2001-Aug-15 Matt Newville Consortium for Advanced Radiation Sources University of Chicago / Advanced Photon Source XAFS: X-ray Absorption Fine- Structure Overview of XAFS and XANES XAFS experiment design: transmission and fluorescence Fe foil, FeO, Fe 2 O 3 , Fe in cytochrome-c Data Analysis overview Today: Lecture (1 hour) XAFS measurements at 20-BM in groups of 5 (~1 hour/group). Data Analysis on example and measured data. Tomorrow: XAFS measurements (if needed) Data Analysis on example and measured data.

XAFS: X-ray Absorption Fine-Structure

  • Upload
    walker

  • View
    113

  • Download
    10

Embed Size (px)

DESCRIPTION

XAFS: X-ray Absorption Fine-Structure. Matt Newville Consortium for Advanced Radiation Sources University of Chicago / Advanced Photon Source. Overview of XAFS and XANES. XAFS experiment design: transmission and fluorescence - PowerPoint PPT Presentation

Citation preview

Page 1: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

Matt NewvilleConsortium for Advanced Radiation SourcesUniversity of Chicago / Advanced Photon Source

XAFS: X-ray Absorption Fine-Structure

Overview of XAFS and XANES

XAFS experiment design: transmission and fluorescence Fe foil, FeO, Fe2O3, Fe in cytochrome-c

Data Analysis overview

Today: Lecture (1 hour) XAFS measurements at 20-BM in groups of 5 (~1 hour/group). Data Analysis on example and measured data.

Tomorrow: XAFS measurements (if needed) Data Analysis on example and measured data.

Page 2: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Spectroscopy: Measure energy-dependence of the x-ray absorption coefficient [either log(I0 /I) or (If / I0 )] for an atomic core-level electron of a selected element.

X-ray Absorption Spectroscopy

Measured x-ray beam intensities for I0 (left) and I (right)

Transmission Measurements:

Page 3: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Fine Structure (XAFS)

We’re interested in the oscillations in (E):

Page 4: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

absorption requires an available electronic state for the photo-electron.

X-ray Absorption: Atomic View

An atom absorbs and x-ray of energy E, destroying a core electron with energy E0 and creating a photo-electron with energy (E-E0). The core level is refilled and a fluorescence x-ray or an Auger electron is ejected from the atom.

For an isolated atom, (E) is a smooth function of energy.

No available state: No absorption bythat core level

Page 5: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

With another atom nearby, the photo-electron can scatter from the neighbor atom. The interference of the outgoing and scattered waves alters the photo-electron wave-function at the absorbing atom, modulating (E).

X-ray Absorption Fine-Structure Spectroscopy

The absorption probability (E) depends on the spatial overlap of the core-level and photo-electron wave-functions. The core-level is localized, so the overlap is determined by the photo-electron wave-function at the absorbing atom.

The interference of outgoing and scattered photo-electron gives the oscillations in (E)

Page 6: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Spectroscopy: Measure energy-dependence of the x-ray absorption coefficient(E) [either log(I0 /I) or (If / I0 )] of a core-level of a selected element

X-ray Absorption Spectroscopy: Why Bother?

Element Specific: Elements with Z>20 can have EXAFS measured at the APS.

EXAFS = Extended X-ray Absorption Fine-Structure

XANES = X-ray Absorption Near-Edge Spectroscopy

Valence Probe: XANES gives chemical state and formal valence of selected element.

Natural Samples: samples can be in solution, liquids, amorphous solids, soils, aggregrates, plant roots, surfaces, etc.

Samples do not need to be crystalline.

Low Concentration: concentrations down to 10 ppm for XANES, 100 ppm for EXAFS.

Local Structure Probe: EXAFS gives atomic species, distance, and number of near-neighbor atoms around a selected element..

Page 7: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

EXAFS: the fine-structure oscillations in (E)

The EXAFS Equation

where k is the photo-electron wavenumber:

The EXAFS results from an outgoing photo-electron scattering from a neighbor atom, and returning to the core atom to interfere with the core level:

Outgoing photo-electron

Returning photo-electron

Scattering from neighbor atom (amplitude and phase depend on Z of neighbor atom)

Page 8: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

The EXAFS Equation

The EXAFS Equation for 1 atomic site (no disorder)

Photo-electron scattering

Averaging over all atoms in the sample, which has a distribution of distances (including structural and thermal disorder) the EXAFS Equation becomes:

2 = mean-square disorder in R

This fairly simple equation allows us to model near-neighbor species - throughf(k) and (k) – and distance R, and coordination number N .

Page 9: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Measurements: Experimental DesignImportant points to consider for measuring XAFS are:

Monochromatic x-rays: Need x-rays with a small energy spread or bandwidth. ~1eV at 10keV

Linear Detectors: The XAFS (k) is ~10-2 or smaller, so we need a lot of photons (ie, a synchrotron) and detectors that are very linear in x-ray intensity (ion chambers).

Well aligned Beam: The x-ray beam hitting the detectors has to be the same hitting the sample.

Homogeneous sample: No pinholes, and having a uniform and appropriate sample thickness (for transmission) of ~2 absorption lengths.

Page 10: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Measurements: The Experiment

Energy Scanning: The beamline needs to deliver monochromatic x-rays that are tunable so that we can scan energy across the absorption edge. We’ll scan from ~200eV below to ~800eV above the Fe K-edge, like this: Pre-edge ( -200 to –20eV ): 5.0eV steps. Edge ( -20 to + 20eV ): 0.5eV steps EXAFS ( +20 to ~800eV): 0.05 A-1 (photo-electron wavenumber)

Counting statistics for Good Data: The EXAFS is fairly small, so (E) should have a noise level of about 10-3. That means we need to collect ~ 106 photons. Transmission mode: no problem ( ~108 photons/sec) Fluorescence mode: may be a concern.

Page 11: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Measurements: Transmission

For a concentrated sample (ie, most absorption is from the element of interest), XAFS is best measured in transmission.

We need to get enough transmission through the sample to get a decent signal in the ion chamber. With,

We adjust the sample thickness x so that

above the absorption edge. For Fe foil:

But: the sample must be uniform, and free of pinholes.

If a transmission experiment can be done, this is an easy measurement and gives very good data.

Page 12: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Measurements: Fluorescence

For dilute atoms (say, in solution, or at low concentration) , the matrix may absorb most of the x-rays, and we don’t get much change in transmission for the element we care about.

XAFS can also be measured by monitoring the characteristic fluorescence from the excited atom.

For Fe K-edge, we’ll measure the K fluorescence line at 6.40keV.

But: There will also be elastic and inelastic scatter that we don’t want:

The measurement is different, but we analyze the resulting (E) in exactly way the same as for transmission.

Page 13: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Fluorescence

X-ray Absorption X-ray Fluorescence

Incident x-ray is destroyed. Core-level electron destroyed.Photo-electron ejected from atom.

Higher energy core electron fills empty electron level, and ejects an x-ray of fixed energy.

K : L electron fills K hole

K : M electron fills K hole

Page 14: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Measurements: Fluorescence

To separate the K fluorescence line at 6.40keV from the elastic scatter at ~7.10keV, we’ll use a filterof Mn: with an absorption edge at 6.5keV, it will absorb the scatter much more than the Fe Kline.

To prevent too much Mn K from getting in the detector, we’ll use a set of slits.

Another common approach is to use a detector with energy discrimination to select the fluorescence line of interest.

Page 15: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Analysis I: Data Reduction

No matter how we measure (E), we’ll want to reduce this data to (k), where k is the photo-electron wave number (momentum):

1: convert measured intensities to (E).

2: subtract a pre-edge background and scale (E) to go from 0 to 1.

3: remove a post-edge smooth background function (E) to isolate the XAFS:

5: Model f(k) and (k) and analyze (k) to get distances R, and coordination number N .

4: weight XAFS and Fourier transform from k to R space.

Page 16: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Data Reduction

1: convert measured intensities to (E).

I0 I

Page 17: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Data Reduction

2: subtract a pre-edge background and scale (E) to go from 0 to 1.

Fit a line in the pre-edge region andFit a polynomial in the post-edge, and determine the edge jump.

Page 18: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Data Reduction3: remove a post-edge smooth background function (E) to isolate the XAFS: Fit a smooth polynomial spline

to the XAFS to remove the slowly varying (low-frequency) components of (E)

Edge Step

Page 19: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Data Reduction

4: weight XAFS and Fourier transform from k to R space.

The XAFS is multiplied by k2 and then multiplied by a smoothing window function to eliminate ripple from truncation of (k).

Because of the (k) term, the peaks in |(R)| are not at the interatomic distances, but are shifted down by ~0.5A or so.

Page 20: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

X-ray Absorption Near-Edge Spectroscopy (XANES) is one of the only techniques that gives a direct measurement of chemical state (valence state) of an element. In many chemical and environmentally relevant systems, the valence state is as important as the total concentration of an element.

XANES Analysis is somewhat more qualitative than EXAFS Analysis.

XANES: oxidation state identification

There is a shift of the absorption edge by ~3eV per formal oxidation state for Fe, and qualitative differences in line shape.

Page 21: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

Where and are the photo-electron scattering factors.

These are non-trivial functions, and we’ve calculated them using an Ab initio program called FEFF.

Once we have these, we can get and

XAFS Analysis II: Modelling (k)

The XAFS for a coordination shell is modelled using

Mean-square disorder in R

Amplitude reduction factor

Energy origin to define where

We’ll also adjust these parameters in the analysis:

Page 22: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Analysis II: Modelling (k) Sum over Paths

The XAFS for a coordination shell is modelled using

And we now Sum over Scattering Paths to get the full XAFS, withContributions from all neighboring atom types and distances:

Now and are calculated for each scattering path or coordination shell.

The Parameters N, R, are now extended for each Path.

We’ll use 2 to 4 paths for most of the analysis here.

Page 23: XAFS: X-ray Absorption Fine-Structure

2001-Aug-15

XAFS Analysis With G.I.Feffit

G.I.Feffit.lnk

To Start the XAFS Analysis Program, click on the G.I.Feffit icon:

The example data and analysis scripts are in C:\IFEFFIT\NXS\G.I.Feffit will start in that directory,

At the command line, type ‘cd Fe’ to move to the Fe subdirectory.

From the menus, pick File->Read Command File and Choose Analyze.iff.

Single Step through this script to see the steps involved in reducing raw dataAll the way to

The command file Fit.iff will define the FEFF paths and fit the first shell of Fe metal.