Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
XPOWER MANUFACTURE, INC. 220 Clary Ave., San Gabriel, CA 91776
PH: 626-285-3301 FAX: 626-285-3302
Email: [email protected] Website: xpower.ws
COMMERCIAL DEHUMIDIFIER
XD-125
OWNER’S MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
Table of Contents
INTRODUCTION ............................................................................................................................................................2
SAFETY INSTRUCTIONS.................................................................................................................................................3
ASSEMBLY & PARTS .....................................................................................................................................................4
SET UP/OPERATION .....................................................................................................................................................5
CONTROL PANEL ...........................................................................................................................................................6
CARE & MAINTENANCE ................................................................................................................................................7
- Cleaning the Air Filter .............................................................................................................................................7
- Replacing the Battery .............................................................................................................................................7
TROUBLESHOOTING .....................................................................................................................................................8
APDS-I...........................................................................................................................................................................9
WARRANTY ............................................................................................................................................................... 10
INTRODUCTION
The XPOWER XD-125 dehumidifier is a professional drying tool designed to maximize water extraction in a variety of temperature and humidity conditions. Perfect for water damage restoration jobs as well as other industrial applications; the XD-125 offers programmable humidity for optimal environment control.
Advanced Digital Control Panel Auto Water Pump Drain Hose
Efficient Motor Compact Design
Semi-Pneumatic Wheels Highly Durable Construction
Model # XD-125 SPECIFICATIONS
XD-125 WATER REMOVAL CAPACITY
125 pints/day (90°F, 90% RH)
76 pints/day at AHAM (80°F, 60% RH)
TYPE Standard Refrigerant (R410A)
VOLTS/HERTZ 115V/60Hz
POWER 7.3 AMPS
AIRFLOW 235 CFM
OPERATING RANGE 33°–100°F
UNIT WEIGHT/DIMENSIONS (WxDxH) 81 lbs. / 20” x 19” x 32”
COMPRESSOR TYPE High Efficiency Rotary Compressor
DRAIN HOSE LENGTH 20 ft.
POWER CORD LENGTH 25 ft.
FILTER High Airflow Filter (HAF)
HOUSING CONSTRUCTION Roto-Mold Polyethylene
WHEELS Shock Absorbing Semi-Pneumatic
DEFROST TYPE Hot-Gas Bypass
SAFETY CERTIFICATION ETL/CETL Certified
SAFETY INSTRUCTIONS
1. Always operate the product from a power source of the same voltage, frequency and rating as
indicated on the product identification plate. 2. Close supervision is necessary when any product is used by or near children, the elderly, or the infirm.
Do not allow children to use the appliance as a toy. 3. Do not operate this product with a damaged power cord plug. If the supply cord is damaged it must
be replaced by a qualified personnel or other similar qualified persons in order to avoid hazard. 4. To reduce the risk of electrical shock, do not expose the unit or flexible cord to moisture of any kind. 5. Switch off and unplug from the power socket when not in use, before assembling or before cleaning. 6. Do not place objects on the product or allow objects to obstruct the inlet or outlet openings, or
operate in close proximity to walls, curtains, etc. 7. The use of attachments or accessories not recommended or sold by the product distributor may
cause injury to persons or damage to property. 8. This product is intended for normal light commercial use only. 9. Do not attempt to dismantle the appliance. 10. Do not operate the appliance on a metal surface. 11. Do not use the appliance in artificially hot or humid conditions, or allow it to be used in any other
hazardous environment. 12. Do not clean the appliance with organic solvent. 13. This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
14. This instruction manual is an integral part of the appliance. It should be stored for safe keeping and must always accompany the appliance in the event of ownership transfer or for reference to by a service engineer.
DO NOT OBSTRUCT THE AIR INLET OR OUTLET
READ AND SAVE THESE SAFETY INSTRUCTIONS
WARNING! - TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS OR PROPERTY:
ASSEMBLY & PARTS 1. Your XD-125 Dehumidifier is fully assembled with the exception of the handle
2. Using a Phillips screwdriver, loosely attach each screw to unit. DO NOT TIGHTEN until all six screws have been fastened. (*You will experience some resistance as screws fit into housing).
3. Alternate diagonally between screws when tightening to ensure the best fit.
1. Metal Handle 5. Air Outlet Grill
2. Control Panel 6. Air Inlet Grill
3. Semi-Pneumatic Wheels 7. Power Cord
4. Water Hose Bracket 8. Water Hose
DO NOT dispose of any packaging until you have confirmed the appliance is operational. After removing the packaging, ensure the contents are intact and complete. In the unlikely event of missing parts, contact your retailer.
DRAINAGE OPTION:
When drying extremely humid spaces,
a plastic pipe with a diameter
larger than 6.7” can be attached
to the hood as shown for faster
purging.
SET UP/OPERATION
BASIC OPERATION GUIDE
1. Press button to turn unit ON (*30 second delay is normal if recently powered off)
2. Display shows Preferred Humidity Setting on Left and Current Humidity on Right
3. Adjust and to set preferred humidity level (90% to 26%)
4. Unit will run automatically, turning on and off to maintain desired humidity level
5. To run continuously press to below 26% until “CO” displays
6. Once job is complete, press button to turn the unit off. The water pump will automatically purge for 40 seconds to drain.
Always operate unit in an enclosed area, closing all
doors, windows and other pathways open to
external areas for maximum water removal
efficiency
Keep traffic through drying area to a minimum
Place the dehumidifier in the center of the room
away from walls and furnishings. (Fig. A)
Uncoil entire drainage hose on rear of unit. Place
open end of hose into a drain, bucket, or outdoors.
Ensure drainage hose is not restricted or kinked.
DO NOT elevate hose higher than 15 ft. above unit.
(Fig B)
Take care that water does not create a slip hazard. If
using a collection bucket check water level regularly.
READ ALL INSTRUCTIONS TO PREVENT SYSTEM DAMAGE
For proper operation, DO NOT obstruct the air inlets/outlets, or drainage hose.
WAIT 30 minutes after transporting unit to jobsite before switching ON to allow refrigerant system to
stabilize
DO NOT switch the power OFF by disconnecting power cord
WAIT at least three minutes after turning the power OFF to move unit.
FIG. A
FIG. B
CONTROL PANEL
1. ON/OFF: Power button turns the unit ON or OFF
2. DISPLAY: Left hand side indicates adjustable preferred humidity level, right side indicates current humidity. See #5 for reading time.
3. AND : Set to adjust humidity ranging from 90% to 26%.
*By pressing key to below 26%, “CO” displays, confirming setting to run the machine
continuously.
4. PURGE: Press to empty water from the pump reservoir. During normal operation the pump
purges automatically when reservoir is full (indicator light will illuminate). ALWAYS purge before
moving machine to avoid water spillage. The pump automatically purges for forty seconds after
turning unit off.
5. T TIME:
INDICATOR LIGHTS:
Purging: Light illuminates to indicate when unit is purging either automatically or after selecting manual purge button.
Defrosting: Flashing light indicates unit is defrosting. Once defrost is complete the unit begins to dehumidify again automatically.
Running: Light illuminates to confirm unit is plugged into an active power source.
Key Lock Function: Press both “T” and “P” for 2 seconds at the same time. Defrost light will illuminate to confirm the control panel is locked. Unlock by performing the same function.
1. POWER (ON/OFF)
2. DISPLAY
3. UP AND DOWN CONTROLS
4. PURGE
5. TIME
0000:00
HOURS MINUTES
Press “T” once to display current job working time.
To reset working time for new job hold “T” down for 5 seconds.
Press “T” twice (within 10 seconds) to display the total working hours for the life of the machine. *This time cannot be reset. It will start again from zero if total time exceeds display space.
CARE & MAINTENANCE - Cleaning the Air Filter
Regular cleaning of filters is highly recommended. The performance of the dehumidifier will be
greatly reduced if the filters become blocked.
- Replacing the Battery
1. Confirm the dehumidifier is turned OFF
and the plug is disconnected from power
outlet
2. Remove the filter as shown in the
diagram.
3. Using a vacuum hose and nozzle, vacuum
any debris from the filter.
4. Wash with warm water and a mild
detergent and allow to air dry.
5. Once the filter is fully dried, re-install.
1. Confirm unit is turned OFF and plug is disconnected.
2. Remove the screws in the four corners of the control panel.
3. Once the screws are removed, carefully lift the control panel to access the PCB.
4. On the PCB is a 6F22 9V battery. Remove the battery and replace.
5. Align the control panel back on the PCB.
6. Reinstall the four screws.
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Dehumidifier does not operate
No power to appliance Check connection to power source. “Running” indicator light should flash green if unit is connected to a functional power source.
Switch not turned on Press to switch on
E4 error is displayed Check drainage hose for blockages
Dehumidifier collects little water
Insufficient working time Allow more working time
Filter is blocked Clean filter
Low ambient temperature Increase ambient temperature
Condensation hose is blocked Check hose for restrictions
Dehumidifier is operating
but room is not drying
Doors and windows are open
Seal room from external areas
ERROR CODES
CODE EI E2 E3 E4
Error Message
Coil sensor
error
Humidity
sensor error
Low or no
refrigerant
Water pump fault or
blockage
WARNING! UNPLUG & POWER OFF BEFORE PERFORMING ANY MAINTENANCE
ATTENTION! CONTACT A QUALIFIED SERVICE AGENT FOR REPAIRS IN THE EVENT OF ERROR CODES
APDS-I (sold separately)
Uses combined power of XPOWER Air Scrubber (X-3500) and
Dehumidifier to remove moisture and contaminants from the air.
(ASK125) Air System Adapter
(8DH15) Ducting Hose
(X-3500)
Air Scrubber
WARRANTY
XPOWER 1 Year Limited Warranty covers the unit from defects in materials and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs. The POWER CORD and FILTERS are not covered by the warranty. Service In order to receive service or replacement parts under warranty, you must:
Call XPOWER Customer Service at 855-855-8868 or 626-285-3301 for a Return Merchandise Authorization (RMA) number and return instructions.
Have original proof of purchase.
Use original packaging or Industrial certified packaging method. The end user will be responsible to ship the unit (with the RMA number showing on the shipping label) to the XPOWER Service Department. Upon inspection, we will advise you of the repairs needed and the cost (if applicable). XPOWER will provide repair or replacement parts depending on warranty. This warranty applies only while this appliance is used in the United States.
WARRANTY REGISTRATION
Please complete and mail or fax for your product warranty. F or a multiple units, please list serial numbers on a separate sheet of
paper. Address: XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA
Tel: (626) 285-3301; Fax: (626) 285-3302
Company Name / Contact Person / Title
Address City
State / Province Zip Country
Phone Fax E-mail
Model # Serial #:
Date of Purchase / / Purchased From
Additional Comments / Suggestions