Transcript
Page 1: 3155 West 33rd Street RLM Angled Reflector www ...rhlightingsolutions.com/downloads/spec_sheets/RHLS_angle_reflector.pdf · rlm angle reflectors − dimensions and technical data

MADE IN USA u © 2010 RH Lighting Solutions u3155 West 33rd Street, Cleveland, OH 44109

www.rhlightingsolutions.com u Phone: 877-905-4448 (877-90-LIGHT) u Fax: 877-428-3080

Page

7

RLM Angled Reflector

Fixture

Number

Fixture

ColorMounting

Mounting

Color

Optional

AccessoriesGuard Color

Wattage and

Lamp Options

Ballast Options

and Voltage

ANR10

ANR12

ANR14

Standard(1)

Colors

A (White)

B (Black)

C (Copper)

D (Dk. Green)

E (Lt. Green)

F (Blue)

G (Bronze)

H (Silver)

I (Red)

J (Yellow)

K (Orange)

L (Brown)

Specialty

Finishes

GS (Galv. Steel)

PC (Pure Copper)

PB (Pure Brass)

Z (Custom)

LD96 (Prewired With 96˜

Leads and ¾ Hub

Cord Mount Options(2)

CW310 (Prewired With 10’3/C White Cord.)

CB310 (Prewired With 10’3/C Black Cord.)

CW510 (Prewired With 10’5/C White Cord.)

CB510 (Prewired With 10’5/C Black Cord.)

RCC Canopy For Cord

Stem Mount Options

ST5012, ST5024, ST7512, ST7524,

STM __ (Custom: Specify Length

& Thread ¾˜ or ½˜ Npt.)

RCR (Rigid Mount Canopy.)

RCA (Aligner Mount Canopy

Gooseneck Style Bracket Arms

WMG10, WMG18, WMG22, WMG23,

WMG24, WMG25, WMG30, WMG32,

WMG37, WMG40, WMG48, WMG56

WCS (Optional Gooseneck

Bracket Canopy.)

WCD (Decorative Gooseneck

Bracket Canopy.)

Pole Top and Wall Bracket Arms

PM1, PM2, PM3, PM4, PM12, PM22,

PM32, PM42, PM5, WB1, WB2, WB22

WB1B, WB2B (Optional Wall Box

For WB1, WB2 or WB22 Bracket.

Standard

Colors

A (White)

B (Black)

C (Copper)

D (Dk. Green)

E (Lt. Green)

F (Blue)

G (Bronze)

H (Silver)

I (Red)

J (Yellow)

K (Orange)

L (Brown)

Z (Custom)

Glass

Globe

41C

Sm. Clear

41P

Sm. Prism.

42C

Lg. Clear

42P

Lg. Prism.

Cast Guard

for Globe

31CG

32CG

Wire

Guards

RWG8

RWG10

RWG12

RWG14

Do not specify

Color for

Standard Finish

(Cast Guard is

Raw Aluminum

Wire Guard is

Bright Zinc.)

Color Options

A (White)

B (Black)

C (Copper)

D (Dk. Green)

E (Lt. Green)

F .(Blue)

G (Bronze)

H (Silver)

I (Red)

J (Yellow)

K (Orange)

L (Brown

Z (Custom)

MED−120

(E26 Base 150W Max 120V

INC, CFL or LED Lamps.)

GU24−120

(GU24 Base 120V for CFL)

Compact(3)

Fluorescent

13CF (G24Q−1/GX24Q−1)

18CF (G24Q−2/GX24Q−2)

26CF (GX24Q−3)

32CF (GX24Q−3)

42CF (GX24Q−4)

57CF (GX24Q−5)

DMPL Powerline Dimming

Option (2 Wire)

DMCW Control Wire

Dimming Option

Pulse Start(3)

Metal Halide

50PSMH (E26 Base)

70PSMH (E26 Base)

100PSMH (E26 Base)

150PSMH (E26 Base)

High Pressure(3)

Sodium

50HS (E26 Base)

70HS (E26 Base)

100HS (E26 Base)

150HS (E26 Base)

Ballast Option

Not Required

for MED−120 or

GU24−120

BCW

(Canopy Ballast,

Wall Mounted,

Multi Voltage

120−277)

BCS

(Canopy Ballast,

Stem Mounted,

Multi Voltage

120−277)

BCC (2)

(Canopy Ballast,

Cord Mounted,

Multi Voltage

120−277)

RB

(Remote Mount

Ballast Multi

Voltage 120−277)

PLB−120(4)

(Post Line

Ballast 120V)

PLB−277(4)

(Post Line

Ballast 277V)

Order Example − Select Items from Above Columns to Build Catalog Number

ANR10 D WMG23 B 41P−31CG B 70PSMH RB

Notes: (1) For color specifications refer to color chart on page 33.

(2) Cord mount units for remote CFL Ballast requires 5/C cord set option CW510 or CWB510.

(3) CFL and HID Units require globe option. Maximum wattages for 41 series small globes are 100W INCandescent, 32W CFL and 100W HID.

Maximum wattages for 42 series large globes are 150W INC. 57W CFL and 150W HID. See page 41 for complete globe options.

(4) Postline Ballast for Metal Halide requires minimum 4˜ diameter pole. PLB for HPS requires minimum 3˜ diameter pole.

Job Name:

Type: Quantity:

Catalog No:

Notes:

RH Lighting Solutions

3155 West 33rd Street

Cleveland, OH 44109

Phone: 877−905−4448

Fax: 877−428−3080

www.rhlightingsolutions.com

APPLICATION − Effective signage illumination is the primary objective of

the Angled Reflector. While definitely a nostalgic luminaire, combining

it with today’s lamp sources provides the lighting designer with a major

tool for addressing both illumination levels and energy requirements.

FINISH − 90%+ reflective white polyester powder coat is standard

inside and out. For color options see chart on page 33.

REFLECTOR − Heavy wall, computer controlled, precision spun aluminum.

Galvanized steel, copper or brass specialty materials are available.

Turned−down bead adds strength and prevents the collection of dirt.

LAMP OPTIONS − Medium base incandescent or HID lamps up to 150

watts(2). Compact fluorescent lamps up to 57 watts (2).

SOCKET − Medium (E26) base glazed porcelain rated for 660 watts, 600

Volts. 4Kv Pulse rated. CFL Units with thermolastic sockets for 4−pin

plug−in lamps or GU24 base lamps.

MOUNTING − Units mount from a heavy die−cast flange with left hand

thread locking nut. Flange tapped with a 3/4−14 NPT thread. Units

prewired with 96" leads for pipe or bracket mount or with 10’ white or

black cord for use with canopy kit.

LISTING − ETL Listed for Wet Locations. Cord

mount units listed for damp locations only.

13 − 150 watts

PSMH | HPS | CFL | INC

Page 2: 3155 West 33rd Street RLM Angled Reflector www ...rhlightingsolutions.com/downloads/spec_sheets/RHLS_angle_reflector.pdf · rlm angle reflectors − dimensions and technical data

MADE IN USA u © 2010 RH Lighting Solutions u3155 West 33rd Street, Cleveland, OH 44109

www.rhlightingsolutions.com u Phone: 877-905-4448 (877-90-LIGHT) u Fax: 877-428-3080

Page

8

Floodlight Type Photometric Characteristics

IES NEMA Type 7 H x 5 V

Maximum Candela 539

Maximum Candela Angle 0°H 25°V

Horizontal Beam Angle (50%) 96.6

Vertical Beam Angle (50%) 96.6

Horizontal Field Angle (10%) 145.6

Vertical Field Angle (10%) 92.7

Total Rated Lamp Lumens 1750

Beam Lumens 858.39

Beam Efficiency 49.05%

Field Lumens 1151.94

Field Efficiency 65.82%

Spill Lumens 33.64

Total Lumens 1185.57

Total Efficiency 67.75%

RLM ANGLE REFLECTORS − DIMENSIONS AND TECHNICAL DATA

PHOTOMETRIC DATA

ANR12−100INC − 1750 Lumen A19 Frosted Lamp

ISOCANDELA CURVESSIGN LIGHTING APPLICATION: ISOFOOTCANDLE LINES OF

ILLUMINATION, DISTANCE IN UNITS OF SETBACK DISTANCE.

VALUES BASED ON 4’ SETBACK.

ANR14ANR12ANR10


Recommended