “A” minus the pressure needed to drive wheel “B” (see P001 980). This limits the flow to wheel “B” and the wheel stops to slip and runs at the same speed as the wheel connected to port “A”

Page 13: Anti-spin Regulator Valve

13520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationFunctional Description

ASC-Valve Function(continued)

Wheel connected to port “B” slips, spool “B” 2/3 closed

L

B

A

P

M8

M7

X3

P001 980

If under extreme conditions and low speeds the wheel connected to port “B” continues to slip, spool “B” will close completely and only the “remaining flow” will flow toport “B” (see P001 995).

Wheel connected to port “B” at max slip, spool “B” completely closed.

L

B

A

P

M8

M7

X3

P001 995

Page 14: Anti-spin Regulator Valve

14 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical Information

The following measures must be considered for proper anti spin function:

• Remaining flow from the ASC-valve at maximum input current limits the minimum motor speed (possible remaining motor slip).

• Additional pressure limiter may be required if valve with low remaining flow at maximum input current is used and valve is arranged in the return line of the motor.

• When using more then one ASC-valve in an application either all valves must be placed in the supply line of all motors or all valves must be placed in the return line of all motors.

• Sum pressure for motors at downhill and deceleration condition must be considered.

• Integrated loop flushing is not allowed because of potential sum pressure condition (high pressure hydraulic fluid would be flushed out).

Application Considerations

Application Considerations

Page 15: Anti-spin Regulator Valve

15520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationAvailability

Typical ASC-valves with order numbers 507 479 (12 VDC

) or 507 832 (24 VDC

) with a remaining flow of 12 l/min [3.17 US gal/min] are used. These valves meet most application requirements. Please note, that due to the 12 l/min [3.17 US gal/min] remaining flow at 400 bar [5800 psi] the spinning wheel cannot be completely stoped.

If it is required that wheel slip is near zero at max closed position, the ASC-valves with a remaining flow of < 2 l/min [0.5 US gal/min] at 400 bar [5800 psi] are recommended. Order numbers for such valves are 507 831 (12 V

DC) or 507 833 (24 V

DC) for a maximum

flow of 60 l/min [16 US gal/min]. However, high sum pressure risk at downhill condition is higher.

In some cases it may be demanded, that the ASC-valve remains in max closed position, if voltage/current supply is lost. This is typically the case if the emergency stop button is hit. The ASC-valve with order number 518 033 (24 V

DC), 60 l/min [16 US gal/min] and

remaining flow of < 2 l/min [0.5 US gal/min] at 400 bar [5800 psi] provides a separat LX port.

Available Options

A M7 X3 M8 B

P LX L P001 979

In order to hold the ASC-valve in closed position this LX port may be closed by a solenoid valve which is closed when not activated. This maintains the pressure acting on the main spool and keeps it closed. Please note, that this causes the other spool to close as well. Carefully check the impact on the application.

Scematic ASC-valve 518 033

Page 16: Anti-spin Regulator Valve

16 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationTechnical Data

Technical Data Pressure drop

The pressure drop versus flow at normal condition (anti spin function not active) from P to A respectively from P to B and reverse is shown in below diagram at a viscosity of 28 mm2/s [70 SUS]. The flow entered in P is divided equally and ported to A and B.

Remaining flow at maximum closed position

Although the ASC-valve is in maximum closed position (anti spin function is activated and running at max slip condition) a remaining flow will allow the spinning wheel to slip. The remaining flow from P to A respectively from P to B is shown in below diagrams at a viscosity of 28 mm2/s [70 SUS].

Pressure drop versus flow

Remaining flow versus differential pressure for 507479 and 507832

Output/or input flow at port A or port B l/min [US gal/min]

Pres

sure

dro

p

bar

[psi

]

P001 971E

00

1.0

2.0

3.0

4.0

5.0

0

[14.5]

[29.0]

[43.5]

[58.0]

[72.5]

20[5.28]

40[10.57]

60[15.85]

80[21.13]

Differential pressure bar [psi]

Rem

ain

ing

flo

wl/

min

[US

gal

/min

]

0 50[725]

100[1450]

150[2175]

200[2900]

250[3625]

300[4350]

350[5075]

400[5800]

P001972E

00

[0.53]

[1.06]

[1.59]

[2.11]

[2.64]

[3.17]

[3.70] 14

12

10

8

6

4

2

000.02[0.005]

[0.011][0.016][0.021][0.026][0.032][0.040][0.042][0.048]

0.040.060.08

0.1

0.120.140.16

0.18

Differential pressure bar [psi]

0 50[725]

100[1450]

150[2175]

200[2900]

250[3625]

300[4350]

350[5075]

400[5800]

P001994E

Rem

ain

ing

flo

wl/

min

[US

gal

/min

]

Remaining flow versus differential pressure for 507831, 507833 and 518033

Page 17: Anti-spin Regulator Valve

17520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationTechnical Data

Technical Data(continued)

Spool stroke versus current

Due to tolerance stack up the spool may start to close (start to shut off one motor) already at 200 mA or may need 300 mA (24 V

DC option). To make sure the valve is securely

open when the anti spin function is not needed, the standby current has to be limited to300 mA for 12 V

DC and 150 mA for 24 V

DC.

These tolerances furthermore have an impact on the maximum spool closing position. The valve may need 650 mA for 24 V

DC respectively 1300 mA for 12 V

DC to be at maximum

closed position.

ASC-valve spool stroke versus current (all 12 VDC

options)

ASC-valve spool stroke versus current (all 24 VDC

options)

0 200 400Current mA

Stro

ke m

m [i

n]

600 800 1000 12000

2.00

4.00

6.00

8.00

10.00

12.00

14.00

0

[0.08]

[0.16]

[0.24]

[0.32]

[0.39]

[0.47]

[0.55]

P001 973E

min tolerance

max tolerancemid tolerance

0 100 200Current mA

Stro

ke m

m [i

n]

300 400 500 6000

2.00

4.00

6.00

8.00

10.00

12.00

14.00

0

[0.08]

[0.16]

[0.24]

[0.32]

[0.39]

[0.47]

[0.55]

P001 974E

min tolerance

max tolerancemid tolerance

Page 18: Anti-spin Regulator Valve

18 520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationOutline Dimensions

Outline Dimensions ASC-valves 507479, 507832, 507831, 507833

Iden

t-N

o.M

ade

in G

erm

any

89.0[3.50]

30.0

[1.1

8]

80.0

[3.1

5]12

5.0

[4.9

2]48

.0[1

.89]

45.5[1.79]

92.0

[3.6

2]

262.0[10.30]

P001 978E

57.2

[2.2

5]

18.5[0.73]

27.8[1.09]

Drain port LISO 11926-10.5625-18 UNF-2B[9/16-18 UNF-2B]

Control pressure supply X3ISO 11926-1

0.5625-18 UNF-2B[9/16-18 UNF-2B]

Gage port M7 control pressure for port AISO 11926-10.4375-20 UNF-2B[7/16-20 UNF-2B]

Gage port M8control pressure for port B

ISO 11926-10.4375-20 UNF-2B[7/16-20 UNF-2B]

M1018 [0.71] min.

full thread depth

Main port A ISO 11926-11.0625-12 UN-2B[1-1/16-12 UN-2B]

Main port B ISO 11926-11.0625-12 UN-2B[1-1/16-12 UN-2B]

45.0[1.77]

89.0[3.50]

96.8[3.81]

19.7[0.78]

73.5[2.89]

A

AB

B

A

M8

M7

P

L

M7

M7

M8

X3

Supply port PDN 25 Typ III 40 MPa seriesper ISO 6162 [SAE 1.00]4 Thread: 0.4375-14UNC-2B

[7/16-14UNC-2B]25 [1.00] min.full thread depth

X

X

mm[in]

AMP Junior Timer

A M7 X3 M8 B

P L

Contact your Sauer-Danfoss representative for specific installation drawings.

Page 19: Anti-spin Regulator Valve

19520L0525 • Rev BB • Dec 2010

Series ASC Anti Spin Control ValveTechnical InformationOutline Dimensions

Iden

t-N

o.M

ade

in G

erm

any

103.0[4.06]

90.0[3.54]

30.0

[1.1

8]

6.0

[0.2

4]80.0

[3.1

5]

125.

0[4

.92]

48.0

[1.8

9]

45.5[1.79]

92.0

[3.6

2]

262.0[10.30]

P001 975E

57.2

[2.2

5]

18.5[0.73]

27.8[1.09]

Drain port LXISO 11926-1

0.4375-20 UNF-2B[7/16-20 UNF-2B]

Drain port LISO 11926-10.5625-18 UNF-2B[9/16-18 UNF-2B]

Control pressure supply X3ISO 11926-1

0.5625-18 UNF-2B[9/16-18 UNF-2B]

Gage port M7 control pressure for port AISO 11926-10.4375-20 UNF-2B[7/16-20 UNF-2B]

Gage port M8control pressure for port B

ISO 11926-10.4375-20 UNF-2B[7/16-20 UNF-2B]

M1018 [0.71] min.

full thread depth

Main port A ISO 11926-11.0625-12 UN-2B[1-1/16-12 UN-2B]

Main port B ISO 11926-11.0625-12 UN-2B[1-1/16-12 UN-2B]

45.0[1.77]

89.0[3.50]

96.8[3.81]

19.7[0.78]

73.5[2.89]

A

AB

B

A

M8

M7LX

P

L

M7

M7

M8

X3

LX

LX

Supply port PDN 25 Typ III 40 MPa seriesper ISO 6162 [SAE 1.00]4 Thread: 0.4375-14UNC-2B

[7/16-14UNC-2B]25 [1.00] min.full thread depth

X

X

mm[in]

AMP Junior Timer

A M7 X3 M8 B

P LX L

Outline Dimensions(continued)

ASC-valve 518033 with 2 case drain ports

Contact your Sauer-Danfoss representative for specific installation drawings.

Page 20: Anti-spin Regulator Valve

Local address:

Sauer-Danfoss GmbH & Co. OHGPostfach 2460, D-24531 NeumünsterKrokamp 35, D-24539 Neumünster, GermanyPhone: +49 4321 871 0Fax: +49 4321 871 122

Sauer-Danfoss ApSDK-6430 Nordborg, DenmarkPhone: +45 7488 4444Fax: +45 7488 4400

Sauer-Danfoss is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile o� -highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of o� -highway vehicles.

We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Sauer-Danfoss – Your Strongest Partner in Mobile Hydraulics.

Go to www.sauer-danfoss.com for further product information.

Wherever o� -highway vehicles are at work, so is Sauer-Danfoss.

We o� er expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.

Please contact the Sauer-Danfoss representative nearest you.

Products we off er:

• Bent Axis Motors

• Closed Circuit Axial Piston Pumps and Motors

• Displays

• Electrohydraulic Power Steering

• Electrohydraulics

• Hydraulic Power Steering

• Integrated Systems

• Joysticks and Control Handles

• Microcontrollers and Software

• Open Circuit Axial Piston Pumps

• Orbital Motors

• PLUS+1™ GUIDE

• Proportional Valves

• Sensors

• Steering

• Transit Mixer Drives

Members of the Sauer-Danfoss Group:

Comatrolwww.comatrol.com

Schwarzmüller-Inverterwww.schwarzmueller-inverter.com

Turolla www.turollaocg.com

Hydro-Gear www.hydro-gear.com

Sauer-Danfoss-Daikinwww.sauer-danfoss-daikin.com

Sauer-Danfoss (US) Company2800 East 13th StreetAmes, IA 50010, USAPhone: +1 515 239 6000Fax: +1 515 239 6618

Sauer-Danfoss-Daikin LTD.Shin-Osaka TERASAKI 3rd Bldg. 6F1-5-28 Nishimiyahara, Yodogawa-kuOsaka 532-0004, JapanPhone: +81 6 6395 6066Fax: +81 6 6395 8585

w w w . s a u e r - d a n f o s s . c o m520L0525 • Rev BB • Dec 2010


Recommended