8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
1/88
Users Manual
Manuale dinstruzioni
Wall Mounted Room Air ConditionersK Condizionatore split
Model names//ModelloGAN/GAG-A28IVLGAN/GAG-A35IVLGAN/GAG-A53IVLGAN/GAG-A70IVL
For the proper use of this product, kindly read carefully this manual and keep it forfuture reference.
, .
Per un corretto funzionamento, leggere attentamente questo manuale primausare il condizionatore e conservarlo per una futura consultazione.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
2/88
2 GB
CONTENTS
Operation and MaintenanceSafety Precautions _____________________________________________________ 3-5Name of Parts ___________________________________________________________ 6Operation of Remote controller__________________________________________ 7-12Emergency Operation ___________________________________________________ 13Care and Cleaning ___________________________________________________ 14-15Troubleshooting _____________________________________________________ 16-18Operation Tips ______________________________________________________ 19-20
Installation ServiceNotices for Installation ________________________________________________ 21-23
Installation Drawing _____________________________________________________ 24Installation of Indoor Unit _____________________________________________ 25-27Installation of Outdoor Unit ____________________________________________ 28-29Check after Installation and Operation Test __________________________________ 30
Never attempt.
The physical product may differ from the drawing in this manual for different display.If there are some differences between them, please refer to the physical product as thestandard.
This appliance is not intended for use by persons (including children) with reducedphysical, sensory or mental capabilities or lack of experience and knowledge, unlessthey have been given supervision or instruction concerning use of the appliance by aperson responsible for their safety.Children should be supervised to ensure they are away from the appliance.
Do not dispose this product as unsorted municipal waste.Collection of such waste separately for special treatment is necessary.
Be sure to follow this instruction
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
3/88
3 GB
Safety Precautions
Please read the following notices before operation
WARNING
If theres abnormal pheno-menon (like smell of burning),please cut off the power im-mediately and then contactwith authorized maintenancecenter.
The special circuit must beadopted for power supply toavoid re.
Before cleaning the air condi-tioner, please cut off the power. Power supply should adopt thespecial circuit with the protec-tion of air switch and the capac-ity must be suffi cient.Pease do not turn on or turn offthe air conditioner frequently.
Y-type connection is adoptedfor the power supply of this airconditioner.If the power cord isdamaged, it must be replaced
by the manufacture, mainte-nance center or a similarly qual-ied person to avoid a hazard.
When the voltage is too high,electric elements can be dam-aged easily; if the voltage toolow, the compressor will vibrateercely, which may damage thecooling system or compressorand electric components cantoperate.
Otherwise, it will cause electric
shock or injury.
cut off power
Do not use octopus multipur-
pose socket or mobile wiring
board for wire connection.
Please cut off the power supplywhen the air conditioner wontbe used for an extended periodof time.
Do not damage the power cordor use unspecied power cord.
Otherwise, it may cause re due
to overheating of power cord.
Otherwise, it will accumulate
dust and it may cause overheat-
ing, re and other accidents.
Do not operate the air condi-tioner with wet hands.
Do not cut off or damage thepower cord or signal controlwire. If the power cord or signalcontrol wire of air conditioneris damaged,please replace it bythe professional with speciedpower cord.
Otherwise, it may cause electric
shock.
If this abnormal status is kept on,
air conditioner may be damaged
or even cause electric shock or
re.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
4/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
5/88
5 GB
Safety Precautions
Do not cut off or damage the power cords orcontrol cords. If they are damaged, pleasecontact the dealer or qualied service per-sonnel.
Do not insert your hands or objects into
the air in let or outlet.
Do not expose yourself to cold air directlyfor a long time.
Do not splash water on the air conditioner. Do not place a burner near the air conditioner.
Do not use the unit for any other purpose,such as preserving food or drying clothes.
Do not expose animals or plants directly to
the air ow.
It may cause an accident.
Its not good for your health.
It may cause electric shock or malfunction.
It will cause CO toxi-
cosis due to incom-
plete burning.
It may have a detrimental effect on them.
To change the airow direction, adjust thevertical and horizontal air ow direction byusing the remote controller.
Vertical Louver Horizontal Louver
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
6/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
7/88
7 GB
Operation of Remote Controller
ON/OFFPress it to start or stop operation.
SWINGPress it set swing angle.
TIMER ONPress it to set auto-on timer.
-Press it to decrease temperature setting.
I FEEL(Page 10)
CLOCKPress it set clock.
+Press it to increase temperature setting.
Press it to set HE ALTH or AIR function.
TIMER OFFPress it to set auto-off timer.
MODEPress it to select operation mode(AUTO/COOL/DRY/FAN/HEAT).
SLEEP(Page 11)
TURBO(Page 11)
FANPress it to set fan speed.
TEMP(Page 11)
LIGHT
Press it to turn on/off the light.
X-FAN(Page 11)
1
6
11
2
7
12
3
8
13
4
9
14
5
10
15
16
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
8/88
8 GB
Operation of Remote Controller
17
22
23
25
24
18 19 20 21
MODE iconIf MODE button is pressed,current operation mode icon
AUTO, COOL,DRY, FAN or HEAT
only for heat pumpmodels) will show.
Up & down swing iconis displayed when pressing
the up & down swing down button.Press this button again to clear thedisplay.
LOCK icon is displayed by pressing +and - buttons simultaneously. Pressthem again to clear the display.
SET TIME displayAfter pressing TIMER button,ON orOFF will blink.This area will showthe set time.
DIGITAL displayThis area will show the set temperature.In SAVE mode,SE will be displayed.
AIR iconis displayed when pressing the
AIR button. Press this button again
to clear the display.Note: This function is not applicableto partial of models.This function is not available for this model.
LIGHT iconis displayed by pressing the
LIGHT button. Press LIGHT buttonagain to clear the display.
TEMP icon:Pressing TEMP button,
(set temperature),
(indoor ambient temperature)
(outdoor ambient temperature)
and blank is displayed circularly.
NOTE: function is applicable to
partial of models.
This function is not available for this model
SLEEP icon
is displayed by pressingthe SLEEP button. Press thisbutton again to clear the display.
17 21
22
23
24
25
19
20
18
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
9/88
9 GB
Operation of Remote Controller
HEALTH iconis displayed when pressing the
HEALTH button. Press this buttonagain to clear the display.
FAN SPEED displayPress FAN button to select thedesired fan speed setting(AUTOLow-Med-High).Your selection willbe displayed in the LCD windows,except the AUTO fan speed.
I FEEL iconis displayed when pressing
the I FEEL button. Press thisbutton again to clear the display.
8C Heating icon:is displayed when Pressing
TEMP and CLOCK simultaneouslyin Heat mode
NOTE: This function is applicable topartial of models.
This function is not availablefor this model
X-FAN iconis displayed when pressing the
X-FAN button. Press this buttonagain to clear the display.
TURBO iconis displayed when pressing the
TU RBO button. Press this button
again to clear the display.
26 29
30
31
27
28
2930
262731
28
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
10/88
10 GB
Operation of Remote Controller
Remote Controller Description
ON/OFF:
Press this button to turn on the unit . Press this button again to turn off the unit.
Press this button to decrease set temperature. Holding it down above 2 seconds rapidly de-creases set temperature. In AUTO mode, set temperature is not adjustable.
+Press this button to increase set temperature. Holding it down above 2 seconds rapidly in-creases set temperature. In AUTO mode, set temperature is not adjustable.
MODEEach time you press this button, a mode is selected in a sequence that goes from AUTO, COOL,
DRY, FAN, and HEAT *, as the following:
*Note: Only for models with heating function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will notbe displayed on the LCD, and the unit will automatically select the suitable operationmode in accordance with the room temperature to make indoor room comfortable.
FANThis button is used for setting Fan Speed in the sequence that goes from AUTO,
, to then back to Auto.
Auto
Low speed Medium speed High speed
SWINGPress this button to set up & down swing angle, which circularly changes as below:
OFF
This remote controller is universal. If any command , or is sent out,the unit will carry out the command as
indicates the guide louver swings as:
I FEEL:Press this button to turn on I FEEL function. The unit automatically adjust temperatureaccording to the sensed temperature. Press this button again to cancel I FEEL function.
/
Press this button to achieve the on and off of healthy and scavenging functions inoperation status. Press this button for the rst time to start scavenging function;LCD displays . Press the button for the second time to start healthy and scavenging
functions simultaneously; LCD displays and . Press this button for the thirdtime to quit healthy and scavenging functions simultaneously.Press the button for thefourth time to start healthy function; LCD display . Press this button again to repeatthe operation above.
1
2
3
4
5
6
7
8
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
11/88
11 GB
Operation of Remote Controller
SLEEP:
Press this button to go into the SLEEP operation mode. Press it again to cancel this function.This function is available in COOL , HEAT (Only for models with heating function) to maintainthe most comfortable temperature for you.
TEMP:Press this button, you can see indoor set temperature, indoor ambient temperatureon indoor units display. The setting on remote controller is selected circularly as below:
When selecting with remote controller or no display, temperature indicator on indoor
unit displays set temperature; When selecting with remote controller, temperature indica-tor on indoor unit displays indoor ambient temperature; 3s later or within 3s it receives otherremote control signal that will return to display the setting temperature.Caution:This model hasnt outdoor ambient temperature display function. While remote controller canoperate and indoor unit displays set temperature.Its defaulted to display set temperature when turning on the unit. Only for the models with temperature indicator on indoor unit.
TIMER ON :Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simplypress this button again.After press of this button, disappears and ON blinks. 00:00 is displayed for ON time set-ting. Within 5 seconds, press + or - button to adjust the time value. Every press of either buttonchanges the time setting by 1 minute. Holding down either button rapidly changes the timesetting by 1 minute and then 10 minutes. Within 5 Seconds after setting, press TIMER ON but-ton to conrm.
CLOCK :Press CLOCK button, blinking. Within 5 seconds, pressing + or - button adjusts the presenttime. Holding down either button above 2 seconds increases or decreases the time by 1 min-ute every 0.5 second and then by 10 minutes every 0.5 second. During blinking after setting,press CLOCK button again to conrm the setting, and then will be constantly displayed.
TIMER OFF :Press this button to initiate the auto-off timer. To cancel the auto-timer program, simply pressthe button again.TIMER OFF setting is the same as TIMER ON.
TURBO:Press this button to activate / deactivate the Turbo function which enables the unit to reachthe preset temperature in the shortest time. In COOL mode, the unit will blow strong coolingair at super high fan speed. In HEAT mode, the unit will blow strong heating air at super highfan speed.
LIGHT:Press LIGHT button to turn on the displays light and press this button again to turn off the
display s light. If the light is turned on, is displayed. If the light is turned off, disappears.
9
10
11
12
13
14
15
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
12/88
12 GB
Operation of Remote Controller
X-FAN:Pressing X-FAN button in COOL or DRY mode,the icon is displayed and the indoor fan willcontinue operation for 2 minutes in order to dry the indoor unit even though you have turned
off the unit.After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO,FAN or HEAT mode.
Combination of + and - buttons: About lockPress + and - buttons simultaneously to lock or unlock the keypad. If the remote controlleris locked, is displayed. In this case, pressing any button, blinks three times.
Combination of MODE and - buttons : About switch between Fahrenheit and centigradeAt unit OFF, press MODE and - buttons simultaneously to switch betweenand.
Combination of TEMP and CLOCK buttons: About Energy-saving Function
Press TEMP and CLOCK simultaneously in COOL mode to start energy-saving function.Nixie tube on the remote controller displays SE. Repeat the operation to quit the function.
Combination of TEMP and CLOCK buttons : About 8Heating FunctionPress TEMP and CLOCK simultaneously in HEAT mode to start 8Heating Function. Nixietube on the remote controller displays and a selected temperature of 8. (46if Fahren-heit is adopted). Repeat the operation to quit the function.
About Back-lighting FunctionThe unit lights for 4s when energizing for the rst time, and 3s for later press.
Replacement of Batteries
1. Remove the battery cover plate from the rear of the remote controller. (As shown in the gure)2.Take out the old batteries.3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity.4. Reinstall the battery cover plate.
Notes:
When replacing the batteries, do not use old or differenttypes of batteries, otherwise, it may cause malfunction. If the remote controller will not be used for a long time,
please remove batteries to prevent batteries from leaking. The operation should be performed in its receiving range. It should be kept 1m away from the TV set or stereo sound
sets. If the remote controller does not operate normally, please
take the batteries out and reinsert them after 30 seconds.If itstill cant operate properly, replace the batteries.
17
16
18
19
20
21
Sketch map forreplacing batteries
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
13/88
13 GB
Emergency Operation
Emergency Operation
When the remote controller is lost
or damaged, please use the manual switchon the main unit. In that case, the unit willoperate in AUTO mode and the temperaturesetting or fan speed can not be changed.The manual switch can be operated as below:
Turn on the unit: Press AUTO/STOP button to enterAUTO mode.
The microcomputer will select the mode (COOL, HEAT,FAN) automatically according to the room temperature
for reaching comfortable effect.
Turn off the unit: Press the AUTO/STOP button toswitch off the unit.
The operation mode is seen in the following table.
Mode Model Temperature setting Airow rate
AUTO COOLING 25(COOL, FAN) AUTO
AUTO HEAT PUMP 25(COOL, FAN) AUTO
AUTO HEAT PUMP 20(HEAT) AUTO
This switch is to be applied when the remote controlleris missing.
Manual switch
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
14/88
14 GB
Care and Cleaning
Caution
Disconnect the power supply before cleaning and maintenance.
Do not splash water on the units for cleaning, as electric shocks may occur.
Wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleaner (not withvolatile liquid such as thinner or gasoline).
Cleaning the Front Panel
Remove the front panel. Dip a piece of cloth into the water colder than 45and dry it . Thenwipe the dirty part of front panel.Note: Do not immerse the front panel into water so as to protect microcomputer componentsand circuit diagram on the front panel.
Cleaning the Air Filter (every 3 months)
Note: Do not to touch the n of indoor unit during cleaning to avoid personal injury.
1. Take down the air lter
Lift up the front panel.Pull the air lter downwards to take it off,as shown in Fig.(a,b).
2. Clean the air lterUse a vacuum cleaner to remove dust.If the lter are dirty, wash them with warm waterand a mild detergent.Dry the lters in the shade.
Note: Never use water above 45to clean the airlter or it can cause deformation or discoloration.
3. Reinstall the air lterReinstall the air lter Reinstall the lters alongthe direction of arrowhead.Close the panel.
(Fig.a)
(Fig.b)
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
15/88
15 GB
Care and Cleaning
Check before Use1. Be sure that nothing obstructs the air outlet and inlet.
2. Check if the batteries of remote controller are replaced.
3. Check if the installation stand of the outdoor unit is damaged. If damaged, consult the technicians.
Maintenance after Use
1. Switch off the power supply.
2. Clean the lter and bodies of indoor and outdoor units.
3. Clear obstructions from the outdoor unit.
4. Repaint the rubiginous place on the outdoor unit to prevent it from spreading.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
16/88
16 GB
Troubleshooting
CautionThe air conditioner is not user serviceable. Incorrect repair may cause electric shock or re so
please contact an authorized service center for professional repair Following checks prior to con-tact may save your time and money.
The unit does not operate
Odours are emitted
Water owing noise
Mist is emitted in COOL mode
Cracking noise
The unit does not operate if it is turned on im-mediately after it is turned off. This is to protectthe unit. You should wait about 3 minutes.
Some odours may be emitted from the indoorunit. This is the result of room smells (such asfurniture, tobacco, ect.) which have been tak-en into the air conditioner.
Consult authorized service center for cleaningif the odours still exist.
The swishing noise like water owing is therefrigerant owing inside the unit.
During cooling operation, a thin mist may be
seen emitted from the indoor unit due to highroom temperature and humidity.
After a period of time, the mist will disappearwith the decrease of room temperature andhumidity.
This is the sound of friction caused by expan-sion and/or contraction of panel or other partsdue to the change of temperature.
Phenomenon Troubleshooting
Waiting
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
17/88
17 GB
Troubleshooting
The unit can not be started up
Cooling/Heating effect is poor
Remote controller is not available
Water leakage of indoor unit
Water leakage of outdoor unit
Noise from indoor unit
Is the power cut off?
Is the power plug loose? ( if applicable ) Is the circuit protection device tripped off?
Is voltage higher or lower? (Tested by professionals)
Is the TIMER correctly used?
Is temperature setting appropriate?
Is the inlet or outlet blocked?
Is the lter dirty?
Is the window or the door open?
Is low fan speed set?
Are there heat sources in the room?
Check if there is magnetic or electrical interfer-
ence near the unit that may affecting opera-
tion of the controller. In this case, pull the plug
out and reinsert it.
Is the remote controller within its operating
range or obstructed? Check the condition of
the batteries and replace them if necessary.
Check if the remote controller is damaged.
The humidity is high.
Condensing water overows.
Drain hose is loose.
During cooling operation, water condensateis generated around the pipes and connection
joints. During defrosting operation,the thaw water
ows out. During heating operation,the water on the heat
exchanger drips out.
The noise emitted when the fan or compressor
relay is switching on or off. When the defrosting operation is started or
stopped, there is a sound of refrigerant owingin the reverse direction.
Phenomenon Troubleshooting
Breaking off
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
18/88
18 GB
Troubleshooting
Phenomenon Troubleshooting
Indoor unit can not blow air:
Moisture on air outlet :
C5:Malfunction of connector jumper:
F1: Malfunction of indoor ambient temperaturesensor
F2: Malfunction of evaporator temperaturesensor
There is harsh sound during operation.
Strong odours are emitted during operation.
Water is leaking from the unit.
The air switch or protection switch often trips. Water or other liquid is splashed into the unit.
Power cord and power plug is overheating.
Stop operation
and cut off the power supply.
Defrosting or oil teturn mode
H6: Indoor fan block
If any one of the following situations occurs, immediately stop all operations,cut off the power supply, and contact the authorized personnel
In HEAT mode, when the temperature of in-
door heat exchanger is very low, air ow isstopped in order to prevent cold air. (Within2minutes)
In HEAT mode, when the outdoor temperatureis low or humidity is high, frost will be formedon the outdoor heat exchanger. The unit willdefrost automatically and indoor unit will stopblowing air for 3-12minutes.
During defrosting operation, water or vapourmay be emitted.
In DRY mode, the indoor fan will stop blowingair for 3-12 minutes in order to avoid condens-
ing water being vaporised again.
If the unit operates at high humidity for a longtime, moisture will be generated on the airoutlet grill and then drip off.
Check if the connector jumper contacts prop-erly. If the PCB is to be replaced, please take offthe old for the new PCB.
Check if indoor room temperature sensor isconnected properly.
Check if the evaporator temperature is con-nected properly.
It is normal. The indicating lamp in heat mode will wink
0.5s and light 10s.
Check if the terminal of the indoor motor isconnected properly.
Replace the fan motro or the inddor board ifdisabled.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
19/88
19 GB
Operation Tips
Cooling Operation
Principle:Air conditioners absorb heat in the room and transmit it to the outdoor unit, so that the roomtemperature is decreased. The cooling capacity will increase or decrease according to outdoorambient temperature.Antifreezing Function:If the unit is operating in COOL mode and in low ambient temperature, frost may be formed onthe heat exchanger. When indoor heat exchanger temperature decreases below zero, compres-sor will stop operation to protect the unit.
Heating OperationPrinciple:Air conditioners absorb heat from outdoors and transmit it to the indoor unit, increasing roomtemperature. The heating capacity will decrease at low ambient temperature.
Defrosting:When outdoor temperature is low but humidity is high, frost may form on the outdoor unit dur-ing extended operation, affecting heating effi ciency. The air conditioner may stop operationduring auto defrosting operation.During auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During defrosting, the indoor indicator ashes and the outdoor unit may emit vapor.This is not malfunction.After defrosting is nished, the heating operation will recover automatically.
Anti-cold Air Function:In HEAT mode, the indoor fan will not operate in order to prevent cold air blowing out(within 2 minutes) if indoor heat exchanger doesnt reach a certain temperature under thefollowing three states:
1. Heating operation starts; 2. After Auto Defrosting is nished; 3.Heating at low temperature.
Rest Heat BlowIn the following situations, the indoor unit may still run for some time,to blow out the rest heat of the indoor unit.1. In HEAT mode, the temperature reaches the setting value, the compressor stops and the in-
door fan still run for 60s.2. In HEAT mode, if you turn off the unit, the compressor stops and the indoor fan still run for 10s.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
20/88
20 GB
Operation Tips
Operating Temperature Range
Indoor side DB/WB(oC) Outdoor side DB/WB(oC)
Maximum cooling 32/23 43/
Maximum heating 27/--- 24/18
The operating temperature range (outdoor temperature) for cooling only unit is 10~ 43for heat pump unit is -15~48.
Tips for energy saving:
* Do not overcool or overheat. Setting temperature at a moderate level helps energy saving.
* Cover windows with a blind or a curtain. Blocking sunlight and air from outdoors is favorable for cooling (heating).
* Clean air lters once per two weeks.
Clogged air lters lead to ineffi cient operation and energy waste.
Tip for relative humidity:
Condensate water is likely to form at the air outlet if cooling or drying for a long time when therelative humidity is more than 80% ( with doors and windows open).
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
21/88
21 GB
Notices for Installation
Caution
1. The unit must only be installed by authorized service center according to local or governmentregulations and in compliance with this manual .
2. Before installation, please contact with local authorized maintenance center. If the unit is notinstalled by the authorized service center, the malfunction may not be solved due to discom-modious contacts.
3. When removing the unit to the other place, please rstly contact with the local authorizedservice center.
4. Warning: Before obtaining access to terminals, all supply circuits must be disconnected.5. For appliances with type Y attachment, the instructions shall contain the substance of the
following. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualied persons in order to avoid a hazard.6. The appliance must be positioned so that the plug is accessible.7. The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.8. The instructions shall state the substance of the following: This appliance is not intended for use by persons(including children)with reduced physical,
sensory or mental capabilities,or lack of experience and knowledge,unless they have beengiven supervision or instruction concerning use of the appliance by a person responsible fortheir safety.
Children should be supervised to ensure that they do not play with the appliance.
Installation Site Instructions
Proper installation site is vital for correct and effi cient operation of the unit. Avoid thefollowing sites where:
strong heat sources, vapours, ammable gas or volatile liquids are emitted.
high-frequency electro-magnetic waves are generated by radio equipment, welders and medi-
cal equipment.
salt-laden air prevails (such as close to coastal areas).
the air is contaminated with industrial vapours and oils.
the air contains sulphures gas such as in hot spring zones.
corrosion or poor air quality exists.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
22/88
22 GB
Notices for Installation
Installation Site of Indoor Unit
1. The air inlet and outlet should be away from the obstructions. Ensure the air can be blown
through the whole room.2. Select a site where the condensing water can be easily drained out, and where it is easily con-nected for outdoor unit.
3. Select a place where it is out of reach of children.
4. Select the place where the wall is strong enough to withstand the full weight and vibration ofthe unit.
5. Be sure to leave enough space to allow access for routine maintenance. The installation siteshould be 250cm or more above the oor.
6. Select a place about 1m or more away from TV set or any other electric appliance.
7. Select a place where the lter can be easily taken out.
8. Make sure that the indoor unit is installed in accordance with installation dimension instructions.
9. Do not use the unit in the laundry or by swimming pool etc.
Installation Site of Outdoor Unit
1. Select a site where noise and outow air emitted by unit will not annoy neighbors.
2. Select a site where there is suffi cient ventilation.
3. Select a site where there is no obstruction blocking the inlet and outlet.
4. The site should be able to withstand the full weight and vibration.
5. Select a dry place, but do not expose the unit to direct sunlight or strong wind.
6. Make sure that the outdoor unit is installed in accordance with the installation instructions, and isconvenient for maintenance and repair.
7. The height difference between indoor and outdoor units is within 5 m, and the length of the connect-ing tubing does not exceed 10 m.
8. Select a place where it is out of reach of children.
9. Select a place which will not block pedestrian passage and inuence the city appearance.
Safety Precautions for Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety regula-
tions.2. Dont drag the power cord emphatically.
3. The unit should be reliably earthed and connected to the special earth device by the professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent shortcircuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6. The appliance shall be installed in accordance with national wiring regulations.
7. An all-pole disconnection switch with a contact separation of at least 3mm in all poles should beconnected in xed wiring. For models with a power plug, make sure the plug is within reach afterinstallation.
8. Including an air switch with suitable capacity, please note the following table. Air switch shouldbe included magnet buckle and heating buckle function, it can protect the circuitshort and over-load. (Caution: please do not use the fuse only for protect the circuit)
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
23/88
23 GB
Notices for Installation
Air-conditioner (W ) Air switch capacity
18K, 24K 25A
Note:
Make sure the live wire, neutral wire and earth wire in the family power socket are properly con-nected. There should be reliable circuit in the diagram.
Inadequate or incorrect electrical connections may cause electric shock or re.
Earthing Requirements
1. Air conditioner is type I electric appliance. Please ensure the unit is reliably earthed.
2. The yellow-green wire in air conditioner is the earthing wire which can not be used for otherpurposes. Improper earthing may cause electric shock.
3. The earth resistance should accord to the national criterion.
4. The users power must have reliable earthing terminal. Please dont connect the earthing wirewith the following:
Water pipe
Gas pipe
Contamination pipe
Other place that professional personnel consider is unreliable
5. The model and rating values for fuses accord with the silk print on fuse cover or related PCB.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
24/88
24 GB
Installation Drawing
Space to the ceiling
Space to the wall
Space to the oorAir outlet side
The dimensions of the space necessary for properinstallation of the unit include the minimum
permissible distances to adjacent parts.
Space to the wall
15cmabove
300cmabove
250cm
above
50cmab
ove
30cm
abov
e
50cm above
30cm above
200cm
abo
ve
Space to theobstruction
Air inlet side
Space to the wall
Space to the wall
Air outlet side
15cm above15cm above
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
25/88
25 GB
Installation of Indoor Unit
Installation of Mounting Plate
1. Mounting plate should be installed horizontally. As the water trays outlet for the indoor unit istwo-way type, during installation, the indoor unit should slightly slant to water trays outlet forsmooth drainage of condenser water.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been xed rmly enough to withstand about 60 kg. Mean-while, the weight should be evenly shared by every screw.
Drill Piping Hole
1. Slant the piping hole ( 55/ 70) on the wallslightly downward to the outdoor side.
2. Insert the piping-hole sleeve into thehole to prevent the connection pipingand wiring from being damaged whenpassing through the hole.
Above 150from the wall
Above 150from the wall
Above 150from the wall
Above 150from the wall
Above 150 from theceiling
Above 150 from the ceiling
Above 150 from the ceiling
Above 150from the wall
GAN/GAG -A28IVLGAN/GAG -A35IVL
GAN/GAG -A53IVL
GAN/GAG -A70IVL
IndoorWall pipe
outlet pipe ofindoor unit
outlet pipe ofindoor unit
rubber belt
rubber belt
rubber beltoutlet pipe of
indoor unit
insulatingtube
Seal pad
Outdoor
Installation of Drain Hose
1. Connect the drain hose to the outlet pipe of the in-
door unit. Bind the joint with rubber belt.
2. Put the drain hose into insulating tube.
3. Wrap the insulating tube with wide rubber belt toprevent the shift of insulating tube. Slant the drainhose downward slightly for smooth drainage ofcondensing water.
outlet pipe ofindoor unit
drain hose
drain hose
connected insulatingtube
Fig.5
GAN/GAG -A28IVL
GAN/GAG -A35IVL55/65
55/70GAN/GAG -A53IVL
GAN/GAG -A70IVL
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
26/88
26 GB
Installation of Indoor Unit
Note: The insulating tube should be connected relia-bly with the sleeve outside the outlet pipe. The drainhose should be slanted downward slightly, without
distortion, bulge or uctuation. Do not put the out-let in the water.
Connecting Indoor and Outdoor Electric Wires
1. Open the front panel.
2. Remove the wiring cover and wire clamp. Make the power connection cord pass through thehole at the back of indoor unit.
3. Connect and x the power connection cord to the terminal board. (As shown in Fig.6)
4. Fix the power connection cord with wire clamp and reinstall wiring cover.
5. Reinstall the front panel.
Fig.6
Wiring Cover
blue black brownyellow-green
outdoor unit connection
NOTE:
All wires between indoor and outdoor units must be connected by the qualied electric
contractor.
Electric wires must be connected correctly. Improper connection may cause malfunction.
Tighten the terminal screws tightly.
After tightening the screws, pull the wire slightly to conrm whether its rm or not.
Make sure that the electric connections are earthed properly to prevent electric shock.
Make sure that all wiring connections are secure and the cover plates are reinstalled properly.Poor installation may cause re or electric shock.
bulge
Flooded
distortion
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
27/88
27 GB
Installation of Indoor Unit
Installation of Indoor Unit
The piping can be output from right, right rear, left
or left rear.
1. When routing the piping and wiring from theleft or right side of indoor unit, cut off the tail-ings from the chassis when necessary (As shownin Fig.7)
1. Cut off the tailing 1 when routing the wir-ing only;
2. Cut off the tailing 1 and tailing 2 whenrouting both the wiring and piping.
2. Take out the piping from body case; wrap thepiping, power cords, drain hose with the tapeand then make them pass through the pipinghole. (As shown in Fig.8)
3. Hang the mounting slots of the indoor unit onthe upper hooks of the mounting plate andcheck if it is rm enough. (As shown in Fig.9)
4. The installation site should be 250cm or moreabove the oor.
Installation of Connection Pipe1. Align the center of the piping are with the re-
lated valve.
2. Screw in the are nut by hand and then tightenthe nut with spanner and torque wrench by re-ferring to the following:
Hex nut diameter Tightening torque (Nm)
6 15~20
9.52 30~40
12 45~55
16 60~65
19 70~75
Tailing 2
Fig. 7
Fig. 8
Fig. 9
Gas side pipe
Gas side pipinginsulation
External connectionelectric wire
Liquid side piping
Liquid sidePiping insulation
Water drainage pipe
Finally wrap itwith tape
Left
Left rear
Right rear
Right
Fixing hook
Mountingplate
Indoor unit piping
Spanner Torquewrench
Taper nut Piping
Mountingplate
Tailing 1
NOTE: Connect the connection pipe to indoor unit at rst and then to outdoor unit. Handlepiping bending with care. Do not damage the connection pipe. Ensure that the joint nut is tight-
ened rmly, otherwise, it may cause leakage.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
28/88
28 GB
Installation of Outdoor Unit
Electric Wiring
1. Remove the handle on the right side plate ofoutdoor unit.
2. Take off wire cord anchorage. Connect and xpower cord and signal control wire (only forheat pump unit ) to the terminal board.Wiringshould t that of indoor unit.
3. Fix the power cord and signal control wire (onlyfor heat pump unit ) with wire clamps and thenconnect the corresponding connector.
4. Conrm if the wire has been xed properly.
5. Reinstall the handle
NOTE:
Incorrect wiring may cause malfunction of spare part.
After the wire has been xed, ensure there is free space between the connection and xing placeson the lead wire.
Air Purging and Leakage Test
1. Connect charging hose of manifold valve to chargeend of low pressure valve (both high/low pressurevalves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.3. Fully open the handle of Lo manifold valve.
4. Open the vacuum pump for vacuumization. At thebeginning, slightly loosen joint nut of low pressurevalve to check if there is air coming inside. (If noiseof vacuum pump has been changed, the reading ofmultimeter is 0) Then tighten the nut.
5. Keep vacuuming for more than 15mins and makesure the reading of multi-meter is -1.0 105pa (-76cmHg).
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of lowpressure valve.
8. Tighten lid of low pressure valve. (As shown inFig.10)
Handle
Indoor unit connection
blue black brown yellow-green
Fig. 10
GAN/GAG -A28IVL
GAN/GAG -A35IVL
GAN/GAG -A53IVL
GAN/GAG -A70IVL
Liquid valve
Vacuum pamp
Gas valve
Manometer
High-pressurevalve (Hi) closed
Charging hose
VacuumpumpGas valve
Liquid valve
Low-pressurevalve (Lo) Open
-76cmHg
Valvo cap
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
29/88
29 GB
Installation of Outdoor Unit
Outdoor Condensation Drainage
(only for Heat pump unit )
During heating operation, the condensingwater and defrosting water should be drainedout reliably through the drain hose.
Install the outdoor drain connector in a 25hole on the base plate and attach the drainhose to the connector, so that the waste wa-ter formed in the outdoor unit can be drainedout. The hole diameter 25 must be plugged.
Whether to plug other holes will be determined bythe dealers according to actual conditions.
Base plate
Drain-water hole
Bottom frame
Drain plug
Drain connecterHose (available commercially,inner dia. 16mm)
Outdoordrain connector
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
30/88
GR30 GB
Check after Installation
Items to be checked Possible malfunction
Has the unit been xed rmly? The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test? It may cause insuffi cient cooling(heating)
Is thermal insulation suffi cient? It may cause condensation.
Is water drainage satisfactory? It may cause water leakage.
Is the voltage in accordance with the ratedvoltage marked on the nameplate?
It may cause electric malfunctionor damage the unit.
Is the electric wiring or piping
connection installed correctly and securely?
It may cause electric malfunction
or damage the parts.Has the unit been securely earthed? It may cause electrical leakage.
Is the power cord specied? It may cause electric malfunctionor damage the parts.
Is the inlet or outlet blocked? It may cause insuffi cient cooling(heating)
Is the length of connection pipesand refrigerant capacity recorded?
The refrigerant capacity is not accurate.
Operation Test
1. Before Operation Test
1. Do not switch on power before installation is nished completely.
2. Electric wiring must be connected correctly and securely.
3. Cut-off valves of the connection pipes should be opened.
4. All the impurities such as scraps and thrums must be cleared from the unit.
2. Operation Test Method
1. Switch on power and press ON/OFF button on the remote controller to start the opera-tion.
2. Press MODE button to select the COOL, HEAT (Cooling only unit is not available), FAN tocheck whether the operation is normal or not.
Check after Installation and Operation Test
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
31/88
31 GR
__________________________________________________ 32-34
____________________________________________ 35-36 ____________________ 37 _________________________________ 38-43 _____________________________________________ 44 ____________________________________________ 45-46 ___________________________________________ 47-49
_______________________________________ 50-52
________________________________________________ 53 _____________________________________ 54-56 ________________________________________ 57 ____________________________________________ 58
. .
.
( ) , , , . .
. .
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
32/88
32 GR
-
( ), . - Service - .
-
-, .
- . -
. / - .
.
, -
Service .
- - . , - - - .
- .
-.
.
- - .
- .
- , .
.
/ . , - - SERVICE .
- .
- , - .
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
33/88
33 GR
: .
- , .
- .
- .
.
.
1 - .
-
- .
-.
,
- . ,
, , - .
-.
- -.
, - -.
.
-. .
.
.
, .
-.
5
( - -
).
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
34/88
34 GR
, .
.
.
.
.
, ,
, ...
.
.
.
CO ( ) .
.
, .
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
35/88
35 GR
:
. , . :
, . 0C, , .
:
. . , .
, .
:
, , , , 8-10.
, .
, ,
. , .
,
Heat (), , ,
, ( 2 ):1. .2. .3. .
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
36/88
36 GR
,
.1. Heat (),
, 60 .
2. Heat (), , 10 .
DB/WB(oC)
DB/WB(oC)
32/23 43/-
27/- 24/18
() 18oC ~ 43oC.
/( ) -7oC ~ 24oC.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
37/88
37 GR
On/Off
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
38/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
39/88
39 GR
17
22
23
25
24
18 19 20 21
MODE MODE - :
AUTO / ,COOL /
DRY / FAN / HEAT /
Up & down swing / -
. .
LOCK +
-, LOCK (-).
.
SET TIME ( ) TIMER, -
ON OFF.
-
.
- . Save SE.
AIR - AIR.
.( ).
LIGHT -
LIGHT.
LIGHT .
TEMP TEMP,
( ),
( ),
( ) -
. - .
SLEEP
SLEEP.
.
17 21
22
23
24
25
19
20
18
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
40/88
40 GR
HEALTH () HEALTH. .
FAN SPEED( ) FAN
(AUTO-LOW-MED-HIGH) ---. .
I FEEL I FEEL. .
8C
TEMP CLOCK . (
).
X-FAN X-FAN. .
TURBO TURBO. .
26 29
30
31
27
28
2930
262731
28
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
41/88
41 GR
ON/OFF: . .
. 2 . AUTO .+ . 2 . AUTO .MODE ,
: AUTO ( ) COOL () DRY () FAN () HEAT ( /) :
(AUTO). AUTO, . ( HEAT ).FAN
: AUTO,, , AUTO.
Auto
SWING / . :
OFF
. SWING. . SWING
.
I FEEL: I FEEL.
. I FEEL .
/
( ) ( ). , . . .
1
2
3
4
5
6
7
8
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
42/88
42 GR
. . . .
SLEEP:
SLEEP ( ). SLEEP . SLEEP .
TEMP: . , . 5 . .
TIMER ON : (). .
00:00 . 5 + . + 1 .
+ 10 . 5 TIMER ON .
CLOCK : CLOCK , 5
+ . 2 + 1 5 10 5 .
CLOCK . .
TIMER OFF : TIMER OFF
. TIMER ON. TIMER OFF.
TURBO: / TURBO. TURBO . . .
LIGHT: . .
X-FAN: .
10 . . X-FAN . X-FAN AUTO-FAN-HEAT.
9
10
11
12
13
14
15
16
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
43/88
43 GR
+ . . + . .
.
MODE -. . MODE - oC oF.
TEMP CLOCK. . TEMP CLOCK . SE. .
TEMP CLOCK. o
C. TEMP CLOCK oC. ( 46oF. ( ). . .
. 4 3 .
(HEALTH). (FAN) Breezing X-FAN.
HEALTH . ( HEALTH, .
1. .
( ).2. .3. 1.5V + -.4. .
. .
, .
.
1
. ,
30 . .
17
18
19
20
21
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
44/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
45/88
45 GR
.
. .
, , ( , ).
. 45 oC . .
: .
( 3 )
.
1. .
() & ().
2. . , ( ) . .
: 45oC .
3.
. .
(.)
(.)
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
46/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
47/88
47 GR
. -
- Service . Service :
.
.
.
.
. . -
3 .
.
( , .) .
- .
.
, -
- . , -
, .
-/ -
Waiting
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
48/88
48 GR
.
- .
.
.
.
.
;
-; ;
( ). ;
; -
;
; ; -
; ;
-. - .
; ; - .
-.
. .
-.
. ,
.
. , -
. .
- .
, .
Breaking off
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
49/88
49 GR
Troubleshooting
.
.
C5: -
F1:
F2:
.
H1:
, - , - SERVICE: SIBA .. . : 210 5386490, fax: 210 5313349.
, - , .( 2 ).
, , . - 3 12 .
- .
- 3 12 -
-, .
. -
.
- .
-
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
50/88
50 GR
!
1. , .
2. . , .
3. , .
4. : , .
5. , ,
.6. .7. ,
.8. ( )
, , , .
9. .10. . .
. : , , . , ,
(. )
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
51/88
51 GR
1. .
.2. , .
3. .
4. , .
5. . 250cm .
6. 1m .
7. .
8. .
9. , .
1.
2. .
3. .
4. .
5. , .
6. .
7. 10m ( 9, 12, 18 & 24), 15m 9, 20m 12 25m 18 24.
8. .
9. .
1. .
2. .
3. .
4. .
5. combustive surface 1,5m.
6. 7. 3mm
.
8. :
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
52/88
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
53/88
53 GR
,
300cm
50cm
50cm
30cm
30cm
200cm
15cm
15cm
15cm
250cm
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
54/88
54 GR
1. . ,
, .2. .
3. , .
1. 55/65 ( 9 &12k ) 55/70 ( 18 &
24k ), ,
.
2. -, .
.
.
1. -
. .
2. .
3. , . - , .
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm 150 mm
150 mm
GAN/GAG -A53IVL
GAN/GAG -A70IVL
Fig.5
GAN/GAG -A28IVLGAN/GAG -A35IVL
55/65
55/70GAN/GAG -A53IVL
GAN/GAG -A70IVL
.
GAN/GAG -A28IVLGAN/GAG -A35IVL
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
55/88
55 GR
1.
2. ( 6)
3. ( & -) .
4.
5.
6
- .
. .
.
. . .
-
. .
:
.
, - . .
-
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
56/88
56 GR
,
( 7)
1
1 2 .
, ( 8)
( 9)
250
1.
2.
(Nm)
6 15~20
9.52 30~40
12 45~55
16 60~65
19 70~75
2
Fig. 7
8
9
.
1
: . . .
.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
57/88
57 GR
1. -
2. . - -.
3. .
4. .
5. .
-
,
1.
2.
3. 4. . -
, . ( 0). .
5. 15. -1.0 105pa(-76cmHg).
6.
7.
8.
, - . 25
.
GAN/GAG -A28IVL
GAN/GAG -A35IVL
GAN/GAG -A53IVL
GAN/GAG -A70IVL
-
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
58/88
58 GR
? ,
?
?
, ?
?
?
?
?
;
1.
1. / .
2. . 3. .
4. .
1. / ON/OFF .
2. MODE COOL, HEAT FAN, .
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
59/88
59
SOMMARIO
Funzionamento e manutenzionePrescrizioni di sicurezza _______________________________________________ 61-63Nome delle parti ________________________________________________________ 64Funzionamento del telecomando _______________________________________ 65-70Funzionamento demergenza _____________________________________________ 71Pulizia e manutenzione _______________________________________________ 72-73Risoluzione dei problemi ______________________________________________ 74-76Suggerimenti per il funzionamento _____________________________________ 77-78
Avvertenze per linstallazioneAvvertenze per linstallazione __________________________________________ 79-81
Schema di installazione __________________________________________________ 82Montaggio dellunit interna ___________________________________________ 83-84Montaggio dellunit externa __________________________________________ 85-86Test di funzionalit e controllo post installazione ______________________________ 87
Mai tentare
Il prodotto che avete acquistato pu differire esteticamente dai prodottiqui raffi gurati. In caso di differenze, fate riferimento al prodotto da voiacquistato.
Questo apparecchio non deve essere utilizzato da persone (bambini compresi) le cuicapacit siche, sensoriali o mentali non ne consentono un utilizzo sicuro, o la cui es-perienza o conoscenza non sono suffi cienti, a meno che non abbiano la supervisioneo abbiano ricevuto istruzioni in merito allutilizzo dellapparecchio da una persona re-sponsabile per la loro sicurezza. I minori devono essere seguiti da un adulto affi nch simantengano a distanza dallunit.
Non gettare questo prodotto in una discarica di riuti. necessaria la raccolta differenziata di questo tipo diriuti, al ne di un trattamento speciale.
Assicurarsi di attenersi alleseguenti istruzioni
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
60/88
60
Prescrizioni di sicurezza
SI prega di leggere le seguenti informazioni prima di mettere in funzione il condizionatore.
AVVERTENZA
In caso di situazioni anomale(ad es. odore di bruciato), in-terrompere immediatamentelalimentazione e contattare ilcentro autorizzato per la ma-nutenzione.
Per lalimentazione deve essereutilizzato un circuito specialeper evitare incendi.
Prima di pulire il condizionatore,interrompere lalimentazione. Lalimentazione deve disporredi un circuito speciale con sal-vavita e la capacit deve essereadeguata. Non spegnere o ac-cendere con rapide successioniil condizionatore.Il collegamento a Y utilizzatoper lalimentazione di questocondizionatore. Se il cavo dialimentazione danneggia-to, deve essere sostituito dalproduttore o da un suo incari-cato o da un tecnico specializ-zato al ne di evitare qualsiasitipo di pericolo.
Se la tensione troppo elevata,gli elementi elettrici possonoessere facilmente danneggiati;se la tensione troppo bassa, ilcompressore vibra fortemente,con conseguente possibile dan-neggiamento del sistema diraffreddamento o del compres-sore stesso, e i componenti elet-trici non funzionano.
Altrimenti, potrebbero vericarsi
scosse elettriche o ferimenti.
Toglierelalimentazione
Non utilizzare ciabatte o schede
elettriche mobili per il collega-
mento.
Interrompere lalimentazionequando il condizionatoresmette di funzionare per unperiodo di tempo prolungato.
Non danneggiare il cavo o uti-lizzare n cavo non specico.
Altrimenti, si possono vericare
incendi dovuti al surriscaldamen-
to del cavo stesso.
Diversamente, la polvere che
si accumulerebbe potrebbe
causare il surriscaldamento, in-
cendi o altri incidenti.
Non azionare il condizionatorecon le mani umide.
Non tagliare o danneggiare ilcavo di alimentazione.Se il cavo di alimentazione o delsegnale sono danneggiati, farlisostituire da un tecnico con uncavo specico.
Potrebbero vericarsi scosse elet-
triche.
Se questa condizione anomala
persiste, il condizionatore potreb-
be essere danneggiato o causare
scosse elettriche o incendi.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
61/88
61
Prescrizioni di sicurezza
Garantire sempreuna effi cace messaa terra.
Non aprire porte o nestrea lungo durante il funziona-mento.
Installare in modo stabilelunit esterna.
Mai salire o appoggiare oggettipesanti sullunit esterna.
Non tentare di riparare das lunit.
Non coprire le griglie di uscitadellaria quando lapparecchio in funzione.
Mantenere materiali combus-tibili ad almeno 1 metro di dis-tanza.
Per ragioni di sicurezza,accertarsi di spegnerelalimentazione prima di es-eguire interventi di manuten-
zione o pulizia o quando ilprodotto non utilizzato perparecchio tempo.
Selezionare la temperaturapi adatta.
La mancata messa a terra
pu essere causa di scosse
elettriche.
Altrimenti la performance
risulter insuffi ciente.
Lunit potrebbe cadere, con
conseguente ferimento delle
persone.
Potrebbe essere causa di dan-
neggiamenti o infortuni.
Una riparazione errata potreb-
be causare scosse elettriche o
incendi. Rivolgersi al centro di
manutenzione autorizzato.
Altrimenti la performance risult-
er insuffi ciente e si potranno
vericare anomalie.Potrebbero vericarsi esplosioni
o incendi.
Laccumulo di polvere potrebbe
causare incendi o scosse elet-
triche.
In questo modo si risparmia en-ergia elettrica.
Mantenere illocale pi frescorispettoallesternodi circa 5 gradi.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
62/88
62
Prescrizioni di sicurezza
Non tagliare o danneggiare il cavo di alimen-tazione o di controllo. Se i cavi sono dan-neggiati, rivolgersi al fornitore o a personalequalicato.
Non inserire le dita o altri oggetti nelle
bocchette di presa o di uscita dellaria.
Non restare direttamente espostiallaria fredda per molto tempo.
Non gettare acqua sul climatizzatore. Nonposizionare una stufa vicino al condiziona-tore.
Non posizionare una stufa vicino alcondizionatore.
Non utilizzare lunit per altri ni, qualimantenere il cibo o asciugare indumenti.
Non esporre animali o piante direttamente
al usso daria.
Potrebbe essere causa di infor-
tunio.
Non salutare.
Potrebbero vericarsi scosse elettriche o anomalie.
Si pu vericare una
tossicosi da CO a
causa della combus-
tione incompleta.
Potrebbe produrre un effetto negativo su di questi.
Per modicare la direzione del getto daria,utilizzare il telecomando per regolare la di-rezione verticale o orizzontale del usso.
Deettore verticale Deettore orizzontale
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
63/88
63
Nome delle parti
Unit interna
Ingresso aria
Ingresso aria
Uscita aria
Uscita aria
Icone visualizzate:
Raffreddamento
Deumidicazione
Riscaldamento
Temperatura impostata Alimentazione
1. Cavo alimentaz.
2. Telecomando
3. Pannello anteriore
4. Filtro5. Deettore orizzont.
6. Tubo a muro
7. Nastro adesivo
8. Cablaggi
9. Tubo di scarico
10. Scarico
Unit esterna
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
64/88
64
Funzionamento del telecomando
ON/OFFPremere per attivare o arrestare il
funzionamento.
SWINGPremere per selezionare langolo dioscillazione.
TIMER ON
Premere per impostare laccensioneautomatica del timer.
-Premere per diminuire le impostazionidi temperatura.
I FEEL(Pagina 68)
CLOCKPremere per impostare lorologio.
+Premere per aumentare le impostazionidi temperatura.
Premere per selezionare la funzioneHEALTH o AIR.
TIMER OFFPremere per impostare lo spegnimentoautomatico del timer.
MODEPremere questo tasto per selezionare lamodalit di funzionamento (AUTO/COOL/
DRY/FAN/HEAT).
SLEEP(Pagina 69)
TURBO(Pagina 69)
FANPremere per impostare la velocit dellaventola.
TEMP(Pagina 69)
LIGHTPremere per attivare o disattivare la luce.
X-FAN(Pagina 69)
1
6
11
2
7
12
3
8
13
4
9
14
5
10
15
16
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
65/88
65
Funzionamento del telecomando
17
22
23
25
24
18 19 20 21
Icona MODESe si preme il tasto MODE, comparelicona attuale della modalit operativa
AUTO, COOL,DRY, FAN or HEAT
solo per i modelli con pompa di calore).
Icona oscillazione su e gi: visualizzata premendo
il tasto oscillazione orizzontale.Premere nuovamente questotasto per azzerare il display.
Icona LOCK visualizzata premendosimultaneamente i tasti +e -. Premerli nuovamente perazzerare il display.
Display SET TIME:Dopo aver premuto il tasto TIMER,lampeggiano ON o OFF. Questaarea indica lora impostata.
DISPLAY digitale:Questa area indica la temperaturaimpostata. In modalit SAVE, sarvisualizzato SE.
Icona AIR visualizzata premendo il
tasto AIR. Premere nuovamente
questo tasto per azzerare il display.Nota: funzione eseguibile solo sualcuni modelli.Questa funzione non e disponibilesu questo modello.
Icona LIGHT visualizzata premendo il tasto
LIGHT. Premere nuovamenteLIGHT per azzerare il display.
Icona TEMPPremendo il tasto TEMP,
vengono visualizzati circolarmente
(imposta temperatura),
(temperatura ambiente interna)
(temperatura ambiente esterna) e
schermo vuoto.
Nota: funzione eseguibile
solo su alcuni modelli.
Questa funzione non e disponibile su
questo modello
Icona SLEEP
visualizzata premendoil tasto SLEEP. Premerenuovamente questo tasto perazzerare il display.
17 21
22
23
24
25
19
20
18
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
66/88
66
Funzionamento del telecomando
Icona HEALTH visualizzata premendo il tasto
HEALTH. Premere nuovamentequesto tasto per azzerare ildisplay.
Display FAN SPEEDPremere il tasto FAN perselezionare limpostazione divelocit ventola desiderata (AUTOLow-Med-High). La vostra selezionesar visualizzata sul pannello LCD,tranne la modalit AUTO fan speed.
Icona I FEEL
visualizzata premendo iltasto I FEEL. Premere nuovamentequesto tasto per azzerare il display.
Icona 8C Heating visualizzata premendo
contemporaneamente i tastiTEMP e CLOCK nella modalit diriscaldamento.Questa funzione non e disponibilesu questo modello.
Icona X-FAN visualizzata premendo
il tasto FAN. Premere nuovamentequesto tasto per azzerare il display.
Icona TURBO visualizzata premendo il
tasto TURBO. Premere nuovamentequesto tasto per azzerare ildisplay.
26 29
30
31
27
28
2930
262731
28
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
67/88
67
Funzionamento del telecomando
Descrizione telecomando
ON/OFF:
Premere questo tasto per attivare lunit. Premere ancora questo tasto per spegnere lunit.
Premere questo tasto per diminuire la temperatura impostata. Tenerlo premuto per 2 secondiper diminuire rapidamente la temperatura. In modalit AUTO, la temperatura impostata non regolabile.+Premere questo tasto per aumentare la temperatura impostata. Tenerlo premuto per 2 sec-ondi per aumentare rapidamente la temperatura. In modalit AUTO, la temperatura impostatanon regolabile.MODEAd ogni pressione del tasto selezionata un modalit, in sequenza da AUTOMATICO, a RAF-
FREDDAMENTO, a DEUMIDIFICAZIONE, a RISCALDAMENTO, a VENTILAZIONE come qui indi-cato:
* Nota: Solo per modelli con funzione riscaldamento.
Dopo laccensione, lunit parte per preimpostazione in modalit AUTO. In questa modalit, latemperatura impostata non visualizzata sul display LCD e lunit selezione automaticamente lamodalit di funzionamento in base alla temperatura ambiente, al ne di renderla adeguata. (Nelleunit a solo raffreddamento, con il segnale per il riscaldamento non avverr alcuna operazione.)FANQuesto tasto serve per impostare la velocit del ventilatore nella sequenza che inizia conAUTO, , e ritorna ad AUTO.
Auto
Velocit bassa Velocit media Velocit altaSWINGPremere questo tasto per impostare langolazione di oscillazione orizzontale (su e gi), chevaria circolarmente come qui indicato
OFF
Questo telecomando universale. Se viene inviato un commando , lunitesegue il commando come
indica le oscillazioni del deettore come:
I FEEL:Premere questo tasto per attivare la funzione I FEEL. Lunit regola automaticamente la tem-peratura in base alla temperatura rilevata. Premere questo tasto nuovamente per cancellarela funzione I FEEL.
/
Premere questo per attivare e disattivare le funzioni di puricazione e pulizia in modalit difunzionamento. Premere questo tasto per la prima volta per avviare la funzione di pulizia; loschermo LCD visualizza Premere questo tasto per la seconda volta per avviare la funzione
di pulizia e puricazione contemporaneamente; lo schermo LCD visualizza e . . Premerequesto tasto una terza volta per uscire dalle funzioni di pulizia e puricazione contempo-raneamente. Premere questo tasto per la quarta volta per avviare la funzione di pulizia; loschermo LCD visualizza . Premere nuovamente questo tasto per ripetere loperazione.(Questa funzione disponibile solo per alcuni modelli).
1
2
3
4
5
6
7
8
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
68/88
68
Funzionamento del telecomando
SLEEP:Premere questo pulsante per attivare la modalit Notturna SLEEP. Premere nuovamentequesto pulsante per disattivare questa funzione. Questa funzione attivabile in modalit di
Raffreddamento (COOL) e Riscaldamento (HEAT) per mantenere la migliore temperatura du-rante le ore notturne.
TEMP:Premendo questo pulsante, possibile vedere la temperatura impostata e la temperatura in-terna. Limpostazione sul telecomando avviene circolarmente secondo il seguente schema:
Quando selezionato sul telecomando o no display, la temperatura visualizzata sullunitinterna quella impostata con il telecomando. Quando selezionato con il telecomando, latemperatura visualizzata sullunit interna quella ambiente. 3secondi dopo o se nei seguenti3 secondi viene ricevuto unaltro segnale dal telecomando, sullunit interna viene visualizzatala temperatura impostata.Attenzione: Questo modello non ha la visualizzazione della temperatura esterna . Quando si accende lunit, automaticamente viene visualizzata la temperatura impostata.
TIMER ON :Premere questo tasto per impostare lora di accensione automatica (auto-ON). Per annullarequesto programma, premere ancora il tasto. Dopo aver premuto questo tasto, la visualizzazi-one sparisce e ON lampeggia. 00:00 visualizzato per limpostazione dellorario di accen-sione. Entro 5 secondo, premendo + o si regola lorario desiderato. Ad ogni pressione di unodei tasti cambia limpostazione dellorario di 1 minuto. Tenere premuto il tasto per cambiare
rapidamente limpostazione di 1 minuto e poi di 10 minuti. Entro 5 secondi dallimpostazione,premere TIMER ON per confermare.
CLOCK :Premere CLOCK, lampeggia. Entro 5 secondo, premendo + o si regola lorario presente.Tenere premuto uno dei due tasti per 2 secondi per aumentare o diminuire lora di 1 minutoogni 0.5 secondi e poi di 10 minuti ogni 0.5 secondi. Durante il lampeggiamento dopolimpostazione, premere CLOCK per confermare limpostazione. Poi sar costantemente visu-alizzato .
TIMER OFF :Premere questo tasto per impostare lora di spegnimento automatico (auto-Off). Per cancel-lare questo programma, premere ancora il tasto. Limpostazione TIMER OFF identica a quella
per TIMER ON.TURBO:Premere questo tasto per attivare o disattivare la funzione turbo, che consente allunit diraggiungere la temperatura preimpostata in brevissimo tempo. In modalit COOL, lunit sof-a aria fredda a velocit massima. In modalit HEAT, lunit soffi a aria calda fredda a velocitmassima.
LIGHT:Premere il tasto LIGHT per attivare la luce del display e premerlo nuovamente per spegnerla.
Se la luce accesa, viene visualizzato Se la luce spenta, sparisce.
X-FAN:Premendo il tasto X-FAN in modalit COOL o DRY, licona viene visualizzata e la ventolainterna continua a funzionare per 10 minuti al ne di asciugare lunit interna anche dopo lospegnimento. Dopo laccensione, lunit parte per preimpostazione in modalit X-FAN. X-FANnon disponibile in modalit AUTO, FAN e HEAT.
9
10
11
12
13
14
15
16
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
69/88
69
Funzionamento del telecomando
Combinazione dei tasti + e -: Premere contemporaneamente i pulsanti + e - per bloccare o
sbloccare la tastiera. Se il telecomando bloccato, viene visualizzato In questo caso, pre-mendo qualsiasi tasto, lampegger tre volte.
Combinazione di MODE e tasto -: Passaggio dalla modalit Fahrenheit a centigradi Con lunitspenta, premere i tasti MODE e - simultaneamente per passare da C a F e viceversa.
Combinazione dei tasti TEMP e CLOCK: Funzione Energy-saving (risparmio energetico) PremereTEMP e CLOCK contemporaneamente in modalit COOL per avviare la funzione risparmioenergetico. Il tubo Nixie sul telecomando tube visualizza SE. Ripetere loperazione per usciredalla funzione.
Combinazione dei tasti TEMP e CLOCK: Funzione 8C Heating (riscaldamento 8C) PremereTEMP e CLOCK contemporaneamente in modalit HEAT per avviare la funzione 8C Heating.Il tubo Nixie sul telecomando tube visualizza e la temperatura selezionata di 8C. Ripetereloperazione per uscire dalla funzione.
Funzione Back-lighting (retroilluminazione)Lunit si accende per 4 s quando alimentata per la prima volta e 3 s successivamente.
Sostituzione delle batterie1. Togliere il coperchio dalla parte posteriore del telecomando. (Come indicato in gura)2. Estrarre le batterie esauste.3. Sostituirle con due batterie alcaline nuove del tipo AAA da1,5V, rispettando la polarit.4. Rimontare il coperchio del vano batterie.
Note: Quando si sostituiscono le batterie, non utilizzare batterie
vecchie o di diverso tipo, altrimenti si possono vericare
anomalie. Se il telecomando non sar utilizzato per un lungo periodo
i tempo, estrarre le batterie per evitare il danneggiamentodovuto a perdita di liquido dalle batterie.
Assicurarsi di utilizzare il telecomando entro la gamma diricezione.
Il telecomando va mantenuto ad almeno 1 m. di distanza datelevisori o impianti stereo.
Se il telecomando non funziona correttamente, provare arimuovere le batterie e reinserirle dopo 30 secondi. Se ancoranon funziona correttamente, sostituire le batterie.
17
18
19
20
21
Disegno per lasostituzionedelle batterie
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
70/88
70
Funzionamento demergenza
Funzionamento demergenza
Se il telecomando non si trova o danneggiato,
utilizzare linterruttore manuale presente sullunitprincipale. In quel caso, lunit funzioner inmodalit AUTO e limpostazione della temperaturao la velocit della ventola non potranno esseremodicate. Linterruttore manuale funziona nelseguente modo:
Accendere lunit:Premere AUTO/STOP per selezionare la modalit AUTO.Il microprocessore selezioner la modalit (COOL, HEAT,
FAN) automaticamente, in base alla temperatura ambi-ente, al ne di creare un ambiente confortevole.
Spegnere lunit:Premere AUTO/STOP per disattivare lunit.
La modalit di funzionamento descritta nella tabellaseguente.
Modalit Modello Impostazione dellatemperatura
Quantit delgetto daria
AUTO COOLING 25(COOL, FAN) AUTO
AUTO POMPA DI CALORE 25(COOL, FAN) AUTO
AUTO POMPA DI CALORE 20(HEAT) AUTO
Questo interruttore deve essere utilizzato quando il tel-ecomando non utilizzabile.
Interruttore manuale
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
71/88
71
Pulizia e manutenzione
Attenzione
Scollegare il cavo di alimentazione prima di procedere alla pulizia e alla manutenzione. Non gettare acqua sulle unit per la pulizia, in quanto possono vericarsi scosse elettriche. Asciugare le unit con un panno morbido e asciutto, o con un panno leggermente inumidito
con acqua o detergente (non con un liquido volatile come diluente o benzina).
Pulizia del pannello frontale
Rimuovere il pannello frontale. Immergere un panno in acqua pi fredda di 45C e asciugarlo. Poipulire la parte sporca del pannello frontale.Nota: Non immergere il pannello frontale in acqua, per proteggere i componenti del microchipe lo schema elettrico.
Pulizia del ltro aria (ogni 3 mesi)
1. Togliere il ltro dellariaSollevare il pannello frontale.Tirare il ltro verso il basso per estrarlo,come indicato in g. (a, b).
2. Pulire il ltro dellaria.Aspirare la polvere.Se i ltri sono sporchi, lavarli con acqua tiepidae detergente.Asciugare i ltri al riparo dalla luce diretta.Nota:Mai utilizzare acqua a temperatura superiore a 45Cper pulire i ltri, per non causare deformazioni o perdita dicolore.
3. Reinserire i ltri dellaria.Seguire la direzione della freccia.Chiudere il pannello.
(Fig.a)
(Fig.b)
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
72/88
72
Pulizia e manutenzione
Controlli prima delluso1. Assicurarsi che nessun oggetto ostruisca le prese di uscita ed
entrata dellaria.2. Vericare che le batterie del telecomando siano state sostitu-
ite.3. Accertarsi che il supporto dellunit esterna non sia dan-
neggiato. Se danneggiato, rivolgersi ad un tecnico.
Manutenzione dopo luso
1. Interrompere lalimentazione2. Pulire il ltro e le unit interna ed esterna.3. Eliminare polvere e ostruzioni dallunit esterna.4. Riverniciare i punti arrugginiti presenti sullunit esterna onde prevenire lestensione del
fenomeno.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
73/88
73
Risoluzione dei problemi
AttenzioneIl condizionatore non deve essere riparato dallutente. Riparazioni errate possono causare scosse
elettriche o incendi; rivolgersi quindi al centro assistenza autorizzato. I seguenticontrolli prima di rivolgersi al centro assistenza possono far risparmiare tempo e denaro.
Lunit non funziona:
Si percepiscono odori:
Rumore di acqua che scorre:
In modalit COOL fuoriesce nebbiolina.
Rumore sordo:
Potrebbe essere stata riaccesa subito dopouno spegnimento. Si tratta di una funzionalitdi protezione dellunit. Attendere 3 minuti.
Alcuni odori possono provenire dallunit in-terna. Possono derivare da odori presenti nellocale (mobili, tabacco, ecc.) che sono stati as-pirati dal condizionatore.
Rivolgersi al centro assistenza autorizzato setali odori persistono.
Questo rumore causato dal liquido refriger-ante che scorre allinterno dellunit.
In questa modalit, una leggera nebbiolina
pu fuoriuscire se la temperatura de locale eil tasso di umidit sono molto elevati. Dopoun periodo di tempo, la nebbiolina scompar-ir con la diminuzione della temperatura edellumidit.
Questo suono pu essere dovuto alla frizionecausata dallespansione o contrazione deipannello o di alter parti a causa della temper-
atura.
Sintomo Risoluzione dei guasti
Attesa
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
74/88
74
Risoluzione dei problemi
Non si riesce ad accendere lunit:
Leffetto di raffreddamento/riscaldamento scarso:
Il telecomando non funziona:
Perdite di acqua dallunit interna:
Perdite di acqua dallunit esterna:
Lunit interna fa rumore:
Lalimentazione stata tolta?
Il cavo allentato? (se il caso) Il salvavita saltato? La tensione troppo alta o troppo bassa? (Vericata da professionisti) Il Timer usato correttamente?
La temperatura impostata adeguata?
La presa o lo sato dellaria sono bloccati?
Il ltro sporco?
Vi sono porte o nestre aperte?
La ventola a bassa velocit?
Ci sono fonti di calore nella stanza?
Vericare se vi sono interferenze magneticheo elettriche nelle vicinanze dellunit che pos-sono incidere sul funzionamento del teleco-mando. In questo caso, staccare e reinserire ilcavo.
Vericare che il telecomando sia nel raggio diricezione e che non sia ostruito. Vericare lostato delle batterie e sostituirle se necessario.
Vericare che il telecomando non sia dan-neggiato.
Lumidit elevata.
Uscita dacqua di condensa.
Il tubo di scarico allentato.
Durante il raffreddamento, si genera condensaattorno ai tubi e alle giunzioni.
Durante lo sbrinamento, lacqua sciolta fuoriesce. Durante il riscaldamento, lo scambiatore di calore
gocciola.
Il suono proviene della ventola o del rel del com-
pressore che si avviano o si arrestano. Durante lavvio o larresto dello sbrinamento, sisente il rumore del refrigerante che uisce in di-rezione contraria.
Sintomo Risoluzione dei guasti
Breaking off
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
75/88
75
Troubleshooting
Sintomo Risoluzione dei guasti
Lunit interna non emette aria:
Umidit sulla bocchetta di uscita dellaria:
C5: Anomalia del ponticello del connettore:
F1: Anomalia sensore temperatura interna.
F2: Anomalia sensore temperaturaevaporatore.
Sbrinamento o o modalit di ritorno dellolio.
Si avverte un rumore stridente in sede di fun-zionamento.
Forti odori durante il funzionamento. Perdita di acqua dallunit.
Linterruttore aria o il salvavita saltano con fre-quenza. Acqua o altro liquido gettato sullunit. Il cavo e la presa di alimentazione sono sur-
riscaldati.
Arrestare il funzionamento e
togliere lalimentazione.
H6: Blocco del ventilatore dellunit interna.
Nel caso si verichi uno dei seguenti malfunzionamenti, fermare lapparecchio,togliere lalimentazione e contattare lassistenza tecnica.
In modalit HEAT, quando la temperatura
dello scambiatore di calore interno moltobassa, lunit non produce aria per impedire ladiffusione di aria fredda. (Entro 2 min)
In modalit HEAT, quando la temperatura es-terna bassa o lumidit elevata, si formadella brina sullo scambiatore esterno. Lunit sisbrina automaticamente e lunit interna nonemette aria per 3-12 min.
Durante lo sbrinamento, pu fuoriuscire ac-qua o vapore.
In modalit DRY, la ventola interna si fermaper 3-12 min. per evitare la vaporizzazione di
condensa.
Se lunit in funzione in condizioni di umiditelevata per un periodo prolungato, si formerumidit sulla griglia di uscita dellaria e goc-cioler.
Vericare se il ponticello del connettore facontatto correttamente. Se il PCB deve esseresostituito, estrarre quello vecchio e inserirneuno nuovo.
Vericare se il sensore temperatura interna collegato correttamente.
Vericare se il sensore temperatura evapora-tore collegato correttamente.
E normaleIl led HEAT lampeggia per 0,5 secondi e resteracceso per 10secondi
Controllare se le connessioni del ventilatore allascheda elettronica sono a posto.Sostituire il ventilatore o la scheda elettronica
se questa guasta.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
76/88
76
Suggerimenti per il funzionamento
Raffreddamento
PRINCIPIO:I condizionatori assorbono il calore presente nellaria e lo trasmettono allunit esterna inmodo da diminuire la temperatura ambiente. La capacit di raffreddamento aumenta odiminuisce in base alla temperatura esterna.FUNZIONE ANTIGELO:Se lunit funziona in modalit COOL con temperatura ambiente bassa, si pu formareghiaccio sullo scambiatore di calore. Quando la temperatura dello scambiatore di caloreinterno scende al di sotto dello zero, il compressore smette di funzionare per proteggere lunit.
Funzionamento del riscaldamento
PRINCIPIO:* I condizionatori assorbono calore dallesterno e lo trasmetto allunit interna, aumentando la
temperatura interna. La capacit di riscaldamento minore se la temperatura esterna bassa.
SBRINAMENTO:* Quando la temperatura esterna bassa ma lumidit elevata, si pu formare ghiaccio sullunit
esterna durante il funzionamento prolungato, incidendo sulla capacit di riscaldamento. Il con-dizionatore pu fermarsi durante lo sbrinamento.
* Durante lo sbrinamento automatico, i motori delle ventole dellunit interna ed esterna si fer-mano.
* Durante lo sbrinamento, la spia dellunit interna lampeggia, e dallunit pu fuoriuscire va-pore. Questa non unanomalia.* AL termine dello sbrinamento, la modalit di riscaldamento riprende automaticamente.
FUNZIONE ANTIRAFFREDDAMENTO:In modalit HEAT, la ventola interna non funziona per impedire la fuoriuscita di aria fredda(per 2 minuti) se lo scambiatore di calore interno on raggiunge una certa temperatura in unadelle 3 seguenti condizioni:1. Inizia il riscaldamento; 2. Al termine dello sbrinamento automatico; 3. Riscaldamento abassa temperatura.
FLUSSO DARIA LEGGERONelle seguenti condizioni, lunit interna pu emettere un usso daria leggero e il deettoreorizzontale ruoter in una certa posizione:1. In modalit Heat, lunit accesa e il compressore non raggiunge la condizione di avvio.2. In modalit HEAT, la temperatura raggiunge il valore impostato e il compressore si fermato
per circa 1 minuto.
8/10/2019 Akira Premium Gan_g-51cc2c9ec4085
77/88
77
Suggerimenti per il funzionamento
Intervallo della temperatura di esercizio
Temperatura interna DB/WB(oC)
Raffreddamento 18C~ 43C
Riscaldamento -7C~ 24C
Lintervallo di temperatura di funzionamento (temperatura esterna) per le unit cheproducono raffreddamento e riscaldamento -7C~ 43C.
SUGGERIMENTI PER IL RISPARMIO ENERGETICO
* Non eccedere con il riscaldamento o il raffreddamento. Impostando la temperatura ad un livello moderato aiuta a risparmiare energia.* Oscurare le nestre con imposte o tende. Bloccare la luce del sole e laria esterna favorisce il raffrescamento (o il riscaldamento).* Pulire i ltri ogni due settimane. I ltri intasati determinano un funzionamento ineffi ciente e uno spreco di energia.
SUGGERIMENTI PER LUMIDIT RELATIVA
La condensa si forma facilmente nella boc