24
RESIDENTIAL HORIZONTAL CLADDING www.metalcraftgroup.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] Metalcraft Roofing Bevelback Weatherboard RHBW 00 / 23 COVER SHEET 01 / 23 PARAPET AND BALUSTRADE CAPPING 02 / 23 SOFFIT 03 / 23 FLUSH WINDOW HEAD 04 / 23 FLUSH WINDOW SILL 05 / 23 FLUSH WINDOW JAMB 06 / 23 RECESSED WINDOW HEAD 07 / 23 RECESSED WINDOW SILL 08 / 23 RECESSED WINDOW JAMB 09 / 23 BUTT WINDOW HEAD 10 / 23 BUTT WINDOW SILL 11 / 23 BUTT WINDOW JAMB 12 / 23 METERBOX HEAD 13 / 23 METERBOX SILL 14 / 23 METERBOX JAMB 15 / 23 INTERNAL CORNER 16 / 23 EXTERNAL CORNER 17 / 23 INTERNAL CORNER BOX TYPE 18 / 23 EXTERNAL CORNER BOX TYPE 19 / 23 SOAKER FLASHING 20 / 23 VERTICAL BUTT JOINT 21 / 23 BOTTOM OF CLADDING (FLUSH) 22 / 23 BOTTOM OF CLADDING (RECESSED) 23 / 23 3D WINDOW FLASHINGS DETAIL LIST

Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected]

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

RESIDENTIAL HORIZONTAL CLADDING

www.metalcraftgroup.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

MetalcraftRoofing

Bevelback Weatherboard

RHBW

DETAIL LIST

00 / 23 COVER SHEET01 / 23 PARAPET AND BALUSTRADE CAPPING02 / 23 SOFFIT03 / 23 FLUSH WINDOW HEAD04 / 23 FLUSH WINDOW SILL05 / 23 FLUSH WINDOW JAMB06 / 23 RECESSED WINDOW HEAD07 / 23 RECESSED WINDOW SILL08 / 23 RECESSED WINDOW JAMB09 / 23 BUTT WINDOW HEAD10 / 23 BUTT WINDOW SILL11 / 23 BUTT WINDOW JAMB12 / 23 METERBOX HEAD13 / 23 METERBOX SILL14 / 23 METERBOX JAMB15 / 23 INTERNAL CORNER16 / 23 EXTERNAL CORNER17 / 23 INTERNAL CORNER BOX TYPE18 / 23 EXTERNAL CORNER BOX TYPE19 / 23 SOAKER FLASHING20 / 23 VERTICAL BUTT JOINT21 / 23 BOTTOM OF CLADDING (FLUSH)22 / 23 BOTTOM OF CLADDING (RECESSED)23 / 23 3D WINDOW FLASHINGS

DETAIL LIST

Page 2: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PRE-FINISHED PARAPET CAP FLASHINGNO FIXINGS ON TOP OF FLASHING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

CONTINUOUS H3.1 TIMBER PACKINGTO GIVE 5° FALL INWARDS

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

WALL FRAMING

MIN

. 5.00 °PERMEABLE WALL UNDERLAY TO PROVIDESEPARATION OF METAL CAPPING ANDCLADDING WITH TIMBER, SHOWN DASHED

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

20mm CAVITY

Z

CLE

ARAN

CE

3mm

MIN

CLE

ARAN

CE

25m

m

Z

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCLADDING AND BATTEN AS NECESSARY

PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Z

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

SITUATION 1

1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°

MIN. 50mm

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 70mmZ

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

MIN. 90mm

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

PARAPET AND BALUSTRADE CAPPING

01 / 232018

Page 3: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDRLAY, SHOWNDASHED

20mm CAVITY

WALL FRAMING

METALCRAFT BEVELBACKWEATHERBOARD PROFILE

PRE-FINISHED SOFFIT FLASHING

FLY RAFTER

BARGE BOARD

SOFFIT LINING

PURLIN

INTERNAL CEILING LINING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

EXTRA NOG FOR TOP FIXING OFWALL CLADDING

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCLADDING AND BATTEN AS NECESSARY

INTERNAL WALL LINING

SQUARE STOP CORNICE

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL

Z

50mm MINSTSR OR GALV. FLATHEAD NAIL FOR FLASHING

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Z

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

SITUATION 1

1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°

MIN. 50mm

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 70mmZ

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

MIN. 90mm

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

SOFFIT

02 / 232018

Page 4: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT HEAD

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED

INTERNAL WALL LINING

WINDOW LINTEL FRAMING

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

DOUBLE GLAZING WINDOWJOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMB LINER BEHIND

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PVC CAVITY CLOSER

COMPRESSIBLE FOAM SEAL TOFILL OVERLAP OF FLASHING

MIN

. 10m

m C

OVE

R

SUG

GES

T M

IN. 5

0mm

DIM

ENSI

ON

TO

SU

IT

MIN

. 75m

m W

I TH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL

5 m

m G

AP

DR

IP E

DG

E TO

CLA

DD

ING

MIN

. 15

mm

GAP

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

FLUSH WINDOW HEAD

03 / 232018

Page 5: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

INTERNAL WALL LINING

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW JAMB LINER BEHIND

WINDOW SILL LINER

MIN. 8mm PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL

PRE-FINISHED WINDOW SILL FLASHING

WALL FRAMING

PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT SILL

STOPENDS TO SILL FLASHING

LINE OF JAMB FLASHING BEHIND

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

20mm CAVITY

WINDOW SUPPORT BAR

PRE-FINISHED SECONDARY FLASHING

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHING ANDCLADDING WITH TIMBER, SHOWNDASHED

PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL

MIN

. 8m

m C

OVE

R

5mm GAP

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

50m

m C

OVE

R

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

FLUSH WINDOW SILL

04 / 232018

Page 6: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW SILL LINER BELOW

WINDOW JAMB LINER

TIMBER PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

INTERNAL WALL LINING

LINE OF SILL FLASHING BELOW

PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL

FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL

20mm CAVITY

LINE OF SILL FLASHING BELOW

PRE-FINISHED WINDOW JAMBFLASHING

COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING AT HEAD FLASHING

MIN. 10mm COVER

5mm

GAP

PRE-FINISHED SECONDARY FLASHING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

STST OR GALV. FLAT HEAD NAIL FORFLASHING

SUGGEST MIN. 50mm

DIMENSION TO SUIT

LINE OF HEAD FLASHING ABOVE

CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER, SHOWNDASHED

LINE OF HEAD FLASHING ABOVE

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

FLUSH WINDOW JAMB

05 / 232018

Page 7: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED

INTERNAL WALL LINING

WINDOW LINTEL FRAMING

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

DOUBLE GLAZING WINDOW JOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMB LINER BEHIND

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND

PVC CAVITY CLOSER

STST OR GALV. FLAT HEAD NAIL FORFLASHING

SUG

GES

T M

IN. 5

0mm

DIM

ENSI

ON

TO

SU

IT

20mm CAVITY

MIN

. 10m

m C

OVE

R

PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL

5 m

m G

AP

DR

IP E

DG

E TO

CLA

DD

I NG

MIN

. 15m

m G

AP

MIN

. 75m

m W

I TH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

RECESSED WINDOW HEAD

06 / 232018

Page 8: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

5mm GAP

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

INTERNAL WALL LINING

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW JAMB LINER BEHIND

WINDOW SILL LINER

MIN. 8mm PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

PRE-FINISHED WINDOW SILL FLASHING

WALL FRAMING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

STOPENDS TO SILL FLASHING

LINE OF JAMB FLASHING BEHIND

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

20mm CAVITY

WINDOW SUPPORT BAR

PRE-FINISHED SECONDARY FLASHING

SEPERATE BATTEN AND CLADDINGWITH DPC AS REQUIRED

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL

5mm

GAP

MIN

. 8m

m C

OVE

R

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL

PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

CO

VER

CLA

DD

ING

50m

m(3

5mm

MIN

)

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

RECESSED WINDOW SILL

07 / 232018

Page 9: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PRE-FINISHED WINDOW JAMBFLASHING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW SILL LINER BELOW

WINDOW JAMB LINER

TIMBER PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

INTERNAL WALL LINING

LINE OF SILL FLASHING BELOW

FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL

CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION3.0 /2017 FOR REQUIREMENT.

METALCRAFT BEVELBACKWEATHERBOARD PROFILE

PRE-FINISHED SECONDARYFLASHING

PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED

STST OR GALV. FLAT HEAD NAILFOR FLASHING

LINE OF HEAD FLASHING ABOVE

LINE OF HEAD FLASHING ABOVE

MIN. 10mm COVER

5mm GAP

SUGGEST MIN. 50mm

DIMENSION TO SUIT

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

RECESSED WINDOW JAMB

08 / 232018

Page 10: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED

INTERNAL WALL LINING

WINDOW LINTEL FRAMING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

DOUBLE GLAZING WINDOW JOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMB LINER BEHIND

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND

PVC CAVITY CLOSER

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

DR

IP E

DG

E TO

CLA

DD

I NG

MIN

. 15m

m G

AP

MIN

. 75m

m W

I TH

OU

T H

EM E

DG

E

MIN

. 50M

M C

OVE

RSU

GG

EST

MIN

. 50m

m

DIM

ENSI

ON

TO

SU

IT

MIN

. 10m

m C

OVE

R

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

5 m

m G

APReference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

BUTT WINDOW HEAD

09 / 232018

Page 11: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

INTERNAL WALL LINING

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW JAMB LINER BEHIND

WINDOW SILL LINER

MIN. 8mm PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL

PRE-FINISHED WINDOW SILL FLASHING

WALL FRAMING

PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT SILL

STOPENDS TO SILL FLASHING

LINE OF JAMB FLASHING BEHIND

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

20mm CAVITY

WINDOW SUPPORT BAR

PRE-FINISHED SECONDARY FLASHING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREWPERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER,SHOWN DASHED

5mm

GAP

MIN

. 8m

m C

OVE

R

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

5mm GAP

CO

VER

CLA

DD

ING

50m

m(M

IN. 3

5mm

)

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

BUTT WINDOW SILL

10 / 232018

Page 12: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW SILL LINER BELOW

WINDOW JAMB LINER

TIMBER PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

INTERNAL WALL LINING

LINE OF SILL FLASHING BELOW

FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL

CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.

PRE-FINISHED WINDOW JAMBFLASHING

5mm GAP5mm GAP

MIN. 50mm MIN. 10mm COVER

5mm

GAP

STST OR GALV. FLAT HEAD NAILFOR FLASHING

PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING AND CLADDINGWITH TIMBER, SHOWN DASHED

SUGGEST MIN.50mm

DIMENSION TO SUIT

LINE OF HEAD FLASHING ABOVE

LINE OF HEAD FLASHING ABOVEPRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

BUTT WINDOW JAMB

11 / 232018

Page 13: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD

TEMPORARY PACKER IF REQUIRED, REMOVEDAFTER FIXING

PRE-FINISHED HEAD FLASHING WITH 15° FALL

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

METER BOX

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND

METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.

PRE-FINISHED 'U' BRACKET FIXED TOMETERBOX BEFORE INSTALLATION

EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED

INTERNAL WALL LINING

PVC CAVITY CLOSER

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-FINISHED SELF-TAPPING TEK SCREWWITH RUBBER WASHER

MIN

.75m

m W

ITH

OU

T H

E M E

DG

E

MIN

.50m

m C

OVE

R

DR

IP E

DG

E TO

CLA

DD

I NG

MIN

. 15m

m G

AP

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

5 m

m G

APReference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

METERBOX HEAD

12 / 232018

Page 14: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

METER BOX

INTERNAL WALL LINING

MIN. 8mm PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WALL FRAMING

20mm CAVITY

LINE OF JAMB FLASHING BEHIND

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.

PRE-FINISHED FLASHING

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

STOPENDS TO SILL FLASHING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

CO

VER

CLA

DD

ING

50m

m(M

IN.3

5mm

)

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

METERBOX SILL

13 / 232018

Page 15: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

METER BOX

TIMBER PACKER

INTERNAL WALL LINING

LINE OF SILL FLASHING BELOW

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED WINDOW JAMB FLASHING FIXEDTO METERBOX BEFORE INSTALLATION

PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

METAL ANGLE TO BE CONTINUOUS AROUNDMETER BOX WITH PRE-FINISHED SELFDRILLING/TAPPING SCREW WITH RUBBERWASHER

CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED

STST OR GALV. FLAT HEAD NAILFOR FLASHING

PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

SUGGEST MIN. 50mm

DIMENSION TO SUIT

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

WINDOW JAMB FLASHINGFIXED TO METAL ANGLE

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

METERBOX JAMB

14 / 232018

Page 16: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

WALL FRAMING

20mm CAVITY

PRE-FINISHED INTERNALCORNER FLASHING

INTERNAL WALL LINING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

PERMEABLE WALL UNDERLAY, SHOWNDASHED

SUG

GES

T M

IN. 7

5mm

DIM

ENSI

ON

TO

SU

IT

SUGGEST MIN. 75mm

DIMENSION TO SUIT

CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHING ANDCLADDING WITH TIMBERM, SHOWNDASHED

PRE-FINISHED SECONDARY FLASHING

PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

INTERNAL CORNER

15 / 232018

Page 17: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

20mm CAVITY

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

INTERNAL WALL LINING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

WALL FRAMING

PRE-FINISHED EXTERNALCORNER FLASHING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION 3.0/2017 FOR REQUIRMENT.

PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED

PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PRE-FINISHED SECONDARYFLASHING

SUGGEST MIN. 75mm

DIMENSION TO SUIT

SUG

GES

T M

IN. 7

5mm

DIM

ENSI

ON

TO

SU

IT

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

EXTERNAL CORNER

16 / 232018

Page 18: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

WALL FRAMING

20mm CAVITY

PRE-FINISHED INTERNAL CORNERFLASHING

INTERNAL WALL LINING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

PERMEABLE WALL UNDERLAY,SHOWN DASHED

MIN. 50mm COVER

MN

. 50m

m C

OVE

RCONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.

STST OR GALV. FLAT HEAD NAIL FORFLASHING

5mm

GAP

5mm GAP

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER, SHOWNDASHED

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

INTERNAL CORNER BOX TYPE

17 / 232018

Page 19: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

20mm CAVITY

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

INTERNAL WALL LINING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

WALL FRAMING

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED

MIN. 50mm COVER

MIN

. 50m

m C

OVE

R5mm

GAP

5mm GAP

PERMEABLE WALL UNDERLAY, SHOWNDASHED

PRE-FINISHED EXTERNAL CORNERFLASHING

CONTINUOUSCOMPRESSIBLE FOAM SEAL.REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017FOR REQUIRMENT.

STST OR GALV. FLAT HEAD NAIL FORFLASHING

MIN

. 70m

m

MIN. 70mm

PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

EXTERNAL CORNER BOX TYPE

18 / 232018

Page 20: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALL UNDERLAY,SHOWN DASHED

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-FINISHED FLAT HEADWAFER-TEK SCREW FORFLASHING

INTERNAL WALL LINING

20mm CAVITY

WALL FRAMING

PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORLUG NAIL

PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED

SOAKER FLASHING ONLY REQUIREDTO LINE UP WITH WINDOW JAMBABOVE.REFER TO MRM CODE OF PRACTICEVERSION 3.0 /2017 FOR REQUIRMENT.

80

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

SOAKER FLASHING

19 / 232018

Page 21: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

PERMEABLE WALLUNDERLAY, SHOWN DASHED

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL

INTERNAL WALL LINING

WALL FRAMING

PRE-FINISHED JOINTERFLASHING

PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED

5mm GAP

MIN. 50mm COVER

CONTINUOUSCOMPRESSIBLE FOAMSEAL. REFER TO MRM CODEOF PRACTICE VERSION 3.0/2017 FOR REQUIRMENT.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

VERTICAL BUTT JOINT

20 / 232018

Page 22: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

20mm CAVITY

INTERNAL WALL LINING

WALL FRAMING

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PRE-PRIMED SKIRTING

CONCRETE SLAB

PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED

PVC CAVITY CLOSER

MIN

. 15m

m D

RIP

ED

GE

MIN

. 50m

m L

AP

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL

BOTTOM PLATE ON DPC

VEN

TILA

TIO

N G

AP

5 m

m

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

BOTTOM OF CLADDING (FLUSH)

21 / 232018

Page 23: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

INTERNAL WALL LINING

WALL FRAMING

PVC CAVITY CLOSER

PRE-PRIMED SKIRTING

CONCRETE SLAB

MIN

. 50m

m L

AP

20mm CAVITY

METALCRAFT BEVELBACKWEATHERBOARD CLADDING

PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED

ALTERNATIVE OPTIONBIRDS BEAK EDGE

5 GAP

20

15

PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL

HEMMED EDGE

VEN

TILA

TIO

N G

AP

5 m

m

BOTTOM PLATE ON DPC MIN

. 75m

m C

OVE

R

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW 1 : 2

BOTTOM OF CLADDING (RECESSED)

22 / 232018

Page 24: Y:RevitMdurrantRHBB Residential Horizontal …...RESIDENTIAL HORIZONTAL CLADDING Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: Frances.charles@unitedindustries.co.nz

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL HORIZONTAL CLADDING

ScaleDate SheetMetalcraftRoofing

Bevelback Weatherboard

RHBW

3D WINDOW FLASHINGS

23 / 232018

HEAD FLASHING

JAMB FLASHING

SILL FLASHING

METALCRAFTBEVELBACKWEATHERBOARDCLADDING

ALUMINIUMWINDOWJOINERY

COMPRESSIBLEFOAM SEALBEHIND TO FILLOVERLAP OFFLASHING

FLUSH WINDOW FLASHINGS RECESSED WINDOW FLASHINGS

HEAD FLASHING

JAMB FLASHING

ALUMINIUMWINDOWJOINERY

SILL FLASHING

METALCRAFTBEVELBACKWEATHERBOARDCLADDING