PackagingMasterSealHLM5000SL,HLM5000S,andHLM5000R:5gal(18.95L)pails,55gal(208L) drums;availablespecialorder
MasterSealHLM5000T:5gal(18.95L)pailsMasterSeal995:300ftby371/2"(91by0.9m)rolls,yielding937ft2(87m2)
MasterSeal977:-50milby40"by48"(1.3mmby1mby1.2m)sheets,500perpallet,yielding1313ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.
-120mil(18")by40"by48"(3mmby1mby1.2m)sheets,500perpallet,yielding1313ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.
Liquid, cold-applied elastomeric waterproofing membrane systemFoRMeRLySonoSHieLdHLM5000
071400Fluid-applied Waterproofing7
PRODUcT HigHLigHTSAvailableinstandardandhigh-buildsystemsWaterproofingmembranetopreventwaterpenetration
elastomericaccommodatesexpansionandcontraction
Wideservice-temperaturerange,makingMasterSealHLM5000suitableforallclimates
Chemicalresistancetobacterialattack,selectacids,alkalisandsalts
Seamlesscold-appliedmembraneeliminateslapping,seamingandprecutting
doesnotrequirehot-meltequipment
aPPLicaTiOnSConcretePlywood(exterior)exteriorbelowgrade(onmasonry,concrete,andincidentalmetal)
Abovegrade(betweentwo-courseconcreteandwithincavitywalls)
ParkinggaragesandconcretetanksPlazadecksandmallsFountainsandpoolsBalconiesandplantersBelow-gradeslabsWallsandculvertsSeawalls,damsandreservoirs
MasterSeal HLM 5000
DeScRiPTiOnMasterSealHLM5000isaone-component,moisture-curing,bitumen-modifiedpolyurethaneelastomericwaterproofingmembraneforexteriorbelow-gradeorbetween-slabapplications.itisavailableinfourgrades:MasterSealHLM5000SL(self-leveling/squeegee) MasterSealHLM5000S(spray)MasterSealHLM5000T(trowel) MasterSealHLM5000R(roller)
YieLD 2530ft2/galat5565wetmils(0.610.74m2/Lat1.41.7mmwetthickness)
2530ft2/galat4555drymils(0.610.74m2/Lat1.11.4mmdrythickness)
Coveragemayvarywiththeapplicationtechniqueused.Actualcoveragerateandmilthicknessdependonfinishandporosityofthesubstrate.
STORage Storeinunopenedcontainersinclean,dryconditionsat40to80F(4to27C).duringstorage,aneasilyremovedskinofHLM5000mayform,whichdoesnotaffectperformanceoftheproduct.
SHeLF LiFe1yearPails6Monthsdrums
VOc cOnTenTMasterSealHLM5000SL:183g/LMasterSealHLM5000S:190g/LMasterSealHLM5000R:180g/LMasterSealHLM5000T:132g/L
HOW TO aPPLY MaSTeRSeaL HLM 5000SURFace PRePaRaTiOn
1.Forbestresults,allconcretedecksurfacesshouldbelightlysteeltroweledtoaflat,uniformsurface.Alightbroomfinishisacceptable.newconcretemustbeproperlywatercuredatleast14days.Membranecuringcompoundsmustbemechanicallyremoved.
Technical Data Guide
High-Build Standard System System
Hardness,Shoreoo n/A 85 ASTMC836
Viscosity, poise BrookfieldHLM5000SL 125HLM5000S 450HLM5000R 800HLM5000T 4,000
Tensile strength, psi(MPA) 200(1.4) 150(1.0) ASTMd412
average elongation, % 3001 600 ASTMd412
100% modulus,psi(Mpa) 80(0.6) 80(0.6) ASTMd412
Moisture-vapor permeability, 0.075 0.1 ASTMe96dryperms
crack bridging test, Passed1/4"; Passed116"; ASTMC836cycled10timesper nolossofbondor nolossofbond24hoursat15F(-9C) orcrackingexhibited orcrackingexhibited
extensibility after heat aging nocracking ASTMC836
adhesion in peel,lbs/in 5 ASTMC836(1lb/inminimum)
Weight loss, %(20%max) 16 ASTMC836
Resultsshownaretypicalbutarenotintendedasperformancecriteriaforon-siteinstalledmaterial.1Testedindirectionofgreatestelongationoffabric
elongation, % ASTM5034Machinedirection 54Crossdirection 147
grab breaking, lbs ASTM5034Machinedirection 54Crossdirection 32
Mullen burst,psi 70
Weight,lbs/ft250mil 0.188120mil 0.428
Burst strength,psi(MPa) 175 ASTMd2529
Puncture resistance,in-lbs 45 ASTMd781
Testresultsareaveragesobtainedunderlaboratoryconditions.Reasonablevariationscanbeexpected.
Test Data
PRoPeRTy VALue
PRoPeRTy VALue
Typical Properties
Minimum recovery,% 90
Swelling in water, nil3daysatroomtemperature
Service temp. range, F(C)Minimum -40(-40)Maximum 120(49)
Width,inMinimum 371/2Maximum 381/2
Length,ft 300
Thickness,in (FTM-5136)0.024(-0.0,+0.002)
nominal weight,oz/yd2 2.13
construction,in2 34by30
Yarn denier 70
PRoPeRTy ReSuLTS TeSTMeTHod
PRoPeRTy ReSuLTS TeSTMeTHod
PRoPeRTy ReSuLTS TeSTMeTHod
HLM5000
HLM5000(self-levelinggrade)
MasterSeal995
MasterSeal977
MASTeRSeAL995
Technical Data compositionMasterSealHLM5000isabitumen-modifiedpolyurethane.
compliancesASTMC836nationalstandardofCanada37.58-M86developedbyCGSB
TechnicaldataGuideMasterSeal HLM 5000
VenT,dRAinPiPe,AndPoSTPeneTRATionSCleanmetalsurfacestobrightmetalandprimewithaqualityrust-inhibitingmetalprimerfollowedbyMasterSealP173orP176.Removedust,debrisandanyothercontaminantsfromvoids.Sealwiththeappropriatesealant.
aPPLicaTiOnAtestapplicationisalwaysrecommendedbeforeproceedingwithentireapplication.noTe:Finishcoatmustbeappliedinapinhole-free,continuousmembraneforwaterproofingintegrity.
STAndARdSySTeM1.SelectthegradeofMasterSealHLM5000thatbestmeetsindividualjobrequirements.useMasterSealHLM5000Tfortrowelapplication,MasterSealHLM5000Sforsprayapplication,MasterSealHLM5000RforrollerapplicationorMasterSealHLM5000SLforsqueegeeapplication.
2.Forhorizontalapplications,emptycontentsofpailandspreadimmediatelytoensureworkability.Bestresultsareobtainedbymarkingoff125ft2(11.61m2)areasandevenlyspreadingthecontentsofa5gallon(18.93L)unitwitharubber-edgednotchedsqueegee.Repeattheaboveprocedureuntiltheentiresurfaceiscovered.
3. Forverticalapplications,applybytrowel,rollerorsprayattherateof25ft2/gallon(0.6m2/L).Bestresultsareobtainedbymarkingoff125ft2
(11.6m2/L)andevenlyapplyingthecontentsofa5gallon(18.93L)pail.
4.Verifytheappliedthicknesswithawetmilgaugeastheworkprogresses.
5.Theintegrityofthecuredmembraneonahorizontalsurfacemaybeverifiedbydammingtheentireareaandfloodingwithwatertoaminimumdepthof2"(51mm)andallowingthewatertostandfor2448hours.Visuallyinspectthebottomsurfacetocheckforanywaterpenetration.ifrepairsarenecessary,theareashouldbedrainedandallowedtodrybeforereapplyingMasterSealHLM5000.Afterreapplication,theareashouldbetestedagainformembraneintegrity.
HiGH-BuiLdSySTeMConcreteapplication:Apply60wetmilsofMasterSealHLM5000,followedbysettingMasterSeal995reinforcingfabricintothewetmaterial.overlapallseamsaminimumof3"(76mm).Additionalmaterialmayberequiredtoproperlyembedthereinforcingfabricwhereitoverlaps.Allowthefirstcoattocureovernightandfollowwithasecond60wet-milapplicationofMasterSealHLM5000.
Plywoodapplication:AllplywoodconstructionmustcomplywithAPA(AmericanPlywoodAssociation)standards.CaulkalljointswithaMasterBuildersSolutionssealantandthenproceedwiththeMasterSealHLM5000high-buildsystem.
SPRAyequiPMenTForsprayequipmentrecommendations,consulttheequipmentmanufacturer.
cURingAppreciablepropertiesdevelopwithin2448hoursat75F(24C)and50%relativehumidity.ProtectMasterSealHLM5000fromtrafficduringcuring.
DRainage anD PROTecTiOn1.Forprotectionduringbackfillandwherehydrostaticpressureisanticipated,usetheappropriateMasterSeal975drainBoardSystemforinstallationinstructions.
2. Forprotectionduringbackfillonly,installprotectionboardassoonaspossiblefollowingcureofMasterSealHLM5000.
cLean UPCleanalltoolsandequipmentimmediatelyafterapplicationwithMasterSeal990.
HOW TO aPPLY MaSTeRSeaL 977SURFace PRePaRaTiOn
1.Waterproofingmembranesmustbeprotectedagainsttear,puncture,andotherabusesduringplacementofconcretewearingslabsandreinforcingsteel.Theyshouldalsobeprotectedfromjobsitetrafficandbackfillingoperations.
2.Allspecificationscallingformembranewaterproofingshouldalsorequireprotectionofmembraneasanintegralpartoftheoverallwaterproofingsystem.
2.Forextremelyporousblock:PrimewithacoatofMasterSealHLM5000dilutedupto25%withMasterSeal990orxylene.orapplyapargecoatofMasterSeal581attherateofapproximately400ft2(37.2m2)perbagandallowtocureaminimumof7daysbeforeapplyingMasterSealHLM5000.
3.Removedust,dirtandothercontaminantsjustbeforeorduringapplication.Surfacesmustbedryatthetimeofapplication.
4.Air-voidpockmarksorhoneycombsmustbeopeneduptoallowMasterSealHLM5000tofillthecavitiescompletely.Airentrapmentwithinvoidsmaycauseblisters.extremecasesmayrequireadditionalrepair.
PReSTRiPing1.Beforeapplyingthefinalmembrane,alljoints,cracksandopeningsaroundprotrusionsmustbesealedbycaulkingorprestriping(apreliminarycoatingofMasterSealHLM5000appliedwithatrowelorstiff-bristledbrush).Allowtodryovernightbeforeapplyingfinalmembrane.
2.Whenthefinalmembraneisapplied,theoverallthicknessoverjointsandcracks,atcovesandaroundpenetrationsshouldbeapproximately100wetmils(2.5mm)onthestandardsystem.
STATiCJoinTSAndCRACkSJointsandcrackslessthan116"
(1.6mm)should
befilledbyprestriping.Applymaterialsoitbothfillsandoverlapsthejointorcracktoawidthof4"(102mm)oneachside.
WoRkinGoRexPAnSionJoinTSAlljointsover18"(3mm)mustbesealedwithaMasterBuildersSolutionsurethanesealant.Anyworkingjointlessthan18"(3mm)shouldberoutedtoaminimumof1/4"(6mm)andfilledwithasealant.Preventthewaterproofingmembranefromadheringtothejointsealant,whichcouldcausesealantormembranefailure,byapplyingacoatofwaxorbondbreakertapeoverthecuredsealantandthenprestriping.
unCoATedMeTALSuRFACeSRemovedust,debris,andanyothercontaminantsfromvent,drainpipeandpostpenetrations,regletsandothermetalsurfaces.CleansurfacestonearwhiteperSSPC-nACe2andprimeimmediatelywithMasterSealP173.ProvideappropriatecantwithMasterSealnP1
ornP2sealantstoeliminate90angles.
aPPLicaTiOninstalloverlappingMasterSeal977protectionboardassoonaspossiblefollowingcureoftheliquidmembrane.ProtectMasterSealHLM5000fromtrafficbeforeplacementofprotectionboard.MasterSealHLM5000mustbecuredbeforeinstallationofanytopping.
FOR BeST PeRFORManceMASTeRSeALHLM5000
ApplyMasterSealHLM5000whensubstratesaredryandairtemperaturesare40to90F(4to32C);forapplicationattemperaturesbelow40F(4C),consultTechnicalServices.
TemperaturesinfluenceviscosityandhandlingcharacteristicsofMasterSealHLM5000:heatincreasesandcolddecreasestheflow.keepMasterSealHLM5000coolinhotweatherandwarmincoldweather.
Avoidapplicationwheninclementweatherispresentorimminent.
donotapplytoreinforcingbarsortowetorcontaminatedsurfaces.
donotdirectlyheatcontainerswithflame,stove,hotplateoroven.
PatchallvoidsanddeepdepressionsinsubstrateswithappropriatepatchingmaterialbeforeapplyingMasterSealHLM5000.
useMasterSeal550underthin-settileapplications.BeforeapplyingMasterSealHLM5000,damalldrainsanddrainopenings.
Carefullyworkmaterialoverirregularconcretetoavoidpinholesandholidays.
ProtectMasterSealHLM5000coatedsurfacesfrompuncturewithprotectionboarduntilrequiredtoppingorbackfillisplaced.
notintendedasanexposedorwearingsurface.donotusewhereasolventodorisobjectionable,e.g.,nearareaswherefoodpreparationorprocessingoccurduringtheapplication.
SpecifywetorpapercuringforconcretetobecoatedwithMasterSealHLM5000;avoidusingliquidcuringcompounds.
inhorizontalapplicationsconcretemustbesloppedtodraintoavoidpondingwateronthesurfaceofMasterSealHLM5000
WhenusingdrainagematdirectlyoverMasterSealHLM5000,alayerof6milpolyethylenesheetingshouldbeusedbetweentheMasterSealHLM5000andthedrainagemat.
MASTeRSeAL977StoreMasterSeal977onaflatsurfaceandkeepitdry;donotremoveshrinkwrapuntilimmediatelybeforeuse.
ifboardisexposedtoprolongedperiodsofwaterimmersionorexcessivehumidity,itmaycurlorwrinkle.
MasterSeal977tobecoveredwithaconcretewearingcoursemustbesecurelyattachedtomembrane.
GeneRALProperapplicationistheresponsibilityoftheuser.FieldvisitsbyBASFpersonnelareforthepurposeofmakingtechnicalrecommendationsonlyandnotforsupervisingorprovidingqualitycontrolonthejobsite.
HeaLTH, SaFeTY anD enViROnMenTaLRead,understandandfollowallSafetydataSheetsandproductlabelinformationforthisproductpriortouse.
LiMiTeD WaRRanTY nOTice BASFwarrantsthisproducttobefreefrommanufacturingdefectsandtomeetthetechnicalpropertiesonthecurrentTechnicaldataGuide,ifusedasdirectedwithinshelflife.Satisfactoryresultsdependnotonlyonqualityproductsbutalsouponmanyfactorsbeyondourcontrol.BASFMAkeSnooTHeRWARRAnTyoRGuARAnTee,exPReSSoRiMPLied,inCLudinGWARRAnTieSoFMeRCHAnTABiLiTyoRFiTneSSFoRAPARTiCuLARPuRPoSeWiTHReSPeCTToiTSPRoduCTS.ThesoleandexclusiveremedyofPurchaserforanyclaimconcerningthisproduct,includingbutnotlimitedto,claimsallegingbreachofwarranty,negligence,strictliabilityorotherwise,isthereplacementofproductorrefundofthepurchaseprice,atthesoleoptionofBASF.Anyclaimsconcerningthisproductmustbereceivedinwritingwithinone(1)yearfromthedateofshipmentandanyclaimsnotpresentedwithinthatperiodarewaivedbyPurchaser.BASFWiLLnoTBeReSPonSiBLeFoRAnySPeCiAL,inCidenTAL,ConSequenTiAL(inCLudinGLoSTPRoFiTS)oRPuniTiVedAMAGeSoFAnykind.
Purchasermustdeterminethesuitabilityoftheproductsfortheintendeduseandassumesallrisksandliabilitiesinconnectiontherewith.ThisinformationandallfurthertechnicaladvicearebasedonBASFspresentknowledgeandexperience.However,BASFassumesnoliabilityforprovidingsuchinformationandadviceincludingtheextenttowhichsuchinformationandadvicemayrelatetoexistingthirdpartyintellectualpropertyrights,especiallypatentrights,norshallanylegalrelationshipbecreatedbyorarisefromtheprovisionofsuchinformationandadvice.BASFreservestherighttomakeanychangesaccordingtotechnologicalprogressorfurtherdevelopments.ThePurchaseroftheProduct(s)musttesttheproduct(s)forsuitabilityfortheintendedapplicationandpurposebeforeproceedingwithafullapplicationoftheproduct(s).Performanceoftheproductdescribedhereinshouldbeverifiedbytestingandcarriedoutbyqualifiedexperts.
TechnicaldataGuideMasterSeal HLM 5000
Dynamic crack Detail
asphalt Pavement Topping/expansion Joint
Vent/Drain/Pipe/Post Penetration Detail
Split Slab with cant DetailWaterproofing at Bi-Level Drain
inside corner Detail (Static)
Waterproofing Foundation Walls
expansion Joint Detail
Static crack/Prestripe Detail
= Registered Trademark of BASF Group in many countries of the world
BASF Chemicals & Polymers Pakistan (Pvt) Ltd. Construction Chemicals Division 46-A,Block-6, P.E.C.H.S., Shahrah-e-Faisal, Karachi-75400
email: [email protected]
Karachi Tel: 021 111 550 550 Lahore Tel: 042 111 550 550 Islamabad Tel: 051 4446106-08
Website: www.master-builders-solutions.basf.pk
TechnicaldataGuideMasterSeal HLM 5000