Your Partner of Choice Straumann Authenticity
Name, Function (Arial 20p)
Event, Date (Arial 20p)
Straumann 2
The implant-abutment connection may be of great importance for long-term stability and successful outcome of a restoration.
The combination of Straumann abutments on Straumann implants is designed to achieve the best possible performance of the implant-abutment connection and therefore of the entire restoration.
Straumann 3
Implant-Abutment Connection
Importance
Straumann® Connections
Risks of Mix and Match
Straumann 4
Genuine vs. compatible components
Genuine components are original components designed and manufactured by a company to fit harmoniously into another original component by the same company.
‘Compatible’ components are designed to fit into another company’s genuine - often patented - component. However to get around the patent, the ‘compatible’ part needs to be made differently than the original design. This can increase the risk of complications.
Genuine Components: Restorative Success
Straumann 5
Avoid peak stressesConical screw head
Sealed connectionConical implant-abutment interface
Precise guidance at assemblyRadial contact surfaces
High stabilityDeep implant-abutment engagement
1
2
3
4
Benefits of Using Genuine Components
1
2
3
4
Straumann 6
1. Avoid Peak Stresses
1
Straumann 7
1. Avoid Peak Stresses
Connection design
Conical screw head is designed to offer the clinician additional benefits:
- High resistance to lateral forces
- Even load distribution
- Distribution of anti-rotational and bendingforces
- Even stress distribution to avoid peak stresses
- Minimizes loosening or breakage of the screw
1
Data on file
Straumann 8
2. Sealed Connection
Conical implant-abutment interface offersthe clinician the following benefits:
- Supports mechanical stability of systemto lateral forces
- Helps ensure proper seating of the abutment
- Designed to provide a seal against bacterialcontamination, minimizing the microgap
- Designed to reduce the risk of micromovements
2
Data on file
Straumann 9
2. Sealed Connection
Relation to crestal bone maintenance
Microgap measurements
Mechanical stability of system to lateral forces
Strength to withstand chewing forces
Bone must be stimulated in a certain range to be maintained and not overused
Designed to reduce bone resorption
Any implant-abutment gap from unharmonized tolerances or mismatched components may cause bacterial infiltration and accumulation, which may impact treatment success
Data on file
Straumann 10
Microgap Measurements
Problem statement
A microgap can cause bacterial contamination and micro-movements
How it was investigated
Cut and polished micrographs
Scanning electron microscopy
Data on file
Straumann 11
Microgap Measurements
Representative polished micrograph section(magnification: left 50×; right 2500×)Data on file
Straumann 12
Microgap Measurements
Results and conclusion
Microgap is below 1µm (0.6 ± 0.3 µm)
Such as small Microgap is intended to prevent bacterial contamination, which is important for crestal bone maintenance
Data on file
Straumann 13
3. Precise Guidance at Assembly
Microgap is below 1µm (0.6 ± 0.3 µm)
Such as small Microgap is intended to prevent bacterial contamination, which is important for crestal bone maintenance No additional X-ray needed to verify if impression post or abutment screw is fully seated
3
X-rays courtesy of Dr. Robert Margeas, DDS, Des Moines, IA
Abutment screw fully seated
Straumann 14
4. High Stability
Deep implant-abutment engagement
All parts function together as intended
Excellent fatigue strength
Harmonized dimensional tolerances
High-quality materials compatible with each other (screw, implant, abutment) to avoid contact corrosion
Straumann® guarantees the composition of their materials - Straumann cannot guarantee what materials are used by other manufacturers
4
Data on file
Straumann 15
3. Precise Guidance at Assembly
Assembly only possible in its correct orientation
Precise abutment placement
Radial contact surfaces
Tactile feedback when fully assembled
Compensates for low visibility
3
Straumann 16
Genuine Components Summary
Genuine components are designed to offer technicians and clinicians the following advantages:
- Provide restorations for an excellent outcome
- All parts function together as intended
- Minimize loosening or breakage of the screw
- Help ensure proper seating of the abutment
- Provide a seal against bacterialcontamination, minimizing the microgap
Competitors can only assume dimensions and tolerances of Straumann components
Straumann® support for hands-on training, educational events, business consulting and more
Straumann 17
Implant-Abutment Connection
Importance
Straumann® Connections
Risks of Mix and Match
Straumann 18
Straumann Implant-Abutment Connection
Straumann® synOcta® Morse taper connection
Straumann Bone Level CrossFit® connection
Tissue Level Implants Bone Level Implants
Straumann 19
Straumann Implant-Abutment ConnectionsDesigned to:
Ensure optimal load distribution to reduce peak stresses
Minimize the infiltration of bacteria and contamination in micro-gaps
Have a design harmony between abutment, screw and implant to provide optimal mechanical performance and long-term stability of a restoration
Ensure simple handling of abutments and screws during the assembly process
Straumann 20
Straumann Implant-Abutment Connections
Straumann delivers products built on specialization, reliability and simplicity
Genuine components are backed by our Straumann Guarantee.
With Straumann’s Bone Control Design® and unique CrossFit® Connection, the bone level implant and abutment are designed to seamlessly connect for long-lasting, beautiful esthetics.
Straumann parts have undergone mechanical testing and have been engineered precisely to function in a particular mechanical configuration.
Straumann 21
Mouth situation
Strength Tests
Two extremes:
A) Biting once on a hard object
(e.g. stone pit in fruit)- single incident
- very high forces
B) Years of chewing - millions of cycles
- low to moderate forces
Fatigue strength• intricate simulation• up to 2 weeks of testing• reference: competitors
Ultimate strength• simple test• fast
Laboratory situation
Straumann 22
Conclusion Fatigue Strength
BL Ø 4.8 mm, RC
BL Ø 3.3 mm, NC
BL Ø 4.1 mm, RC
Market average
Straumann®
Bone Level
shoulder diameter [mm]
fatig
ue
str
en
gth
[N
]
0
50
100
150
200
250
300
350
400
450
500
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Data on file
Straumann 23
Combined Benefits of Genuine Components Bone Control Design® - Based on 5 key Biological Principles
Straumann 24
Combined Benefits of Genuine Components Confidence with CrossFit® Connection
Prosthetic flexibility and stability through a deep conical connection
Clear-cut insertion through the guidance of 4 grooves
Designed to prevent rotation
Straumann 25
CrossFit® ConnectionRespects Straumann® strengths: simplicity
Clear-cut insertion through the guidance of 4 grooves
Straumann 26
CrossFit® ConnectionRespects Straumann strengths: stability and precision
15° conical connection
4 protrusions
Straumann 27
≤ 30°
15° cone
CrossFit® ConnectionRespects Straumann® strengths: flexibility
Straumann 28
Limitations of Competitor Design
Competitor abutments are not designed using Straumann’s precise engineering specifications
The square-shaped connection, shown here, provides surface contact with only the protrusions and can undermine security
The resulting imprecise fit leaves gaps that can lead to compromised performance
Straumann 29
Straumann® - The Confident Choice
Lifetime limited warranty for implants
5 year warranty for ceramic abutments*
10 year limited warranty for metal abutments*
Conditions:
For implants placed at or after April 01, 2011
Straumann products must be used exclusively with other Straumann products and not in combination with any other manufacturer product
Other conditions apply
*Guarantee includes screw retained bars and bridges and Straumann CARES copings, crowns and bridges
Straumann 30
Implant-Abutment Connection
Importance
Straumann® Connections
Risks of Mix and Match
Straumann 31
The Risks of Mixing Straumann® Implants with Non-Straumann Abutments
Non-Straumann abutments cannot satisfy Straumann’s strict design and engineering specifications.
Any compromise in the abutment-implant connection can lead to complications including micro-gap bacterial colonization shown to cause bone loss or even a failed implant.
To protect the integrity of your procedure choose components designed for optimal precision.
Straumann 32
Identifying the Cost of Compromise*Potential Failure Costs Due to Use of Non-Straumann® Abutment on Straumann Implant
Avg. Estimated Hours
SURGICAL COSTS
Chairtime for explantation 1.5
Regeneration materials 0.25 – 1.0
Chairtime for re-implantation 1.0
Cost of Implant and healing components
Lost opportunity /revenue due to extension of treatment time and additional patient visits
Loss of patient
RESTORATIVE COSTS
Chairtime for impression, temporization and follow-up 3.0
Cost of abutment
Cost of Impression components and materials
Lost opportunity /revenue due to extension of treatment time and additional patient visits
Loss patient
DENTAL LABORATORY COSTS
Labor 1.0
Materials cost*Assumption: Replacement of single implant
Straumann 33
Is it Straumann? How to Tell
Straumann 34
Is It Straumann®? How to Tell
Our custom abutments bear distinguishing marks that make it easy to be sure you’re using authentic Straumann components.
For Straumann ZrO2 CADCAM components (top row), look for the black laser line around the screw shaft.
For both ZrO2 and Straumann Ti CADCAM components, look for the distinctive yellow and purple tops.
The more you know, the more confident you can feel.
Yellow Magenta
Straumann 35
THE CONFIDENT CHOICETHE CONFIDENT CHOICE
Straumann 36
Presentation links
Straumann Prosthetics Overview
TL Restorations (procedures detail)
BL Restorations (procedures detail)
Authenticity