800.962.9473 www.encorewire.com52
TYPE MC-COPPER CONDUCTOR STEEL ARMOR/XHHW-2 INNERS
ENGINEERING SPECIFICATIONS:Standards:Underwriters Laboratories Standards UL-44, UL-1569 for type MC, Federal Specification A-A59544,IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test, and the National Electric Code (NEC); ARRA 2009; Section 1605 "Buy American" Compliant
Applications: Type MC cable shall be permitted as follows: • Permitted use for service power and feeder distribution in industrial, commercial, and multi-residential buildings • Acceptable for power, lighting, control, and signal circuits • Allowable in concealed or exposed systems • Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations • Utilized for environmental air-handling spaces (NEC 300.22)(C) • Allowable in assembly occupancies (NEC 518.4) • Permissible in theaters, audience areas of motion pictures, television studios, and similar locations (NEC 520.5) • Allowable installations in approved raceways and cable trays (NEC 392) • Suitable for installation under raised floors for IT equipment (NEC 645.5) • Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations • Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems
CONSTRUCTION:Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type XHHW-2 conductors rated 90°C dry locations. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked galvanized steel armor is applied over the entire assembly.
XHHW-2CopperConductors
SeparatorTape
InterlockedGalvanized SteelArmor
Listed E-301130
AWG/No. Type
Conductors
Green Ground Coil (ft) Reel (ft)
Standard PackagingOverall Diameter (in)
ApproximateNet Weight
(lbs/1000 ft) 90°C
Allowable Ampacity (Amps)*
75°C
Type MC-Copper Conductor Steel Armor/XHHW-2 Inners 600V
Note: Ampacities are based on Table 310.15(B)(16) of the NEC. *Ampacities shown are for general use as specified by the NEC, Section 310.15.For equipment marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C): 60°C when terminated to equipment for circuits rated 100 amperes or less or marked for size 14 AWG through 1 AWG conductor. 75°C when terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90°C for ampacity derating purposes.When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be reduced by a factor of 0.80 per NEC 310.15(B)(2)(a).The above data is approximate and subject to normal manufacturing tolerances.
14/214/314/412/212/312/410/210/310/48/28/38/46/26/36/44/34/43/33/42/32/4
StrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStranded
14 AWG14 AWG14 AWG12 AWG12 AWG12 AWG10 AWG10 AWG10 AWG10 AWG10 AWG10 AWG8 AWG8 AWG8 AWG8 AWG8 AWG6 AWG6 AWG6 AWG6 AWG
0.4640.4980.5360.5030.5420.5840.5530.5970.6460.6770.7570.8340.7910.8840.9740.9641.0701.0491.1641.1031.228
144169195176210245227275325359447534484610733803986969
119011231393
1515152020203030305555557575759595
115115130130
250'250'250'250'250'250'250'250'250'200'200'200'125'125'100'100'100'100'100'100'100'
1000'1000'1000'1000'1000'1000'1000'1000'1000'
500'/1000'500'/1000'500'/1000'500'/1000'500'/1000'500'/1000'
500'500'500'500'500'500'
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
SmartColorID®
AWG/No. Type
Conductors
Green Ground Coil (ft) Reel (ft)
Standard PackagingOverall Diameter (in)
ApproximateNet Weight
(lbs/1000 ft) 90°C
Allowable Ampacity (Amps)*
Number 277/480YNumber 120/208Y
75°C
Additional colors available subject to ERQ
234
Ground
Black/WhiteBlack/Red/White
Black/Red/Blue/WhiteGreen
22223344
Ground
Brown/GrayOrange/GrayYellow/GrayPurple/Gray
Brown/Yellow/GrayBrown/Orange/Gray
Brown/Orange/Yellow/GrayBrown/Yellow/Purple/Gray
Green
Standard Conductor Color Coding
See page 104 for complete legend
SmartColorID® Legend:
Features:Installation costs reduced up to 50% over conduit and wire. Insulating anti-short bushings are supplied with each reel or coil. SmartColorID® labels are spaced at regular intervals on the exterior of the metal sheathing and are removable. For ease of installation and pulling, cable is reverse wound on reels. Coils are designed to be pulled from the inside.
RemovableSmartColorID®
Label(patent pending)
1515152020203030305050506565658585
100100115115
SmartColorID®
800.962.9473 www.encorewire.com 53
TYPE MC-COPPER CONDUCTOR STEEL ARMOR/XHHW-2 INNERS
ENGINEERING SPECIFICATIONS:Standards:Underwriters Laboratories Standards UL-44, UL-1569 for type MC, Federal Specification A-A59544, IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test, and the National Electric Code (NEC); ARRA 2009; Section 1605 "Buy American" Compliant
Applications: Type MC cable shall be permitted as follows: • Permitted use for service power and feeder distribution in industrial, commercial, and multi-residential buildings • Acceptable for power, lighting, control, and signal circuits • Allowable in concealed or exposed systems • Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations • Utilized for environmental air-handling spaces (NEC 300.22)(C) • Allowable in assembly occupancies (NEC 518.4) • Permissible in theaters, audience areas of motion pictures, television studios, and similar locations (NEC 520.5) • Allowable installations in approved raceways and cable trays (NEC 392) • Suitable for installation under raised floors for IT equipment (NEC 645.5) • Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations • Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems
CONSTRUCTION:Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type XHHW-2 conductors rated 90°C dry locations. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked galvanized steel armor is applied over the entire assembly.
XHHW-2CopperConductors
SeparatorTape
InterlockedGalvanizedSteelArmor
Listed E-301130
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
ENCORE WIRE
RoHSCOMPLIANT
Conductors
AWG/No. 75°C 90°CStandard Packaging
(ft)
Allowable Ampacity (Amps)*
Type Ground
Approximate Net Weight
(lbs/1000 ft)
Outside DiameterOver Armor
(in)1/31/4
1/0-31/0-42/0-32/0-43/0-33/0-44/0-34/0-4250-3250-4300-3300-4350-3350-4400-3400-4500-3500-4600-3600-4750-3750-4
StrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStrandedStranded
6 AWG Green Insulated6 AWG Green Insulated
6 AWG Bare6 AWG Bare6 AWG Bare6 AWG Bare4 AWG Bare4 AWG Bare4 AWG Bare4 AWG Bare4 AWG Bare4 AWG Bare3 AWG Bare3 AWG Bare3 AWG Bare3 AWG Bare3 AWG Bare3 AWG Bare2 AWG Bare2 AWG Bare2 AWG Bare2 AWG Bare1 AWG Bare1 AWG Bare
1.1951.3361.2131.3351.3081.4411.4151.5621.5361.6971.6481.8221.7601.9481.8622.0611.9562.1672.1312.3632.4112.6772.6312.923
15201881174621852019253124783115296737553411433435794642450857634606599661177865721192948844
11431
130130150150175175200200230230255255285285310310335335380380420420475475
145145170170195195225225260260290290320320350350380380430430475475535535
1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels1000' reels
Type MC-Copper Conductor Steel Armor/XHHW-2 Inners 600V
Note: Ampacities are based on Table 310.15(B)(16) of the NEC. *Ampacities shown are for general use as specified by the NEC, Section 310.15.For equipment marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C): 60°C when terminated to equipment for circuits rated 100 amperes or less or marked for size 14 AWG through 1 AWG conductor. 75°C when terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90°C for ampacity derating purposes.When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be reduced by a factor of 0.80 per NEC 310.15(B)(2)(a).The above data is approximate and subject to normal manufacturing tolerances.
AWG/No. Type
Conductors
Green Ground Coil (ft) Reel (ft)
Standard PackagingOverall Diameter (in)
ApproximateNet Weight
(lbs/1000 ft) 90°C
Allowable Ampacity (Amps)*
Number 277/480YNumber 120/208Y
75°C
Additional colors available subject to ERQ
234
Ground
Black/WhiteBlack/Red/White
Black/Red/Blue/WhiteBare
22223344
Ground
Brown/GrayOrange/GrayYellow/GrayPurple/Gray
Brown/Yellow/GrayBrown/Orange/Gray
Brown/Orange/Yellow/GrayBrown/Yellow/Purple/Gray
Bare
Standard Conductor Color CodingFeatures:Installation costs reduced up to 50% over conduit and wire. Insulating anti-short bushings are supplied with each reel. For ease of installation and pulling, cable is reverse wound on reels.