LINE INTERACTIVE UPS500VA ~ 3000VA (1/1)

S O H O &I . T G r a d e U P S

XL SERIESDeutsche Power

Page 2: XL SERIES - Delta Technologies

XL Plus wide input range 140~300VAC for 500/1000VAand 162~290VAC for 2000VA make it suitable to use inthe areas were voltages fluctuation is serious problem.The UPS automatically Buck & Boost as per inputfeedback.

XL Series, a Line-Interactive UPS is designed for user’srequired short backup with high reliability, durabilityand economical solution. Ideally for SOHO applicationsand many other applications of similar types.

TechnologyXL Plus uses line interactive technology to produce abasic level of protection. This topology includes atransformer in series between the utility power sourceand the load, enabling the UPS to “ interact” with themains.

Wide Input Voltage Range AVR with Buck & Boost

Compact DesignXL Plus compact design makes this UPS different fromother similar Products.Its reduced dimensions is easilyintegrated into offices environment and low spaceareas.

Cold StartXL Plus is empowered with cold start function whichenable the UPS to start directly on its batteries withoutproviding the mains supply.

Off Mode ChargingXL Plus has the ability to do off mode charging whichmeans UPS can be insert for charging while poweringoff the on/off button. This feature provide the leverageto charge the UPS in non working hours while keepingthe load off.

Remote ManagementXL Plus status information can be accessed securelyfrom any computer on your IP-Based network. UPShistory log, input /output voltages,input/output frequency, battery capacity , faults andmany others feature can be view remotely.

LCDXL Plus has LCD in its front panel for easily viewing ofdifferent features directly from the UPS LCD. This LCDdisplays input /output voltages, input/outputfrequency, battery capacity , faults and many othersfeatures can be viewed.

ApplicationWork StationsComputer PeripheralsPoint of Sale EquipmentHubs, Routers

StandardsSecurity: C H 0 0 5 4 1 3 2 - 2 0 0 0 ,Conductive Disturbance: GB9254 1998/EN55022

CLASS BVideo Frequency Disturbance: GB9254 1998/

EN55022 CLASS A

XL Plus Series (500VA~3000VA)

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)LINE INTERACTIVE UPS

Page 3: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATION FOR XL-PLUS SERIES

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

LINE INTERACTIVE UPS

Rating

VA/Watt

Phase

Voltage Range (Buck & Boost AVR)

Frequency Range

Output Voltage

AC voltage Regulation

(Batt. Mode)

Frequency Range

(Batt. Mode)

Transfer Time

Waveform (Batt. Mode)

Battery Type & Number

Typical Recharge Time

Full Protection

LCD Display

Dimension

Net Weight (kgs)

Humidity

Noise Level

110/120 VAC or 220/230/240 VAC81-145 VAC / 162-290 VAC

60/50 Hz (Auto sens ing)

110/120 VAC or 220/230/240 VAC

Typ ic le 2 -6 msS imulated S inewave

4-6 hours recover to 90% capac i ty

Surge , over load , d i scharge and overcharge protect ion

0-90% RH @ 0-40 C (Non-condens ing)Less then 40d b

DP Electronics e.K(Deutsche Power Co. Limited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without prior notes.

MODEL

INPUT

OUTPUT

BATTERY

PROTECTION

XL-Plus 650650/390

XL-Plus 10001000/600

XL-Plus 20002000/1200

XL-Plus 30003000/1800

INDICATORS

PHYSICAL

ENVIRONMENT

MANAGEMENTOptional USB/RS-232 Port

12V/7Ah x 1 12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 4

AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage Overload, Fault, and Low Battery

287x100x142 350 x 146 x 160 495 x 150 x 250397 x 146 x 20524.84.25 8.9 11.5

Support Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC

± 10%

60 Hz or 50 Hz ± 1Hz

XL-Plus 500500/300

12V/7Ah x 1

287x100x1424.25

Page 4: XL SERIES - Delta Technologies

SOLO INVERTER600VA ~ 2KVA (1/1)

D o m e s t i c &I . T L o a d s

SOLO SERIES

Page 5: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATIONMODEL

RANGE

INPUT

OUTPUT

Solo 1000

Single Phase In & Single Phase Out220V/230/240±25%

50Hz±5%

Step Sine Wave220V/230V/240±10%

50Hz±1% (Battery Mode)<10msecUniversal

12VDC 24VDC10A or 20A

AC mode, Battery mode, Load Level, Battery Level, Input Voltage, Output Voltage, Over Load, Fault & Low Battery

289x290x127DIMENSION

Solo 2000

1000VA 2000VA

PhaseVoltageFrequency

Wave fromVoltageFrequencyTransfer TimeSockets

VoltageCharging Current

LCD

DxWxH(mm)

BATTERY

DISPLAY

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

SOLO Series (600VA~2KVA) Inverter for Domestic & IT LoadsYour Household Power Guardian

FeaturesSelectable input voltage range for homeappliances or personal computers

12VDC or 24VDC available

Selectable charging current : 10A or 20A

Auto restart while AC is recovering

Overload and short circuit protection

Cold start function

Generators & Computer-related devices compatible

Applications

DOMESTIC INVERTER

Tube Light

TV

Computer

Fan

Stereo

PABX

Router/Switch

Deutsche Power Solo Series Inverter system is for home andoffices appliances. Its selectable wide and narrow inputvoltage switch features flexibility for users . It is perfect to connecte i t h e r d o m est i c a p p l i a n c es o r c o m p u te r- re l a teddevices. Its a green substitution for generator without air pollution.

Solo 600

600VA

Page 6: XL SERIES - Delta Technologies

LINE INTERACTIVE PURE SINE WAVE UPS1KVA ~ 10KVA (1/1)

M i s s i o n C r i t i c a l &I . T & D o m e s t i c U P S

ELENTRA SERIES

(Extended & Short Autonomy Version).

Page 7: XL SERIES - Delta Technologies

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

Single Solution for All Domestic and IT Applications(Standard & Extended autonomy with sinewave)

ELENTRA Series is a unique one with respect to its featuresand standards. A Line-Interactive UPS with Sine Wave outputand able to run on extended autonomy makes this seriesdistinct from others. ELENTRA Series has the ability to workwith all kind of loads from domestic appliances to brandedServers without interruption.

ELENTRA Series uses line interactive technology to prodivea basic level of protection. This topology includes atransformer in series between the utility power source andthe load, enabling the UPS to “interact” with the mains.

Fast Battery RechargeELENTRA Series has the ability to enhance battery chargingamperes from 5A~20A through software the maximumrecharge time for depleted is 8 hours, no matter how manybattery packs are installed on a UPS.

Extended Runtime CapabilityELENTRA Series coms with standard (internal battery) and toprotect critical devices through extended blackouts, theELENTRA Series utilizes external battery pack that can bedaisy-chained in unlimited quantities to provide a virtualunlimited amount of battery run time.

Sinewave OutputELENTRA Series is a line interactive UPS which provides puresinewave at the output.Due to its sinewave output high criticalserver and other sophisticated equipments can be connectedwithout any fear.

LCDELENTRA Series has LCD in its front panel for easily viewingof different feature directely from the UPS LCD. This LCDdisplays input /output voltages, input/output frequency, batterycapacity , faults and many others feature can be view.

ELENTRA Series (IkVA~8kVA)

ApplicationDomestic Applications, Work Stations, Servers, MotorizedLoad, Hubs, Routers, Network stations, Gateways, PABX

StandardsSecurity : CH0054132-2000,Conductive Disturbance: GB9254 1998/EN55022 CLASS BVideo Frequency Disturbance: GB9254 1998/EN55022 CLASS A

LINE INTERACTIVE SINE WAVE UPS

Technology

Page 8: XL SERIES - Delta Technologies

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)LINE INTERACTIVE SINE WAVE UPS

Green Mode Without Green ModeCapacity1000VA1500VA2000VA3000VA5000VA6000VA8000VA

<1mA<1mA

<0.5mA<0.5mA<0.5mA<0.5mA<0.5mA

2.5A/12VDC2.9A/12VDC1.9A/24VDC2.6A/48VDC2.3A/48VDC2.3A/48VDC2.3A/48VDC

Solar Charger OptionalRating voltage 12V / 24V / 36V / 48V

12V model : 12 ~ 21Vdc24V model : 24 ~ 42Vdc36V model : 36 ~ 63Vdc48V model : 48 ~ 84Vdc

DC Input Range

Charging Method

Charging Voltage

Power Rating

Protection

Constant voltage with current limiting by PWM control12V model : 13.5Vdc24V model : 27.4Vdc36V model : 40.5Vdc48V model : 54.0Vdc

12V model : 500W (13.5Vdc @ 37A)24V model : 1000W (27.0Vdc @ 37A)36V model : 1000W (40.5Vdc @ 25A)

48V model : 1000W (54.0Vdc @ 18.5A)DC input polarity protection, DC input short circuit protection

( when battery is connected), DC output over current protection

Solar Array

DC InputLoads

DC Input / Output

Battery

AC Input

Utility

Connection concept:Elentra Series are equipped with GREEN MODE factor. The UPScan be used with PV (Solar) by converting it into GREEN MODEfunction. The GREEN MODE UPS is also equipped with chargecontroller & convert into almost 0Amp. no load current forbetter efficiency. The details of elentra in green mode functionand solar charge controller are as follows.

Green Mode with outstanding performance & reliability.

Page 9: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATION FOR ELENTRA SERIES

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

MODEL EN01 EN1.5 EN02 EN05 EN06 EN08EN031000/600 1500/800 2000/1100 3000/1800 5000/3000 6000/3500 8000/4000RatingVA/W

INPUTNominal VoltageInput FrequencyEfficiencyNoise FilteringVoltage RangeAVR Range

Surge ProtectionOUTPUTOutput VoltageVoltage WaveformCrest FactorOutput FrequencyRegulation (Nominal)Transfer timeBATTERYVDC

Charging method

GENERALProtection

CommunicationENVIRONMENTOperatingTemperature.Transit/storageTemp.Relative HumidityOperating Altitude

200V/220V/230V/240V Selectable47Hz ~ 65Hz, 50/60Hz auto-sensing

97%Full time EMI/RFI filtering

140~310VEnhanced Buck: +28% of selected nominal voltage ,Buck mode: +10% of selected nominal voltage,Boost mode: -10% of selected nominal voltage ,Enhanced Boost: -25% of selected nominal voltage.

1000VA / 1500VA :220 Joules 1600VA ~ 4000VA:440 Joules

200V/220V/230V/240V SelectablePure Sine wave

3:1Auto Select for 50/60Hz, 47Hz ~ 55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal

±10% typical of nominal voltage1ms typical

Smart pulse charging with two charging modes?Quick charging mode:14V maximum.Trickle charging mode:13.5V (adjustable with the remote set-up software)

Over current protection & Over charging voltage protection (SCR control). Thermal protection (CPU control)When temperature inside the unit is over 45C, charger will stop charging for 2 minutes followed by

2 minutes charging. The cycle will be repeated until the temperature is lower than 44C.RJ45 (Surge protection), DB9, SNMP (external type)

Up to 1500 meters:0 to 40 (32 to 104 )

-15 to 55 (5 to 131 )

5 - 95% non condensing0 ~ 3000 Meters

1 21 x 1 8 A h

1 2 /243x7Ah

1 2 /243x9Ah

483x12Ah

484x12Ah

48/964x18Ah

9616x7Ah

DP Electronics e.K(Deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

[Extended Version][Short backup]

Page 10: XL SERIES - Delta Technologies

I.T GRADE ONLINE DOUBLE CONVERSION UPS1KVA ~ 10KVA (1/1)

M i s s i o n C r i t i c a l &I . T G r a d e U P S

ELEKTRA SERIES

Page 11: XL SERIES - Delta Technologies

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

Elektra Series H.F range of On Line Double ConversionUPS’s uses microprocessor control technologyintended in particular for users of critical systems thatrequire reliability and high performance at the sametime (telecommunications equipment, criticalindustrial applications, etc.).

Elektra uses technology which delivers a perfectsinusoidal output current and provides effectiveprotection of critical devices.Elektra Series UPS’s provides an upgraded power factorreaching 0.9 for single phase systems, therefore offerhigher performance and improved efficiency for vitalapplications.

UPS status can be monitored at a glance on an intuitiveLCD screen. Elektra Series offer redundant and capacityparallel UPSs, the right solution for all applicationsrequiring a perfect and uninterrupted power supply.

This is a green product that comply with theproducts pollution control managementmeasures, the product under normal use, willnot harm the environment and personalsusing it.

Elektra Series (1/1, H.F) (1KVA~10KVA)

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 12: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

Safety : Comply with GB4943-2001, IEC62040-1and CE requirements.Industry Standard :Comply with EN62040,YD/T1095-2000 requirements.

FOR 1/2/3 KVA UPS products comply with:EN50081-1 / EN55022 Class B - EN50082-1 / IEC801-2 LEVEL 4IEC801-3 LEVEL 3 - IEC801-4 LEVEL 4 - IEC801-5 LEVEL 2(1) 1000VA, 2000VA, and 3000VA (220/230V-version) productscomply with: FCC Part 15 Class A - IEEE587 Class A(2) The products of 3000VA (220/230V-version) are ClassA digital devices.

Standards

Powerful Extensibility FeaturesSmart slot provides rich scalable features, USB can beselected, AS400 card, SNMP card, RS485 card andenvironmental monitoring card.

Radiated Emiss ion: EN50091-2: L imits for UPS whichhave a rated output current exceeding 25A (25~100A)EMSEN61000-4-2(ESD)…………………….. . . . . . . . .…. . . .Level 4EN61000-4-3(RS)………………………….. . . . . . . . . . . . . . . . . . . Level 3EN61000-4-4(EFT)………………..……….. . . . . . . . . . . . . . . . . . Level 4EN61000-4-5(L ightning Surge)………….. . . . . . . . . . . . . . Level 4EN61000-2-2 ( Immunity to low frequency s ignal )

FOR 6K/10K/15K UPS products comply with:EN62040-1-1 (Safety).Conducted Emission: EN50091-2: Limits for UPS which havea rated output current exceeding 25A (25~100A)

N+X is currently the most reliable power supply structure.N represents the minimum required UPS number that the totalload needs; X represents the redundant UPS number. The biggerthe X is, the higher reliability of the power system is. For occasionswhere reliability is highly required, N+X is the optimal mode upto 3 of them can be connected in parallel to support outputpower sharing and power redundancy.

Parallel Configuration

Power Factor 0.9Adapting the current most electrical devices type it enhancesthe ability for supporting load of the machine. 0.9 power factor.

Input voltage and frequency range is wide so can effectivelyworks on generator sets and thus provide pure, safe and stablepower.

Compatible With Generators

Active Input Power Factor Correction (Pfc)With digital control of active power factor correction technology,enables high input power factor 0.99 above as to avoidcontamination of electrical network environment, saving energyand reducing system costs.

Output Switchboard

Load Load Load Load Load

Parallel Connectivity

Zero SwitchingThe transfer time when UPS transferred to the battery or viceversa is zero, effectively guarantee the load operation securityand reliability.

DSP Digital Control TechnologyDSP advanced digital control technology UPS, increasesperformance, stability, quality and reliability.

Wide Input Voltage & Frequency RangeVery wide input voltage and frequency ranges, even in harshelectrical environments will work in stable mode,which reducesthe number of battery discharge resulting in extended batterylife.

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 13: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATION FOR SINGLE PHASE IN & SINGLE PHASE OUT

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

MODEL

RANGE

INPUT

OUTPUT

BATTERY

GENERAL

ES101 ES101S ES102 ES102S ES103 ES103S ES106 ES106S ES110 ES110S

1KVA/900W 2KVA/1800W 3KVA/2700W 6KVA/5400W 10KVA/9000W

Single Phase + Neutral + Ground200 / 208 / 220 / 230 / 240VAC

40~70Hz>0.99

175~290VAC ±15%

110VAC~300VAC 120VAC~276VAC

Single Phase & Earth ground

±1%

36VDC 72VDC 96VDC

Input systemRated VoltageVoltage RangeFrequencyPower FactorVoltage Range Bypass

Output systemRated VoltagePower FactorVoltage PrecisionFrequency Normal

Frequency Battery

Overload Capacity

Short CircuitOver HeatBattery LowAmbient Temp.HumidityAltitudeStroge Temp.Noice LevelCommunication InterfaceEPO (Optional)Audible & Visual Alaram

4 hours recover to 90% capacity192/216/240VDC

0°C~40°C20%~90% (No condensation)

Lower than 1000m: no detracting: Over 1000m 1% detracting for every 100m rise-15°C~45°C

<50dBARs232, USB, (SNMP, Parallel card, Relay card and RJ45 are optional)

Emergency Power OffLine Failure, Battery low, Over Load, System Fault

Single Phase + Nutral + Ground200 / 208 / 220 / 230 / 240VAC

0.9 / 1.0

VoltageTypical Recharge T imeCharging Amperes

1. The output frequency synchronizes with the input frequency when the inputfrequency is in the range of 47~53Hz or 57~63 Hz

50 / 60 ± 0.1%

1A /2A ~ 12A Auto Sensing

0ms (Normal mode<------->Battery mode), <4ms (Normal mode <------> Bypass mode)3:1

Transfer T imeCrest Factor

105%~110%:UPS transfer to bypass after 10 minutes when the utility is normal110%~130%:UPS transfer to bypass after 5 minutes when the utility is normal130%~150%:UPS transfer to bypass after 1 minutes when the utility is normal

>150%:UPS transfer to bypass immidiately when the utility is normal

System FreezesLine Mode: Switch to bypass. Backup Mode: Shut down UPS immediately

Alarm and switch off

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)DP Electronics (Deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.Note: For Rack Mount UPS only add “RTS“ in the standard model name, Eg. (ES101RT) for 1Kva RT UPS.

Page 14: XL SERIES - Delta Technologies

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

TECHNICAL SPECIFICATION FOR SINGLE PHASE IN & SINGLE PHASE OUT

MODEL

RANGEES101 ES101S ES102 ES102S ES103 ES103S ES106 ES106S ES110 ES110S

1KVA/900W 2KVA/1800W 3KVA/2700W 6KVA/5400W 10KVA/9000W

DP Electronics (Deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

DIMENSION TOWER TYPE

DIMENSION RACK TYPE

144x229x350 144x229x350 190x328x424 190x328x424 190x328x424 190x328x424 260x570x717 260x570x717 260x570x717 260x570x71711.5 6 24 12 28 12 90 35 93 38

12Kg 22Kg440x86.5x410

STANDRADSIEC/EN62040-1,IEC/EN60950-1

IEC/EN62040-2,IEC6100-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

Note: For Rack Mount UPS only add “RTS“ in the standard model name, Eg. (ES101RT) for 1Kva RT UPS.

Size WxHxDWeight

SizeWeight KgInput ConnectionOutput ConnectionExternal Battery Connection

SeaftyEMC

440x86.5x620

2Amp.6Pcs

ModelBattery TypeBatt. DC VoltageMax.QuantityMax.Charge CurrentBatt.Bank Size WxHxD (mm)Weight (kg)

BATTERY BANK

26.6Kg 23Kg 25Kg443x131x580

IEC320-C14-10A IEC320-C20-16A IEC320-C20-16AIEC320 C13-10A X 6 IEC CL3-10A X 8 IEC320 C13-10A X 8 & C19-16A X 1

Anderson like PowerPole Modular Connectors

HardwireHardwire & IEC320-c13-10A x 2

RT-BR06007 RT-BR12007 RT-BR12009 RT-BR20007 RT-BR200097Ah 7Ah 9Ah 7Ah 9Ah

36Vdc 72Vdc 72Vdc 192/216/240VDC12Pcs 12Pcs 16Pcs/18Pcs/20Pcs

440x86.5x410 440x86.Sx620 443x131(3U)x58016.2 29.4 33 58 67

Page 15: XL SERIES - Delta Technologies

Deutsc

he Pow

erI.T GRADE ONLINE DOUBLE CONVERSION UPS

10KVA ~ 20KVA (3/1)

M i s s i o n C r i t i c a l &I . T G r a d e U P S

ELEKTRA SERIES

Page 16: XL SERIES - Delta Technologies

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

Elektra Series H.F range of On Line Double Conversion UPS’suses microprocessor control technology intended inparticular for users of critical systems that require reliabilitya n d h i g h p e r f o r m a n c e a t t h e s a m e t i m e(telecommunications equipment, critical industrialapplications, etc.).

Elektra uses technology which delivers a perfectsinusoidal output current and provides effectiveprotection of critical devices.Elektra Series UPS’s provides an upgraded power factorreaching 0.9 for single phase systems, therefore offerhigher performance and improved efficiency for vitalapplications.

UPS status can be monitored at a glance on an intuitiveLCD screen. Elektra Series offer redundant and capacityparallel UPSs, the right solution for all applicationsrequiring a perfect and uninterrupted power supply.

This is a green product that comply with theproducts pollution control managementmeasures, the product under normal use,will not harm the environment andpersonals using it.

Elektra Series (10KVA~20KVA)

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 17: XL SERIES - Delta Technologies

Deutsc

he Pow

er

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

Elektra range provide a combination of outstandingprotection features and flexibility, making it the rightchoice for applications demanding optimum reliabilityand energy efficiency.It systems such as servers,networking devices, workstations, storage systems and along list of other IT equipment find the right protectionelement in Elektra, especially, when combined withElektra powerful Connectivity suite.

VolP equipment, railway control systems, medicallaboratory instrumentation, and many other industrialapplications may also benefit from the consistent andhigh quality power provided by the Elektra, thanks to therobustness, precision and high efficiency provided.

Application

Safety : Comply with GB4943-2001, IEC62040-1and CE requirements.Industry Standard :Comply with EN62040,YD/T1095-2000 requirements.

FOR 1/2/3 KVA UPS products comply with:EN50081-1 / EN55022 Class B - EN50082-1 / IEC801-2 LEVEL 4IEC801-3 LEVEL 3 - IEC801-4 LEVEL 4 - IEC801-5 LEVEL 2(1) 1000VA, 2000VA, and 3000VA (220/230V-version) productscomply with: FCC Part 15 Class A - IEEE587 Class A(2) The products of 3000VA (220/230V-version) are ClassA digital devices.

Standards

Powerful Extensibility FeaturesSmart slot provides rich scalable features, USB can beselected, AS400 card, SNMP card, RS485 card andenvironmental monitoring card.

Radiated Emiss ion: EN50091-2: L imits for UPS whichhave a rated output current exceeding 25A (25~100A)EMSEN61000-4-2(ESD)…………………….. . . . . . . . .…. . . .Level 4EN61000-4-3(RS)………………………….. . . . . . . . . . . . . . . . . . . Level 3EN61000-4-4(EFT)………………..……….. . . . . . . . . . . . . . . . . . Level 4EN61000-4-5(L ightning Surge)………….. . . . . . . . . . . . . . Level 4EN61000-2-2 ( Immunity to low frequency s ignal )

FOR 6K/10K/15K UPS products comply with:EN62040-1-1 (Safety).Conducted Emission: EN50091-2: Limits for UPS which havea rated output current exceeding 25A (25~100A)

N+X is currently the most reliable power supply structure.N represents the minimum required UPS number that the totalload needs; X represents the redundant UPS number. The biggerthe X is, the higher reliability of the power system is. For occasionswhere reliability is highly required, N+X is the optimal mode upto 3 of them can be connected in parallel to support outputpower sharing and power redundancy.

Parallel Configuration

Power Factor 0.9Adapting the current most electrical devices type it enhancesthe ability for supporting load of the machine. 0.9 power factor.

Input voltage and frequency range is wide so can effectivelyworks on generator sets and thus provide pure, safe and stablepower.

Compatible With Generators

Active Input Power Factor Correction (Pfc)With digital control of active power factor correction technology,enables high input power factor 0.99 above as to avoidcontamination of electrical network environment, saving energyand reducing system costs.

Output Switchboard

Load Load Load Load Load

Parallel Connectivity

Zero SwitchingThe transfer time when UPS transferred to the battery or viceversa is zero, effectively guarantee the load operation securityand reliability.

DSP Digital Control TechnologyDSP advanced digital control technology UPS, increasesperformance, stability, quality and reliability.

Wide Input Voltage & Frequency RangeVery wide input voltage and frequency ranges, even inharsh electrical environments will work in stablemode,which reduces the number of battery dischargeresulting in extended battery life.

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 18: XL SERIES - Delta Technologies

Deutsc

he Pow

erThree Phase + Neutral + Ground

3 X 400 VAC ( 3Ph + N )±20%

50/60Hz0.99

(120±5) VAC ~ (264±5) VAC

Single Phase & Earth ground208 / 220 / 230 / 240 VAC

0.9

1. The output frequency synchronizes with the input frequency when the inputfrequency is in the range of 46 Hz~54 Hz

2. The output frequency is 50 Hz when the input frequency is not in the range of 46 Hz~54 Hz105%±5%<Load <125%±5% 50s transfer to bypass125%±5%<Load <150%±5% 25s transfer to bypass

Load >150%±5% 300ms transfer to bypass0ms (Normal mode<------->Battery mode)<4ms (Normal mode <------> Bypass mode)

3:1

240VDC 20 Pcs 20 Pcs x 2 String

Sealed maintenance-free lead-acid (12Vx 9AH)7A

0°C~40°C20%~90% (No condensation)

Lower than 1000m: no detracting: Over 1000m 1% detracting for every 100m rise-15°C~45°C

592 X 250 X 576 815 X 250 X 826

TECHNICAL SPECIFICATION FOR THREE PHASE IN & SINGLE PHASE OUT

MODEL

RANGE

INPUT

OUTPUT

BATTERY

GENERAL

DIMENSION TOWER TYPE

VoltageQuantityTypeCharging Amperes

Ambient Temp.HumidityAltitudeStorage Temp.

Size (DxWxH)mmWeight Kg.

ES3110 ES3115 ES3120

10KVA/9000W 15KVA/13500W

±1%±2%

20KVA/18000W

83 / 28 164 / 40

DP Electronics e.K(Deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Input SystemRated VoltageVoltage RangeFrequencyPower factorVoltage range of bypass

Output SystemRated VoltagePower factorVoltage precisionFrequency Normal

Frequency BatteryOver-load Capacity

Transfer T ime

Crest Factor

Page 19: XL SERIES - Delta Technologies

I.T GRADE ONLINE DOUBLE CONVERSION UPS10KVA ~ 200KVA (3/3)

M i s s i o n C r i t i c a l &I . T G r a d e U P S

ELEKTRASMALL FOOT PRINT SERIES

Page 20: XL SERIES - Delta Technologies

Elektra Series I.T Grade On Line Double Conversion UPSrepresents the best solution that is both effective andenvironment friendly, it delivers and excellent integratedautonomy, reduced footprint and optimum input and outputperformances, guaranteeing reliable and flexible power.

Elektra Double conversion pure on-line three phase input andoutput UPS adopt double conversion technology, able toprovide solutions to conditions like voltage instantaneousdrop-off or damping concussion, high-voltage plus, voltagepulsation, surge voltage, harmonic distortion, and frequencyfluctuation, guarantees a safe and reliable power.

UPS status can be monitored at a glance on an intuitive LCDscreen.

Elektra Series offer redundant and capacity parallel Ups, theright solution for all applications requiring a perfect anduninterrupted power supply.

This is a green product that comply with theproducts pollution control managementmeasures, the product under normal use, willnot harm the environment and personalsusing it.

Elektra Series (3/3, H.F) (10KVA~200KVA)

I.T GRADE ONLINE DOUBLE CONVERSION UPS (SMALL FOOT PRINT)DP

Ele

ctro

nics

(De

utsc

he P

ower

Co.

, Lim

ited)

Page 21: XL SERIES - Delta Technologies

Standards

Powerful Extensibility FeaturesSmart slot provides rich scalable features, USB canbe selected, AS400 card, SNMP card, RS485 card andenvironmental monitoring card.

Safety:IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2,IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5,IEC61000-4-6, IEC61000-4-8

Noise SuppressionComplies with EN62040~2

The efficiency of the machine is as high as 94% andreaches over 98% in the ECO mode which can help toreduce the power loss of the UPS’s IGBT, FM, intelligentrectifier and inverter technology, input power factor 0.99,& input current harmonic wave (THDi) is as low as 3%.

High-efficient, Energy Saving,Green Environmental Protection

Power Factor 0.9The 0.9 Output Power Factor reaffirms your originalDeutsche Power RT Series purchase by fully leveragingyour existing UPS investment to accommodate today’sand tomorrow’s high power factor load requirements.

Input voltage and frequency range is wide so it caneffectively works on generator and thus provide pure,safe and stable power.

Compatible With Generators

Active Input Power Factor Correction (Pfc)With digital control of active power factor correctiontechnology, enables high input power factor 0.99 aboveas to avoid contamination of electrical networkenvironment, saving energy and reducing system costs.

Zero SwitchingTransfer time when UPS transferred to the battery or viceversa is zero, effectively guarantee the load operationsecurity and reliability.

Excellent Overload CapacityWhen higher protection required, the optional dust-proofaccessories can help to increase the protection level inharsh environment and safeguard the UPS’s security.Elektra series UPS provide a broader range of inputvoltage from 208VAC to 478VAC, which ensures to beapplicable in the unpleasant grid environment of differentp owe r s u p p l y e q u i p m e nt l i ke ge n e rato r, w i t h i t sextraordinary input frequency.

ApplicationRT Series range provide a combination of outstandingprotection features and flexibility, making it the right choicefor applications demanding optimum reliability and energyefficiency.Systems such as servers, networking devices, workstations,storage systems and various IT equipment find the rightprotection element in Elektra Series, especially, when combinedwith Elektra Powerful Connectivity suite.

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

Key FeaturesOnline-Double conversionOutput transfer time is OmsPFC technologyFull digital control (DSP)Output power factor: 0.9Input current harmonic: 3%ECO functionCharging/Rectifier/Inverter fully digital controltechnologyOptimization battery group, the quantity of battery:10- 30K (16/18/20 pes optional)40-80K (32/34/36/38/40 pes opt ional )W ide input voltage range: 208-478VacW ide input frequency range: 40-70HzDC startCommunication port: USB / RS232 / RS485 /Parallel port / Dry contactOptions: SNMP card/Relay cardLCD I LED double displayIntelligent charging managementEPO functionCommon battery groupThe output can meet 100% unbalanced load

VolP equipment, railway control systems, medical laboratoryinstrumentation, and many other industrial applications mayalso benefit from the consistent and high quality powerprovided by the Elektra, thanks to the robustness, precisionand high efficiency provided.

I.T GRADE ONLINE DOUBLE CONVERSION UPS (SMALL FOOT PRINT)

Page 22: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics (Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

MODEL

RANGE

INPUTNominal voltageOperating voltage rangeOperating frequency rangePower factor

Bypass voltage range

Bypass frequency rangeECO rangeHarmonic distortion (THDi)

Output voltagePower factorVoltage regulationFrequency: line mode

bat.modeCrest factorHarmonic distortion (THD)Efficiency

Battery Voltage

Charge Current(A)

Transfer timeOver LoadShort CircuitCommunication

Operating temperatureStorage temperatureHumidity rangeAltitudeNoise level

Dimension D x W x H (mm)Net Weight (kg)

SafteyEMC

ESHS1033 ESHS4033ESHS3033ESHS 2033ESHS1533

10KVA/9KW 40KVA//36KW30KVA/27KW20KVA/18KW15KVA/13.5KW

OUTPUT

BATTERY

SYSTEM FEATURES

115/57 170/63 171/64 223/71

380/400/415Vac, (3Ph+N+PE)208-478Vac

45-55Hz at 50Hz / 54- 66Hz at 60Hz (auto sensing)0.99

380Vac Max. voltage: +25%(optional +1 0%,+15%,+20%)400Vac Max. voltage: +20%(optional +1 0%,+15%)

415Vac Max.voltage: +15%(optional +10%)Min. voltage: -45% (optional -20%,-30%)

Frequency synchronize tracing range: ± 10%Same as bypass

<3% (100%non-linear load)

380/400/415Vac (3Ph+N+PE)0.9

±1%± 1%/ ± 2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency( optional)

50160( ± 0.1 )Hz3:1

2% with linear load 5% with non linear load94.5%

± 120Vdc (20pcs12V9AH); Long run

unit:± 96V/ ± 1 08V/

± 120Vdc (16/18 /20pcs optional)

Standard unit: ± 120Vdc(2x20pcs12V9AH);

Long run unit Optional Voltage:±96VI± 108VI± 120Vdc(16/18/20pcs optional)

± 120Vdc(3x20pcs12V9AH)

Long run unitOptional

Voltage:± 96V/ ±108V/± 120Vdc

(16/18/20pcsoptional)

Optional Voltage:± 192VI±204VI± 216VI±228VI

± 240Vdc(32/34/36/38/40pcsoptional)

(charge current can be set according to battery capacity installed)

Standard unit:1.35A

Long run unit:Max.current 1OA

Standard unit:2.7A

Long run unit:Max.current 1OA

Standard unit:4.05A

Long run unit:Max.current 15A

Max.current15A

Utility to Battery: Oms; Utility to bypass: OmsLoad:<; 110%: last 60min,:<; 125%: last 1Omin,:<; 150%: last 1min, >150% change to bypass.

Hold Whole SyetemUSB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card

(optional), Relay card (optionai).LBS port (only 60-80k)ENVIRONMENTAL

0-40"C-25- 55"C(No battery)

0-95% (Non condensing)< 1500m.When>1500m,lower the rated power for use

<55dB <58dB

828x250x868PHYSICAL

PHYSICALIEC/EN62040-1 ,IEC/EN60950-1

IEC/EN62040-2,1EC61 000-4-2,1EC61 000-4-3,1EC61 000-4-4,1EC61 000-4-5,1EC61 000-4-6,1EC61 000-4-8

I.T GRADE ONLINE DOUBLE CONVERSION UPS (SMALL FOOT PRINT)

Page 23: XL SERIES - Delta Technologies

ESHS8033ESHS6033

80KVA/72KW60KVA/54KW

ESHS10033

100KVA/90KW

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics (Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

MODEL

RANGE

INPUTNominal voltageOperating voltage rangeOperating frequency rangePower factor

Bypass voltage range

Generator inputHarmonic distortion (THDi)

Output voltagePower factorVoltage regulationFrequency: line mode

bat.modeCrest factorHarmonic distortion (THD)Efficiency

Battery Voltage

Charge Current(A)

Transfer timeOver Load

BackfeedAlarmProtectionRemote LCDCommunication

Operating temperatureStorage temperatureHumidity rangeAltitudeNoise level

Dimension D x W x H (mm)Net Weight (kg)

SafteyEMC

OUTPUT

BATTERY

SYSTEM FEATURES

380/400/415Vac, (3Ph+N+PE)138~485Vac for 40%load; 305~485Vac for full-load

40~70Hz0.99

220Vac Max.voltage: +25%(optional +10%,+15%,+20% )230Vac Max.voltage: +20%(optional +10%,+15% )

240Vac Max.voltage: +15%(optional +10% )Min. voltage: -45% (optional -20%,-30%)

Frequency synchronize tracing range: ±10%Support

<3% (100% linear load )

380/400/415Vac (3Ph+N+PE)0.9

±1%Synchronize with input; when input frequency >±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz.

(50/60±0.1)Hz3:1

2% with linear load, 5% with non linear load95.60%

Utility to Battery : 0ms; Utility to bypass: 0ms110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 min

135% overload for long time; >1000% overload for 100 msSupport

Overload, utility abnormal, UPS fault, battery low, etc.Short circuit, overload, over temperature, battery low, fan fault alarm.

SupportUSB, RS485, Parallel port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional)

ENVIRONMENTAL<55dB <58dB

828x250x868

PHYSICAL

I.T GRADE ONLINE DOUBLE CONVERSION UPS (SMALL FOOT PRINT)

ESHS16033ESHS12033

160KVA/14472KW120KVA/108KW

ESHS20033

200KVA/90KW

Optional Voltage:±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50

pcs optional); 360Vdc~480Vdc (30~50 pcs, 32 pcs define, 32 and 50 pcs no power derating;Max.current 40A Max.current 60AMax.current 20A

0 C ~ 40 C25 C~55 C (no battery)

0~95% (noncondensing)< 1500m.When>1500m,lower the rated power for use

<60dB <63dB <65dB

850x442x1100 828x250x120068 72 115 120

IEC/EN62040-1 ,IEC/EN60950-1IEC/EN62040-2,1EC61 000-4-2,1EC61 000-4-3,1EC61 000-4-4,1EC61 000-4-5,1EC61 000-4-6,1EC61 000-4-8

INV. Mode

Bypass Mode

ENVIRONMENTAL

Page 24: XL SERIES - Delta Technologies

I.T GRADE ONLINE DOUBLE CONVERSION UPS10KVA ~ 500KVA (3/3)

M i s s i o n C r i t i c a l &I . T G r a d e U P S

ELEKTRA SERIES

Page 25: XL SERIES - Delta Technologies

Elektra Series I.T Grade On Line Double Conversion UPSrepresents the best solution that is both effective andenvironment friendly, it delivers and excellent integratedautonomy, reduced footprint and optimum input and outputperformances, guaranteeing reliable and flexible power.

Elektra Double conversion pure on-line three phase input andoutput UPS adopt double conversion technology, able toprovide solutions to conditions like voltage instantaneousdrop-off or damping concussion, high-voltage plus, voltagepulsation, surge voltage, harmonic distortion, and frequencyfluctuation, guarantees a safe and reliable power.

UPS status can be monitored at a glance on an intuitive LCDscreen.

Elektra Series offer redundant and capacity parallel Ups, theright solution for all applications requiring a perfect anduninterrupted power supply.

This is a green product that comply with theproducts pollution control managementmeasures, the product under normal use, willnot harm the environment and personalsusing it.

Elektra Series (3/3, H.F) (10KVA~500KVA)

I.T GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)DP

Ele

ctro

nics

(De

utsc

he P

ower

Co.

, Lim

ited)

Page 26: XL SERIES - Delta Technologies

Systems such as servers, networking devices, workstations,storage systems and various IT equipment find the rightprotection element in Elektra Series, especially, whencombined with Elektra Powerful Connectivity suite.

VolP equipment, railway control systems, medical laboratoryinstrumentation, and many other industrial applications mayalso benefit from the consistent and high quality powerprovided by the Elektra, thanks to the robustness, precisionand high efficiency provided.

Standards

Powerful Extensibility FeaturesSmart slot provides rich scalable features, USB canbe selected, AS400 card, SNMP card, RS485 card andenvironmental monitoring card.

Safety:IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2,IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5,IEC61000-4-6, IEC61000-4-8

Noise SuppressionComplies with EN62040~2

The efficiency of the machine is as high as 94% andreaches over 98% in the ECO mode which can help toreduce the power loss of the UPS’s IGBT, FM, intelligentrectifier and inverter technology, input power factor 0.99,& input current harmonic wave (THDi) is as low as 3%.

High-efficient, Energy Saving,Green Environmental Protection

Power Factor 0.9 ~ 1The 0.9 & 1 Output Power Factor reaffirms your originalDeutsche Power Elektra Series purchase by fullyleveraging your existing UPS investment to accommodatetoday’s and tomorrow’s high power factor loadrequirements.

Input voltage and frequency range is wide so it caneffectively works on generator and thus provide pure,safe and stable power.

Compatible With Generators

Active Input Power Factor Correction (Pfc)With digital control of active power factor correctiontechnology, enables high input power factor 0.99 aboveas to avoid contamination of electrical networkenvironment, saving energy and reducing system costs.

Zero SwitchingTransfer time when UPS transferred to the battery or viceversa is zero, effectively guarantee the load operationsecurity and reliability.

Excellent Overload CapacityWhen higher protection required, the optional dust-proofaccessories can help to increase the protection level inharsh environment and safeguard the UPS’s security.Elektra series UPS provide a broader range of inputvoltage from 210VAC to 475VAC, which ensures to beapplicable in the unpleasant grid environment of differentp owe r s u p p l y e q u i p m e nt l i ke ge n e rato r, w i t h i t sextraordinary input frequency.

I.T GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

ApplicationElektra range provide a combination of outstandingprotection features and flexibility, making it the right choicefor applications demanding optimum reliability and energyefficiency.

Key FeaturesAdvance IGBT Rectifier technology, input powerfactor: 0/99

Input THDi <3%

The efficiency of the machines is as high as 94%.

Connect parallel for maximum flexiblity andcompatible to battery share in the parallel mode,which helps the customers to extend the systemcapacity with low cost.

Intelligent management of battery charging anddischarging.

Lightning and surge protection, short circuit andoverload protection.

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

Page 27: XL SERIES - Delta Technologies

I.T GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

MODEL

RANGE

INPUTPrincipal of workingPhaseVoltagePower FactorFrequencyHarmonic Distortion (THDi)

Bypass Voltage

Voltage / RegulationPower FactorFrequency

Crest FactorHarmonic Distortion (THDi)

Efficiency

VoltageCharge Current (A)(It can be set according tobattery capacity installed)Battery

Transfer timeOverload: Line Mode

Bat. ModeLCD DisplayCommunication Interface

Oprating TemperatureStroage TemperatureHumidity RangeAltitudeNoice Level

Dimension D x W x H (mm)Net Weight (kg)

Safety

Noise Suppression

ESH1033 ESH8033ESH6033ESH4033ESH3033ESH 2033ESH1533

10KVA/9KW 80KVA/72KW60KVA/54KW40KVA//36KW30KVA/27KW20KVA/18KW15KVA/13.5KW

True On-line, Double Conversion, Static Bypass SwitchThree phase + N + PE

208~478V

40/70Hz2% (100% non-linear load)

Max.Volt.: 220V+25%(optional + 10%,+15%,+20%) 230V 20% (optional +10%, +15%) 240V 15% (optional +10%)Minimum volt.: -45% (optional -20%, _30%)

Frequency Protection Range: ± 10%

380/400/415V (Adjustable), Three Phase + N + PE , ±2%0.9

1.Line Mode: ±1% / ±2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (optional)2.Battery Mode: (50/60±0.2%)Hz

3:1<2% with linear load

<5% with non linear load

Standrad unit: ± 216Vdc; Long run unit Optional: ± 192V\ ± 240V\ ± 216V\± 228V\ ± 240V

Advance Battery Management

Utility to battery: 0ms; Utility to bypass:0ms

>0.99

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics e.K(Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

94.5%

5.7A (Max ./standard un i t )6 .0A (Max ./Long run un i t )

12A (Max.) 18A (Max.)

Load<110%:last 60min, <125%: Last 10min, < 150%: Last 5min,>150% shutdown UPS ImmediatelyLoad<110%:last 10min, <125%: Last 1min, < 150%: Last 5S,>150% shutdown UPS Immediately

Input Voltage & Frequency, Output Voltage & Frequency Load Percentage, Battery Voltage & inner Temp.RS232, RS485,Parallel,Intelligent slot,Relay Card (Optional, SNMP) Card (optional)

0 ~ 40C-25~55C

0~95% (non condensing)<1500m<55db

780 x 600 x 1200

Safety: IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2, IEC61000-4-2, IEC61000-4-3,IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

Complies with EN62040~2

OUTPUT

BATTERY

SYSTEM FEATURES

ENVOIRMENTAL

PHYSICAL

STANDRADS

S:591H;123

S:594H;126

S:595H;127

S:595H;127 158 158 195

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

Page 28: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

MODEL

RANGE

INPUTPrincipal of workingPhaseVoltagePower FactorFrequencyHarmonic Distortion (THDi)

Bypass Voltage

Voltage / RegulationPower FactorFrequency

Crest FactorHarmonic Distortion (THDi)

Efficiency

VoltageCharge Current (A)(It can be set according tobattery capacity installed)Battery

Transfer timeOverload: Line Mode

Bat. ModeLCD DisplayCommunication Interface

Oprating TemperatureStroage TemperatureHumidity RangeAltitudeNoice Level

Dimension D x W x H (mm)Net Weight (kg)

Safety

Noise Suppression

ESH10033 ESH30033ESH16033ESH12033

90KW/100KW

True On-line, Double Conversion, Static Bypass SwitchThree phase + N + PE

208~478V

40/70Hz2% (100% non-linear load)

Max.Voltage: 220V+25%(optional + 10%,+15%,+20%) 230V 20% (optional +10%, +15%) 240V 15%(optional +10%) Minimum voltage: -45% (optional -20%, _30%)

Frequency Protection Range: ± 10%

380/400/415V (Adjustable), Three Phase + N + PE , ±1%

1.Line Mode: ±1% / ±2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (optional)2.Battery Mode: (50/60±0.2%)Hz

3:1<2% with linear load

<5% with non linear load

Standrad unit: ± 216Vdc; Long run unit Optional: ± 192V\ ± 240V\ ± 216V\± 228V\ ± 240V

Advance Battery Management

Utility to battery: 0ms; Utility to bypass:0ms

>0.99~1

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics e.K(Deutsche Power Co. L imited) has a pol icy of cont inuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

94.5% / 96% Customized

24A(Max.)

Load<110%:last 60min, <125%: Last 10min, < 150%: Last 5min,>150% shutdown UPS ImmediatelyLoad<110%:last 10min, <125%: Last 1min, < 150%: Last 5S,>150% shutdown UPS Immediately

Input Voltage & Frequency, Output Voltage & Frequency Load Percentage, Battery Voltage & inner Temp.RS232, RS485,Parallel,Intelligent slot,Relay Card (Optional, SNMP) Card (optional)

0 ~ 40C-25~55C

0~95% (non condensing)<1500m

Safety: IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

Complies with EN62040~2

OUTPUT

BATTERY

SYSTEM FEATURES

ENVOIRMENTAL

PHYSICAL

STANDRADS286 288 348 380 600 815 860

ESH20033 ESH40033 ESH50033

108KW/120KW 144KW/160KW 180KW/200KW 270KW/300KW 360KW/400KW 450KW/500KW

24A(Max.)

36A(Max.)

50A(Max.)

80A(Max.)

100A(Max.)

130A(Max.)

70db 73db

780 x 600 x 1200 800x600x1600 850x600x1600 850 x 1200 x 2000

I.T GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

0.9/1(Customized)

100KVA 300KVA160KVA120KVA 200KVA 400KVA 500KVA

Page 29: XL SERIES - Delta Technologies
Page 30: XL SERIES - Delta Technologies
Page 31: XL SERIES - Delta Technologies
Page 32: XL SERIES - Delta Technologies
Page 33: XL SERIES - Delta Technologies

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS10KVA ~ 40KVA (3/1)

M i s s i o n C r i t i c a l &I n d u s t r i a l G r a d e U P S

ELEKTRA SERIES

Page 34: XL SERIES - Delta Technologies

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

Elektra Series On-Line Double Conversion Industrail GradeUPS. It is a collection of digital, informational & network usesone of high intelligent microprocessor control technologyintended in particular for users of critical systems that requirereliability and high performance at the same time(telecommunications equipment, critical industrial applications,etc.). Visual display and state monitroing interface, make eachuser operate simplu and conveniently.

Elektra uses technology which delivers a perfect sinusoidaloutput current and provides effective protection of criticaldevices. Elektra Series UPS’s provides an upgraded powerfactor reaching 0.9 for single phase systems, therefore offerhigher performance and improved efficiency for vitalapplications.

UPS status can be monitored at a glance on an intuitive LCDscreen. Elektra Series offer redundant and capacity parallelUPSs, the right solution for all applications requiring a perfectand uninterrupted power supply.

This is a green product that comply with theproducts pollution control managementmeasures, the product under normal use,will not harm the environment andpersonals using it.

Elektra Series (3/1, L.F) (10KVA~40KVA)

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 35: XL SERIES - Delta Technologies

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

Elektra range provide a combination of outstanding protectionfeatures and flexibility, making it the right choice forapplications demanding optimum reliability and energyefficiency. It systems such as servers, networking devices,workstations, storage systems and a long list of other ITequipment find the right protection element in Elektra,especially, when combined with Elektra powerful Connectivitysuite.

VolP equipment, railway control systems, medical laboratoryinstrumentation, and many other industrial applications mayalso benefit from the consistent and high quality powerprovided by the Elektra, thanks to the robustness, precisionand high efficiency provided.

ApplicationInput voltage and frequency range is wide so can effectivelyworks on generator sets and thus provide pure, safe andstable power.

Compatible With Generators

Parallel ConfigurationN+X is currently the most reliable power supply structure. Nrepresents the minimum required UPS number that the totalload needs; X represents the redundant UPS number. Thebigger the X is, the higher reliability of the power system is.For occasions where reliability is highly required, N+X is theoptimal mode up to 3 of them can be connected in parallelto support output power sharing and power redundancy.

DSP Digital Control TechnologyDSP advanced digital control technology UPS, increasesperformance, stability, quality and reliability

Strong Protection for loadBuilt-in isolation transformer, strong anti-interference ability,provide more comprehensive protection.

Wide Input Voltage & Frequency RangeWide input voltage range upto : 304~456Vac, avoid frequentlyswitching to battery mode, which adapt to the areas withharsh environment.Wide input frequency range, ensure all types of fuel generatorsconnected work stable.

Smart slot provides rich scalable features, USB can be selected,AS400 card, SNMP card, RS485 card and environmentalmonitoring card.

Powerful Extensibility Features

Active Input Power Factor Correction (Pfc)With digital control of active power factor correctiontechnology, enables high input power factor 0.99 above as toavoid contamination of electrical network environment, savingenergy and reducing system costs.

StandardsSafety:IEC/EN62040-1; IEC/EN60950-1; IEC/EN62040-2:IEC61000-4-2; EC61000-4-3; IEC61000-4-4;IEC61000-4-5; IEC61000-4-6; IEC61000-4-8;

Network Management DesignThrough RS232 interface and intelligent monitor software tocommunicate with the computer, and the various permeatesof UPS clear display on the communication interface.

External SNMP adapter, UPS with remote networkmanagement capabilities, providing real time UPS date andpower information through a variety of network operatingsystem for communicat ion and management .

Key FeaturesPure online double conversion technology, to provide thebest quality of power supply.Suitable for all kinds of loads, and high overload capacity.Super wide range of output voltage anti-interference,adapt to harsh environment in power network.Intelligent battery management, extending the battery life.Large LCD display English and many other languages, andFriendly human-machine interface.

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 36: XL SERIES - Delta Technologies

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

MODEL

RANGEINPUT

Principal of workingPhaseVoltagePower FactorFrequencySoft Start

PhaseVoltageFrequencyCrest FactorEfficiencyHarmonic Distortion (THD)

Battery Voltage

Transfer TimeOverloadCommunication interface

Opration TemperatureStroage TemperatureHumidity RangeAltitudeNoise Level

Dimention D x W x H (mm)Net Weight (Kg)

SafetyEMC

ES 1031 ES 4031ES 3031ES 2531ES 2031ES 1531

10KV/9KW 40KV/36KW30KV/27KW25KV/22.5KW20KV/18KW15KV/13.5KW

>0.97 (with f i l ter)

TECHNICAL SPECIFICATION FOR THREE PHASE IN & SINGLE PHASE OUT

DP Electronics e.K(Deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

True On-line, Double Conversion, Static Bypass Switch, Output with transformerThree Phase + N + PE

380Vac(±20%)

50/60Hz±5%0-100% 5 Secs

Single Phase + N + G220Vac(±0.5%) / 230Vac(±0.5%)

50/60Hz(±5%)3:1 (max)

>90%<1.5%(linear load)

0ms (Line mode - Battery mode)>125% : 1min, >150%:200ms

RS232, SNMP (optional), Dry Contact (optional)

0~40C-25C~55C

0~95%(non-condensing)<1500m<55db

IEC/EN62040-1;IEC/EN60950-1IEC/EN62040-2:IEC61000-4-2;IEC61000-4-3;IEC61000-4-4;

IEC61000-4-5;IEC61000-4-6;IEC61000-4-8

OUTPUT

BATTERY192 VDC

SYSTEM FEATURES

ENVIROMENTAL

Dimention / Weight

STANDRADS 132

741 x 555 x 1200 800 x 600 x 1200

200 236 311 323 380

585 X 305 X 864 798X 2409X 71044

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

240 VDC

Page 37: XL SERIES - Delta Technologies

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS10KVA ~ 3.2MVA (3/3)

Ultimate PowerProtection for MissionCrit ical & I.T Grade UPS

ELEKTRA SERIES

Page 38: XL SERIES - Delta Technologies

Deutsche Power Elektra LF Series UPS is the world’s mostadvance true On-Line Uninterruptable Power System. ElektraLF series adopts Digital Signal Processor (DSP) technology,comprises of high current & high voltage Intelligent PowerModule, High Speed IGBT drive IC and professional drivecircuit, so it provides 100% Pure Sine Wave output, and itguarantees full safety of your highly sophisticated equipments.This series totally isolates its connected load from everypower problem that arises from the mains supply. It ensures100% protection to the load from the full range of powerdisturbances including harmonics, common-mode noise andfault conditions on the input bus and vice versa.

E l e k t ra I n d u st r i a l D es i g n S e r i esComprises of output power factor 0.9

Elektra LF Series (3/3) 10KVA~3.2MVA

T h r e e P h a s e I n & T h r e e P h a s e O u t( 1 0 K V A ~ 9 0 0 K V A )

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 39: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

1 + 1 / N + X

INPUT

FILTER RECTIFIER INVERTERTRANSFORMER

STATICSWITCH

FILTER

OUTPUT

BATTERY

The range of capacity for 3/3 is from 10KVA to 800KVA (StandAlone). It supports redundant parallel connected up to 8 sets.Each set of UPS wi l l share load automatically.Elektra series delivers an excellent integrated autonomy,reduced footprint, optimum input, output performances andguarantees reliable power by adapting its performances tomeet individual load requirements.

This UPS ensures full load protection by combining softwaresolutions, parallel redundancy, safety and disconnectingdevices, system bypass switches, and communicationsolutions, to deliver reliable high-quality AC power.Elektra Series due to its industrial grade nature is flexibleenough to meet any power, redundancy, harmonic controland battery backup time requirements and is fully compatiblewith real-time remote monitoring and diagnostic tools.

Controlled circuit of auxiliary power for each provide reliable,stable power protection so that ensure all the control circuit towork properly. To ensure the normal operation of UPS systemsplay a key role. Elektra Series UPS's auxiliary power adopt 1+1redundancy design, when one of the auxiliary power failure, canbe continued by another auxiliary power supply. UPS continueto operate normally, while the LCD screen displays this warningmessage. When N + X sets of UPS (up to 8 sets) are working inredundant parallel or capacity-expanded parallel working modes,each set of UPS will automatically share the load. If one set ofUPS does not work due to malfunction, the UPS will automaticallyexit from operation, and the other sets of UPS will share the load.If the system is overloaded, all the UPS system will turn to bypassoperation. Parallel working can be classified into many workingmodes such as normal working mode, battery working mode,bypass power supply mode, maintenance working mode,combined power supply mode, and so on.

N+X Redundant Design

Parallel ConnectivityParallel Connectivity is available up to 8 Units, which further improvethe reliability and compatibility of the UPS. This system ensuresmore sensitive and reliable operations of the UPS to continuefeeding the load through parallel connectivity even if one unit isout of order the other unit still operate and ensures a continoussupply with out any interruption.

Elektra series UPS replaces traditionally insert electric circuitprocessing with high precession SMD technology. Thisinnovation not only save the space but also drasticallyeliminate the distortion of insert components in traditionalUPS circuit. What’s more, it ensures the integrate circuit asafe operation and enhances its reliability & operationprecision.Elektra series UPS, widely using SMD technology, is heat-resistant, highly accurate and also has an excellent filter,which greatly improves the whole performance of the UPS.It is more durable and its lifetime is prolonged by 80%.

High Precision SMD Technology

An important consideration has been given to allow generousaccess to the units electronic cards and power components.All the boards are accessible by the front panel for easilymaintenance and replacement.

Front access Maintenance

Elektra Series is equipped with Class-C lightning-proof systemserves as a protection measurement for the alternative powerinput into the computer room to prevent external lightningstrike or electrical surge voltage from entering the computerroom and from any damage to the equipment installed therein.This accessory system should be selected if no Class-C or belowlightning proof system is set up in the low voltage powerdistribution system output terminals, the computer room isfar from low voltage power distribution output or it is thespecial area liable to lightning strikes. Class-C lightning-proofsystem is designed for a max 20 KA for current flow and 8/20µsfor impulse current wave form.

Class-C Lightning-Proof System

Elektra Series adopts DSP, MCU and DDC real time processingall digital vector Control technology which increases powercomponent performance and enable active conditioning ofthe load. Due to this technology UPS can bear unbalanceload and can distribute perfectly in parallel mode

Leading Technology

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 40: XL SERIES - Delta Technologies

Batteries are connected with UPS by an external battery switch,the battery switch is a ''three-stage'' DC switch that can bemanually closed, and has a control circuit controlled by the UPSelectronic tripping device. Effectively reducing the past due tobattery leakage or short circuit caused the fire risk for the safeoperation of the UPS has provided a guarantee.

UPS is equipped with a emergency stop button, this emergencystop button can be used remotely to shutdown the UPS.

Unique Battery Protection Function & Management

Elektra series is equipped with Touch Screen LCD allowingenhanced features to be store and display with easy to view,the details of viewing features on the LCD are as follows:-

UPS Information-Rectifier Information-Inverter Information-Battery Information-Logging History-Alarms Information-Load Information

Touch Screen LCD Display

Industrial Machines, Large mainframe oriented data centers,Computer rooms; Small mainframe Mini computers, Centralizedor clustered servers, Tele communications applications, Medicalanalysis equipment such as MRI and CAT scanners, Laboratoryinstrumentation, Mission critical customized applications

Applications

For many years we have measured IT equipment loads withpower factors in the range 0.6 to 0.9 lagging. As a consequencewe have designed products with practical ratings in mind andwe have standardized on 0.9 power factor (pf) lag as a meansof determining nominal KVA/KW ratings. This rating conventionhas been adopted almost universally across the industry and so,for example, we have 90 KVA/80 KW as a standard frame rating.

Power Factor 0.9

The Elektra Series has an advance Battery managment functionincluding Battery malfunction test, prediction of backup timeafter battery discherge, Battery self test etc.

Elektra uses intelligent double conversion technology. Thisarchitecture combines the secure power provided bytraditional double conversion with the efficiency provided bydigital interactive technology. Up to eight Elektra units maybe connected in parallel, allowing you to customize and adaptour solution to yours changing load requirements.Elektra is available in the following configurations:Distributed Parallel; increasing power of the supply systemwhilst controlling costs, Centralized Parallel; using an additionalcommon output cubicle and providing a standby reserve linefor the whole system HFC (High Fault Clearance) Parallel;enabling simultaneous switching on of all available standbyreserve lines, with a downstream fault clearing capacity thatis four times higher.

Reliability

Safety: EN62040-1-1Conducted Emission: EN50091-2Radiated Emission: EN50091-2 - EMSEN61000-4-2(ESD)..... Level4EN61000-4-3 (RS)……………....................................................Level4EN61000-4-(EFT)…...............................................................Level4EN61000-4-5(Lightning surge)..............................................Level4EN61000-2-2 (Immunity to low Frequency signal)

Standard

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

Set the maximum output power of the generator when asmaller one than needed is employed to extend the batteryduration time. in this case, the load is supplied by both thegenerator battery.

Generator Mode

LBS synchronizationSynchronize the output of the two independent UPS system(singal unit or parallel) even when the two systems areoperating on different modes (bypass / inverter) or on battery.

Multi-protectionSelf-diagnosis function will take placce before start-up forsafty.

Multi-protection: AC input under/over voltage, overload,short-circuit, over-current, over bus voltage, over temprature,fan failure, auxliary power failure, battery under voltage,battery over-charge and so on.

Optional FeaturesSpecial fetures available on demand. Harmonic filter, SNMPadopter, LBS cables, Battery temperature sensor, Bypasscurrent-sharing inductor.

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 41: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

SNMP Card | Parallel Card | Dry Contact Card | C-Class LightingProtection | Battery Temperature Transmitter | JBUS /MODBUS Interface Cards | Telecommunication Port | RS232/ RS485 Environmental Card | GPRS Card | Standard ShutdownSoftware

Using user-friendly control panel modular in-line graphicdesign, to ensure reliable connection between the plug plates,the connection is configured with a connector lockingmechanical "locking" device. Users simply open the cabinetdoor that can be observed a glance at the control panel ofthe UPS "self-diagnosis".

Easy Maintenance of Structure Design

Front wiring terminationfor easy access

Front termination ofbreakersfor easy access

Communication

SNMP

SNMPTRAP

EntornatNetwork

WEBPAGE

SHUTDOWN

Server 2

Server 1

WindowsWorkstation

AdministratingWorkstation

RS232Terminal

RS232Link

AS400

MODBUS

EnvironmentalSensor

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 42: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

MODEL

RANGE

INPUT

BYPASS OUTPUT

AC OUTPUT

Principal of workingPhaseVoltagePower FactorFrequencySoft Start

PhaseVoltageFrequencyTransfer Time

DC VoltageFloat Chg. Voltage.Battery CabinetMax. Dischg. CurrentChg. Current

PhaseVoltageFrequencyPower FactorWave FormTHDDynamic Respond rangeDynamic Respond timeVoltage. UndulationOver LoadWorking efficiencyCommunicationTemperatureHumidityNoiseDimension (L x W x H)Weight (Kg)

ES1033 E S 8 0 3 3E S 6 0 3 3E S 4 0 3 3E S 3 0 3 3E S 2 0 3 3E S 1 5 3 3

1 0 K VA /9 K W 8 0 K V A /7 2 K W6 0 K V A / 5 4 K W4 0 K VA / /3 6 K W3 0 K VA /2 7 K W2 0 K V A / 1 8 K W15KVA/13.5KW

True On-l ine, Double Conversion, Static Bypass Switch, Output with transformerThree phase + N + G380/400/415V±20%

45~65Hz0-100% 5 Secs

Three Phase + N + G380/400/415V+20-40% (Adjustable)

±10% (Adjustable)0ms (When Overload)

To be External ly Connected

10-25A (Adjustable)

Three Phase + N + G380/400/415V±1% (Balance load)

50/60Hz±0.05% (Battery)0.9 LaggingSine wave

Linear load<3%, Non-l inear load<5%±5% (From 0 to 100%)

<10ms (±5%)<±3% (Unbalance Load) <±1% (Balance Load)

105%=load<125%,10min - 125%=load<150%,1min>91%, 95%, ECO

RS232/RS485, SNMP (Optional) Dry Contact0-50°C

<95% when 20°C50dB 60dB 63dB 65dB 68dB

DC SYSTEM

>0.98 (with f i l ter)

432 V 446V

25 13310271554033

8 3 2 x 4 3 0 x 1 1 0 5 m m 7 1 5 x 6 7 5 x 1 4 0 5217 525483330316273273

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics (Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

384V

Page 43: XL SERIES - Delta Technologies

DP E

lect

roni

cs (

Deut

sche

Pow

er C

o., L

imite

d)

MODEL

RANGE

INPUT

BYPASS OUTPUT

AC OUTPUT

Principal of workingPhaseVoltagePower FactorFrequencySoft Start

PhaseVoltageFrequencyTransfer Time

DC VoltageFloat Chg. Voltage.Battery CabinetBattery TypeChg. Current

PhaseVoltageMax. Output currentFrequencyPower FactorWave FormTHDDynamic Respond rangeDynamic Respond timeVoltage. UndulationOver LoadWorking efficiencyCommunicationTemperatureHumidityNoiseDimension (L x W x H)Weight (Kg)

ES10033 ES50033ES40033ES30033ES20033ES16033ES12033

100KV/90KW 500KV/450KW400KV/360KW300KV//270KW200KV/180KW160KV/144KW120KV/108KW

True On- l ine , Double Convers ion, S tat ic Bypass Switch , Output wi th t ransformerThree phase + N + G380/400/415V±20%

50/60Hz±10%0-100% 5 Secs

Three Phase + N + G380/400/415V+20-40% (Adjustab le)

±10% (Adjustab le)0ms (When Over load)

10-25A (Adjustab le)

Three Phase + N + G380/400/415V±1% (Ba lance load)

50/60Hz±0.05% (Battery)0 .9 Lag g ingS ine wave

L inear load<2%, Non- l inear load<5%±5% (From 0 to 100%)

<10ms (±5%)<±3% (Unbalance Load) <±1% (Ba lance Load)110% /60mins ; 125% /10mins ; >150% /1mins

>91%, 96%, ECORS232/RS485, SNMP (Opt iona l ) Dry Contact

0-50°C0-95%

65db

DC SYSTEM

>0.98 (with f i l ter)

4 3 2 V 5 6 4 V

Seald Led Acid Mentenance Free/ Gel Type

8 0 5 x 1 1 6 0 x 1 6 0 0 m m 1040x2800x1900800 45002050180014251219903

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics (Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

ES60033 ES80033

>0.85 (with f i l ter)

600KV/540KW 800KV/720KW

945x1400x1900mm 1040x1640x1900 1100x3900x19503700 6400

70dB

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

3 8 4 V

To b e E x t e r n a l l y C o n n e c t e d

Page 44: XL SERIES - Delta Technologies

Deutsc

he Pow

erONLINE DOUBLE CONVERSION UPS

10KVA ~ 520KVA (3/3)Modular Redundant Design

U l t i m a t e P r o t e c t i o nM i s s i o n C r i t i c a l &I . T G r a d e U P S

FUHRER SERIES

Page 45: XL SERIES - Delta Technologies

Deutsc

he Pow

erUPS For Mission Critical & IT, Industrial Equipments

Fuhrer Series ( 3/3) 10KVA ~ 520KVA

Fuhrer Series is a Multi-Standard Modular High frequencytechnology Parallel redundant UPS system. Fuhrer UPSset of today's most advanced technology applicationachievement, has the most advanced and sophisticatedtechnology, with innovative excellence concept focusingon the development of the global power, in order to pushUPS power fields of technological progress and the birthof high-end products.

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)MODULAR ON-LINE DOUBLE CONVERSION UPS (Fuhrer

Series)

This innovative state of the art scalable, redundant UPSsystem focuses on elevating the users’ experience tonew heights. With the highest efficiency rate of 96% anda significantly smaller footprint, the product offers aleading solution in the range of up to 500 kW/kVA.

Page 46: XL SERIES - Delta Technologies

Deutsc

he Pow

er

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

Multi-settingAccording to input power condition, user can set up the UPS configurationwith 4 kinds of working model (3 phase in & 3phase out, 3 phase in& 1 phase out, single phase in & out, single phase in & 3 phase out )

Intelligent recharging systemFuhrer UPS system applies a two step intelligent charging system. Thefirst stage is a constant charging current that can recharge the batterycapacity to 90% very quickly. The system then transfers to a constantvoltage mode to guarantee the battery can stay fully charged all the time.This intelligent charging system not only reduces the battery rechargingtime but also extends battery life, saving on battery replacement costs.

High capacity MTBFSystem MTBF for two modules in parallel is more than 1,000,000 hoursand power availability is above 99.999%. Each redundant configurationguarantees correct operation even in the event of the failure of one of theUPS modules. The module replacement procedure only takes 5 minutesfor full system recovery.This solution allows you to: • Minimize downtime; • Reduce the numberof stored spare parts; • Avoid the need for specialized technicians

Bypass moduleHigh reliability, overload capacity: 100% for one minute The switchingtime of less than 0ms Possess very strong post, interlock, protection,and other functions Equipped with USB, RS232, RS458, communicationfunction Replacement does not affect the power supply to the load

StandardSafety: IEC / EN62040-1,

IEC / EN60950-1EMC: IEC / EN62040-2,

IEC61000-4-2, IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6, IEC61000-4-8

Noise: EN62040-2

Comparison of Modular UPS with Traditional UPS.

Hot-SwappableInput PF

Input THDModularityReliablity

MTTRExpansion

Redundancy

Features Single UnitNo

0.7-112.33%

NoLow

>1 hourN/AN/A

1+1 Parallel UPS FuhrerNo

0.7-112.33%

NoHigh

>2 hourN/A

50% (fixed)

Yes0.995%YesHigh

10 minsHigh

0-90% (optional)

ApplicationLarge mainframe oriented data centers Computer rooms Small mainframeMini computers Centralized or clustered servers Telecommunicationsapplications Medical analysis equipment such as MRI and CAT scannersLaboratory instrumention Mission critical customized applications

Energy SavingCompared with traditional UPS, which efficiency less than 90% about10% is wasted. Fuhrer inverter efficiency is about 96%. It is designedfor lower heat emission, less energy waste.

Hot SwappableHot swappable module can be added or removed online. There is no needfor technical personal to perform the job . It is safe and convenient formaintenance and repair as no need to bypass the UPS.

Parallel SystemFuhrer modular UPS has the characteristics that it has the independentpower and control sections. Each module is an dependent UPS. Itadopts the centralized multiple parallel N+X format. It's simple forsystem expansion with little fault points. It provides load with N+1 toN+X levels of protection. The maximum can be expanded to 100kva.

Easy ExpansionWith the upgrade of customers' load requirement the original designedUPS may not be able to meet the demand. According to the traditionalUPS system, we must replace with a new and higher capacity UPSsystem for customers. But for Fuhrer modular UPS there is no need toreplace the whole UPS, but only adding the required number of modulesfor expansion, it saves customer's costs for initial equipment purchasingand future expansion.

Green PowerThe level of harmonic pollution of fuhrer is very low, input currentTHD<2%, Input PF above 0.99, This reduces more pollution to mainand power loss than equipment traditional UPS.

MODULAR ONLINE DOUBLE CONVERSION UPS (Fuhrer Series)

Page 47: XL SERIES - Delta Technologies

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

TECHNICAL SPECIFICATION

MODEL

RACK

MODULE

VoltageVoltage RangeFrequency RangePower FactorBy-Pass Range

THDi

10, 20, 30 & 40 KVA Max.

380 / 400 / 415VAC, (3PH + N + PE)208 - 478VAC

40 - 70Hz> 0.99

220 (+25% - 45%), 230 (+20% - 45%), 240 (+15% - 45%)Frequency ± 10% Hz

2% (100% Non Linear Load)

380 / 400 / 415VAC (3PH + N + PE)± 1%

1Line Mode ± 1% ~ ± 10% of __ Rated Frequency

Battery Mode ± 0.1% Hz3:1

<2% With Linear Load, <5% With Non Linear Load95.5%

± 216VDC / 240VDC

6A ~ 10A (Depending on Battery Capacity)

OMSLine Mode : <110% 60min, 125% 10min, 150% Switch to Bypass

Battery Mode: < 110% 30sec, 125% 1 sec, 150% System TripBypass Mode: Depending on Breaker Rack

USB, RS232, RS485, DRY CONTACT, INTELLIGENT SLOT.

0-40C0-95%(non-condensing)

<65 dB

Safety: IEC / EN62040-1, IEC / EN60950-1EMC: IEC / EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,

IEC61000-4-5, IEC61000-4-6, IEC61000-4-8Noise: EN62040-2

BATTERY

GENERAL FEATURES

MODULAR ONLINE DOUBLE CONVERSION UPS (Fuhrer Series)

FS-10100

10KVA~100KVA

FS-10200

10KVA~200KVA

FS-300

300KVA

FS-300

520KVA

INPUT

OUTPUTVoltageVoltage RegulationPower FactorOutput Frequency

Crest FactorHarmonic DistortionEiffeciency

VoltageChanging Current (Rack)Module

Transfer TimeOverload

Communication InterfearENVIRONMENT

Oprating TrendHumidityNoice Level

FS 1030

10 ~ 30KVA

PHYSICAL840 x 600 x 400 152Kg1100 x 600 x 2000 290Kg600 x 1100 x 2000 307Kg1200 x 860 x 2000 860Kg

FS 1030 ~ FS 101000FS 10200FS 300FS 510

10 KVA =20 KVA =30 KVA =40 KVA =

STANDRADS

18 30 60 100 130

3U (443 x 580 x 131)3U (443 x 580 x 131)3U (443 x 580 x 131)3U (443 x 580 x 131)

26Kg31Kg33Kg36Kg

MODULERACK====

Page 48: XL SERIES - Delta Technologies

SOLO SINEWAVE HYBRID INVERTERWITH BUILT-IN AVR

1KVA/2KVA

Solar Hybrid InverterHome & Small Office Loads

SOLO SINE

Page 49: XL SERIES - Delta Technologies

TECHNICAL SPECIFICATION

DP E

lect

roni

cs (D

euts

che

Pow

er C

o., L

imite

d)

SOLO SINE Series Domestic & Solar LoadsSmart House With SOLO SINE Hybrid Inverter With Built-In AVR

Features

Applications

SOLO SINE HYBRID INVERTER

Tube LightTVComputersFanStereoPABXRouterSwitch etc.

Deutsche Power SOLO SINE Series is a solar hybrid Inverter systemwith built-in AVR for home and office appliances. With PureSInewave its selectable wide and narrow input voltage switchfeatures flexibility for users. It is perfect to connect either domesticand office appliances or computer-related devices. Its a greensubst i tut ion for generator wi thout a i r po l lut ion .

MODEL

RANGEINPUT

OUTPUT

SOLO 1000

S ing le Phase In & S ing le Phase Out220V/230/240±25%

50Hz±5%

Pure S ine Wave220V/230V/240±10%

50Hz±1% (Battery Mode)<10msecUniversa l

12VDC 24VDC10A or 20A

SOLO 2000

1000VA / 600W 2000VA / 1200W

PhaseVoltageFrequency

Wave fromVoltageFrequencyTransfer TimeSockets

VoltageCharging Current

BATTERY

SOLAR CHARGERCharging CurrentSystem voltageOperating voltage rangeMax. PV Array open circuit voltage

30A12VDC

15~18VDC40VDC

24VDC30~32VDC

60VDC

(PV)Solar Specification

Pure Sine Wave Inverter4 Step AVRSelectable input voltage range for homeappliances or personal computersSelectable battery types of gel. lead-acidand open lead acid (optional)Selectable charging current : 10A or 20AAuto restart while AC is recoveringOverload and short circuit protectionGenerators & Computer-related devicescompatibleCold start function