1/1
LIN
1/1
1/1
LIN
1/12/2
1/1
FUR.
2/2
1/1
1/1
02
A4-1.3
H
H
S
S
S
S
S
S
SS
S
S
S
S C
S
S
S
S
S
SS
S
S
S
C C
HS
SELEC
T.
S
1/1
1/1
2/2
FUR.
2":12
2":12
3/8:12 SLOPE
2":12
2":12
2":12
3/8
:12 S
LOPE
3/8
:12 S
LOPE
3/8:12 SLOPE
3/8:12 SLOPE1 1/2:12 SLOPE
3/8
:12 S
LOPE
3/8
:12 S
LOPE
3/8
:12 S
LOPE
3/8:12 SLOPE
3/8:12 SLOPE
3/8:12 SLOPE
3/8:12 SLOPE
D.S.
D.S.
D.S.
D.S.
3/8
:12 S
LOPE
1/4:12
SLO
PE1/
4:12
SLO
PE
1/4:12 SLOPE1/4:12 SLOPE
D.S.
1/4:12
SLO
PE1/
4:12
SLO
PE
3/8:12 SLOPE
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
PV
AV
PV
AV
PV
AV
PV
AV
PV
AV
PV
AV
PV
AV
PV
AV
PV
AV
1/4:12
SLO
PE
1/4:12
SLO
PE
1/4:12
SLO
PE
1/4:12
SLO
PE
2'-0" TYP.
2'-0" TYP.
4'-0"
4'-0"2'-0" TYP.
2'-0" TYP.
1'-6" TYP.
4'-6" TYP.2'-0" TYP.
21'-9"
5'-83
4 "
21'-9"
2'-0"
9"
6'-7"
11'-912 "
13'-2 12 "
10'-7 12 "
1'-6" TYP.
1'-6" TYP.
4'-6" TYP.
3'-6" TYP.
10'-5"
10'-111 2"
1'-512 "
4'-0"
1'-51 2"
4'-11 12 "
3'-6" TYP.1'-6" TYP.
4'-0" TYP.
3'-6" TYP.
1'-6" TYP.
SPLAYED
4'-6"
2'-2 12 "4'-11 12 "
1'-10"
1'-10"
4'-6" TYP.
3'-6" TYP.
1'-6" TYP.
10'-101 2"
14'-93 4"
30'-0"
18'-9"
10'-5"
13'-10 14 "
10'-5"
4'-9
12 "
32'-2 12 "
1'-8"
4'-0"
4'-0"1'-0"
2'-101 2"
4'-0"
1'-5 12 "
1'-81 2"
1'-51 2"
4'-0"
2'-612 "
5'-0"
ROOF TYPE "E29"1,425 S.F.
ROOF TYPE "E16"959 S.F.
ROOF TYPE "E42"2,602 S.F.
ROOF TYPE "P21"9,858 S.F.
ROOF TYPE "P21"9,920 S.F.
A9-7.502
TYP.
A9-7.517
PLATFORM -03
A9-7.517
PLATFORM -04
A9-7.517
PLATFORM -04
A9-7.517
PLATFORM -05
42" MIN. HEIGHT PARAPETWALL ADJACENT TO
GARAGE, TYPICAL
42" MIN. HEIGHT PARAPETWALL ADJACENT TO
GARAGE, TYPICAL
03
04
17
20
19
17
20
19
04
03
03
24
07
23
03
05
15
25
25
A9-7.517
PLATFORM -03
A
A9-7.319
TYP.
A9-7.319
TYP.
A
NOTE THAT ALTERNATE ROOF VENTS THATPOSSESS THE SAME NET FREE AREA ASTHOSE USED TO CALCULATE THE ATTICVENTILATION MAY BE SUBMITTED TO THEARCHITECT FOR REVIEW AND APPROVAL.
NOTE THAT ALTERNATE ROOF VENTS THATPOSSESS THE SAME NET FREE AREA ASTHOSE USED TO CALCULATE THE ATTICVENTILATION MAY BE SUBMITTED TO THEARCHITECT FOR REVIEW AND APPROVAL.
A
SHEET NO.
SHEET TITLE
PROJECT NO.
CHECKED:
PLOT DATE:
DRAWN:
COLORADO # : OREGON # :
NEVADA # : ARIZONA # :
CALIFORNIA # :
36404356
283827259
C15528
S a n D i e g o , C a l i f o r n i a
A R C H I T E C T S , I N C .
F a r a m a r z J a b b a r i , A I A
S o r r e n t o V a l l e y R o a d
T e l : ( 8 5 8 ) 7 9 2 - 5 9 9 7F a x : ( 8 5 8 ) 7 9 2 - 5 8 5 8
9 2 1 2 1-1 3 1 3
S u i t e 501
1 1 8 5 5
A R K
ADDRESS:
"PER
MIT
SET
2015 0
6-1
1"
2014-056
June 15, 2015
LAL, VM, AE, SH, NM
FJ, JM
PROJECT PHASE ____
MILESTONE:___
X
X
X
X
X
----
----
----
----
----
ALL
IDEA
S, D
ESIG
N A
RRANG
EMEN
TS A
ND
PLA
NS IN
DIC
ATE
D O
R R
EPRES
ENTE
D B
Y TH
IS D
RAW
ING
ARE
OW
NED
BY
AND
THE
PRO
PERTY
OF
ARK
ARCHIT
ECTS
, IN
C. AND
WER
E CREA
TED
EVO
LVED
AND
DEV
ELO
PED
FO
R U
SE
ON A
ND
IN C
ONNEC
TIO
N W
ITH T
HE
SPE
CIF
IED
PRO
JECT.
NO
NE
OF
SUCH ID
EAS A
RRANG
EMEN
TS O
R P
LANS S
HALL
BE
USED
BY
OR D
ISCLO
SED
TO
ANY
PERSO
N F
IRM
OR C
ORPO
RATI
ON F
OR A
NY
PURPO
SE
WHATS
OEV
ER W
ITHO
UT
THE
WRIT
TEN P
ERM
ISSIO
N O
F ARK
ARCHIT
ECTS
, IN
C.
X ----
X ----
X ----
ASECOND SUBMITTAL06/08/2015
No. 7288093-0301
Exp.___________ 05/31/16
J A B B A R IF A R A M A R Z
BLDG 1 ROOFPLAN SECTION C
AVPV
SHEET METAL FLASHING OVER PLYWOODSHEATHING
20"X30" MIN. ATTIC ACCESS PANELPAINTED TO MATCH ADJACENT FIELDCOLOR W MAINTENANCE LOCKSET.
GUTTER AND DOWNSPOUT (WHERE OCCURS),TYP.
HARD-DUCTED SOFFIT VENT TO ROOF / CEILINGASSEMBLY ABOVE
CHASE WALL AT MECHANICAL PADS PER DETAIL18/A9-7.3
ROOF MOUNTED HVAC UNITS PER MECHANICALPLANS, TYP.
4" CANT STRIP PER DETAILS 02,06/A9-7.3
MECHANICAL EQUIPMENT PADS W NOISE ANDVIBRATION ISOLATION PAD UNDER EACHCOMPRESSOR UNIT,PER DETAIL 17/A9-7.3 TYP.
HANDRAIL AND GUIDE FOR TEMPORARY ROOFACCESS LADDER
ROOF SCUPPER AND OVERFLOW PER DETAILS 10,11/A9-7.3
STUCCO FINISH @ ALL EXTERIOR WALLLOCATIONS. STEEL TROWELED FINISH FASCIA @RAKE & EAVE LOCATIONS, TYP.
20"X30" MIN. ATTIC ACCESS PANEL ATLOCATIONS WITH 30" MIN. CLEAR OVERHEAD
NOT USED
GABLE VENT PER DETAIL
NOT USED
FIREWALL TERMINATION APRON IN ACCORDANCEWITH SECTION 706.6.4
ROOF DRAIN AND OVERFLOW PER DETAILS
LINE OF WALLS BELOW, TYP.
CRICKET PER DETAILS 03,07/A9-7.3
ROOF TIE OFF EYE, BOOT FLANGE, AND WATERPROOFING CAP PER OSHA STANDARS, TYP.
NOT USED
ROOF SYMBOLS
2-HR. FIRE WALL
DRAFTSTOPDRAFTSTOP
ROOF KEY NOTES
ROOF GENERAL NOTES:NOTE:
1. DRAFTSTOPPING IS NOT REQUIRED IN THE ATTICSPACE OF BUILDINGS EQUIPPED THROUGHOUTWITH AN AUTOMATIC SPRINKLER SYSTEM INACCORDANCE WITH SECTION 903.3.1.1 (NFPA 13)PER SECTION 717.4.2 (EXCEPTION 2); HOWEVER,DRAFTSTOPPING REQUIREMENTS ARE TO BECONFIRMED WITH THE FIRE PROTECTION DESIGN.
2. ATTIC VENTILATION IS REQUIRED, REFER TOCALCULATIONS, THIS SHEET.
3. ROOFING SHALL BE INSTALLED IN ACCORDANCEWITH ALL MANUFACTURER'S RECOMMENDATIONSAND SPECIFICATIONS.
4. ALL BUILT-UP ROOFS SHALL BE MINIMUM CLASS"B" FIRE RATED.
5. COORDINATE WITH MECHANICAL DRAWINGS FOREXACT ROOFTOP MECHANICAL LOCATIONS ANDWEIGHT OF MECHANICAL EQUIPMENT.
6. SEE MECHANICAL PLANS FOR MECHANICAL UNITDETAILS AND MOUNTING DETAILS.
7. THE VALLEYS OF ROOF CRICKETS SHALL NOT BELESS THAN 18" PER FOOT SLOPE.
8. NO ROOF PENETRATIONS ARE ALLOWED WITHIN4'-0" HORIZONTAL OF ALL FIREWALLS. SEEHATCHED AREAS AND LEGEND, TYP.
9. SURFACE OVER LIVING SPACES SHALL BESLOPED MIN. 38" PER FOOT.
10. THE ENTIRE BUILDING SHALL BE PROVIDED WITHNOT LESS THAN CLASS "B" ROOF COVERING.
11. FLAT ROOF TRUSS HEAL HEIGHT IS TO BE 16" ATITS SMALLEST STARTING LOCATION
12. ROOF TRUSS VOID SPACE IS TO BE LESS THAN36" DEEP AT ALL TIMES.
13. SEE MECHANICAL PLANS FOR COMPRESSOR UNITLAYOUTS, TYP.
14. RESIDENTIAL SARNAFIL HIGH ROOFS SHALL HAVEA 5'-0" HIGH EAVE OVERHANG FROM FURRING, &1'-0" RAKE & LOW EAVE OVERHANGS, TYP.
15. BUILT UP ROOFING SHALL HAVE A 2'-0"OVERHANG TO EDGE OF TRUSS, & A 18"HORIZONTAL OVERLAP OF ADJACENT WALLS, TYP.U.N.O. SEE DETAIL ON SHEET A9-7.4
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
DRYER VENT TERMINATION AT ROOF FOR TOPFLOOR UNITS ONLYEAVE VENT PER 04, 05/A9-7.1, ANDCALCULATIONS, TYP.
NOT USED
WALKING PADS PER SPECIFICATIONS. MATERIALTO BE CONFIRMED WITH ROOFING MANUFACTURER
GAF TPO 60 MIL. "EVERGUARD" SINGLE PLYROOFING SYSTEM
ROOF PARAPET WALL @ 42" A.F.S. OR 5'-0"ABOVE T.O.P. WHICHEVER IS TALLER, U.N.O. SEEELEVATIONS & TYPICAL DETAILS
D.S.
O.S.
D.S.
S.B.
ROOF SPLASHBLOCK OVER EPDM PAD PERDETAIL 09/A9-7.3, TYP.
WALKING PADS PER SPECS.
27
26
AREA OF 1HR HORIZONTAL RETURN@ FIREWALL. NO PENETRATIONSALLOWED WITHIN 4'-0" OFFIREWALLS WITHOUT A 30"PARAPET EXTENSION PER CBCSECTION 706.6
ACTIVE VENTILATION PRODUCTS OREQUAL FLAT ROOF VENT SYSTEM.POP VENT INTAKE & AURAVENTILATOR EXHAUST, TYP.
WALL VENT (ABOVE RATED CEILING MEMBRANE)PER DETAIL 06/A9-7.2
28
GUARD AT ROOF - IF OCCURS, SEE DETAIL20/A9-5.2
29
OVERFRAMED CRICKETING @ 1/4":1'-0"SLOPE MIN. PER DETAILS 03, 07, 05,15, 16/ A9-7.3. OPTIONAL SOLIDSLOPED FOAM/RIGID INS. CRICKETS
SLOTTED SOFFIT EAVE VENTS PERCALCULATIONS. SEE ELEVATIONSFOR LENGTH & TERMINATION
MAIN 6"x4"SCUPPER DRAIN WDOWNSPOUT & LEADER HEAD PER 10,A9-7.3
6"x4" OVERFLOW SCUPPER SIM.TO DETAIL 11/ A9-7.3
DOWNSPOUT AND SPLASHBLOCK PERDETAIL 09/A9-7.3
AREA OF RAISED PLATES &CEILINGS @ 12'-0' A.F.F.
AREA OF RAISED PLATES & DROPSOFFITS @ 9'-0' A.F.F.
MECHANICAL SCREEN SYSTEM PERDETAILS 08, 07 / A9-7.2
SC. = SCUPPER
RIDGE VENT30
3' HIGH WALL FOR SATELLITE DISH MOUNTS31
A
BLDG 1 ROOF PLAN SECTION C1/8" = 1'-0"
01
W E
S
N
3320
WES
T
KEY PLAN
NORRIS
VIE
W L
ANE
8660 SOUTH