XL-PBW350C-RGWO
EOC master + ONU
Optical receiver
User’s Guide
Contents
1. Preface ....................................................................... 3
2. Introduction ................................................................ 4
2.1 Product Introduction ........................................ 4
2.2 Product Feature ................................................ 5
2.3 Specification .................................................... 5
2.4 Port Explanation............................................... 8
3. Hardware Introduction ............................................... 9
3.1 Machine introduction ....................................... 9
3.2 Right side of machine ...................................... 9
3.3 Left side of machine ....................................... 10
4. Installation ............................................................... 10
4.1 Equipment Installation ................................... 10
4.2 Connection cable Installation ......................... 10
4.3 Check up after Installation ............................. 12
5. Schematic Diagram .................................................. 15
6. WEB network management ..................................... 17
6.1 System Management ...................................... 17
6.2 Card Management .......................................... 28
6.3 Slave Management ......................................... 32
6.4 System Log Management ............................... 38
6.5 System Software Management ....................... 39
6.6 Configuration Management ........................... 41
7. Typical Application .................................................. 43
1. Preface
Statement
The information in the manual may be changed at any time
without prior notice. The company does not make any guarantee
for it, and it is not responsible for the mistakes in this document
and the incidental any damage because of supplying or using this
manual.
The ownership information in this manual is protected by
copyright law. The company reserves all rights. It’s forbidden to
photocopy and copy this information, or translate it into other
languages without the written authorization from XTENDLAN.
2. Introduction
2.1 Product Introduction
Cab. Link system data optical station is the product that
integrates optical receiver, EOC master and ONU together. The
optical TV signal from HFC is sent to the optical receiver. The
optical Eth signal is sent to ONU, And then RF and Eth signal are
modulated into the mixed signal output, it means 2 fiber input, 1-
4 RF output. Hybrid master is like a small optical station with
high integration, excellent performance. And it’s suitable for new
network transformation.
2.2 Product Feature
◆ High performance optical receiver, 1- 4 channels high
electrical level output, the plug-in type equalization and
attenuation control which is general type and easy to test.
◆ Optical AGC control function, it will sure the electrical level
won’t change when the input optical power within -7~+2dBm.
◆ High performance ONU
◆ High integration, there are multiple signal integration,
unnecessary to install the signal mixing unit outside hybrid
master
◆ Flexible configuration, 1,2,3,or 4 RF output(optional), and
there is a test port for electrical level at each RF output port.
◆ Support AC220V or 60V(independent 60V port), and support
power pass over RF port
◆ It can be used with amplifier and divider together
2.3 Specification
Optical Receiver
Work wavelength 1100nm~1600nm
Receive range of
optical power
-7~+2dBm
Output electrical level ≥108dB(4 RF output)
Optical link
characteristic
CNR≥51dB,CSO≤-62dBc,CTB≤-65dBc
( 59 Channels, -1dB receive signal
test)
Reflection loss of
output port
47~860MHZ ≥16dB
Electrical level at the
monitor port
-20 dB(Relative to the electrical level
of RF output port)
Equalization
47~862MHz attenuation-type
equalization,(1dB optional)
Attenuation 0~20dB, (1dB optional)
Isolation with DATA Each RF port≥65 dB
EOC
Channel frequency 7~67.5MHz
Modulation mode
OFDM BPSK QPSK
16/32/64/128/256/512/1024/2048/4096
QAM
The number of subcarrier: 2880
Physical layer data 500Mbps
rate
MAC layer data rate 300Mbps
Work mode at MAC
layer
CSMA/CA
Output Power ≥120dBμV
Receive Sensitivity 25-30dBμV
No of maximum slave 253 pcs
Security 128-bit AES data encryption
VLAN IEEE802.1Q (VLAN lagging)
Management Support SNMP, local WEB or TELNET
Eth connector RJ45 port
ONU
RX 1490
TX 1310
Received optical
power
-24dBm ~ -3dBm
Transmitted optical
power
-2 ~ +4
Speed rate 1.25G(uplink and downlink)
Optical input port SC/APC,meet IEEE802.3ah standard
Eth port Four 10/100/1000BASE-TX RJ45 ports
Others
Connector F type Female
Insertion loss ≤1dB
Impendence 75ohm
Power supply 220V/60V
Power consumption
of whole machine
≤20W
Dimension 255mm*240mm*130mm
Operating Temp. -20℃~+70℃
Relative Humidity Less than 95%
Gas pressure 70kpa~106kpa
No causticity gas, no dust, no magnetic field disturb
In the real operation, there is no filter noise problem. when
working at -20℃~+70℃, no hang.
2.4 Port Explanation
Fiber IN: TV and Eth fiber input
OUT 1:TV and Eth Output
OUT 2:TV and Eth Output
OUT 3:TV and Eth Output
OUT 4:TV and Eth Output
F.O.T1: OUT1 and OUT2 level detection port
F.O.T2: OUT3 and OUT4 level detection port
FOR ATT1: OUT1 and OUT2 link attenuation
FOR ATT2: OUT3 and OUT4 link attenuation
FOR EQ1: OUT1 and OUT2 link equalization
FOR EQ2: OUT3 and OUT4 link equalization
ACP1,ACP2,ACP3 and ACP4: RF Power Supply Controller
Note: All RF ports support to pass 60V power, but power input
port need be AC60V IN. If the user needs 60V power pass again
over RF ports(OUT1, OUT2, OUT3 and OUT4 ) for the other
equipments in the behind, please plug in RF Power Supply
Controller at respectively ACP1, ACP2, ACP3 and ACP4 as
shown in the diagram. It’s default not to install power controller,
and they are supplied as accessories and packaged in the box.
3. Hardware Introduction
3.1 Machine introduction
Equipment use the medium-sized rain proof aluminum case. The
surface is sandblasted, heat dissipation and good shielding.
3.2 Right side of machine
On the right of hybrid master,it offer 2 or 4 channels mixed signal
output ports. If 2 output ports, and then provide 1 test port(-
20dB); If 4 channels output, and then provide 2 testing
ports(-20dB), Each testing port is used for 2 mixed ports.; 2 Fiber
input port, one is for ONU, another is for optical receiver.
3.3 Left side of machine
On the left of hybrid master,it offer one 60V or 220V power
supply port.
4. Installation
4.1 Equipment Installation
Please prepare all the necessary tools and cable before installing.
This equipment can be put in any place where has the enough
space. It is suggested that it’s installed in indoor and outdoor
frame, cabinet or metope.
4.2 Connection cable Installation
4.2.1 Power Supply
Power supply is subject to your purchased equipment. Equipment
power supply modes are 220V and 60V local power supply.
4.2.1.1 220V or 60V by the local power supply
220V: Insert 220V connector into power socket
60V: Connect AC60V port to RF port of power supply by the
coax cable. According to network design, configure the
corresponding RF power supply controller(ACP1,ACP2,ACP3
and ACP4). Use the standard Metric/English F type coax
cable.When connect the joint, tighten the joint exactly to confirm
connector to plug in the correct position and close connection.
Please check whether equipment operates normally after power
installation is completed. If there is trouble please switch off
power immediately for the detailed inspection.
4.2.1.2 60V power supply by the coaxial cable
Connect AC60V port to RF port of power supply by the coax
cable, check up to insert the corresponding RF power supply
controller and assure to use the standard Metric/English F type
coax cable. tighten the joint exactly to confirm connector to plug
in the correct position and close connection.
Please check whether equipment runs normally after power
installation is completed. If there is trouble please switch off
power immediately for the detailed inspection.
4.2.2 CATV optical signal input
CATV optical signal input is available by just connecting the
pigtail fiber on WDM directly to optical receiver. Please carefully
confirm the model of pigtail fiber connector and fiber connector
on optical receiver, to ensure matching. Please carefully clean
pigtail fiber connector when insert it, ensure that CATV signal is
stable and reliable.
4.2.3 IP optical signal input
IP optical signal input is available by just connecting the pigtail
fiber on WDM directly to ONU. Please carefully confirm the
model of pigtail fiber connector and fiber connector on optical
receiver, to ensure matching. Please carefully clean pigtail fiber
connector when insert it, ensure that IP signal is stable and
reliable.
4.2.4 TCP/TP signal input
Connect EOC master to ONU by Eth RJ45 port. When hear a
click, the connection is finished correctly.(This master has been
connected well when delivery).
4.2.5 The mixed signal output
With the coaxial cable, connect hybrid master to the coaxial cable
network, and ensure to use the standard Metric/English F type
coax cable (or cable directly into master output). According to the
network design requirements, use the corresponding RF power
supply controller, make 60V pass over RF ports so as to ensure
the normal operation of the active equipments behind.
4.3 Check up after Installation
4.3.1 Port Status
Hybrid master provides 1 AC60V( or AC220V) port, 1 fiber
input port, 4RF output port and 3 level monitoring ports.
4.3.2 LED Explanation of EOC Master Module
LED Color Explanation
Pwr Green Power supply is normal
Cab Green Data is being transmitted
LED Color Explanation
Eth1-2
Always
green
Eth port is connected normally
Green
flash
Be transmitting data
Off Eth port isn’t connected or error
EOC Master controls the connection status:
Verify all access devices have been established the effective
connection. EOC master module monitors the connection status of
every port. If any equipment is properly connected to EOC master
(Cable), and is transmitting signal, the indicator light of the
corresponding port will be ON.
4.3.3 LED Explanation of ONU
LED Definition Status Explanation
Pwr
Power
Supply
Indicator
Always
green
Power supply is normal
Green
flash
Power supply isn’t normal
Off
Sys System Green System is running
running flash normally
Off
System isn’t running
normally
Reg
Optical
registration
status
Always
green
ONU is registered to OLT
successfully
Off
ONU isn’t registered to
OLT successfully
Act
Optical
signal
indication
Always
green
Optical port detect the
signal
Green
flash
Optical port is sending or
receiving data
Off No signal at optical port
Lan1~
Lan4
Eth port
indication
Always
green
The internet is connected
Green
flash
Eth port is sending or
receiving data
Off The internet is connected
4.3.3 LED Explanation of Optical receiver
There are a rows of 10 LED light which show the current
received optical power.When input optical power is within
+1~-6dBm, it will ensure the output level won’t change. When
input optical power ≥+1dBm or ≤-6dBm, optical AGC function
isn’t in control.
5. Schematic Diagram
Optical receiver test
The machine should be good grounding (grounding
resistance less than 4 Ω).
The machine power supply can be offered by four RF
output and AC60V input port.
According to power supply requirement in the network,
insert RF power supply controller(ACP1,ACP2,ACP3 and ACP4)
into the corresponding position(OUT1, OUT2, OUT3 and OUT4).
The user could configure power supply pass over RF port
according to the real situation.
Optical AGC range of this machine is +2 ~ -7dBm. The
output level won’t change as long as the optical power in this
range.
After power supply, when the input optical power, then a
row of the power indicator light will directly display the current
input optical power.
According to the electrical level(TV signal) requirement
designed in network, adjust attenuation and equalization. FOR.
ATT1 and FOR.EQ1 simultaneously controls the equalization of
RF output port 1-2; FOR. ATT2 and FOR.EQ2 simultaneously
controls the equalization of RF output port 3-4. So every mixed
RF output port meet network requirement.
When optical receiver range is +2 ~ -7dBm, the output
electrical level is stable, the use don’t need to adjust it again. The
maximum electrical level of this hybrid master is 108dBuv, it’s
suitable to use in the new CATV bi-directional network. The
allowance will be high if providing too high electrical level. For
example, there are about more 100 subscribers under one optical
receiver, every RF port support about more 30 subscribers, the
electrical level is about 75dBuv, the allowance still is high in this
situation. If the electrical level of optical receiver is too high, it
will affect IP data(MER,BER,etc.). We advice the electrical level
don’t be more than 108dBuv.
The engineer need test the equipment according to this
manual. This hybird master use plug-in attenuation and
equalization design, so it is convenient to test for the engineer.
6. WEB network management
6.1 System Management
Regarding IP address, please see the label to stick on master. The
default system name and password both are admin. Connect
master to PC by Eth port, click IE browser, input IP address to
login WEB interface.
Note: When master is restored to the default settings, the IP
address is 192.168.1.6
6.1.1 System Management
Showing the current software version, IP address and MAC
address of master.
Note: It’s default not to provide Current Temperature function,
please indicate when order.
Function Explanation: The current software version is the
running software currently in the master system, and master IP,
subnet mask, gateway, SNMP information, MAC address in the
Eth layer, and in the coaxial layer.
6.1.2 Master Flow Statistics
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Flow Statistics.
Function Explanation: Master flow statistics shows the
receiving and sending data information, and obtains
communication information of the Ethernet layer by the number
of the received and transmitted bytes and the number of packets.
6.1.3 Master Network Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Network.
Enter the master network management interface, the user can set
master IP address and management Vlan. Input IP address, subnet
mask and gateway, and click Set. The settings would be effective
after rebooting.
Function Explanation: IP address must be unique, otherwise it
will lead to IP conflict. After setting IP address successfully, login
again by IP address in IE browser. The master must be connected
with vlan switch when management Vlan takes effective, and
then the user can manage master by it. This function helps the
clients to manage Eoc equipments.
6.1.4 Master Function Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Function.
Enter the master function management interface, the user can set
Loopback Detection enable, Active learning enable, the slave
permission to access master, loopback detection automatic
recovery enable, SSH enable and command configuration cycle,
then click "Set". SSH enable and command configuration cycle
will be effective after rebooting master.
Function Explanation: When enable Loopback Detection, the
slave will send outgoing broadcast packet automatically to detect
whether there is loopback at its ports. If has loopback the slave
will be set as the unauthorized one and all ports of the slave will
be blocked, so won't cause broadcast storm; The slave won't send
outgoing broadcast packet automatically if not enable Loopback
Detection. It will cause broadcast storm when the slave is
loopback.
When Active Learning enable is set as Active learning and
Active learning gateway by default, master would send outgoing
Active learning packet automatically, and so as to let ONU,
SWITCH, ROUTER in the upper layer to learn our master as
quickly as possible; When close Active learning enable, our
master won't send outgoing ARP packet, the time of learning our
master by ONU, SWITCH, ROUTER in the upper layer depends
on their learning time.
Slave Permission To Access Master means to control the
permission of slave to access master, so to ensure master safety
and stability. The function need be used with MAC filtering
enable together, namely need open MAC filtering enable
simultaneously.
Loopback Detection Automatic Recovery Enable, master
would automatically set slave as “Authorization Status” in the
white list; If disable this function, the user need set the
authorization status of slave manually when slave loopback is
restored.
SSH Enable, the user could login master by SSH protocol. But
the system booting would be slower, and this configuration will
be effective after restarting. The function can’t be used when
SSH Disable.
Command configuration cycle: when telnet login equipment,
and not any operation for at least 60 seconds, it'll exit from telnet
automatically.
6.1.5 Master Port Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Port Management.
Enter port management interface, it display all ports’ Work mode,
Port Enable, Connection Status and Flow Control Enable, when
the user want to change the configuration, click Set to enter the
configuration interface.
Configure Work Mode, Port Enable and Flow Control Enable. If
the user wants to check the configuration, please click Back or
Port Management.
Function Explanation: Work Mode set the work status of this
port, such as 10M/full duplex, 100M/full duplex or 1000M/half
duplex; Port Enable indicates to open port or close port; Flow
control function settings of the master need be the same with the
equipment connected to this master, such as ONU or fiber media
converter. Only unify the flow control configuration on master
and the opposite equipment to achieve it.
Note: Please note don't close the port you are using, otherwise
the communication between master and slave will be
disconnected.
6.1.6 Master Broadcast Storm Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Broadcast Storm.
Enter into Broadcast storm configuration interface, could configure
broadcast storm suppression information. After open suppression
enable, configure the suppression number, click Set.
Function Explanation: While opening suppression enable, can
suppress broadcast packet and multicast packet simultaneously.
6.1.7 Port Mirroring
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Port Mirroring.
Enter into Port Mirroring interface to configure this function.
When open port mirroring function, the user could change the
source port, the source port direction and the destination port.
Click Set to complete the configuration.
Function Explanation: When enable Port Mirroring, the user
could check all data packets of the source port from the
destination port.
6.1.8 ACL Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items ACL Management.
IP Filtering only allows the certain IP range to login all interfaces
of master by master’s Eth port.
Function Explanation: When enable IP Filtering, only allow or
forbid IP address in the certain IP range (decided by IP address
and subnet mask) to login all interfaces of master by master’s Eth
port.
MAC Filtering
Could add and delete MAC address
Click Add to enter the settings interface:
In this interface, you could add MAC address, and could choose
Filter Type.
Function Explanation: Enable MAC Filtering, the data frames,
whose the destination MAC or the source MAC existed in MAC
filtering table, would be limited to forward at the master side and
slave side.
Protocol Filtering
Could add and delete protocol.
Click Add to enter the settings interface:
The user could add the protocol type, and the format is four hex
integer, for example: 0x88e1.
Function Explanation: Enable Protocol Filtering, the protocol
which existed in protocol filtering table, would be limited to
forward at the master side and slave side.
6.1.9 Trap Management
Instruction: Click System Management in the longitudinal left
side, and then in horizontal items Trap Management.
Enter into Trap IP management interface to manage Trap IP
(Modify, add and delete).
Function Explanation: It's effective to manage Trap sending
destination by this function. When enable this function, master
would send a Trap to this IP and automatically inform the real-
time situation of master and slave when there is a Trap.
6.2 Card Management
6.2.1 Check network status of all connected slaves
Instruction: Click Card Management in the longitudinal left
side, and then in horizontal items Slave Online List.
Show the link information of all slaves connected with this
master, includes attenuation, SNR, RX, TX, software version, the
supplier’s information, the channel number, and the online time
of the slave. If there are many slaves, you could display the
slaves by sorting card.
Note: If master only provide 1 channel CAB signal, it’s
unnecessary to choose the card, because there is only one main
card. This function is used for multi-card master. One card
indicates one master module.
Function Explanation: Can know the slave bandwidth at TX
and RX (unit: Mbps), and the current software version.
6.2.2 The white list information under master
Instruction: Click Card Management in the longitudinal left
side, and then in horizontal items White List Info.
Check each configuration of the white list and the online status.
Click MAC address to change its white list configuration or
delete this MAC address from the white list.
Function Explanation: Can know the slave information by the
white list. And the slave can work correctly after it’s authorized.
6.2.3 Add White List
Instruction: Click Card Management in the longitudinal left
side, and then in horizontal items Add White List.
Choose the card which need add the white list, and then input
MAC address, click Add.
Function Explanation: The slave could communicate with
master after be joined in the white list.
6.2.4 Card Upgrade
Instruction: Click Card Management in the longitudinal left
side, and then in horizontal items Card Upgrade.
Set IP address of FTP server (Ensure FTP server has been
installed in PC and put the upgrade file into the shared folder of
FTP server, the username and password both are admin). To
ensure the upgraded software version is not the running one in
the system. Choose the upgraded file name, IP address of FTP
server and the card you plan to upgrade, Click Upgrade. Please
note the prompt while upgrading and check whether it’s upgraded
successfully.
Function Explanation: Provide the precondition for the
equipment upgrade.
6.2.5 Card Function Management
Instruction: Click Card Management in the longitudinal left
side, and then in horizontal items Card Function Management.
Choose the card you need set, and set its SNID, RF out power
and End Frequency.
Note: End frequency is convinent for the customer who want to
use work frequency 7.5-30MHz. And support 100Mbps
bandwidth in this frequency range.
6.3 Slave Management
6.3.1 Service Management
Instruction: Click Slave Management in the longitudinal left
side, and then in horizontal items Service.
The user can add, change and delete the service.
Function Explanation: Provide the rate-limiting and priority
configuration for the slave by Service Management. So it’s
unnecessary to configure the rate limiting and priority for each
port, just need choose the corresponding service.
6.3.2 Vlan Pool Management
Instruction: Click Slave Management in the longitudinal left
side, and then in horizontal items Vlan Pool.
Function Explanation: Choose the port which need set Vlan
Pool, choose Enable, and set the minimum and maximum value
of VLAN ID. Click Set to finish the configuration.
Note: If enable Vlan Pool, the system would prioritize the slave
configuration who’s Vlan is from Vlan Pool.
6.3.3 Slave Business Management
Instruction: Click Slave Management in the longitudinal left
side, and then in horizontal items Slave Business.
Function Explanation: Choose slave MAC which need be set
the business, click Check. It will display the detailed
configuration interface. The first item is Port Status of the slave,
including Connection Status, Work Mode, Vlan Mode, Vlan ID
and Flow Information.
The second item Slave Configuration, the user could set Port
Enable, Port Mode, Work Mode, self-loop Enable, Flow Control,
Service Name, Port Priority, Vlan ID and the slave whole
bandwidth.
The third item Broadcast Storm to enter its configuration
interface.
The fourth item Firmware Upgrade to enter its configuration
interface.
The fifth item Reboot to reboot the slave.
6.3.4 Wireless Management
Instruction: Click Slave Management in the longitudinal left
side, and then in horizontal items Wireless Management.
Function Explanation: If the slave connected with master
supports WIFI function, Eth 4 and WIFI of slave have VLAN ID
by default. If the port mode of Eth1-3 is Access, Vlan ID of Eth 4
and WIFI need be removed here; If the port mode of Eth1-3 is
Transparent, it’s unnecessary to do configuration here. But
VLAN ID of Eth 4 and WIFI need be removed by other
equipments, such as the upper SWITCH.
Note: The default Vlan ID number of Eth 4 and WIFI is 43, and
can be checked at WEB interface of WIFI management, the step
as follow:
Network – Bridge – Bridge Setting – Business Type – Internet –
Vlan ID.
6.4 System Log Management
6.4.1 System Log Information
Instruction: Click System Log in the longitudinal left side, and
then in horizontal items System Log.
Function Explanation: To know the latest log information by
refreshing the log.
6.4.2 Set System Time
Instruction: Click System Log in the longitudinal left side, and
then in horizontal items System time.
After modifying the time, click Set to complete the settings.
Function Explanation: Update the time of master by check PC
time.
6.5 System Software Management
6.5.1 Reboot
Instruction: Click System Software in the longitudinal left side,
and then in horizontal items Reboot.
Function Explanation: Reboot master remotely by this button.
Master can be restored to the factory setting, and then master
will reboot again, and clear away the white list configuration,
port configuration (service vlan, Qos, rate limiting).
Management Vlan also be restored into the original state. Master
IP is 192.168.1.6.
6.5.2 User Management
Instruction: Click System Software in the longitudinal left side,
and then in horizontal items User Management.
Function Explanation: Mainly change password of Admin user.
6.5.3 System Upgrade
Instruction: Click System Software in the longitudinal left side,
and then in horizontal items System Upgrade.
Enter the software upgrade interface, can switch master software
version.
Master software upgrade:
(Install FTP server correctly, and ensure the upgraded file is
placed into the shared folder of FTP server, the username and
password both are admin.)
To ensure the upgrading software is not the running one in the
system, fill in the upgraded file name and IP address of FTP
server.
Click Upgrade. Please note the prompt while upgrading and
check whether it's upgraded successfully.
Function Explanation: Provide the precondition for upgrading
master and improving master functions. And switching software
function makes it possible to use two different softwares.
6.6 Configuration Management
6.6.1 Save
Instruction: Click Configuration Management in the
longitudinal left side, and then in horizontal items Save.
Function Explanation: Save all master configurations and won’t
be deleted if power failure.
6.6.2 Backup
Instruction: Click Configuration Management in the
longitudinal left side, and then in horizontal items Backup.
Function Explanation: Export the configuration template of the
certain master (Master IP, Management Vlan, the white list
information, the service information of the slave, the
configuration information of the slave) to the server, and then
transmit this configuration template to other master. It’s
convenient to operate equipment.
7. Typical Application
7.1 Diagram 1
7.2 Diagram 2