Xplorer 1-2 Loop Analogue Xplorer 1-2 Loop Analogue Addressable Control PanelsAddressable Control Panels
• From 1-2 loops
• EN54 2 & 4 Compliance
• Fully compatible with all Apollo XP95 and Xplorer devices
• Extensive threshold-change options by 7-day, day-night programme
• Programmable loop sounder capability
• Easy configuration – Default loop outputs to “on” in fire option
• Optional Windows-based, full upload/download PC software package
Xplorer 1-2 Loop Analogue Xplorer 1-2 Loop Analogue Addressable Control PanelsAddressable Control Panels
• 500mA output per loop with highly stable voltage platform, even under mains-failed conditions
• Day/Night delay of alarm and cause/effect
outputs
• 4 Inbuilt Software Delay Timers
• Automatic recognition of Apollo and
Control Equipment outstations
• User friendly controls and a clear,
unambiguous screen
• Complies with EMC and LVD Directives
BREAK GLASS
F IRE
PRES S HERE
I SOLATOR
BREAK GLASSPRES S HERE
F IRE
I SOLATOR
F I RE
PRES S HERE
BREAK GLASS
PRES S HERE
BREAK GLASS
F I REA1445
A1445A1444/ 7
A1445
APOLLO
A1446
A1444
A1445
TRANSLATOR BARRIER
BARRIER
Xplorer Panel HardwareXplorer Panel Hardware
Up to 31 8-way panel enhancement boards may be added.
Two types are available:
1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs
Up to 31 8-way panel enhancement boards may be added.
Two types are available:
1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs
Up to 14 fully functional repeater panels may be connected via RS485 cable.
Up to 14 fully functional repeater panels may be connected via RS485 cable.The panel may be programmed
using the “on board” controls and/or Windows PC package.
The panel may be programmed using the “on board” controls and/or Windows PC package.
XP95 and Xplorer high capacity loops fully supported by Excel based design package
XP95 and Xplorer high capacity loops fully supported by Excel based design package
Mechanical AssemblyMechanical Assembly
Motherboard and power supply located on a
removable chassis to assist cabinet installation.
Motherboard and power supply located on a
removable chassis to assist cabinet installation.
Zonal LEDs and optional printer are
located on the display board.
Zonal LEDs and optional printer are
located on the display board.
Motherboard holds up to 2 loop cards
Motherboard holds up to 2 loop cards
Space for internal 12Ah battery set.
Space for internal 12Ah battery set.
Power Supply.Power Supply.
Display assembly
located on the removable door.
Display assembly
located on the removable door.
Cabinet OptionsCabinet Options
For details of panel dimensions
see Application Guide.
For details of panel dimensions
see Application Guide.
Surface Cabinets
Cabinet colour reference is: RAL 7035 textured (Light Grey)
All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint.
Semi-Flush Cabinets (Illustrated)
The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall.
It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet.
Fully Flush Cabinet
Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted.This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming).
Surface Cabinets
Cabinet colour reference is: RAL 7035 textured (Light Grey)
All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint.
Semi-Flush Cabinets (Illustrated)
The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall.
It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet.
Fully Flush Cabinet
Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted.This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming).
User displayUser display
The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable
text description.
The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable
text description.
System LED indications are
provided in addition to the LCD display.
System LED indications are
provided in addition to the LCD display.
The text descriptions give the user clear, easy-to use functional controls.
The text descriptions give the user clear, easy-to use functional controls.
The engineer accesses panel configuration functions using the numerical designations. The menu structure
on the LCD display guides the engineer through the different set-up facilities.
The engineer accesses panel configuration functions using the numerical designations. The menu structure
on the LCD display guides the engineer through the different set-up facilities.
6
5
4
3
2
1
0 1
P O W E RD E LAY O N
D IS A B LE M E N TG E N E R A L
B U ZZE RS ILE N C ED
M A IN TE N A N C EFIR E
S YS TE MFA U LT
G E N E R A L
A LE RT
S U P P LY O N
FA U LTTE S T
M E S S A G E SA LA R M FA U LT/D IS A B LE M E N T
M O R E
ZO N E S TATU SFIR E FAU LT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S ILE N C E /
M E N U U PA C C E S S M E N U
A LA R M S
D IS P LAY
A LA R M S
B U ZZE R
D E LAY
M E S S A G E S
R E S E T
R E S O U N DTE S T
TE S T
S ILE N C E
O V E R R ID EE VA C U ATE
S C R O LL
M E N U D O W N E N TE R
A C C E S S C O N TR O LS
E S C A P E
LCD DisplayLCD Display
The device types which may be indicated are as follows:
SOU - Loop sounder/sounder circuit controller
O/S - Input/Output deviceION - Ionisation smoke sensorMON - Monitor (zone monitor, control
monitor) OPT - Optical smoke sensor HEAT
- Heat sensorBGU - Call point or call point monitor
The device types which may be indicated are as follows:
SOU - Loop sounder/sounder circuit controller
O/S - Input/Output deviceION - Ionisation smoke sensorMON - Monitor (zone monitor, control
monitor) OPT - Optical smoke sensor HEAT
- Heat sensorBGU - Call point or call point monitor
PrinterPrinter
Hinged access to allow easy ribbon
change.
Hinged access to allow easy ribbon
change.
This good quality printer uses a reliable Epson
mechanism.
This good quality printer uses a reliable Epson
mechanism.
Designed for easy replacement of the paper roll
onto the carrier.
Designed for easy replacement of the paper roll
onto the carrier.
This button advances the
paper.
This button advances the
paper.
Open access to feed paper
through mechanism.
Open access to feed paper
through mechanism.
Engineer’s printer test button.
Engineer’s printer test button.
A1535 8 Way Relay Board A1535 8 Way Relay Board
RS485 comms from panel
motherboard.
RS485 comms from panel
motherboard.
8 inputs may be normally open or
normally closed and will register as fire or non-fire on the panel as configured. Inputs
are fully programmable via the
panel or PC cause/effect.
8 inputs may be normally open or
normally closed and will register as fire or non-fire on the panel as configured. Inputs
are fully programmable via the
panel or PC cause/effect.
24V DC power.24V DC power.
8 x 1Amp changeover relay
outputs may be fully programmed via the
panel or PC cause/effect programme.
8 x 1Amp changeover relay
outputs may be fully programmed via the
panel or PC cause/effect programme.
Engineer’s DIL switches to set board address, enable O/C
or S/C inputs and disable
inputs/outputs.
Engineer’s DIL switches to set board address, enable O/C
or S/C inputs and disable
inputs/outputs.
Engineer’s links to disable functions
for set-up or maintenance
purposes.
Engineer’s links to disable functions
for set-up or maintenance
purposes.
A1536 8 Way Alarm BoardA1536 8 Way Alarm Board
Engineer’s buzzer disable link for set-up or maintenance
purposes.
Engineer’s buzzer disable link for set-up or maintenance
purposes.
8 x 1Amp two-stage alarm
outputs may be fully programmed via the panel or PC cause/effect.
8 x 1Amp two-stage alarm
outputs may be fully programmed via the panel or PC cause/effect.
Engineer’s DIL switches to isolate
alarm outputs individually.
Engineer’s DIL switches to isolate
alarm outputs individually.
8 normally open inputs which will register as fire or
non-fire on the panel as
configured. Inputs are fully programmable via panel or PC
cause/effect.
8 normally open inputs which will register as fire or
non-fire on the panel as
configured. Inputs are fully programmable via panel or PC
cause/effect.
24V DC power.24V DC power.
Test alarms when switched
to 0V.
Test alarms when switched
to 0V.
Alarm Fault LEDs.
Alarm Fault LEDs.
RS485 comms from panel
motherboard.
RS485 comms from panel
motherboard.
Engineer’s DIL switches to set board address, disable
inputs and outputs, test LEDs and test alarms.
Engineer’s DIL switches to set board address, disable
inputs and outputs, test LEDs and test alarms.
Extensive User’s MenuExtensive User’s Menu
User Functions•Time/Date•Delay
•Delay Enable/Disable•Day/Night Modes
•Enable Day/Night/Auto/Off•Enable/Disable
•Devices•Zones•Printer•Sounders
•View•View Event Log•View Suppressed Events
•Test•Point Walk Test•Alarm Walk Test
•Print•Clear Print Queue•Print Event Log•Print Disablements
User Functions•Time/Date•Delay
•Delay Enable/Disable•Day/Night Modes
•Enable Day/Night/Auto/Off•Enable/Disable
•Devices•Zones•Printer•Sounders
•View•View Event Log•View Suppressed Events
•Test•Point Walk Test•Alarm Walk Test
•Print•Clear Print Queue•Print Event Log•Print Disablements
User function to operate one man device test and alarm audibility test.
User function to operate one man device test and alarm audibility test.
User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings).
User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings).
User function to read the output delay and to enable or disable its operation.
User function to read the output delay and to enable or disable its operation.
User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders.
User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders.
Overview of the Engineer’s MenuOverview of the Engineer’s Menu
1. PANEL SETUP1. LOOP SETUP
1. Loop Configuration
1. Loop Contents1. View Loop Contents
2. Print Loop Contents
1. Reconfigure Loop
2. Device Sensitivity1. Fire
2. Alert
2. Zone Allocation
1. Edit Device Zones
2. Print Device Zones
3. View Device Zones
1. PANEL SETUP1. LOOP SETUP
1. Loop Configuration
1. Loop Contents1. View Loop Contents
2. Print Loop Contents
1. Reconfigure Loop
2. Device Sensitivity1. Fire
2. Alert
2. Zone Allocation
1. Edit Device Zones
2. Print Device Zones
3. View Device Zones
3. Loop Cause Effect1. Device Group Allocation
1. Edit Device Groups2. Print Device Groups3. View Device Groups
2. Loop Output C/E3. Print Loop O/P C/E
2. I/O SETUP1. Remote Evacuate Mode
2. TEXT EDIT1. EDIT COMPANY NAME2. EDIT Device TEXT
3. Loop Cause Effect1. Device Group Allocation
1. Edit Device Groups2. Print Device Groups3. View Device Groups
2. Loop Output C/E3. Print Loop O/P C/E
2. I/O SETUP1. Remote Evacuate Mode
2. TEXT EDIT1. EDIT COMPANY NAME2. EDIT Device TEXT
Windows-based PC ProgrammingWindows-based PC Programming
Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.
Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.
RepeaterRepeater
The backlit LCD display gives information of
loop, device and zone number,
device type and event condition, together with a user-definable
text description.
The backlit LCD display gives information of
loop, device and zone number,
device type and event condition, together with a user-definable
text description.
System LED indications are
provided in addition to the LCD display.
System LED indications are
provided in addition to the LCD display.
The text descriptions give
the user clear, easy-to use functional controls.
The text descriptions give
the user clear, easy-to use functional controls.
The repeater panels are
available with local power supply,
printer and zone LED’s if required
The repeater panels are
available with local power supply,
printer and zone LED’s if required
XP95 Test ToolXP95 Test Tool
The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems.
Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual
devices around the circuit.
The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems.
Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual
devices around the circuit.
Alpha-numeric LCD display.
Alpha-numeric LCD display.
Engineer’s keypad.
Engineer’s keypad.
On/off switch and LED indication.
On/off switch and LED indication.
Battery charger socket.
Battery charger socket.
Sockets for flying leads to connect to loop and/or
individual XP95 devices.
Sockets for flying leads to connect to loop and/or
individual XP95 devices.