XX
0.2
5 G
I VX The lens arrays of Fresnel Technologies’ XX 0.25 GI VX series shown in the accompanying data sheets are in-
tended to be used in passive infrared motion detector devices. They are optimized for dual-element pyroelectric detectors; the CM types are also optimized for quad-element pyroelectric detectors with this arrangement:
The other members of the series are also optimal for quad-element pyroelectric detectors of the type:
The flanged and -NF packages are suitable for both TO-5 (tall) and TO-39 (short) pyroelectric detector cans; they must be pushed onto the pyroelectric detector far enough for the face of the detector to seat on the surface indicated in Figures 2 and 4, and the spacers shown in Figures 2 and 4 are recommended to be placed between the pyroelectric detector and the circuit board. The -SMD package variant is intended for use with surface mounted pyroelectric detectors, which need no spacer; its mounting geometry is shown in Figures 5 and 6. Please be sure to note the position within the package of the surface mounted detector you are using, as differ-ent manufacturers place the elements differently relative to the package.
Figures 9 to 23 illustrate the beam patterns for the arrays. Each lens array’s beam pattern is dependent on the alignment of the 3 Roman numerals on the lens array to the pyroelectric detector’s tab or the corresponding orientation of the surface mounted pyroelectric detector, as shown in Figures 1, 3, 7, and 8. Each data sheet in-dicates our suggested mounting alignment for each different beam pattern.
The figures postulate a dual-element or quad-element detector with a 110° acceptance angle and a mounting height of 1 meter (3 feet) for the types designed AA (Animal Alley), 1.3 meters (4 feet) for the WS (Wall Switch) types, 1 or 1.3 meters for the VB (Vertical Barrier) types, and 2.5 meters (8 feet) for the CM (Ceiling Mount) types.
It is reasonable to expect CM detection of full body motion over a diameter of 8 meters (26 feet), small hand motion over a diameter of 6.5 meters (22 feet) from a mounting height of 3 meters (10 feet); a diameter of 11 meters (36 feet) for full body motion, and 5 meters (16 feet) for small hand motion from a mounting height of 5.2 meters (17 feet), using a quad-element pyroelectric detector.
Similarly, AWV3 can be expected to cover an aisle 15 meters (45 feet) long x 1.7 meters (5.5 feet) wide from a mounting height of 5.2 meters (17 feet), 15 meters (44 feet) long from a mounting height of 6.7 meters (22 feet), 11 meters (36 feet) long from a mounting height of 8 meters (26 feet), and 10 meters (32 feet) long from a mount-ing height of 10 meters (32 feet), with a good-quality dual-element pyroelectric detector.
VB V4 can be expected to cover up to a distance of 4.6 meters (15 feet) from the unit for full-body motion, 2.7 meters (9 feet) for small hand motion with a dual-element pyro electric detector. WS V4 will cover an area 7 meters (23 feet) deep by 8 meters (26 feet) wide for full-body motion, 3.7 meters (12 feet) deep by 5 meters (16 feet) wide for small hand motion with a dual-element pyroelectric detector.
171211
f© Copyright Fresnel Technologies, Inc. 2012-17
CM 0.25 GI V1
CM 0.25 GI V2
CM 0.25 GI V3
CM 0.25 GI V4
CM 0.25 GI V5
WS AA 0.25 GI V1
WS AA 0.25 GI V2
WS VB AW 0.25 GI V3
WS VB AW 0.25 GI V4
www.fresneltech.com
AA
Lens slots that fit onto a pyroelectric detector's tab are
labeled l, ll and lll
Figure 1
XX 0.25 GI VXMounting Geometry(Spacers are required - see Figure 2)
Slots labeled l, ll and lll
SlotsRunner - next to symbol II
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2012
Ribs holdlens in place
on pyroelectric detector can
9.0 mm
SECTION A-A
2.5 mm
2.8 mm
Figure 2
XX 0.25 GI VXTO-39 (short) and TO-05 (tall) Pyroelectric Mounting Geometry
SECTION A-A
TO-39 CAN
Surface
SECTION A-A
TO-5 CAN
Surface
Ø
Spacer
11.2 mm
2.5 mm
3.6 mm
4.6 mm
Spacer1.5 mm
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2012
3.0 mm 3.9 mm
2.8 mm10.7 mm
8.7 mmØ
Figure 3
XX 0.25 GI VX-NFMounting Geometry(Spacers are required - see Figure 4)
AA
SlotsIdentifying Marks
Labled 1, ll and lll
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2014
Ribs holdlens in place
on pyroelectric detector can
Figure 4
XX 0.25 GI VX-NFTO-39 (short) and TO-05 (tall) Pyroelectric Mounting Geometry
9.0 mm
SECTION A-A
SECTION A-A
Surface
SECTION A-A
TO-5 CAN
Surface
Ø
3.6 mm
4.6 mm
Spacer1.5 mm
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2014
2.5 mm
2.8 mm 11.2 mm
3.9 mm3.2 mm
2.9 mm10.7 mm
TO-39 CAN
Spacer2.5 mm
8.7 mmØ
Figure 5
XX 0.25 GI VX-SMDMounting Geometry
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
Crush ribs hold lens in place
Sensitive elements are not in the center of the
package on all Surface Mounted
Detectors
Figure 6
XX 0.25 GI VX-SMDMounting Geometry
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
TOP VIEW
A-A
SECTION A-A
1.3mm
Plane of the pyroelectric detector's sensitive elements
9.8mm D9mm D
8.7mm
7.8mm
6mm R
2.2mm2.8mm
5.3mm
2.8mm
fresnel technologies inc. drawing and design 2016
25.5°
Figure 7
XX 0.25 GI VX-SMDMounting Geometry - Circuit Board
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
Orientation-1
Floor
Ceiling
Lens outline for reference only
Orientation-2
Floor
Ceiling
9.9 mm diameter0.1 mm offset
from pins
8.6 mm diameter0.1 mm offset
from pins
Lens outline for reference only
9.9 mm diameteroffset 0.1 mm
from pins
1.2 mm wide(2x circuit board cutouts for pins)
8.6 mm diameter0.1 mm offset
from pins
1.2 mm wide(2x circuit board cutouts for pins)
Figure 8
XX 0.25 GI VX-SMDMounting Geometry - Circuit Board
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
Orientation-3
Floor
Ceiling
Lens outline for reference only
Orientation-4
Aisleway Direction
9.9 mm diameter0.1 mm offset
from pins8.6 mm diameter
0.1 mm offset from pins
1.2 mm wide(2x circuit board cutouts for pins)
Lens outline for reference only
9.9 mm diameter0.1 mm offset
from pins8.6 mm diameter
0.1 mm offset from pins
1.2 mm wide(2x circuit board cutouts for pins)
2.4m (8ft)
0m(0ft)
4.5m (15ft)
4.5m (15FT)
0m(0ft)
CL
4.5m (15FT)
4.5m (15FT)
0m(0ft)
CL
2.25m (7.5FT)
2.25m (7.5ft)
Figure 9
CM 0.25 GI V1
CM 0.25 GI V1-NF:
Lens Array detail
Lens Array detail
CM 0.25 GI V1-SMD:
With Flange
No Flange
Surface Mounted Detector
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
SIDE VIEW:
TOP VIEW:
CM 0.25 GI V1
Lens Array detail: See Figure 7, Orientation 1
2.4m (8ft)
2.4m (7.9ft)
2.4m (7.9ft)
0m(0ft)
4.5m (15ft)
4.5m (15FT)
SIDE VIEW:
0m(0ft)
4.5m (15FT)
4.5m (15FT)
0m(0ft)
CL
2.0m (6.5ft)
2.0m (6.5ft)
CL
CM 0.25 GI V2:
CM 0.25 GI V2-NF:
Lens Array detail
Lens Array detail
Figure 10
CM 0.25 GI V2-SMD:
With Flange
No Flange
Surface Mounted Detector
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
CM 0.25 GI V2
Lens Array detail: See Figure 7, Orientation 1
TOP VIEW:
2.4m (8ft)
2.4m (7.9ft)
2.4m (7.9ft)
0m(0ft)
4.5m (15ft)
4.5m (15FT)
SIDE VIEW:
0m(0ft)
4.5m (15FT)
4.5m (15FT)
0m(0ft)
CL
2.0m (6.5ft)
2.0m (6.5ft)
CL
CM 0.25 GI V3:
CM 0.25 GI V3-NF:
Figure 11
CM 0.25 GI V3-SMD:
With Flange
No Flange
Surface Mounted Detector
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
CM 0.25 GI V3
Lens Array detail: See Figure 7, Orientation 1
Lens Array detail
Lens Array detail
Figure 12
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. 2017
2.4m (8ft)
0m(0ft)
4.5m (15ft)
4.5m (15FT)
0m(0ft)
CL
4.5m (15FT)
4.5m (15FT)
0m(0ft)
CL
2.25m (7.5FT)
2.25m (7.5ft)
3.0m(10ft)
4.5m (15FT)
drawing and design
With Flange
No Flange
Surface Mounted Detector
CM 0.25 GI V4:
CM 0.25 GI V4-NF:
Lens Array detail
Lens Array detail
CM 0.25 GI V4-SMD:
TOP VIEW:
SIDE VIEW:
CM 0.25 GI V4
Lens Array detail: See Figure 7, Orientation 1
2.4m (8ft)
0m(0ft)
4.5m (15ft)
4.5m (15FT)
0m(0ft)
CL
4.5m (15FT)
4.5m (15FT)
0m(0ft)
CL
2.25m (7.5FT)
2.25m (7.5ft)
Figure 13
CM 0.25 GI V5
CM 0.25 GI V5-NF:
Lens Array detail
Lens Array detail
CM 0.25 GI V5-SMD:
With Flange
No Flange
Surface Mounted Detector
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2017
SIDE VIEW:
TOP VIEW:
5.8m (19ft)
5.8m (19ft)
CM 0.25 GI V5
Lens Array detail: See Figure 7, Orientation 1
1.2m (4ft)
6.1m (20ft)
0m(0ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
CL180°
WS AA 0.25 GI V1:
WS AA 0.25 GI V1-NF:
Lens Array detail
Lens Array detail
Figure 14
WS AA 0.25 GI V1
With Flange
No Flange
Surface Mounted Detector
WS AA 0.25 GI V1-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
For WS (wall switch) pattern, put pyroelectric detector's tab in slot I.
Lens Array detail: See Figure 7, Orientation 1
1.2m (4ft)
6.1m (20ft)
0m(0ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
CL180°
18°
WS AA 0.25 GI V1:
WS AA 0.25 GI V1-NF:
Lens Array detail
Lens Array detail
Figure 15
With Flange
No Flange
Surface Mounted DetectorWS AA 0.25 GI V1-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS AA 0.25 GI V1For AA (animal alley) pattern, put pyroelectric detector's tab in slot III.
Lens Array detail: See Figure 8, Orientation 3
1.2m (4ft)
7.6m (25ft)
0m(0ft)
10m(32.8ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
10m(32.8ft)
CL 120°
WS AA 0.25 GI V2:
WS AA 0.25 GI V2-NF:
Lens Array detail
Lens Array detail
Figure 16
WS AA 0.25 GI V2
With Flange
No Flange
Surface Mounted Detector
WS AA 0.25 GI V2-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
For WS (wall switch) pattern, put pyroelectric detector's tab in slot III.
Lens Array detail: See Figure 7, Orientation 1
1.2m (4ft)
7.6m (25ft)
0m(0ft)
10m(32.8ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
10m(32.8ft)
CL
18°
120°
WS AA 0.25 GI V2:
WS AA 0.25 GI V2-NF:
Lens Array detail
Lens Array detail
Figure 17
WS AA 0.25 GI V2
With Flange
No Flange
Surface Mounted Detector
WS AA 0.25 GI V2-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
For AA (animal alley) pattern, put pyroelectric detector's tab in slot III.
Lens Array detail: See Figure 8, Orientation 3
1.2m (4ft)
9.1m (30ft)
0m(0ft)
10m(32.8ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
10m(32.8ft)
CL
18°
120°
WS VB AW 0.25 GI V3:
WS VB AW 0.25 GI V3-NF:
Lens Array detail
Lens Array detail
Figure 18
With Flange
No Flange
Surface Mounted Detector
WS VB AW 0.25 GI V3-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS VB AW 0.25 GI V3For WS (wall switch) pattern, put pyroelectric detector's tab in slot I or III.
Lens Array detail: See Figure 7, Orientation 1
6.7m (22ft)
6.7m (22ft)
0m(0ft)
5m(16.4ft)
5m(16.4ft)
CL
WS VB AW 0.25 GI V3:
WS VB AW 0.25 GI V3-NF:
Lens Array detail
Lens Array detail
Figure 19
With Flange
No Flange
Surface Mounted Detector
WS VB AW 0.25 GI V3-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS VB AW 0.25 GI V3
0m(0ft)
9.1m (30ft)
0m(0ft)
2.4m(8ft)
2.4m(8ft)
98°
For VB (vertical barrier) pattern, put pyroelectric detector's tab in slot II.
Lens Array detail: See Figure 7, Orientation 2
WS VB AW 0.25 GI V3:
WS VB AW 0.25 GI V3-NF:
Lens Array detail
Lens Array detail
Figure 20
With Flange
No Flange
Surface Mounted DetectorWS VB AW 0.25 GI V3-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
SIDE VIEW:
WS VB AW 0.25 GI V3
2.4m (8ft)
4.6m (15ft)
9m (30ft)
7.6m (25ft)
4.6m (15ft)
4.6m (15ft)
8m (26ft)
8m (26ft)
1.5m (5ft)
1.5m (5ft)
For AW (aisleway) pattern, put pyroelectric detector's tab in slot I or III.
Lens Array detail: See Figure 8, Orientation 4
TOP VIEW:
Aisleway direction
1.2m (4ft)
7.6m (25ft)
0m(0ft)
5m(16.2)
0m(0ft)
5m(16.4ft)
CL
18°
180°
WS VB AW 0.25 GI V4:
WS VB AW 0.25 GI V4-NF:
Lens Array detail
Lens Array detail
Figure 21
With Flange
No Flange
Surface Mounted Detector
WS VB AW 0.25 GI V4-SMD:
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS VB AW 0.25 GI V4For WS (wall switch) pattern, put pyroelectric detector's tab in slot I or III.
Lens Array detail: See Figure 7, Orientation 1
Figure 22
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS VB AW 0.25 GI V4
0m(0ft)
WS VB AW 0.25 GI V4:
WS VB AW 0.25 GI V4-NF:
Lens Array detail
Lens Array detail
With Flange
No Flange
Surface Mounted Detector
WS VB AW 0.25 GI V4-SMD:
5m(16.2)
0m(0ft)
5m(16.4ft)
CL
2.4m(8ft)
2.4m(8ft)
For VB (vertical barrier) pattern, put pyroelectric detector's tab in slot II.
Lens Array detail: See Figure 7, Orientation 2
Crush ribs
Figure 23
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146fresnel technologies inc. drawing and design 2016
TOP VIEW:
SIDE VIEW:
WS VB AW 0.25 GI V4
2.4m (8ft)
4.6m (15ft)
8m (27ft)
CL 1m (3ft)
1m (3ft)
WS VB AW 0.25 GI V4:
WS VB AW 0.25 GI V4-NF:
Lens Array detail
Lens Array detail
With Flange
No Flange
Surface Mounted DetectorWS VB AW 0.25 GI V4-SMD:
5m(16.2)
0m(0ft) 5m
(16.4ft)
For AW (aisleway) pattern, put pyroelectric detector's tab in slot I or III.
Lens Array detail: See Figure 8, Orientation 4
Aisleway direction