3
The SigMETER was discontinued in 2009 and can no longer be purchased. It revolutionized manufacturing testing when it was introduced in the 1990s, but the next-generation SigPOD brings more advanced features and greater usability, particularly in viewing and managing test records. You can’t buy a SigMETER, but you can use one to get a free offer on a sigPOD. Because Sciemetric still gets many requests for the SigMETER, we’ve created this special offer to introduce the sigPOD. The sigPOD offers many advantages over the SigMETER. No longer limited to 6-digit numeric and 2-line fluorescent displays: get an integrated or remote color touchscreen display. View data right on the system: waveforms, trending, histograms and more. Stores 5,000 to 10,000 records locally. Take advantage of this special offer and you will be able to archive all data as well. Simplified test management: limits, models, calibration and more managed right on the unit. More communications interfaces, more fieldbus options. See the comparison chart on the next page to see all the advantages of a sigPOD. Order a sigPOD by March 31, 2013 and receive the Remote Store application for long-term part history storage and review at no cost. This is a savings of $560! The Remote Store allows you to automatically archive data directly from the sigPOD onto a remote network drive. To get this free offer, provide a SigMETER serial number to your sales representative. The offer can be used on any sigPOD 1302 or 120x models. > Contact your Sciemetric representative today to take advantage of this limited time offer! 1999 2013

You can’t buy a SigMETER, but you can use one to get a ... · PDF fileThe sigPOD offers many advantages over the SigMETER. No longer limited to 6-digit numeric and 2-line fluorescent

  • Upload
    dangdat

  • View
    227

  • Download
    0

Embed Size (px)

Citation preview

Page 1: You can’t buy a SigMETER, but you can use one to get a ... · PDF fileThe sigPOD offers many advantages over the SigMETER. No longer limited to 6-digit numeric and 2-line fluorescent

The SigMETER was discontinued in 2009 and can no longer be purchased. It revolutionized manufacturing testing when it was introduced in the 1990s, but the next-generation SigPOD brings more advanced features and greater usability, particularly in viewing and managing test records.

You can’t buy a SigMETER, but you can use one to get a free offer on a sigPOD.

Because Sciemetric still gets many requests for the SigMETER, we’ve created this special offer to introduce the sigPOD.

The sigPOD offers many advantages over the SigMETER.

No longer limited to 6-digit numeric and 2-line fluorescent displays: get an integrated or remote color touchscreen display.

View data right on the system: waveforms, trending, histograms and more.

Stores 5,000 to 10,000 records locally. Take advantage of this special offer and you will be able to archive all data as well.

Simplified test management: limits, models, calibration and more managed right on the unit.

More communications interfaces, more fieldbus options.

See the comparison chart on the next page to see all the advantages of a sigPOD.

Order a sigPOD by March 31, 2013 and receive the Remote Store application for long-term part history storage and review at no cost.

This is a savings of $560!

The Remote Store allows you to automatically archive data directly from the sigPOD onto a remote network drive. To get this free offer, provide a SigMETER serial number to your sales representative. The offer can be used on any sigPOD 1302 or 120x models.

> Contact your Sciemetric representative today to take advantage of this limited time offer!

1999

2013

Page 2: You can’t buy a SigMETER, but you can use one to get a ... · PDF fileThe sigPOD offers many advantages over the SigMETER. No longer limited to 6-digit numeric and 2-line fluorescent

Display

SigMETER sigPOD 1302 sigPOD 1202/1204

Processor

Application Configuration

Storage

Operating System

Application Software

Limit setting, calibration, model selection

Information display options

6 digit Numeric Display, two line fluorescent display, LED indicators, including two bar graphs. No remote display.

SigMETER Configurator

32-bit microprocessor – Pentium 386 processor

Via the off-line configurator

Via the off-line configurator

Live readings (i.e. analog values) in the numeric display or on one of the two bar graphs.

Limited – enough for one waveform and configuration

DOS

10.4” Colour 800x600 Touchscreen Display (optional)

Option for remote display via VGA + USB

PSV (configurable for standard applications), Press, Custom Applications

• Up to 4 waveforms simultaneously• Histograms, trends• Operation result history• Calibration/diagnostics• Custom screens available with InspeXion IDE

8” Colour 800x600 Touchscreen Display (optional)

Option for remote display via VGA + USB

PSV (configurable for standard applications), Press

• Up to 4 waveforms simultaneously• Histograms, trends• Operation result history• Calibration/diagnostics

OFFER DETAILS

• A free remote store license is provided with each sigPOD ordered under this special promotion. A SigMETER serial number is required at the time of quoting to receive the free remote store application.

• The offer applies to sigPOD 1302, 1202 and 1204.

• For an order with multiple sigPODs, only one SigMETER serial number is required to get the special offer for each sigPOD purchased.

• The offer expires on March 31, 2013; orders must be received on or before this date.

• Free offer provides one sigPOD Remote Store software license per sigPOD ordered to transmit sigPOD Single Part History (SPH) records to a remote network drive. Data is stored in a flat file XML format for each part and can be viewed with the Single Part History (SPH) Viewer. Setup of the remote store, which is detailed in sigPOD user documentation, is to be done by the customer. No services are included.

• This offer cannot be combined with any other offer or discount and no substitutions are permitted.

• The cost of the remote store shown is for the standard application, in US dollars.

• Your current SigMETER application software may not be completely transferable to sigPOD PSV; however in most cases this can be resolved by writing a custom application.

DETAILED COMPARISON

Dual Core 1.66 GHz Intel Processor

Menu-based on-screen configuration: easier to get up and running quickly

On-screen, menu-driven: manage tests right on the production floor

Windows XPe

40 GB SSD5,000 to 10,000 test records, including waveforms!

Page 3: You can’t buy a SigMETER, but you can use one to get a ... · PDF fileThe sigPOD offers many advantages over the SigMETER. No longer limited to 6-digit numeric and 2-line fluorescent

Analog Inputs

Expandable

Anti-Aliasing Filter

Shunt calibration

Max sampling rate

Max sample points

Precision Excitation

Remote sense

Analog to Digital Converter

Encoder Inputs

Digital Inputs / Outputs

Environmental Rating

Dimensions

Communications ports

Fieldbus

SigMETER sigPOD 1302 sigPOD 1202/1204

1 or 2 channels±10V range 0.02% of FS±35mV range 0.07% of FS

No

1kHz 4-pole anti-aliasing filter or 20 Hz 2-pole Butterworth low pass filter

Internal relay and shunt

10 kHz

1024

5 V or 10 V (software selectable)

Yes

16 bit

0 or 1 channel, quadrature24 bit counter, 1 MHz max frequency

6 / 6

NEMA 12 when panel mounted

3” x 6” x 10.5”

Serial (2)

PROFIBUS

2 or 4 channels±10V, ±2 range 0.01% of FS±0.1 range 0.02% of FS0.033V range 0.03% of FS

Up to 24 channels with use of Model 1608

6-pole 20 kHz low-pass filter, optional 4-pole, 1 kHz low-pass filter

Internal relay and shunt

10 VDC Fixed

Yes

2 or 4 channel, quadrature or single phase32 bit counter, 10 MHz max frequency

NEMA 12 (IP 52)

250 kHz

16 bit

8 / 8

>100,000Greater accuracy by collecting much larger waveforms

2 channels ±10V, ±5V, ±1V, ranges 0.02% of FS ±200mV range 0.05% of FS

No

2-pole 20 Hz or 2 kHz low-pass filter with optional Model 132 Bridge Amplifier

With optional Model 132 Bridge Amplifier

10 VDC Fixed (5 V or 10 V switched with optional Model 132 Bridge Amplifier)

No

1 channel, quadrature or single phase32 bit counter, 10 MHz max frequency

8” x 9.4”x 5.2”

Serial, Ethernet, USB (4)

PROFINET, EtherNet/ IP, Modbus/TCP

7.5” x 9.66” x 4.2”

Serial, Ethernet, USB (2)

PROFINET, EtherNet/ IP, Modbus/TCP, PROFIBUS, DeviceNET

NEMA 12 when panel mounted

[email protected]

© 2013 Sciemetric Instruments, Inc. All brand and product names are trademarks or registered trademarks of their respective companies. Products and specifications subject to change without notice.

WWW.SCIEMETRIC.COM/SIGMETER