1dcbel
Your Home EV SuperchargerFeaturing blackout power and solar charging.
• Blackout Power: Use your EV’s battery to sail through multi-day utility grid outages
• Solar Charging: Charge your EV with the unlimited, free power of the sun
• Power Boost: One mile of range per minute of charge
• OrchestrateTM OS: Unique operating system that minimizes your energy costs and carbon footprint
• Dual Charge: Charge two EVs at once
• Easy Outdoor or Indoor Installation: Installed by a single technician
For North America
A single dcbel replaces the following equipment:
• Level 2 electric vehicle charger
• Fast DC bi-directional electric vehicle charger
• Solar inverter
• Stationary battery charger / inverter
• Smart home energy manager
2dcbel
DC Outputs
Nominal Power @400V (W) 15 200
Nominal Voltage (V) 400
Voltage Range1 (V) 150-500
Nominal Current (A) 38
Max Efficiency (%) 96.3
Voltage Ripple (%) < 2.5EV Inverter (V2H / V2G2)
Connectors CHAdeMO / CCS
DC Inputs
Nominal Voltage (V) 400
Voltage Range1 (V) 150-500
Nominal Current (A) 19
AC Outputs
Nominal Power (W) 7 600 / 15 2003
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 32 / 643
Frequency (Hz) 60 (50 capable)
Max Efficiency (%) 98.4
Power factor (%) > 99
THD (%) < 3
Grid Forming True Sine Wave
AC Level 2 EV Charger
Connector SAE J1772
Nominal Output Power (W) 9 200
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 38
1 Varies based on AC grid input.2 V2G-ready. Functionality may vary based on local utility regulations and V2G protocols. 3 Available with upcoming software update. Functionality may be limited by your EV’s capabilities.
Supporting Hardware
Autotransformer
Power (W) 7600
Voltage (Vac) 240:120Vac split-phase
Height (in / mm) 15.7 / 399
Width (in / mm) 12.6 / 320
Depth (in / mm) 6.3 / 160
DC Fast EV Charger
Connectors CHAdeMO / CCS
AC Inputs
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 64
Frequency (Hz) 60 (50 capable)
Solar Inverter
DC Inputs
Max PV Power (Wp) 20 000
Open Circuit Voltage (Voc) 600
MPPT operating range (V) 240-500
Short Circuit Current (A) 28 per MPPT
Max Current (A) 19 per MPPT
Number of MPPT Channels 2
Max Strings per MPPT 1
AC Outputs
Nominal Power (W) 15 200
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 64
Nominal Frequency (Hz) 60 (50 capable)
Max Efficiency (%) 98.4
Power factor (%) > 99
THD (%) < 3
3dcbel
AC Output (dcbelTM to Home)
Nominal Output Power (W) 15 200
Nominal Output Voltage (V) 240 Single Phase or +120/-120 Split Phase
Output Voltage Range (V) 208-254
Nominal Output Current (A) 64
Frequency (Hz) 60 (50 capable)
4 Stationary battery management available with upcoming software update.
5 A 175A breaker dedicated to the subpanel is required to leverage all of dcbel’s functionalities at full power at the same time. A 125A breaker dedicated to the subpanel can be installed, but note that the speed of EV charging may be limited during periods of peak home load consumption.
General
Dimensions
Height (in / mm) 31.5 / 800
Width (in / mm) 19.7 / 500
Depth (in / mm) 9.1 / 230
Total Weight (lbs / kg) <90 / <42
Max Component Module Weight (lbs / kg)
55 / 25
Standby Monitoring Power Consumption (W)
<30
Communication RJ45 – TCP/IP ready
Operating Temperature (°F/°C)
-40 to 104 / -40 to 40
Enclosure NEMA 3R, IP54, UL94 5VB
Certification UL 2202, 2594, 2231-1, 2231-2, 1741 SA, IEEE 1547.1, FCC Part 15 (pending)
Security Certification CC Certified (TPM 2.0 at EAL4+) & FIPS 140-2 Level 1 & 2
AC Connection: Breaker Size Recommendation
Installation with Blackout Power
DC Charger, Solar Inverter, V2H/V2G, ESS (A) (Double-pole breaker in main panel)
175 or 1255 (including subpanelhouse load)
EV AC Charger (A) (Double-pole breaker in subpanel)
50
UPS connected to wall socket (A) (Single-pole breaker in subpanel)
15
Installation without Blackout Power
DC Charger, Solar Inverter, V2H/V2G, ESS (A) (Double-pole breaker in main panel)
2 x 40
EV AC Charger (A) (Double-pole breaker in main panel)
50
Power Supply (A) (Plug into wall socket or single-pole breaker in main panel)
15
Discharging
DC Inputs
Nominal Voltage (V) 400
Voltage Range (V) 240-500
Nominal Current (A) 19
AC Outputs
Nominal Power (W) 7 600
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 32
Frequency (Hz) 60 (50 capable)
Max Efficiency (%) 98.4
Power factor (%) > 99
THD (%) < 3
Grid Forming True Sine Wave
Stationary Battery4
Communication RS485 / CAN Bus
Charging
AC Inputs
Nominal Voltage (V) 240 Single Phase or +120/-120 Split Phase
Voltage Range (V) 208-254
Nominal Current (A) 32
Frequency (Hz) 60 (50 capable)
DC Outputs
Nominal Power (W) 7 600
Nominal Voltage (V) 400
Voltage Range (V) 240-500
Nominal Current (A) 19
Max Efficiency (%) 96.3
Voltage Ripple (%) < 2.5
TempoTM (Home Current Sensor)
AC Sensor 2 CT Clamps
Communication RS485
Rated Current (A) 200
Height (in / mm) 2.9 / 74
Width (in / mm) 6.1 / 155
Depth (in / mm) 1.5 / 40
Installation Indoor only
4dcbel
Blackout Power Kit
Power Kit
Automatic Transfer Switch (ATS)
Communication RS485
Relay Rated Current (A) 200
Height (in / mm) 24 / 610
Width (in / mm) 18.5 / 470
Depth (in / mm) 6 / 152
Installation Indoor only
UPS Power Module(s)
Installation with Stationary Battery
Backup Time (Mins) 9
Height (in / mm) 4.3 / 110
Width (in / mm) 6.3 / 160
Depth (in / mm) 11.8 / 300
Installation without Stationary Battery
Backup Time (Hours) 6
Height (in / mm) 11.8 / 300
Width (in / mm) 7 / 180
Depth (in / mm) 7.4 / 190
5dcbel
dcbel Installation Single Line Diagram
dcbel Installation Wiring Diagram
EVAC SAE J1772 Type 1 EV Connector
EVDC CHAdeMO or CCS1 EV Connector
AC1 and AC2 PUC5™1, PUC5™2 and Power Supply
AC3 EVAC Grid Input
ESS and PV PV1, PV2 and Stationary Battery Power Cables
COM Stationary Battery, Tempo, Ethernet and ATS
Communication Cables
1
2
3
4
5
6
1 2 3 4 5 6
120/240 Vac Split Phase Grid Countries
120/240 Vac Split Phase Grid Countries
Other possible wiring designs may be proposed by SHIPs based on homeowners needs. Additional protective devices may be required in order to adhere to local regulations. dcbel™ offers its own PV Rapid Shutdown (PVRSS) and DC Optimizer devices (sold separately).
1 Required for residential installations that want to self-generate to power their homes in countries with a +120/-120V split phase grid unless the home has a 3 phase grid connection with 240V available or smart breaker panel with an auto-transformer.
dcbel is dedicated to solving hard scientific and engineering problems with breakthrough innovations. As such, we make incredible discoveries about our technologies every day and so it should be noted that information herein is for reference only and subject to change without notice.
© Ossiaco Inc. All rights reserved. Ossiaco, dcbel, Orchestrate, PUC5, the dcbel logo and the Ossiaco logo are trademarks or registered trademarks of Ossiaco Inc. All other trademarks mentioned herein are trademarks of their respective owners.
02-2020/V01.1/ENG. dcbel.energydcbel.energy