Ysi Mps Brochure

Embed Size (px)

Citation preview

  • 8/8/2019 Ysi Mps Brochure

    1/12

    6-series multiparameter

    water quality sondes

    long-term monitoringproling & spot sampling

    sensor guide

  • 8/8/2019 Ysi Mps Brochure

    2/12

    Top photo: Mike Lizotte

    (let), YSIs US applica-tions specialist, takesoxygen measurementsto spot check sensorperormance on asubmerged monitoringplatorm in BiscayneBay, Florida.

    Bottom: Rigor Ma

    (right), YSI China ap-plications specialist,trains a customer onthe operation o acontinuous monitoringstation in Xiamen,China.

    Why YSI?For 60 years YSI, an employee-owned

    company, has pioneered the developmento water quality sensors or use in natural

    waters.

    Our technology saves youtime: We know that meeting theglobal need or improved environmental

    monitoring requires ewer technical per-

    sonnel and a lower cost o owner-

    ship. YSI provides turn-key monitoring

    solutions, easier to use and install equip-

    ment, and intuitive interaces.

    Our reliability improveseciency: Successul monitoring e-orts depend on accurate and deensible

    data. We deliver reliable instruments

    and continuously develop saeguards

    and system checks to ensure you obtain

    the highest quality data as quickly as

    possible.

    Our employees understandyour challenges: Our technicalsupport sta has extensive feld experi-

    ence which helps them provide hands-on

    support or your monitoring challenges.

    Our customers can reach us:We have 12 global ofces and 250

    employees on 3 continents.

    Our experience is proven:We have the largest installed base o

    multiparameter sondes with over

    20,000 instruments in use worldwide.

  • 8/8/2019 Ysi Mps Brochure

    3/12

    [ 8 0 0 . 8 9 7 . 4 1 5 1 U S

    + 1 9 3 7 7 6 7 7 2 4 1

    Choosing YSIhelps you reduce operating costswithout sacrifcing data accuracy.

    Environmental monitoring takes

    signifcant investments in time and

    money. This investment is jeopardized

    when something goes wrong. Our

    instruments are reliable and make

    your data collection as problem-reeas possible.

    Reduce labor costs through longermaintenance intervals andewer system ailures.

    Do it right the rst timewith our easy-to-use sotware and

    superior technical support.

    Obtain quality data througheatures such as zero calibrations

    on our oxygen sensors and post-

    processing eatures in our sotware.

  • 8/8/2019 Ysi Mps Brochure

    4/12

    multiparameter sondesor long-term monitoring

    YSIs upgraded 6-Series amily includes versatile,multiparameter sondes designed or real-timeenvironmental monitoring and extended deployment.

    V2 SondesAll Version 2 (V2) sondes

    accept our V2 optical

    ensors and have a

    ugged design or long-

    erm monitoring. Theseensors eature anti-

    ouling wipers as well as

    an improved wiping

    algorithm to prevent

    mis-parking.

    Seven V2 sondes are

    oered with sensor

    payloads ranging rom

    5-9 sensors and multiple

    memory and power

    options to accommodate

    many dierent applica-

    ions. In addition to the

    ensor options, YSI

    otware calculates up

    o ve additional

    parameters.

    Virtuallymaintenance-ree Integrated wipedfouling protection for DO,pH, ORP, turbidity, blue-greenalgae, and chlorophyllor rhodamine sensors.

  • 8/8/2019 Ysi Mps Brochure

    5/12

    w w w . y s i . c o m

    [ 8 0 0 . 8 9 7 . 4 1 5 1 U S

    + 1 9 3 7 7 6 7 7 2 4 1

    Source watermonitoring

    Short-term studiesor spot samplingwith completesensor suite

    Dredgingstudies

    Long-termunattendedmonitoring

    Integration intobuoys or verticalproling system

    Underwaysampling with fowcell or horizontalmapping

    6600 V2

    600OMS V2 6820 V2

    6920 V2

    6600 V2 sonde eatures

    the largest sensor payload

    capability and longest

    battery lie. Choose between

    2 and 4 optical ports. The6600 V2 and 6600EDS V2

    are also available with a pH

    wiping system.

    6920 V2 sonde is an

    economical, 15-paramete

    logging system; battery

    powered or long-term, in

    situ monitoring and prolChoose between 1 and 2

    optical ports.

    6820 V2 sonde is a cos

    eective sampling system

    with up to 15-parameter

    reporting capability, idea

    or proling and spot-chec

    ing. Choose between 1 a

    2 optical ports.

    600OMS V2 sonde is our

    smallest V2 sonde, perect

    or applications such as

    turbidity or oxygen monitoring.

    Accepts 1 optical sensor

    as well as conductivity,

    temperature, and depth.

    Applications (suggested uses but not limited to)

    6600 V2-4 with four ports forany combination of these optical

    sensors: ROX dissolved oxygen,blue-green algae, turbidity, chlorophyll,or rhodamine

  • 8/8/2019 Ysi Mps Brochure

    6/12

    multiparameter sondesor monitoring, sampling & logging

    600 SondesYSI 600 sondes are

    designed or specic

    applications where a

    ewer number o

    parameters is required

    and size, ease-o-use,and price are o

    primary concern. All

    ve 600 sondes oer

    a small and economical

    package or water

    quality sampling

    purposes.

    Compact 600sondes have diametersless than 2". The sensors areof the same high qualityoffered on YSI 6000 sondes.

  • 8/8/2019 Ysi Mps Brochure

    7/12

    w w w . y s i . c o m

    [ 8 0 0 . 8 9 7 . 4 1 5 1 U S

    + 1 9 3 7 7 6 7 7 2 4 1

    Source watermonitoring

    600 Sondes

    600LS is our simplest

    sonde, designed or

    spot sampling level

    measurements and tide

    gauge measurements.

    Applications (suggested uses but not limited to)

    Spotsampling

    Short-term,unattendedstudies

    Surace andgroundwatermonitoring

    Water levelmonitoring

    600R includes conductivity

    and temperature sensors

    and options to add pH and

    Rapid PulseTM dissolved

    oxygen. Ideal or largemonitoring programs and

    educational applications.

    The 600QS system

    includes a 600R, 650

    display logger, eld cable,

    and additional sensor

    options such as ORP

    and vented level.

    600XL and 600XLM

    sondes are more versatile,

    ideal or water level monitor-

    ing as well as ground water

    and surace water monitor-ing. Both sondes include

    DO, temperature, and

    conductivity sensors and

    options to add pH or

    pH/ORP, depth, and vented

    level measurements. The

    XLM oers batteries or unat-

    tended, in situ monitoring.

    The newV2 version o

    both sondes has an optical

    sensor port.

    EcoWatch or Windows

    Standard with all YSI sondes, EcoWatch sotware

    makes communication with water quality sensors simple.

    Includes sensor calibration and sonde conguration

    tools as well as basic graphing.

    Data Analysis Sotware

    AQUARIUS Time-Series

    Optional or YSI sondes, AQUARIUS Time-Series

    sotware takes data processing to the next level.

    Includes advanced graphing tools, error detection

    and correction, and modeling capabilities.

  • 8/8/2019 Ysi Mps Brochure

    8/12

  • 8/8/2019 Ysi Mps Brochure

    9/12

    w w w . y s i . c o m

    [ 8 0 0 . 8 9 7 . 4 1 5 1 U S

    + 1 9 3 7 7 6 7 7 2 4 1

    YSI 6-seriesquick select guide

    V2 SondesFeatures/Parameters 600 Sondes Drinking Water Sys

    reshwater only. ** Calculated parameters. lStandard n Customer Selectable sSpecial Order

    l l l l l l l l l

    l l l l l l l l l l l l

    l l l l l l l

    l l l l l l l l l l l l

    l l l n l n l l

    n s n n n n n n n n

    n n s s

    n n n n n

    n n s s

    n n n n n

    l l l l l l l l n l l l

    n n n n n n n n

    n n n n n

    n n n n n

    n n

    n n s s

    n n n n n n n l

    n n n n n n n n n

    s s

    n n n n n n n n n n

    l l l l l l l l n l l l

    n n n n n

    l l l l l l l l n l l l

    l l l l l l l l n l l l

    l l l l l l l l l l l l

    l l l l l l l l n l l l

    n n n n n n

    n n n n n n n l

    eld-replaceable probes

    S-232 & SDI-12 standard

    s 2 wells

    ternal memory

    ternal power (batteries)

    ow cell

    mmonium/ammonia*

    ue green algae

    hloride*

    hlorophyll

    onductivity

    epthssolved oxygen

    ssolved oxygen, optical

    ee chlorine

    trate*

    pen channel fow**

    RP

    AR (Photosynthetically Active Radiation)

    H

    esistivity**

    hodamine

    linity

    pecic conductance**

    mperature

    tal dissolved solids**

    rbidity

    ented level

    6600 6600EDS 6920 6820 600OMS 600R 600XL 600XLM 600LS 6920DW 600DW-B 600

    Available only on 6600 V2-2 Available only on 6920 V2-1 or 6820 V2-1

    Available only on 600XL V2 or 600XLM V2

  • 8/8/2019 Ysi Mps Brochure

    10/12

    high accuracy sensors

    Sensors

    Quality data is the

    product o quality

    sensors and we have

    built our reputation

    on providing thehighest perormance,

    most reliable water

    quality sensors avail-

    able. Our engineers give

    as much attention to

    sensor perormance in

    the laboratory as they

    do to perormance

    under the harshest

    environmental condi-

    tions or extendedperiods. Additionally,

    all YSI sensors are eld

    replaceable, helping

    you with maintenance

    and unexpected

    situations.

    Our optical sensors are

    designed and manuactured

    by YSI. Their excellent per-

    ormance, coupled with inte-

    grated extended deployment

    wipers, oer the longest

    deployment times in the

    industrysaving you time

    and money. Additionally,user-adjustable data ltering

    capabilities allow optimized

    response time or detection

    limits.

    ROX Optical Dissolved

    Oxygen The most reliable,

    accurate, and maintenance-

    ree DO sensor available or

    worry-ree oxygen measure-

    ment.

    Blue-green Algae

    Fluorescence sensors monitor

    blue-green algae biomass inreshwater or marine environ-

    ments in real-time.

    Turbidity Superior linearity,

    1-, 2-, or 3-point calibration

    options and excellent agre

    ment with the industry sta

    benchtop instrument (Hac

    2100AN).

    Chlorophyll Accurately

    tor total algal biomass wit

    intererence rom turbidity

    ambient light, or dissolved

    organics.Rhodamine Conduct dy

    tracing studies (fow, trans

    mixing) with this sensitive

    fuorescence sensor.

    Rapid Pulse Dissolved

    Oxygen The most advancedpolarographic technology

    available, Rapid Pulse DO is

    virtually insensitive to fow

    rate and exhibits large range

    (0-50mg/L). EPA approved

    method.

    pH/ORP Excellent perorm-

    ance in low ionic water.Field-replaceable and

    includes integrated reerence

    electrode. Extended-

    deployment versions with

    wipers available (shown at

    bottom left).

    Measure ammonia,

    nitrate, and chloride.Designed or short-term

    monitoring and spot

    sampling.

    ISE

    Conductivity Superior lin-

    earity and easy one-point

    calibration.

    Temperature Extremely

    accurate, eld-replaceable

    temperature sensor.

    Depth & Vented Level

    Excellent accuracy through

    calibration to extremely high

    precision through temperature

    compensation over the entire

    operating range.

    PAR Integrate the indus-

    try-standard LI-COR PAR

    (Photosynthetically Active

    Radiation) sensor or

    biological studies. Wipe

    PAR also available.

    Optical

    Electrochemical

    Physical

    Ion-selective elect

    Integrated

    ROX Blue-green Algae Turbidity Chlorophyll

    Rapid Pulse DO pH/ORP

    Temp Depth & Level PAR

  • 8/8/2019 Ysi Mps Brochure

    11/12

    Typical perormance specications

    # Maximum depth rating or optical probes is 61 m (200 t). * Freshwater only. Maximum depth rating o 15.2 m (50 t). + Report outputs o specic conductance (conductivity correct to 25 C), resistivity,and total dissolved solids are also provided. These values are automatically calculated rom conductivity according to algorithms ound in Standard Methods for the Examination of Water and Wastewater(ed

    1989). ** To maintain accuracy specication, fow must be at least 500 mL/min and pH should not change by more than 0.3 units i mean pH is between 8.5 and 9.3. ++ Specication determined usingmonocultures o Isochrysis sp. and fuorometric extraction o chlorophyll a. Actual detection limits will vary depending on natural algae assemblage. Estimated rom cultures o Microcystis aeruginosa. Estimated rom cultures o Synechococcus sp.

    Range Resolution Accuracy

    Rapid Pulse dissolved oxygen 0 to 500% 0.1% 0 to 200%: 2% o reading or 2% air% air saturation saturation, whichever is greater; 200 to

    500%: 6% o reading

    Rapid Pulse dissolved oxygen 0 to 50 mg/L 0.01 mg/L 0 to 20 mg/L: 2% o reading or 0.2 mg/Lmg/L whichever is greater; 20 to 50 mg/L: 6%

    o reading

    ROX optical dissolved oxygen# 0 to 500% 0.1% 0 to 200%: 1% o reading or 1% air% air saturation saturation, whichever is greater; 200 to 500

    15% o reading; relative to calibration gas

    ROX optical dissolved oxygen# 0 to 50 mg/L 0.01 mg/L 0 to 20 mg/L: 1% o reading or 0.1 mg/Lmg/L whichever is greater; 20 to 50 mg/L: 15%

    o reading; relative to calibration gases

    Conductivity+ 0 to 100 mS/cm 0.001 to 0.1 mS/cm 0.5% o reading + 0.001 mS/cm(range-dependent)

    Temperature -5 to 50C 0.01C 0.15C

    pH 0 to 14 units 0.01 unit 0.2 unit

    Shallow depth 0 to 9.1 m (0 to 30 t) 0.001 m (0.001 t) 0.018 m (0.06 t)

    Medium depth 0 to 61 m (0 to 200 t) 0.001 m (0.001 t) 0.12 m (0.4 t)

    Deep depth 0 to 200 m (0 to 656 t) 0.001 m (0.001 t) 0.3 m (1 t)

    Vented level 0 to 9.1 m (0 to 30 t) 0.001 m (0.001 t) 0.003 m (0.01 t)

    Open-channel fow Calculated measurement, requires vented level

    Free chlorine 0 to 3 mg/L 0.01 mg/L 15% o reading or 0.05 mg/L, whichever is greater

    ORP -999 to +999 mV 0.1 mV 20 mV in Redox standard solutions

    Salinity 0 to 70 ppt 0.01 ppt 1% o reading or 0.1 ppt,whichever is greater

    Nitrate/nitrogen* 0 to 200 mg/L-N 0.001 to 1 mg/L-N 10% o reading or 2 mg/L,(range dependent) whichever is greater

    Ammonium/ammonia/ 0 to 200 mg/L-N 0.001 to 1 mg/L-N 10% o reading or 2 mg/L,nitrogen* (range dependent) whichever is greater

    Chloride* 0 to 1000 mg/L 0.001 to 1 mg/L 15% o reading or 5 mg/L,(range dependent) whichever is greater

    Turbidity# 0 to 1,000 NTU 0.1 NTU 2% o reading or 0.3 NTU, whichever isgreater in YSI AMCO-AEPA Polymer Standards

    Rhodamine WT# 0-200 mg/L 0.1 mg/L 5% o reading or 1 mg/L,whichever is greater

    Range Resolution LinearityChlorophyll# ++ 0 to 400 mg/L chl a 0.1 mg/L chl a R2 > 0.9999 or serial dilution o Rhodamin

    0 to 100 RFU 0.1% FS; 0.1 RFU WT solution rom 0 to 500 mg/L

    Range Detection limit LinearityBlue-green algae# 0-280,000 cells/mL 220 cells/mL R2 = 0.9999 or serial dilution o Rhodaminphycocyanin WT rom 0 to 400 mg/L

    Blue-green algae# 0-200,000 cells/mL 450 cells/mL R2 = 0.9999 or serial dilution o Rhodaminphycoerythrin WT rom 0 to 8 mg/L

    Range Calibration StabilityPAR 400-700 nm waveband 5%

  • 8/8/2019 Ysi Mps Brochure

    12/12

    To order or or more inormation,contact YSI Environmental.

    800 897 4151

    www.YSI.com

    YSI Environmental1700/1725 Brannum LaneYellow Springs, Ohio 45387+1 937 767 7241+1 937 767 9353 ax

    [email protected]

    YSI Integrated Systems & Services+1 508 748 0366+1 508 748 2543 [email protected]

    YSI Gul Coast+1 225 753 2650+1 225 753 8669 [email protected]

    SonTek/YSI+1 858 546 8327

    +1 858 546 8150 [email protected]

    ISO 9001

    ISO 14001(Yellow Springs facility)

    Pure Data or a Healthy Planet, ROX, andWhos Minding the Planet? are registeredtrademarks and Rapid Pulse is a trademark oYSI Incorporated. Windows is a registeredtrademark o Microsot Corporation. LI-COR isa registered trademark o LI-COR Biosciences.AQUARIUS Time-Series is a trademark oAquatic Inormatics.

    2008 YSI IncorporatedE23-07 0108 Printed in the USA

    YSI HydrodataEuropean Support Centre (UK)+44 1462 673581+44 1462 673582 [email protected]

    YSI (Hong Kong) Limited+852 2891 8154+852 2834 0034 [email protected]

    YSI Middle East+973 17536222+973 17536333 [email protected]

    YSI/Nanotech (Japan)+81 44 222 0009+81 44 221 1102 ax

    [email protected]

    YSI China+86 10 5203 9675+86 10 5203 9679 [email protected]

    Third-Party SensorVerication YouCan TrustYSI is the only company in itseld to apply or and receiveverication rom the US EPAsEnvironmental TechnologyVerication Program. Indepen-dent tests on the ollowingsensors demonstrated theaccuracy o YSI sensortechnology when comparedto established standards insaltwater and reshwater:

    6025 Chlorophyll6560 Conductivity

    6562 Dissolved Oxygen6561 pH6560 Temperature6136 Turbidity

    Sensors listed above were submitted to

    ETV program on YSI 6600EDS. Find

    inormation on perormance character-

    istics o YSI water quality sensors at

    www.epa.gov/etv or call YSI at +1

    937 767 7241 or ETV Verication

    Report. Use o the ETV name or logo

    does not imply approval or certica-

    tion o this product nor does it make

    any explicit or implied warranties orguarantees as to product perormance.

    Pure Data or a Healthy Planet.Y S I Environmental

    Y S I i n c o r p o r a t e d Whos Minding the Planet?