Page 2: XPANDAcell Product Solution Presentation R3.3 2017

• RPT-9000 solves coverage problem• Repeats CDMA/GSM signals from a cell site to

the target location, providing local coverage.• Enables the Operator to:

– Firm up coverage in fringe, low lying and limited reception areas

– Selectively extend coverage– Provide coverage where the cost of a base station

is not justifiable

What it does

Page 3: XPANDAcell Product Solution Presentation R3.3 2017

RPT-9000 Hill Application

Page 4: XPANDAcell Product Solution Presentation R3.3 2017

RPT-9000 Valley Application

Page 5: XPANDAcell Product Solution Presentation R3.3 2017

RPT-9000 Underground Application

Page 6: XPANDAcell Product Solution Presentation R3.3 2017

RPT-9000 Tunnel Application

Page 7: XPANDAcell Product Solution Presentation R3.3 2017

• RPT-9000: RF Cellular Repeater – Overall system gain - 95 dB for both uplink and downlink– Low Power Requirement with 90-260 VAC or 24 VDC @ 50W– Carrier grade, manufactured in North America, 2 Year Warranty

• RPT-9000 Hybrid: RF over Fiber Cellular Repeater– Specifications as above– Master/Slave units operate over Single Mode Fiber with Simplex Green APC Connector

• IDEN-9000: IDEN RF Cellular Repeater – Specifications as above– For use with Nextel or Motorola iDEN systems

• IDRPT-9000: Indoor/Outdoor RF Cellular Repeater– Overall system gain - 80 dB for both uplink and downlink– Advanced GUI for programming, monitoring with Email alert capability

• PA-DB: Dual Band Pre Amplifier– For additional gain between donor antenna and cellular repeater– Also used as Inline Amplifier for additional signal gain on long cable runs to area fill antenna

Products

Page 8: XPANDAcell Product Solution Presentation R3.3 2017

• 800 MHz (iDEN): Uplink of 806–821MHz and Downlink of 851–866MHz– 800 MHz systems are available as non FCC and IC certified

• 850 MHz (CLR): Uplink of 869–894MHz and Downlink of 824–849MHz– 850 MHz systems are FCC and IC certified

• 900 MHz (E-GSM): Uplink of 890–915MHz and Downlink of 935–960MHz– 900 MHz systems are available as non FCC and IC certified

• 1700 MHz (AWS): Uplink of 1710–1755MHz and Downlink of 2110–2155MHz– 1700 MHz systems are available as non FCC and IC certified

• 1800 MHz (DCS): Uplink of 1710–1785MHz and Downlink of 1805–1880MHz– 1800 MHz systems are available as non FCC and IC certified

• 1900 MHz (PCS): Uplink of 1850–1910MHz and Downlink of 1930–1990MHz– 1900 MHz systems are FCC and IC certified

• 2100 MHz (IMT): Uplink of 1920-1980MHz and Downlink of 2110–2170MHz– 2100 MHz systems are available as non FCC and IC certified

Frequency Band Coverage

Page 9: XPANDAcell Product Solution Presentation R3.3 2017

• Accommodates low CDMA/GSM signal levels• Multiple CDMA/GSM channels simultaneously• Boost Analog and Digital signals simultaneously• Built in RSSI (receive signal strength indicator) for antenna alignment• Receive sensitivity -110dBm• Low power consumption• Fully FCC and IC Certified• Signal gain Uplink 95dBm with manual adjustment• Signal gain Downlink 95dBm with manual adjustment• No simultaneous user limitations• Transparent to voice, data or video features from network• Customize performance to clients specifications• Highly reliable product backed by a Two Year Warranty

Key Features

Page 10: XPANDAcell Product Solution Presentation R3.3 2017

Profile Analysis Graph

Example of Profile analysis to determine clearance at given donor tower height• BTS Tower at left is at 100 m above ground level• Top profile based on 90 m Donor tower height at right – 89.1 m clearance at 15 Km• Bottom profile based on 100 m Donor tower height at right – 92.6 m clearance at 15

Km

Page 11: XPANDAcell Product Solution Presentation R3.3 2017

Predictive Donor Side Coverage

Example of Predictive Coverage to determine clearance at donor tower height• BTS Tower at right is at 60 m above ground level• Yellow shaded area provides signal coverage toward RPT tower• Donor antenna at 100 m above ground level

Page 12: XPANDAcell Product Solution Presentation R3.3 2017

Predictive Area Fill Coverage

Example of Area Fill Coverage to determine coverage at desired location• RPT Tower at bottom has line of site to Camp Office area• Blue shaded area provides signal coverage to the north• Area fill antenna is at 10 m above ground level

Page 13: XPANDAcell Product Solution Presentation R3.3 2017

• Western Canada Sand Mining Plant 47 Km from nearest cell tower

• Remote area - no coverage at ground level• Need for cell service to facilitate better

communications in Office Trailers, Maintenance Shop and common areas

• Company mandate to improve morale so workers are able to stay in touch with their families during off hours.

Case Study – Single Repeater Link

Page 14: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Example of Single Repeater Link providing coverage to Office Trailers and Camp• 850 MHz Cell Tower is located 47 Km to the east of the Mining site• No cell coverage at ground level due to tree coverage and hills in between• Line of site on top of silos at 30 m above ground level

Page 15: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Example of RPT-9000 Repeater used to extend cellular coverage• Donor antenna at 30 m above ground captures cell signal from BTS Tower• Repeater installed at mid point between both antennas, use of 7/8” Heliax cables• Area Fill antenna at 15 m height facing north, shaded area in blue• Office Trailers, Maintenance Shop and Camp locations have coverage at ground level

Page 16: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Page 17: XPANDAcell Product Solution Presentation R3.3 2017

• Middle East Cement Plant with close proximity to cell tower

• No coverage along 4 Km road or on other side of large hill

• GSM 900 signal available at start of road• Use of Master/Slave Hybrid Fibre Repeater to

extend signal to far side of hill near Crusher and Quarry Workshop buildings

• Additional Repeater used for signal along road

Case Study – Hybrid Repeater Link

Page 18: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Hybrid Repeater Link

Example of GSM 900 BTS at Main Cement Plant location• Current coverage from 30 m tower at a distance of 4 Km shown in green• Ridge prohibits cell signal from reaching Crusher and Quarry buildings shown in blue• No coverage along road shown in yellow including Trailers and Explosive Stores area• Single-mode fibre being run alongside road to extend data network

Page 19: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Hybrid Repeater Link

Example of Master/Slave Fibre Hybrid Repeater used to extend cellular coverage• Master unit at start of road connected to a single strand of single-mode fibre• Slave unit at end of road on 12 m tower with antennas covering rear areas• Crusher and Quarry buildings coverage from far left to straight ahead shown in blue• Back side of service road off to the right and around the corner also shown in blue

Page 20: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Hybrid Repeater Link

Additional RF Repeater used to extend cellular coverage along road• RPT2 unit installed on top of powerhouse building at start of road • Used 5 dBi low gain yagi antenna for donor signal from BTS• Coverage from 33° area fill panel antenna shown in yellow• Cell signal now covers the road up the hill, trailers and explosive store area

Page 21: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Hybrid Repeater Link

Page 22: XPANDAcell Product Solution Presentation R3.3 2017

• Western Africa Game Reserve over 50 Km from nearest cell tower

• No coverage at Farmhouse and Lodge due to being in a valley with no Line of Site

• Standard High Speed Internet not available• Satellite Internet option slow and costly• GSM 900 and 1800 signal available on hill• Extended LTE signal to provide voice and data

Case Study – Single Repeater Link

Page 23: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Example of 56 km Single Repeater Link proving coverage to Lodge and Farmhouse• BTS Tower at upper left at 50 m above ground level• Yellow shaded area provides signal coverage toward RPT tower• Donor antenna at 10 m above ground level

Page 24: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Example of Single Repeater Link providing coverage to Lodge and Farmhouse• RPT Tower at bottom left has line of site to Farmhouse and Lodge• Blue shaded area provides signal coverage to 5 Km area• Area fill antenna is at 48 m above ground level

Page 25: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Single Repeater Link

Page 26: XPANDAcell Product Solution Presentation R3.3 2017

• Central Mexico mining operation over 60 Km from nearest cell tower

• No coverage at main office and ATMs due to being in a valley with no Line of Site

• Critical to have ATM connectivity for cash withdrawal in order to avoid work stoppage

• 850 and 1900 MHz signal available on hill• Both frequencies extended for redundancy

Case Study – Dual Repeater Link

Page 27: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Dual Repeater Link

Example of 65 Km Dual Repeater Link proving coverage to main office and ATMs• BTS yellow shaded area provides signal coverage toward RPT1• RPT1 blue shaded area provides signal coverage toward RPT2• RPT2 red shaded area provides signal coverage into valley

Page 28: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Dual Repeater Link

Example of first Repeater Link proving coverage to RPT1 location• BTS Tower at left is 52 m above ground level• Yellow shaded area provides signal toward RPT1 location at 35 Km• Donor antenna at 10 m above ground level

Page 29: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Dual Repeater Link

Example of second Repeater Link proving coverage to RPT2 location• RPT1 at lower left has line of site to RPT2 location• Blue shaded area provides signal toward RPT2 at 30 Km• Area fill antenna is at 10 m above ground level

Page 30: XPANDAcell Product Solution Presentation R3.3 2017

Case Study – Dual Repeater Link

Example of second repeater proving coverage down into valley• RPT2 Tower has line of site to office, ATMs and surrounding area• Red shaded area provides signal coverage to 6 Km• Area fill antenna is at 60 m above ground level

Page 31: XPANDAcell Product Solution Presentation R3.3 2017

Thank you!

   Office: +1 201-227-8969Mobile: +1 551-486-5877WhatsApp: +1 551-486-5877

50 E. Palisade Avenue Fax: +1 201-227-8965Suite 410 Skype: gglasgall Englewood, NJ 07631 Email: [email protected]

[email protected]

Gary GlasgallRegional Director