Upload
balan-balan
View
1.204
Download
114
Embed Size (px)
DESCRIPTION
Alarm Description
Citation preview
Row Labels Alarm description1588 clock link fault(198092240) No1588 clock source unavailable(198092241) NoAbnormal battery of built-in power(198092458) External Alarm -DependAbnormal power(198092278) External Alarm -DependAbnormal temperature at air intake(198092042) External Alarm -DependApplication software monitoring alarm(198096403) NoATMA communication link is interrupted(198092334) NoBaseband data link error alarm(198092612) NoBATERY UNDER VOLTAGE(198092555) External Alarm -DependBoard communication link is interrupted(198092010) Service Affected AlarmBoard configuration parameter error(198093922) Service Affected AlarmBoard initialization(198092348) Service Affected AlarmBoard not-in-position(198092072) NoBoard reboots(198096404) Service Affected AlarmCalibrate Fail(198092364) NoDevice temperature is high(198096400) External Alarm -DependDisable PA(198092245) Service Affected AlarmE1/T1 input port unavailable(198092011) Service Affected AlarmE1/T1 output port unavailable(198092012) Service Affected AlarmEmbedded power AC Power Off(198092074) External Alarm -DependEmbedded power Bat Discharge(198092104) External Alarm -DependEmbedded power Door Magnet Alarm(198092113) External Alarm -DependEmbedded power Environment is over-temperature(198092106) External Alarm -DependEmbedded power Rectifier Module Fault(198092117) External Alarm -DependEnvironmental temperature is high(198096401) External Alarm -DependES or SES detected on the E1 link in the past 15 minutes has exceeded the threshold(198092013) Service Affected AlarmEthernet access network interface abnormal(198092009) noHardware alarm(198093818) Service Affected AlarmHDLC Link is broken(198092232) Service Affected AlarmHigh AC phase current of built-in power(198092448) External Alarm -DependHIGH TEMP(198092558) External Alarm -DependINTRUDER ALARM(198092550) External Alarm -DependIPTB Setup Link Failed(198092603) Service Affected AlarmLine clock has the fault(198092309) NoLink Broken Between OMM and NE(198099803) Service Affected AlarmLMT accessing(198092060) NoLost of synchronization(198092215) Service Affected AlarmNode B reboot(198096405) Service Affected AlarmPPP Link is broken(198092231) Service Affected AlarmRECTIFIER FAILURE(198092554) External Alarm -DependRemote antenna over VSWR alarm(198092257) Service Affected AlarmRemote antenna VSWR alarm(198092283) Service Affected AlarmRemote output power abnormal voltage alarm(198092254) Service Affected AlarmRequire Radio Param timeout for times(198092604) NoRET communication link is interrupted(198092342) NoRET don't calibrated(198092343) NoRET motor can't adjust(198092340) NoRF board PLL alarm(198092249) Service Affected AlarmRRU network interrupted alarm(198092433) Service Affected AlarmRRU power-cut alarm(198092295) Service Affected AlarmRRU radio frequency group unavailable(198092437) Service Affected AlarmRTWP abnormal(198093864) Service Affected AlarmSCTP association is interrupted(198092230) Service Affected AlarmSNTP time adjustment failure alarm(198092014) NoSYSTEM MAIN FAILURE(198092551) External Alarm -DependThe channel downlink frame is unlocked(198092287) NoThe frame transferred over Rx port of RRU is unlocked(198092294) NoThe optical/electric module is not in position(198092289) Service Affected AlarmThe strength of received optical signal is abnormal(198092431) Service Affected AlarmThe uplink frame at optical/electric port is unlocked(198092286) Service Affected AlarmThe uplink optical/electric link is interrupted(198092290) Service Affected AlarmTNB FAILURE(198092566) External Alarm -DependUser face Emac Interface Error(198092617) Service Affected AlarmVoltage of DC input is abnormal(198092053) External Alarm -Depend
Alarm description (Sector) SystemNONO
DepandDepandDepand
Sector Alarm NOSector Alarm NO
NODepand
Sector Alarm YESYES
Sector Alarm YESNO
Sector Alarm YESNO
DepandSector Alarm YES
YESYES
DepandDepandDepandDepandDepandDepand
YESNOYESYES
DepandDepandDepand
YESNOYESNO
YES YESYESYES
DepandSector Alarm YESSector Alarm YES
YESNO
Sector Alarm NOSector Alarm NOSector Alarm NOSector Alarm YESSector Alarm YES
YESSector Alarm YESSector Alarm YES
YESNO
DepandNO
Sector Alarm NOYESYESYESYES
DepandYES
Depand
Location
Ground Resource Management(SDRII)=1,Rack(SDRII)=1,Shelf(SDRII)=1,Board(SDRII)=13 apply to all systemGround Resource Management(SDRII)=1,Rack(SDRII)=2,Shelf(SDRII)=1,Board(SDRII)=1 GSM 900 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=3,Shelf(SDRII)=1,Board(SDRII)=1 GSM 900 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=4,Shelf(SDRII)=1,Board(SDRII)=1 GSM 900 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=51,Shelf(SDRII)=1,Board(SDRII)=1 GSM 1800 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=52,Shelf(SDRII)=1,Board(SDRII)=1 GSM 1800 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=53,Shelf(SDRII)=1,Board(SDRII)=1 GSM 1800 Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=57,Shelf(SDRII)=1,Board(SDRII)=1 3G Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=58,Shelf(SDRII)=1,Board(SDRII)=1 3G Per SectorGround Resource Management(SDRII)=1,Rack(SDRII)=59,Shelf(SDRII)=1,Board(SDRII)=1 3G Per Sector