Chapter 18. xACP Optimization In this section, we will learn how to use the xACP optimizer. So far, we have discussed how to build an ACP PRJ in terms of the required network specific inputs. Here, we will look at the PRJ details as they apply to the optimization process. This section is divided into the following sub-sections: Preparing for Optimization: Input data validation, optimization targets/thresholds, cell-level optimizer configuration Running the Optimization: Network-level optimizer configuration including RF parameters, traffic type(s), budget constraints, and optimization weights. 18.1. Preparing for Optimization 18.1.1. Input Data Validation Before running the optimization process, it is very important to validate the accuracy of the ACP PRJ input data. The most important part of any xACP project is a complete and accurate set of data. While the users can check and validate the data in any order, the following sequence is recommended. ACP Consistency Check Once project import is complete the user should utilize the ACP Consistency Check to aid in verifying a complete project. ACP Consistency Check is invoked by selecting x-ACP > Consistency Check. As seen in Figure 18.1, “ACP Consistency Check - Physical Tab”, Figure 18.2, “ACP Consistency Check - Prediction Tab”, and Figure 18.3, “ACP Consistency Check - UMTS Tab”, the xACP consistency check is broken into three categories with several checks in each category as follows: 1. Physical a. Loaded Antenna Pattern - Checks that each sector has a valid antenna pattern assigned. b. Antenna Pattern Validity - Checks the validity of each antenna pattern by detecting if the horizontal or vertical patterns have multiple consecutive blank entries or 0 values. Mulitple consecutive blank entries or 0 values in the horizontal or vertical antenna pattern does not always mean the antenna pattern is bad but those with this issue should be checked via Edit > Antenna and viewing the pattern. c. Ground Elevation - Checks for the existence of ground elevation data for all sectors in the project greater than a user defineable value. d. Pa Power - Checks that PA power is greater than a user definable value. e. Mechanical Tilt between - Checks that mechanical tilt is between two user defined values. f. Antenna Height between - Checks that antenna height is between two user defined values. g. Electrical Tilt between - Checks that electrical tilt is between two user defined values. Incorrect ET values in antenna patterns are very common. h. Azimuth Sanity - Identifies sectors that belongs to same site and Tech-Band that are close or same in Azimuth 2. Prediction a. Sector missing Pathloss - Checks that every sector has an associated pathloss grid. Since antenna patterns are used to calculate pathloss when pathloss is not available from the prediction tool (ASSET, PEV, Atoll, etc), this can be a result of incorrect band or missing antenna as well as the pathloss/RSSI file not present for import. b. Sector missing RSSI - Checks that every sector has an associated RSSI grid. Possible reasons for missing RSSI grids include: missing pathloss grid, RSSI Deleted or not generated (can be generated on demand via x-Propagation menu). c. Sector has number of Best Server pixels < - Checks if any sector has a number of best served pixels less than a user defined value. d. Sector has number of Drive Data points < - Checks if any sector has a number of drive data points less than a user defined value. If drive data is not imported, every sector will fail this test. e. Sector Pixel Confidence - Checks that pixel confidence (Predictions vs. Drive Measurements - See the section called “Pixel Confidence Report”) mean delta is greater than 6 dB or standard delta is greater than 8 dB. 3. UMTS a. UMTS Parameters - Checks that Max. PA Power, CPICH Power, SCH Power, PCCPCH Power, SCCPCH Power, Noise Rise, Max. Noise Rise, Percentage of Loading, and Bad Erlang are within a user-defined range. b. Simulation Profile Existence - Checks that at least one Circuit Switched and one Packet Switched UMTS Simulation Profile exists. It is very important that the project contains an accurate representation of the on-air UMTS service mix. c. RAB Power Consistency - The higher the bit rate, the more power is needed to achieve it at a reasonable BLER (Eb/No). Checks that RAB powers are as follows: Chapter 18. xACP Optimization Table of Contents 18.1. Preparing for Optimization 18.1.1. Input Data Validation 18.1.2. Network Data Validation 18.1.3. Using Groups in ACP 18.1.4. Save Project for Optimization 18.1.5. Configuring Optimizable Parameters 18.1.6. Configuring the ACP Optimizer 18.1.7. Candidate Site Creation (GSM only) 18.1.8. Running the Optimizer

xACP Optimization

Embed Size (px)

Citation preview

Page 1: xACP Optimization

Chapter 18. xACP Optimization

In this section, we will learn how to use the xACP optimizer. So far, we have discussed how to build an ACP PRJ in terms of the required network specific inputs. Here, we will look at the PRJ details as they apply to the optimization process. This section is divided into the following sub-sections:

� Preparing for Optimization: Input data validation, optimization targets/thresholds, cell-level optimizer configuration

� Running the Optimization: Network-level optimizer configuration including RF parameters, traffic type(s), budget constraints, and optimization weights.

18.1. Preparing for Optimization

18.1.1. Input Data Validation

Before running the optimization process, it is very important to validate the accuracy of the ACP PRJ input data. The most important part of any xACP project is a complete and accurate set of data. While the users can check and validate the data in any order, the following sequence is recommended.

ACP Consistency Check

Once project import is complete the user should utilize the ACP Consistency Check to aid in verifying a complete project. ACP Consistency Check is invoked by selecting x-ACP > Consistency Check. As seen in Figure 18.1, “ACP Consistency Check - Physical Tab”, Figure 18.2, “ACP Consistency Check - Prediction Tab”, and Figure 18.3, “ACP Consistency Check - UMTS Tab”, the xACP consistency check is broken into three categories with several checks in each category as follows:

1. Physical

a. Loaded Antenna Pattern - Checks that each sector has a valid antenna pattern assigned.

b. Antenna Pattern Validity - Checks the validity of each antenna pattern by detecting if the horizontal or vertical patterns have multiple consecutive blank entries or 0 values. Mulitple consecutive blank entries or 0 values in the horizontal or vertical antenna pattern does not always mean the antenna pattern is bad but those with this issue should be checked via Edit > Antenna and viewing the pattern.

c. Ground Elevation - Checks for the existence of ground elevation data for all sectors in the project greater than a user defineable value.

d. Pa Power - Checks that PA power is greater than a user definable value.

e. Mechanical Tilt between - Checks that mechanical tilt is between two user defined values.

f. Antenna Height between - Checks that antenna height is between two user defined values.

g. Electrical Tilt between - Checks that electrical tilt is between two user defined values. Incorrect ET values in antenna patterns are very common.

h. Azimuth Sanity - Identifies sectors that belongs to same site and Tech-Band that are close or same in Azimuth

2. Prediction

a. Sector missing Pathloss - Checks that every sector has an associated pathloss grid. Since antenna patterns are used to calculate pathloss when pathloss is not available from the prediction tool (ASSET, PEV, Atoll, etc), this can be a result of incorrect band or missing antenna as well as the pathloss/RSSI file not present for import.

b. Sector missing RSSI - Checks that every sector has an associated RSSI grid. Possible reasons for missing RSSI grids include: missing pathloss grid, RSSI Deleted or not generated (can be generated on demand via x-Propagation menu).

c. Sector has number of Best Server pixels < - Checks if any sector has a number of best served pixels less than a user defined value.

d. Sector has number of Drive Data points < - Checks if any sector has a number of drive data points less than a user defined value. If drive data is not imported, every sector will fail this test.

e. Sector Pixel Confidence - Checks that pixel confidence (Predictions vs. Drive Measurements - See the section called “Pixel Confidence Report”) mean delta is greater than 6 dB or standard delta is greater than 8 dB.

3. UMTS

a. UMTS Parameters - Checks that Max. PA Power, CPICH Power, SCH Power, PCCPCH Power, SCCPCH Power, Noise Rise, Max. Noise Rise, Percentage of Loading, and Bad Erlang are within a user-defined range.

b. Simulation Profile Existence - Checks that at least one Circuit Switched and one Packet Switched UMTS Simulation Profile exists. It is very important that the project contains an accurate representation of the on-air UMTS service mix.

c. RAB Power Consistency - The higher the bit rate, the more power is needed to achieve it at a reasonable BLER (Eb/No). Checks that RAB powers are as follows:

Chapter 18. xACP Optimization

Table of Contents

18.1. Preparing for Optimization 18.1.1. Input Data Validation 18.1.2. Network Data Validation 18.1.3. Using Groups in ACP 18.1.4. Save Project for Optimization 18.1.5. Configuring Optimizable Parameters 18.1.6. Configuring the ACP Optimizer 18.1.7. Candidate Site Creation (GSM only) 18.1.8. Running the Optimizer

Page 2: xACP Optimization

i. Bit Rate <= 12.2k, RAB power >= -3 dB (relative to CPICH)

ii. 12.2k < Bit Rate <=128k, RAB power >= 3 dB (relative to CPICH)

iii. Bit Rate > 128k, RAB power >= 6 dB (relative to CPICH)

Figure 18.1. ACP Consistency Check - Physical Tab

Figure 18.2. ACP Consistency Check - Prediction Tab

Figure 18.3. ACP Consistency Check - UMTS Tab

Page 3: xACP Optimization

As seen in Figure 18.4, “ACP Consistency Check - OLAP Output” results are presented in OLAP view for ease of viewing.

Figure 18.4. ACP Consistency Check - OLAP Output

Path-loss/RSSI Validation

Display the RSSI spatial view for the entire network. This is the position-based received signal information that we imported either using the DM or the prediction PLOSS files. The RSSI can be displayed by first selecting the desired Tech/Band to be viewed in the Tech/Band Filter and then selecting Raster > RF > Measurements and Predictions > RSSI from the Layer Manager Display Tree as shown in Figure 18.5, “RSSI Display for All Cells in the Network”. For dual tech/band PRJs, view each tech/band individually by selecting the appropriate option from the Tech/Band Data Filter drop-down list.

Figure 18.5. RSSI Display for All Cells in the Network

Page 4: xACP Optimization

One or more cells can be selected or deselected by holding the CTRL key and clicking the left mouse button. If no cell is selected (e.g. clicking on the space between cells), then the entire data will be displayed as shown in Figure 18.5, “RSSI Display for All Cells in the Network”.

Figure 18.6. RSSI Display for Selected cells Only

Note

It is very important to click on a few cells and display their individual RSSI view one-at-a-time. This is to make sure that the PLOSS data is mapped to the correct cell, as shown in Figure 18.6, “RSSI Display for Selected cells Only”.

Important

When the user selects one sector for RSCP visualization xACP will use the prediction information for the sector for the display. When the user selects more than one sector xACP will use the N-Best analysis and display for each sector information based on the N-Best analysis. Based on the “N” selected by the user for the N-Best analysis, the information displayed in this case will vary. The larger the “N” selected by the user, the more information will display when more than one sector is selected.

Page 5: xACP Optimization

The user should also verify that Best Served areas appear to be realistic by using the “Color Pixels By Best Server” display as seen in Figure 18.7, “Map colored by best server”.

Figure 18.7. Map colored by best server

Pixel Information

The user may view detailed pixel information by selecting View > Spatial > Pixel Information or by simpling selecting the Pixel Information tool in the toolbar. As seen in Figure 18.8, “Pixel Information GIS Display” the user is presented with detailed Pixel Information. The Pixel Information display is capable of both a Dynamic and Static mouse mode. The top “x” readings for the pixel selected are displayed with the best RSSI for the

Page 6: xACP Optimization

pixel selected displayed closest to the cursor and others displayed successively further away from the cursor according to RSSI. The “x” number of Best Servers to display can be set in Tools > Options, Visualization tab (see Section 17.3.3, “Options”). Latitude, Longitude, Terrain Elevation, Clutter Description, and Traffic Demand are also displayed if the rasters are selected in the Layer Manager. A line is also displayed pointing to the serving sector and colorized according to n-best server.

Figure 18.8. Pixel Information GIS Display

Pixel Confidence Report

If drive measured data has been imported into the project, the user should utilize the Pixel Confidence Report to understand the error between driven and predicted data that has been imported. For a given sector the set of all pixels that belong to that sector and analyzed. Pixel confidence is computed for each pixel on a scale from 0 to 100. The sector confidence is the percentage of pixels with good confidence. The pixel confidence is computed by computing the absolute error between drive data and prediction data for each pixel and then weighting it by the prediction RSSI at that pixel. The confidence of drive data at a given pixel is very low if the error between drive data and predicted data is high and prediction is high.

The Pixel Confidence Report can be accessed by selecting x-ACP > Reports > Generate Pixel Confidence Report. When this menu choice is invoked the user is presented with a dialog wherein a Measured/Predictions Data Filter and a Confidence Threshold can be selected. See Figure 18.9, “Pixel Confidence Report Dialog”.

Figure 18.9. Pixel Confidence Report Dialog

If the “Filter Report by Threshold” check box is checked pixel confidence algorithm will eliminate pixels for which the pixel confidence is less the threshold translated. This has the effect of eliminating sectors with poor pixel confidence from the report. Reports are presented when the generation completes and can be viewed via View > OLAP Reports > ACP > Pixel Confidence Report.

1. Project_name.sector_confidence.txt - This file contains each sector that has both predicted and drive measured data, the number of driven pixels associated with that sector, the mean delta between the driven and predicted bins, the standard delta between the driven and predicted bins, and the calculated confidence level for that sector. See Figure 18.10, “ Pixel Confidence OLAP Report”.

2. Project_name.no_readings.txt - This file contains a list of sectors for which no drive measured data was found.

3. Project_name.no_predictions.txt - This file contains a list of sectors for which no predicted data was found.

Figure 18.10. Pixel Confidence OLAP Report

Page 7: xACP Optimization

Physical Data Validation

Next, display the cell level physical parameters by selecting Edit > Sector (Physical Tab) as shown in Figure 18.11, “Validating the Physical Parameters”. The ESD contains the hard and soft parameters for every cell in the network. These parameters can be modified through the GUI for each cell individually, for a cluster of cells, or globally (Select All). Note, only a single cells information can be displayed at a time. If multiple cells are selected, only parameters that are same for all selected cells will be populated (viewable).

In this section, we will validate the following:

� Status: Defaults to On Air. See Section 18.1.5, “Configuring Optimizable Parameters” for more details.

� Lat / Long: The geographical location of the selected cell

� Ground Elevation: The height above sea level of the selected cell

� Antenna Model: The antenna model (also called the Antenna Family) used at the selected cell

� Antenna Pattern: The radiation pattern of the antenna in use

� Site Band: The frequency band of the selected cell

� Electrical Down tilt: The electrical tilt in use, positive value refers to a down-tilt

� ET Requires Site Visit: Unchecked by default. See Section 18.1.5, “Configuring Optimizable Parameters” for more details.

� ET Requires Tower Climb: Grayed out by default. See Section 18.1.5, “Configuring Optimizable Parameters” for more details.

� Azimuth: The azimuth of the selected cell

� Mechanical Down-tilt: The mechanical tilt in use, positive value refers to a down-tilt

� Height AGL: The antenna radiation center

� ERP (CPICH Power): The effective radiated power (Pilot power for UMTS networks)

� Forward Link Total Loss: Total loss on the forward link

� Reverse Link Total Loss: Total loss on the reverse link

� TMA: Check if TMA is used on the selected cell. Checking this box will result in canceling the reverse link total loss. Not applicable to ACP PRJs.

� Parent Site: Site ID and the frequency band of the selected cells parent site

� Alternative Site Name: Displays the alternative name (if any)

� Alternative Sector Name: Displays the alternative sector name (if any)

� Sharing Physical: Displays the cell ID of other cell(s) sharing the same antenna.

� Antenna With: Typically this applies to dual band/tech cells sharing the same physical Dual-Band antenna.

� Min MT + ET: Defaults to -20. See Section 18.1.5, “Configuring Optimizable Parameters” for more details.

� Max MT + ET: Defaults to 20. See Section 18.1.5, “Configuring Optimizable Parameters” for more details.

Figure 18.11. Validating the Physical Parameters

Page 8: xACP Optimization

Dual Band/Technology Cells

As discussed earlier, the ACP module supports multiple bands and technologies in one ACP PRJ. Figure 18.12, “Validating the Physical Parameters (Dual Band/Tech PRJ)” shows the ESD for a dual band/tech PRJ:

Figure 18.12. Validating the Physical Parameters (Dual Band/Tech PRJ)

In ACP, cells with dual band/tech are represented as two different cells with same lat/long, height, azimuth, and mechanical tilts. They may differ, however, with regards to the antenna model, antenna pattern, site band and electrical tilts. The band and technology information is also available in the “General Tab” of the ESD, and it is stored in the “PRJ_name.network.site.CSV” file in the PRJ folder.

Note

The band and technology information is not editable.

Page 9: xACP Optimization

For the dual band/tech cells the following applies:

� Antenna Model: Same antenna model on both cells (if using Dual-Band antenna)

� Antenna Pattern: The pattern in use is for the selected cells frequency

� Site Band: This should be the frequency in use for the selected cells technology

� Electrical Tilt: This should be the correct value for the selected band

� Sharing Physical Antenna With: Displays the cell ID of other cell(s) sharing the same physical antenna.

18.1.2. Network Data Validation

Display the cell level network parameters by selecting Edit > Sector (UMTS/GSM Tab) as shown in Figure 18.13, “Validating the Network Parameters”. Here, we will validate the following (example below is for a UMTS network):

� Reverse Link:

� Maximum Allowed Noise Rise: This is the maximum possible noise rise a cell is allowed to reach.

� Noise Figure: Noise figure (NF) is a measure of how much a device (such an amplifier) degrades the signal to noise ratio for a given cell.

� Noise Rise: Noise rise is the reverse link noise rise calculated by the simulator (or imported simulation results) for a given cell.

� Forward Link:

� Maximum PA Power: Maximum PA power of the selected cell. The calculated ERP is also displayed.

� CPICH Power: The Common Pilot Channel power of the selected cell

� SCH Power: The average Synchronization Channel power. Synchronization channels are active only 10% of the time-slot, therefore, their average power is calculated using: SCH = 10% of (Max Primary-SCH + Max Secondary-SCH).

� PCCPCH Power: The average Primary Common Control Physical Channel power. The PCCPCH is time-multiplexed with SCH and is active 90% of the time-slot. It is calculated using:

PCCPCH

= 90% of Max PCCPCH

� SCCPCH Power: The maximum Secondary Common Control Physical Channel power.

� Power Allocated for All TCHs: Total power that can be allocated for traffic on the selected TCHs cell.

� AS Threshold: The active set threshold relative to the strongest pilot.

� Orthogonality Factor: Measure of isolation among different code channels from the same cell.

� Percentage of Loading: The loading is calculated as the ratio of “Actual assigned DL traffic power” to the “Total allocated DL traffic power”.

� Scrambling Code: The scrambling code assigned to the selected cell

� Multipath Profile: Choose from the available (Flat, Pedestrian, vehicular) multipath propagation profiles

� Soft Hand-off Loading: The maximum percentage of loading that can result due to primary users

� Maximum Loading: The maximum allowed loading on the selected cell

� Maximum Traffic Power: The maximum traffic power a RAB can have relative to Allocation Per User/RAB the CPICH power (absolute power in the case of a User)

Figure 18.13. Validating the Network Parameters

Page 10: xACP Optimization

Clutter Attributes Validation

Display the clutter attributes selecting Edit > Edit KPI Objective Settings > Clutter Settings, by selecting the Edit Clutter Attributes tool in the tool bar, or by double-clicking or right-clicking on the Clutter item in the Layer Manager side bar. Click on the appropriate technology tab. Validate the clutter specific weights and thresholds as shown in Figure 18.14, “Validating the Clutter Attributes” (example below is for a UMTS network):

� Weight: These are relative weightings per clutter type. The optimizer gives priority to pixels based on the weights they carry. The optimizer uses this info to decide which pixel gets preference when doing the optimization, so pixels with a higher clutter weight have a better chance to get better coverage and quality. These are not “dB” values.

� FL Threshold Ec: The forward link Ec threshold value (pilot coverage in dBm).

� Max RSCP: The Maximum Best Server RSCP allowed for the clutter above which the pixel is penalized with ACP's Max RSCP Objective Cost Function. This is used to control the coverage in an Outside Network Border clutter from improving.

� FL Threshold EcIo: The forward link Ec/Io threshold value (pilot quality in dB).

� Penetration Loss - The penetration loss in dB for each clutter type.

Figure 18.14. Validating the Clutter Attributes

Note

Currently, these values are not imported from the planning solution PRJ (ASSET3G, PEV, Atoll) like other parameters. Therefore, new ACP PRJs have DEFAULT values. If licensed for the User Management module then default values can be defined by the user. See Section 21.5, “Manage Default Clutter Attributes” for details.

Important

Optimi recommends that the user very carefully consider the pixel counts for the various clutter types (right click on the displayed raster in Layer Manager, select Generate Histogram) in defining these weights. Optimi further recommends that the weights for pixel types whose covered counts are 25% or more of the overall covered pixel count for any one project be no less than half (50%) of the highest clutter weight.

Tip

The user may also import clutter attributes from another project. See Section 20.1.1, “Import/Export Clutter Attributes” for details.

Page 11: xACP Optimization

Clutter Import Validation

It is very important that accurate pixel level clutter type information is available in the ACP PRJ (as explained in Section 17.3.6, “Import Clutter” earlier). To validate the clutter data import, click on the Layer Manager Display tree and select Raster > Physical > Clutter as shown in Figure 18.15, “Validating the Clutter Type Import”.

Figure 18.15. Validating the Clutter Type Import

Elevation Import Validation

It is very important that accurate pixel level terrain elevation (or heights) information is available in the ACP PRJ (as explained in Section 17.3.7, “Import Elevation” earlier). To validate the elevation data import, click on the Layer Manager Display tree and select Raster > Physical > Elevation as shown in Figure 18.16, “Validating the Elevation Import”.

Note

Edit > Edit KPI Objective Settings > Global Settings is used in conjunction with the “Site” option and the Auto Weight Adjustment option. See the section called “ACP Parameters (Optimization Categories and Settings)” for details regarding these features.

Note

Changing the background color (States map) to white may help to better visualize different clutter types.

Page 12: xACP Optimization

Figure 18.16. Validating the Elevation Import

Pixel Profile

The user has the option of viewing the pixel profile by selecting the Pixel Profile button located in the tool bar. As seen in Figure 18.17, “ The Pixel Profile Tool” this functionality automatically docks in the right pane of the Main GIS view and shows the user information regarding the pixel profile between two points as selected in the Main GIS.

Figure 18.17. The Pixel Profile Tool

Note

Changing the background color (States map) to white may help to better visualize different elevation ranges.

Page 13: xACP Optimization

Information presented includes:

� Origin Lat and Lon

� End Lat and Lon

� Distance

� Elevation Change

This information can be helpful in determining the reason behind certian RF propagation characteristics.

Traffic Demand Import Validation

It is very important that the desired traffic demand grid(s) are available in the ACP PRJ (as explained in Section 17.3.17, “Traffic Demand Grid” earlier). To validate the traffic demand import, click on the Layer Manager Display tree and select Raster > Physical > Traffic (Demand) and select the desired traffic map as shown in Figure 18.18, “Validating the Traffic Demand Import”. While the users can add multiple layers to the view, for validation purpose though, it is better to view one layer at a time. Verify all traffic demand maps, one at a time.

Figure 18.18. Validating the Traffic Demand Import

Note

Changing the background color (States map) to white may help to better visualize different traffic values.

Page 14: xACP Optimization

Figure 18.19. Layer Manager

Using OLAP Tables for Data Validation

Imported PRJ data can also be viewed/validated using OLAP Tables. OLAP Tables are available by selecting View > OLAP Table. Selecting the parameters of your choice from this menu will provide information in the OLAP Table format. OLAP Tables are very flexible and powerful, the user

Note

The “Layer Manager Tree” can be used to change the Opacity of available layers as shown in Figure 18.19, “Layer Manager”.

Page 15: xACP Optimization

can customize these as needed. These tables can be exported and saved in CSV, Excel, Word and HTML file formats. Figure 18.20, “Validating PRJ Data Using OLAP Tables” shows a Physical Sector Data OLAP Table.

Figure 18.20. Validating PRJ Data Using OLAP Tables

18.1.3. Using Groups in ACP

The groups in ACP are provided for organizing purposes. The users can create and assign different cells to different groups as needed.

While groups provide the ease of better managing a PRJ, they do not tell the optimizer what parameters to optimize. The idea is to use the groups while configuring the optimizer settings on a cell-level. Refer the example shown in the section called “Dual Band/Technology Cells”.

Groups Creation Tools

The user is provided with tools to create groups automatically if desired. These tools are:

� Generate Tech/Band Groups - Accessed through Tools > Generate Tech/Band Sector Groups. This utility creates Tech/Band Sector groups based on the Tech/Band assigned to each sector. These groups provide ease of setting attributes by Tech/Band combination.

� Generate Sector Status Groups - Accessed through Tools > Generate Sector Status Groups. This utility creates Sector Status groups based on the Sector Status assingned to each sector as seen in Edit > Sector > Physical tab.

� Generate Co-Located Technology Groups - This tool is accessed by selecting Tools > Generate Co-Located Technology Groups. When this tool is invoked, the user is presented with a dialog wherein the attributes, technologies, and Group Class name of the group to be created can be entered. See Figure 18.21, “ Generate Co-Located Technology Groups Dialog”.

Figure 18.21. Generate Co-Located Technology Groups Dialog

Once created, the Group Class and Groups created can be used to easily select sectors and/or sites via the Edit > Sector dialog as seen in Figure 18.22, “ Edit > Sector - Apply Co-Located Technology Group Filter”.

Figure 18.22. Edit > Sector - Apply Co-Located Technology Group Filter

Page 16: xACP Optimization

This provides the user with an easy method of selecting sectors and/or sites that have multiple technologies for the setting of certain attributes. As an example, once the groups are created, GSM sectors that are co-located with UMTS sectors can easily be selected and marked “Special Purpose” in the Edit-Site dialog so that GSM sites will not be removed in a GSM Site Selection optimization leaving only a UMTS site at that location.

� Generate Tech/Carrier Sector Groups - Accessed through Tools > Generate Tech/Carrier Sector Groups. This utility creates Tech/Carrier Sector groups based on the Tech/Carrier assigned to each sector. These groups provide ease of setting attributes by Tech/Carrier combination.

Manual Groups Creation

The Groups tab of the ESD allows the user to define groups of cells in the PRJ. Groups can be created or deleted by using the Edit Groups window as shown in Figure 18.23, “Edit-Sector - Creating Groups”. The Edit Groups window can also be accessed via Edit > Groups.

Figure 18.23. Edit-Sector - Creating Groups

Page 17: xACP Optimization

Each group in ACP belongs to a group class. The user must create a group class before adding group(s) in it. Both, the class and group, must be created before assigning them to a cell. By default, all ACP PRJs have a group class called “REGIONS” that has five groups defined in it. These default groups cannot be deleted; however their use is optional.

Groups and Classes are defined as follows:

� Class: A cell can be a member of more than one class.

� Group: A cell can be a member of only one group within a class.

To create a new class, simply enter a name in the top Name input field and click on the New Class button. This creates a class type and will be shown in the List of Classes frame. To add a group to that class, select it from the List of Classes frame and enter a name of a group in the bottom Name input field and click on the New Group button. Repeat this to add more groups to the same class. To delete a group, open the Edit Groups window and simply select the class or group to be deleted, click on the Delete Class or Delete Group button.

Groups Assignment

Once the groups have been created, the group assignment can be performed by simply selecting a cell (or group of cells) and choosing the desired group from the desired class and clicking on the Apply button as shown in Figure 18.24, “Edit Sector - Assigning Groups”.

Figure 18.24. Edit Sector - Assigning Groups

Page 18: xACP Optimization

The following methods can be used to assign groups to different cells:

1. One cell at a time (using “Select”)

2. A geographical cluster of cells (using “Select Pixels in a Polygon”)

3. Cells with some common properties (using OLAP Tables)

Figure 18.24, “Edit Sector - Assigning Groups” above shows the usage of methods 1 & 2.

Method 3 involves selecting sectors using the OLAP view. In the example seen in Figure 18.25, “ Configuring By-Sector Contraints Using OLAP” the Physical Sector OLAP view has been used to filter and select all GSM1900 sectors with Antenna Family = 7770_00. Edit > Sector, ACP tab is then invoked to set the Electrical Tilt as desired. See Chapter 4, OLAP Table Overview for details regarding the manipulation of OLAP views.

Figure 18.25. Configuring By-Sector Contraints Using OLAP

Tip

In order to change ACP constraints for sectors with multiple antennas, the sectors selected must have the same number of antennas. Sectors with the same number of antennas can be selected via OLAP by applying a filter to the Number of Antennas field in OLAP and using the select buttons in OLAP to select these sectors. Setting up constraints for different sectors can also be accomplished through the import of ACP Optimization settings. See the section called “Import/Export Optimization Constraints” for details regarding the Import/Export of ACP Optimization settings.

Page 19: xACP Optimization

18.1.4. Save Project for Optimization

Before proceeding with the optimization, it is very important that we save a copy of the unoptimized (or Baseline) ACP configuration. The optimization process updates the existing predictions as well as all the optimizable parameter values in the configuration files, so it is essential to preserve the baseline configuration before optimization. The images of Figure 18.26, “Saving the Baseline Configuration” and Figure 18.27, “ Copying the Baseline Configuration” illustrate the recommended steps:

Figure 18.26. Saving the Baseline Configuration

Page 20: xACP Optimization

Figure 18.27. Copying the Baseline Configuration

� Copy the Baseline configuration by right-clicking on the Baseline configuration in the Configuration Manager sidebar (or via File > Manage Configurations > Copy) and selecting “Copy” (sample directory shown in Figure 18.27, “ Copying the Baseline Configuration”).

� Enter a name for the new configuration.

� Select “Sector measurements / predictions, N-best Grids, and Traffic (Demand)” in the “Grid data to include” section of the Copy Configuration dialog.

� Select “Set source configuration as baseline configuration.

18.1.5. Configuring Optimizable Parameters

The network parameters that can be optimized are available in the ACP tab of the Edit > Sector dialog as shown in Figure 18.28, “Edit Sector -

Optimizable Parameters”. In this dialog, the user can set optimizable parameters on a per cell basis. Each optimizable parameter has a button or drop down menu next to it.

Figure 18.28. Edit Sector - Optimizable Parameters

Page 21: xACP Optimization

Dual Band/Technology Cells

The optimizable parameters of dual band/tech cells must be configured for each band or technology individually. While the users may choose any method to configure dual band/tech cells, it is recommended to utilize “Groups” to accomplish this task. Once the groups are created and assigned to appropriate cells, it becomes very convenient to edit and apply settings on a per group basis. For example, Figure 18.29, “Configuring Optimizable Parameters for Dual Band/Tech cells” shows a scenario where the GSM1900 cells are being configured to be optimized for the antenna type and electrical tilt. In this case, the following groups were defined:

� Group Class = TECH_BANDS

� Group Names (within the TECH_BANDS class) = GSM850 BAND, GSM1900 BAND, UMTS850 BAND

Next, cells were associated to different groups depending upon their respective band/tech.

Finally, the optimizable parameters were configured for each group separately. Exact details on how to configure each parameter are presented in the remaining Section 18.1.5, “Configuring Optimizable Parameters” sub-sections.

Figure 18.29. Configuring Optimizable Parameters for Dual Band/Tech cells

Page 22: xACP Optimization

Sector Status (Active/Inactive Sectors)

This feature allows the user to set certain sectors On Air or Off Air so that they will or will not be considered in optimization, reporting, and simulation functions. Additional choices include Candidate On Air and Candidate Off Air which are used in conjunction with the ACP “Site” option. See the section called “The “Site” Option (Site Selection)” for details on this feature. The Status setting is located in the Edit - Sector "Physical" tab "Status" drop down menu as seen in Figure 18.30, “Active/Inactive Status Drop Down”. The user is also provided with a Sector Status Physical GIS layer as seen in Figure 18.31, “ The Sector Status GIS View”. The n-best server grids are rebuilt automatically when one or more sector/sectors is changed from on-air to off-air or vice versa. As a part of this feature, in Tools - Options "RF Settings" tab (as seen in Figure 18.32, “RF Settings Tab”), the user can specify the use of Predictions, Drive Measurements, or Combined (Combined is available after smoothing or scaling) for all operations.

Figure 18.30. Active/Inactive Status Drop Down

Tip

The user can also create groups based on the sector status by selecting Tools > Generate Sector Status Groups.

Page 23: xACP Optimization

Figure 18.31. The Sector Status GIS View

Figure 18.32. RF Settings Tab

Page 24: xACP Optimization

Antenna Type Optimization

A cell (or a group of cells) can be configured for antenna type optimization by clicking on the button next to the Antenna Model field in the “ACP” tab of the Edit > Sector window. The user will be presented with the Antenna Model Optimization Range dialog as shown in Figure 18.33, “Antenna Type Optimization - Set Range Window”.

Figure 18.33. Antenna Type Optimization - Set Range Window

In the above case, only two antenna types are available to the optimizer (as a valid option) when optimizing the antenna type for the selected cells.

The “Pole Shared Antenna” check box when checked tells the optimizer that the sector shares a pole, not just an antenna, with the same band different technology sector that it is antenna shared with. The antenna must be shared and the pattern match or it won't apply.

Electrical Down-tilt Optimization

Note

The button next to the Antenna Model field can be used to manually change the current antenna assignment for the selected cell. Please remember, changing current antenna assignment will result in changing the current network configuration that would require updated RSSI information.

Tip

ALL available electrical tilts for both the existing antenna and any antenna selected in the Set Range dialog will automatically be selected and, as such, considered by the optimizer. The user can also choose to use “Select a Range of Items” in the Electrical Tilt Set Range dialog to limit the Electrical Tilts considered by the optimizer. It is NOT necessary to select the existing antenna in the Antenna Set Range dialog in order for the optimizer to consider all of the Electrical Tilts for the existing antenna.

Page 25: xACP Optimization

A cell (or a group of cells) can be configured for electrical down-tilt optimization by clicking on the button next to the Electrical Downtilt field in the “ACP” tab of the Edit > Sector window. The user will be presented with the Electrical Tilt Optimization Range window as shown in Figure 18.34, “Electrical Down-tilt Optimization - Set Range Window”.

Figure 18.34. Electrical Down-tilt Optimization - Set Range Window

Note the following in the Figure 18.34, “Electrical Down-tilt Optimization - Set Range Window” above:

� All selected cells are currently using the same antenna family (7770_00).

� All selected cells are currenly using the 7770_00 antenna family in the Antenna 1 position.

� All selected cells have the same # of antennas.

� These cells are going to be optimized for electrical down-tilt and the available (or valid) option is to choose a tilt from 0 to 9 degrees from the (7770_00) family.

� The user can opt to select a range of items that will be correlated to the appropriate patterns by the optimizer.

ET Requires Site Visit and ET Requires Tower Climb

Two check boxes are available in the Edit > Sector, ACP tab dialog so that the user can indicate the type of Electrical Tilt for the sector/sectors in question as seen in Figure 18.34, “Electrical Down-tilt Optimization - Set Range Window”. Some antenna's electrical tilt can be changed via remote control of a servo in the antennas (ET Requires Site Visit) where others are done manually on the antenna itself via a tower climb (ET Requires Tower Climb). “ET Requires Tower Climb” check box is grayed out by default until the “ET Requires Site Visit” is checked. Depending on the type of Electrical Tilt, the user will select one or both and the solution will add the dollar cost of the site visit and/or tower climb to the overall costs for the changes to the site in question if a site visit and /or tower climb was not already required for other changes.

Pole Shared Antenna

This check box allows the user to apply pole sharing to sectors that share the same physical antenna and pole. The sectors in question must share an antenna and the sectors must be using the same antenna pattern (Electrical Tilt). If not, it will fail, the box will be unchecked, and a message output to the log.

Tip

For multi antenna projects the user may set ET constraints by antenna model, regardless of the position of that antenna on the sector, by exporting optimization constraints and setting up the constraints as desired per antenna model. The file can then be imported back into xACP to set the constraints. Antenna model and antenna pattern are exported as a part of the optimization constraints file to aid the user. See the section called “Import/Export Optimization Constraints” for details regarding the import and export of optimization constraints.

Note

The antenna pattern (or antenna type) to antenna family mapping, which is required for electrical down-tilt optimization, is explained in Section 17.3.10, “Import Antenna Type and Electrical Tilt”.

Important

To optimize Electrical Tilt and not Antenna, it is not necessary to select the existing antenna for optimization. If the user desires to optimize Electrical Tilt and not Antenna, all sectors can be selected via the “Select All” button and “Optimize this variable” selected in the Set Range dialog for Electrical Tilt. All available electrical tilts for the existing

Page 26: xACP Optimization

Azimuth Optimization

A cell (or a group of cells) can be configured for azimuth optimization by clicking on the button next to the Azimuth field in the “ACP” tab of the Edit > Sector window. The user will be presented with the Azimuth Optimization Range window as shown in Figure 18.35, “Azimuth Optimization - Range Window”.

Figure 18.35. Azimuth Optimization - Range Window

Range Settings

� Relative - The valid optimization values are considered relative to the existing azimuth values.

� Absolute - The valid optimization values are considered absolute (regardless of the existing azimuth values).

� Minimum - The minimum setting to be considered.

� Maximum - The maximum setting to be considered.

� Increment - The increments to be considered.

� Minimum Increment - The minimum increment to be considered.

Select Action

� Edit Range Settings - Allows the user to edit the Range Settings (the default).

� Convert to Absolute Range - Allows the user to convert Relative values to Absolute values (based on the current setting for the sector).

� Convert to Relative Range - Allows the user to convert Absoute values to Relative values (based on the current setting for the sector).

This button gives the user the option of converting the Range Type from Relative to Absolute for Azimuth, Mechanical Tilt, and PA/CPICH Power as seen in figure Figure 18.35, “Azimuth Optimization - Range Window”. The change is accomplished by taking the following steps:

� Select Edit > Sector.

� Select the sectors for which the range is to be changed.

� Select the “Convert to Absolute Range” or “Convert to Relative Range” button. Range settings will be greyed out.

Figure 18.36. Change Range Type Example

antennas will be considered by the optimizer as a result.

Page 27: xACP Optimization

� Select “OK”.

� Select “Apply” in the Edit > Sector dialog.

In the example in Figure 18.36, “ Change Range Type Example” the Azimuth for the selected sector is 30°. The Range was set for +/- 30°, relative. When the Range Type is changed to Absolute, the correct values for 30°, +/- 30° (Absolute) are automatically populated. The provides the user with an easy method to set absolute ranges for these attributes based on relative ranges so that the optimizer will be restricted to an absolute desired range when multiple optimizations are run.

Mechanical Down-tilt Optimization

A cell (or a group of cells) can be configured for mechanical down-tilt optimization by clicking on the button next to the Mechanical Tilt field in the ACP” tab of the Edit > Sector window. The user is presented with the Mechanical Tilt Optimization Range dialog as shown in Figure 18.37, “Mechanical Down-tilt Optimization - Range Window”.

Figure 18.37. Mechanical Down-tilt Optimization - Range Window

Page 28: xACP Optimization

Range Settings

� Relative - The valid optimization values are considered relative to the existing azimuth values.

� Absolute - The valid optimization values are considered absolute (regardless of the existing azimuth values).

� Minimum - The minimum setting to be considered.

� Maximum - The maximum setting to be considered.

� Increment - The increments to be considered.

� Minimum Increment - The minimum increment to be considered.

Select Action

� Edit Range Settings - Allows the user to edit the Range Settings (the default).

� Convert to Absolute Range - Allows the user to convert Relative values to Absolute values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

� Convert to Relative Range - Allows the user to convert Absoute values to Relative values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

Height AGL Optimization

A cell (or a group of cells) can be configured for antenna radiation center or height AGL optimization by clicking on the button next to the Height AGL field in the “Physical” tab of the Edit > Sector window. Doing this will bring the Set Range window as shown in Figure 18.38, “Height AGL Optimization - Range Window”.

Figure 18.38. Height AGL Optimization - Range Window

Page 29: xACP Optimization

Range Settings

� Relative - The valid optimization values are considered relative to the existing azimuth values.

� Absolute - The valid optimization values are considered absolute (regardless of the existing azimuth values).

� Minimum - The minimum setting to be considered.

� Maximum - The maximum setting to be considered.

� Increment - The increments to be considered.

� Minimum Increment - The minimum increment to be considered.

Select Action

� Edit Range Settings - Allows the user to edit the Range Settings (the default).

� Convert to Absolute Range - Allows the user to convert Relative values to Absolute values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

� Convert to Relative Range - Allows the user to convert Absoute values to Relative values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

Height Options

� Synchronize Heights - Checking this checkbox for one or more sectors of a site will result in the optimizer considering only height changes wherein all sectors for that site will be at the same height.

ERP (CPICH for UMTS networks) Optimization

A cell (or a group of cells) can be configured for ERP (CPICH for UMTS networks) optimization by clicking on the button next to the ERP (CPICH) field in the “Physical” tab of the Edit > Sector window. Doing this will bring the Set Range window as shown in Figure 18.39, “ERP (CPICH for UMTS Networks) Optimization - Range Window”.

Figure 18.39. ERP (CPICH for UMTS Networks) Optimization - Range Window

Important

If the Synchronize Heights option is selected for one or more sectors of a site whose sectors are not all at the same height, the selection will be rejected when the “Apply” button is selected and the option automatically turned off. Height tolerance is +/- one foot (.3048 meters).

Height Optimization is not allowed for multi antenna sectors.

Page 30: xACP Optimization

Range Settings

� Relative - The valid optimization values are considered relative to the existing azimuth values.

� Absolute - The valid optimization values are considered absolute (regardless of the existing azimuth values).

� Minimum - The minimum setting to be considered.

� Maximum - The maximum setting to be considered.

� Increment - The increments to be considered.

� Minimum Increment - The minimum increment to be considered.

Select Action

� Edit Range Settings - Allows the user to edit the Range Settings (the default).

� Convert to Absolute Range - Allows the user to convert Relative values to Absolute values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

� Convert to Relative Range - Allows the user to convert Absoute values to Relative values (based on the current setting for the sector). See the section called “Azimuth Optimization” for details.

Maximum Radio Power (UMTS) Optimization

A cell (or a group of cells) in UMTS can be configured for Maximum Radio Power optimization by clicking on the button next to the Power Relative to CPICH field in the “UMTS” tab of the Edit > Sector window. Doing this will bring the Set Range window as shown in Figure 18.40, “Maximum Power Optimization - Range Window”.

Figure 18.40. Maximum Power Optimization - Range Window

Note

For UMTS networks always use “Relative” when optimizing the CPICH power.

Page 31: xACP Optimization

Range Settings

� Relative - The valid optimization values are considered relative to the existing azimuth values - only relative range is enabled for Maximum Radio Power Optimization.

� Minimum - The minimum setting to be considered.

� Maximum - The maximum setting to be considered.

� Increment - The increments to be considered.

� Minimum Increment - The minimum increment to be considered.

Import/Export Optimization Constraints

Optimi xACP includes the ability for the user to import and/or export sector optimization settings. This functionality provides the user with an easy means of repeating optimization settings and/or sharing them with other users of the same project. As seen in Figure 18.41, “ Import Optimization Settings” the user is provided with the ability to import two separate constraint files:

� ACP per Sector Flags, Settings, and Costs. The file is a .csv (comma separated values) file with the following fields:

� sector_name

� antenna_number

� antenna_model

� antenna_pattern

� optimize_antenna_model

� dollar_cost_antenna_model_change

� optimize_antenna_height

� use_absolute_range_antenna_height

� min_range_antenna_height

� max_range_antenna_height

� increment_antenna_height

� min_increment_antenna_height

� dollar_cost_antenna_height_change

� optimize_antenna_azimuth

Note

“sector_name” is a required field. The user may choose to import one or more of the other fields in each file.

Page 32: xACP Optimization

� use_absolute_range_antenna_azimuth

� min_range_antenna_azimuth

� max_range_antenna_azimuth

� increment_antenna_azimuth

� min_increment_antenna_azimuth

� dollar_cost_antenna_azimuth_change

� optimize_antenna_mTilt

� use_absolute_range_antenna_mTilt

� min_range_antenna_mTilt

� max_range_antenna_mTilt

� increment_antenna_mTilt

� min_increment_antenna_mTilt

� dollar_cost_antenna_mTilt_change

� optimize_eTilt

� use_range_eTilt

� use_absolute_range_eTilt

� min_range_eTilt

� max_range_eTilt

� increment_eTilt

� min_increment_eTilt

� dollar_cost_eTilt_change

� optimize_power

� use_absolute_range_power

� min_range_power

� max_range_power

� increment_power

� min_increment_power

� dollar_cost_power_change

� min_et_plus_mt

� max_et_plus_mt

� min_pa_power

� max_pa_power

� ACP per Sector Antenna Models. The file is a .csv (comma separated values) file with the following fields:

� sector

� antenna type

Figure 18.41. Import Optimization Settings

Note

For the Sector Antenna Models file each sector/antenna type combination is a distinct row.

Tip

For the latest format of the files, Optimi recommends exporting constraints from a project and modifying the exported file for import.

Page 33: xACP Optimization

Optimizable Parameters Validation

After setting all the optimizable parameters, use the “Layer Manager Display Tree” to verify your settings as shown in Figure 18.42, “Display Tree - Optimizable Parameters Validation”.

Figure 18.42. Display Tree - Optimizable Parameters Validation

Page 34: xACP Optimization

18.1.6. Configuring the ACP Optimizer

After configuring the optimizable parameters on a per cell basis, we are now ready to set these parameters on a network wide basis. The various optimization parameters windows are available by selecting xACP > Optimization > ACP as shown in Figure 18.44, “Optimization Parameters - ACP Tab”.

Figure 18.43. Running the Optimizer - xACP > Optimization

Page 35: xACP Optimization

ACP Optimization

In this dialog the xACP optimization parameters are configured as shown in Figure 18.44, “Optimization Parameters - ACP Tab”.

Figure 18.44. Optimization Parameters - ACP Tab

ACP Parameters (Optimization Categories and Settings)

Check the desired RF parameters that need to be optimized. One or more parameters can be checked at the same time.

Page 36: xACP Optimization

The “Site” Option (Site Selection)

The “Site” checkbox provides the user with a means of having xACP add sites to the network as a part of each iteration before performing ACP optimization to optimize Coverage, Quality, and Capacity. The algorithm evaluates the coverage, quality, and capacity of the selected network or networks and adds sites considering the sectors marked “Candidate On-Air” (see the section called “Sector Status (Active/Inactive Sectors)”) as part of the candidate sites. Sectors marked “On Air” are considered to be part of the current network. The algorithm will automatically target the Service Levels populated for each band/technology combination in Edit > Edit KPI Objective Settings > Global Settings and add sites to the network until the target Service Levels are reached. See Figure 18.45, “ Edit Global Service Levels Dialog”.

Figure 18.45. Edit Global Service Levels Dialog

The algorithm will automatically add a number of sites for each iteration such that all sites will be added if the target Service Levels are reached.

The user is provided with an “Evaluate Network” option so that the current Network Service Levels can be understood in setting the Global Service Level settings. See the section called “Evaluate Network” for details regrading the Evaluate Network feature.

If, for example, the user wishes to run Concurrent ACP/Site Selection for the entire network, all UMTS sectors should be marked “Candidate On-Air”. If the Network Evaluation dialog shows 93% SL for Ec, 20% SL for Ec/Io, and 100% SL for FL EbNo and RL EbNo, the user would set the Global Service Levels as seen in Figure 18.45, “ Edit Global Service Levels Dialog”. The user can then select which physical attributes will be optimized as well as the “Site” option. When started, the optimizer will add sites for each iteration and performs ACP before adding more sites in the next iteration. xACP will continue in this manner until the Global Service Levels are reached. When the optimization completes, sectors belonging to sites added to the network will be marked “Candidate On Air” and sectors belonging to sites not added to the network will be marked “Candidate Off Air”. In the Group Class defined, the user will find an “Existing” group as well as the Selected and Not Selected groups defined.

When using the “Site” option, the optimizer also considers the “Cost of Adding Candidate Site” as set in Edit > Site > Costs tab. Sites that are cheaper to add to the network will be preferred according the to cost matrix in Figure 18.46, “ Financial Costs Matrix”. If the “Cost of Adding Candidate Site” is the same for all sites (defaults to $1) it will have no effect on the optimizer.

Figure 18.46. Financial Costs Matrix

Note

The RF parameters check-boxes in this dialog apply to the entire network. Cell-level settings are applied using the Edit > Sector (Physical Tab) window as explained in Section 18.1.5, “Configuring Optimizable Parameters”.

Tip

The Global Service Levels default to 100%. Since most networks do not have Service Levels of 100% for all KPIs, leaving the setting at default will usually result in the optimizer adding all sites marked “Candidate On Air” to the network.

Important

The number of sites added for each iteration is based on the number of iterations populated by the user according to the formula # Sites Added/Iteration = Number candidate sites / (Number of iterations - 2). If, for example, 5 iterations are selected, approximately 33% of the sites will be added for each iteration. Optimi recommends using a number of iterations such that approximately 10% of the candidate sites will be added for each iteration. Benchmarking performed by Optimi shows that this will provide the best results while keeping optimization time to a minimum. Optimi also recommends using the Auto Weight Adjustment (checked by default) feature when using the Concurrent ACP/Site Selection feature. This option causes ACP to target the Global Service Levels so that both the ACP and Site Selection portion of the algorithm will be tagetting the same Service Levels.

Note

If the Capacity Layer option is selected and the Concurrent ACP/Site Selection is run, the optimizer will consider the capacity layer algorithm in adding sites to the network. This means that capacity layer site will automatically be preferred and thus added first to the network.

Page 37: xACP Optimization

Tilt Settings

The Tilt Settings button allows the user to specify settings that will restrict uptilt and/or force downtilt for sectors based on Overshooting Rank (see Section 23.4, “OSS Based ACP Reports” for details regarding the Boomer Status Report and Overshooting Rank). Also the automatic downtilt can be forced based on DCR stats, loaded from OSS.

Figure 18.47. ACP Tilt Settings Dialog

As seen in the user has the following options:

� Downtilt Boomers - Enables the automatic tilting and no uptilt for boomers feature.

� Threshold 1 - No uptilt (ET + MT) will be allowed by xACP for sectors whose Overshooting Rank (as viewed in the Boomer Status Report) is higher than this value.

� Threshold 2 - .xACP will force 2 degrees of tilt (ET + MT) on sectors whose Overshooting Rank (as viewed in the Boomer Status Report) is higher than this value AND whose Bad Coverage Threshold is below the translated value.

� Bad Cov. Threshold - Bad Coverage Threshold (as seen in View > OLAP Table > Network > UMTS > OSS Data) used in conjunction with Threshold 1 which sectors must be below for the forced 2 degrees of downtilt to be applied.

Azimuth Settings

The Azimuth Settings button allows the user to specify the minimum angle of separation between sectors of the same site. See .

Figure 18.48. The ACP Azimuth Parameters Dialog

Tip

Capacity can be set by sector in Edit > Sector > General tab Max Erlangs or in Edit > Site, Capacity tab. The optimizer will use whichever capacity limit it “bumps” into first. If the “Capacity at Tech/Band” option is checked in Edit > Site, Capacity tab, xACP will apply the max erlang value entered by the user to each Tech/Band associated with each site. If a single site has, for example, two GSM band, checking the “Capacity at Tech/Band” option effectively doubles the capacity for this site at the site level.

Important

The Cost of Adding a Candidate site can be set in Edit > Site, Costs tab.

Important

The Boomer Status Report must be invoked for the ACP Tilt Settings feature to work properly. If no Boomer Status Report is available, the feature will have no effect on the optimization outcome.

Note

Forced downtilt changes for sectors whose Overshooting Rank (as viewed in the Boomer Status Report) is greater than Threshold 2 will be forced to the top of the scheduled changes.

Important

The Minimum Angle of Separation setting takes into account the beamwidth of the antenna. This means that the angle translated will be the minimum angle between the two closest 3 dB points of adjacent sectors. For example, if a three sectored site has 80° beamwidth antennas (240° total) and the sectors are oriented equally around the site, a setting of 40° or more will prevent the Azimuths from changing other than a change that will move all three

Page 38: xACP Optimization

Height Settings

The Height Settings button allows the user to specify whether or not the optimizer should synchronize height settings. See Figure 18.49, “ The ACP Heights Parameters Dialog”.

Figure 18.49. The ACP Heights Parameters Dialog

Site Settings

The Site Settings button allows the user to specify the maximum number of sites to add when using the “Site” (Concurrent ACP/Site Selection) option as seen in Figure 18.50, “ Max # Added Sites Dialog”.

Figure 18.50. Max # Added Sites Dialog

Checking the box and specifying a maximum number of sites to add will result in the optimizer ceasing to add sites to the network once that number of sites is reached regardless of the Service Level.

$ Cost per change

This is the $ cost associated with each RF parameter change. The available $ amount is limited by the total $ Budget value. The overall objective function of the optimizer is a combination of RF and budget costs.

$ Budget

This is the total available $ budget allocated for the optimization session. A lower $ budget may result in limiting the total number of possible changes.

# Changes/Milestone

This is for administration purposes only. This value does not limit the number of changes the optimizer can make. It simply divides the total number of changes by the value entered in the #Changes/Milestone field such that each milestone (group of changes) results in a net improvement to system performance. For this reason, Optimi recommends that recommended changes be implemented in complete milestones only.

For example, using a value of 30 in the #Changes/Milestone field means that the “AcpChangesScheduleAggregate” report will get a maximum of 30 changes per milestone. If in the example of 30 Changes/Milestone, the optimizer comes up with a total of 100 changes, now the report should have the following:

� Milestone1 = 30 changes

� Milestone2 = 30 changes

� Milestone3 = 30 changes

� Milestone4 = 10 changes

Run Schedule Changes

This check-box should be selected if the user desires that the Aggregate Schedule file be created. The schedule generator groups the changes into those that require a site visit (Azimuth, MT) and those that do not require a site visit (ET, Power). It then finds the changes that provide the most positive effect on the system and do not require a site visit and schedules those changes first, grouped by site. It then moves on to changes that do require a site visit. In SLOW mode, this process is undertaken again to find the next best changes (once the first set are applied). This continues until all changes are considered. In FAST mode, the first order of changes is taken. For this reason, SLOW mode provides a more accurate schedule but can take many hours in a large project. SLOW mode is recommended

sectors the same amount in the same direction. This also means that a setting of zero will prevent sector overlap within the 3 dB points of the antenna pattern.

Note

The “Synchronize Heights” option must be turned on at the sector level for this setting to have any effect. See the section called “Height AGL Optimization” for details.

Note

The budget cost may be overwritten by entering large $ budget limit and small individual budget items (i.e., $cost/change)

Tip

If the user desires to run more than one optimization to experiment with different settings, it is recommended that Run Schedule of Changes NOT be selected until the final run. This will save time.

Page 39: xACP Optimization

Technology and Band

Select the appropriate PRJ technologies and bands. The ACP module allows the users to include sites of multiple technologies and bands in one ACP PRJ. However, as detailed in Section 17.3.8, “RF Data”, PLOSS data relevant to each technology and band must be present for each cell.

Technology/Band Traffic Grid

Here, the user can select the desired traffic demand grid from the drop-down list to be used while optimizing the network. For UMTS band/technology combinations the traffid demand grid is associated with the UMTS Simulation Profiles configured in Edit > UMTS > Simulation Profiles.

Use Capacity Algorithm (GSM)

This check-box allows the user to optimize both layers (bands) of a dual-band GSM network concurrently. When selected, the “other” band will be grayed out. The user must set the capacity and coverage layer bands via the drop down dialogs. The solution will load data from both bands. Where the best-server RSSI for the capacity layer band is >= the Capacity Layer Coverage Threshold setting for the capacity layer band (settable in Edit-Clutter Attributes), that capacity layer band will be assigned all of the traffic from that bin and the capacity layer band will be optimized. The coverage layer or “other” band will be ignored. Where the best-server RSSI for the capacity layer band is NOT met, the coverage, or “other” band will be optimized. This allows for optimization considering dual-band networks layered using Hierarchical Cell Structures. The user can exclude high frequency band sectors from the capacity layer rules by specifically assigning them to the coverage layer. This can be done from the Edit > Sector... window by clicking on the Coverage Sector option for the sectors of interest.

Sector Group Settings

The Sector Group Settings portion of the dialog provides the user with a means of defining the group class and group names for sites that are kept and sites that are removed as a result running a Concurrent ACP/SS optimization (see the section called “The “Site” Option (Site Selection)”). Sectors whose status is“On-Air” before optimization will be placed in a group name named “Existing” in the defined group class.

Evaluate Network

Selecting this button results in the xACP solution calculating the Coverage, Quality, Capacity and Dominance Service Levels for the band/technology combinations checked. The user is provided with a tab showing the Service Levels for each band/technology combination as well as an “All” tab as seen in Figure 18.51, “ The Network Evaluation Dialog”.

Figure 18.51. The Network Evaluation Dialog

The Service Levels presented are calculated using the Data Source as set in Tools > Options, RF Settings tab and include all sectors marked On Air or Candidate On-Air. If the user wishes to evaluate the network without Candidate On Air sectors, these sectors must be marked “Off Air” before invoking Evaluate Network The user can also initialize the optimizer by selecting “OK” (“Run Optimizer in Batch Mode” UNchecked) and note the values under “Initial” on the left side of the ACP Optimization Status dialog. See the section called “Sector Status (Active/Inactive Sectors)” for more details regarding sector Status.

The Objective Tab

Here the user can enter the technology specific optimization weights with relative importance given to coverage, capacity and quality. The set of weights displayed in the objective tab depends upon the number of technologies checked in the ACP tab. Each set of weight applies only to the labeled technology. Additionally, this window facilitates the inclusion of population, clutter and traffic data for optimization consideration as shown in Figure 18.52, “Optimization Parameters - Objective Tab”.

Figure 18.52. Optimization Parameters - Objective Tab

Note

Only band/tech combinations for which there are prediction, measured, and/or combined RSSI grids in the project will be available in the GUI for optimization.

Note

For multiple band or technology PRJs, the optimizer will search for the best combination of changes given that they impact both technologies/bands.

Page 40: xACP Optimization

Optimization Weights

These technology specific weights are relative values (unit less). A value of 100 for all is the same as a value of 10 for all. What is important is the relative difference between these weights.

For a new network, with no or minimum knowledge of the network performance, the user may start the optimization using equal weights for capacity, coverage and quality. After the initial optimization run, the user can refer the optimization results to get a much better feeling about the current performance of the network. At that point, the weights can be tuned as needed. For more details, refer to Section 19.5, “The Reports Tool”.

Large Cell Prevention - Traffic Growth %

The Large Cell Prevention - Traffic Growth % value provides the user with a method of preventing the optimization results from including very large service area sectors. When the optimizer is run on UMTS systems that have very low traffic, the resulting design can result in some sectors with a very large service area. This can occur because the optimizer is concerned only with coverage and quality (including traffic quality) taking into consideration the traffic demand grid set for optimization by the user. As traffic grows, sectors with a very large service area can become problematic. By populating a value in the provided box the user can quickly and easily limit the downlink loading for each sector based on its current Max Loading. This has the effect of evenly spreading the loading amongst the sectors and preventing large cell service areas. This is accomplished by setting the Max Loading for each sector according to the formula: Max Loading = Max Loading/(1 + growth/100). For example, if Max Loading is set to 50% for all sectors, setting a value of 100% for Traffic Growth will result in a Max Loading of 25% for all sectors. Using this feature the user can optimize a UMTS network while considering a unitform growth factor.

Calibration Options

“Iterations to calibrate” - This field is applicable for UMTS ACP and LTE ACP, it provides the user with a method of having the Optimi X solution calibrate the optimizer loading between iterations. When translated to a value > 0, the optimizer will run a simulation every “x” iterations in order to re-calibrate Forward Link Loading and uplink Noise Rise that has an impact in UMTS/LTE network quality and coverage for both uplink and downlink. This option can make the final-optimized system's coverage, quality, and capacity better. Benchmarking performed by Optimi indicates that the resulting improvement is typically very small and thus may not be worth the addition time it takes to run the simulator every “x” iterations.

x Population

Checking on the “x Population” check box allows the optimizer to prioritize pixels based on the population data imported using the Import > Traffic > Population Count. Pixels with a high population count will get priority in terms of receiving better coverage, capacity and quality.

x Clutter

Checking on the “x Clutter” check box allows the optimizer to prioritize pixels in different clutter types based on the Clutter weightings (as set in Edit > Edit KPI Objective Settings > Per Clutter Settings).

x Traffic

Checking on the “x Traffic” check box allows the optimizer to prioritize pixels based on the selected traffic distribution(s). The optimizer allows the user to optimize the network simultaneously for multiple traffic types that represent the different services offered to the network subscribers. For example, different services could be defined for voice users and Internet users, or for indoor users and outdoor users. This traffic distribution is:

� NOT used to calculate the interference resulting due to the network users (traffic).

� Used ONLY to weight pixels (differentiate between pixels) in terms of the traffic these pixels carry.

Note

The clutter specific thresholds (such as Ec, Ec/Io, Eb/No, etc. for UMTS PRJs) are always considered regardless of the “x Clutter” check-box being checked or unchecked.

Page 41: xACP Optimization

The optimizer uses this information to decide which pixel gets preference when doing the optimization, so pixels with relatively more traffic have a better chance to get better coverage and quality.

Dominance - Number of Servers and C/I Threshold

The Dominance section provides the user with a method of setting dominance criteria. The user is provided with fields to populate a Number of Servers and a Dominance threshold. The optimizer will consider bins that have less than the translated number of servers within the translated signal threshold of the best server to be covered from a dominance perspective. For example, if the user populates 8 servers and a threshold of 12 dB, any bin which has 7 or less servers within 12 dB of the best server will be considered to be covered from a dominance perspective. Using this option will prevent the optimizer from making changes that would result in the loss of a dominant server for the area in question and thus introducing a potential interference problem.

Use Neighbor Penalty

The Use Neighbor Penalty checkbox provides the user with a means of using the dominance settings to enforce a penalty when one or more of the “x” servers within “y” dB is not a neighbor. When the Use Neighbor Penalty checkbox is checked, xACP will generate the user-defined number of direct neighbors for each sector and use the dominance settings to apply a penalty for each bin where one or more of the “x” servers within “y” dB of the best server is not a neighbor. This feature has the effect of preventing large uptilts that can be problematic as system traffic grows.

UMTS Multi Carriers Options

UMTS Multi Carriers Options provides the user with a method of setting the coverage criteria for multi carrier UMTS optimization:

� At least one carrier has coverage - The optimizer will consider the bin covered if at least one carrier meets the coverage criteria.

� All carriers have coverge - The optimizer will consider the bin covered only if all carriers meet the coverage criteria.

Active Set Size

This value is the target Active Set Size for UMTS. The optimizer will seek to keep the Active Set Size at or below the translated value.

HSDPA CIR Target

This value is the target CIR for HSDPA enabled services. The optimizer will seek to keep the the CIR for HSDPA enabled services at or above the translated value.

LTE Options

The max IoT value is the maximum allowed level of Interference-over-Thermal (IoT) per sector before ACP starts penalizing due to excessive uplink interference. This IoT term penality prevents the uplink capacity from growing when increasing the coverage area if there is a degradation in the uplink quality. The IoT penalty is included as part of the uplink capacity penalty contribution combined together with the sector overload.

The Optimizer Tab

Clicking on the Optimizer Tab will display the window as shown in Figure 18.53, “Optimization Parameters - Optimizer Tab”.

Figure 18.53. Optimization Parameters - Optimizer Tab

Tip

Dominance Weight must be > 0 for the Use Neighbor Penalty feature to function correctly.

Warning

Like any setting that constrains the xACP optimizer, benchmarking performed by Optimi shows that the “Use Neighbor Penalty” option can result in sub-optimal results. While limiting large uptilts can be good for future system growth they are sometimes required for optimal system performance in the present. Optimi recommends that the user verify the project is complete by using the ACP Consistency Check (see the section called “ACP Consistency Check”) and add any expected growth to loading and/or demand grid values to be used for optimization.

Page 42: xACP Optimization

Number of Iterations

Enter the total number of iterations for the optimizer. The number of iterations needed for each PRJ will vary depending on many factors (# of parameters to be optimized, # and location of cells, etc.). Initially, you can start with a relatively lower number such as 5 or 10. When the optimizer is running, try to look at the relative improvement from one iteration to the next.

The idea is to note the improvement as the optimization proceeds. At some point, you will start seeing that more iterations are not helping in providing more improvement. At that point, you may choose to stop the optimizer. So, even if you have started the optimizer with 100 iterations to be done you may stop the optimizer at any time.

Speed of convergence

Here the users can pick from the following three options:

� Slowest

� Fastest

� Medium

The quality of the optimized solution is related with the speed of the convergence. Typically, fastest speed results in a lesser quality solution. The Fastest and Medium options can be used in the beginning of a PRJ to get a feeling of much improvement is taking place.

Run Optimizer in Batch Mode

By checking this check box the user can choose to have the optimizer run in “Batch Mode”. This will cause the solution to “Start” the optimization and commit the results automatically. This is helpful for extremely large projects wherein it can take up to two hours to reach the “Start” dialog.

Auto Weight Adjustment

By checking the “Auto Weight Adjustment” check box as seen in Figure 18.53, “Optimization Parameters - Optimizer Tab” the user can choose to have the optimizer automatically adjust the Coverage, Quality, and Capacity weights during the optimization process as it targets the Service Levels translated in Edit > Edit KPI Objective Settings > Global Settings. Selecting this option will result in the optimizer automatically adjusting the appropriate weight downwards as that particular target is approached. The weight adjustment is proportional to the distance from that particular target. This means that as one particular target is approached, the weight for that KPI is adjusted downwards so that proposed changes will be more beneficial to the other KPIs. This results in more balanced performance for the optimized system. This feature is especially useful for systems that are not well balanced as it relates to Coverage, Quality, and Capacity and is recommended when using the ACP “Site” option (see the section called “The “Site” Option (Site Selection)”).

Bias Search by Financial Cost

By checking the “Bias Search by Financial Cost” check box in xACP > Optimization, ACP tab as seen in Figure 18.44, “Optimization Parameters -

Important

When running ACP optimizations with out the “Site” (Concurrent ACP/Site Selection) option, the optimizer will automatically stop when convergence is reached. This means the user can translate a very large number of iterations and let the optimizer stop itself when convergence is reached.

Note

Before moving to the Objective Tab, make sure to click on “Apply” to save your settings.

Page 43: xACP Optimization

ACP Tab” the user has the option of forcing the optimizer to consider the changes with smaller dollar costs associated with them first. This will result in better performance when the optimizer is given a limited budget while also resulting in a larger dollar cost to achieve the best (unlimited budget) performance solution.

As a part of the Bias Search by Financial Cost feature, the user is provided with the ability to set a “% percentile accepted changes per dollar” limit in the Optimization Status dialog as seen in Figure 18.54, “ xACP Optimization Status Dialog - Financial Optimization Selected”. This provides the user with a method of telling the optimizer to accept only changes that make up a certain percentage of the overall budget translated by the user. Benchmark testing performed by Optimi indicates that for most ACP optimizations 75% or more of the overall improvement can be achieved using 50-60% of the budget. For example, translating this value to 50% will result in the optimizer applying only the most important changes that use only 50% of the budget.

Figure 18.54. xACP Optimization Status Dialog - Financial Optimization Selected

Optimi recommends using this option only when the user desires to use a limited budget rather than using an unlimited budget and employing the Schedule of Changes to pick a “cut off” point for changes to be applied based on dollar cost and/or cumulative performance improvement.

Incremental Changes

This option provides the user with a method of forcing the optimizer to explore smaller, incremental changes as it searches for the best solution. Benchmarking performed by Optimi indicates that this option can provide better results for large projects. Note that the Incremental Changes feature can also increase optimization times.

After setting all three tabs in the Optimization Parameters window, we are now ready to start the optimization. Click on “Apply” to save your settings. Next, click on “OK”.

For PRJs with some missing or incomplete data, the users may get the following window:

Also, consider looking at the Message Log, there might be warning messages as shown:

Tip

The cost for each type of change can be configured by sector. The “Bias Search by Financial Cost” will take these costs into account so that sectors with a lower dollar cost for a particular type of change will be considered first.

Important

The Incremental Changes option will only allow changes of +/- 2 degrees around the current value of the parameter. For this reason no changes will occur for attributes whose minimum increment value (Edit > Sector, ACP tab) is set to be larger than 2 when Incremental Changes is enabled.

Page 44: xACP Optimization

In such cases, update/modify your PRJ and start the optimizer again.

18.1.7. Candidate Site Creation (GSM only)

The user may choose to have xACP create potential candidate sites by selecting xACP > Candidate Site Creation. When this menu selection is invoked, the user is presented with a dialog as seen in Figure 18.55, “ The Candidate Site Creation Dialog”.

Figure 18.55. The Candidate Site Creation Dialog

The user may choose the GSM band to be considered in creating the candidate sites. The algorithm will add candidate sites midway between any sector with capacity problems (Carried Erlang > Maximum Erlang) and its neighbors. A minimum of 3 and a maximum of 8 sites will be created for each overloaded sector. Sites will be added starting with a location that is midway between the overloaded sector and its closest neighbor first. If no neighbors are defined, the algorithm will add the candidate sites starting midway between the overloaded sector and the closest site and work towards the furthest site from the overloaded sector until the maximum of 8 is reached. Candidate sites created will be created in the band selected in the drop down using the physical characteristics (height, antennas, azimuth, etc.) of the site whose sector is overloaded. If the site whose sector is overloaded is dual band (multiple bands tied to the same physical site), only sectors for the band of the overloaded sector will be created for the new site.

Sites and sectors are named “Added_x” where “x” is the number of the site added starting with 0.

The Candidate Site Creation feature creates a set of files in a “configuration_name.Candidate_Site” sub-folder found in the configuration folder. Files created are as follows:

� Candidate_Site-ReportGSM”Selected_Band” BAND.csv - File containing the Lat and Lon of the sites added.

� added_GSM”Selected_Band” BAND.wizard.tx - Wizard Transmitter file for import into xWizard via File > Import > Project Data in xWizard.

� added_GSM”Selected_Band” BAND.wizard.cel - Wizard Site file for import into xWizard via File > Import > Project Data in xWizard.

� added_GSM”Selected_Band” BAND.physical.site.csv - Physical site file in xACP format.

� added_GSM”Selected_Band” BAND.physical.sector.csv - Physical sector file in xACP format.

The files created can be used to import the created sites and sectors into the user's prediction tool and run predictions for import into the xACP project. Once the candidate sites and sectors are imported into the xACP project with predictions, the user may run the ACP “Site” option so that the optimizer can select the sites that best solve the capacity problems. See the section called “The “Site” Option (Site Selection)” for details.

18.1.8. Running the Optimizer

Automating ACP Functions

Manage Optimization Scenarios

In order to take advantage of ACP Batch Operations the user must first create Optimization Scenarios via Edit > Manage Optimization Scenarios. As seen in Figure 18.56, “ The Manage Optimization Scenarios Dialog”, the user may Add, Load, or Delete Optimization Scenarios. The user has the following choices:

� Add From Config - An Optimization Scenario will be created from the current configuration.

� Load Into Config - A previously added Optimization Scenario can be loaded into the current configuration.

� Delete - Delete Optimization Scenarios

Figure 18.56. The Manage Optimization Scenarios Dialog

Tip

Optimization scenarios consist of saved Global (ACP Opt Parameters), Sector, Clutter Attributes, and/or Simulation Settings. Optimi recommends setting up sector-level constraints and then using different global settings (x-ACP >

Page 45: xACP Optimization

ACP Functions

The user can use the Task Flow Manager to create and execute ACP Functions to ease the operations associated with xACP Optimization. The user can also choose to run ACP Functions Asynchronously to take advantage of multiple core computers by running multiple optimizations concurrently.

As seen in Figure 18.57, “ Task Flow Manager - Add, Edit Remove”, by selecting Tools > Task Flow Manager the user can Add, Edit, or Remove Task Flow templates. Templates may be added at either the User or Project level.

Figure 18.57. Task Flow Manager - Add, Edit Remove

Once the Task Template is created, the user can add the Copy Configuration and/or ACP Functions item to the Task Flow Template by simply dragging them to the Task Flow template name as seen in Figure 18.58, “ Task Flow Manager - Edit Task Flow”. The user may also choose to run the operations Asynchronously by checking the “Run Asynchronously” checkbox for the appropriate tasks.

Figure 18.58. Task Flow Manager - Edit Task Flow

For detailed information regarding the use of the Task Flow Manager, see the section called “Task Flow Manager ”.

As seen in Figure 18.59, “ Setting ACP Function Properties”, once the Task Flow template is created, the user can define the variables associated with the task as follows:

� Optimization Scenario - The Optimization Scenario to be used (see the section called “Manage Optimization Scenarios”)

� Source Configuration - The configuration that the optimization is to be run on (the configuration must exist).

� Target Configuration - The configuration name the optimization will use when saving the optimized configuration. If left blank, changes will be written to the source configuration.

� Run Simulator - Option to run the UMTS Static Simulator

� Generate GSM Statistics - Option to generate GSM statistics

� Generate UMTS Statistics - Option to generate UMTS statistics

� Run ACP - Option to run ACP

Optimization > ACP) to save Optimization Scenarios.

Page 46: xACP Optimization

� Run Scrambling Code Opt - Option to run SC optimization

� Generate LTE Statistics - Option to generate LTE statistics

� Generate WiMAX Statistics - Option to generate WiMAX statistics

Figure 18.59. Setting ACP Function Properties

The Optimization Summary window

The optimizer provides the following summary of the current optimization scenario:

Please, verify this info with your desired optimization goals.

KPIs Service Level warning

The optimizer will display a warning as shown in Figure 18.60, “ACP Optimization Service Level Threshold Warning” if KPIs for current configuration is 100%. It prompts the user to change corresponding thresholds so that optimizer can improve that KPI if that is the interest of the user. For example if “Percent Covered” in Optimization Dialog is 100% user can increase target “Coverage Threshold (dbm)” in “Edit Clutter Attributes” for GSM or “FL Threshold Ec(dbm)” for UMTS so that “Percent Covered” is not 100% and ACP will try to improve coverage for the network then.

Figure 18.60. ACP Optimization Service Level Threshold Warning

Important

The Task Flow User tool will execute the operations according the to the settings that are translated and applied in the various forms. This means that for the process to fully complete automatically, the “Run ACP in batch mode” option must be checked in xACP > Optimization, Optimizer tab. Optimization and/or Simulation will be performed according to the settings found applied and save in the chosen Optimization Scenario. Statistics will be generated using the settings the user employed (or saved via Apply and Save) when the statistics were run previously.

Page 47: xACP Optimization

The Optimization Status window

Next, the optimizer provides a status window. In this dialog can specify the following:

� % percentile accepted changes - The user can input a desired percentage of the total accepted changes to be applied. Since the optimizer applies the most important changes first, the final changes often result in minimal improvement. The provides the user with a method of leaving out the less significant changes. Benchmarking performed by Optimi indicates that for most projects 75-80% of the changes will result in 90% or more of the overall improvement.

� per dollar - By checking this box the user can specify a % percentile accepted changes per dollar. This provides the user with a method of telling the optimizer to accept only changes that make up a certain percentage of the overall budget translated by the user and is therefore most useful when employing the “Optimize Financial Cost” feature (See the section called “Bias Search by Financial Cost”). Benchmark testing performed by Optimi indicates that for most ACP optimizations 75% or more of the overall improvement can be achieved using 50-60% of the budget. For example, translating this value to 50% will result in the optimizer applying only the most important changes that use only 50% of the budget.

In the Optimization Status Window the user can also monitor changes in RF costs, monetary costs, and the percentage of covered and good quality pixels as shown in Figure 18.61, “Optimization Status Dialog”. Click on “Start” to initiate the optimization process.

While the optimizer is running, compare the following:

1. “Initial Cost” with the “Current Cost” and the “Best Cost”. The lower the cost the better it is.

2. Percentages: Improvement from Initial values to the current values.

3. Dollar Cost: Current Dollar cost should be zero for all parameters. This cost will increase with each change in the parameter values (as set in the RF Tab of the optimization window)

Figure 18.61. Optimization Status Dialog

The optimizer stops after finishing the user-defined number of iterations with the following message:

Alternatively, the user also has the option to click on “Pause” to stop the optimizer at any time while it is still running, as shown:

Note

The Optimi X solution will run the UMTS simulation according to the settings found in xACP > UMTS Simulation.

Note

If you currently have one or more GIS layers viewable (Clutter, Elevation, DM, etc.) you may want to either remove them or make them invisible by clicking on “View the Layer Manager” and un-check the “Visible” check-box. For networks covering large areas, this might result in increasing the speed of the optimization.

Page 48: xACP Optimization

Once the optimizer is paused, the user has three options, as shown:

Resume:

Start optimization from where it was paused.

Commit

Changes: Accept, save the optimization results, and exit the optimizer.

Cancel:

Ignore the optimization results and exit the optimizer

In cases where the optimization stops after completing all iterations, the window looks as follows:

In the above case, the user has only two options either save the results by clicking on Commit Changes or ignore the results by clicking on Cancel.

When committing changes, the user is informed that the PRJ will be saved automatically. This is a reminder, in case the user has not saved the “baseline” or unoptimized PRJ separately, the original network configuration will be overwritten.

After selecting “Yes”, if the “Run Schedule of Changes...” check box in xACP > Optimization, ACP tab was checked (see the section called “Run Schedule Changes” for details) before optimization was started, the user will be presented with a dialog showing the schedule of changes as seen in Figure 18.62, “ Schedule of Changes Dialog”. The '% Changes Applied' value in the textbox correlates to the selected changes on the screen and vice versa.

Figure 18.62. Schedule of Changes Dialog

Note

When the optimizer stops after completing all of the requested number of iterations, the “Iteration” field (total number iterations) in the status window goes back to zero.

Page 49: xACP Optimization

If the “Target SL Coverage” and “Target SL Quality” settings are left at the default of 100%, the Optimi X solution will, by default, check the changes such that total dollar budget is not exceeded and such that the final milestone is complete (no partial milestones - see the section called “# Changes/Milestone” for details regarding milestones). If the “Target SL Coverage” and/or “Target SL Quality” values are translated to something other than the default of 100% the Optimi X solution will seek to find a place in the list of changes that will fulfill those translated values and such that the final milestone is complete. If such a place in the list of changes cannot be found, NONE of the changes will be selected. In this case the user must select the changes he/she desires to be applied. Once “OK” is selected the selected changes are applied and written to the output files.

Note

When the user selects a particular change in the list, all changes down to and including that change will be selected. This allows the user to pick a place in the changes list above which all changes will be selected and applied when “OK” is subsequently selected.

17.4. Ready for Optimization Chapter 19. xACP Analyzing Results