Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
ISOLATION PRODUCTS
DOC NO: YU-br-iso-instr-1005-1
YUTECH INSTRUMENTS
IN
Transient Surge havingt < reaction time can reachupto 2000 Volts and candamageyour Circuitry
Actual Signal
Electric Noise Superimposedover Actual Signal
Isolated Output Signal
Isolated Power SupplyIsolated Power Supply
2500Vrms Isolation Barrier
Isolated Input andOutput Ground
Internal Power Supply Grounding isElectrically Isolated from theMain Power Supply
Signal Isolators / Isolation Barriers
Isolate and Protect your Automation System
from
all Electrical Problems
[email protected]; [email protected] www.yutech.inI
PRODUCT CODE:A-ISO-AC-C1-C2-SA-ISO-DC-C1-C2-S 1 2
PS
IPS-I
IPS-II
IN
35
6
IPS-II
4
7
8
4-20mAIN
ISOLATED4-20mAOUTPUT 1
ISOLATED4-20mAOUTPUT 2
PLC / DCS Panel
Controller I/O
ANALOGOUTPUTCARDCH #
VFD Panel
PLC / DCS IO CARD
PRODUCT CODE:A-ISO-AC-C1-C2-S
1 2PS
IPS-I
IPS-II
IN
35
6
IPS-II
4
7
8
4-20mAIN
ISOLATED4-20mAOUTPUT 1
ISOLATED4-20mAOUTPUT 2
VFD
ANALOGINPUTEXTERNALSPEEDREFERANCE
External Speed RefDisplayed as Percentage
in VFD Panel
ACI
HT / LT PANEL
HT / LTCONDUCTOR
LT / HT CT
IN3
4
9
10
1 2
PS
IPS-I
IPS-II
IPS-IIISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-HTCT-C1-MA-ISO-DC-HTCT-C1-MA-ISO-AC-LTCT-C1-MA-ISO-DC-LTCT-C1-M
CT SECONDARYCURRENT AS INPUT0-1A AC FOR HTCT0-5A AC FOR LTCT
TWISTEDPAIRSHIELDEDARMOUREDCABLE
TERMINATIONIN PANEL AND INCONTROLLERPLC / DCS IO CARDS
JB / AUTOMATIONPANEL
IN3
4
9
10
1 2
PS
IPS-I
IPS-II
IPS-IIISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-HTCT-C1-MA-ISO-DC-HTCT-C1-MA-ISO-AC-LTCT-C1-MA-ISO-DC-LTCT-C1-M
CT SECONDARYCURRENT AS INPUT0-1A AC FOR HTCT0-5A AC FOR LTCT
SCHEMATIC AND APPLICATION DIAGRAM: DC Current Isolator - Single Input Dual Outputs (Repeats the Input over Two Output Channels) VDC / VAC PS
SCHEMATIC AND APPLICATION DIAGRAM: Isolating LT / HT CT Converter, 0-5A AC Input, 4-20mA Output, VDC / VAC PS
SCHEMATIC AND APPLICATION DIAGRAM: Isolating AC Signal Converter – Frequency (0-10KHz @ 5VPP), to Current (4 – 20 mA), VDC / VAC PS
ISOLATION PRODUCTS
DOC NO: YU-br-iso-instr-1005-1
ACV
FIELD SIDE
YUTECH RPMSENSOR
TOOTH-WHEEL FITTEDON SHAFT OF THEROTOR / DEVICEWHOSE SPEED ISTO BE MEASURED
Controller I/O
ANALOGINPUTCH #
IN
0-10 KHZ5V-PPINPUT
POWERSUPPLY
ISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-F-C1-SA-ISO-DC-F-C1-S
1 2
3
4
5
6
IN
0-10 KHZ5V-PPINPUT
POWERSUPPLY
ISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-F-C1-MA-ISO-DC-F-C1-M
1 2
3
4
9
10
[email protected]; [email protected] www.yutech.inI
IN
ISOLATEDCOLD JUNCTIONCOMPENSATED4-20mAOUTPUT
POWERSUPPLY
1 2
3
4
5
PRODUCT CODE:A-ISO-DC-TC#-C1-SA-ISO-AC-TC#-C1-S
TC INPUTJ / K / B / S / RTYPE
6
IN
ISOLATEDLINEARIZED4-20mAOUTPUT
POWERSUPPLY
1 2
3
4
6
7
PRODUCT CODE:A-ISO-DC-RT-C1-SA-ISO-AC-RT-C1-S
2 / 3 WIRERTD PT-100INPUT
8
IN
ISOLATEDLINEARIZED4-20mAOUTPUT
POWERSUPPLY
1 2
3
4
5
7
PRODUCT CODE:A-ISO-DC-RT4W-C1-SA-ISO-AC-RT4W-C1-S
4 WIRERTDPT-100INPUT
8
6
IN
ISOLATEDLINEARIZED4-20mAOUTPUT
POWERSUPPLY
1 2
3
4
5
7
PRODUCT CODE:A-ISO-DC-RT4W-C1-SA-ISO-AC-RT4W-C1-S
4 WIRERTDPT-100INPUT
8
6
SCHEMATIC AND APPLICATION DIAGRAM: Isolating Temperature Transmitters - Input: 2/3W RTD PT-100, 4W RTD PT-100, 4W RTD PT-1000, TC, Output: 4-20mA
SCHEMATIC AND APPLICATION DIAGRAM: DC Current Isolator - Dual Channel (Two independent Input and Output Channels) VDC PS (2 Wire Output)
FT
Flow Meter
Field SidePowerSupply
TransmitterANALOG INPUT CARD
ANALOGINPUTCH #
ControllerSide PowerSupply
Field Controller Panel
MainsPowerSupply
24VDC
IN4-20mACH-1
IN4-20mACH-2
1
2
3
4
5
6
7
8
PRODUCT CODE:A-ISO-DC-C2-C2-S
ISOLATED4-20mA ON 2W TXOUT CH-1
ISOLATED4-20mA ON 2W TXOUT CH-2
ANALOGINPUTCH ##
IN4-20mACH-1
ISOLATED4-20mA ON 2W TXOUT CH-1
IN4-20mACH-2
5
6
7
8
PRODUCT CODE:A-ISO-DC-C2-C2-S
ISOLATED4-20mA ON 2W TXOUT CH-2
IN
POWERSUPPLY
AUXILIARYPOWERSUPPLY5VDC
EXTERNALPOTENTIO-METER
ISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-R1-C1-SA-ISO-DC-R1-C1-S
1 2
3
45 7
6
8
1 2
PS
IN4-20mAIN
3
4
5
6
PRODUCT CODE:A-ISO-AC-C1-C1-S
ISOLATED4-20mAOUTPUT
PLC / DCS Panel
VFD
ANALOGINPUTEXTERNALSPEEDREFERANCE
Controller I/O
ANALOGOUTPUTCARDCH #
VFD Panel
PLC / DCS IO CARD
DOUBLEPOLERELAY
Auto / ManualSwitch
C
NO
NC
COIL
REMOTE LOCATION
TWISTEDPAIRSHIELDEDARMOUREDCABLE
COIL EXCITATIONVOLTAGE (230VAC)
IN
POWERSUPPLY
AUXILIARYPOWERSUPPLY5VDC
POTENTIO-METRIC IN
ISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-R1-C1-SA-ISO-DC-R1-C1-S
1 2
3
45 7
6
8POTEND H
WIPER
POTEND L
1 2
PS
IN4-20mAIN
3
4
5
6
PRODUCT CODE:A-ISO-AC-C1-C1-SA-ISO-DC-C1-C1-S
ISOLATED4-20mAOUTPUT
SCHEMATIC AND APPLICATION DIAGRAM: DC Current Isolator and Isolating Resistance to Current Converter
ACV
FIELD SIDE
AC TACHOGENERATOR
IN3
4
9
10
1 2
PS
IPS-I
IPS-II
IPS-IIISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-AVH-C1-MA-ISO-DC-AVH-C1-M
0-100 VACINPUT
Controller I/O
ANALOGINPUTCH #
AUTOMATION PANEL
IN3
4
9
10
1 2
PS
IPS-I
IPS-II
IPS-IIISOLATED4-20mAOUTPUT
PRODUCT CODE:A-ISO-AC-AVH-C1-MA-ISO-DC-AVH-C1-M
0-100 VACINPUT
SCHEMATIC AND APPLICATION DIAGRAM: Isolating AC Signal Converter – High AC Voltage (0-100VAC) to standard DC Current (4 – 20 mA),VDC / VAC PS
ISOLATION PRODUCTS
Y G S . L .U TECHNOLO IE PVT TDHead Office & Works: B 8/5, Opposite Power Substation, MIDC, Miraj 416410, Dt. Sangli, Maharashtra, India.
+91 264 4042 | [email protected]: E:
[email protected], [email protected]: Technical Support:
W: www.yutech.in
Product Code: You can easily decode the product code (PC) as given below:
Example: Product Code of DC Current Isolator having Single Input and Output repeated over two Channels, having DC
Power Supply is If you require AC Power supply, then just replace DC with AC in the ProductA-ISO-DC-C1-C2-S.
Code like A-ISO-AC-C1-C2-S.
Other Abbreviations:
S: Standard Din Rail mounted Enclosure 22.5mm wide
M: Medium Din Rail mounted Enclosure 45 mm wide
DC CURRENT ISOLATOR SINGLE INPUT DUAL OUTPUT
A-ISO-DC-C1-C2-S
A SERIES ISOLATOR
18-36 VDC24 VDC POWER SUPPLY. Use AC for AC Power Supply of 85 to 265 VAC, 50 / 60 Hz.
INPUT 4-20mA, 1 CHANNEL
OUTPUT 4-20mA, 2 CHANNELS
ENCLOSURE WIDTH 22.5mm
Use Isolation Barriers & get relief from Instrumentation and Automation Problems
Protect your Expensive Cards & Automation Systems from electrical noise like floating Voltages &
Switching Surges and Electro-Magnetic Interference (EMI)
Eliminate Ground Reference Faults, Earth Loop Faults and Current Loop Faults
Eliminate Electrical Noise like Radio Frequency Interference (RFI), Common Mode Noise and Harmonic
Distortion generated by Electric Motors, VFDs, DC Drives, Thyristors etc.
Ensure Correct & Stable Readings by Eliminating Separate Ground References.
PLEASE REFER TO ISOLATION PRODUCTS DATASHEETS AND APPLICATION NOGTES FOR DETAILED INFORMATION ON PRODUCTS
.Disclaimer: Isolation Products do not offer Protection against Lightening.
ISOLATION PRODUCTS
DOC NO: YU-br-iso-instr-1005-1