PowerPoint OWN000204 BSC6800 Alarm Management
Upon completion of this course, you will be able to:
Master the management methods of alarm
Master the operation methods of alarm box
Master the operation methods of fault testing function
Internal Use
Chapter 3 Operation Methods of Alarm Box
Chapter 4 Operation Methods of Fault
Testing Function
Internal Use
Alarm Types
The alarms in the BSC6800 system can be divided into fault alarms
and event alarms:
Fault alarms triggered by hardware fault or abnormity of major
functions
Fault alarms can be divided into active or recovery alarms
Event alarms indicate some occasional events generated during the
running of the equipments
Event alarms represent an instantaneous state of the system that
may not be a fault
Event alarms cannot be divided into active or recovery alarms
Fault alarms have higher severity than event alarms
According to the state of the faults, fault alarms can also be
divided into active or recovery alarms:
If the fault is cleared, the state of the alarm will be “Recovery”,
and it is called a recovery alarm.
If the alarm is not cleared, the state of the alarm will remain to
be "Active”, and it is called an active alarm.
Internal Use
Alarm Severity
The BSC6800 has 4 alarm severity levels (listed in a descending
order):
Critical alarm
Reporting faults that affect the services, and need treatment
immediately
Major alarm
Reporting faults that affect the QoS, and need treatment in
time
Minor alarm
Reporting faults that are not serious enough to affect the QoS, but
need treatment at proper time
Warning alarm
Reporting faults that potentially threaten the system services, and
need treatment according to specific situations
Internal Use
Event Types
also be divided into 10 types:
Event Types
Correlative Alarms
Power system
Environment system
Alarms related to the equipment room environment, such as
temperature, humidity, and access control
Signaling system
Trunk system
Alarms related to the trunk system, including trunk circuits and
trunk boards
Hardware system
Alarms related to a board, such as clock and CPU
Software system
Communication system
Alarm related to the communication system, such as the one between
hosts and BAM servers
QoS
Internal Use
Chapter 3 Operation Methods of Alarm Box
Chapter 4 Operation Methods of Fault
Testing Function
Internal Use
Recovering Alarms
Filtering Alarms
Masking Alarms
Saving Alarms
Printing Alarms
Internal Use
Browsing Alarms
From the alarm browse window in LMT, operator can monitor the alarm
information in real time
In LMT, choose Alarm > Browse Alarm or click to display the
Alarm Browse window
Internal Use
Browsing Alarms
Double clicking alarm to browse the details of an alarm
Click MORE to browse alarm treatment suggestions.
Internal Use
Browsing Alarms
Managing Alarm Log
Alarm log is used to record details of alarms and can help operator
to learn the history operating situation of the system
Querying alarm log:
MML modeLST ALMLOG
GUI modeIn LMT, choose Alarm > Query Alarm Log or click
Internal Use
Managing Alarm Log
Setting alarm log
Alarm log is collected by and saved in BAM. Thus, operator need to
set the capacity and time limit of alarm logs in the BAM database
in case the logs may occupy too much storage of the hard disk
Setting log capacity and time limit SET ALMCAPACITY
Querying log capacity and time limit LST ALMCAPACITY
Internal Use
Recovering Alarms
When the fault is cleared or can be neglected, operator can
manually set the alarm to be recovery
Either MML or GUI mode can be used to recover alarm:
MML mode
RMV ALMFLT
GUI mode
In the fault alarm browse window, press Ctrl + Delete, or right
click the alarm and choose Manually Clear Alarm
Internal Use
Filtering Alarms
The alarm filter is used to filter specified alarms, for example,
alarms of a WFMRb DSP, or an E1/T1 port
The filtered alarms will not be sent to LMT or M2000
Creating an alarm filterCRE ALMFILTER
Activating an alarm filterRSM ALMFILTER
Suspending an alarm filterSPD ALMFILTER
Querying an alarm filterLST ALMFILTED
Operator can set alarm filters of different filtering requirements
on LMT. Only when the alarm filter is created and activated, it
will filter the alarms meeting the requirements. If it is
suspended, it will not filter any alarm.
Internal Use
Masking Alarms
The BSC6800 can mask derived alarms and has 4 mask levels: NOMASK,
LOW, MEDIUM and HIGH
HIGH: mask most of the derived alarms
MEDIUM: mask alarms not as many as HIGH, but more than LOW
LOW: mask only high-correlation derived alarms
NOMASK: the mask function is not in use
Setting alarm mask levelSET ALMML
Querying alarm mask levelLST ALMML
Internal Use
Saving Alarms
Operator can save part or all alarm information in the Alarm Browse
window or Query Alarm Log window
To save all alarms: right click and choose Save All Alarms
.
Setting Real time Print of Alarms:
After the setting, only the alarms that meet the requirements can
be printed
In LMT, choose Alarm > Alarm Realtime Print Set
Internal Use
Printing Alarms
Setting Manual Print of Alarms:
To print all alarms: right click and choose Print All Alarms
To print part of the alarms: choosing the alarms by <Ctrl> or
<Shift> keystroke, right click and choose Print Selected
Alarms
Internal Use
Chapter 3 Operation Methods of Alarm Box
Chapter 4 Operation Methods of Fault
Testing Function
Internal Use
Alarm Box Function
Fault alarms sent from BAM to LMT enable the alarm box to give
audible and visual indications
Alarm indicators of different colors represent different alarm
severity levels:
Red indicator: critical alarm
Orange indicator: major alarm
Yellow indicator: minor alarm
Connecting Alarm Box
1. Connect LMT with alarm box by a serial port cable
2. Choose Start > All Programs > HUAWEI Local Maintenance
Terminal > Convert Management System
3. Choose Operate > Configuration
4. Enter the external virtual IP address of the BAM, and choose the
COM port for the connection of LMT with alarm box
5. Click OK
In LMT, choose Alarm > Fault Alarm Sound
This task is to specify the severity levels for which the alarm box
sounds, as well as how long the alarm box sounds.
Internal Use
Stopping Alarm SoundSTP BOXSND
Resetting Alarm Indicator: CLR BOXLGT
Querying Alarm Indicator Status: LST BOXLGT
Resetting Alarm Box: RST ALMBOX
Setting Report to Alarm Box FlagSET BOXRPT
Setting Mask Level of Alarm BoxSET ALMSCRN
Querying Mask Level of Alarm BoxLST ALMSCRN
Querying Alarm Indicator StatusWhen LMT receives one or more fault
alarms of some severity level from BAM, the corresponding indicator
on the alarm box will flash. However, you cannot learn how many
alarms are happening just from the flashing indicator. This task is
to query the number of alarms that the flashing indicators
indicate.
Setting Report to Alarm Box FlagThis task is to set if an alarm
will be reported to alarm box.
Setting Mask Level of Alarm BoxThis task is to set the mask level
of alarm box. After the setting, the LMT will not send any fault
alarm below the level to the alarm box.
Internal Use
Chapter 3 Operation Methods of Alarm Box
Chapter 4 Operation Methods of Fault
Testing Function
Internal Use
Fault Testing Function
The function of system fault testing is to collect correlative
fault information for locating and clearing alarms
The BSC6800 provides the following fault tests:
Load Control Test
SAAL Test
Other Tests
1. Load Control Test: Testing load control of WMPU, Testing load
control of other boards in WRSS, Testing load control of WMUXb,
Testing load control of other boards in WRBS, Testing load control
of NodeB
2. E1 Test: Testing local E1 loopback, Testing remote E1 loopback,
Testing E1 BER
3. AAL2 PATH Test: Testing Iub AAL2 PATH, Testing Iu-CS AAL2
PATH
4. SAAL Test: Testing Iub SAAL link, Testing Iu SAAL link
5. Other Tests: Testing NodeB maintenance IPoA link, Testing Iu-PS
IPoA link, Testing internal multimachine communication, Testing
BCCH, Testing RFN, Testing clock
Internal Use
Creating Fault Testing Task
This slide uses “Load control test of other boards in WRBS” of
“Load control tests” to introduce how to create fault testing
task.
Internal Use
Querying Fault Testing Result
Operator can save fault testing result: right click Fault Test pane
and choose Save
Huawei Confidential. All Rights Reserved