30
X-Ray Absorption and Emission William I. Campbell, U. S. Department of the Interior, Bureau of Mines, College Park Metallurgy Research Center, College Park, Md. lames D. Brown, University of Western Ontario, Faculty of Engineering Science, london, Ontario, Canada s IK OUR 1964 (116) and 1966 (117) A reviews, we continue to use the format established by our predecessors Liebhafsky, Winslow, and Pfeiffer (413). This 1968 review consists of a critical evaluation of new developments and tabular summaries of X-ray spectrog- raphy and electron probe microanalysis. Stoddart and Dowden (614) recently compiled a comprehensive bibliography on fluorescent X-ray spectrography. Their bibliography is indexed by the element determined, matrix analyzed, author, equipment, method, and theory. At present the principal application of X-ray emission and absorption tech- niques is to determine the concentration of specific elements. In the future X-ray emission techniques will find ad- ditional applications as analytical chem- istry becomes more sophisticated in characterizing materials. The Com- mittee on Characterization of Materials, Materials Advisory Board, National Research Council developed the follow- ing definition (441) : “Characteriza- tion describes those features of the com- position and structure (including de- fects) of a material that are significant for a particular preparation, study of properties, or use, and suffice for re- production of the material.” Low- energy X-ray spectroscopy supple- mented by photoelectron and Auger spectroscopy can provide information regarding valence, coordination, bond- ing energy, and the composition of surface layers. We agree with Lieb- hafsky et al. (412) that the future of low energy X-rays lies in the interpreta- tion of spectra rather than the deter- mination of concentration. Low-energy X-ray and electron emission techniques are emphasized in this review. Energy dispersion techniques using radioactive isotopes as the source of excitation have grown rapidly during the past two years. This growth is due, in large part, to improvements in detector technology and to the com- mercial availability of a wide selection of isotopic sources. The lithium-drifted semiconductor detector with its high resolution capability opens new avenues of X-ray analysis. Energy dispersion and the semiconductor detector are extensively covered in this review. In electron probe microanalysis, there has been significant progress in defining and evaluating the parameters that are used to relate measured X-ray intensi- ties to composition. The evaluation of these parameters and their effect on the calculated concentration have been greatly accelerated by the use of com- puters. Heinrich outlined a plan for cooperative action on the determination of X-ray mass absorption coefficients (300). Better knowledge of mass ab- sorption coefficients is necessary for theoretically reliable methods for com- puting concentration. Cooperative ef- forts in determination of the various parameters, such as mass absorption and fluorescent yield, are to our mutual ad- vantage. Your support is requested in these efforts. The critical tabulation of K, L, RI, N, and 0 spectral lines by Bearden was recently published in Review of JIod- ern Physics (47). This tabulation was available previously as an AEC report. Atomic energy levels were compiled by Bearden and Burr (48). In their cal- culations, the wavelengths of all avail- able emission lines of an element were used to form an overdetermined set of equations that were solved by least squares to give a best set of relative energy levels. These values were then placed on an absolute scale by X-ray photoelectron measurements or by us- ing wavelengths of the absorption edges. X-ray wavelength and absorption edge tabies were computed by Dewey for use in electron probe microanalyzer cal- culations (183). Brockman and Whit- tem (90) compiled a condensed 28 table for first order spectral lines. As stated in our 1966 review, there are excellent wavelength and 28 tables already avail- able. We recommend the use of Beard- en’s tables (47, 48) for any additional 28 tables. Recent textbooks and conference pro- ceedings are listed in Table I. “Ad- vances in X-Ray Analysis” (430, 474) provides excellent summaries of recent developments in X-ray emission and electron probe microanalysis. There are three new textbooks on X-ray emis- sion techniques (5, 354, 468) and two books on electron microprobe analysis (496, 631). Hopefully some publisher will make Muller’s book available in English (468). There is occasionally a duplication of effort in the translation of textbooks. The book by Ulokhin (73), recently made available in Eng- lish by Pergamon Press, was translated into English in 1962 by the Hindustan Publishing Company (117). The “Handbook of X-Rays” was approxi- mately five years in preparation. This comprehensive book covers all aspects of X-ray analysis, including X-ray emis- sion and microanalyzer instrumentation and techniques (358). Because of the desire to achieve more rapid and detailed communications re- garding their research, the Spectro- chemical Section of the Kational Bureau of Standards is preparing detailed sum- maries of yearly progress (563, 664). These reports summarize facilities, pub- lications, personnel, and more im- portant, research in progress. Reports of this type from all of the major lab- oratories engaged in X-ray research would aid in reducing duplication of effort. Continuing education is becoming a way of life for most scientists, including those whose interest lies in X-ray meth- ods of analysis. Excellent introductory courses are provided by several of the instrument manufacturers at their plants or at various locations throughout the United States. Summer workshops at various universities provide an ex- cellent introduction to X-ray emission and electron probe microanalysis. Tech- nical societies are offering short inten- sive courbes as part of professional de- velopment programs. For example, the Washington-Baltimore Section of the Society of Applied Spectroscopy is presenting a series of five 2-hour lectures on X-ray emission techniques. RIore emphasis on radiation safety is strongly recommended, particularly as there will be a significant increase in the use of isotopes for energy dispersion analysis and in applications involving X-rays in the 50- to 100-key range. INSTRUMENTATION General. The manufacturers have continued the trend toward com- pletely automated and programmed X-ray spectrometers. Instruments are now available that can detect all elements from fluorine up through the periodic table. The program ill automatically select the 28 angle, analyzing crystal, Soller slit, detector, and pulse height analyzer setting, and then print out both the counts collected and the concentration. Obviously the accuracy of the analysis is no better than the match between standard and un- 346 R ANALYTICAL CHEMISTRY

X-ray absorption and emission

Embed Size (px)

Citation preview

Page 1: X-ray absorption and emission

X-Ray Absorption and Emission William I . Campbell, U. S. Department o f the Interior, Bureau of Mines, College Park Metallurgy Research Center, College Park, Md.

lames D. Brown, University o f Western Ontario, Faculty of Engineering Science, london, Ontario, Canada

s IK OUR 1964 (116) and 1966 (117) A reviews, we continue to use the format established by our predecessors Liebhafsky, Winslow, and Pfeiffer (413). This 1968 review consists of a critical evaluation of new developments and tabular summaries of X-ray spectrog- raphy and electron probe microanalysis. Stoddart and Dowden (614) recently compiled a comprehensive bibliography on fluorescent X-ray spectrography. Their bibliography is indexed by the element determined, matrix analyzed, author, equipment, method, and theory.

At present the principal application of X-ray emission and absorption tech- niques is to determine the concentration of specific elements. In the future X-ray emission techniques will find ad- ditional applications as analytical chem- istry becomes more sophisticated in characterizing materials. The Com- mittee on Characterization of Materials, Materials Advisory Board, National Research Council developed the follow- ing definition (441) : “Characteriza- tion describes those features of the com- position and structure (including de- fects) of a material that are significant for a particular preparation, study of properties, or use, and suffice for re- production of the material.” Low- energy X-ray spectroscopy supple- mented by photoelectron and Auger spectroscopy can provide information regarding valence, coordination, bond- ing energy, and the composition of surface layers. We agree with Lieb- hafsky et al. (412) that the future of low energy X-rays lies in the interpreta- tion of spectra rather than the deter- mination of concentration. Low-energy X-ray and electron emission techniques are emphasized in this review.

Energy dispersion techniques using radioactive isotopes as the source of excitation have grown rapidly during the past two years. This growth is due, in large part, to improvements in detector technology and to the com- mercial availability of a wide selection of isotopic sources. The lithium-drifted semiconductor detector with its high resolution capability opens new avenues of X-ray analysis. Energy dispersion and the semiconductor detector are extensively covered in this review.

I n electron probe microanalysis, there has been significant progress in defining and evaluating the parameters that are used to relate measured X-ray intensi-

ties to composition. The evaluation of these parameters and their effect on the calculated concentration have been greatly accelerated by the use of com- puters. Heinrich outlined a plan for cooperative action on the determination of X-ray mass absorption coefficients (300). Better knowledge of mass ab- sorption coefficients is necessary for theoretically reliable methods for com- puting concentration. Cooperative ef- forts in determination of the various parameters, such as mass absorption and fluorescent yield, are to our mutual ad- vantage. Your support is requested in these efforts.

The critical tabulation of K, L, RI, N, and 0 spectral lines by Bearden was recently published in Review of JIod- ern Physics (47). This tabulation was available previously as an AEC report. Atomic energy levels were compiled by Bearden and Burr (48). In their cal- culations, the wavelengths of all avail- able emission lines of an element were used to form a n overdetermined set of equations that were solved by least squares to give a best set of relative energy levels. These values were then placed on an absolute scale by X-ray photoelectron measurements or by us- ing wavelengths of the absorption edges.

X-ray wavelength and absorption edge tabies were computed by Dewey for use in electron probe microanalyzer cal- culations (183). Brockman and Whit- tem (90) compiled a condensed 28 table for first order spectral lines. As stated in our 1966 review, there are excellent wavelength and 28 tables already avail- able. We recommend the use of Beard- en’s tables (47, 48) for any additional 28 tables.

Recent textbooks and conference pro- ceedings are listed in Table I. “Ad- vances in X-Ray Analysis” (430, 474) provides excellent summaries of recent developments in X-ray emission and electron probe microanalysis. There are three new textbooks on X-ray emis- sion techniques (5, 354, 468) and two books on electron microprobe analysis (496, 631). Hopefully some publisher will make Muller’s book available in English (468). There is occasionally a duplication of effort in the translation of textbooks. The book by Ulokhin (73), recently made available in Eng- lish by Pergamon Press, was translated into English in 1962 by the Hindustan Publishing Company (117). The

“Handbook of X-Rays” was approxi- mately five years in preparation. This comprehensive book covers all aspects of X-ray analysis, including X-ray emis- sion and microanalyzer instrumentation and techniques (358).

Because of the desire to achieve more rapid and detailed communications re- garding their research, the Spectro- chemical Section of the Kational Bureau of Standards is preparing detailed sum- maries of yearly progress (563, 664). These reports summarize facilities, pub- lications, personnel, and more im- portant, research in progress. Reports of this type from all of the major lab- oratories engaged in X-ray research would aid in reducing duplication of effort.

Continuing education is becoming a way of life for most scientists, including those whose interest lies in X-ray meth- ods of analysis. Excellent introductory courses are provided by several of the instrument manufacturers a t their plants or a t various locations throughout the United States. Summer workshops at various universities provide an ex- cellent introduction to X-ray emission and electron probe microanalysis. Tech- nical societies are offering short inten- sive courbes as part of professional de- velopment programs. For example, the Washington-Baltimore Section of the Society of Applied Spectroscopy is presenting a series of five 2-hour lectures on X-ray emission techniques. RIore emphasis on radiation safety is strongly recommended, particularly as there will be a significant increase in the use of isotopes for energy dispersion analysis and in applications involving X-rays in the 50- to 100-key range.

INSTRUMENTATION

General. The manufacturers have continued the trend toward com- pletely automated and programmed X-ray spectrometers. Instruments are now available t h a t can detect all elements from fluorine up through the periodic table. The program ill automatically select the 28 angle, analyzing crystal, Soller slit, detector, and pulse height analyzer setting, and then print out both the counts collected and the concentration. Obviously the accuracy of the analysis is no better than the match between standard and un-

346 R ANALYTICAL CHEMISTRY

Page 2: X-ray absorption and emission

known, or the reliability of the mathe- matical correction procedures used.

During the past two years more at- tention has been given to two possible souices of instrumental error. The crystal chamber must be kept constant to k0.5OC to avoid systematic errors resulting from small shifts in peak posi- tion due to changes in d-spacing of the crystal. This problem becomes more serious when using high resolution optics with aut omat ed spectrometers. Also, the temperature and pressure of the counting gas in flow proportional counters must be stabilized because the gas amplification factor is affected by both of these variables.

Because of the difficulty and cost of obtaining an adequate supply of helium, the vacuum spectrometer is widely used outside the United States. This vacuum system results in slightly higher intendies owing to increased X-ray transmission of lowenergy X- rays; however, liquid samples are awk- ward t o analyze in a vacuum spectro- graph. Squirrel1 (608) modified a P W 1540 spectrometer to use either a partial vacuum-helium atmosphere or helium only. Excellent results were obtained with volatile organic liquids using the helium path.

Campbell and Hammond (1 14) auto- mated a commercial X-ray spectro- graph for continuous operation. The objective was to obtain the lowest pos- sible limit of detection and to optimize analytical precision by taking 100 to 200 measurements over extended count- ing periods.

A unique spectrograph was described by Zeitz (698) which uses a very thin transmission-scatter biological sample enclosed in a vacuum chamber. The amount of the element present is de- termined by intensity measurements us- ing a curved-crystal spectrometer. The characteristic X-rays are transmitted through the sample to a slit on the focus- ing circle. The sample weight is ob- tained from scattered X-rays using a propo~tional counter readout.

The Henke X-ray tube has been adapted to fit on a commercially avail- able vacuum spectrometer (257). Sam- ples are e x i t e d by low-energy X-rays, thus avoiding the problems of decom- position that occur when unstable com- pounds are subjected to electron bom- bardment. Although the grating spec- trograph of Holliday (328) offers supe- rior resolving power, the flat crystal spectrometer using an oriented soap film for dispersion is adequate for most applications (3f3). Probably the most versatile spectrograph for the low- energy X-ray region is the instrument designed by Mattson and Ehlert (55, 449). By changing voltage on either the cathode or anode, samples can be excited by electrons or X-rays. I n an- other configuration wires suspended

Author Adler, I. Blokhin, M. A. Brown, J. G. Castaing, R.,

Elion, H. A.

Descamps, J., Philibert, J., Eds.

Newkirk, J. B.,

Theisen, R. Mallett', G. R., Eds.

h e r . SOC. Testing Materials

Baker, P. S., Gerrard, N., Eds.

International Atomic Energy Agency

Parrish, W., Ed. Siegbahn, K.

Table I. Summary of Recent Books Title

X-Ray Emission Spectrography in Geology Methods of X-Ray Spectroscopic Research X-Rays and Their Applications X-Ray Optics and X-Ray Microanalysis

Instrument and Chemical Analysis Aspects of Electron Microanalysis and Macro- analysis

Practical X-Ray Spectrometry

Handbook of X-Rays Elektronenstrahl-Mikroanalyse Advances in X-Ray Analysis, Vol. 9

Spektrochemische Analysen mit

Advances in X-Ray Analysis, Vol. 10

Quantitative Electron Microprobe Analysis

Fifty Years of Progress in Metallographic Techniques

Second Symposium on Low Energy X- and Gamma Sources and Applications

Radioisotope Instruments in Industry and Geophysics-Vol. 1

X-Ray and Electron Methods of Analysis Alpha, Beta, and Gamma Ray Spectros-

COPY

Rontgenfluoreszenz

Sections on X-Rays

across two insulators are excited by electrons. The temperature of the wire can be varied by ohmic heating to remove any surface contamination. Gases can be introduced into the cham- ber containing the wire to investigate gas-solid reactions at selected tempera- tures. It is also possible to ionize gases at low pressures by electron excitation. The sample chamber and X-ray optical system are designed so that X-ray photons emitted by the chamber ma- terial do not enter the X-ray spec- trometer optics. Their instrument has been used for surveying a wide variety of materials (2O4,443). Campbell et al. constructed a soft X-ray spectrometer for the study of valence bands of metals (112). Their instrument uses a blazed concave replica grating at grazing incidence, with a photomultiplier as the detector. A moderately low-energy X- ray spectrometer was employed t o measure X-ray emission from the deu- terium plasma of a theta pinch reaction (395) *

Direct electron excitation X-ray spec- trometers are commercially available. The Telesec instrument can be preset for any combination of six elements (37) . The manufacturers state that in the past there were three major objec- tions to electron excitation-need for high vacuum around the electron gun, instability of system, and high back- ground. According to Telesec, these objections have been eliminated in their instrument. Japan Electron Optics Laboratory (379) also developed a primary X-ray analyzer. The electron

beam diameter is approximately 5 millimeters; the incident electron power is 0.5 to 5 watts in normal operation. Specimen holders are insulated from ground by a Teflon bushing enabling the absorbed electrons to be measured by a micro-microampere meter. Signal- to-noise ratios of 1700 to 1 and 1100 t o 1 were obtained for silicon Ka and aluminum Ka, respectively, using pure element standards. Further informa- tion on electron excitation can be ob- tained from publications on electron probe microanalysis ($3).

Excitation. There has been in- creased activity in the development of more efficient excitation on both t h e low- and high-energy X-ray regions. The stability of a commercially avail- able X-ray generator was critically evaluated by Ashby and Proctor (28). Over a 23.5-hour test with line voltage fluctuations of *15% the X-ray tube current and voltage were constant to 10 .02 and +0.05%, respectively. Dur- ing these evaluations Ashby and Proctor observed drifts in X-ray intensity which could not be explained by electronic in- stability. These drifts in intensity were found to be a result of changes in the X-ray transmission of the air path between the sample and the detector. The density of the air was changing with variations in temperature and pressure, Because of the high electronic stability, this small temperature-pressure effect could be observed. Yee and Deslattes (691) found that a transistorized current stabilizer for X-ray tubes using directly heated cathodes was operational over

VOL. 40, NO. 5, APRIL 1968 347 R

Page 3: X-ray absorption and emission

the 20- to 1000-mA range. The X-ray tube current was constant to =kO.l% for periods of a t least one-half hour. Linear polarization of X-rays was in- vestigated by Huffman (558). The linear polarization of X-rays produced in a mercury vapor target tube was analyzed by measuring the scattered intensity from beryllium parallel and perpendicular to the emission plane. Because fluorescent X-rays are isotropic, line-to-background ratios can be opti- mized by viewing the sample so that scattering of primary X-rays is mini- mized.

Machlett Laboratories (382) an- nounced the development of an ex- perimental thin-window platinum target X-ray tube. K i t h a 0.005-inch-thick beryllium window, this tube has charac- teristics equivalent to the conventional tungsten tube and the thin window chromium target tube. The dissipation of heat arising from backscattered elec- trons limits the size of their window to 0.5-inch diameter. Soviet scientists (594) designed a rhenium target X-ray tube that could operate up to a load of 3.5 kilowatts. The distance from the focal spot to the beryllium mindow is approximately 11 millimeters-about one half the distance of the Machlett OEG 60 tube. Operating at maximum power the beryllium window reached a temperature of 350°C. Electrostatic deflection of the backscattered electrons reduced the window temperature to 12O-15O0C. Taylor designed a high- intensity rotating-anode X-ray tube that could be operated at 250-275 milli- amperes at 30 kilovolts or 150 milli- amperes a t 50 kilovolts (625). The focal spot is 10 by 1 millimeters, and the ro- tational speed is 1750 revolutions per minute. H e anticipated construction of a 25-kilowatt X-ray tube for spec- trographic analysis.

Kathren (362) utilized a 200-kilovolt industrial X-ray unit to generate “monochromatic” X-rays. The “mono- chromatic” X-rays were generated by bombarding secondary sources Ivith a high-energy primary beam. A 150- kilovolt industrial unit was used to ex- cite uranium K lines for detection of uranium contamination (561). With the significant improvements in detector technology, we anticipate many new ap- plications of 50- to 100-keV X-rays.

Small X-ray tubes (30-mm diameter) were evaluated for drill hole logging of minerals. These tubes could be op- erated up to 100 kilovolts, giving a n X-ray output of 1Olo to lo1’ photons per second ( 2 ) . Gas-filled tubes operated intermittently and their output was only one half to one fourth that of a heated-filament X-ray tube. Minia- turized X-ray tubes were evaluated for excitation of low atomic number ele- ments on the lunar surface (172, 198, 464).

The Cristallobloc 31 X-ray tube has a cylindrical rotatable anode with six faces for fluorescent excitation (635). When the primary excitation mode is used, the sample is placed in slits ma- chined in the copper block. The Ray- max demountable tube (580) was used to evaluate excitation parameters in the lowenergy X-ray region. Maximum intensity was obtained with high take- off angle, low angle of incidence of the electron beam, and optimum voltage setting. Losev et al. (417) made similar studies on the escitation of silicon K radiation. In addition they evaluated the output from 10 anodes ranging from beryllium to gold. Walker (659) used a commercially available demountable X-ray tube in a windowless configura- tion. Results were compared with those obtained with 30- and 100-micron beryllium windows. When the window was absent deflection plates were used to eliminate scattered electrons. One rela- tively simple way to increase intensity of the low-energy X-rays is to eliminate the plastic film holding the sample. Beard and Proctor (45) designed a windowless solution holder that gave a reproducible height of solution. The uncovered holders gave a 3- and 6-fold increase for sulfur and aluminum K a , respectively, compared with holders with 1/4-mil mylar windows.

Davidson and Wyckoff (176) re- examined the cold cathode gas tube for use in the low-energy X-ray region. Contamination of the target was not a problem, in contrast to the buildup of impurities using the heated cathode. Their air-cooled tube could be operated up to 200 watts.

A demountable X-ray tube was op- erated at 10 to 20 kilovolts and 200 to 300 milliamperes (182). The power on the tube is limited by the rate of dissipa- tion of heat; this power can be in- creased by using pressurized coolant.

Dispersion. Activity reported on the development of improved analyz- ing crystals has decreased during the past two years. Resolution and in- tensity of spectral lines are directly related t o the analyzing crystal; therefore a greater research effort is warranted.

Isomet Corporation recently an- nounced the commercial availability of OHM (octadecyl hydrogen maleate) crystals for use in the long wavelength region. These crystals offer high r,e- flectivity and a 2d spacing of 63.5 4. Sparks (598) found that oriented hot- eressed pyrolytic graphite, 2d = 6.70 A, has excellent potential as an X-ray monochromator. The diffraction effi- ciency of the 002 reflection for copper K a is approximately 50% if the diver- gence of the X-ray beam does not exceed the mosaic spread of the graphite. The peak width is full-width half-max- imum. Sparks found that graphite

gives a 5-fold increase in intensity as compared to lithium fluoride.

Crystals and oriented soap films used for X-ray analyzers are summarized in Tables I1 and I11 taken from a paper by Baun and Fischer (41). Of the newer crystals, clinochlore (a naturally occur- ring cLystal) looks promising for the 10 to 20 A region. As there appears to be a useful upper limit to the d-spacing of soap films, Baun and Fischer suggest alternate deposition of a thin film of a strong scatterer and a precisely con- trolled sandwich layer of a low scatterer. Although their approach is restricted by the present ar t of vacuum deposition, the suggestion merits further study.

Chan (142, 143) found that certain PET crystals grown in his laboratory gave 2.5 times the reflectivity of E D d T and 9 times that of mica for silicon K a radiation. For a pure silicon sam- ple, count rates in escess of 106 counts per second were achieved. Chan cau- tions that PET crystals should be kept in a desiccator when not in use.

Advantages of soap films and gratings are compared by Henke (309). Previ- ously, lowenergy X-ray spectroscopy was accomplished by diffraction grat- ings a t grazing incidence. Xew tech- niques for making low-angle blaze grat- ings have greatly improved intensities. More recently most of the research in lowenergy X-ray spectroscopy has been accomplished using Langmuir-Blodgett type of analyzers. Using the oriented soap films at a high B r a g angle, a significantly larger total solid angle of radiation is viewed as compared to the small angle grazing incidence geometry. Excellent discussions on the preparation and properties of soap films were pre- sented by Ehlert and 3lattson (203, 205). Optimization of slit width for focusing spectrometers is discussed by Lavrent’ev and Vainshtein (405).

Detectors. During the past two years there has been significant research on the pulse amplitude shift as a func- tion of X-ray intensity (227). Burk- halter, Brown, and Nyklebust (104) compared a variety of sealed and flow- proportional counters for peak shift as a function of counting rate. The two significant findings were that peak shifts were larger for flom-proportional counters than for sealed detectors and that the peak shift was a strong func- tion of anode voltage. For esamole, a t 1500 volts the peak shift is 57, coin- pared with a 50% shift a t 1900 volts. I n contrast a sealed detector operated at 1750 volts gave no observable shift from 500 to 50,000 counts per second.

Sanford and Cclhane (654) found that performance at high count rate could be improved by using a n inert gas of low atomic number, by increasing the de- tector capacitance (increasing the anode wire diameter), and by operating at a low gas multiplication factor. Spiel-

348 R * ANALYTICAL CHEMISTRY

Page 4: X-ray absorption and emission

beig (601) concluded that the density ot the po,itivc 1011 space charge depends on the aiiode ni le diameter, as most of thc charge multiplication in the detector takes place close to the anode wire. Therefole the peak shift should be re- duced by incieasing the wire diameter. Veiy little shift was observed using a 0.012-cni-diameter wire. Higher op- e1 atiiig voltage \\as required, but did not create any special problems. The type of anode material (602) was also found to have an effect on pulse shift. A detector using an anode wire of 50-,u- diameter tungsten had a significantly loner shift thaii the same detector with a 50-p-diameter stainless steel wire. d gas pressuie control system for the flow counter was described by Spielberg (600). He concluded that, in an air- conditioned room, additional tempera- ture control on the flow counter gas was not required.

Practical techniques for casting thin formvar films on water nere described by LIeriitt and Agazzi (.@2), A rug- gedized thin window counter was de- signed for space applications (559). The variation of gain and resolution with time for a sealed thin window counter was investigated by Culhane et al. (166). The deterioration in gain and resolution mas restored by either placing the counter in a desiccator with phosphorus pentoside or by bubjecting the counter to dry ice temperature. dpparently the counter deterioration resulted from water vapor leaking through the windo\\. .ipplications of gas-flow and sealed proportional counters ale described in the following papers (111 , 113, 15'9, 467, 654). An excellent source of information on scin- tillation counters is the recently revised book by I3irks (64).

There have been major improvemeiits in the lithium-drifted silicon and ger- manium detectors during the past two years These detectors offer escellent resolution in the medium- and high- energy X-ray region. Excellent re- view paperq on the state of the ar t have been published recently (177, 270, 325- 327). If the reader is not familiar with the new detectors, the introductory papers by 13oanian et al. (83) aiid Heath (2Y6) are recommended.

The active counting volume of a lithium-drifted detector is formed by drifting lithium into a p-type silicon or gernianiuni crystal under carefully con- trolled conditions (260). The function of the lithium i, to compensate for the effect of impurities The detector is coniprised of a region of compensated silicon or germanium sandwiched be- tneeii a very thin 1,-type and n-type region. 13y applying a bias voltage to the detector in the reverse direction, the detector becomes a high-impedance device. This electric field depletes the compensated region of free charge car-

Name Topaz Lithium fluoride Sodium chloride Calcite Silicon

Fluorite Germanium

Potassium bromide Ammonium phosphate Pentaerythritol Ammonium tartrate Ethylene diamine d-tartrate Ammonium phosphate Ammonium tartrate Ammonium citrate Sucrose Gypsum Beryl Itaconic acid

Table I I . Analyzing Crystals (47 )

Mica Potassium acid phthalate Clinochlore Bismuth titanate Octadecyl hydrogen maleate Octadecyl hydrogen succinate

2d, A 2.71 4.02 5.64 6.06 6.28

6.30 6.53

6.58 7.50 8.74 8.80 8.80

10.64 14.15 14.92 15.12 15.18 15.96 18.50 19.91 26.63 28.42 32.84

Notes Natural mineral Durable, strong reflection Cleavage, easily bent Durable natural mineral, cleavage Semiconductor slices may be used, suppressed

Cleavage Semiconductor slices may be used, suppressed

N o cleavage, easily bent Large natural growth face Soft, difficult to grow, intense reflections Cleavage, easy to grow from HzO solution No cleavage Easy to grow from H20 solution Large natural growth face Natural growth face Difficult to grow, spontaneous nucleation Dehydrates in high vacuum, easily bent Natural mineral Cleavage Natural mineral, cleavage, easily bent Growth from H20 solution, cleavage Natural mineral, cleavage, easily bent Platelets, may be bent Both difficult to grow, long growth cycles,

second order

second order

spontaneous nucleation

Name Lead laurate Lead myristate Lead palmitate Lead stearate Lead arachidate Lead lignocerate Lead mellissate

Table 111. Soap Film-Multilayer Analyzers (47 ) Number

of carbon atoms 2d Spacing, -1 Notes

12 70 Possible degradation in vacuum 14 80.5 16 90 Easy to prepare 18 100.79 Easy to prepare 20 110 Easy to prepare 24 131.45 More difficult to prepare 30 165 More difficult to prepare and

usually poor quality

riers (electrons and holes). This de- pleted region is the radiation-sensitive volume of the detector. Typical de- tector areas and depths are 30 to 100 square millimeters and 2 to 5 milli- meters, respectively.

A large number of ion pairs are formed per incident photon, but these semicon- ductor detectors do not have the high multiplication typical of the pulse formed in the gas proportional type counter. Therefore, a very low-noise, high-gain preamplification is required (207, 208). This preamplification is achieved by operating a field effect transistor a t liquid nitrogen temperature (661). The detection efficiency is the function of the depletion depth and the atomic number of the semiconductor. A 3-millimeter-thick silicon diode will absorb approximately 50% of 30-keV X-ray photons; however the photo- electric absorption of silicon decreases rapidly with increasing X-ray energy. For higher energy X-rays, germanium is the detector of choice because of its higher photoelectric absorption co- efficient.

The principal advantage of the lithium-drifted detector is the signifi- cant improvement in resolving power as compared to proportional and scintil- lation counters. The theoretical width of the measured pulse is related to the statistical spread in the number of elec- tron-hole pairs formed by photoelectric absorption. Resolution is convention- ally expressed by the following relation- ship

FTVHM (keV) = 2 . 3 5 5 a (1) where E = energy of incident electron

or X-ray photon in keV e = average energy to create

electron-hole pair = 3.6 eV for silicon,

F = the Fano factor For small-diameter detectors, the Fano factors for germanium and silicon are 0.15 and 0.20, respectively (296). The observed line width also includes con- tributions from various sources of noise in the detector and in the electronics, Resolutions of 0.5 to 0.7 keV ( F W H M ) have been reported for silicon detectors in the 5- to 30-keV region. The ex-

VOL. 40, NO. 5, APRIL 1968 * 349 R

Page 5: X-ray absorption and emission

celIent resolution of the germanium de- tector for high-energy K X-rays is shown in Figure 1 (83). Of particular significance is the separation of the Kala2 doublets of thorium and uranium. By using amplifiers with pole zero cancellation, the problem of peak broadening at high count rate has been virtually eliminated. Pulse widths did not show any apparent broadening for count rates up to 15,000 counts per second (296). The lithium-drifted de- tectors have great potential for energy dispersion analysis. Information can be obtained in a few minutes regarding the overall sample composition using a lithium-drifted detector coupled with a multichannel analyzer. We predict these detectors will find extensive appli-

b Figure 1 . K X-ray spec- tra of high atomic number elements using a lithium-drifted ger- manium detector (83)

a z

w In

W

In I- z 3 0 V LL 0 m z In 3 0 I I-

:: a a

a a

- , Lr, , , ,

2 I K 8 2

60 70 80 90 100 110 120 X-RAY ENE'RGY.'keV

Table IV. Specific X-Ray Spectrographic Analysis Aluminum

In alloys and metals (146, 162, 227, 234, 236, 400, 466) In minerals and ores (199, 360,384, 663, 677) In miscellaneous materials ( I 78, 394, 526)

Antimony (400,457, 479,681) Arsenic (431 , 433, 457, 681 ) Barium (126, 372, 613) Beryllium (204) Bismuth (433) Boron (204, 230, 233) Bromine (542, 671, 608, 657) Calcium

In cement materials (178. 677) In minerals and ores (199, 384, 477, 653, 677) In miscellaneous materials (394, 516, 626, 642) In organics (12, 54, 1.61, 499)

Carbqn (230, 238, 370) Chlorine (12, 181, 384, 642, 668, 657) Chromium

In alloys and metals (77, 202, 280, 372, 411, 457) In miscellaneous materials (64)

Cobalt In metals and alloys (163, 411, 457, 697) In miscellaneous materials (464, 606, 630, 686) In organics (64)

Copper In alloys (32, 171, 306, 229, 380, /ill, 469) In metals (146, 372, 642, 697) In miscellaneous materials (184, 464)

Fluorine (56, 443) Germanium (681) Gold (89, 144, 171, 206) Hafnium (3, 240, 259) Iron

In alloys and metals (77, 1.45, 163, 234, 280, 372, 411, 466, 628,

In cement materials (178) In minerals and ores (184, 199, 384, 477, 653, 677) In miscellaneous materials (59, 376, 464, 616, 626, 642) In organics (54, 210, 263) In soils (360)

In alloys and metals (171, 432, 466, 697) In minerals and ores (666) In miscellaneous materials (433, 616, 630, 667) In organics (608)

In metals (372, 697) In minerals and ores (565) In miscellaneous materials (360, 394) In slags (178)

597)

Lead

Magnesium

Manganese (52, 77, 202, 372, 411, 466, 697, 677) Mercury (433)

Molybdenum In alloys (457) In miscellaneous materials (52, 184, 421, 668) I n steels (202)

Nickel In alloys and metals (145, 153, 236, 280, 372, 466, 697) In miscellaneous materials (52, 63, 59, 163, 199, 464, 626, 642,

658) Niobium

In alloys (400, 457) In miscellaneous materials (506. 685) ~, I

Nitrogen (230, 238) Oxvnen (LLc?)

Y a- ~ \ r r - I

Palladium (206) Phosphorus (12, 241, 400, 626, 677) Platinum (206) Potassium (12, 199, 384, 477, 499, 626) Rare earths

Rhenium (457) Rubidium (621) Selenium (431, 433, 681 ) Silicon

In metals (146, 381, 628) In miscellaneous mixtures (11, 616, 683)

In alloys (202, 372, 400, 636) In cement materials (178) In minerals and ores (161, 199, 384, 653, 677) In miscellaneous materials (142, 143, 360, 394, 626)

Silver (171, 206, 535) Sodium (59L 655) Strontium (740, 457, 621, 639, 682) Sulfur (12, 230, 262, 384, 451, 472, 658, 674, 608, 672, 673) Tantalum (457, 506) Technetium (421) Tellurium (103) Thallium (ASS. L57) Thorium (69, $0, 386, 683) Thulium (340) Tin (126, 139,400, 467, 465, 479, 630, 692, 681) Titanium

In metals (400, 411) In minerals and ores (384, 477, 563, 677) In miscellaneous materials (54, 506, 626, 683)

Tungsten (31 ) Uranium (69, 293, 372, 386, 683) Vanadium (53, 180, 400, 457) Yttrium (27, 586, 578, 683) Zinc

In metals (32, 77, 206, ?29, 372, 380, 434, 466, 697) In miscellaneous materials (69, 626, 666) In organics (263, $17, 698)

In metals (269, 400, 624) In minerals and ores (3) In miscellaneous materials (464, 630)

Zirconium

350 R ANALYTICAL CHEMISTRY

Page 6: X-ray absorption and emission

cations in several phases of X-ray emis- sion analysis.

Grodski (272) and Uaun and Fischer (39) recently summarized the state of the ar t for photoelectric-type detectors. There are four basic types of these de- tectors : multidynode, secondary electron multipliers; resistance strip magnetic multipliers; continuous channel multi- piers; and detectors in which photoelec- trons are accelerated and subsequently counted. The detectors differ in the method by which the photoelectric signal is collected and amplified. All of the detectors are windowless-the incident X-ray photons are the direct cause of the photoelectric emission from a cathode. The photocathode ma- terial has a very pronounced effect on the detector efficiency. These detectors have a poorer signal-to-noise ratio than proportional counters, but their fast pulse rise time permits very high count rates, Presently application of the photoelectric detector is limited to the very low energy X-ray region.

Characteristics of avalanche type semiconductor detectors are summarized by Huth and Locker (342). Possible advantages of the avalanche-type de- tectors are small size, ruggedness, and speed of response. At the present stage of development resolution is poorer than for the gas-filled proportional counters.

QUANTITATIVE ANALYSIS

Emission. X-ray spectrography continues t o be used for an increasing number of applications, both for re- search and for quality and process control (674). Methods for specific elements are listed in Table IV. Analy- sis of various classes of samples are sum- marized in Table V. In the comprehen- sive bibliography by Stoddart and Dow- den (614), there is an index listing the element determined and the matrix being analyzed. Another excellent source of methods is the Applications Review, pnblished by Analytical Chem- istry every two years. X-ray emission methods were compared to chemical (402) and optical (201) techniques with regard to accuracy, precision, range of application, difficulty, time, and cost.

Although there has not been any major development, there has been steady progress in quantitative aspects of X-ray analysis. These applications range from incinerator slags (626) to logging minerals in situ (45.5) and the analysis of the Moon’s surface (172, 637). Backerud (32) presented a crit- ical discussion of the determination of copper in complex brasses. The ratio of copper Kpl to zinc K a was used to eliminate dependence on surface prep- aration, sample size, and samp1e-to-X- ray tube distance.

Applications of various techniques were described in the following papers-

addition (425), dilution (167, 584), emission-transmission (41 0) , external standard (507), fusion (184, 287, 690), line to scatter (74), and solutions (655).

Smagunova et al. (585) compared the accuracy of seven standard methods for analyzing ores. Their studies included absorption correction, addition, dilu- tion, internal standard, and line-to- background. They concluded that the internal standard approach gave the most reliable values. Czamanske et al. (167) compared dilution techniques with simple briquetting for powdered samples. They reported that uncer- tainties associated with undiluted Sam- ples, moderate dilution, and moderate dilution-fusion methods, make these techniques less generally applicable than suggested in the literature. They conclude that the analyst must either account for absorption and enhancement effects or create an essentially identical matrix for sample and standard. For- mulas for the calculation of optimum amounts of diluent are covered by Duimakaev and Blokhin (193).

Champion and Whittem (141) com- pared solution analysis on a weight basis rather than the conventional volume basis. Their paper merits wide- spread consideration because their ap- proach reduces systematic errors. Ma- trix effects, the magnitude of which are related to the type and amount of acid or base added, are significantly reduced when samples are compared on a weight basis rather than by volume. A crit- ical investigation of their approach is recommended.

Applications of computer techniques to achieve quantitative results continue to increase in the production and control laboratories. The Lucas-Tooth com- puter program is the one that is widely used (206, 260, 390, 419, 553). Sander- son and Yeck list a program for use with a small computer (553). Their program is used for ferrotitanium ores and resi- dues of widely varying composition. Alley and Myers (13) used multiple regression to analyze ingredients in a rocket propellant mix. Another re- gression technique (324) was used to obtain estimates of mass absorption co- efficients as a function of wavelength. These coefficients were then employed in the calculation of concentration from measured X-ray intensities.

A semi-theoretical method was pro- posed by Andermann (16) for obtaining exponential correction factors for cal- culation of interelement effects. His method is based on ratios of the differ- ence in mass absorption coefficients be- tween unknown and standard. Ac- cording to Andermann, his method does not require a large library of standards and the direction of change from inter- element effects is easily predicted. Dis- advantages are that all elements pres- ent in the sample must be considered

Table V. Applications to a Specific Class of Samples

Alloys Copper base (32, 380, 466) Ferrous (419) General (280, 318, 634) High temperature (403) Light metals (77) Platinum group (206) Titanium (L67)

Aluminum (372) ’ hlqminum oxide (463) Archaeology (1 27, 171 ) Biology (12, 1.40, 141, 263, 692) Boron (107, 642) Carbides (409, 606, 668, 686) Catalysts (616) Cement (463) Clay (360) Clinical chemistry (28, 473) Coal (108, 384) Electronics (375) Flue dusts (666) Foods (499) Gases (181. 668) Geochemistry ( f l , 140, 288, 477) Glass (139, 394) Gold (693) Incinerator slags and fly ash (262, 626) Industrial hygiene (464, 667) Iron and steel (202. 400) , . . Iron ores (677)‘ Meteorites (690) Nickel (411) Ores (11, 169, 184, 287, 634, 663) Organics (64, 143) Paints (647) Petroleum (63, 210, 674) Plastics (608) Protective coatings (163, 186) Radioactive materials (293, 361, 464,

Rare earths (628,678) Rocket propellants (13, 469) Silicates (161, 390, 394) Slags (162, 178, 677) Soils (646)

683)

and enhancement effects are not cor- rected.

The use of scattered X-rays for ma- trix correction should expand rapidly, particularly in conjunction with energy dispersion techniques. Hahn-Wein- heimer et al. (278) investigated the re- lationship of scatter to mass absorption coefficients of the sample. Myers et al. developed a mathematical procedure for correcting for particle size and ma- trix based on scattered X-rays (469). They analyzed mixtures of potassium perchlorate, titanium, aluminum, and a binder. Matrix effects can be corrected by the use of Compton scatter measure- ments (420). The Compton scatter intensity is dependent on matrix com- position in the same manner as fluores- cent X-rays. This approach to matrix correction warrants further considera- tion.

Most mathematical procedures for calculating concentration from meas- ured intensities use an “effective wave- length.” Grothe and Krause (274) found that 50% of the excitation of a cobalt-nickel sample was accounted for by the tungsten L radiation and 50% by the continuum. For a 50-50 nickel-

VOL 40, NO. 5, APRIL 1968 * 351 R

Page 7: X-ray absorption and emission

cobalt mixture, 8% of the cobalt radia- tion resulted from excitation by nickel Kp radiation generated in the sample (275). Obviously the use of a single “effective” wavelength gives incorrect results. Salem and Zarlingo (552) found that, with thick targets, indirect ionization contributes to line produc- tion; with very thin targets, line emis- sion results from direct collisions only. The spectral composition of the ex- citing radiation strongly affects the ac- curacy of analysis according to Pav- linskii (497). They compared results obtained from yttrium and strontium samples mixed with different filters using molybdenum (characteristic plus continuum) and tungsten (continuum only) radiation.

I\‘hen determining a high atomic number element in a low atomic num- ber matrix, the calibration curve is nonlinear because of the strong absorp- tion of the high atomic number element for its characteristic K or L radiation. One way to extend the linear portion of the calibration curve is to use a long- wavelength AI spectral line. In this wavelength region, low atomic number elements make a significant contribu- tion to the absorption coefficient of the sample (273).

Particle size and matrix effects are the principal parameters to be considered when preparing samples for X-ray spectrographic analysis. High-speed impact mills provide a 1- to 10-micron particle size range for low atomic num- ber elements (424). Materials must be physically homogeneous initialry, be- cause the milling is highly selective to hardness, cleavage, and fracture.

Based on our experience, the recom- mended method for minimizing par- ticle size and matrix effects is dilution plus fusion. Pyrosulfate fusion and its advantages are summarized by Diae and Anderson (184). Borax fusion con- tinues to be the most widely used tech- nique (287, 390, 401, 690). A minus 100-mesh low-melting, low-viscosity glass composition, composed of six parts boric oxide, two parts sodium carbonate, and one part lithium tetraborate, is available from Corning Glass. One of the principal problems with borax fusion has been the adherence of a portion of the sample to the crucible. This re- sults in a loss of sample plus a difficult, time-consuming cleaning step. Using a Palau crucible (800/, gold-20% pal- ladium), the borax fusion pours cleanly out of the crucible (590). Other prom- ising alloys are platinum %%-gold 5% and platinum 80%-gold 5%-rhodium 157, (private communication with Colin Van Zyl, Anglo American Research Laboratories).

Surface preparation is a critical step in the analysis of leaded copper alloys (432). The primary reason for in- accurate analysis is the presence of a

damaged surface layer that is depleted in lead. Metallographic polishing of the samples tends to minimize this problem. One of the reviewers (W.J.C.) is presently evaluating the use of lead K a radiation for analytical problems such as the leaded alloys. The use of high-energy K radiation, penetration of approximately ‘/8-’/4

inch, will minimize grain size and sur- face preparation variables.

Natelson (472) developed a sulfur densitometer for scanning paper elec- trophoretic strips to determine serum protein. Electrophoresis of the serum protein was accomplished using con- ventional paper tape. This tape was fed continuously into a vacuum X-ray spectrograph to monitor the sulfur in- tensity. Preparation of biological sam- ples is described by Zeitz (692) and Anspaugh et al. (22). Determination of halogens and sulfur in gaseous samples was accomplished by Schnell (568). The chromatographic effluent (carrier gas plus constituents being determined) is passed through a capillary that is irradiated by an intense X-ray beam. The elements present in the effluent are determined by measuring the secondary X-rays leaving the capillary. With a 50-mm capillary, the detection limit was 5 x 10-7 gram of carbon disulfide per milliliter of carrier gas.

Applications, advantages, and limita- tions of various plastic binders were con- sidered (650). One application is to convert lipophilic liquids plus an in- ternal standard into a solid sample. Karttunen (361) developed a technique for handling radioactive materials. The dissolved materials are placed in a glass cell and this cell is covered with a Mylar sack; then the Mylar is heat-sealed to prevent leakage. Sample preparation techniques for various types of samples are described in the following papers: nonmetallics (677), minute mineral specimens (288), slimes (418), and sedi- ments (161).

Process and Quality Control. The characteristics of X-ray emission methods-specific, rapid, and non- destructive-are ideally suited for process and quality control analysis. x’ow tha t isotopic sources and energy dispersion systems are becoming widely available, dynamic analysis should be greatly accelerated. The isotopic source eliminates the need for a n expensive and bulky power supply and X-ray tube; in addition, isotopes are stable sources of X-rays.

The principal difference between on- line and laboratory-type analysis is in the sample preparation and presenta- tion. Obviously, sample preparation must be held to a minimum for on-line analysis. Fusion or dilution techniques are not possible without seriously de- laying the time between sampling and analysis. The best approach for ma-

trix correction is to use backscattered or transmitted X-rays to obtain knowledge regarding the absorption characteristics of the sample.

The Elliott automatic double path spectrometer is used for quality control of brass and bronze production (580). Samples are either large solid pieces or briquetted drillings. Excellent results are obtained using the ratio of copper to zinc K intensity. Craig (162) presented a thorough discussion on application of X-ray emission methods to control anal- ysis of lead blast furnace slags. Ex- amples of quality control instrumenta- tion using both fixed and programmed spectrometers were described by David- son and coworkers (174) and Furbee (265).

Apparatus for sampling a number of continuously flowing streams of ma- terials was patented by Pick and Bing- ham (604). Samples can be in the form of powders, slurries, or solutions. Details of wet and dry methods of sam- ple preparation and presentation for dynamic analysis were summarized by Shequen and Smallbone (672). Olie way to handle slurries is to place the sample on a fast-moving belt; the approximate speed is 3 meters per second, and the thickness of the slurry layer is 1.5 to 2 nim (618). No X-ray window is required between the slurry and the X-ray tube. Another ap- proach to slurry presentation is to centrifuge out the solid material by a tangential injector. Then the solid material is passed in front of the X-ray tube. With this technique, the per cent of the element in the solid is independent of the solid content of the slurry (124). Smallbone used scattered radiation at 0.45 A to correct for pulp density and matrix (586).

Carr-Urion concluded that an on- stream analyzer using radioisotopic sources and energy dispersion analysis gave excellent results (122). Various techniques to correct for or to minimize particle size effects in slurry analysis were described by Carr-13rion el al. (121, 123, 125).

Trace Analysis. Fluorescent X-ray spectrography continues t o be used for an increasing number of applica- tions in the trace element range (8). Trace elements are determined in the original sample (Class 1) or as isolated microgram quantities chem- ically separated from the host material (Class 2). Recent publications on all- plications and techniques of trace ele- ment analysis are listed in Table VI. Natelson and Whitford (473) prepared a thorough review of clincial applications. They offer a number of practical sug- gestions regarding optimization of signal to noise, sample preparation techniques, and the use of primary X-ray filters. Probably the most extensive application of trace analysis is directed toward

352 R ANALYTICAL CHEMISTRY

Page 8: X-ray absorption and emission

biological problems. Anspaugh et al. (88) are attempting t o correlate trace element concentration and disease; for example, the relationship of diabetes to copper content in the serum and the age of the patient. Standardization of analysis for these biological fluids is accomplished by the addition method. These “standard” samples are sub- sequently lyophilized and pressed into wafers as are the unknowns. Zeitz (698) determined the zinc content in tissue sections. In his procedure the zinc KCZ radiation is transmitted through thin specimens. Sample weight is de- termined by scattered radiation meas- ured nondispersively. Very high sen- sitivity is achieved using his transmis- sion sample-curved crystal focusing geometry.

Direct electron excitation of trace elements was evaluated by Toussaint and Vos (635). Detection limits were 0.7 and 11 ppm for silicon and magne- sium in aluminum, respectively. The relative sensitivity of direct electron excitation] as compared to secondary X-ray excitation, is still debatable (65). However, in our opinion, X-ray excita- tion with its greater signal-to-noise ratio is equal or superior in sensitivity to electron excitation.

Applications to Class 2 samples are limited only by the complexity of the analytical chemistry required to con- centrate and isolate the elements of interest. For example, low concentra- tions of hafnium dioxide in zirconium dioxide are determined by melting the oxide with sodium thiosulfate] dissolv- ing the melt in aqueous ammonium thiocyanide, and concentrating the hafnium oxide by a three-stage liquid- liquid extraction process (240). Trace toxic elements in water are determined by chelating the elements with the ammonium salt of pyrrolidine dithio- carbamate, extracting into chloroform, and evaporating the chloroform extract on filter paper (433).

Based on our experience, the ion- exchange resin-loaded papers offer the best general approach to Class 2 sam- ples. Principles, general instructions, and applications are described in two publications by the Bureau of Mines (118, 597). By using smaller ion- exchange resin paper disks, other re- searchers achieved sensitivity €or frac- tional microgram quantities of nickel and vanadium in petroleum products and terephthalic acid (63, 54).

Absorption. There were no major developments in quantitative analy- sis based on absorption techniques during the past two years. Radio- active isotopes such as beta (165, 514) and gamma (508) emitters provide a stable, inexpensive source of X-rays. Pruess et al. (514) suggest applications for beta sources using copper, iron, and molybdenum targets. Their compila-

tion of beta-excited X-ray spectra (615‘) is an excellent contribution to the litera- ture. Spectra are presented for cal- cium-45, phosphorus-32, and promethi- um-147 in various source configurations.

A three-wavelength X-ray absorption edge method was developed for the de- termination of plutonium in a nitrate medium (279). Two of the wave- lengths bracket the plutonium LIlr edge; the third wavelength is used to mini- mize the systematic error in determin- ing the value of a constant used in the calculation of concentration. The rela- tive standard deviation was +0.6% for concentrations of 10 to 25 mg per ml. Absorption techniques M ere employed to determine composition of rhodium- beryllium alloys (360) and metals in hydrocarbons (165). North (482) adapted an older model Philips fluores- cent X-ray spectrograph for absorption analysis.

Thin Films and Coatings. Com- position and thickness of thin films and coatings can be determined by either X-ray emission or absorption techniques. For ultra-thin films, sev- eral monolayers or less, newer tech- niques described in subsequent sec- tions of this review are applicable; however, proton excitation, photo- electron spectroscopy, and Auger spectroscopy are not so well developed as the conventional X-ray methods.

Ebel, Jax, and Perez (200) developed an absolute method for film thickness measurements in the 50 to 5000 .k range. They measured X-ray intensi- ties a t two or more takeoff angles and used these data to calculate thickness; no standards were required. Cline and Schwartz (152) determined the thickness of aluminum on silicon in the range of 0 to 4 microns. Two methods were compared-aluminum K emission, and absorption of silicon K a . The alumi- num K emission method was concluded to give the best results; the sensitivity was =t6 A of aluminum. Various meth- ods for determining thickness of tin plate were compared (692). The two methods giving the beat results were measurement of characteristic X-rays from the coating layer (tin) and of characteristic X-rays for the base ma- terial (iron). The latter measurement is preferred for on-line control because of its higher intensity output and lower background. Sickel-chromium films are of importance for their magnetic properties. Values obtained by X-ray emission and absorption methods are in excellent agreement with those ob- tained by colorimetric and interfero- metric methods (604). Films of noble metals were determined using a moly- bdenum X-ray tube. The calculation of thickness was based on the assump- tion that the exciting wavelength was independent of film thickness (186). Thin films, 600 to 1300 A, of nickel,

Table VI. Trace Analysis-Samples and Techniques

Samples (Class 1) Biological and clinical (22, 140, 263, 472,

Inorganic solutions (381, 421, 433, 464, Metals 613,682) (59, 98, 103, 293, 400, 697, 694)

Minerals (11, 140, 288) Nonmetals (107. 120. 134)

475,692)

. . Organics (63, 64, 421) Oxides (69, 240) Thin films (472)

Techni ues (Class 2) Ashe\ residues (263, 667) Evaporated residues (22, 433, 516) Impregnated papers (64, 472) Ion-exchange papers and membranes

(62, 63, 98, 118, 139, 293, 385, 464,

llicropore filters (103) Precipitation (624, 681 )

697)

cobalt, and iron were determined by stripping the films and analyzing the resultant solutions (153). This ap- proach can be used for any film that can readily be dissolved.

The use of backscattered beta rays, backscattered X-rays, and fluorescent X-rays was discussed in two excellent papers on the use of radioisotopes (110, 529). Rhodes (529) covers prin- ciples and applications and lists charac- teristics of various isotopic sources. Margolinas (484) evaluated a radio- isotopic gauge for determining zinc coating produced in a galvanizing proc- ess. A 100-mCi Xm241 source was used with a proportional counter readout. The accuracy of the measurements is =tl micron over the range 50 to 210 g/m2 and =t2 microns over the range 160 to 350 g/mZ. Margolinas estimates that a gauge costing 40 to 60 thousand dollars can be paid for in 10 months by the improvement in process control.

X-Ray Probes. X-ray macroprobes are a n excellent supplement to the electron probe microanalyzer. Kon- conductors can be analyzed, and sur- face preparation is not so critical for X-ray excitation as for electron probe measurements. Most of the X-ray probes are a t tachments to commercial X-ray spectrographs. Reduction in spot size is accomplished by collimation of either the primary or secondary X-ray beam. Bertin compared four slit sys- tems for selected area analysis (60). H e concluded that the inclined slit is preferred because this slit combines high sensitivity, excellent resolution, and narrow spectral lines. .Li modified Siemens Crystalloflex IV was used to study segregation of chromium in steel (355). .1 wide range of applications of the X-ray probe was described by Loomis and Storks (416). One of their problems was to determine the source of lead in cow stomachs. A unique focus- ing spectrometer X-ray probe was de- signed by Garton, Campbell, and Wat- ling (258). Other probe designs were

VOL 40, NO. 5 , APRIL 1968 0 353 R

Page 9: X-ray absorption and emission

discussed in our previous reviews. Commercial X-ray probe attachments were used to investigate thin mineral sections (314) and electroplated diffu- sion couples (545).

LOW-ENERGY X-RAYS AND ELECTRONS

Low-Energy X-Rays. The low- energy X-ray region is becoming in- creasingly important as the character- ization of materials becomes more sophisticated. For many character- ization problems, elemental analyses must be supplemented by information regarding valence, oxidation state, and coordination. Information of this type can be derived from changes in the shape and energy of X-ray band and line spectra. A good example is the de- tailed study on sulfur for clinical in- formation (672, 673). Research in the lowenergy X-ray region has been limited to a few key investigators; however, the number should increase rapidly as the essential instrumentation is now commercially available.

Progress in instrumentation and ap- plications of low-energy X-rays is summarized in a special issue of the Norelco Reporter (20'7, SIO) . Instru- mentation for samples in a gaseous phase was designed by Deslattes and LaVilla (181). Relative intensities of L and 11 spectra in the 2 to 85 range were determined by Davidson and Wyckoff (1 76) .

Holliday ($57, 328) has made very careful measurements in the low energy X-ray region to relate wavelength shift and intensity profiles of band spectra to the bond strength. The change in shape and energy of the carbon K band was used to identify carbon precipitated in iron, carbon dissolved in iron, and carbon combined with iron as Fe3C. The measurements were obtained with a high-resolution focusing spectrometer having a curved blazed replica grating. Because emission bands are more sensi- tive to bonding than to structure, spec- tral data will supplement diffraction. For example, although strontium ti- tanate and titanium dioxide are struc- turally different, their emission band spectra indicate that the Ti-0 band is similar in the two compounds.

Baun and Fischer measured low- energy X-ray spectra using electron excitation and nonfocusing X-ray optics with oriented soap films as the ana- lyzer. Their very extensive studies in- clude spectra of the following elements and their compounds: boron (232, 2S5), carbon (238), nitrogen (238), and aluminum alloys (38, 231, 2S4- 236, 2391, and first series transition ele- ments (269). As they accumulate large numbers of spectra, Baun and Fischer are beginning to formulate rules regard- ing changes in intensity and peak shape as a function of chemical state. For

DYSPROSIUM

30' Takeoff

M a

\.A 9.63 9.40 9.20 I ~ I ' I ~ I ~ I ' I ' I ' I

eV 1280 13CO 1320 1340

Figure 2. Dysprosium M a and M/3 emission spectra as a function of elec- tron energy (237)

example, in the aluminum binary alloys the aluminum E; band position and the aluminum Kar/Kar intensity ratio are linearly dependent on alloy composi- tion (239).

One reason progress in interpretation of spectra has been slow is the poor agreement between investigators. For example, Merritt and Agazzi (452) found that the sulfur L bands they measured by X-ray excitation differed markedly from the band spectra meas- ured by Fischer and Baun using elec- tron excitation. Although some of the conflicting data in the literature can be attributed to sample decomposition using electron excitation, the principal reason for the differences in measured spectra is probably self-absorption of low-energy X-ray lines. The depth at which X-rays are generated is related to the energy of the incident electrons or X-rays. Changes in the takeoff angle significantly affect the "effective" depth from which the X-rays can escape (40). The effects of variation in energy and takeoff angle were very pronounced for the Copper LIlr band spectra. Spectra were measured for energies ranging from 1.4 to 10 keV and takeoff angles ranging from 1" to 70". A more ex- treme case of self-absorption exists in the Mol and M p emission lines of the rare earth elements (237). Fischer and Baun demonstrated that the com- plicated structure reported in the earlier literature is a result of the mode of measurement rather than a true characteristic of the M spectrum. Fig- ure 2, taken from their paper, shows that as the electron energy (and hence depth of penetration) is reduced, the spectrum shows less structure. At a high take- off angle (30") and low voltage (1.5 kV) both the M a and M p are simple line

spectra. The complex structure ob- served at low takeoff angles and high electron energy results from self-absorp- tion and a complex absorption edge structure. For future publications, we urge authors to give their operating parameters in detail so that data can be critically compared by other investiga- tors. Also the data should be obtained under experimental conditions that mini- mize self-absorption.

High-resolution absorption techniques can also be utilized to gain information regarding bonding. Xzaroff discussed the application of low-energy absorp- tion methods to the study of alloys (30). White and RlcKinstry (669) measured the K absorption fine structure of 40 simple oxides of six elements. They found the following factors to be most significant : bond character, nearest neighbor environment (primary coor- dination number), and valence. Long- range ordering apparently has little or no effect on the fine structure.

Excitation by Heavy Particles. Al- though excitation by protons and alpha particles has not been applied t o many analytical problems, these techniques offer several significant advantages over electron excitation. Efficiency of X-ray production by proton excitation increases with de- creasing X-ray energy. Also the bremsstrahlung radiation is reduced by a factor of the square of the electron mass to that of the proton or alpha particle. Therefore excitation by heavy charged particles should yield essentially monochromatic low-energy radiation (86, 370, 435, 567, 611, 612). Production efficiency for lowenergy X-rays can be calculated from the fol- lowing equation:

(2)

where N = X-ray yield in photons/

N = kK.~,jIZ-6.82 exp (0.062 E,)

proton, kx = 0.192, k~ = lo2, k v =

3.4 x 108, and

E , = proton energy, keV.

The line-to-background r?tio for copper L a to background at 3.5 h is 37,000 to 1 when filter attenuation and counter efficiency are considered (61 2).

The thick-target X-ray yield was found to be a function of the crystallo- graphic orientation of single-crystal samples (371). The single-crystal yield exceeded the polycrystalline sample yield by 30% a t certain orientations. For single crystals of copper, the largest observed maximum-to-minimum yield was 15 to 1 in the vicinity of the 001 direction. Channeling of low energy protons is strongly related to the crys- tallographic orientation of the sample. The sensitivity of the X-ray yield to orientation suggests that this technique will provide significant information re-

354 R * ANALYTICAL CHEMISTRY

Page 10: X-ray absorption and emission

garding the interaction of positive ions and ordered arrays of atoms.

Surface chemical analysis by alpha particle bonibardnient recently received world-wide attention when the first in situ lunar analysis was performed. The instrument designed by Turkevich et al . (640) utilizes the variation in back- scatter of monoenergetic alpha par- ticles with matter as a function of atomic number. The energy spectra of backscattered alpha particles from cu- rium-242 were measured with semi- conductor detectors. Other detectors measured protons from CY, p reactions.

Surface density of very thin films can be determined by proton excitation techniques. Thin films of aluminum, copper, and ytterbium were determined using the instrumentation shown in Figure 3 (146, $69). The X-ray yields from the unknowns were compared with those obtained from films of known thickness. Using a 10-p-4 current inci- dent on a thick aluminum target, a typical detection system would record 10,000 counts per second with a counter signal-to-noise ratio of io4. ;\t a signal- to-noise ratio of unity, the calculated surface density is 0.005 pg/cm2. The range of surface density that can be measured by proton excitation spans four orders of magnitude. Lower limit of the surface density measurement is established by the magnitude of the proton capture cross-section and the counter background. The upper limit is a function of the proton energy.

Auger and Photoelectrons. -4uger and photoelectron spectroscopy are excellent complementary methods t o loiv energy X-ray spectrography. These techniques have been known for many years, bu t found very limited application because of ex- perimental difficulties. Rapid growth is predicted because simple reliable electron spectrometers will be avail- able a t a price competitive with low-energy X-ray spectrometers. Low- energy electron zpectroscopy can be used to determine composition of layers as thin as one tenth of a monolayer. Depth of penetration is usually less than a few hundred A; the depth can be varied by changing the energy of the exi t ing radiation and the takeoff angle. All elements above beryllium are de- tectable and the method has high sensi- tivity, particularly if the element sought tends to segregate on the surface. Semiquantitative and qualitative anal- yses are readily obtained; however, quantitative results are difficult to achieve because of the problems in- herent in preparing ultra-thin samples and standards.

When an atom is excited by electrons, the atom can return to the ground state by emission of characteristic X-rays or by a radiationless process in which Auger electrons are emitted (102, 21'7,

221). The energies of Auger electrons are specific for the element but not so well defined as X-rays. The observed huger spectrum consids of compara- tively broad peaks of slightly leas energy than the transition energies of the atoms. Although these peaks are broad, the -4uger spectra look very promising for determination of low atomic number elements. The Auger electron yield is very high for low atomic number ele- ments, whereas the X-ray fluorescent yield is Ion. Experimental difficulties for low-energy X-rays and Auger elec- trons are comparable. Because of the low energies used for escitation and observation, .4uger analysis provides information about extremely thin sur- face layers. This loiv penetration pro- vides information on surface segregation, surface contamination, and diffusion in solids (289-291 ). Instrumentation for .4uger spectroscopy, shown in Figure 4, consists of an electron gun, sample holder, electron-energy analyzer, and electron multiplier. The system is evacuated with sorption-ion pumping and sealed with metal gaskets to avoid organic contamination. Because of the thin layers being examined, cleanliness of the vacuum and surface preparation of the sample are very important (291).

In photoelectron spectroscopic chem- ical analysis (ESC-A), low energy X- rays such as aluminum KCY are used to eject photoelectrons from the sample surface (218). The photoelectron energy is given by the folloiving rela- tionship :

Ephotoeieetron = Ex-ray photon - E b i n d l n g energy

E w o r k function o f spectrometer housing material (3)

Therefore, the photoelectron energy is a function of the binding energy of the atom for the ejected electron. Be- cause this binding energy varies ith chemical state, photoelectrons can be used to determine valence and olidation state. These changes in binding energy are easier to detect by photoelectrons than by X-rays for the following reason: In X-ray emission the X-ray photon energy represents the difference in energy between two levels, whereas the photoelectron energy represents di- rectly the change in binding energy. ;Ilthough there may be relatively large changes in binding energy between K and L electron levels, there will be only a small change in X-ray energy if the shifts are compaiable and in the same direction. In contrast, using ESC;\, a change in binding energy of several electron volts is easy to detect. For example, photoelectrons for Sz- and S6& in sodium thiosulfate are easily resolved. -4uger spectra give addi- tional information; two lines with a 4.3-electron-volt separation for S2- and S6+ nere observed (218). ESCA tech-

PROTONS I

COLLIMATORS 1 I I

Figure 3. tion instrumentation ( 7 46)

Schematic of proton excita-

niques can be applied to E; shell photo- electron emission of low Z elements (219) and to L and 11 shell emission for medium and high Z elements (129, 620, 481). Some characteristics of ESCA are: Electron binding energies of inner shells increase with increasing oxidation number; all three levels, K, LI and L I ~ , ~ ~ I , have an energy shift of approxi- mately 1 eV per degree of oxidation, and shifts are approximately the same re- gardless of the cation-e.g., potassium+

Table VII. Energy Dispersion Instrumentation and Applications

Instrumentation Detectors (64, 83, 105, 296) Filters (49, 91, 133, 198, 199, 285, 383,

548)

492, 531, 536, 565, 622, 633, 666) General (67, 82, 110, 123, 126, 440,

Principles (110, 438, 532) Radiation safety (21, 492, 637) Sniirres " _ _

Alpha (566, 637, 641 ) Beta (1 09, 21 1 , 409, 437, 622) General (21, 357, 515, 566, 696, 622,

6.41. 6 6 1 4 6 6 ) Spectral convolution (9, 66, 271, ,276,

295, 565, 676, 637)

Alloys (56, 534, 636) Cement (534, 641) Coal and coal ash (57, 108, 363, 470,

534, 535, 638) Coating thickness and composition (58,

11 0, 138, 363, 434, 463, 529, 638, 666) Foods (57) Gases (615) General (61, 385, 439, 491) High purity elements (593) In situ ore analysis (2, 9, 455, 568) Low atomic number elements (133) Mail sorting (168, 544) Metal identification (89, 351) JIicroanalysis (343) Ores (66, 82, 1.84, 126, 158, 169, 170,

455, 478, 479, 492, 633, 534, 565, 637, 666)

Petroleum and hydrocarbons (21 0, 492) Slurries (1 21, 122, 124-1 26, 610) Solutions (57, 386, 670)

Applications

VOL 40, NO. 5 APRIL 1968 355 R

Page 11: X-ray absorption and emission

P TR A lo O 0 PE

ELECTRON EMITTER FOR SAMPLE HEATING

MULTIPLIER

-+ - Figure 4. Schematic of Auger electron spectrometer (291 )

as compared to sodium+-when anions are the source of photoelectrons.

Instrumentation for photoelectron spectroscopy is similar to that for Auger spectroscopy, the difference being that X-rays are the source of excitation in ESCA. In one arrangement (216) radiation from the X-ray tube is filtered with aluminum foil before striking the sample. Photoelectrons from the sample leave through a defining slit into the spectrometer. By varying the current in the spectrometer coils, elec- trons of a selected energy are brought to a focus a t the detector slit. The coil current is varied step-wise and the photoelectron pulses are stored in a multichannel analyzer. Instrumenta- tion for a permanent magnet ESCX spectrograph was described by Fahlman and Siegbahn (222). Recent techniques for producing electron beams with narroiv energy resolution and various methods for measuring these energies are summarized by Klemperer (388).

ENERGY DISPERSION X-RAY ANALYSIS USING RADIOACTIVE SOURCES

During the past two years there has been a very significant increase in in- strumentation and applications of X- ray analysis using isotopic X-ray sources coupled with energy dispersion tech- niques based on electronic pulse ampli- tude discrimination and selective X-ray filters. Progress in various countries was summarized in the following re- ports-Australia (666), France (440), Japan (363), Poland (491), and the Cnited Kingdom (21 ) . In the United States, the research and development of isotopic X-ray analyzers has been accelerated by the strong support of the Division of Isotope Development of the

C O L L I M A T O R

@ \ C R Y S T A L 7

r, A M P L E

DETECTOR J’ il i

DETECTOR Y

ENERGY DISPERSION WAVE L E N G T H D I S P E R S I ON

Figure 5. and energy dispersion (66)

Comparison of X-ray spectrometer optics

Atomic Energy Commission. Major symposia on uses of low-energy X-ray sources were held in Warsaw, Poland (348), Chicago, Ill. ( J 4 ) , and Austin, Texas (35). General review papers were prepared by Campbell (115), Holynska ( @ I ) , Martinelli (43S), and Rhodes (530). Publications on var- ious aspects of instrumentation and application are listed in Table VII.

In conventional X-ray spectrography the sample is subjected to a very intense X-ray flux of approximately 10’3 pho- tons per second. The resultant fluo- rescent X-rays are dispersed by a crys- tal analyzer (see Figure 5 ) . This wave- length dispersion technique gives excel- lent spectral resolution, but the geo- metrical losses and low diffraction effi- ciency reduce the X-ray intensity by a t least lo6. The fluorescent X-ray spec- trograph requires a stable 2- to 3-kW power supply, a precision goniometer, and an electronic readout. A moder- ately priced spectrograph costs 15 to 20 thousand dollars. Energy disper- sion systems using a radioactive iso- topic source can be very simple, as shown in Figure 5 . This basic system may be augmented by filters placed either between the source and the sample, or between the sample and the detector. The detector can be a gas- filled proportional counter, a scintilla- tion counter, or one of the new lithium- drifted silicon or germanium detectors. An instrument using proportional or scintillation counters costs two to four thousand dollars; with the lithium- drifted detectors, the cost is increased by a factor of two. The photon flus available from isotopic sources is in the IO6 to IO8 range. Because of the close coupling of the source-sample-detector

assembly, the overall collection effi- ciency is approximately 1%. There- fore, isotopic sources provide useable intensities for energy dispersion anal- ysis.

There are three types of isotopes used for energy dispersion analysis-alpha, beta, and gamma emitters. Alpha emitters such as polonium-210 and curium-242 are used to excite low-energy X-rays. They offer the advantage of high signal-to- noise, but are potent health hazards. Beta emitters are normally used to gen- erate bremsstrahlung plus characteristic X-rays that collectively excite fluo- rescent radiation from the sample. These sources may be in the form of a thin layer of the isotope on a suitable target material, or a mechanical or chemical mixing of isotope and target. Pruess et al. (525) compiled extensive data on three beta emitters-pro- methium-147, calcium-45, and phos- phorus-32.

Sources that decay by electron cap- ture yield essentially monoenergetic radiation, e.?., cadmium-109 emits silver K radiation. By selecting an isotope whose characteristic radiation just exceeds the absorption edge energy of the element being determined, high signal-to-noise ratios can be achieved. High-energy gamma emitters are usu- ally used in a source-target configu- ration where the gamma radiation ex- cites lower energy X-ray5 character- istic of the target. These X-rays are then utilized to excite X-rays character- istic of the sample.

“The Isotope Index” (596) is an annual listing of source suppliers and prices. Detailed information on source design and fabrication of special sources is available from various companies engaged in source development. Cata- logs of spectra of various isotopes have been compiled that are a valuable aid for selecting a source for a particular application (85, 294, 515). The Isotope Information Center a t the Oak Ridge Sational Laboratory provides assistance in obtaining information regarding the availability of isotopes. Their excel- lent quarterly publication “Isotopes and

Sources.

356 R ANALYTICAL CHEMISTRY

Page 12: X-ray absorption and emission

,SAMPLE 60 I I I

P A 2 BAND

15 20 25 30 35 40

X - R A Y E N E R G Y , kev

DETECTOR W I N D O W

A

dSAMPLE ANNULAR ARRAY

C O F SOORCES

S C I N T I L L A T I O N X - R A Y DETECTOR FILTER F ~ C O U h T L R

VilNDOW

B

Figure 6. Central and annular source geometries (530)

Radiation Technology” reviews prog- ress in industrial and research appli- cations of isotopes.

T n o soul ce-sample-detector geome- tries used ~ i t h beta, gamma, and X-ray emitting isotopes are shoivn in Figure 6. The central source arrangement is the one most M idely used in radioisotopic X-ray analysis. The important param- eters are the sample-source-detector distances and the relative sizes of the three components. The X-ray filters are usually placed between the qource and the detector \\indow. Using the central source geometry, overall effi- ciencj is lo-* to lO-‘so that counting rates of lo3 to IO5 counts per second are obtained from pure elements. Shield- ing is provided by a shutter and by the sample being analyzed.

;inother useful geometry is the an- nular source in ahich the sources are arranged in a doughnut-like array around the outside of the detector window. This type of source arrange- ment is necessary to prevent the source from blocking excited radiation from the sample reaching the detector.

Source-target assemblies are used n i th beta and gamma emitters to give a characteristic spectra of the target ele- ment. This target element is selected so that the energy of its principal X-ray line just exceeds the absorption edge of the element to be determined. The source, a high-intensity gamma emitter, is positioned in a cup formed by the target element. The high-energy gamma radiation from the source excites X-raj s characteristic of the target element These characteriftic X-rays superimpoied over a acattered gamma background are the source of excitation.

Resolution. The resolution in en- ergy dispersion techniques is provided by Ross filters, a detector whose out-

Figure 7. Balanced filters for Tin K a radiation (82)

put pulse is proportional t o the photon energy, or some combination of the two. The Ross filter in combination with a low-resolution detector-the scintillation counter-is the system used for most energy dispersion appli- cations. Instrumentation of this type is available from several manufacturers. Other instrument manufacturers have adapted Ross filters for use with propor- tional counters. These balanced (Ross) filters were developed 30 to 40 years ago (385, 548); however, they were not re- quired for conventional X-raj spectrog- raphy utilizing crystal spectrometers. The balanced filters generally consist of two thin metallic folds that have absorp- tion edges on the low- and high- energy side of the X-ray spectral line of in- terest. For example, the filters for tin K a radiation are thin sheets of silver and palladium (see Figure 7 ) . The energy of the tin K a line just exceeds the K edge of palladium, a strong abforber of tin K a , while the tin K a radiation is highly transmitted by the silver. The thickness of the two filters is carefully controlled so that their ab3orption characteristics are similar for all X-rays except those in the narrow pass band.

The difference in measured intensity, using first the silver and then the pal- ladium filter, is related to the tin con- tent of the sample. In general, the balanced filter technique is limited to major, and in favorable cases, minor constituents, as the analytical line in- tensity is a small difference betneeri two large intensities. Any spectral line whose energy falls within the pass band is a potential source of error. The Ross filter is a single-element analyzer; there- fore, each element requires a unique set of filters. The Ross principle is eaiy to apply and can be used n i th broad spectrum sources and wide band detec- tors.

Broquet, Robin, and T’acher (91) pre- sented an ewellent discussion on filter preparation, choice of filters, and pos- sible spectral interferences. They pre- pared filters by mechanically rolling metallic foils, chemical etching, elec- trodeposition, and encapsulation in

plastic. Preparation of foils for the 1- to 15-keV region is discussed by Halliday et al. (286). Other researchers have prepared filters of strontium (49) and filters for low atomic number elements (198, 199). The low atomic number filters were dried slurries of the pow- dered compounds plus polystyrene. The use of gases for X-ray filters was investigated by Castaing and Pichoir (133) for the nondispersive analysis of low atomic number elements. Their filter assembly is a cylindrical container closed a t both ends by collodion win- dows. Pressure of the circulating gases can be continuously adjusted to vary the transmission of low-energy X-rays.

During the past two years, the lith- ium-drifted silicon and germanium detectors became commercially avail- able. The high resolution provided by these detectors makes it possible to achieve multi-element analysis using energy dispersion techniques. The re- solving power of various detectors is compared n i th spectral resolution by Rosi filters and crystal diffraction in Table VI11 (103). The resolution of adjacent spectral lines is proportional t o the dispersion and inversely propor- tional to line width. To compare res- olution achieved by various techniques, a figure of merit, R, was formulated that is equal to the separation of the peaks of characteristic Ka lines of adjacent atomic number elements divided by the line width at one-half maximum inten- sity. For Ross filters, the line width corresponds to the pass band. The resolving power of conventional flat- crystal optics was evaluated for typical collimator-crystal combinations. Four sets of spectral lines were evaluated covering X-ray energies from .ilE(al, 1.49 keV, to - iuKal , 68.8 keV. In the soft X-ray region, <5-keSr crystal diffraction is 50 to 100 times superior in resolution to either Ross filters or pulse amplitude discrimination using flow- proportional counters. For medium- energy X-rays, 5 to 20 key, crystal diffraction is 2 to 20 times superior in resolution to lithium-drifted silicon; the difference in resolving power between

VOL. 40, NO. 5, APRIL 1968 e 357R

Page 13: X-ray absorption and emission

diffraction and lithium-drifted silicon decreases with increasing energy. In the high-energy X-ray range, >50 keV, the lithium-drifted silicon detector re- sults in higher resolution than can be ob- tained by conventional flat crystal optics. Analyzing crystals with very small d-spacing and high reflectivity are not available so that pulse amplitude discrimination using a lithium-drifted detector and balanced filter techniques are recommended for evaluation in the high-energy X-ray region.

Applications. The principal prob- lem in conventional X-ray spectrog- raphy-the matrix effect-is equally important in energy dispersion. When the sample is analyzed in the laboratory and the sensitivity is adequate, the matrix effect can be reduced or effectively eliminated by dilution. For in situ analysis, or when sample handling is to be min- imized, alternative methods are re- quired. Probably the best approach is to use the intensity of backscattered X-rays as a means for matrix correction. Although there have been many success- ful applications of hackscattered X- rays, the analyst must first establish the validity of this approach for his partic- ular problem. Several theoretical and semi-empirical formulas have been de- rived to describe the relationship be- tween the properties of the scattering medium and the gauge geometry (Z'), Lubecki et n l . (420) found that Compton scatter behaved similarly to fluorescent X-rays and could be used for matrix correction.

Other analytical problems in conven- tional X-ray spectrography such as particle-size effect, surface preparation, and chemical effects are also present i n energy dispersion, but to a different degree. The use of high-energy K series X-ray lines minimizes variations in intensity duc to surface roughness or

particle size because the penetration of the characteristic X-rays has increased from microns to millimeters. In the soft X-ray region, peak shifts resulting from chemical effects will not be ob- served because of the much poorer resolution of the energy dispersion method. Obviously, this poorer resolu- tion is not always advantageous. There are many limitations to applications of energy dispersion imposed by inade- quate resolution of spectral lines, partic- ularly when determining low concen- trations.

Energy dispersive X-ray systems are being used for many of the research and control analyses that were provided by conventional X-ray spectrographs. The acceptance of these new techniques is demonstrated by the large number of applications listed in Table VII. These applications range from in situ analysis of the lunar surface to the meat-fat ratio of animals. Industry is beginning to use these simple instruments for widespread quality and process control analysis. X-ray emitting isotopes, pro- duced by neutron activation, ran also be used for encrgy dispersion analysis; for example, K capture isotopes emit ra- diation that is specific for the element being determined (505, 571).

Following the excellent introductory paper by Bowman et al. (83) a number of publications have described energy dispersion applications of the semi-con- ductor detector (298, 530, 344, 356, 533). For isolated microgram quan- tities of elements deposited on filter papers the limit of detection is the 10- to 100- microgram range. Limits of detec- tion for samples as powders, solids, or solutions, are in the order of 100 ppm. Lower detection limits can be achieved by using isotopic sources of higher strength, improved source-sample-de- tector geometry, and longer counting times.

~

Table VIII. Comparison of Spectral Resolution by Diffraction and Energy Dispersion Techniques

D W"2

R = -

Jectral Energy, Crystal lines keV diffraction

AlKcvi SiKw NiKal CuKcri PdKai AgKw PtKai AuKoli

1.49 1 .74 7 .48 8.05

21.18 22.16 66.83 68.80

43."

12.b

1 . o c 2 .3b

Sci nt il- Li-drifted Proportional lation Ross

silicon counter counter filter . . . 0 . 3 . . . 0 . 9

1 . 0 0 . 5 0 . 2 1 . o 1 . 1 0.5 0 . 2 1.0 1 . 3 0 . 4 0 . 2 1 . 0

a EDdT crystal - coarse collimation 0.8'28 = TY1'2. * LiF crystal - fine collimation 0.3"28 = Wi/z . c LiF crystal - fine collimation 0.3'28 = W 1 / 2 2nd order lines were used. D = distance between K a peaks for adjacent atomic number elements. W ' Z = width of peak at l / ~ maximum intensity. D and TY are expressed in 28 for crystal diffraction and keV for energy dispersion.

JYe predict a very rapid increase in the application of energy dispersion X- ray techniques using radioisotope ex- citation sources. This increase will be a result of the advantages offered by these techniques : lower cost, excitation selec- tivity, and stability, portability, and simplicity of operation. These new instruments cost 2 to 5 times less than conventional X-ray spectrographic equipment: therefore, they can be pur- chased economically for specific prob- lems. There is the opportunity for much greater selectivity in excitation conditions as numerous isotopic sources are available a t moderate cost. The isotopic sources eliminate the need for voltage and current stabilizers and the electrical and water requirements of the conventional sealed X-ray tube. The battery-operated energy dispersion sys- tems are compact lightweight instru- ments; thus, the portability can be used to advantage in many applications. Finally, the simplicity of operation should increase the utilization by loner skilled personnel working in metallur- gical, chemical, and mining industries and in clinical laboratories.

ELECTRON PROBE MICROANALYSIS

In the past two years significant prog- ress has been made in defining and characterizing the parameters that are important in relating measured X-ray intensities quantitatively to composi- tion. For X-rayo wavelengths of ap- proximately 3 A and shorter, the methods of quantitative analysis are reasonably well defined. In this region analyses to within 2 per cent relative are possible using pure elements as stand- ards, provided mass absorption co- efficients, fluorescent yields, and atomic number parameters are accurately known. The most significant barriers to better analyses are no longer the theories of quantitative analysis but rather the basic physical parameters such as the mass absorption coefficients and the depth distribution of X-ray production required in these theories. Until better values are available, it will be impossible to distinguish unequiv- ocally between the merits of the theo- ries as finer and finer distinctions are made. The same problem is arising in the Monte Carlo and transport equation treatments of quantitative microanal- ysis. Data for use in these equations are simply not sufficiently accurate to determine the agreement between theory and measurements. Thus the evaluation of further advances in these theoretical treatments must await more careful measurements. We can, there- fore, expect a greater emphasis on the accurate measurement of X-ray param- eters in the next few years.

The situation is not so satisfactory foro analytical wavelengths longer than 3 A. The seriousness of the problems

358 R ANALYTICAL CHEMISTRY

Page 14: X-ray absorption and emission

of wavelength shifts, band shapes, self absorption, and variation in transition probabilities is just beginning to be realized. Coupled with the lack of truly accurate maqs absorption co- efficients and other parameters, anal- yses that can be called quantitative are not very often realized. On the posi- tive side, almost all manufacturers have available spectrometers for routine measuremen; of X-ray wavelengths to a t least 50 A. The ease of measuring these wavelengths will stimulate re- search into the factors affecting quan- titative analysis. Indeed, in the past two years the first attempts at defining application and limitations of methods for quantitative analysis using long wavelengths have appeared. Rapid progress can be expected.

This emphasis on the use of longer and longer analytical wavelengths has placed a greater burden on the operator of an electron probe microanalyzer in that he must know more and more about the physics of X-rays. Many analyses could be in error by a factor of 2 or more because of improper opera- tion of the electron microprobe, unsus- pected wavelength shifts, or the use of inapplicable calculation methods. More thorough training must be avail- able to ensure that gross errors are not committed by inexperienced microprob- ers. The many users groups and the Electron Probe Analysis Society of ..imerica should take an active role in this educational process.

The use of computers to reduce the manual labor in converting X-ray inten- sities to composition has become com- monplace. Many different programs based on the many published correction equations have been mritten. More and more, automatic data collection systems are being used in connection with electron probe microanalyzers and computer programs. This relieves the operator of the routine operations in connection with microanalysis but at the same time requires a greater dili- gence to ensure that the results have meaning. The danger with these pro- grams is that the arithmetic accu- racy of the computer tends to be equated with the accuracy of the X- ray measurements and the equations used in the program; the results, there- fore, are viewed with much greater significance than they may merit. In- experienced operators particularly are ap t to use such program< as a crutch, which impedes their quest for better understanding of factors involved in quantitative analysis. -i number of neir instruments have

been developed. Mainly these are improved instruments by existing manu- facturers M hich reflert the trend toward modularity of design and simplicity of operation. In recognition of the impor- tance of qualitative analpis , these new

instruments all have excellent beam scanning systems with the ability to display a variety of electron current and X-ray signals with biasing to enhance contrast. The emphasis on long wave- length analysis is also reflected by the fact that spectrometers for detection and measurement of wavelengths to a t least 50 A are available with all of these instruments. Another interesting de- velopment is the appearance of com- mercial instruments combining the functions of an electron microscope and electron probe microanalyzer. Eval- uation of the contributions of these combination instruments must await their more widespread use in the nest few years.

Publications and Meetings. Sev- eral new books on electron probe microanalysis have been published. These are included in the list of books given in Table I. The most im- portant of these is the Proceedings of the Fourth International Confer- ence on X-ray optics and X-ray microanalysis held a t .irsay3 France, in September 1965 (131). This book in- cludes reports of the most significant research in the field of electron probe microanalysis in the past few years, and reflects the continuing high quality of these international meetings and of the published proceedings. Papers pre- sented a t four other meetings have been the subject of separate issues of a journal or will have been published as books by the time this review article appears. Proceedings of two meetings held in Vienna, Austria, in 1964 and 1965 have been published as separate issues of Mikrochimica Acta (456). A number of papers presented a t the First Sational Conference on Electron Probe Micro- analysis have been collected and will be published in the series “Advances in Electronics and Electron Physics,” pub- lished by Academic Press. The re- view papers presented as part of the 69th annual meeting of ASTM in Atlantic City, ?;. J., June 1966, also will be pub- lished as part of a Special Technical Publication of .1STlI ( 1 4 ) . .A brief summary of a meeting on applications of electron probe microanalysis sponsored by the Institute of Metals was given by Swindells (619).

H. l l a l i s a (426) has written a general book on electron probe micro- analysis in German. Heinrich (298) re- cently reviewed this book and comments that its strength lies in the practical approach of the author toward experi- mental details of microanalysis. The treatment of quantitative analysis, how- ever, tends to be descriptive rather than critical. The book by Theisen (630) on quantitative analysis is disappointing. I t presents the equation, for a system of quantitative corrections which he has developed arid lengthy tables to expe- dite the corrections. However, both

typographical errors and errors in the derivations of the equations limit the usefulness of an already limited book. Poole (609) in reviewing the book is particularly critical and warns of pos- sible danger in ready acceptance of the equations and tables. Eliori (209) has also written a general book on electron probe microanalysis. Unfortunately, this book also gives a very biased view, particularly in the section on instrumen- tation. KO effort has been made to compare or even describe the many different types of instruments presently available, which vary widely in their characteristics. Also, discussion of quantitative analysis is rather limited.

For the geologist, Adler ( 5 ) in his book on X-ray analysis devotes several chapters to electron probe microanal- ysis with particular application to geo- logical samples. These are easily understood and well written and pre- sent a good introduction to electron probe microanalysis. Anderson (20) noted that the extensive work of Smith et al. (537,687-690) on the use of stand- ards for establishing quantitative re- lationships in the analysis of silicate minerals was not discussed in ;Idler’s book.

An annual series of conferences was instituted in the United States in 1966, to bring together a t one meeting the many electron microprobe papers which previously were presented a t scattered meetings throughout S o r t h America. At the first conference a t College Park, Md., in May 1966, a committee headed by Dr. L. L. Marton of the Xational Bureau of Standards was commissioned to investigate the desirability of forming an organized society. Impetus was given to this action by the success of the First Conference and the difficulties experienced in organizing such a con- ference without formal backing. The recommendation of the committee to the attendees of the Second Conference in Boston, June 1967, that a Society be organized was approved by a large ma- jority. The Electron Probe -4nalysis Society of America was thus formed. The election of the executive board will have taken place by the time this review is published. The third national meeting will take place in the Chicago area in 1968.

A major problem in electron probe microanalysis continues to be the proper training of operators and of analysts concerned with interpreting the data from electron probe microanalyzers. With the ever increaiing sales of new instruments this promises to be a con- tinuing problem. Education would seem an important area where a signifi- cant contribution could be made by the Electron Probe Analysis Society of America.

Probe users groups now exist in prac- tically every area of the United States,

VOL. 40, NO. 5, APRIL 1968 359 R

Page 15: X-ray absorption and emission

in Canada, in Japan, and in many areas of Europe. These groups have proved a useful forum for the discussion of analytical and instrumental prob- lems. The two major areas which these groups are attacking are the anal- ysis of standard samples to establish reproducibility of results on a variety of instruments and the establishment of performance standards for instruments so that new operators can have some basis for judging how well an instrument is performing (62). Some comments of the Washington probe users group on the pitfalls in the analysis of standard samples were presented at the 69th annual ASTM meeting (14). Reports of the activities of several users’ groups have been given a t the national meetings in College Park and Boston.

Quantitative Analysis. T o relate measured X-ray intensity t o con- centration, corrections must be ap- plied for absorption, fluorescence due t o characteristic lines, and atomic number. Several general discussions of quantitative probe microanalysis have been published in the past two years (18, 23, 28, 66, 480, 498, 579, 694). Smith (587) has recently re- viewed the various factors that are important in theories relating X-ray intensity to composition. A correction for fluorescence due to absorption of the continuum is acknowledged but seldom applied. The rationale used in ignoring a continuum fluorescence correction is that the contribution is a more or less constant fraction of the intensity gen- erated in the sample and pure element standard, or that it is included in the atomic number correction. Up to 15% of the measured intensity from gold a t 30 kV is reported to be due to con- tinuum fluorescence. From the same source, a correction of 6.5% to the calculated composition in InAs is necessary (92). These data would indicate that a more careful evaluation of fluorescence due to the continuum would be fruitful.

Important criteria in quantitative analyses are the sensitivity or limit of detection of a method and the precision of analysis. Ziebold (695) pointed out that far more is involved in the esti- mation of precision and sensitivity than simply counting statistics. One of the major additional factors is the height of the sample relative to the spectrometer. This sample height is extremely crit- ical for instruments in which the sample surface is tangent to the fo- cusing circle for the spectrometer. Zie- bold developed expressions which can be used to estimate sensitivity and pre- cision based on the Ziebold-Ogilvie relation between intensity ratio and concentration. This Ziebold-Ogilvie equation has been used in the analysis of ternary samples (346). Sensitivity of two kinds of instruments have been

compared by .irlt and Bloch (25) based on peak and background meas- urements. They found a very strong dependence of sensitivity on electron voltage. .1 number of evaluations of the cor-

rection procedures have been made in the past two years. These evaluations are based on comparison of known com- positions with those calculated form the measured X-ray intensities. ;ill of these claim to be critical, and most dram conclusions about which correc- tion procedure is best. The signifi- cance of these evaluations must be carefully considered. Some of the im- portant criteria are:

(a) What equations are being evalu- ated and is the comparison made be- tween the most recent form of each equation? Quite frequently evalua- tions are biased by the use of equations which have been modified from an ad- mittedly limited form. -1s an ex- ample, Helgesson (307) compares the absorption correction of Philibert with that of Tong. The modification of Duncumb and Shields to the Philibert equation is not used, although, for the samples containing aluminum, the Duncumb and Shields modification has already been shown to be important.

(b) Are the efferts for which the eval- uation is made the only significant corrections in the sample? Evalua- tions of the atomic number effect have been plagued with errors because un- certainty in the absorption correction due to possible error in mass absorption coefficients completely masks the ex- istence of an atomic number effect. The existence of an atomic number effect for copper in the Cu-Si system as reported by Ranzetta and Scott (517) has been proved because the mass absorption coefficients for CuKa are essentially identical and small for both elements. Unfortunately a possible fluorescence effect by the Kp line of copper was not taken into account and the demonstration of any atomic num- ber effect for nickel in the same system cannot be considered as proven.

(c) T h a t experimental measurements were used for the evaluation? Quite frequently, on the basis of analysis using a single instrument for a single binary System, or even on a single sample, recommendations are given as to which correction procedure is best. Such recommendations can hardly bear any weight a t all as many errors could bias the results toward the equations which are not suitable except for very limited analyses.

(d) K h a t data such as mas9 absorp- tion coefficients, fluorescence yields, etc., have been used in the evaluations? -1gain, because of the u?rertainties in the parameters, comparisons can be biased because of the particular values used. The beat method of circumvent- ing this latter problem would appear to be to compare correction procedures applied to a large volume of data, using a histogram to plot errors. This pro- cedure was first used by Poole (610)

and has since become quite popular (51, 307, 630).

(e) Do the equations that are com- pared really apply to the measurements which have been made? Many com- parisons are made in which the approxi- mate methods such as those of Belk (51) are evaluated for much data for which they were never intended to apply. Beaman (43) has done exten- sive calculations, many of which proved the inaccuracies of equations that were already pointed out in the original papers.

In evaluating the advances made in quantitative analysis, the X-ray wave- lengths should be divided into short- and long-wavelength regions +th the division falling roughly a t 3 A. The choice of this division is predicated by a number of factors. For the short- wavelength region, using the best of the presently available correction equa- tions, analyses to within l or 2% are generally possible using pure elements as standards. The absorption correc- tion is limited to moderate values by the largest mass absorptign coefficient for wavelengths up to 3 -4. is approxi- mately 1000. Finally, 3 A represents the longest wavelength for which efiects such as wavelength shifts due to chem- ical bonding may be safely ignored. In the long-wavelength region, lower accuracy must be expected because a whole host of new effects must be care- fully considered. These effects will be discussed in a later section.

Absorption Correction. The ab- sorption correction equation proposed by Philibert and as modified by Duncumb and Shields has become the most widely used absorption correc- tion equation. The form of this equation was given in our 1966 review (117). Evaluations such as those by Beaman (43), Colby and Conleg (154), and Heinrich (301) support the view that this equation is the best currently available for quantitative analysis in the short-wavelength region.

J. V. Smith (587) has evaluated the use of various absorption correction equations for quantitative analysis of mineralogical specimens. For elements of atomic number greater than Si in the Periodic Table, p d hence wavelengths shorter than 7 A, he recommends the m e of Philibert’s equation or f ( x ) tables.

Adler and Goldstein (6 , 7 ) have pre- pared tables of the modified Philibert equation, so that this absorption cor- rection can be applied quickly by finding two values in the tables. Similar tables have been prepared by Ranzetta and Scott (520).

Theisen (629, 631) proposed alter- nate parameters for u and h in Phili- bert’s equation. These values are

8.9 x 105 ,J = ~-

(Eo - E,)* (4)

360 R ANALYTICAL CHEMISTRY

Page 16: X-ray absorption and emission

where E , and E, are the electron energy and absorption edge energy, respec- tively, and

(5) Eo2 A

(E , - E J 2 5 h = 1.5308-

where A and Z are atoniic weight and atomic number.

Theisen supports the use of these parameters on the basis of agreement known and calculated compositions for data from over 100 samples of published data. It is unfortunate that the errors and inaccuracies in his book (630) have tended to discredit this correction equa- tion so that few evaluations have been made. Beaman (43) rates the Theisen equation as quite low in accuracy.

In Russia, Il’in and Loseva (345) have proposed an absorption correction based on a concept of an effective depth for X-ray production which is an exten- sion of a similar concept of Kupriyanova (397). The form of this proposed cor- rection is that

K A = C A f i

where K A is the ratio of the measured X-ray intensity of a characteristic line of element A in a sample to the inten- sity in the pure element A ,

Cn is the concentration of element A ,

and

f, is given by Equation 7:

In this equation x i and x i are the product of mass absorption coefficient and cosecant of the X-ray take-off angle for sample and pure element, respectively. The factors z& and x& are the effective depths of production of X-rays. If it is assumed that the effective depth has the same value x* in the sample and pure element, then it can be evaluated from the intensity ratios (KA’s) for the KCY and Kp lines for the same element, and f i can be writ ten

f1 = exp ( [ x i - x i 1 z*) (8) An identical linear relationship was

found between the value of x* and overvoltage for two iron-nickel samples with x values which differed by a factor of 2. The equation found for relating z* to overvoltage in the iron-nickel system was

X* = 0.194 X (E, - EA) (9)

where E , and EA are the electron volt- age and the excitation potential, re- spectively. Il’in and Loseva claim that this absorption correction can be applied to any sample with x less than 1000 using the above equation for effec- tive depth. For samples in which x is greater than 1000, the effective depth

may be determined from any sample of known composition whose x is close to the unknown.

The accuracy of the absorption equa- tions can be evaluated by comparison with more fundamental data. The values of f(x) can be measured as a function of x by measuring the X-ray intensity as a function of take-off angles. T o place these values on a n absolute basis it is necessary to extrap- olate to x = 0. Heinrich (301) pointed out that a plot of l/f(x) against x is a better method of extrapolation than the log f against x usually used.

Taylor (626) has measured f(x) curves for aluminum and copper a t several electron voltages in a geometry in which the sample surface is not per- pendicular to the electron beam. By rotation of such a sample about an axis parallel to the electron beam, the take- off angle can be varied. His results do tend toward the values predicted by the modified Philibert equation as the elec- tron incidence angle approaches 90 degrees. No analytic method for using the Philibert equations a t non-normal electron incidence is given.

Wittry and Andersen (679) have evaluated measured values of f(x), excluding those for which the electron incidence is not normal to the specimen surface. They find a systematic de- pendence of f(x) on accelerating volt- age, atomic number, and excitation ratio, E,/EA. By plotting f(x) on an appropriate scale, extrapolation to small values of f(x) was possible for use in the long-wavelengt h region,

The absorption correction can also be calculated if the number of X-rays produced as a function of depth in a sample is known. The sandwich sample technique originally used by Castaing and Descamps (130) provides the means for such measurements of this distri- bution (d (pz) curve).

During the past two years, four groups of measurements have been made. Castaing and Henoc (138) mea- sured curves for aluminum a t five electron voltages using magnesium as the tracer element. The f(x) values obtained from these 6 (pz) curves differ by several per cent from the f (x ) values calculated from the modified Philibert expression for the A1 K a line. Shimizu, Murata, and Shinoda (575) measured (pa) curves for a zinc tracer in copper a t electron voltages ranging from 24 to 37 kV in two different electron probe microanalyzers which had different take- off angles. f(x) values were not calcu- lated from these curves for comparison with the modified Philibert equation. Vignes and Dez (653) measured 6 (pz) curves for titanium using a vanadium tracer and for lead using a bismuth tracer, again a t several electron volt- ages. For these somewhat shorter wavelengths, good agreement was ob-

tained with the modified Philibert expression. 6 (pz) curves for zinc tracer in copper

a t several electron voltages were also measured by Brown (Q6), but in an instrument in which the electron beam was incident on the sample a t an angle of 60 degrees. Using the geometrical factor to take into account the reduced depth of penetration in the inclined sample, the curve measured at 27.5 kV was in good agreement with the orig- inal 29 kV curve of Castaing and Descamps (f30). The f(x) values cal- culated from the 6 (pz) curve at 27.5 kV agree to within 1% of the modified Philibert equation, provided the x values are multiplied by the factor (1 - cos2 8) where 8 is the angle be- tween the electron beam and normal to the sample surface. At lower electron voltages, this factor will no longer bring values from the modified Philibert equation a t normal electron incidence into coincidence with values at non- normal electron incidence. This diffi- culty in using the absorption correction equations should be recognized by those having electron probe microanalyzers in which the sample is tilted relative to the electron beam.

Cosslett (160) has used measurements of electron transmission through thin films to generate a 6 (pz) curve for copper a t 29 kV. Good agreement was obtained with the copper curve meas- ured by Castaing.

The most important physical param- eters used in the absorption correction are mass absorption coefficients. Hein- rich and Yakowitz (305) have evaluated the errors associated with the absorp- tion correction and show that uncer- tainties in p / p values are one of the greatest potential sources of error in the absorption correction. T o minimize these errors, they recommend that f(x) values be kept larger than 0.7 by using low electron accelerating voltages and high take-off angles. Kelley (368) also emphasized the importance of accurate p/p values.

Heinrich (302) prepared a table of mass absorption coefficients ( p / p ) based on a computer fit of a logarithmic equa- tion to experimental data. Coeffi- cients to calculate p/p for the various elements were then correlated by wave- length region and atomic number to obtain the best table of p /p values based on available experimental data. This table, the accompanying paper, and an additional discussion of p /p measure- ments by Heinrich (300) have stimu- lated the measurement of p / p values during the past two years. Bearden (43, Hughes and Woodhouse (359), Carter et al. (128), and AlcCrary et al. (446) have all made gxtensive measure- ments in the 1 to 10 A wavelength range with claimed accuracies of 1 to 3%. These authors have provided consider-

VOL. 40, NO 5, APRIL 1968 * 361 R

Page 17: X-ray absorption and emission

able new data, some of which are not in particularly good agreement with the tables prepared by Heinrich.

The appearance of Heinrich’s tables has also stimulated the production of p / p tables using some sort of computer interpolation and extrapolation. Many of these efforts would appear to overlap or a t best be a dubious addition to an already sufficiently confused area. While it is evident, as more accurate p / p measurements are made, that Heinrich’s tables have significant errors in certain wavelength and atomic number regions, it is equally evident that a proliferation of tables can only lead to a completely chaotic condition where any attempts a t evaluating the accuracy of correction equations will degenerate into arguments over which table of p / p values to use. Some sort of coordination in the preparation of these tables would be desirable.

An extensive table of p / p values is being prepared by McMaster et al. (447). This table extends from X-ray energies of 1000 keV down to 1 keV. Frazer (245) has prepared a set of co- efficients for calculating p / ~ values similar to those of Heinrich evcept that a different weighting scheme and addi- tional recent measurements were used in the computer fitting procedure. Taylor (625) suggests that a relation- ship between p / p values of an element for its own radiation can be used as an aid in interpolation. An additional table of values has also been published by Theisen and Vollath (632).

Kelley (368) has prepared a graph from which p / p values for any element for any wavelength can be obtained. Such a graph contains an averaging procedure similar to that used in the computer techniques for obtaining best fit for p / p values. Guttmann and Wagenfeld (277) have calculated p / p values for most elements a t 10 wave- lengths of interest to microanalysts from theoretical considerations of elec- tronic wave functions. These calcu- lated values agree to within about 5% of measured values and perhaps offer the hope that theory may supply accu- rate p / p values.

In the long-wavelength X-ray region, Henke et al. (312) have published a table of p / p values. This table repre- sents the best and almost the only source for coefficients in this wave- length region. The table has been republished recently in the il’orelco Reporter (257).

Fluorescent Correction. The most suitable correction for fluorescence due t o absorption of characteristic lines is a procedure suggested by Reed (523), which is a modification of an equation originally proposed by Cas- taing. This modification to Castaing’s equation will presumably remove the bias a t low kilovoltages which was the

main criticism of Castaing’s equation in an evaluation by Colby and Conley (1 54).

Criss (164) has developed a correction equation stated in terms of the absorp- tion parameter f(x), and specifically has generated such an equation from the modified equation of Philibert for f(x). This kind of equation, which has yet to be evaluated, would free the fluorescence correction from the approximation of the primary 6 ( p z ) curves that is necessary for other types of fluorescence correc- tions.

The distribution of fluorescence radiation as a function of depth in the sample has been measured by Brown (96). By measuring the 6 (pz) curve in a sandwich sample for a tracer ele- ment which is excited by the character- istic radiation of the matrix element, and subtracting the 0 (pa) curve for a tracer element which is not excited by the characteristic radiation of the same matrix element, the distribution of fluorescence radiation is obtained. Using iron, cobalt, nickel, and zinc tracers in copper, the fluorescence dis- tribution was obtained. The same distribution was obtained in a single sample where the tracer element dys- prosium was chosen so that the K a line of the copper matrix could excite the Lal but not the Lfl, line of dyspro- sium. In the same paper, I3ronn gives a computer program that can be used to calculate the fluorescence distribution from a measured primary distribution.

Fluorescence due to characteristic lines can seriously affect results in inhomogeneous samples such as diffu- sion couples or samples containing inclusions of elements which are ex- cited by the characteristic radiation of the matrix. Smith (587) has reviewed attempts to evaluate the contribution of fluorescence in the context of the large inhomogeneities usually experi- enced in mineral samples. Maurice, Seguin, and Henoc (444) havc investi- gated the effect of fluorescence due to characteristic lines on the results from diffusion couples. Calculated values were compared with experimental curves from couples prepared by placing two metals in contact, one of which is capa- ble of exciting the characteristic lines of the second. Reed (524) has con- sidered the effect of fluorescence effects on spatial resolution of electron probe microanalysis.

For homogeneous samples, Heinrich and Yakovvitz (306) have evaluated the errors introduced into quantitative analysis by possible errors in the many parameters which are necessary in the fluorescence correction. The most sig- nificant source of error is introduced by uncertainties in the fluorescent yield values. Most other errors can be ex- pected to affect the calculated com- position by 0.1 to 0.2% of the amount

present. Fink et al. (118) have re- cently reviewed the status of measure- ments of fluorescent yields.

Fluorescence due to absorption of continuum radiation has been studied by Afonin and Pavlinskii (10). They claim that up to 207, of the intensity of .4gKa line is generated by absorption of continuum radiation for an electron accelerating voltage of 40 kV and com- pare experimental results with calcu- lations from an equation derived in the paper. Hink (316) has measured the contribution due to continuum fluo- rescence in copper and tungsten. Sim- ilar magnitudes to that of Afonin and Pavlinskii for the continuum fluo- rescence were observed.

Atomic Number Effect. The greatest effort in quantitative analy- sis during the past two years has gone into understanding and characteriz- ing the atomic number correction. Significant progress has been made. From a situation in which it was frequently argued tha t the atomic number correction was only the result of uncertainties in mass absorption coefficients, the existence of an atomic number correction is universally ac- cepted and the physical basis of this correction is known.

Castaing was the first to propose what has become known as the atomic number effect. In his second approxi- mation, the ratio Kal of intensity gen- erated within the sample compared to that generated in the pure element was related to concentration Ca by the equation

where and as are constants. The values of these factors depend on atomic number and electron accelerating voltage, and the ratio aa/as is in- creasingly important with increasing difference between the average atomic number of sample and pure element standard. The origin of this dependence on atomic number is that the number of characteristic X-rays generated per incident electron for a given concen- tration of an element in matrices of varying atomic number is not constant as a result of differing backscattering and electron retardation properties of different elements. Thus the a co- efficients can be written as

s R

a = -

where S is related to the stopping power of an element and R is a backscatter coefficient which takes into account the loss of ionization in the sample as a re- sult of the energy carried off by back- scattered electrons.

The differences i n the proposed atomic number corrections result from

362 R ANALYTICAL CHEMISTRY

Page 18: X-ray absorption and emission

different methods of evaluating S and R . Duncumb and Reed (297) have proposed the following method of cal- culatiiig these factors. The stopping power S is defined by

where p is density and dE/dx is the mean change in energy for an electron travelling a distance dx. Stopping power of an element is approximately constant for a particular element re- gardless of its physical or chemical state. The most suitable formula to date for stopping power is

S = const. - - In (l'lJGiiE) - A E (13)

where J is the mean ionization poten- tial. Duncumb and DaCasa (194) have used J as an adjustable parameter to improve agreement between ob- served and calculated compositions. A table for J as a function of atomic number for this best fit can be found in the paper by Duncumb and Reed (197).

If the electrons were backscattered with no loss in energy, then the 1 - R would be equal to the electron back- scatter coefficient 7 which is the frac- tion of incident electrons which are backscattered. Because the electrons do lose some energy in the backscatter process the value of 1 - R is less than 7 by an amount which depends on the energy distribution of backscattered electrons.

The factor 1 - R can be calculated from the expression

where Q is the ionization cross-section, S is the stopping power mentioned above.

C7 is the ratio of the electron energy E, to the absorption edge energy EA.

q ( U ) is the number of backscattered electrons n i t h energy greater than E K .

Thiq number can be calculated from measurements of the energy distribu- tion of backscattered electrons. Dun- cumb and Reed (197) have prepared a table of values of R as a function of voltage ratio I: and atomic number Z based on Bishop's measurements (68). These values are for normal electron incidence with the effect of an inclined sample on these values being unknown a t the present time. Springer (605- 607) has taken a similar approach to evaluation of S and R for the atomic number effect, but his R values are based on earlier measurements for elec- tron backscattering. Castaing and Derian (129) have used a special sample

for determining directly the values of 1 - R. A small cavity, 400 microns in diameter and 20 to 30 microns deep, was cut into the surface of a sample. This cavity was covered with a thin layer (approximately 2 mg 'cm2 thick) of the same element. The thin layer was formed by vacuum evaporation. h small hole was made in this thin layer so that the incident electron< could enter the cavity, but then would be trapped, giving up all their energy within the sample. Comparing the x-ray intensity generated in such a sample with the intensity from a normal flat sample allows the direct experimental measurement of the factor 1 - R.

Smith (587) has developed a formula for S baqed on empirical fitting to a large number of standard samples. This formula is

This formula for S was obtained in an Applied Research Laboratories instru- ment and should not be used indis- criminately with other instruments until thoroughly checked. For values of R , Smith uses the values from measure- ments of backscattered electrons of Green. A graph reproduced in Smith's paper can be used to obtain R values for any electron voltage and atomic number. -4 number of evaluations of the atomic

number effect have been made. Be- cause of the possible errors in the ab- sorption and fluorescence corrections, these evaluations usually are based on statistical analysis of a large volume of data in which calculated compoqitions are compared with the known coniposi- tion of standards. The success of any atomic number correction is judged on the basis of how successful the correc- tion is in reducing the difference between known and calculated compositions. Poole (510) has compared several cor- rections for atomic number and plotted error histograms for each based on 229 analyses. Based on these data, the moit successful atomic number cor- rections were that of Thomas and that of Duncumb and Reed (197) d2scribed above. Another error histogram plot- ted by Duncumb and Reed s h o w clearly the improvement in agreement between known and calculated com- position using the fitted value of J in the calculation of the stopping powerh. Belk (51) proposed a simplified correc- tion for atomic number which can be applied to a great percentage of micro- analyses. Csing an error histogram, the results on 150 analyses using the simplified method were comparable to the results obtained with more com- plicated correction procedures.

Theisen (629-691) in his proposed correction procedure has included a part of the atomic number effect;

namely, the energy loss due to back- scattering. Because no correction is made at the same time for stopping power and the R and S factors act in opposite directions to partially offset each other, application of a correction for backscattering alone would not appear to be successful. Indeed the comparison by Poole (,510) confirms this view.

illthough in general the atomic number effect can only be evaluated by statis- tical means, in some samples the absorp- tion and fluorescence corrections are sufficiently small that any difference between measured and calculated com- position will be the result of the atomic number effect. Such samples are not common. One interesting case, how- ever, is the copper-nickel system. Although adjacent elements in the Periodic Table are involved, a small but significant atomic number effect is expected because the Z I A ratios of copper and nickel are considerably different. Ranzetta and Scott (61 7 ) were able to show the existence of the atomic number effect for the analysis of copper in copper-nickel alloys because the absorption coefficients for the C u K a line are small and almost equal. The small contribution of fluorescence by the CuKP line to the XiKO intensity weakens the evidence for an atomic number correction in the analysis of nickel in these alloys.

Computer Techniques. Computers are used in two main areas of applica- tion for electron probe microanalysis. On the one hand, high-speed com- puters are needed for the solution of the complicated equations relating the interactions of electrons with matter t o X-ray production. On the other hand, computers are being used simply as a labor-saving device in the less-complicated equations used to re- late measured X-ray intensities to composition.

Bishop (67, 68) used Monte Carlo techniques to follow trajectories for a large number of electrons. The paths of the electrons were divided into 25 equal steps. The scattering in each step waq calculated from inelastic and elastic scattering laws. Except for carbon the backscatter coefficients a t 30 kT' calculated by Bishop are 8% greater than measured values. I t is interesting that this 8% difference could be removed by adjusting the J factor in Bethe's equation for energy loss, similar to the adjustment re- quired by Duncumb and DaCasa (194) to improve the agreement of the atomic number correction. =it 10 kV, an increase in the backscatter coefficient is predicted, although for large Z the backscatter coefficient actually de- creases with decreasing electron volt- age. Bishop believes that these dis- crepancies could be removed by better

VOL 40, NO. 5, APRIL 1968 363 R

Page 19: X-ray absorption and emission

approximations to the scattering pro- cess. 6 ( p a ) and f ( ~ ) curves calculated by Monte Carlo technique show similar differences.

D. B. Brown and Ogilvie (93, 94, 484) described an electron transport equation that is used to predict the dis- tribution of depth of X-ray production, 6 ( p z ) , the absorption correction, f ( x ) , and the energy distribution of back- scattered electrons. The values pre- dicted by this approach are in good agreement with the experimental curves for 6 ( p a ) and f ( x ) as well as for the backscatter coefficients. The predicted distribution of the energies of back- scattered electrons, however, does differ somewhat from measured distributions. This type of calculation has reached the point where improvements in the model cannot be evaluated because the im- provements lead to differences in the predicted values which are of the same order of magnitude as the errors in the measurement of the values. More accurate measurements of such prop- erties as 6 (pz), f ( x ) , and backscatter coefficients are required so that con- tinued improvements of this model can be made.

It is impractical a t the moment to use the Monte Carlo method of transport equation for routine quantitative anal- ysis because of prohibitive calculation times. At the same time these theo- retical approaches are very important in testing the simplified equations actu- ally used for quantitative analysis. These simplified equations have been programmed to relieve the analyst from the chore of the iterative calculations required to relate X-ray intensities to composition. One of the important considerations in any such program is the convergence of the iterative proce- dure. Reed and Mason (525) have proposed an iteration procedure which they claim will have a much larger prob- ability of convergence than other tech- niques which have been used. In sev- eral hundred analyses for which a pro- gram written by Brown (95) has been used, less than 10 have failed to con- verge within the limit of 20 iterations set in the program using simple but small convergence limits.

The program of Brown (95) is quite general for calculating composition from measured X-ray intensities. Either pure elements or compounds may be used as standards. Corrections for dead time and background are applied to the measured intensities. Several different absorption, fluorescence, and atomic number corrections are pro- grammed which can be selected by code number.

Frazer, Fitzgerald, and Reid (247) have published a program which has only a single absorption and fluorescence correction. The strength of this pro- gram lies in its very versatile data input

requirements and the extensive choice of output format. Beaman (44) has also developed a program in which mass absorption coefficients, jump ratios, fluorescent yields, and atomic number parameters are internal to the program.

Hobby and Wood (319) have pro- grammed absorption and fluorescence corrections. Hanneman and Lifshin (286) use computer-generated theo- retical curves, fitted to the Ziebold- Ogilvie linear relation for quantitative analysis. Their program can also gen- erate diffusion coefficients from the cal- culated compositions for data from diffusion couples. Similarly, Hoff and Gregory (323) include in their program the ability to calculate diffusion co- efficients.

A number of evaluations of correction procedures refer to computer programs (43, 154, 307, 510), and indeed the only practical method of handling the large amount of data required for significant evaluations of the atomic number effect is by computer. R e must not forget, however, that all the errors of mass ab- sorption coefficients, etc., are not over- come by some magical property of the computer. The results printed in neat rows by a high-speed printer must be subject to the same scrutiny and skep- ticism as any hand-calculated results.

Instrumentation and Sample Tech- niques. Several new instruments have been developed by the manufacturers of electron probe microanalyzers dur- ing the past two years. All of these represent second- or third-genera- tion microanalyzers which will do the same analyses as the earlier instru- ments but are easier t o operate and more stable. The number of acces- sories available for the various instru- ments is increasing. dl l have soft X-ray spectrometers and beam scanning with a variety of signals, and most have Kossel cameras. Sorton (483) has outlined some of the characteristics necessary for a research microanalyzer to be used for a wide variety of prob- lems. S o t all of these characteristics can be found in every instrument.

One of the interesting developments over the past five or six years has been the combination of an electron micro- probe and electron microscope in a single instrument. W. C. Nixon and P. Duncumb in England have been pio- neers in this kind of instrument in which an electron micrograph of quite good resolution can be obtained at the same time as compositional information from the X-rays generated in the sample. Two commercial manufacturers (156, 556) are now marketing combination instruments which have been developed by adding projection lenses to an elec- tron microprobe. In Russia, Vasichev (648, 649) has built a combination in- strument which has two semifocusing spectrometers. The electron column

of this instrument is described in another paper (650), and techniques for aligning the column are reported (595). The opposite approach has also been taken. Starting with an electron microscope, X-ray detection systems have been added to give the combination instru- ment. Fuchs (252, 253) has attached a semifocusing spectrometer to a Siemens electron microscope. A nondispersive system was attached to a similar micro- scope by Giraud-Heraud, Sifferlen, and Saulnier (261). Using a flow propor- tional counter, elements having a differ- ence of atomic number of a t least 2 in the region of copper in the periodic table could be separated. Koffman, Schippert, Moll, and Hamill (392) have developed a spectrometer attachment for a Philips EM-200 electron micro- scope which uses a mica crystal whose bending radius is varied for focusing. These instruments permit the direct correlation of composition with a magni- fied image, but thin samples are re- quired for the transmission electron micrographs. To examine bulk speci- mens by electron microscopy and micro- analysis, Estill and Robertson (213) have used the contamination layer formed during analysis in an electron probe microanalyzer as a replica for subsequent examination in an electron microscope, thus achieving the often difficult task of relating data from both techniques to the same area of sample.

An interesting new electron probe microanalyzer, which incorporates a mini-lens as the objective lens, has been developed by -4. B. Bok, L. A. Fontijn, and J. B. LePoole a t the Technisch Physische Dienst, T.S.O. Delft, Hol- land. The intriguing feature of this instrument is the small size of the elec- tron optical column, leaving a great deal of space available in the vicinity of the sample. The mini-lens used as the objective lens of the electron column is only 50 mm high and 46 mm in diameter. The electron beam diameter a t the sample surface is less than 1 micron. Because of its small size and the equally small bore, the optical microscope cannot be placed concentrically with the electron optical column. Instead the electron column is tilted a t 45 degrees to the sample surface so that a standard optical microscope outside the vacuum system can be used to look directly down on the sample through a window above the sample. Two spec- trometers having 30 degree take-off angles are placed on opposite sides of the sample. Because of the small size of the objective lens, X-ray take-off angles of up to 60 degrees are possible with the optical microscope in position, and one spectrometer with a take-off angle of 90 degrees would be feasible if the optical microscope were removed.

Beam scanning is an important tech- nique for qualitative analysis. The

364 R ANALYTICAL CHEMISTRY

Page 20: X-ray absorption and emission

signals nhich can be displayed are al- niost limitless (299). Kimoto et al. (376), by using electron detectors sym- metrically located on either side of the sample, removed contributions due to surface irregularities from beam scan- ning pictures. Scanning techniques have been applied to quantitative in- clusion counting. Melford and JT7hitt- ington (448) and Dorfler et al. (188-190) have developed auxiliary instrumenta- tion for determining the number, size, and approximate composition of inclu- sions in the area scanned. Melford and Whittington combine data from two X-ray spectrometers and backscattered electron current, using logic circuits to recognize a maximum of three types of inclusions. The size of the inclusions is determined by using clock signals which are gated on and off with the appearance of X-ray signals related to a given type of inclusion. Dorfler et al. are develop- ing a similar system except they propose to record the data for later analysis by computer. Any microprobe inclusion counter should have the advantage over optical systems, of determining in- clusion type on the basis of composition.

To improve the information con- veyed by beam scanning pictures, a number of techniques have been used for displaying data. Wittry and Van- cowering (680) described a system for stereoscopic display using, as an ex- ample, cathodoluminescence from G a l s . An isometric display is formed by using the rasters which drive the beam scan- ning to drive the 5 and y axes of the oscilloscope. XOK, however, a small component of the y (slowly varying) raster is applied to the z deflection and the signal, instead of modulating the intensity of the oscilloscope trace, is added to the y deflection. Stereoscopic pairs of images can be obtained by in- creasing the contribution of the y raster to the T deflection to vary the angle between the z and y coordinates of the display. Dorsey (192) used a simi- lar technique, but with a single display, to demonstrate the existence of an effect of magnetic fields in a sample on back- scattered electron intensities. Hein- rich (299) has stored data in a multi- channel analyzer memory, then used a similar display technique for readout of data .

Heinrich (299) first described a tech- nique for placing limits on the signal displayed on the oscilloscope screens, calling the technique concentration mapping. Christian and Schaaber (149) have developed a similar instrumenta- tion for a Cambridge microanalyzer. They have applied the techniques to studies of surface engraved pictures (147, 148).

Resolution of beam-scanning pictures is directly related to the electron beam diameter when electron images are re- corded and indirectly related through

the volume in which X-rays are gen- erated when X-ray images are recorded. Beam diameters have been measured from the shape of the profile of the sam- ple current os. distance in crossing a discontinuity in the sample or from the size of the contamination spot formed on a sample. The size of the contamina- tion spot is consistently larger than the beam diameter determined by travers- ing a discontinuity (24). Hehenkamp (897) described a sample composed of alternate copper and gold layers on a copper block which was sectioned and polished to reveal the edges of the lay- ers. This sample can be used to de- termine the effective electron beam diameter by noting the minimum thick- ness of layer which will give the same intensity as the bulk specimen. h simi- lar sample of Cu-Si layers has been de- scribed by Belk and Clayton (52). Rapperport (622) has used a decon- volution technique to increase the res- olution of electron probe microanalysis beyond what would be expected on the basis of the electron beam diameter.

Abelmann and Jones (4) have in- vestigated the effects of X-ray take-off angle and electron incidence angle on peak to background ratios and the ap- plicability of the correction equations. They found that after removing the effect of back-scattered electrons. the beak to background ratio was almost in- dependent of X-ray take-off angle. The electron incidence angle is more of a problem because no simple relation was found for relating the absorption equa- tion used for normal electron incidence to non-normal incidence.

Several sample stages have been de- scribed for heating microprobe speci- mens during analysis for studies of (om- positional changes a t elevated tem- peratures. Kimoto, Hashimoto, and Tada (377) describe a stage using a porcelain crucible which can be used a t temperatures up to 110' C. Miller and Wittry (458) developed a sample stage in nhich the temperature can be controlled to +4' over a temperature range of 100 to 500' K. This stage would permit the analysis of materials that are sensitive to heating by the elec- tron beam, such as gallium metal.

The flow proportional counter con- tinues to be the most suitable detector for electron probe microanalysis, par- ticularly in the long-wavelength region. A design of a typical counter can be found in the paper by Braybrook et al. (88). The major difficulty with the flow detector is the now well-docu- mented decrease in pulse amplitude with increasing counting rate (42, 104, 603). Spielberg (603) found that the im- portant factors in the pulse shifts were the size and cleanliness of the anode wire and the gas gain in the detector. By increasing the diameter of the anode wire to 125 microns, no shifts were ob-

served for counting rates up to ap- proximately 10,000 counts per second, whereas with very small anode wires significant shifts can be detected for counting rates as low as 500 counts per second. Beaman ( 4 Z ) has found de- creases of up to 25% from the true in- tensity ratio because of pulse amplitude shifts when using a pulse height analyzer with a rather narrow window. Errors can be avoided by using wider windows, changing the gain in the amplifier, or decreasing the base line in the pulse height analyzer.

Heinrich, Veith, and Yakowitz (304) have studied methods of correcting for dead time in the detection system. They found that the best equation for dead time correction is

where NT and No are the actual ob- served counting rates and t is the dead time of the total counting circuits. Several methods of determining dead time are evaluated in their paper.

Multichannel analyzers are finding increased use for data storage and dis- play from analyses of large numbers of sample points. Heinrich (299) gives several examples of application to con- centration mapping. Fergason (296) has used a multichannel analyzer for storage of data along linear traverses. Background is corrected automatically by rescanning along the same line with the angle of the spectrometer appropri- ately adjusted. A method for de- termining extremely low concentrations of elements also utilizes a multichannel analyzer (226). The electron beam is caused to jump back and forth between two areas of a sample, one of which may be a standard. The data from the two areas are stored in different quadrants of the memory of a 400-channel analyzer. Concentrations of Al, Si, Ni, and Fe in U have been determined a t the 100-ppm level with precisions of i. 10 ppm 2a using this technique.

The analysis of radioactive specimens requires special techniques-both in the protection of the operator and in the preparation of the sample to avoid con- tamination of the instrument. Scotti, Johnson, and Cunningham (562) de- scribe modifications to a microprobe for handling hot samples. The modifica- tions consist for the most part in the provision for additional radiation shield- ing. Padden, I h r t o n , and Campbell (493) circumvent the shielding prob- lems by using very small samples. Hudgens and Roesch (337) describe techniques to contain the activity of alpha active specimens. thus avoiding contamination of their electron micro- probe.

Sample preparation is probably the single most important step in electron

VOL. 40, NO. 5, APRIL 1968 365 R

Page 21: X-ray absorption and emission

probe microanalysis and is doubly im- portant in the case of standards to be used in evaluations of quantitative analysis. These must be homogeneous and of accurately known composition. Goldstein, Xajeske, and Yakowitz (264, 265) have used a splat cooling technique for preparation of standards. .A molten alloy is dropped onto a cooled copper plate, where it cools instantly and solidifies. Because of the rapid cooling, segregation is prevented. They report that standards can be prepared in which the variation between pieces and within pieces closely approximates the ex- pected standard deviation owing to counting statistics alone. Standards prepared in this way are not neces- sarily stable and may segregate with time. The composition of the stand- ard should be determined chemically, because it can vary significantly from that espected on the basis of the weight of the elements mixed together in forming the alloy.

Yakowitz et al. (689) have continued the evaluation of present Sational Bureau of Standards standard samples for possible use as electron microprobe standards. Cartridge brass standards were found to be quite homogeneous and very suitable as microprobe standards; low-alloy steels on the other hand show segregation of some of the minor ele- ments. Thus, the steel samples can be used as standards for some elements which form homogeneous solid solutions with the iron matrix, but not for others which are found localized in inclusions.

Walter (660) deqcribed a method of preparing silicate standards using an aqueous silica gel solution which is sprayed onto a heated platinum foil to produce a homogeneous powder. Ele- ments such as A I , Mg, Ca, K, Xa, and Fe are added to the solution a'. nitrates. The powder is pressed into a dense translucent pellet whose surface is quite suitable for analysis. Some varia- tion (up to about 7% using a submicron electron beam) was found in the stand- ards, indicating some inhomogeneity is still present. J. V. Smith (687) de- scribed a method of mounting mineral standards by placing the mineral grains in holes drilled into 1-inch-diameter brass cylinders. Epoxy resin was then carefully poured over the grains and allowed to harden. Polishing wa5 achieved using paper or copper laps, but if cloth laps were used, especially with an excess of lubricant, considerable relief resulted. Smith also described a method of preparing thin sections suit- able for microprobe analysis. Hooper (336) studied various embedding com- pounds suitable for preparing samples of foraminifera. He desired an embedding medium which is transparent, stable under the electron beam, and of hardness 3 on the Moh's scale. Styrene was found to satisfy these requirements, al-

though the embedding procedure re- quired several days to complete.

Silicate glasses have been found to be unstable under bombardment with the electron beam. The sodium or potas- sium intensity usually decreases with time of bombardment with the electron beam ('79, 647), although both Borom and Hanneman ('79) and Fredriksson (251) found samples in which the S a K a intensity increased by a factor of three. A mechanism for this increase in X a concentration has been suggested ('79). Xoving the sample during analy- sis can help to reduce these changes in X-ray intensity, but stable and mean- ingful intensity readings are not ob- tained.

A symposium on sample preparation was held a t the First National Con- ference on Electron Probe Microanaly- sis with major papers on geological, biological, and metallurgical specimen preparation. Pickleseimer and Haller- man a t that symposium quantitatively assessed the effects of sample roughness by measuring the intensity across thin copper grids mounted on copper blocks. They found that a ridge of only 1 or 2 microns can significantly affect the measured X-ray intensities, while steps of 4 and 12 microns can reduce the meas- ured X-ray intensity by 5070 for take- off angles of 15.5' and 35', respectively. Pickleseimer and Hallerman also ex- amined the problem of smearing soft phases over ha,rder ones during polish- ing. Layers of pure element less than one atomic layer thick, spread over one another, could be detected. Etching was recommended to remove any smeared material in any samples where smearing was suspected. Many of the techniques with regard to biological samples which Tousimis described at the symposium were published in a review article (634). Low-Energy X-Rays. The fact

that every electron microprobe manu- facturer has available a spectrometer for measuring the intensity of low- energy X-rays has spurred interest in analysis using these wavelengths. Three methods are used in the separa- tion and detection of these wave- lengths. Crystals made up of layers of soap molecules are used as the dis- persing element of the most common type of curved crystal spectrometers presently used (f34.4, 369, 619). In- terest has also been shown in the use of gratings a t grazing incidence for separating wavelengths (88, 416). The intensities obtained by the two typey of spectrometers appear to be comparable, but the soap crystals are more com- monly used because they are somewhat easier to produce. The third method of wavelength separation utilizes the fact that the output pulses from a propor- tional detector are proportional to the energy of the incident X-rays. Cooke

and Duncumb (157) and Wardell (661) use an electronic system to select nar- row output voltage ranges character- istic of up to three element.. The in- tensity related to each element is de- termined by solving three simultaneous equations, again using electronic cir- cuitry. Cooke and Duncumb point out the advantages of the nondispersive system when low intensities are en- countered. Kimoto and Hert (378) have compared the use of dispersive and nondispersive techniques for low atomic number elements. Castaing and Pi- choir (134) described a nondispersive system for analysis using low-energy X-rays in which a Ross filter technique is used. The filters are gases which are contained in gas cells. The method was applied to the detection of oxygen Ka radiation. A linear curve was ob- tained for intensity of oxygen K a us. concentration for 7 oxide samples for oxygen concentrations of less than 10 up to more than 50 weight per cent.

Although detection of low-energy X - rays has become almost routine, the problems of quantitative analysis are quite formidable. Some of these prob- lems have been reviewed by Henke ( S l l ) , ilrrhenius (66), Koffman, 11011, and Norton (391) and Scott (561). Many authors have measured the shifts in wavelengths due to chemical binding. .A review of recent measurements can be found in the X-ray section of this paper: The changing shape of the emission lines iy also a problem, and it has not been settled whether peak in- tensities or integrated intensities over the entire line should be uqed in the quantitative equations. I n additional problem has been pointed out by Haun and Fischer (40). Self-absorlbtion of emission bands in the 10 to 50 A wave- length region can alter significantly the shape of emission bands a3 a function of electron voltage (see Figure 2). With such problem<, any relation between X-ray intensity and concentration will be difficult to find.

Coupled with these fundamental problems of relating X-ray inten4ties to concentration are more practical ones of knowing what value' for mass ab- sorption coefficients or fluorescent yield should be used. Table? of Henke et al. (312) are the only compreheii4ve tables of mass absorption coefficients avail- able for wavelengths longer than 10 .&. Singer (583) has recently measured the mass absorption coefficient for alumi- num a t the carbon K wavelength and has found values of 36,000 to 43,000, approsimately 25% higher than the value of 30,000 found in Henke's tables (312). Openshaw, Pearce, and Jeffery (489)) on the other hand, in analyzing uranium and silicon carbide. found that a mass absorption coefficient of about 2200 was required for abyorption of the CK line by uranium to explain the varia-

366 R ANALYTICAL CHEMISTRY

Page 22: X-ray absorption and emission

tion in observed intensity as a function of electron voltage. This value is about a factor of five lower than published values. Since f(x) curves for carbon in silicon carbide [Duncumb and Mel- ford (196)] were used for the absorption correction, any large differences be- tween measured and known concentra- tions should be due to parameters used in the equations rather than the models, unless, as is postulated by Openshaw, Pearce, and Jeffery, a significant fluo- rescence of carbon K a radiation by uranium S radiation occurs. So meth- ods are presently available for even an order of magnitude estimation of such a fluorescence effect.

The Philibert equation as modified by Duncumb and Shields becomes less satisfactory as a method for the ab- sorption correction as the mass absorp- tion coefficients become larger, that is, as the analytical wavelength becomes longer (305). Several authors (17, 307, 587) have commented on the lack of agreement of the absorption correction for long wavelengths even when the modification of Duncumb and Shields is used, a modification which was de- signed to improve agreement a t low elec- tron voltages and long wavelengths.

For the very long wavelengths, the mass absorption coefficient becomes larger than the electron absorption co- efficient, and Duncumb and Melford (196, 196) have proposed a thin film model. I n this region, the intensity of X-rays measured by the detec- tor tends towards ~ ( 0 ) A(pz) , where +(O) is the ionization and A(pz) is the effective thickness of the emitting layer which is inversely proportional to X . For samples and analyzing conditions where the thin film model applies, the measured relative intensity kA' is related to concentration by the expression

Values for the surface ionization +(O) are obtained when + ( p z ) curves are measured by the sandwich sample tech- niques (96, 136, 575, 654). Hutchins and Wantman (341) described an alter- nate method of measuring + ( O ) by ex- trapolating a plot of X-ray intensities from thin films deposited on substrates of varying atomic number to atomic number 0. They claim that +(O) de- termined by the isolated film technique is subject to errors due to buckling of the film resulting in values which are too low. However comparison of +(O) values by the two methods indicates that the extrapolation methods yielded values which are slightly lower than the iso- lated film method. A thorough evalua- tion of the proposed thin film model has yet to be made.

A technical problem in analysis using low-energy X-rays is the formation of a

contamination layer due t o breakdown of the hydrocarbon gases present in the vacuum system. This layer is useful in Jhe wavelength region shorter than 5 A because it serves as a marker to identify areas which have been analyzed and has no significant effect on the measured X-ray intensities. Such is not the case for the longer wavelengths. When analyzing for carbon using the CKa line, a gradual increase in intensity is observed because of the signal from the carbon in the contamination layer (196, 387, 488, 518, 521). For analyses using the O K a or N K a lines, the in- tensity may decrease with time be- cause of absorption in the carbon layer. Techniques for reducing the contamina- tion layer usually involve a cold finger near the sample, although Duncumb and Melford (196) found that a finely focussed beam tended to form a ring contamination spot which did not in- terfere with analyses using low-energy X-rays. This may not be true for all types of samples.

Despite the problems of quantitative analysis using low-energy X-rays, op- timism is not entirely misplaced. For wavelengths shorter than the K line of sodium, the equations quoted in the section of quantitative analysis can be used with accuracies of *lo% of the amount present assured and +5% probable. For longer wavelengths, the thin-film method of Duncumb and Melford (196) perhaps can be used, but verification of this model must await a more thorough evaluation. Calibra- tion curves such as those by Ong (488) and Weinryb and Hourlier (667) for carbon in steels using the C K a line suggest that true quantitative analysis will be possible in selected systems where calibration standards can be made. The many examples of successful ap- plication of qualitative microanalysis using low-energy X-rays (365, 366, 539, 667) can serve only to accelerate interest in more quantitative results. Reliable quantitative analysis for samples using pure elements as standards and low- energy X-rays as analytical wavelengths is still far from a reality but continued significant progress can be expected.

Auxiliary Techniques. I n addition t o the generation of characteristic X-rays, a number of other electron- sample interactions can be used t o gather information on t h e composi- tion or structure of a sample (427, 668). I n recognition of this fact, the manu- facturers of electron microprobes have made available a variety of detectors or accessories to utilize signals dependent on these interactions. The signals may be sample current or backscatter current related to inelastic or elastic electron scattering, photomultipliers to detect cathodoluminescence, or a Kossel cam- era to take advantage of microdiffrac- tion.

Sample current has been used as an alternate method of measuring composi- tion of binary samples. However, the sample current in an electron micro- probe is very sensitive to the number of secondary electrons leaving the sample and hence to any bias applied to the sample (155, 303, 678). A large in- crease in sample current is observed in changing the bias on the sample from 10 volts negative to 10 volts positive. Quantitative analysis is possible using a positive bias on the sample, the observed sample current being a linear function of composition between the limits of the two pure element end members (155, 303). The results of analysis by back- scattered electrons are best for voltages of 30 kV and above, presumably be- cause of the greater importance of sur- face effects a t lower voltages. Xalissa and Triebel (429) have studied the im- portance of surface condition on the number of backscattered electrons. I n nonconductors, sample current meas- urements should be treated with caution because of the possibility of local charg- ing within the specimen.

The detection of low-energy electrons emitted by the specimen is being used with beam scanning to produce a magni- fied image of the specimen with tre- mendous depth of focus (299). With such a detection system, the electron microprobe becomes a scanning electron microscope which has application in the study of the structure of rough surfaces such as fractures. Watanabe (663) used the energy loss spectrum as a means of identifying elements of low atomic number.

The production of visible, infrared, or ultraviolet light on interaction with electrons (cathodoluminescence) is an- other sample characteristic that has been utilized in analysis. Davey (173) has described an optical spectrometer which has been attached through the optical microscope to an electron microprobe for analysis of the cathodoluminescence radiation. Large differences are noted in the images obtained for orange and blue light emission which are not ap- parent in the total cathodoluminescence image even if recorded on color photo- graphic film. Smith and Stenstrom (591) have used a 35-mm camera at- tached to the optical microscope eye- piece to obtain some striking color photographs of cathodoluminescence of minerals. The size of the electron beam was enlarged so that an area more than 100 microns across is recorded on the film.

The Kossel technique of microdiffrac- tion has also been the subject of many papers during the past two years. Vieth and Yakowitz (652) listed several requirements for a Kossel camera and described a camera that meets these criteria. Openshaw and Swindells (490) have developed a Kossel camera that

VOL. 40, NO. 5, APRIL 1968 367 R

Page 23: X-ray absorption and emission

can be used for both reflection and transmission. This camera takes the place of the normal sample stage in an AEI microanalyzer. Vieth and Yako- witz also described a simplified electron column with one lens which can be used with a Kossel camera as an inexpensive instrument for microdiffraction (661). Yakowitz and Vieth (688) have de- veloped an expression which can be used to relate the necessary exposure times for Kossel patterns. Yakowitz (687) has also investigated the allied problem of the effect of sample thickness and electron voltage on contrast. Ullrich (642) has measured lattice parameters of a number of substances using the back reflection Kossel method. The exposure times required in his apparatus were less than 10 minutes.

The interpretation of Kossel patterns has now progressed beyond cubic pat- terns. Morris (466) and Frazer and Reid (248) both have developed com- puter programs to aid in the calculation of lattice parameters from lens inter- sections for noncubic patterns. Frazer and Arrhenius (646) have written a computer program for generating both absorption and diffraction conics for various crystal systems. The distinc- tive feature of the Kossel patterns is the intersection of three or more conics which can be used as an aid in interpret- ing the patterns. MacKay (423) de- scribes the use of the reciprocal lattice in the interpretation of lattice param- eters. He has also evaluated sources of errors in Kossel patterns (422) and points out that earlier measurements of the nickel lattice parameter by the Kossel technique were in error, pre- sumably because of heating by the electron beam.

Because the Kossel technique can be used for precise lattice parameter de- terminations, stresses or strains modify the patterns quite markedly. Umeno, Kawabe, and Shinoda (644, 645) have studied the plastic deformation of alumi- num using the back reflection Kossel patterns and were able to show that distortion of the lattice near a grain boundary is greater than the distortion away from it. Umeno, Gennai, and Shinoda (643) have studied plastic de- formation in aluminum and zinc and found that distortions in planes parallel to grain boundaries are greater than in those perpendicular to the grain bounda- ries. The Kossel technique can thus be used to provide significant metallurgi- cal information as well as the crystal- lographic data of precise lattice param- eters.

Applications. Table IX indicates some of the fields of applications of electron probe microanalysis. Cer- tainly the most prolific area of applica- tion is in metallurgy, particularly in the identification of inclusions and in diffusion studies. J. D. Brown

reviewed recent applications a t the ASTM annual meeting in Atlantic City, June 1966 ( 1 4 , and K. F. J. Hein- rich reviewed qualitative applications in a discussion of beam scanning tech- niques a t the same meeting. A repre- sentative sampling of papers on applica- tions can be found in the proceedings of the Paris meeting (131).

An interesting aspect of many applica- tions is the combining of information from a number of techniques to solve problems which could not be solved by an electron microprobe alone. One aspect of this is the combination of the electron microscope with an electron probe microanalyzer in a single instru- ment. Schippert, illoll, and Ogilvie (556) have described applications of one such instrument to analysis of fine par- ticles and precipitates as well as bio- logical tissues. White (668) has used both electron microscopy and micro- probe analysis on the same sample, but with the necessity of transferring the specimen from one instrument to the other to complete both analyses. The advantage of a single instrument is clearly apparent when the difficulties of finding the same area of a specimen in two separate instruments are con- sidered.

Electron diffraction has also been used to complement compositional data obtained in an electron microprobe. Estill, Robertson, and Conrad (614) used extraction replicas to remove in- clusions, which were then analyzed by electron diffraction and electron probe microanalysis. By separating the in- clusions from the matrix, the effect of the matrix on the probe results could be minimized. Helgesson (308) has com- bined results from X-ray diffraction and electron probe microanalysis to unravel the mechanism of bonding of ceramic to metal seals.

An entirely new and unique applica- tion of the electron probe microanalyzer was described by Dorsey (192). If two electron detectors are placed sym- metrically on either side of the sample to detect secondary electrons from the sample and the sample is flat and uni- form in composition, then any differ- ence in the intensity of electrons reach- ing the two detectors will be due to the magnetic field in the material. Dorsey used this technique to detect magnetic fields of less than 100 gauss in thin-film magnetic tape.

A favorite technique for the analysis of meteorites continues to be the elec- tron microprobe. This instrument has been used for the analysis of relatively low concentrations of elements in metallic meteorites (269), variations in concentrations resulting from the slow cooling of meteorites (268), and the identification of entirely new minerals (254, 364-367). A particularly in- teresting example of this latter applica-

tion was the discovery of a mineral, subsequently named sinoite; beam scan- ning pictures for O K a and N K a were a significant factor in the discovery (365, 366). Quantitative microanalyses were performed on this mineral, with rather remarkable precision for nitro- gen and oxygen concentrations (365).

The thickness of very thin films which are less than infinite thickness with re- gard to absorption of the electron beam can be determined in an electron probe microanalyzer. The intensity will in- crease as a function of thickness until the electrons are all stopped within the thin film. The shape of the intensity vs. thickness curve is directly related t o the + ( p z ) curves previously described. The values for +(O) which Hutchins and Wantman (341) have determined are crucial to accurate film thickness deter- minations. For alloy films, Whittle and Wood (671) have developed a method for determining composition as well as thickness. Composition determina- tions are accurate to 10% of the amount present. Philibert and Penot (501) have studied resolution as a func- tion of depth in an electron microprobe, a problem related to the determination of film thickness. The maximum thick- ness which could be determined was a strong function of the overvoltages. Films as thin as 500 a of Fe20a on iron could be identified by lowering the electron voltage sufficiently. Similarly an enhancement in chromium concen- tration of 4 to 6% in a heat-treated stainless steel could be detected with an electron accelerating voltage of 6.25 kV but not a t 10 kV or higher. This would indicate that the thickness of the enriched layer was only a few hundred Angstroms.

C. R. Hall (682) has measured the intensity generated in thin single crys- tals as a function of direction in the crystal. He found that the generated intensity varied strongly with direction in the crystal, the differences being as large as a factor of two for very thin crystals (<lo00 A). As the crystals become thicker, the variations de- crease. For bulk samples, Hall does not believe that any directional effect of X-ray production is significant. However, for thin single crystal films or small precipitates, the measured inten- sity may vary with crystallographic orientation.

The electron probe microanalyzer has yet to reach its full promise in applica- tion to biological problems. The most prevalent use is the determination of concentrations of heavy elements in tissues (284, 347, 634) or the analysis of calcium-phosphorus ratios in teeth or bone (320, 321). One interesting ap- plication was the detection of tin in the enamel of teeth resulting from the use of stannous fluoride for decay preven- tion (322).

368 R ANALYTICAL CHEMISTRY

Page 24: X-ray absorption and emission

T. Hall (283) has pointed out some of the difficulties and problems that are limiting the promise of electron probe microanalysis in applications to biology and medicine. Biological samples con- sist of tissues that contain large con- centrations of water. This water is removed in preparation for analysis in the electron microprobe. Because of this, concentrations in weight per cent have little meaning for the biologist and all of the quantitative analytical methods break down when dealing with biological samples. What is required is some technique for determining volume concentrations with an accuracy of 10% of the amount present in the dried tissues. Hall (888s) and Marshall and Hall (486) have proposed a technique in which characteristic line intensities are compared to the intensity of the continuum. Very significant progress could be made in the application of the electron probe microanalyzer t o biologi- cal problems if experts in the field of X-ray generation could be interested in the unique problems of quantitative analysis of biological samples. Perhaps the National Meetings which bring to- gether probe users in all fields of ap- plication will foster this cross-fertiliza- tion of interests.

LITERATURE CITED

( 1 ) Aaronson, H. I., Domian, H. A., Trans. Met. SOC. AIME, 236,781 (1966).

(2) Ab, E., Andrianova, G. M., Plotnikov, P. I., Khutsishvili, L. A., Questions of Mining Geophysics, 4, 130 (1964); Eng. Translation avail. from Clearing- house for Federal and Scientific In- formation, Springfield, Va.

(3) Abdel Gawad, A. M., Am. Miner- alogist, 51,464 (1966).

(4) Abelmann, R. A., Jones, R., J . Appl. Phys., 37,4507 (1966).

(5) Adler, I., “X-Ray Emission Spec- trography in Geology,” Elsevier, Xew York, 1966,258 pp.

(6) Adler, I., Goldstein, J., Natl. Aera . Space Admin., NASA-TN-D-2984 (i965).

(7) Adler, I., Goldstein, J., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 210.

(8) Adler, I., Rose, H. J., Jr., “Trace Analysis Physical Methods,” G. H. Morrison, Ed., Wiley, New York, 1965, p 271.

(9) Adler, I., Trombka, J., ORNLIIC- 10,929 (,1967).

(10) Afonin, V. P., Pavlinskii, G. V., Zavodsk. Lab., 32, 1343 (1966) (Eng. ed.).

(11) Aleksiev, E., Boyadjieva, R., Geo- chim. Acta, 30,511 (1966).

(12) Alexander, G. V., ANAL. CHEM., 37,1671 (1965).

(13) Alley, B. J., Myers, R. H., Ibid., p 1685.

(14) Amer. SOC. Testing Mater., “Fifty Years of Progress in Metallographic Techniques,” Spec. Tech. Publ. 430 (1967).

(lij-Amicarelli, V., Sersale, R., Rebuffat,

(16) Andermann, G., ANAL. CHEM., 38,

(17) Andersen, C. A,, Brit. J . Appl.

P., Ric. Sci., 36,980 (1966).

82 (1966).

Phys., 18,1033 (1967).

Table IX. Biological

General Plants Soft tissues Teeth and bone

Bonding layers Ceramics Corrosion products Diffusion Ferrites Metallurgical

Aluminum Cast iron Inclusions Phase diagrams Slags Steels

General

Inclusions Phases Wear Welding

Mineralogical General Cement Glasses Iron ores Marine deposits Meteorites

Metallic Nonmetallic

Oxides Silicates and silicides

Sulfides Nuclear materials Oxidation Semiconductors Surfaces

Applications of Electron Probe Microanalysis

(19, 634) (404 ) (256, 281, 284, 381, 545, 693) (249, 320, 322, 649) (224, 308) (87, 599) (99 1 ‘c;;g@90f49, 485)

(62, 609, 676) (353, 461, 541) (511 ) (135, 150, 267, 407, 414,486,548,555) (359)

(66, 156, 215, 892, 349, 396, 406, 459, 460, 476, 496, 677,

(56, 78, 100, 373, 374, 502, 540, 573)

( 4 ~ 1 , 5 1 1 )

619, 636)

(1, 50, 71, 72, 866, 315, 334, 389, 408, 462, 603, 6.90)

(812, 488)

(5,329,560) (600, 627) (79, 80, 251, 641) (16, 75, 185, 445) (76, 106, 332, 557)

(268, 969, 487)

(63, 333, 485, 685)

(698, 675, 684)

(151, 187, 254, 268, 365-367, s98,494,52r)

(63, 81, 159, 923, 242, 335, 336, 364, 399, 416, 587, 588- 590, 662)

(84, 191, 352, 519, 555, 613, 617) (1 79, 2449, S93, 460, 61 3 )

(137, 538) (101, 442)

(18) Andersen, C. A,, Chemistry, 40, 16 (1967).

(19) Andersen, C. A,, Hasler, M. F., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 310.

(20) Anderson, A. T., ANAL. CHEM., 39(2), 138A (1967).

(21) Ansell, K. H., Stevenson, J., ORNG

(22) Anspaugh, L. R:, Gofman, J. W., Lowe, 0. A., Martin, W. H., ORNL-

(23) Aoki, K., Sawatani, T., Yawata Tech. Rept. 254,6494 (1966).

(24) Arlt, H. H., Mikrochim. Acta, Suppl. 1,242 (1966).

(25) Ark, H. H., Bloch, R., Mikrochim. Acta, 447 (1965).

(26) .Arrhenius, G., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 328.

(27) Asada, E., Matsuda, S., Bunseki Kagaku, 15,1104 (1966).

(28) Ashby, W. D., Proctor, E. M., Picker Analyzer, 4, No. 1 (1965), Picker X-Ray Corp., Cleveland, Ohio.

(29) Austin, A.-E., Richard, N. A,, Wood, V. E., J . Appl. Phys., 37,3650 (1966).

(30) AaarofT, L. V., Science, 151, 785 (1966).

(31) Babusci, D., Anal. Chim. Acta, 32,175 (1965).

(32) Backerud, L., Appl. Spectry., 21, 315 (1967).

(33) Baird, A. K., Zenger, D. H., Advan. X-Ray Anal. 9,487 (1966).

(34) Baker, P. S., Gerrard, M., Eds.,

(35) Baker, P. S., Gerrard, M., Eds., Proc. 2nd Symp. on Low Energy X- and Gamma Sources and Applications,

IIC-10,764 (1967).

ICC-10 315 (1967).

ORNL-IIC-5 (1965).

Austin, Texas, Sept. 1967, ORNL- IIC-10.

(36) Baker, T. N., J . Iron Steel Inst., 205,315 (1967).

(37) Banks, M. S., Lucas-Tooth, H. J., presented in part a t the 16th Annual Conf. on Applications of X-Ray Analy- sis, Denver, Colo., August 1967.

(38) Baun, W. L., Fischer, D. W., J . Appl. Phys., 38,2092 (1967).

(39) Baun, W. L., Fischer, D. W.,

(40) Baun, W. L., Fischer, D. W., pre- sented in part a t the Second National Conf. on Electron Microprobe Analysis, Boston, June 1967.

(41) Baun, W. L., Fischer, D. W., pre- sented a t Colloq. Spectros., 13th, Ottawa, 1967.

(42) Beaman, D. R., Anal. Chem., 38, 599 (1966).

(43) Ibid., 39,418 (1967). (44) Beaman, D.YR., 2nd Natl. Conf. on

Electron Microprobe Analysis, Boston, Mass., 1967.

(45) Beard, D. W., Proctor, E. M., Advan. X-Ray Anal., 10,506 (1967).

(46) Bearden, A. J., J . Appl. Phys., 37, 1681 (1966).

ORNLIIC-10,557 (1967).

(47) Bearden, J. A., Rev. Mod. Phys.,

(48) Bearden, J. A., Burr, A. F., Ibid., 39,78 (1967).

n 12.5 ---. (49) Becherer, G., Herms, G., Motafeld,

V., J . Sci. Znstr., 42, 754 (1965). (50) Beingessner, C. J., Galibois, A.,

Winegard, W. G., Trans. Met. SOC. AIME, 233,2036 (1965).

(51) .Belk, J. , A., “X-Ray Optics and Microanalysis," Hermann, Paris, 1966, p 214.

VOL 40, NO. 5, APRIL 1968 369 R

Page 25: X-ray absorption and emission

(52) Belk, J. A., Clayton, B., Zbid., p 409.

(53) Bergmann, J. G.,. Ehrhardt, C. H., Granatelli, L., Janik, J. L., ANAL. CHEM., 39,1258 (1967).

(54) Ibid., p 1331. (55) Bernstein, F., Mattson, R. A,,

Advan. X-Ray Anal., 10, 494 (1967). (56) Berry, P. F., Can. Mining Met.

Bull., 70, 1 (1967). (57) Berry, P. F., ORNL-IIC-10, 870

(1967). \ - - - . ,. (58) Berry, P. F., Tolmie, R. W., STI/

(59) Berthold. H. J.. Ankner. D.. Z. PUB/112,505 (1966).

, , Anal. Chem.’. 226. 13 i1967).

(60) Bertin, E. P.; Advan X-Ray Anal., 10,462 (1967).

(61) Betin, Y. P., Bursukova, M. I., Shelkov, L. S., Zavodsk. Lab., 31, 1821 (1965) (Eng. ed.).

(62) Biloni, H., Bolling, G. F., Domian, H. A., Trans. Met. SOC. AZME, 233, 1926 (1966).

(63) Binns, R. A., Mineral. Mag., 35, 561 (1965).

(64) Birks, J. B., “The Theory and Prac- tice of Scintillation Counting.” Per-

“I

gamon, Sew York, 1964. (65) Birks, L. S., Bunko Kenkyu, 13,

7 (1964). (66) Birks, L. S., Labrie, R. J., Criss,

J. I?., ANAL. CHEY., 38, 701 (1966). (67) Bishop, H. E., Brit. J . Appl. Phys.,

18,703 (1967). (68) Bishop, H. E., “X-Ray Optics and

Microanalysis,” Hermann, Paris, 1966,

(69) Blank, 0. R., Dingeldein, W. H., NLCO 955 (June 1965).

(70) Ibid., NLCO 963 (1965). (71) Bloch, R., Mikrochim. Acta, 440

(196.51.

p 112.

\ - - - - ,

(72) Bloch, R., Kulmburg, A,, Swoboda, K., Mikrochim. Acta, Suppl. 1, 232 . _ (1966).

(73) Blokhin, M. A., “Metpds of X-Ray Spectroscopic Research, Pergamon, London, 1965.

(74) Blokhin, M. A., Duimakaev, S. I., Karrnanov, V. I., Zavodsk. Lab., 31, 1818 (1965) (Eng. ed.).

(75) Bojarski, Z., Barszce, E., Zielinski, S., J . Iron Steel Znst., 203, 792 (1965).

(76) Bonatti, E., Science, 153,. 534 (1966). (77) Bonissoni, G., Paganelli, M., Met.

Ital., 8,268 (1966). (78) Boniszewski, T., Boniszewski, E.,

J . Iron Steel Inst., 204, 360 (1966). (79) Borom, M. P., Hanneman, R. E.,

J . Appl. Phys., 38,2406 (1967). (80) Borom, M. P., Longwell, J. A.,

Pash, J. A., J . Am. Ceram. SOC., 50, 61 (1967).

(81) Bottinga, Y., Kudo, A., Weill, D., Amer. Mineralogist, 51, 792 (1966).

(82) Bowie, S. H. U., Darnley, A. G., Rhodes, J. R., Trans. Znst. Mining Met. (London), 72, 361 (1964-65).

(83) Bowman, H. R., Hyde, E. K., Thompson, S. G., Jared, R. C., Sci- ence. 151.562 (1966).

(84) Bradbury, B. T., Demant, J. T., Martin, P. M., Poole, D. M., J . Nucl. Mater., 17,227 (1965).

(85) Bradlei., W. H., Huebner, R. H., Wichman, F. H., “Xuclear Spectrom- eter Applications,” Nuclear Measure- ments Corp., 218 pp (1962).

(86) Brandt, W., Laubert, R., Sellin, I., Phys. Rev., 151,56 (1966).

(87) Bratton, R. J., Tien, T. Y., J . Am. Ceram. Soc.. 50.90 (1967).

I . . I

(88) Braybrook, R. F., Franks, A,, Kirby, F. J., Lindsey, K., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 477.

(89) Brinkerhoff, J. M., Forsyth, R., AEC NYO 3160 1 (December 1965).

(90) Brockman, R. H., Whittem, R. N.,

(91) Broquet, C., Robin, G., Vacher,

(92) Brown, D. B., Seminar on Electron Probe Microanalysis, Natl. Bur. Stds., Gaithersbur Md., June 1967.

(93) Brown, 8. B., Ogilvie, R. E., J. Appl. Phys., 37,4429 (1966).

(94) Brown, D. B., Wittry, D. B., 2nd Natl. Conf. on Electron Microprobe Analysis, Boston, Mass., 1967.

(95) Brown, J. D., ANAL. CHEM., 38, 890 (1966).

(96) Brown. J. D.. Ph.D. Thesis. Univ.

AAEC TM 321 (1966).

M., ORNL-ICC-10,356 (1967).

‘ of Maryland, ’College Park,’ Md., (1966), 167 pp.

(97) Brown, J. G., “X-Rays and Their Applications,” Plenum Press, New York, 1966.

(98) Bruce, T., Ashley, R. W., AECL- 2648 (19661.

\ - - - - I

(99) Bruch, H., Loeffler, C., Grisar, U., Werkstoffe Korrosion, 17, 685 (1966).

100) Brunina, F. J., Thielmann, H., Rheinstahl.Tech., 1,34 (1963).

101) Bucksch, R., Hesse, J., Mikrochim. Acta Su pl . 1,203 (1966).

102) BurEo E. H. S., “The Auger Effect,” Ckmbridge Univ. Press, En- gland, 1952.

103) Burke, K. E., Yanak, M. M., Al- briaht, C. H., ANAL. CHEM., 39. 14 , . (1937 j.

104) Burkhalter, P. G., Brown, J. D., Myklebust, R. L., Rev. Sci. Instr., 37,1267 (1966).

(105) Burkhalter, P. G., Campbell, W.

(106) Burns, R. G., Fuerstenau, D. W., Amer. Mineralogist, 51, 895 (1966).

(107) Busch, A. J., Goldbeck, C. G., NBL 230, p 76 (1965).

(108) Cameron, J. F., ORNL-IIC-10, 903 (1967).

(109) Cameron, J. F., Rhodes, J. R., Intern. J . Avvl. Radiation Zsotoves. 7.

J., ORNL-IIC-10,393 (1967).

‘ . . . . 244 (1960). 10) Cameron, J. F., Rhodes, J. R., A’ucleonics, 19,53 (1961). 11) Campbell, A. J., Norelco Reptr., 14, 103 (1967). 12) Campbell, J. K. R., Watson, L. M., Fabian, D. J., J . Sci. Znstr., 44, 21 (1964). \ ~ . _ _ , .

13) Campbell, J. L., Ledingham, K. W. D., Brit. J . Appl. Phys., 17, 769 (1966). 14) Campbell, J. T., Hammond, T.,

(115) CamDbell, W. J., “X-Ray and Elec- AERE R-4534 (1966).

‘ tron Meihodk of Analysis,”- Wm. Par- rish, Ed., Plenum Press, Sew York, 1968. n 38.

(116)-C&pbell, W. J., Brown, J. D., ANAL. CHEM., 36,312R (1964).

(117) Campbell, W. J., Brown, J. D., Thatcher, J. W., Zbid., 38. 416R (1966).

(118) Campbell, w. J:, Spano, E. F., Green, T. E., Ibid., p 987.

(119) Carlsson, R., Fahlman, A., Sieg- bahn, K., Arkiv Fys i k 32, 103 (1966).

(120) Carpenter, L., Nishi, J. M., Fehler, R . H.. Avvl. Svectrv., 20. 359 (1966).

(121) CarrIBrion, K: ’ G.,‘ Analyst, 91,

(122) Carr-Brion. K. G.. Trans. Inst. 1081 (1966).

‘ Mkning M e t . , 76, C94 (1967). (123) Carr-Brion, K. G., Jenkinson, D. A.,

Brit. J. Avvl. Phus., 17. 1103 (1966). (124) Carr-Biion, K. ’G.,’ Jenkinson,. D.

A., J . Sci. Instr., 42, 817 (1965). (125) Carr-Brion, K. G., Mitchell, P.

J., J . Sci. Instr., 44,611 (1967). (126) Carr-Brion, K. G., Rhodes, J. R.,

12th International Spectry. Colloq., University of Exeter, 1965.

(127) Carter, G. F., Science, 151, 196 (1965).

(128) Carter, R. W., Rohrer, R. H.,

Carlton, W. H., Dyer, G. R., Health Phys., 13,593 (1967). 29) Castaing, R., Derian, J. C., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 193. 30) Castaing, R., Descamps, J., J. Phys. Radium, 16,304 (1955). 31) Castaing, R., Descamps, J., Phili- bert, J., Eds., “X-Ray Optics and X-Ray Microanalysis,” Hermann, Paris, 1966. 32)Castaing, R., Henoc, J., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 120.

(133) Castaing, R., Pichoir, F., NASA TT

(134) Castaing, R., Pichoir, F., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 454.

(135) Casteels, F., J. Less-Common Metals, 12.210 11967).

F-422 (1965).

(136) Casho, ’R., LeFevre, J., Rev. Met. Mem. Sci., 63,571 (1966).

(137) Castro, R., LeFevre, J., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 588.

(138) Cavailles, J., Martinelli, P., STI/ PUB/112,227 (1966).

(139) Chamberlain, B. R., Leech, R. J., Talanta, 14,597 (1967).

(140) Champion, K. P., Taylor, J. C., Whittem, R. N., ANAL. CHEM., 38, 109 (1966).

(141) Champion, K. P., Whittem, R. N., Analyst, 92, 112 (1967).

(142) Chan, F. L., Advan. X-Ray Anal., 9,515 (1966).

(143) Chan, F. L., Proc. SAC Confer- ence. Nottinaham. UT. Heffer and Sons, 1965. D 89. -

(144) Chow, A., Beamish, F. E., Taluntu, 13,539 (1966).

(145) Chow, E., T-K., Cocozza, E. P., Appl. Spectry., 21,290 (1967).

(146) Christensen, L. J., Khan, J. M., Brunner, W. F., Rev. Sci. Znstr., 38, 20 (1967).

(147) Christian, H., Schaaber, O., Haer- terei-Tech. Mitt., 19,209 (1964).

(148) Zbid., 21,210(1966). (149) Christian, H., Schaaber, O., Mikro-

chim. Acta, Suppl. 1, 120 (1966). (150) Clark, A. M., Stumpfl, E. .F;!

“X-Rav ODtics and Microanalvsis. “ I

Hermakn, P’aris, 1966, p 277. (151) Clarke, R. S., Jr., Wosinski, J. F.,

Geochim. Cosmochim. Acta. 31, 397 (1967).

(152) Cline, J. E., Schwartz, S., J . Elec- trochem. SOC., 114,605 (1967).

(153) Cocozza, E. P., Ferguson, A., Appl. Spectry., 21,286 (1967).

(154) Colby, J. W., Conley, D. K., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 263.

(155) Colby, J. W., Wise, W. N., Conley, D. K., Advan. X-Ray Anal., 10, 447 (1967).

(156) Conty, C., Finley, P., 2nd Natl. Conf. Electron Microprobe Analysis, Boston, Mass., 1967.

(157) Cooke, C. J., Duncumb, P., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 467.

(158) Cooper, L. R., Lawrence G. A., British Patent 1,045,874 (1966).

(159) Corbett, J. M., Boswell, F. W., J. Appl. Phys., 37,2016 (1966).

(160) Cosslett, V. , E;, “X-Ray Optics and Microanalysis, Hermann, Paris, 1966, p 85.

(161) Cowgill, U. M., ORNL-IIC-10, 613 (1967).

(162) Craig, C. R., “Improved Lead Blast Furnace Control by X-Rax Emission Spectrography of Slags, Cerro de Pasco Corp. Research Dept., Sierra Div., La Oroya, Peru, 1967.

(163) Crawford, W. O., McHenry, W. D., AD620141 (June 1965).

370 R e ANALYTICAL CHEMISTRY

Page 26: X-ray absorption and emission

(164) Criss, J. R., 2nd Xatl. Conf. Elec- tron Microprobe Analysis, Boston, ?rIass., 1967.

(165) Cropper, W. P., et al., U. S. Patent 3,210,541 (1965).

(166) Culhane, J. L., Herring, J., San- ford, P. IT., O’Shea, G., Phillips, R. D., J . Scz. Instr., 43, 908 (1966).

(167) Czanianske, G. K., Hower, J., Millard, R. C., Geochim. Cosmochim. Acta, 30, 745 (1966).

(168) llarigny, E., Robin, G., ORNL-IIC- 10,786 (1967).

(169) I>arnley, A. G., Gallagher, M. J., Trans. Inst. Mining Met., 75, BlO5 (1966).

(170) Ilarnley, A. G., Leamy, C. C., STI/PUB/112, 191 (1966).

(171) Ilas, H. *4., Zonderhuis, J., Rec. Trav. Chiin., 85, 837 (Aug. 1966).

(172) Das Gupta, K., Schnopper, H. W., Xetzger, A. E., Shields, R. A., Advan. X-Ray Anal., 9, 221 (1966).

(173) llavey, J. P., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 566.

(174) Davidson, E., Gilkerson, A. W., Shequen, W. G., A R L ,Vewsletter, 19, 1 (1966).

(175) Davidson, F. D., Ryckoff, R. W. G., Adaan. X-Ray Anal., 9,344 (1966).

(176) Davidson, F. D., Wyckoff, R. W. G., Sorelco Reptr., 14, 3 (Jan. 1967).

(177) llearnaley, G., J . Scz. Instr., 43, 869 (1966).

(178) De Beer, Z., Creton, F., Met. Ital., 8,308 (1966).

(179) De Gelas, B., Berranger, G., Marion, G., Lacombe, P., J . .Vucl. Mater., 20,337 (1966).

(180) Ileniyanikov, I. G., Chernitsyna, I. I., Zavodsk. Lab., 32, 1319 (1966).

(181) Deslattes, It. D., LaVilla, R. E., Appl. Optzcs, 6,39 (Jan. 1967).

(182) Deslattes, R. D., Simson, B. G., Rev. Sci. Instr., 37, 753 (1966).

(183) Dewey, R,. D., “Computed X-Ray Wavelengths, Reynolds Metals Co., Richmond. \‘a. 1 1966).

(184) Iliaz, ’ L. S., -Anderson, R. J., Mzntng Congr. J . , p 94, July 1965.

(185) Dickens, P., Z. Anal. Chem., 209, 136 (1y65).

(186) Diehl, W., Ibzd. , 222, 178 (1966). (187) Dodd, R. T., Jr., Van Schmus, W. R., Marvin, U. B., Am. Mineral- ogzst, 51, 1177 (1966).

(188) Dorfler, G., Seminar on Electron Probe Microanalysis, Natl. Bur. Stds. Gaithersburg, hld., June 1967.

(189) Ilorfler, G., Plockinger, E., “X-Ray ODtics and hficroanalvsis.” Hermann. Paris, 1966, p 506.

(190) Dorfler, G., Plockinger, E., Swo- boda, K., Berg Iluettenmaenn. Monatsh. Montan. Hochschule Leoben, 11 1, 438 (1966).

(191) Dornelas, IT., Lacombe, P., J . Xucl. Mater., 21, 100 (1967).

(192) Ilorsey, J. R., 1st Natl. Conf. on Electron Probe Microanalysis, College Park, M d ~ , 1966.

(193) Ihimakaev, S. I., Blokhin, M. A., Zavodsk. Lab., 31, 1328 (1965) (Eng. Ed.).

(194) Duncumb, P., DaCasa, C., 2nd Natl. Conf. on Electron RIicroprobe Analysis, Boston, Mass., 1967.

(195) Duncumb, P., Melford, D. A., 1st Satl . Conf. on Electron Probe Microanalysis, College Park, hfd., 1966.

(196) Duncumb, P., Melford, D. A.,

Hermann, Paris, 1966, p 240. (197) Duncumb, P., Reed, S. J. B., Sem-

inar on Electron Probe Microanalysis, Natl. Bur. Stds., Gaithersburg, Md.,

I t X 7- Ray Optics and hficroanalysis,”

.Tiinp 1967 -

(198) Dunne, J. A., Xorelco Reptr., 13, 21 (1966).

(199) Dunne, J. A,, Nickle, S. L.,

(200) Ebel, H., Jax, J., Perez, P. R., 2. Angew. Phys., 13,20 (1966).

(201) Eckhard, S., Mikrochim. Acta, 3,37 (1965).

(202) Eckhard, S., Marotz, R., Z. Anal. Chem., 215,23 (1966).

(203) Ehlert, R. C., AFML-TR-66-281 (Aug. 1966).

(204) Ehlert, R. C., Mattson, R. A., Advan. X-Ray Anal., 9, 456 (1966).

(205) Ibid., 10,389 (1967). (206) Eick, J. D., Caul, H. J., Smith,

D. L., Rasberry, S. D., Appl. Spectry., 21,324 (1967).

(207) Elad, E., Xucl. Instr. Methods, 37,327 (1965).

(208) Elad, E., Nakamura, M., Zbid., 42,315 (1966).

(209) Elion, H. A., “Instrument and Chemical Analysis Aspects of Electron Microanalysis and Macroanalysis,” Prog. Nucl. Energy, Ser. 9, Vol. 5, Pergamon Press, 1966.

(210) Emmericz, R., Gilewice Wolter, J., Holynska, B., Zavodsk. Lab., 32, 193 (1966) (Eng. Ed.).

(211) Enomoto, S., Tanemura, T., STI/ PUB/l12,97 (1966).

(212) Erdmann-Jesnitzer, F., Feustel, E., Kraljic, P., Vollath, D.. Mikrochim. Acta. S u m l . 1. 148 (1966).

ORNL-IIC-10,336 (1967).

(213) Estil‘l,‘ W: B.,‘Rob&tson, M. M.,

(214) Estill, W. B., Robertson, M. M.,

(2153 Faber, G.. Huei. R.. Konirrer. M..

Rev. Sci. Instr., 37, 1650 (1966).

Conrad, G. H., Zbid., 38,481 (1967).

Brown Roueri Rev.,-53, 160 (196%).’ ‘

(216) Fadley, C. S., Hagstrom, S. B. M., Hollander, J. M., Klein, M. P., Shirley, D. A., Science, 157, 1571 (1967).

(217) Fahlman, A., Hamrin, K., Axelson, G., Nordling, C., Siegbahn, K., 2. . . Physik, 192,484 (1966). -

(218) Fahlman. A.. Hamrin. K.. Hedman. J.,‘ Sordberg, R., Sordling,’ C., Siegl bahn, K., Nature, 210,4 (1966).

(219) Fahlman, A., Hamrin, K., Xord- berg, R., Nordling, C., Siegbahn, K . Phys. Letters, 20, 159 (1966).

(220) Fahlman, A., Hamrin, K., Nord- berg, R., Nordling, C., Siegbahn, K., Holm, L. W., Ibid., 19, 643 (1966).

(221) Fahlman, A., Kordberg, R., Norl- ing, C., Siegbahn, K., 2. Physik, 192,476 (1966).

(222) Fahlman, A., Siegbahn, K., Arkiu Physik, 32,111 (1966).

(223) Faulring, G. hl., hlalizie, E. S., Advan. Z-Ray Anal., 10, 409 (1967).

(224) Feingold, E., Sutton, W. H., Sauer, IT. E., U. S. Army, AMRA CR 66- 01/2 11966). - , - \ - - I

(225) Fergason, L. A,, Advan. X-Ray

(226) Fergason, L. A., Anal. Chem., 38. Anal., 9,265 (1966).

I ,

1955 (1g66).

964 11966’1. (227) Fergason, L., Rev. Sci. Instr., 37,

(228) Fink,’R. IT., Jopson, R. C., hlark, H., Swift, C. D., Rev. .llod. Phys., 38,513 (1966).

(229) Fischer, D. W., J . Appl. Phys., 36.2048 (1965).

(230j Fischer, D. W., Baun, W. L., Advan. S-Ray Anal., 9, 329 (1966).

(231)Fischer, D. W., Baun, W. L., Advan. S-Ray Anal., 10, 374 (1967).

(232) Fiqcher, D. R., Baun, W. L., AFMLTR 65 360 119653.

(233) Fischer, D. IT., Baun, W. L., J .

(234) Ibid., 38,229 (1967). (235) Ibid., p. 2404. (236) Fischer, D. W., Baun, W. L., Phys.

Rev., 145, 555 (1966). (237) Fischer, D. W., Baun, W. L., The

Influence of Sample Self Absorption on

Appl. Phys., 37,768 (1966).

Wavelength Shifts and Shape Changes, in the Soft X-Ray Region. The Rare Earth M Series, presented a t the Denver Conference on X-Ray Analysis, August 1967.

(238).Fischer, D. W., Baun, W. L., Wright Patterson Air Force Base, Ohio Tech. Rept., AFML TR 65 255 (1965).

(239) Ibid., AFML TR 66 191 (1966). (240) Fischer, W., Biesenberger, K., Boh-

mer, W., Reinhardt, K., 2. Anal. Chem., 216,61(1966).

(241) Flechon, J., Fleck, J. P., Bull. SOC. Chim. France, 8, 2189 (1965).

(242) Forbes, R. B., Banno, S.. Am. Mineraloaist. 51. 130 (1966).

(243) Francis,’ J. ’hl., ‘Whitlow, W. H.,

(244) Francs, R. P., Davidson, F. D., J . Iron Steel Inst., 204, 355 (1966).

Rev. Sci. Instr., 36, 230 (1965). (245) Frazer, J., 2nd Natl. Conf. on

Electron Microprobe Analysis, Boston, Mass., 1967.

(246) Frazer, J., Arrhenius, G., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 516.

(247). Frazer, J. Z., Fitzgerald, R. W., Reid, A. M., Scripps Inst. Oceanography, La Jolla, Calif., Ref. 66-14 (1966).

(248) Frazer, J. Z., Reid, A. M., 2nd Natl. Conf. on Electron Microprobe Analysis, Boston, Mass., 1967.

(249) Frazier, P. I)., Arch. Oral. Biol., 12,25 (1967).

(250) Freck, D. V., British Patent 1,018,- 493 (1966).

(251) Fredriksson, K., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 305.

(252) Fuchs, E., Rev. Sci. Instr., 37, 623 (1966).

(253) Fuchs, E., Rehme, H., Mikrochim. Acta, Suppl. 1,97 (1966).

(254) Fuchs, L. H., Frondel, C., Klein, C., Jr., Am. Mineralogist, 51, 949 f1966’l. \ - - - - , -

(255) Furbee, A. D., U. S. Patent 3,198,- 944 (1965).

(256) Galle, P., “X-Ray Optics and hlicroanalysis,” Hermann, Paris, 1966, D 670.

(267) Garnes, G. A., Ed., Norelco Reptr., 14,75 (1967).

(258) Carton, F. 1%’. J., Campbell, J. T., Watling, J., “Proc. SAC Conference, Nottingham,” 65 (1965), W. Heffer and Sons Ltd., Cambridge, England.

(259) Gates, 0. R., Brooks, E. J., S R L Rept., 6427 (1966).

(260) Gianni, F., Vetere, A,, Met. Ital., 8,285 (1966).

(261) Giraud-Heraud, F., Sifferlen, R., Saulnier, A,, J . Microscopie, 4, 587 (1965).

(262) Goadby, S. C., Stephens, J. F., Fuel, 46,19 (1967).

(263) Goldman, M., Hui, C. K., Ander- son, R. P., UCD 472 112 (1966).

(264) Goldstein, J. I., hlajeske, F. J., Yakowitz, H., Advan. X-Ray Anal., 10.431 (1967).

(2655 Goldstein, J. I., RIajeske, F.. J., Yakowitz, H., Goddard Space Flight Center, Greenbelt, Md., X-641-66-361 (1966).

(266) Goldstein, J. I., Ogilvie, R. E., Trans. Met. SOC. AIJIE, 233, 2083 (1965).

(267) Goldstein, J. I., Ogilvie, R. ,E;! “X-Ray Optics and Microanalysis, Hermann, Paris, 1966, p 594.

(268) Goldstein, J. I., Short, J. M., Geochim. Cosmochim. Acta, 31, 1001 (1967).

(269) Goldstein, J. I., Wood, F., 1st Natl. Conf. on Electron Microprobe Anal rsis, College Park, Md., 1966.

(270) 6 oulding, F. S., Nucl. Instr. Meth- ods, 43, 1 (1966).

VOL. 40, NO. 5, APRIL 1968 0 371 R

Page 27: X-ray absorption and emission

(271) Graber, H. D., Watson, D. D.,

(272) Grodski, J. J., Norelco Reptr., 14, Ibid., 355.

107 (1967). \ - - - . , - (273) Groot, T., Bruijs, P. C.

beek, J. H. T. C., Nature, M. N., 5053,

Ver- 1085

(1966).

Anal. Chem.. 216.66 11966). (274) Grothe, K. H., Krause, G., Z.

(275) Ibid., 217,54’(1966). ’

(276) Gunnink, R., Levy, H. B., Xiday, J. B., UCID 15140 (1967).

(277) Guttmann, A. J., Wagenfeld, H., Acta Crystallog., 22,334 (1967).

(278) Hahn-U7einheimer, P., Johanning, H., Ackermann, H., Z. Anal. Chem., 214, 16 (1965).

(279) Hakkila, E. A., Hurley, R. G., Waterbury, G. R., ANAL. CHEM., 38, 425 (1966).

(280) Hakkila, E. A., Waterbury, G. R., Ibid., 37,1773 (1965).

(281) Hale, A. J., Hall, T. A., Curran, R. C., “X-Ray Optics and Micro- analysis,” Hermann, Paris, 1966, p 686.

(282) Hall, C. R., Proc. Roy. SOC. (Lon- don) , 2958,140 (1966).

(283) Hall, T., Seminar on Electron Probe Microanalysis, Yatl. Bur. Stds., Gai- thersburg, Md., June 1967.

(284) Hall, T: R., “X-Ray Optics and Microanalysis, Hermann, Paris, 1966, p 679.

(285) Halliday, F. O., Keast, A. K., Kel- man, J. F., Passell, T. O., J . Appl. Physics, 38,1874 (1967).

(286) Hanneman, R. E., Lifshin, E., Trans. Met. SOC. AIME, 236, 1503 i 1966’i \ - _ - _

(287) Harris, D. C., Ph.D. Thesis, Univ. of Toronto, Canada, 1965.

(288) Harris, D. C., Brooker, E. J., Can. Mineralogist 8,471 (1966).

(289) Harris, L. A., Chem. Eng. News, Aug. 21, 1967, p. 14.

(290) Harris, L. A., General Electric R and D Center, Rept. 67-c-199, May 1967.

(291) Zbid., 674-201, May 1967. (292) Hart, R. K., U. S. At. Energy

Comm., ANL-7078 (1965). (293) Hayden, J. A., Talanta, 14, 721

(1967). (294) Heath, R. L., AEC Rept. I D 0

16880. Vols. 1 and 2, 2nd ed. (August . I

1964 ) .’ (295) Heath, R. L., Nucl. InsCr. Methods,

43,209 (1966). (296) Heath, R. L., ORNL-IIC-10, 424

(1967). (297) Hehenkamp, T., “X-Ray Optics

and Microanalvsis,” Hermann, Paris, I .

1966, p 350.

39, No. 8,74A (1967).

Tech. ;2Tote 278,39 pp. (1967).

(298) Heinrich, K. F. J., ANAL. CHEX.,

(299) Heinrich, K. F. J., Natl. Bur. Std.

(300) Ibid., 284 (1966). (301) Heinrich, K. F. J., 2nd Satl. Conf.

Electron Microprobe Analysis, Boston, Mass., 1967.

(302) Heinrich: K. F. J., “The Electron Microprobe, \%ley, Sew York, 1966, p 295.

(303) Heinrich, K. F. J., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 159.

(304) Heinrich, K. F. J., Veith, D., Yakowitz, H., Advan. X-Ray Anal., 9,208 (1966).

(305) Heinrich, K. F. J., Yakowitz, H., 1st Xatl. Conf. on Electron Probe Microanalysis, College Park, Md., 1966.

(306) Heinrich, K. F. J., Yakowits,. H., 2nd Natl. Conf. on Electron Micro- probe Analysis, Boston, Mass., 1967.

(307) Helgesson, C. I., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 284.

Ibid., p 608. Henke, B. L., Advan. X-Ray Anal.,

:310) Henke, B. L., ORNL-IIC-10. 522 9,430 (1966).

( (1967).

(311) Henke, B. L., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, D 440.

(3i2) Henke, B. L., Elgin, R. L., Lent, R. E., Ledingham, R. B., AFOSR 67- 1254 ( 1 967) ---- \---. /.

(313) Henke, B. L., Smith, E. N., J. Appl. Phys., 37,922 (1966).

(314) Hermes, 0. D., Raglund, P. C., Am. Mineralogist, 52,493 (1967).

(315) Hillert, M., Wada, T., Wada, E., J. Iron Steel Znst., 205,539 (1967).

(316) Hink, W., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 143.

(317) Hirata, H., Amemiya, A,, Date, K., Japan Analyst, 16,99 (1967).

(318) Hirokawa, K., Goto, H., Sci. Rept. Sendai Tohoku Univ., Ser. A, Vol. 18 (1966).

(319) Hobby, M. G., Wood, G. C., Metallurgia, 75,143 (1967).

(320) Hoehling, H. J., Hall, T. A,, Boothroyd, B., Cooke, C. J., Duncumb, P., Fitton-Jackson, S., Naturwissen- schajten, 54,142 (1967).

(321) Hoehling, H. J., Hall, T. A., Fearnhead, R. W., Zbid., p. 93.

(322) Hoerman, K. C., Klima, J. E., Birks, L. S., Nagel, D. J., Ludwick, W. E., Lyon, H. W., Norelco Reptr., 14, 69 (1967).

(323)’ HI%- W. D., Gregory, B., Metal-

(324) Holland, J. G., Brindle, D. W.,

(325) Hollander. J. M.. Nucl. Instr.

lurgia, 72,99 (1965).

Spectrochim. Acta, 22, 2083 (1966).

’ Methods, 43,65 (1966). ’

(326) Hollander, J. M., UCRL 16307 I 1 96.5). \--”-, .

(327) Hollander, J. M., Perlman, I.,

(328) Hollidav. J. E., Advan. X-Rav Science, 154,84 (1966).

. Anal., 9,36511966). ‘

(329) Hollister, L. S., Ph.D. Thesis, Calif. Inst. Tech., Pasadena, Calif., il966’i229nn. \ - - - - I --- rr- ORNL-IIC-10,483 (1967).

(330) Hollstein, M. G., DeVoe, J. R.,

(331) Holvnska, B., Chem. Anal. (War- saw), 11; 647 (1966).

(332) Hooper, K., J. Paleontology, 38, 1082 (1964).

(333) Hostetler, P. B., Coleman, R. G., Mumpton, F. A., Evans, B. W., Am. Mineralogist, 51,75 (1966).

(334) Hater, F., Mikrochzm. Acta, 494 (1965).

1335) Howie. R. A.. Smith. J. V.. J . ~ Geol., 74,443 (1966). (336) Hubbard, F. H., Am. Mineralogist,

51,762 (1966). (337) Hudgens, C. R., Roesch, D. L.,

Nucl. Znstr. Methods, 40, 157 (1966). (338) Huffman, F. S., Ph.D. Thesis,

Johns HoDkins Univ. (1964). (339) Hughks, G. D., Woodhouse, J. B.,

“);-Ray Optics and Microanalysis,” Hermann. Paris. 1966, D 202. . _

(340) Hurley, It.‘ G., Hakkila, E. A., Waterbury, G. R., LA 3549 (1966).

(341) Hutchins, G. A., Wantman, R. D., 2nd Natl. Conf. on Electron Micro- probe Analysis, Boston, Mass., 1967.

(342) Huth, G. C., Locker, R. J., ORNL- IIC-10.574 (1967).

(343) Hide, E. K., Bowman, H. R., Sisson, D. H., UCRL-16578 (1966).

(344) Zbid., UCRL-16845. (345) Il’in, N. P., Loseva, L. E., Zavodsk.

Lab., 32,664 (1966) (Ens. Ed.). (346) Ingersoll,‘ R. ‘ i f . , -Ta lor, J. E.,

Derouin, D. H., Advan. 2 R a y Anal., 9,273 (1966).

(347) Ingram, M. J., Hogben, C. A. M., Anal. Biochem., 18,54 (1967).

(348) Intern. At . Energy Agency, Radio- isotope Instruments in Industry and Geophysics, Vol. 1, STI/PUB/112 ( 1966 ).

(349) Irani, J. J., Weiner, R. T., J . Iron

(350) Ishii, Y., Japan Analyst, 14, 1120

(351) Jackson, C. N., Jr., Jacob, R. B.,

(352) Jeffery, B. M., J . Nucl. Mater.,

Steel Znst., 203,913 (1965).

(1965).

BNWL S A 264 (1965).

22.33 (1967). (353j Jeglitsch, F., Mikrochim. Acta,

479 (1965). (354) Jenkins, R., De Vries, J. L., “Prac-

tical X-Ray Spectrometry,” Springer- Verlag, N. Y., 1967.

(355) Johnson, M. P., Beeley, P. R., Nutting, J., J. Iron Steel Inst., January 1967. D. 32.

i,, -C_a_rpenter, R. A., (356) Jdnes, W. B ORNL-IIC-l0,46S (1Ybi).

(357) Jordan, E. D., Carew, T. E., AD625415 (146.5)

(358) Ka,&lo x-1 I I

(359) Kammel, R., Samans, R., \$?inter- hager, H., Mikrochim. Acta, Suppl. 1,192 (1966).

(360) Karev, V. N., Matushenko, N. N., &?odsk. Lab. 32, 1334 (1966) (Eng.

---yu.v, E. F., Ed., “Handbook of Ravs.” McGraw-Hill. N. Y.. 1967.

Ed.).

56,33 (1967).

(1965).

(361) Karttunen, J. O., Chemist-Analyst,

(362) Kathren, R. L., UCRL 14151 \ - - - - I

(363) Kato, M., ORNL-IIC-10,723 (1967). (364) Keil, K., Am. Mineral., 50, 2089

(1966). (365) Keil, K., Andersen, A., Geochim.

Cosmochim. Acta, 29,621 (1965). (366) Keil, K., Andersen, C. A,, Nature,

207,745 (1965). (367) Keil, K., Snetsinger, K. G., Sci-

ence, 155,451 (1967). (368) Kelley, T. K., Inst. Mining Met.

Trans. Sect. B 75,59 (1966). (369) Khan, J. M., Potter, D. L.,

Worley, R. D., J . Appl. Phys., 37, 564 (1966).

(370) Zbid., UCRL 7826 (1964). (371) Khan, J. M., Potter, D. L., Worley,

R. D., Smith, H. P., Jr., Phys. Rev., 148,413 (1966).

(372) Kienberger, C. A., Flynn, A. R., Report K1638 (Jan. 1966) Union Car- bide Corp., Oak Ridge, Tenn.

(373) Kiessling, R., Hassler, B., Westman, C., J . Iron Steel Znst., 205,531 (1967).

(374) Kiessling, R., Westman, C., J. Iron Steel Inst., 204,377 (1966).

(375) Kim, Y. S., ANAL. CHEM., 39, 664 11967).

(376) Kimoto, S., Hashimoto, H., Kosuge, T., Hert, W., Mikrochim. Acta, 471 I 1 96.5). \ - - - - I .

(377) Kimoto, S., Hashimoto, H., Tada, K., 2nd Natl. Conf. on Electron Micro- probe bnalysis, Boston, Mass., 1967.

(378) Kimoto, S., Hert, W., Mikrochim. Acta, Suppl. 1,108 (1966).

(379) Kimoto, S., Sato, M., Kamada, H., Ui, T., Advan. X-Ray Anal., 9, 508 (1966).

(380) Kinnunen, J., Rautavalta, P., Ko- ponen, M., Melallurgia, 75, 189 (1967).

(381) Kirchmayr, H. R., Acta Phys. Austr., 24, 234 (1966).

(382) Kirkendall, T. D., Varadi, P. F.,

(383) KirkDatrick. P.. Rev. Sci. Znstr.. ANAL. CHEM., 39, 1342 (1967).

I ,

~ IO, 186 (i939). (384) Kiss, L. T., ANAL. CHEM., 38, 1731

(385) Klecka, J. F., UCRL 17144 (1966). (386) Klecka, J. F., UCRL 17166 (1966). (387) Klemm, D. D., “X-Ray Optic8

(1966).

372 R ANALYTICAL CHEMISTRY

Page 28: X-ray absorption and emission

and Microanalysis,” Hermann, Paris, 1966. D 399.

(388) Klemperer, O., Rept. Progr. Phys. 28,77 (1965).

(389) Koch, W., Buchel, E., Mikrochim. Acta, 429 (1965).

(390) Kodama, H., Brydon, J. E., Stone, B. C.. Geochim. Cosmochim. Acta.

(391j Koffman; D. &I., Moll, S. H., Norton, J. T., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 333.

(392) Koffman, D. M., Schippert, M., Moll, S. H., Hamill, S., 2nd Natl. Conf. on Electron Microprobe Analysis, Boston. Mass.. 1967.

(393) Kdfstad, P., Espevik, S., J . Less- Common Metals, 12,117 (1967).

(394) Konno, S., Sagashima, A,, Abe, F., Asada, E.. JaDan Analvst 14. 1093 . , . (1965).

(395) Kornherr, M., Institut fur Plas- maphysik, Munich, IPP 1/32 (Feb. 1965).

(396) Kulmburg, A., Swoboda, A,, Mikro- chim. Acta, Supp. 1, 159 (1966).

(397) Kupriyanova, T. A., Zavodsk. Lab., 31,685 (1965) (Eng. Ed),.

(398) Kurat, G., Geocham. Cosmochim. Acta, 31,491 (1967).

(399) Kurat, G., Arlt, H. H., Mikrochim. Acta, Supp. 1,222 (1966).

(400) Laffolie, H. De, Arch. Eisenhut- tenw., 7,535 (1967).

(401) Larson, J. O., Winkler, R. A,, Guffy, J. C., Advan. X-Rau Anal.. 10,489 (1967).

‘ pejientia, 22,503 (1966). (405) Lavrent’ev, Y., Vainshtein, E.

E., Zavodsk. Lab., 31, 847 (1965) (Eng. Ed.).

(406) LeFevre, J., Castro, R., Met. Corros. Ind., 41,391 (1966).

(407) Lennartz, G., DeLaffolie, H., Dew Tech. Ber., 6,201 (1966).

(408) Lennartz, G., De Laffolie, H., Mikrochim. Acta, Suppl. 1, 174 (1966).

(409) Leontiadis, I., Comm. Energie At. (France), Rapp. CEA R 2970 (1966).

(410) Leroux, J., Mahmud, M., ANAL. CHEM., 38,76 (1966).

(411) Lewis, C. L., Ott,. IV. L., Sine, N. M., “The Analysis of Nickel,” Pergamon Press, 1966, p. 85.

(412) Liebhafsky, H. A,, U7ilkins, D. H., Bernstein, F., The Influence of X-Ray Emission Methods upon Research and Industry, Colloq. Spectros. Intern., 13th, Ottawa, 1967.

(413) Liebhafsky, H. A., Winslow, E. H., Pfeiffer, H. G., ANAL. CHEM., 34, 282R (1962).

(414) Lifshin, E., Weininger, J. L., Electrochem. Technol., 5, 5 (1967).

(415) Loffler, C., Mikrochim. Acta. Suppl. 1,139 (1966).

(416) Loomis, T. C., Storks, K. H., Bell Laboratories Record, Jan. 1967, p 2.

(417) Losev, N. F., Afonin, V. P., Rev- enko, A. G., Zavodsk. Lab., 32, 517 (1966) (Eng. Ed.).

(418) Losev, N. F., Smagunova, A. N., Belova, R. A., Studennikov, Y. A., Zavodsk. Lab., 32, 187 (1966) (Eng. Ed.).

(419) Lounanaa, N., Fugmann, W., Jern- kont. Ann., 150, 99-110 (1966), Eng. Translation avail. as BISI 5069 (Nov. 1966).

(420) Lubecki, A., Wasilewska, M., Gor- ski, L., Spectrochim. Acta, 23A, 831 (1967).

(421) Lux, F., Ammentorp-Schmidt, F.,

Opavsky, W., Z . Anorg. Allegem. Chem., 341,172 (1965).

(422) MacKay, K. J. H., 2nd Natl. Conf. on Electron Microprobe Analysis, Bos- ton, Mass., 1967.

(423) MacKay, K. J.,H., “X-Ray 0pti.m and Microanalysis, Hermann, Paris, 1966. D 544. , A ~~~

(424)Madlem, K. W., Advan. X-Ray Anal., 9,441 (1966).

(425) Mahr, C., Stork, G., Z. Anal. Chem., 222, 1 (1966).

(426) Malissa, H., “Elektronenstrahl- Mikroanalyse, Handbyh der Mikro- chemischen Methoden. Vol. 4. SDrin- ger-Verlag, New York, N. Y:, i966, 154 pp.

(427) Malissa, H., Mikrochim. Acta, 1965, 289

(428)’Malissa, H., Arlt, H. H., Kandler,

(429) Malissa. H.. Triebel. H.. Radex W., Ibid., 586.

I ,

~ Rundsch., 1966,344. (430) Mallett, G. R., Fay, M., Mueller,

W. M., Eds., Advan. X-Ray Anal., 9 (1966).

(431) Mamaev, V. E., Protasov, K. T., Sb. Nauch Trud. Vses. Nauchno-Issled. Gornmetallurg. Inst. Tsvet. Metall., 9, 163 (1965).

(432) Manners, V. J., Craig, J. V., Scott, F. H., J . Inst. Metals, 95, 173 (1967).

(433) Marcie, F. J., Environ. Sci. Technol., 1, 164 (1967).

(434) Margolinas, S., ORNL-IIC-10, 805 (1967).

(435)-Marks, C. L., Saylor, W. P., Sterk, A. A., ORNL-IIC-10, 587 (1967).

(436) la rsha l l , D. J., Hal1,T. A., “X-Ray ODtlCS and Microanalvsis.” Hermann. ” , P&s. 1966. D 374.

(437) hfartin,* T. C., Blake, K. R., Morgan, I. L., Parker, Jr., C. V., U.S. At. Energy Comm. OR0 3224 6 (1966).

(438) Martinelli, P., Bull. Inform. Sci. Tech. (Paris), ‘92, 79 (April l“965).

(1967). (439) Martinelli, P., Chimia, 21, 151

(440) Martinelli, P., Robert, A., Cav-

(441) Materials Advisory Board, Char- ailles, J., ORNL-IIC-10,696 (1967).

acterization of Materials MAB-229M, Clearinghouse for Federal Scientific and Technical Information, Springfield, Va.

(442) Maticich, J. R., M.Sc. thesis, Univ. of Calif., Los Angeles, Calif., 1964,116 pp.

(443) Mattson, R. A,, Ehlert, R. C., Advan. X_Ray Anal., 9, 471 (1966).

(444) Maurice, F., Seguin, R., Henoc, J., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 357.

(445) Mazanek, E., Jasienska, S., J. Iron Steel Inst., 204,344 (1966).

(446) McCrary, J. H., Plassmann, E. H., Puckett, J. M., Conner, A. L., Zimmer- mann, G. W., Phys. Rev., 153, 307 (1967).

Livermore, UCRL- (448) Melford, D. A,, Whittington, K. R.,

“X-Ray Optics and Microanalysis,” Hermann. Paris. 1966. D 497.

450) Menzies, I. A., Strafford J . Less-Common Metals, 12, 85 (196;

(451) Merritt, J., Agazzi, E. J., ANAL. CHEM., 38,1954 (1966).

(452) Merritt, J., Agazzi, E. J., Rev. Sci. Instr., 38, 127 (1967).

(453) Merx, H., Bull. SOC. Franc. Ceram., 67,53 (1965).

(454) Metzger, A. E., Parker, R. E., Trombka, J. I., Trans. Nuclear Sei., IEEE, 13,554 (Feb. 1966).

(455) Meyer, V. A., Nakhabtsev, V. S., Herald of Leningrad Univ. Yo. 12, p 65 (1965); Eng. Translation avail. from Clearinghouse for Federal Sci- entific and Technical Information, Springfield, Va.

(456) Mikrochim. Acta, (3) (1965) and Suppl.,l(l966).

(457) &files, M. J., Doremus, E. H., Valent, D., Rapid X-Ray Analysis of Titanium, Paper 236, Pittsburgh Conf. on Anal. Chemistrv and ADD^. Suet- *. . troscopy, 1966.

Sci. Instr.. 37. 115 (1966). (458) Miller, E. L., Wittry, D. B., Rev.

(459) Mille;, G. P., -M‘itchell, W. I., (460) Mitsche, R., Dichtl, H. J., Mikro-

J . Iron Steel Inst., 203,899 (1965).

chim. Acta, 1965,503.

berg. A.. Ibid.. 515. (461) Mitsche, R., Plockinger, E., Kulm-

(462)-Mitsche, R., Scheidl, H., Ibid., 551. (463) Miwa, H., Mizukoshi, T., Shimizu,

M., STI/PUB/112,213 (1966). (464) Montford, D. B., Spectroscopic

Determination of Metals in Water for the Canadian Light Water Reactor, pres. a t Colloq. Spectros. Intern., 13th, Ottawa, 1967.

(465) Moorhead, L. H., et al., AD 652 733 (1967).

(466) Morris, W. G., 2nd Natl. Conf. on Electron Microprobe Analysis, Bos- ton, Mass., 1967.

(467) Muller, D., Kernrnergie, 7, 249 (1964).

(468) Muller, R. O., “Spektrochemisch: Analysen mit Rontgenfluoreszenz, R. Oldenburg, Munich and Vienna, 1967.

(469) Myers, R. H., Womeldorph, D., Alley, B. J., ANAL. CHEM., 39, 1031 (1967).

(472) Xat‘elson; S., ORNL-IIC-10, 282 ( 1967).

(473) Satelson, S., Whitford, W. R., “Methods of Biochemical Analysis,” vol. 12, 1, Interscience, 1964.

(474) Sewkirk, J. B., Mallett, G. R., eds., Advan. X-Ray Anal., 10 (1967).

(475) Xicholson, A., Murray, J. D., J . Iron Steel Inst., 203, 1007 (1965).

(476) Nicholson, J. B., Hasler, M. F., Advan. X-Ray Anal., 9,420 (1966).

(477) Sicolas, J., Quintin, M., Douillet, P., Bull. SOC. Franc. Ceram. 74, 11 (1967).

(478) Niewodniczanski, J., STI/PUB/112, 173 (1966).

(479) Sikitin, F. V., Zavodsk. Lab., 31, 966 (1965).

(480) Xoack, J.,Z. Chem., 4,293 (1964). (481) Xordberg, R., Hamrin, K., Fahl-

man, A., Xordling, C., Siegbahn, K., Z. Physik., 192,462 (1966).

(482) Xorth, P. P., Norelco Reptr., 14, 10 (Jan. 1967).

(483) Xorton, J. T., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 487.

(484) Ogilvie, R. E., Brown, D. B., Ibid., p 139.

(485) Ogilvie, R. E., Moll, S. H., Koff- man, 1). M., ASD TDR 62-7 (1966).

(486) Old, C. F., Haworth, C. W., J . Inst. Metals, 94, 303 (1966).

(487) Olsen, E., Fredriksson, K., Geo- chim. Cosmochim. Acta, 30, 459 (1966).

(488) Ong, P. S., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 181.

(489) Openshaw, I. K., Pearce, R. J., Jeffery, B. M., Brit. J. Appl. Phys.,

(490) Openshaw, I. K., Swindells, N., 18,1004 (1967).

VOL. 40, NO. 5, APRIL 1968 373 R

Page 29: X-ray absorption and emission

“X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 555.

(491) Ostrowski, K. W., Gorski, L., Niewodniczanski, J., ORNL-IIC-10. 746 . . (1967).

Rulikowska. E.. Ibid.. 944. (492) Ostrowski, K. W., Jelen, K.,

(493) Padden; T.’ R., Burton, R., Camp- bell, C. E., U.S. At. Energy Comm.,

(494) Park, F. R., Bunch, T. E., Mas- salski, T. D., Geochim. Cosmochim.

WAPD-TM-644 (1967).

Acta, 30,399 (1966). (495) Parrish, W., Ed., “X-Ray and Elec-

tron hlethods of Analysis,” Plenum Press, N. Y., 1968.

(496) Pasztor, L. C., Hines, C. R., ANAL. CHEM., 39,92R (1967).

(497) Pavlinskii, 0. V., Losev, N. F., Makov, V. M., Zavodsk. Lab., 31, 1334 (1965).

(498) Pawlitschek, W., Wright, P. W., Z. Instrumentenk., 74, 248 (1966).

(499) Peter, G., Tuchscheerer, T., 2. Anal . Chem., 220,351 (1966).

(500) Peterson, O., Zem-Kalk-Gips, 20, 61 (1967).

(501) Philibert, J., Penot, D., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 365.

(502) Philibert, J., Weinryb, E., Mikro- chim. Acta, 1965,456.

(503) Philibert, J., Weinryb, E., Ancey, M., Metallurgia, 72,203 (1965).

(504) Pick, H. H., Bingham, E. R., Jr., U S . Patent 3,259,743 (1966).

(505) Pillay, .K. K. S., Ph.D. Thesis, Pennsylvania State Univ., University Park, Pa., Dec. 1965.

(506) Pinheiro, M. V. R. V., Revta Port. Quim., 7,193 (1965).

(507) Pivovarov, A. V., Zavodsk. Lab., 31,1339 (1965) (Eng. Ed.).

(508) Plaksin, I. K., Xikitin, F. V., Ibid., p 1829.

(509) Poole, D. hl., Bull . Inst . Metals, 8,51 (1966).

(510) Poole, D. M., Seminar on Electron Probe hlicroanalysis, Natl. Bur. Stds., Gaithersburg, hld., June 1967.

(511) Pope, D., Moss, R. L., Corros. Sci.. 5.773 (1965).

(512) ’PGtts, H. R.,‘Wear, 9,228 (1966). (513) Prokopovich, S. A., McCartney,

E. R., Analyst, 92,253 (1967). (514) Pruess, L. E., Bugenis, C., Tooth-

acker. W.. AEC COO-1239-1. March 1966.’ ‘

(515) Pruess, L. E., Collins, H., Artman, C., Bugenis, C., AEC TID-22361 Pt. 1 (1966).

(516) Puschel, R., Mikrochim. Acta, 4, 770 (1965).

(517) Ranzetta, G. 5’. T., Scott, V. D., Brzt. J . Appl . Phys., 18, 1403 (1967).

(518) Ranzetta, G. V. T., Scott, V. D., J . Sca. Instr., 43 816 (1966).

(519) Ranzetta, b. V. T., Scott, V. D., Metals and Materzals, 1, 146 (1967).

(520) Ranzetta, G. V. T., Scott, V. D., U.K. At. Energy Auth. AWRE 0-28/67 (1967).

(521) Ranaetta, G. V. T., Scott, V. D., “X-Ray Optics and hlicroanalysis,” Hermann, Paris, 1966, p 254.

(522) Rapperport, E. J., 2nd Natl. Conf. on Electron Microprobe Analysis, Bos- ton, Mass., 1967.

(523) Reed, S. J. B., Brzt. J . A p p l . Phys., 16,913 (1965).

(524) Reed, S. J. B., “X-Ray Optics and hlicroanalysis,” Hermann, Paris, 1966, p 339.

(525) Reed, S. J. B., Mason, P. K., 2nd Natl. Conf. on Electron Microprobe Analysis, Boston, Mass., 1967.

(526) Regis, A. J., Proc. Natzonal In- cznerator Conj. (1966), p 195, ASME.

(527) Reid, A. ?*I., Cohen, A. J., Geo- chzm. Cosmocham. Acta, 31, 661 (1967).

(528) Rekhkolainen, G. I., Zavodsk. Lab.,

(529) Rhodes, J. R., AERE R 4457 (1963). (530) Rhodes. J. R., Analust, 91. 683

32,191 (1966) (Eng. Ed.).

- . . . (1966). ‘

(531) Rhodes, J. R., British Patent 1,065,918 (1967).

(532) Ibid., 1,065,919. (533) Rhodes, J. R., ORNL-IIC-10, 442

(1967). (534) Ibid., p 843. (535) Rhodes, J. R., Daglish, J. G.,

Clayton, C. G., STI/PUB/112, 447 (1966).

(536)-Rhodes, J. R., Packer, T. W.,

(537) Ribbe, P. H., Smith, J. V.,

(538) Rice. R. W.. Racus. R. C.. J .

Boyce, I. S., Ibid., p 127.

J . Geol., 74,217 (1966).

mins, R., Ibid., 203,995 (1965). ’

(541) Riedl, F., Mikrochim. Acta, Suppl . 1 . 186(1966).

(542) Ri’gdon,’L. P., UCRL 14879 (1966). (543) R h o , F. E., Diffusion of Electro-

plated Couples. Ph.D. Thesis, Univ. of Cincinnati (1964).

(544) Robin, G., Darigny, E., STI/PUB/ 112.157 (1966).

(545) ’Rockert, ’H. 0. E., Rosengren, B. H. O., “X-Ray Optics and hlicro- analysis,’’ Hermann, Paris, 1966, p 650.

(546) Rolls, R., Bray, H. J., J . Inst . Metals, 95, 8 (1967).

(547) Rosendahl, F., Z . Anal . Chem., 225.213 (1967).

(548) ‘Ross; P: A., J . Opt. SOC. Am., 16, 433 (June 1928).

(549) Rosser, H., Boyle, A., Stewart, A. D. G., Arch. Oral. Biol., 12. 431 . . (1967).

2. Anal . Chem.. 213. 173 11965). (550) Rothe, G., Koster-Pflugmacher, A.,

(551) Sakai, E.,’ Malm, ‘H. L., A p p l . Physics Letters, 10,268 (1967).

(552) Salem, S. I., Zarlingo, D. G., Phys. Rev., 155,7 (1967).

(553) Sanderson, B. S., Yeck, J. A., Advan. X - R a y Anal . , 10, 474 (1967).

(554) Sanford, P. W., Culhane, J . L., ORNL-IIC-10,376 (1967).

(555) Schierding, R. G., Fergason, L. A., U.S. At. Energy Comm., MCW 1502 __ (1966).

(556) Schippert, hl. A., Moll, S. H., Ogilvie, R. E., Anal . Chem., 39, 867 (1967). ~ ~ . - . , .

(557) Schmidt, Act’

‘5Wb

(5591

R. A., Keil, K., Geochim. a , 30,471 (1966). Schnell, E., Monatsch. Chem., 96,

2 (1965). ~ Schnopper, H. W., Shields, R. A.,

(560) Schwander, H., Mikrochim. Acta, > p l . 1,211 (1966). Scott, V. D., Metals and Materzals,

9 (1967). Scotti, V. G., Johnson, J. M.,

Cunnineham. R. T.. Advan. X - R a v

JPL TM 33 221 (Sept. 1965).

Anal . . 31411966). ’

(563) Sbribner,‘ B. F., ed., Xatl. Bur. Std., Tech. Note 401 (1966).

(564) Ibid., 272 (1965). (565) Seibel, G., Traon Le, J. Y., Rev.

Met., 61, 342 (1964); Eng. Translation avail. as BISI 4054 (1965).

(566) Sellers, B., A E C Report NYO 3491 ‘ 1 (January 1966). (567) Sellers. B.. Kilson. H. H.. PaDado-

~ poulos, J.,’ORNL-IIC-10, 576’(1967). (568) Senftle, F. E., Tanner, A. B.,

ORNL-IIC-10.503 11967). I \

(569) Shappirio, H. A., Advan. X - R a y Anal . , 9,304 (1966).

(570) Shappirio, J. R., Tauber, A., Savage, R. O., Mat . Res. Bull., 2, 101 (1967).

(571) Shenbercc. C.. Gilat. J.. Finston. ‘ H.‘L., ANALPCHEA’L, 39,73O(i967). ‘ (572) Shequen, W. G., Smallbone, A. H.,

(573) Shibuva, K.. Takeshita, R l . , Sato, ARL Newsletter 19, 3 and 4 (1966).

’ K.‘, Tajima,’ M.’, Kitagawa, I.,‘ Tetsu To Hagane, 52,571 (1966).

(574) Shibuya, Y., Sishiyama, E., Yan- agase, K., J a p a n Analyst, 16,123 (1967).

(575) Shimiau, R., Murata, K., Shinoda, G., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 127.

(576) Shimiau, R., Shinoda, G., J a p a n J . A p l . Phys., 4,543 (1965).

(577) ihinoda,. G., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966,

(578) Shiokawa, J., Shin-Ike, T., Adachi, G., Ishino, T., J . Chem. SOC. Japan, 87.131 (1966).

p 97.

(579j Shiiaiwa,’ T., Fujino, N., Sumitomo Met., 18, 509 (1966).

(580) Short, M. A,, Ruscoe, 31. J. H., Advan. A’-Ray Anal . , 10, 520 (1967).

(581) Sieabahn, K., “Abha, Beta, and Gamma Ray Spectroscopy,” 2,’ No. Holland Publ. Co.. Amsterdam. 1965.

(582) Siemes, H., Z. Anal . C h e k , 199,

(583) Singer, S., J . A p p l . Phys., 38, 2897 321 (1964).

i 1 467) \ - - ” . ,. (584) Smaeunova, A. Y., Stakheeva,

S. A., Lipskaya, V. I., Zavodsk. Lab., 32,1637 (1966) (Eng. Ed.).

(585) Smagunova, A. X., Stakheeva, S. A., Losev, S. F., Zavodsk. Lab., 32,1314 (1966) (Eng. Ed.).

(586) Smallbone, A. H., Rock Products, p 60, Dec. 1965.

(587) Smith, J. V., J . Geol., 73, 830 il9fi.i\. ,----,

(588) Ibid., 74, l(1966). (589) Ibid., p 463. (590) Smith, J. V., Ribbe, P. H., Ibid., p

147 (56ij‘Smith, J. V., Stenstrom, R. G.,

Ibid., 73,627 (1965). (592) Smuts, J., Plug, C., Niekerk, J.

Van, J . S. African Inst . Mining and Met . , April 1967, p 462.

(593) Snyman, G. C., Intern. J . A p p l . Radiation Isotopes, 18, 243 (1967).

(594) Sobolevskaya, G. D., Ioffe, Y. K., Nikolaenko. G. 11.. Zavodsk. Lab.. 31, 1766 (1965) (Eng. Ed.).

(595) Solov’ev, A. M., Toporkov, S. A., Zayodsk. Lab., 32, 216 (1966) (Eng. Bd.).

(596) Sommerville, J. L., Ed., “The Iso- tope Index 1967,” Scientific Equipment Co., Indianapolis, Ind., 1967.

(597) Spano, E. F., Green, T. E., ANAL. CHEXI., 38,1341 (1966).

(598) Sparks, C. J., Jr., Increased X-Ray Intensities Using Graphite as a Mono- chromator, presented a t American Crystallographic Assoc. Meeting, Min- neapolis, JIinn., August 20-25, 1967.

(599) Speidel, I). H., i ldvan. X - R a y Anal . , 9, 259 (1966).

(600) Ibid., 10,534 (1967). (601) Spielberg, S., Rev. Sci. Instr.,

37,1268 (1966). (602) Ibad., 38,291 (1967). (603) Spielberg, N., 2nd Xatl. Conf. on

Electron Microprobe Analysis, Boston, Mass., 1967.

(604) Spielberg, N., Abowita, G., ANAL. CHEU., 38,200 (1966).

(605) Springer, G., Jahrbuch F . Xaner- dogie Monujshejte, 4, 113 (1966).

(606) Springer, G., Jfzkrochzm. Acta, 1966,587.

(607) Springer, G., “);-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 296.

(608) Squirrell, D. ,C . hI., Proc. SAC Conference, Nottingham, p 132, \V. Heffer and Sons Ltd., Cambridge, England.

374 R ANALYTICAL CHEMISTRY

Page 30: X-ray absorption and emission

(609) Standage, A. E., Gani, M. S., .I. .4?)1. Permi. Soc.. 50. 101 (1967).

(610) Starnes, P: E‘., Clark; J. \V. G., STI/PUB/112,243 (1966).

(611) Sterk, A. A, , ildvan. X-Ray Anal., 9,410 (1966).

(612) Sterk, A. A, , Marks, C., Saylor, M-. P.. Advan. X-Raw Anal.. 10. 399

. I

(1967): (613) Stobbs, J. J., Pearce, R. J., Whittle,

I., Trans. M e t . SOC., AIME, 233, 1676 i 196.5) ,- - - /

(614) Stoddart, H. A., Dowden, W. A., U.K. At. Energv Auth., AERE BIB 136 Parts I and If (1966).

(615) Stoeppler, XI., Wiesner, L., Kuhn, W., STI/PUB/112,147 (1966).

(616) Stone, I. C., Jr., Rayburn, K. A., ANAL. CHEM., 39,356 (1967).

(617) Strachura, S. J., Cooper, L., Ad- van. X-Ray Anal., 10, 422 (1967).

(618) Stulov, B. A., Lagutov, G. B., Panchuk, P. A., Zavodsk. Lab., 32, 1413 (1966) (Eng. Ed.).

(619) Swindells, N., J . Inst. Metals, 95, 316 (1967).

(620) Swoboda, K., Malissa, H., Mikro- chim. Acta, 1965,531.

(621) Taddeucci, A,, Barbieri, M., Met. Ital., 8,281 (1966).

(622) Tanemura, T., Japan. J . A p p l . Physics 5,51 (Jan. 1966).

(623) Taylor, A., Advan. X-Ray Anal. 9,194 (1966).

(624) Taylor, B. L., Proc. SAC Confer- ence, Nottingham, p 81 (1965), W. Heffer and Sons Ltd., Cambridge, England.

(625) Taylor. T. A., ANAL. CHEM.. 39, . . ~ 405 (19”67).’ (626) Taylor, T. A., M.Sc. Thesis, Stan-

ford University, Stanford, Calif. (1965). (627) Terrier, P., Capitant, M., “X-Ray

Optics and hlicroanalysis,” Hermann, Paris, 1966,622.

(628) Terziev, G., Am. Mineralogist, 51,29 (1966).

(629) Theisen. R.. Mikrochim. Acta, ‘ Suppl. 1 , 129 (1966). (630) Thejsen, R., “Quantitative Elec-

tron RIicroprobe Analysis,” Springer- Verlag, New York, ft965.

(631) Thiesen, R., X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 224.

(632) Thiesen, R., Vollath, D., “Tables of X-Ray Mass Attenuation Coef- ficients,” Verlag Stahleisen, Dusseldorf, 1967.

(633) Tolmie, R. W., ORNL-IIC-10, 817 (1967).

(634) Tousimis, A. J., Am. J . Med. Electronics, 5, 15 (1966).

(635) Toussaint, C. J., Vos, G., ANAL. CHES., 38,711 (1966).

(636) Trillat, J. J., h’ucleus (Paris), 7, 423 (1966).

(637) Trombka, J. I., Adler, I., Sch- madebeck, R., Lamothe, R., NASA X 641 66 344 (August 1966).

(638) Trost, A., STI/PUB/llZ, 435( 1966). (639) Tuchscheerer, T., 2. Anal. Chem.,

207,1(1965). (640) ‘Turkevich, A., Knolle, K., Emmert,

R. A., Anderson, W. A., Patterson, J. H., Rev. Sci. Instr., 37, 1681 (1966).

(641) Uchida, K., Tominaga, H., Im- amura, H., STI/PUB/llZ, 113 (1966).

(642) Ullrich, H. J., Phys. Status Solidi, 20, K113 (1967).

(643) Umeno, M., Gennai, N., Shinoda, G., 2nd Natl. Conf. on Electron Micro- probe Analysis, Boston, Mass., 1967.

(644) Umeno, M., Kawabe, H., Shinoda, G., Adoan. X-Ray Anal., 9, 23 (1966).

(645) Umeno, hl., Kawabe,,H., Shinoda, G., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 354.

(646) Vanden Heuvel, R. C., Methods of Soil Analysis N o . 9, p 771, American Societv of Anonomv. 1965.

(647) Varshneya, A.*K., Cooper, A. R., Cable, M., J . Appl. Phys., 37, 2199 (1966).

(648) Vasichev, B. S., Zavodsk. Lab., 31,1458 (1965) (Eng. Ed.).

(649) Vasichev, B. N., Zavodsk. Lab., 32,248 (1966) (Eng. Ed.).

(650) Vasichev, B.-N, , Der Schvants, G. V., Larichev, G. G., Rachkov, V. P., Prib. Tehk. Eksp., 11,176 (1966).

(651) Vieth, D. -L., Yakowitz, H., 2nd Natl. Conf. on Electron Probe Micro- analysis, Boston, Mass., 1967.

(652) Vieth, D. L., Yakowitz, H., Rev. Sci. Instr., 37,206 (1966).

(653) Vignes, A., Ded, G., 2nd Natl. Conf. Electron Microprobe Analysis, Boston, Mass., 1967.

(654) Vogel, R. S., Fergason, L. A., Rev. Sci. Instr., 37,939 (1966).

(655) Vos, G., European At. Commun., EUR 2951 (1966).

(656) Wagner, J. C., Bicknese, E. H., Bryan, F. R., Appl. Spectry., 21, 176 (1967).

(657) Wagner, J. C., Bryan, F. R., Advan. X-Ray Anal., 9,528(1966).

(658) Wagner, J. C., Violante, E. J., Appl. Spectry., 19, 195 (1965).

(659) Walker, G., Advan. X-Ray Anal., 9,504 (1966).

(660) Walter, L. S., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 615.

(661) Wardell, I. R. M., Ibid., p 463. (662) Warnaars, F. W., 2nd Natl. Conf.

on Electron Microprobe Analysis, Bos- ton, Mass., 1967.

(663) Watanabe, H., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966,

(664) Watt, J. S., AAEC/TM226-Sup- p 73.

plement 1 (1965). (665) Watt, J. S., Intern. J . A p p l .

Radzatzon Isotopes, 18, 383 (1967).

(666) Watt, J. S., ORNL-IIC-10, 663 (1967).

(667) Weinryb, E., Hourlier, P., Chim. Anal. (Paris), 48,219 (1966).

(668) White, E. W., Ph.D. Thesis, Pennsylvania State Univ., University Park, Pa., 1965.

(669) White, E. W., McKinstry, H. A., Advan. X-Ray Anal., 9,376 (1966).

(670) Whittaker, A., Green, G., Garnett, J. E., STU/PUB/112,271(1966).

(671) Whittle, D. P., Wood, G. C., Cor- ros. Sci., 6 , 397 (1966).

(672) Wilbur, D. W., UCRL 14379 (1965). (673) Wilbur, D. W., Gofman, J. W.,

Advan. X-Ray Anal., 9, 354 (1966). (674) Rilde, W., z. Chem., 7, 6 (1967). (678) Williams, K. L., Am. Mineralogist,

52,475 (1967). (676) Wilson, R. S., Forsyth, P. J. E.,

J . Inst. Metals, 94,s (1966). (677) Wittman, A., Bourdieu, J. M.,

Jorre, D., Rev. Met,., 63, 529 (1966), Eng. translation avail. as BISI 5068.

(678) Wittry, D. B., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 168.

(679) Wittry, D. B., Andersen, C. A,, 2nd Satl. Conf. on Electron Micro- probe Analysis, Boston, Mass., 1967.

(680) Wittry, D. B., I’ancouvering, A., J . Sci. Instr., 44,294 (1967).

(681) Wlotzka, F., 2. Anal. Chem., 215, 81 (1966).

(682) Wonsidler, G. J., Sprague, R. S., Ann. Chim. Acta, 31,51 (1964).

(683) Wray, L. W., AECL 2526 11965). (684) Wright, J. B., Am. Mineralogist,

(685) Wright, J. B., Lovering, J. F.,

(686) Wybenga, F. T., Appl. Spectry.,

52, 524 (1967).

M i n e d . Mag., 35,604 (1965).

19.193 (1965). (687); Yakowit;, H., J . ~ p p i . ~ h y s . , 37,

4455 (1966). (688) Yakowitz, H., Vieth, D. L., J .

Res. il’atl. Bur. Stds., 69C. 214 (1965). I ,

(689) Yakowitz, H., Vieth, D. L., Hein- rich, K. F. J., Michaelis, R. E., Ad- van. X-Rav Anal., 9,289 119661. . ,

(690) Yates,” A. hI., X-Ray Fluorescence Analysis of Chrondritic Meteorites, Ph.D. Thesis, Arizona State Univ., Tempe, -4riz. (1966).

(691) Yee, K. W., Deslattes, R. D., Rev. Sci. Instr., 38, 637 (1967).

(692) Zeitz, L., X-Ray Fluorescence Analysis in Biological Specimens, pres. a t NIH Symposium on Research Methods, Bethesda, Md. (1966).

(693) Zeitz, L., Andersen, C. A., “X-Ray Optics and Microanalysis,” Hermann, Paris, 1966, p 691.

(694) Zeller, C., Reithler, J. C., Bolfa, J., Labour, F., C.R. Acad. Sci. Paris Ser. C , 263, 1050 (1966).

(695) Ziebold, T. O., ASAL. CHEM., 39, 858 (1967).

VOL. 40, NO. 5, APRIL 1968 375 R