Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
PAGE 02 Rev 1
Thank you for taking time to look at our
product catalogue.
Please note that Legacy Fire also provide the
following services
SPECIAL BUILD OF FIRE DETECTION EQUIPMENT
( interface enclosures, custom built key switch units for
isolations etc.)
FIRE ALARM DESIGN
FIRE ALARM SERVICING/TESTING
FIRE ALARM/DISABLED REFUGE COMMISSIONING
FIRE ALARM FAULT FINDING
PRODUCT TRAINING OF ALL SUPPLIED
EQUIPMENT
INHOUSE PRODUCT SUPPORT
If there is any other type of equipment you would like a quote for that is
not shown in this catalogue please give us a call or send an e-mail to the
following:
PHONE CONTACTS
MARTYN CASTREE: 07947 177205
RICHARD PARKES : 07853329753
E-MAIL CONTACTS
PAGE 03 Rev 1
CONTENTS TITLE DESCRIPTION PAGE
QUATRO ADDRESSABLE EN54 /CPD APPROVED ADDRESSABLE FIRE PANEL 4
SIMPLICITY PRE CONFIGURED ADDRESSABLE PANEL 5
FYREYE EXTRA
DEVICES
ADDRESSABLE DETECTORS AND CALL POINTS 6,7
ADDRESSABLE INTERFACES AND SOUNDERS 8-10
FIRECLASS
ADDRESSABLE
FIRECLASS DIGITAL PROTOCOL ADDRESSABEL PANEL RANGE 11
FIRECLASS ADDRESSABLE DETECTORS , CALL POINTS ,
INTERFACES,SOUNDERS
12-14
DISCOVERY/VOYAGER
ADDRESSABEL
DISCOVERY/VOYAGER RANGE OF PANELS 15
APOLLO ADDRESSABLE DETECTORS, CALL POINT AND
INTERFACES
16,17
APOLLO ADDRESSABLE RANGE OF SOUNDERS 18,19
INFINITY EN54/CPD APPROVED CONVENTIONAL PANEL 20
FYREYE MKII CONVENTIONAL DETECTORS, SOUNDERS AND
CALL POINT
21-23
CB200 1,2,4 AND 8 ZONE CONVENTIONAL PANEL 24
FIRECLASS PRECFEPT EN EN54/CPD APPROVED CONVENTIONAL PANEL 25
FIRECLASS CONVENTIONAL DETECTORS 26
APOLLO CONVENTIONAL DETECTORS/CALL POINT 27
CONVENTIONAL SOUNDERS AD MISC DEVICES 28,29
DUO-CEL 2 WIRE CONVENTIONAL 2 WIRE PANEL AND DEVICES 30
PREMIER EX8 CONVENTIONAL GAS EXTINGUIHANT PANEL 31
FIRECLASS PRESCIENT 3 CONVENTIONAL GAS EXTINGUIHANT PANEL 32
PSU ‘S POWER SUPPLY UNITS BOXED AND UNBOXED VERSIONS 33
DISABLED REFUGE FIRETELEPHONE AND DISABLED REFUGE SYSTEM, DISABLED
TOILET ALARM
34
BATTERY SETS 12V BATTERIES FOR YOUR FIRE/DISABLED REFUGE/LIGHTING 35
EMERGENCY LIGHTING EMERGENCY LIGHTS AND SIGNS 36
PAGE 04 Rev 1
QUATRO ANALOGUE ADDRESSABLE
Available in 1,2,3 or 4 loop versions.
Approved to EN54 parts 2 and 4.
Compatible with Fyre extra addressable field devices.
Networkable up to 64 panels
250 programmable zones
Pc configurable
Ancillaries available include Graphical alarm
manager, desktop printer and flush mount stainless
steel enclosures
Quatro 1 loop Analogue Addressable
Control Panel
Part no
LF2000-001
Quatro 2 loop Analogue Addressable
Control Panel
Part no
LF2000-002
Quatro 3 loop Analogue Addressable
Control Panel
Part no
LF2000-003
Quatro 4 loop Analogue Addressable
Control Panel
Part no
LF2000-004
Quatro Repeater Panel Part no
LF2000-005
NEW
PAGE 05 Rev 1
SIMPLICITY ADDRESSABLE
Designed with ease of use in mind by using pre-programmed
values for its programming options. The installer simply needs to
configure loop and enter device texts via the built in keypad.
Option of zonal or common alarm operation
Alarm verification (helps prevent false alarms)
No need for programming tools or laptop for commissioning
Complies fully to EN54 parts 2 & 4.
SP-64 Simplicity Plus 64 Analogue
Addressable Control Panel (can support
up to 64 addressable devices with 4 zones)
Part no
LF2000-051
SP-126 Simplicity Plus 126
Analogue Addressable Control Panel (can support up to 126 addressable devices with 8
zones)
Part no
LF2000-052
SP-252 Simplicity Plus 252
Analogue Addressable Control Panel (can support up to 252 addressable devices with 8
zones over 2 loops)
Part no
LF2000-053
NEW
PAGE 06 Rev 1
FYREYE EXTRA ANALOGUE ADDRESSABLE
FEAOE2000 - Fyreye Extra Analogue Addressable Optical Detector Part no
LF6000-002
FEAHE2000 - Fyreye Extra Analogue Addressable Temperature
Detector Rate Of Rise
Part no
LF6000-003
FEAHHE2000 - Fyreye Extra Analogue Addressable Fixed Heat
Detector
Part no
LF6000-004
FEAOH2000 - Fyreye Extra Analogue Addressable Combined
Temperature and Optical Detector
Part no
LF6000-005
FE-CB/S - Fyreye Extra Analogue Addressable Common Base
(Shallow)
Part no
LF6000-006
FE-IB - Fyreye Extra Analogue Addressable Detector Isolator Base Part no
LF6000-007
PAGE 07 Rev 1
FYREYE EXTRA ANALOGUE ADDRESSABLE
ZT-CP3/AD - Fyreye Extra Analogue Addressable Surface
Mount Manual Call Point
Part no
LF6000-001
CP3-FMB - CP3 Call Point Flush Mount Bezel Part no
LF6000-008
CP3-CV - CP3 Call Point Cover Part no
LF6000-009
ZT-CP3/AD/WP - Fyre Extra Analogue Addressable
Weatherproof Manual Call Point (surface mount only)
Part no
LF6000-010
ZTA-LE2 Fyreye Extra Analogue
Addressable Remote Indicator (addressed the same as the detector its connected to)
Part no
LF6000-014
PAGE 08 Rev 1
FYREYE EXTRA ANALOGUE ADDRESSABLE
ZIU - Fyreye Extra Analogue Addressable Input Unit Part no
LF6000-015
ZIOU - Fyreye Extra Analogue Addressable Input / Output
Unit
Part no
LF6000-020
ZIOU/230 - Fyreye Extra Analogue Addressable Mains
Switching Input / Output Unit
Part no
LF6000-028
ZSCC - Fyreye Extra Analogue Addressable Sounder
Controller Unit (requires a 24v DC supply)
Part no
LF6000-021
ZSCC/4 - Fyreye Extra Analogue Addressable Quad
Sounder Controller Unit (requires a 24v DC supply)
Part no
LF6000-022
PAGE 09 Rev 1
FYREYE EXTRA ANALOGUE ADDRESSABLE
ZTA-CSB - Fyreye Extra Analogue
Addressable Common Sounder Base (responds to address 126, does not require its own
address)
Part no
LF6000-011
ZTA-CSFIB - Fyreye Extra
Analogue Addressable Common
Sounder / Beacon Base (responds to
address 126, does not require its own address)
Part no
LF6000-012
ZAS2/W - Fyreye Extra Analogue
Addressable Sounder Base With
White Cap (requires detector base part number
FE-CB / S for use with detector)
Part no
LF6000-023
ZAS2/R - Fyreye Extra Analogue
Addressable Sounder Base With Red
Cap (requires detector base part number FE-CB /
S for use with detector)
Part no
LF6000-024
ZASF/RI Fyreye Extra Analogue
Addressable Beacon
Part no
LF6000-025
ZTA-PSFIB - Fyreye Extra
Analogue Addressable Programma-
ble Sounder / Beacon Base (Addressable
detectors plug straight onto this unit).
Part no
LF6000-030
ZTA-PSB - Fyreye Extra Analogue
Addressable Programmable Sounder
Base (Addressable detectors plug straight onto
this unit).
Part no
LF6000-029
PAGE 10 Rev 1
FYREYE EXTRA ANALOGUE ADDRESSABLE
ZAS2/WFI - Fyreye Extra Analogue
Addressable Sounder / Beacon Base
With White Cap (requires detector base part
number FE-CB / S for use with detector)
Part no
LF6000-026
ZAS2/RFI - Fyreye Extra Analogue
Addressable Sounder / Beacon Base
with Red Cap (requires detector base part
number FE-CB / S for use with detector)
Part no
LF6000-013
ZAMT/W - Fyreye Extra Analogue
Addressable Sounder White (suitable
for indoor or outdoor use)
Part no
LF6000-027
ZAMT/R - Fyreye Extra Analogue
Addressable Sounder Red (suitable for
indoor or outdoor use)
Part no
LF6000-016
ZAMTF/R - Fyreye Extra Analogue
Addressable Sounder / Beacon Red (suitable for indoor or outdoor use)
Part no
LF6000-017
PAGE 11 Rev 1
FIRECLASS ADDRESSABLE
The Fireclass addressable panels are designed to work with the
Fireclass digital protocol.
Fireclass panels are available in a 32,64 and 240 zone option.
Networkable up to 24 panels
EN54 2/4 and CPD approved.
Up to 250 addresses per loop (Fireclass up to 125 addresses).
Comprehensive array of loop devices
4 Loop panels are housed within deep cabinets which are
suitable for 38ah batteries.
Extensive expansion I/O options.
Fireclass Lite 32 zone
(1 loop 125 devices)
Part no
LF2100-001
Fireclass 32 zone
(1 loop 250 devices)
Part no
LF2100-002
Fireclass 64
(2 loop 250 devices per loop)
Part no
LF2100-003
Fireclass 64
(4 loop 250 devices per loop)
Part no
LF2100-004
Fireclass 240
(2 loop 250 devices per loop)
Part no
LF2100-005
Fireclass 240
(4 loop 250 devices per loop)
Part no
LF2100-006
NEW
PAGE 12 Rev 1
FIRECLASS ADDRESSABLE
FC460P Photo detector Part no
LF6100-001
FC460PH Photo Heat detector Part no
LF6100-002
FC460H Heat detector Part no
LF6100-003
FC460PC Triple Sensor
(co/heat/smoke)
Part no
LF6100-004
4B Detector base Part no
LF6100-005
4B-I Detector isolator base Part no
LF6100-006
FC420CP indoor call point Part no
LF6100-007
FC421CP outdoor call point Part no
LF6100-008
801RIL Remote indicator Part no
LF6100-009
NEW
PAGE 13 Rev 1
FIRECLASS ADDRESSABLE
FC410MIM Mini input module (PCB
only)
Part no
LF6100-009
FC410CIM Contact input module
(PCB only)
Part no
LF6100-010
FC410SIO Single input output
module (PCB only)
Part no
LF6100-011
FC410MIO Multi input output
module (PCB only)
Part no
LF6100-0012
FC410RIM Relay module
(PCB only)
Part no
LF6100-013
FC410SNM Sounder output module
(PCB only)
Part no
LF6100-014
FC410QIO Quad input output
module (PCB only)
Part no
LF6100-015
FC410QRM Quad Relay module
(PCB only)
Part no
LF6100-016
FC470CV ancillary cover (required
for interfaces to mount to a 2 gang
back box)
Part no
LF6100-017
NEW
PAGE 14 Rev 1
FIRECLASS ADDRESSABLE
FC430LPSB sounder base Part no
LF6100-018
FC430LPASB Sounder beacon base Part no
LF6100-019
FC410LPSYR Stand alone red
sounder indoor
Part no
LF6100-020
FC410LPSYW Stand alone white
sounder indoor
Part no
LF6100-021
FC410LPSY Stand alone red sounder
IP65
Part no
LF6100-022
FC410LPAVR Stand alone red
sounder beacon
Part no
LF6100-023
FC410LPAVW Stand alone white
sounder beacon
Part no
LF6100-024
FC410LPAV Stand alone red
Sounder beacon IP65
Part no
LF6100-025
NEW
PAGE 15 Rev 1
DISCOVERY/VOYAGER ANALOGUE ADDRESSABLE
Discovery panel expandable up to 4 loops (500mA per loop)
Approved to EN54 parts 2 and 4.
Discovery double enclosures available to produce a 5 to 8 loop
panel.
Voyager available in 1 or 2 loop versions (500mA per loop)
Compatible with Apollo XP95 and Discovery devices.
Networkable up to 15 panels (Discovery and Voyager)
Available in 32 zone and 96 zone (Discovery only).
Powerful programming capabilities / PC configurable
Input / Output expansion (up to 15 x 8 way boards)
Discovery 1 loop Analogue
Addressable Control Panel
Part no
LF6200-001
Discovery 2 loop Analogue
Addressable Control Panel
Part no
LF6200-002
Discovery 3 loop Analogue
Addressable Control Panel
Part no
LF6200-003
Discovery 4 loop Analogue
Addressable Control Panel
Part no
LF6200-004
Voyager 1 loop Analogue
Addressable Control Panel
Part no
LF6200-009
Voyager 2 loop Analogue
Addressable Control Panel
Part no
LF6200-010
PAGE 16 Rev 1
APOLLO ANALOGUE ADDRESSABLE
55000-600 Apollo XP95Analogue
Addressable Optical Detector
Part no
LF2501-023
55000-400 Apollo XP95Analogue
Addressable Temperature Detector
Part no
LF2501-024
55000-401 Apollo XP95Analogue
Addressable High Temperature
Detector
Part no
LF2501-021
55000-885 Apollo XP95Analogue
Addressable Combined
Temperature and Optical Detector
Part no
LF2501-253
45681-210 Apollo XP95 Analogue
Addressable Common Base
Part no
LF2501-020
SEE PRICE LIST FOR MORE XP95 / DISCOVERY DEVICES
PAGE 17 Rev 1
APOLLO ANALOGUE ADDRESSABLE
55100-908 Apollo XP95 Analogue
Addressable Manual Call Point
Part no
LF2501-590
55000-841 Apollo XP95Analogue
Addressable Switch Monitor Plus
Part no
LF2501-377
55000-847 Apollo XP95Analogue
Addressable Input / Output Unit
Part no
LF2501-281
55000-875 Apollo XP95 Analogue
Addressable Mains Input / Output
Unit
Part no
LF2501-219
55000-588 Apollo XP95 Analogue
Addressable 3 way Input / Output
Unit
Part no
LF2501-383
55000-852 Apollo XP95 Analogue
Addressable Sounder Controller
Unit (requires a 24v DC supply)
Part no
LF2501-381
55000-760 Apollo XP95 Analogue
Addressable Mini Switch Monitor
Unit
Part no
LF2501-622
SEE PRICE LIST FOR MORE XP95 / DISCOVERY DEVICES
PAGE 18 Rev 1
APOLLO ANALOGUE ADDRESSABLE
45681-276 Apollo XP95 Analogue
Addressable Ancillary Sounder Base (does not require its own address)
Part no
LF2601-034
45681-277Apollo XP95 Analogue
Addressable Sounder Base (requires its
own address)
Part no
LF2601-064
45681-330 Apollo XP95 Analogue
Addressable Sounder / Beacon Base (requires its own address)
Part no
LF2601-066
45681-293 Apollo XP95 Red Cap (for use with part numbers 45681-291 and 45681-
330)
Part no
LF2601-068
45681-284 Apollo XP95 Analogue
Addressable Isolating Base
Part no
LF2501218
SEE PRICE LIST FOR MORE XP95 / DISCOVERY DEVICES
PAGE 19 Rev 1
APOLLO ANALOGUE ADDRESSABLE
55000-001 Apollo XP95Analogue
Addressable Sounder
Part no
LF2601-076
55000-005 Apollo XP95Analogue
Addressable Sounder / Beacon
Part no
LF2601-078
55000-274 Apollo XP95 Analogue
Addressable Weatherproof Sounder
Part no
LF2601-069
55000-298 Apollo XP95 Analogue
Addressable Weatherproof Sounder /
Beacon
Part no
LF2601-073
53832-70 Remote Indicator Part no
LF2500-227
PAGE 20 Rev 1
INFINITY CONVENTIONAL PANEL
The New Infinity range of panels are housed within in a modern
designed flame retardant ABS enclosure.
Compatible with the release of the new MKII Fyreye detectors.
Fully removable front cover for easy cable installation access.
Access via password removing problems with lost keys.
Available in 2,4,6 and 8 zones
4 sounder circuits ( 4,6, and 8 zone)
Sounder delay option
EN54 parts 2&4 /CPD Approved
Infinity 2 - 2 Zone Conventional Control
Panel
Part no
LF4000-001
Infinity 4 - 4 Zone Conventional Control
Panel
Part no
LF4000-002
Infinity 6 - 6 Zone Conventional Control
Panel
Part no
LF4000-003
Infinity 8 - 8 Zone Conventional Control
Panel
Part no
LF4000-004
NEW
PAGE 21 Rev 1
FYREYE MKII EXTRA CONVENTIONAL
MKII-OP Fyreye MKII optical
detector
Part no
LF5000-001
MKII-HF Fyreye MKII fixed heat
detector
Part no
LF5000-002
MKII-HR Fyreye MKII rate of rise
and fixed heat detector
Part no
LF5000-003
MKII-OH Fyreye MKII combined
smoke and heat detector
Part no
LF5000-004
MKII-CB Fyreye MKII common
diode base.
Part no
LF5000-005
NEW
PAGE 22 Rev 1
FYREYE EXTRA CONVENTIONAL
ZMT/8W White Maxitone 24v
Conventional Sounder
Part no
LF5000-006
ZMT/8R Red Maxitone 24v
Conventional Sounder
Part no
LF5000-007
ZMTF/8R Red Maxitone 24v
Conventional Sounder / Beacon
Part no
LF5000-008
ZTSR/EXD24 Flame proof siren
24v dc
Part no
LF5000-009
ZTSR/EXD230 Flame proof siren
230v ac
Part no
LF5000-010
PAGE 23 Rev 1
FYREYE EXTRA CONVENTIONAL
ZTB6B Fire Alarm Bell 6” 24v DC Part no
LF5000-011
ZTSL6/R Red 24v Xenon Flashing
Beacon
Part no
LF5000-012
ZT-RL Conventional Remote
Indicator
Part no
LF5000-014
ZT-CP3Conventional Call Point Part no
LF5000-015
ZTSL6/A Amber 24v Xenon
Flashing Beacon
Part no
LF5000-013
PAGE 24 Rev 1
CB200 CONVENTIONAL
The CB200 panel is housed within a flame resistant polycarbonate
enclosure.
Removable cable-entry grommets
User-Friendly access code
Available in 1,2,4 and 8 zones.
Non-latching zone feature
Designed to work with a wide range of manufacturers detectors
including the Fireclass and Apollo range..
Mains or 24vdc Repeaters available.
CB200 1 Zone Conventional Control
Panel
Part no
LF4100-049
CB200 2 Zone Conventional Control
Panel
Part no
LF4100-050
CB200 4 Zone Conventional Control
Panel
Part no
LF4100-051
CB200 8 Zone Conventional Control
Panel
Part no
LF4100-052
CB200 Repeater with mains supply
and charger
Part no
LF4100-053
CB200 Repeater 24vdc (1 unit can be
powered from main panel)
Part no
LF4100-054
PAGE 25 Rev 1
FIRECLASS PRECEPT EN CONVENTIONAL
The Fireclass Precept En range of panels are housed within a mild
steel enclosure.
Top knockouts for 20mm cable glands.
Display mounted controls access key switch
Available in 2,4,8,16 and 32 zones
2,4,8,16 zone modules will house up to 12ah batteries.
Wide range of expansion boards and enclosures.
Extensive configuration options
Designed to work with a wide range of manufacturers detectors
including the Fireclass and Apollo range.
Fireclass Precept EN 2 Zone
Conventional Control Panel
Part no
LF4100-001
Fireclass Precept EN 4 Zone
Conventional Control Panel
Part no
LF4100-002
Fireclass Precept EN 8 Zone
Conventional Control Panel
Part no
LF4100-003
Fireclass Precept EN 16 Zone
Conventional Control Panel
Part no
LF4100-004
Fireclass Precept EN 32 Zone
Conventional Control Panel
Part no
LF4100-005
PAGE 26 Rev 1
FIRECLASS CONVENTIONAL
601P Optical Detector Part no
LF5100-006
601PH High Performance Optical Detec-
tor
Part no
LF5100-007
601H-R Rate Of Rise Heat Detector Part no
LF5100-008
601CH CO Detector Part no
LF5100-009
601F Flame Detector Part no
LF5100-010
601H-F Heat Detector Fixed 60deg C Part no
LF5100-011
4B Detector Base Part no
LF5100-012
4B-D Conventional Diode Base Part no
LF5100-013
801RIL Remote indicator Part no
LF5100-014
Manual Call Point with 680 ohm resis-
tor c/w back box
Part no
LF2501-013
Weatherproof Manual Call Point with
680 ohm resistor c/w back box
Part no
LF2501-176
PAGE 27 Rev 1
APOLLO CONVENTIONAL
55000-317 Apollo S65 Conventional
Optical Detector
Part no
LF2501-004
55000-122 Apollo S65 Conventional
Temperature Detector A1R
Part no
LF2501-006
55000-137 Apollo S65 Conventional
High Temperature Detector CS90
Part no
LF2501-010
45681-20 Apollo S65 Conventional
Diode Common Base
Part no
LF2501-003
Conventional KAC call point with
680 ohm resistor and back box
Part no
LF2501-013
SEE PRICE LIST FOR MORE APOLLO CONVENTIONAL
DEVICES
PAGE 28 Rev 1
CONVENTIONAL
Red 24v Electronic Sounder
Shallow Base
Part no
LF2601-010
Red 24v Electronic Sounder Deep
Base
Part no
LF2601-009
Red 24v Electronic Sounder/Beacon
Shallow Base
Part no
LF2601-044
Red 24v Klaxon IP65 106dBA
sounder deep base.
Part no
LF2601-017
ZTB6B Fire Alarm Bell 6” 24v DC Part no
LF5000-011
Other sounders available please
call for prices
PAGE 29 Rev 1
CONVENTIONAL
Fireray Beam Detector 50 metres Part no
LF5100-015
24v dc Magnetic door holder Part no
LF5100-016
240v ac Magnetic door holder Part no
LF5100-017
Magnetic door holder floor bracket Part no
LF5100-018
Push button temporary alarm Part no
LF5000-019
Fire alarm safety isolator switch Part no
LF5000-020
Document box holder (useful for
storing manuals, logbook, drawings.
Part no
LF2501-588
PAGE 30 Rev 1
FIRECLASS DUO-CEL 2 WIRE FIRE ALARM PANEL
Fireclass Duo-Cel 2 wire 2 zone panel Part no
LF4200-001
Fireclass Duo-Cel 2 wire 4 zone panel Part no
LF4200-002
Fireclass Duo-Cel 2 wire 8 zone panel Part no
LF4200-003
Fulleon - Symphoni 2 wire standalone
sounder Red
Part no
LF5200-001
Fulleon - Symphoni 2 wire standalone
sounder White
Part no
LF5200-002
Fulleon - Squashni micro 2 wire
sounder base
Part no
LF5200-003
Fulleon - SQG3 2 wire sounder base Part no
LF5200-004
Fulleon - SQG3AV 2 wire sounder/
beacon base
Part no
LF5200-005
The Fireclass Duo-Cel is available in 2,4 and 8 zone versions.
Saves on installation time as detectors, call points and sounders are
wired on the same two core cable from the panel.
The Fireclass Duo-Cel panel has been designed to use the Fulleon 2
wire range of sounders (see below) and most conventional detectors.
PAGE 31 Rev 1
PREMIER EX8 GAS EXTINGUISHING
Premier EX8 Combined
extinguishing alarm panel
Part no
LF4300-001
Premier EX8 Extinguishing repeater
panel
Part no
LF4300-002
Premier EX8 Manual release call
point
Part no
LF4300-003
Premier EX8 Abort manual call point Part no
LF4300-004
The Premier EX8 is designed to BSEN12094-1:2003 & EN54 parts 2
and 4.
It has 2 “crossed zones” for co-incidence detection for the extinguishing
circuit, and 4 conventional zones for the standard fire alarm detection
(non protected areas).
The Premier EX8 is compatible with the Fyreye Extra conventional
devices (see pages 22-24).
PAGE 32 Rev 1
FIRECLASS PRESCIENT 3 GAS EXTINGUISHING
Fireclass Prescient 3 gas
extinguishing panel
Part no
LF4300-050
Fireclass Prescient 3 status indicator
Type SLU1
Part no
LF4300-051
Fireclass Prescient 3 status indicator
Type SLU2
Part no
LF4300-052
Fireclass Prescient 3 status indicator
Type SLU3
Part no
LF4300-053
KAC Extinguishing release manual
call point c/w back box and lift flap.
Part no
LF4300-055
The prescient 3 is approved to BSEN12094-1:2003, BSEN54 parts 2 and 4
and is also designed to BS7273-1:2000.
Status indicators connected via RS485 reducing cable cores.
The Fireclass Prescient 3 is compatible with the Fireclass conventional
range of devices and most other conventional devices including the Apollo
range.
Single or double knock operation
Multiple monitored and output signals.
PAGE 33 Rev 1
POWER SUPPLIES
Premier power supply 2amps
(2 x 0.625 amp outputs)
Part no
LF5300-001
Premier power supply 5amps
(2 x 2 amp outputs)
Part no
LF5300-002
The Premier power pack
EN54-4 power supply allows
the engineer to view system
status through the on board
LCD screen.
2.5 Amp power supply
unboxed
Part no
LF5300-003
5 Amp power supply unboxed Part no
LF5300-004
10 Amp power supply
unboxed
Part no
LF5300-005
15 Amp power supply
unboxed
Part no
LF5300-006
2.5 Amp power supply boxed
Dims 225 x 350 x 105 mm
Part no
LF5300-007
5 Amp power supply boxed
Dims 350 x 450 x 185 mm
Part no
LF5300-008
10 Amp power supply boxed
Dims 350 x 450 x 185 mm
Part no
LF5300-009
PAGE 34 Rev 1
FIRE TELEPHONE AND DISABLED REFUGE
CELTEL 4 way EVC panel with
handset and display
Part no
LF8000-001
CELTEL Master 8 way EVC panel
with handset and display
Part no
LF8000-002
TYPE B Hands free outstation
stainless steel flush mount
Part no
LF8000-003
TYPE B Hands free outstation
stainless steel surface mount
Part no
LF8000-004
TYPE A Fire telephone with push
door
Part no
LF8000-005
TYPE A Fire telephone with lift lock Part no
LF8000-006
Green Type B outstation flush mount Part no
LF8000-007
Green Type B outstation surface
mount
Part no
LF8000-008
Disabled persons toilet alarm kit Part no
LF8000-009
PAGE 35 Rev 1
BATTERY SETS
2.1 Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-001
3.4 Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-002
7 Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-003
12 Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-004
17 Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-005
38Ah Sealed lead acid battery set
(2 x 12v)
Part no
LF3000-006
Larger Battery Sizes Available, Also
Emergency Light Batteries Please
Call For Prices
PAGE 36 Rev 1
EMERGENCY LIGHTING
ZT-AX/X8/NM3 Non Maintained
8W Bulkhead Emergency Light
Part no
LF9000-001
ZT-AX/X8/M3 Maintained 8W
Bulkhead Emergency Light
Part no
LF9000-002
ZT-REC/1X8/NM3 Recessed Non
Maintained 8W Emergency Light
Part no
LF9000-003
ZT-REC/1X8/M3 Recessed
Maintained 8W Emergency Light
Part no
LF9000-004
ZT-EXT/1X8/M3 Maintained 8W
Emergency Exit Sign (c/w legend)
Part no
LF9000-005
directional legends must be specified at the time
of ordering)
ZT-ELD/M3/C Maintained
Hanging Emergency Exit Sign
Chrome
Part no
LF9000-006
ZT-ELD/M3/W Maintained
Hanging Emergency Exit Sign
White
Part no
LF9000-007
ZT-ELD/M3/B Maintained
Hanging Emergency Exit Sign
Brass
Part no
LF9000-008
ZT-TWS/2X20/NM3 Non
Maintained 20W Twin Emergency
Spotlight
Part no
LF9000-009
PAGE 37 Rev 1
Legacy Fire Limited
Unit 2 Tipper Industrial Estate
Park Road, Halesowen
West Midlands, B63 2RH
Email [email protected]