XENITH PRODUCT LINE INSTALLATION MANUAL

VERSION 6.0 101-0008-014

Phone: 734 / 913-8080Fax: 734 / 913-8088

Xitron, Inc.781 Avis DriveSuite 200Ann Arbor, Michigan 48108USA

Page 2: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

P

RELIMINARIES

IMPORTANT: Xitron products are so designed and constructed as to be safe without risk to health when properly used (in accordance with the supplied documentation) and when the safety precautions con-tained in this document are fully observed.

This product must not be copied without prior written authorization and is subject to change without no-tice. For further information, contact the Product Manager for Workflow Products at the address given on the front page of this manual.

The manual was written and illustrated using the best possible information at the time of publication. Any differences between the manual and equipment reflect improvements introduced after publication of the manual. Changes, technical inaccuracies and typographic errors will be corrected in subsequent editions. As part of our policy of continuous improvement, we reserve the right to alter design and spec-ifications without further notice.

WARNING: All precautions mentioned in this document must be strictly observed at all times. Personnel must read the contents of any documentation supplied and used with this product BEFORE commencing any work with equipment described in this docu-ment.

NOTE: Measured noise level for this product is less than 65 dBa.

CAUTION: Xitron Inc. cannot be held responsible for any loss or damage to customer s data by unauthorised third parties accessing the system. In the event that Xitron becomes aware of any computer virus which will or is likely to affect the system it will take rea-sonable steps to bring this to the attention of customers but advices customers to take their own precautions aganist unauthorised access.

TRADEMARKS and COPYRIGHT: Xitron and Xenith are trademarks of Xitron, Inc. that may be regis-tered in certain jurisdictions; Adobe, Accurate, PageMaker, Illustrator, PostScript, Photoshop and Type Manager are trademarks of Adobe Systems Inc. that may be registered in certain jurisdictions; Windows and Windows NT are trademarks of Microsoft Corporation that may be registered in ceratin jurisdictions; All other company names, products or brand names are trademarks of their respective holders.

Page 3: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

TABLE OF CONTENTS

Chapter 1 Introduction

About This Guide..................................................................................................... 1-1

Before you Begin ..................................................................................................... 1-1

Chapter 2 Raster Blaster Installation

Installing Raster Blaster ......................................................................................... 2-1Log in as Administrator ........................................................................................ 2-1

Identify Program Folder ....................................................................................... 2-2

Select Output Device Files................................................................................... 2-2

Deselect Web Browser Files ................................................................................ 2-3

Start Copying Files................................................................................................ 2-3

Chapter 3 Device Setup

Creating New Devices ............................................................................................ 3-1

Device Configuration Tabs ................................................................................... 3-2Device Tab ............................................................................................................. 3-2

Settings Tab............................................................................................................ 3-3

Exposure Text Box ............................................................................................. 3-3Cassette Menu..................................................................................................... 3-3Resolution Menus ............................................................................................... 3-3

Options Tab ............................................................................................................ 3-4

Supply Tab ............................................................................................................. 3-5

Takeup Tab............................................................................................................. 3-5

Creating a Second Device .................................................................................... 3-6

i

Page 4: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

P

RELIMINARIES

Chapter 4 Queue Setup

Configuring Queue Folders ................................................................................... 4-1Share the RBQueues Folder ................................................................................. 4-2

Map the RBQueue Drive ...................................................................................... 4-3

Configuring New Queues ...................................................................................... 4-4

Chapter 5 Xenith Installation

Installing Xenith ....................................................................................................... 5-1Log in as Administrator ........................................................................................ 5-1

Select Bundles........................................................................................................ 5-2

Confirm Component Selection ............................................................................ 5-3

Start Copying Files ................................................................................................ 5-4

Installing Licenses ................................................................................................... 5-6

Chapter 6 Device Setup

Device Utilities ......................................................................................................... 6-1

Creating a New Device........................................................................................... 6-1

Remove the Raster Blaster Device...................................................................... 6-3

Chapter 7 Remote Clients

Starting Xenith .......................................................................................................... 7-1

Installing the Macintosh Clients........................................................................... 7-2

Starting the Macintosh Clients ............................................................................. 7-4

Configuring the Macintosh Viewer..................................................................... 7-4

Installing PC Clients................................................................................................ 7-6

Starting the PC Clients............................................................................................ 7-8

Configuring the PC Viewer................................................................................... 7-9

ii

Page 5: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

X

ENITH

I

NSTALLATION

Chapter 8 Calibration Manager

Preferences................................................................................................................. 8-1

Media........................................................................................................................... 8-2

Cassettes ..................................................................................................................... 8-4

Screen Sets ................................................................................................................. 8-5

Recorders and Proofers........................................................................................... 8-8

Calibration.................................................................................................................. 8-9

Chapter 9 Rip Manager

Preferences................................................................................................................. 9-1

Job Tickets ................................................................................................................. 9-2Creating a New Job Ticket ................................................................................... 9-2

Setting Job Priority................................................................................................ 9-3

Setting Input Parameters....................................................................................... 9-4

Setting RIP Parameters ......................................................................................... 9-6

Output Tile ............................................................................................................. 9-7

Page Setup Parameters ........................................................................................ 9-8Screening Parameters.......................................................................................... 9-9Output Parameters............................................................................................... 9-10

Copying a Job Ticket ............................................................................................ 9-12

Chapter 10 Printing a Test Job

Raster Blaster Test Job ........................................................................................... 10-1

Xenith Test Job......................................................................................................... 10-2

Appendix A Setting Up a Slave PC

Setting Up the Slave PC......................................................................................... A-1

Installing Xenith Software On the Slave PC .................................................... A-2

iii

Page 6: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

P

RELIMINARIES

Adding a Slave with the Configuration Tool.................................................... A-6

Starting the Slave RIP............................................................................................. A-9

Using the Slave RIP................................................................................................. A-10

Appendix B System Elements

System Elements ...................................................................................................... B-1RIP Server............................................................................................................... B-1

Output...................................................................................................................... B-2

Input......................................................................................................................... B-2

Primer ...................................................................................................................... B-2

Adobe RIP .............................................................................................................. B-2

ROOMProof ........................................................................................................... B-2

File Importer........................................................................................................... B-3

Storage..................................................................................................................... B-3

Devices.................................................................................................................... B-3

Appendix C Defining Paths to Folders

Introduction................................................................................................................ C-1

Methods of Path Specification.............................................................................. C-1Drive Letter and Colon Method........................................................................... C-1

Universal Naming Convention Method.............................................................. C-2

Access by Multiple PCs ...................................................................................... C-2

Path Definition for Xenith Folders...................................................................... C-2

iv

Page 7: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

1 INTRODUCTION

About This GuideThe Xenith Product Line Installation Guide is meant as a companion to the Xenith Reference Manual. It will walk one through the installation and con-figuration of the Xenith, Xenith 4PDf or Xenith extreme as well as Raster Blaster. The Xenith Installation Guide is not meant to replace the Xenith or Raster Blaster Users Guides. Any questions about the configuration or oper-ation of either software product should be directed to the appropriate user guide.

NOTE: The Avantra 44 imagesetter will be used as an example throughout this guide. One should make appropriate substitutions for the specific output device being used with Xenith and Raster Blaster.

Before you BeginXenith is designed to run on a PC running Windows 2000 or 2003 Server. It should always be installed on a different hard drive from the operating sys-tem. The Raster Blaster software will be installed on a separate PC running Windows 2000 or XP. it may also be installed on the same system as Xenith as long is it is on a separate hard drive from Xenith. Xenith may be con-

XENITH INSTALLATION Xitron 1-1

Page 8: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 1:

trolled from any number of PC or Macintosh workstations connected to the Xenith server via a TCP/IP connection.

Do not install other applications or utilities beyond those needed for system operation in the Xenith PC. Uneeded utilities and applications may interfere with the functioning of one or both programs.

Before beginning installation the following tasks should be completed:

Windows 2000 or 2003 server with current service packs should be installed on the Xenith PC.

Windows 2000 or XP with current service packs should be installed on the Raster Blaster PC if running on a separate platform.

TCP/IP and services for Macintosh should be installed on the Xenith PC.

TCP/IP should be installed on the Raster Blaster PC or other TIFF catcher.

A static IP address should be assigned to the Xenith server.

Connectivity from the Xenith PC to the network should be established using the PING command from the command prompt. At the command prompt type:ping<space>IP address of network server<enter>If connectivity is established, a reply will be made by the network server. If connectivity has not been established a Request Timed Out error will be received.

Connectivity from the Raster Blaster or TIFF catcher to the Xenith server should be established using the PING command from the com-mand prompt. At the command prompt type:ping<space>IP address of Xenith server<enter>If connectivity is established, a reply will be made by the network server. If connectivity has not been established a Request Timed Out error will be received.

Both the Xenith and Raster Blaster dongle must be installed on their respective PCs.

The Xitron card set should be installed in Raster Blaster and connected to the output device. This task will vary depending on the device being used. Refer to the plug-in manual for the device being used for more spe-cific information.

1-2 Xitron XENITH INSTALLATION

Page 9: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

2RASTER BLASTER

INSTALLATION

Installing Raster BlasterThe first step in setting up th e Xenith PC is the installation of the Raster Blaster software. If you will not be using Raster Blaster with Xenith, please skip ahead to Chapter 5. Raster Blaster is Xitron s 1-bit Tiff imager soft-ware and will be used to drive the film or platesetter. Raster Blaster must be installed on a separate hard drive than the Windows system files and the Xenith RIP. The following steps will walk one through Raster Blaster instal-lation:

Log in as Administrator1. Log in to Windows as a user with administrator privileges.

2. Insert the Raster Blaster CD in the PC.

3. The installation program checks to see if all the necessary system files are in place on the computer. If all the system files are there, the installer will switch to the Welcome screen. If the installer finds that the system files need to be updated, it will automatically perform this procedure. The installer will then ask that the PC be rebooted. When the PC has fin-ished rebooting, restart installation by running the setup.exe file located in the Xitron folder on the Raster Blaster CD.

XENITH INSTALLATION Xitron 2-1

Page 10: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 2:

4. To start installing Raster Blaster, click Install.

5. At the Welcome screen click Next.

Identify Program Folder6. Enter the name and location of the folder in which Raster Blaster will be

installed. The browse button may be used to locate or create a folder on the local hard drive. Once a folder has been defined, click Next.

Select Output Device Files7. On the Select Components screen, highlight the line that says:

Output Device Files - Select Output DevRemove the check mark from the box to the left.

8. Click Change. The Select Sub-components dialog box appears, contain-ing a menu of Output Plugins.

2-2 Xitron XENITH INSTALLATION

Page 11: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Raster Blaster Installation

9. Select Avantra 44 from the list of sub-components.

NOTE: The Avantra 44 will be used in all examples throughout this install guide. You should select the appropriate plugin for your imagesetter.

10. Click continue to exit the select sub-component screen.

Deselect Web Browser Files11. Remove the check mark from the line that says:

Web Browser Files The web browser will not be used with the Xenith RIP.

12. Click Next to continue and select a program folder.

Start Copying Files13. Click Next to bring up the Start Copying Files screen. This will display

the current install directory and the program folder. If these are accept-able click Next to begin copying files.

14. Once finished Raster Blaster will display the InstallShield Wizard Com-plete window. Click Finish to complete the installation and restart the computer.

XENITH INSTALLATION Xitron 2-3

Page 12: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 2:

2-4 Xitron XENITH INSTALLATION

Page 13: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

3DEVICE SETUP

Creating New DevicesBefore one can begin using Raster Blaster an output device must be config-ured. The following steps will outline the procedure of device setup and walk the reader through the creation of two devices.

NOTE: The example of an Avantra 44 at 1200 and 2400 DPI will be used throughout the setup and installation of Raster Blaster.

1. Open the Device Configuration dialog box by clicking on the File menu and choosing Configure Devices. The Device Configuration dialog box has up to five tabs that allow for configuration of devices and parameter sets (PSets). A different sub-set of tabs is involved in these two configu-ration tasks.

NOTE: If the PSets for a device are displayed in the Output Devices list, double-clicking on the device icon can hide them. If they are already hidden, double-click the device icon to display them. After adding a new PSet, all PSets for that device are displayed.

2. To configure a new device, click the New Device button.

3. The Add New Device dialog box appears.

4. From the Driver pop-up menu, select Agfa.

XENITH INSTALLATION Xitron 3-1

Page 14: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 3:

5. If a device with more than one type is chosen, the Type pop-up menu will become active. It lists the available device types that apply to the selected Driver.

6. From the Type pop-up menu select Avantra 44.

7. In the Name field, highlight Avantra 44-0 and change it to Avantra 44 2400 .

8. Most devices will have additional options that are configured using the Driver Config button. See the plugin manual for instructions on these additional configuration settings.

9. The Address text box and button are not used in this version of Raster Blaster.

10. Click O.K. to add the device. The new device appears in the Output Devices window of the Device Configuration dialog box.

Device Configuration TabsThe Device Configuration dialog box choices are divided into a series of five parameter tabs. Each tab is described below.

Device TabThe Device tab displays information about the selected device in the Output devices window.

The Max. Width field refers to the fast scan direction of the imager. The Max. Height field refers to the slow scan direction, if any. These values will be necessary for setting up the device in Xenith.

3-2 Xitron XENITH INSTALLATION

Page 15: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Device Setup

Settings TabThe Settings tab contains the following parameters:

Exposure Text BoxFor imager setters that allow Raster Blaster to control laser intensity, enter the desired intensity in Exposure. A value of zero will cause the imagesetter to use its last stored value.

Enter a value of zero.

NOTE: If the imagesetter already has a good exposure value it is recommended that a value of zero be used. This will help to avoid any potential problems with output.

Cassette MenuA new device will be created for each media size at each resolution. For this reason cassette 1 will always be used in the cassette menu.

Choose cassette 1.

Resolution MenusIt is important to remember that Raster Blaster is not a RIP. The 1-bit Tiff files it accepts as input have already been ripped, screened and trapped; therefore, Raster Blaster cannot re-purpose any of the data in the file. For this reason, the resolution of the device in Raster Blaster must be the same as the resolution of the incoming Tiff file from Xenith. If the imagesetter being

XENITH INSTALLATION Xitron 3-3

Page 16: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 3:

used supports multiple resolutions, it will be necessary to create multiple devices in Raster Blaster. One device is needed for each resolution that will be used.

Choose a resolution of 2400.

Options TabCheck the option for Override Job Resolution. All other options should be left unchecked. Xenith will handle these options.

3-4 Xitron XENITH INSTALLATION

Page 17: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Device Setup

Supply TabUse the supply tab to configure cassettes for the device. Follow the steps below to configure a cassette:

1. Select Cassette 1 from the list

2. In the Media Type field enter 30 inch film .

3. In the Media Width field enter a value of 30 .

4. Select Slot A and click the Add Cassette button. This will load cassette 1 in slot A.

The final two options in the Supply tab; Disable Media Tracking and Disable Cassette Tracking should be left on, as most recorders will handle these functions on their own.

Takeup TabIf an on-line processor is to be used with the output device, place a check mark in the Online Processor option at the bottom of the page. Otherwise all options should be left unchecked when using Xenith.

XENITH INSTALLATION Xitron 3-5

Page 18: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 3:

Click O.K. to save the device setup and exit.

Creating a Second DeviceThe steps below will outline the creation of a second device at 2400 DPI.

1. Click on the File menu and choose Configure Devices.

2. Click the New Device button.

3. The Add New Device dialog box appears.

4. From the Driver pop-up menu, select the Agfa.

5. From the Type pop-up menu select Avantra 44.

6. In the Name field type Avantra 44 1200 .

7. Click O.K..

8. Click on the Settings tab.

9. Enter an Exposure value of 0 .

10. Select cassette 1.

11. Choose a resolution of 1200.

12. Click on the Options tab.

13. Click the Override Job Resolution check box.

3-6 Xitron XENITH INSTALLATION

Page 19: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Device Setup

14. Click on the Supply tab.

15. Select Cassette 1 from the list

16. In the Media Type field enter 30 inch film .

17. In the Media Width field enter a value of 30 .

18. Select Slot A and click the Add Cassette button.

19. Click O.K. to save the device and exit.

XENITH INSTALLATION Xitron 3-7

Page 20: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 3:

3-8 Xitron XENITH INSTALLATION

Page 21: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

4QUEUE SETUP

Configuring Queue FoldersEach job to be output by Raster Blaster must be placed in a drop folder where Raster Blaster can pick up the file. These drop folders are known as Queues within Raster Blaster. Raster Blaster must have a unique queue for each output device. The two Avantra 44 devices created in Chapter 3 will require two Queues in Raster Blaster. It is suggested that all queue folders be created in Windows before the actual queues are created in Raster Blaster. It is also suggested that a master queue folder titled RBQueues be created in Windows. The device specific queues will be contained within the RBQueues folder. The following image shows the queue structure for a mul-tiple device setup in Raster Blaster:

XENITH INSTALLATION Xitron 4-1

Page 22: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 4:

Share the RBQueues FolderIt will be necessary to share the RBQueues folder from windows to allow the Xenith server to access the Raster Blaster queue folders. Follow the steps below to share the RBQueues folder in Windows NT:

1. Right click on the My Computer icon and choose explore.

2. Navigate to the \Raster Blaster\RBQueues folder.

3. Right click on the RBQueues folder and choose sharing.

4. On the Sharing tab of the RBQueues properties dialog box, select the option Share this folder.

5. The name RBQueues will appear in the Share name field.

6. Click O.K. to save your changes.

The RBQueues folder will now be accessible from the Xenith server.

It is recommended that the RBQueues folder be mapped as a network drive on the Xenith server.

4-2 Xitron XENITH INSTALLATION

Page 23: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Queue Setup

Map the RBQueue DriveFollow the steps below to map the RBQueue drive:

1. On the Xenith server, double click on the My Network Places icon.

2. Click on the Tools menu and choose Map Network Drive.

3. In the Drive drop down menu, choose the drive letter that will be associ-ated with the RBQueues folder.

4. Click the Browse button next to the Folder drop down menu.

5. 5. Navigate to the RBQueues folder.

6. Select the RBQueues folder and click O.K..

7. Click Finish to complete the process.

The RBQueues folder will now be available as a hard drive on the Xenith server. This will make sending files from Xenith to the queues in Raster Blaster quicker and easier.

XENITH INSTALLATION Xitron 4-3

Page 24: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 4:

Configuring New QueuesOnce the folders have been created in Windows they may be assigned as queues in Raster Blaster. Follow the steps below to create a new queue.

1. To configure new queues, click on the File menu and choose Configure Queue. The Configure Queue dialog box will appear.

NOTE: When this dialog box opens for the first time, a queue direc-tory called \PAGEBUFF\ appears in the Queue Folder pop-up menu. Leave this entry in the Queue Folder text box -- do not delete it. The PAGE-BUFF directory is the folder where jobs enter Raster Blaster and where Raster Blaster creates sub-folders for storing jobs either waiting to output or already output.

2. In the Megabytes of free disk space field, change the default value of 50 to 1000. This will force Raster Blaster to keep 1 gig of disk space free for file copying, temporary space and virtual memory.

4-4 Xitron XENITH INSTALLATION

Page 25: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

XENITH RIP 4-5

NOTE: The queue folders Raster Blaster monitors for incoming files are known as Monitor Points within the Configure Queue win-dow. For each queue folder created in windows there will be a cor-responding monitor point.

3. Click the Add Monitor button to add a monitor point.

4. Click the Browse button to the right of the Folder field and navigate to the Avantra 44 1200 folder.

Browse

5. Click O.K. to add the folder as a monitor point.

6. In the Device field select Avantra 44 1200.

7. Check the box for the Always use Device and PSet associated with Queue option.

8. All other options will be controlled from Xenith and should NOT be checked in Raster Blaster.

Page 26: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 4:

9. Click O.K. to save the monitor point.

10. Repeat steps 5 through 11 to add a monitor point for the Avantra 44 2400 device.

In addition to creating a queue folder for each output device, it is helpful to create a queue folder titled Calibrate. The Calibrate queue will be used to hold the calibration strips output by Xenith and will not have a monitor point in Raster Blaster. From the Calibrate folder the calibration strips will be cop-ied to the queue folder of the appropriate resolution. The function of the Cal-ibrate folder will be discussed further under Calibration on page 8-9.

4-6 Xitron XENITH INSTALLATION

Page 27: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

5XENITH INSTALLATION

Installing XenithThe following steps will outline the process of installing Xenith:

NOTE: The example of an Avantra 44 at 1200 and 2400 DPI will be used throughout the setup and installation of Xenith.

Log in as Administrator1. Log in to Windows as a user with administrator privileges.

2. Insert the Xenith CD in the PC.

3. The installation program checks to see if all the necessary system files are in place on the computer. If all the system files are there, the installer will switch to the Welcome screen. If the installer finds that the system files need to be updated, it will automatically perform this procedure. The installer will then ask that the PC be rebooted. When the PC has fin-ished rebooting, restart installation by running the setup.exe file located in the Xitron folder on the Xenith CD.

4. At the Welcome screen click Next.

5. Enter the name and location of the folder in which Xenith will be installed. The browse button may be used to locate or create a folder on the local hard drive. Once a folder has been defined, click Next.

XENITH INSTALLATION Xitron 5-1

Page 28: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 5:

Select Bundles6. Xenith will load the component installer and then display the Bundle

Selection screen. Of the available options, Xenith RIP and Extreme Components must be selected. In addtion, Xenith Extreme users should select Support for JDF . Other options such as Epson and HP proofers or the Adobe Acrobat in-RIP trapping plugin may also be cho-sen here. Click Next to continue.

7. At the Component Confirmation screen, Xenith will list the selected Bundles at the top and individual components at the bottom. Click Next to continue.

5-2 Xitron XENITH INSTALLATION

Page 29: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Xenith Installation

Confirm Component Selection8. The installer now asks the user to select the installation path.

It is important to install Xenith on the X drive! DO NOT install on the C drive.

9. Xenith now displays the Confirm window listing all components to be installed. Click O.K. to continue.

XENITH INSTALLATION Xitron 5-3

Page 30: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 5:

10. The check Install Paths lists the working directories Xenith will use after installation.

Start Copying Files11. Click O.K. to begin copying files. The component installer will now dis-

play a Progress window and begin copying files to the hard drive. Click-ing Cancel at any time will abort the installation process.

5-4 Xitron XENITH INSTALLATION

Page 31: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Xenith Installation

12. Once finished the Component installer will display the Completed win-dow and a list of the successfully installed components. Click O.K. to continue.

13. The Component Installer window will now be displayed. To finish installation click on the File menu and chose Exit.

XENITH INSTALLATION Xitron 5-5

Page 32: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 5:

14. Choose Yes to restart the computer.

Installing LicensesAll Xenith options installed on the PC must be licensed before they can be used. Follow the steps below to enter the license codes supplied with the Xenith software:

1. Launch the License Tool by clicking on the Start Menu in Windows and navigating to Programs\Xitron Xenith\License Tool.

2. Click on the Licenses tab.

3. Click the Add License button.

4. In the Enter License dialog box enter the first license code listed on the Xenith Dongle Pass Codes sheet.

5. Click O.K. to add the license.

6. Repeat steps 1 through 5 for each License on the Xenith Dongle Pass Codes sheet.

5-6 Xitron XENITH INSTALLATION

Page 33: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

6DEVICE SETUP

Device UtilitiesAll devices used in Xenith are created in the Device Utilities. To start the Device Utilities, click the Start button and navigate to Programs\Xitron Xenith\Device Utilities and click Start. This will bring up the Device Utili-ties program window.

NOTE: The Device Utilities program cannot be run while the Xenith RIP is running. As a result, the RIP must be exited if changes to a device become necessary.

Before beginning, it is a good idea to know the fast scan and slow scan dimensions of the output device and also the resolutions that will be used. These dimensions will be the Max Width and Max Height of the output device in Raster Blaster Alternatively, they can be found on the manufac-turer s website. See Device Tab on page 3-2.

Creating a New DeviceFollow the steps below to create a new device:

1. From the File menu select new, remote device.

2. In the Device name field type Avantra 44 .

3. From the drop down menu in the Device Type field choose TiffExport.

4. In the Unit of Measurement field select Inches.

XENITH INSTALLATION Xitron 6-1

Page 34: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 6:

5. Since Xenith outputs Tiff files to Raster Blaster, the Max Media Thick-ness, Media Type and Media Format fields will not be used. The default values will be acceptable for each.

Do not change these values for a TIFF device as it may cause problems later during the installation.

6. In the Fast Scan Size and Slow Scan Size fields enter the fast scan and slow scan dimensions of the output device. These settings are listed as the Max Width and Max Height of the output device in Raster Blaster. Enter a Fast Scan value of 44.5 and a Slow Scan value of 35.7.

7. The Orientation field controls the rotation and right read wrong read sta-tus of the Tiff file output by Xenith. Since many imagesetters and CTP devices function differently from one another it may be necessary to modify this value to get the best results. For more information on the Orientation settings please refer to the Xenith users guide included with the software.

8. The Rows Per Strip field determines how much data will be written to the Tiff file upon download to the Raster Blaster. For any Tiff Export device this should be set to 15. For all other devices the field will be set to 1 and disabled.

9. In the resolutions field, enter the resolutions to be used by this output device. Only values entered in the Device Utility will be available in the RIP. Multiple values should be separated by commas. Enter the values of 1200, 2400.

10. The Default Export Folder is the target destination for any file output from this device. It will also be the target destination for any calibration strip output using this device. Set the Default Export Folder to the Cali-brate folder in the RBQueues directory created in Configuring Queue Folders on page 4-1.

6-2 Xitron XENITH INSTALLATION

Page 35: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Device Setup

11. After all options have been set appropriately click O.K. to save the device.

12. From the File menu choose Exit to exit the Device utilities.

Remove the Raster Blaster DeviceThe default device, named Raster Blaster, is no longer needed. Deleting the device will remove it s media and cassette settings from Xenith and help to

XENITH INSTALLATION Xitron 6-3

Page 36: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 6:

keep the system clean. Follow the steps below to delete the Raster Blaster device:

1. Select the Raster Blaster device from the list in Device Utilities.

2. From the Device menu choose Delete.

3. Click O.K. at the prompt to remove the device from Xenith.

6-4 Xitron XENITH INSTALLATION

Page 37: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

7REMOTE CLIENTS

Customers have the ability to control all functions of Xenith from any PC or Macintosh work station on the network using Xenith s built in clients. This chapter will explain how to install the clients on a remote work station.

NOTE: Before remote clients can connect to Xenith, the RIP must be running.

Starting XenithFollow the steps below to start Xenith:

1. From the Start Menu in Windows, select:Start > Programs > Xitron Xenith > Start System

The Xitron Applications window will appear, displaying the system log and status of application processes:

XENITH INSTALLATION Xitron 7-1

Page 38: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 7:

2. The RIP Manager and Calibration Manager will start automatically when the RIP has started.

Installing the Macintosh ClientsFollow these steps to install the Macintosh clients:

1. Insert the CD labeled Xenith Macintosh Client Installer .

2. For OS X, simply drag the Xenith OS X Client folder to the hard drive.

3. For OS 9, Double-click the Xenith OS 9 Installer.

7-2 Xitron XENITH INSTALLATION

Page 39: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Remote Clients

4. Select the components desired from the dialog box:

XENITH INSTALLATION Xitron 7-3

Page 40: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 7:

Starting the Macintosh Clients

In order to run the Macintosh clients, the Xenith hard drive must be mounted using AppleTalk and TCP/IP must be enabled, set to Active and the Load Only When Needed option must be deselected.

To start a client on the Macintosh, double click its icon on the desktop.

At the login screen, enter the TCP/IP address of the Xenith server and click O.K..

Configuring the Macintosh ViewerIn order to run the Macintosh Viewer, the Xenith hard drive must be mounted using AppleTalk.

To launch the Viewer on the Macintosh, double click on its icon on the desk-top.

7-4 Xitron XENITH INSTALLATION

Page 41: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Remote Clients

Follow the steps below to configure the Viewer to work with the Xenith server:

1. Click on the Options menu and choose General.

2. In the General Options window select Remote Server under Environ-ment.

3. Under Remote Server Name enter the TCP/IP address or network identi-fication name of the Xenith server followed by a space and the Macin-tosh share name of the Xenith drive in the {} brackets.

NOTE: The network identification name will only work if there is a DNS server on the network or the host file supplied with the Xenith Clients is used.

4. Under the Default Image Open heading change the Zoom from 1 to 0.

5. Under Point Sample Sizes change the Bi-level images from 48 to 4.

XENITH INSTALLATION Xitron 7-5

Page 42: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 7:

6. Click O.K. to save and exit.

Installing PC ClientsThe Xenith clients will run on any PC running Windows 98 or higher. It is a good idea to know the TCP/IP address of the Xenith server before begin-ning. Follow the steps below to install the Xenith Light clients on a PC work station:

1. Place the Xenith CD in the PC.

7-6 Xitron XENITH INSTALLATION

Page 43: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Remote Clients

2. The installation program checks to see if all the necessary system files are in place on the computer. If all the system files are there, the installer will switch to the Welcome screen. If the installer finds that the system files need to be updated, it will automatically perform this procedure. The installer will then ask that the PC be rebooted. When the PC has fin-ished rebooting, restart installation by running the setup.exe file located in the Xitron folder on the Xenith CD.

3. At the Welcome screen click Next.

4. Enter the name and location of the folder in which Xenith will be installed. The browse button may be used to locate or create a folder on the local hard drive. Once a folder has been defined, click Next.

5. Xenith will load the component installer and then display the Bundle Selection screen.

.3Select the Windows GUI Clients option and click Next.

6. Click Next at the Component Confirmation screen

7. Xenith now displays the Confirm window listing all components to be installed. Click O.K. to continue.

XENITH INSTALLATION Xitron 7-7

Page 44: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 7:

8. The component installer will now display a Progress window and begin copying files to the hard drive. Clicking Cancel at any time will abort the installation process.

9. Once finished the Component installer will display the Completed win-dow and a list of the successfully installed components. Click O.K. to continue.

10. The Component Installer window will now be displayed. To finish installation click on the File menu and chose Exit.

11. Choose Yes to restart the computer.

Starting the PC ClientsTo start either the RIP Manager or Calibration Manager, click on the Start menu, navigate to Programs\Xitron Xenith\Clients and click on the RIP Manager or Calibration manager icons.

At the login screen, enter the TCP/IP address of the Xenith server and click O.K..

7-8 Xitron XENITH INSTALLATION

Page 45: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Remote Clients

Configuring the PC ViewerTo launch the Viewer application click on the Start menu, navigate to Pro-grams\Xitron Xenith and choose Viewer. Follow the steps below to config-ure the Viewer:

1. Click on the Options menu and choose General.

2. In the General Options window select Remote Server under Environ-ment.

3. Under Remote Server Name enter the TCP/IP address or network identi-fication name of the Xenith server.

4. Under the Default Image Open heading change the Zoom from 1 to 0.

5. Under Point Sample Sizes change the Bi-level images from 48 to 24.

XENITH INSTALLATION Xitron 7-9

Page 46: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 7:

6. Click O.K. to save changes.

7-10 Xitron XENITH INSTALLATION

Page 47: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

8CALIBRATION MANAGER

Switch to the Calibration Manager for the instructions in this chapter. If the Calibration Manger is not open it can be started by double-clicking its icon on the desktop.

Preferences

Open the preferences by clicking on the Edit menu and choosing Pref-erences.

On the General tab, select inches as the unit of measurement. Click O.K. to close the preferences.

XENITH INSTALLATION Xitron 8-1

Page 48: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

MediaOpen the Media window by clicking the View menu and choosing Media.

Because Xenith will be used to output a Tiff image, there is no real media used. However, Xenith requires at least one media to be loaded in each device created in Recorder Utilities. Regardless of how many media sizes are actually used in the output device, only one media need be created in Xenith. This media will reflect the largest possible output size for the device. Raster Blaster will handle the actual control of media sizes for output.

1. Click the New Media button in the Media window.

New

2. In the Name field type Avantra 44 .

3. In the Media Type field select TiffExport Default Media Type.

4. In the Width field enter the width of the largest media size used for out-put.

5. In the Length field enter 100 .

8-2 Xitron XENITH INSTALLATION

Page 49: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Calibration Manager

6. Click the O.K. button in the Media window and at both verification warnings to create the new media.

NOTE: The Length field refers to the remaining media in the output device, not to the maximum length the output device can image. Because Xenith outputs a Tiff image, there is no actual media and the setting will be ignored.

XENITH INSTALLATION Xitron 8-3

Page 50: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

CassettesOpen the Cassette window by clicking the View menu and choosing Cas-settes.

One cassette will be needed for each new media created in the Calibration Manager. Follow the steps below to create a new cassette:

1. Click the New Cassette button in the Cassettes window.

New

8-4 Xitron XENITH INSTALLATION

Page 51: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Calibration Manager

2. In the Name field type Avantra 44 .

3. In the Recorder Type field select TiffExport.

4. In the Media Name field select the Avantra 44 media created in Media on page 8-2.

5. In the Length field leave the default value of 100. This value is carried over from the media length.

6. Click O.K. to create the new cassette.

Screen SetsOpen the Screen Sets window by clicking on the View menu and choosing Screen Sets.

Details of each screen are displayed in the window. If support for the Epson or HP proofers was installed there will already be some default screens for those devices. A new screen must be created for each resolution and line screen to be used with the output device.

There are two types of screening available in Xenith: Adobe Accurate Screens and Xenith Quality Screens. The Xenith Quality Screens are based on the Crosfield Screening technology and it is highly recommended that all customers use the Xitron Quality Screens. All examples and references in this guide will refer to the Xitron Quality Screens (XQS).

Follow the steps below to create a new screen set.

XENITH INSTALLATION Xitron 8-5

Page 52: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

1. Click the Generate XQS Screen Set button in the Screen Sets window.

2. In the Recorder Type field Choose Tiff Export.

3. In the Resolution field Choose 2400.

4. In the Nominal Ruling field select 133.

5. In the Angle Family field choose Nominal + 7.5.

6. Select a dot shape of Euclidean.

7. Click Generate to build the screenset.

NOTE: When trying to generate a screen set the following error may occur: No potential screen sets matching your supplied parameters were found.

If this happens, click O.K. to return to the Generate XQS Screen Set window. At this time it will be necessary to modify some or all of the settings for the screen set being generated. Check to make sure that the line screen being used is neither too high nor low for the resolution selected. It may also be necessary to use the Nominal angle family instead of Nominal +7.5. Once

8-6 Xitron XENITH INSTALLATION

Page 53: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Calibration Manager

these changes have been made click Generate to try again.

8. From the XQS Search Results window select the highest number from the list and click Install to add a screen to the Screen Sets window. At this point the Generating XQS Screen Set window will appear and build the screen set.

9. Click the Close button to close the XQS Search Results window and return to the Screen Sets window.

10. Repeat Steps 1 through 10 twice to create two more screens. Create the first at 2400 dpi with a line screen of 150. Create the second at 1200 dpi with a line screen of 85. Both should use the nominal + 7.5 angle family and a Euclidean dot shape.

XENITH INSTALLATION Xitron 8-7

Page 54: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

The only modification available to a screen set once it has been generated is the comment field. Select the 2400 dpi screen and click the Modify Screen button.

Type Avantra 44 and hit O.K..

NOTE: Any screen set that is currently in use by a device cannot be deleted.

Recorders and ProofersOpen the Recorders and Proofers window by clicking on the View menu and choosing Recorders and Proofers.

In the Name field at the top is a drop down list of all available devices in Xenith. Select Avantra 44. On the Cassette Attributes tab below is a list of all

8-8 Xitron XENITH INSTALLATION

Page 55: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Calibration Manager

available cassettes. The cassette with the green light is the one Xenith cur-rently has applied to the chosen device. Select the Avantra 44 cassette and click the Load Media button. The Avantra 44 cassette is now applied to the device.

CalibrationCalibration in Xenith is dependant on the chosen device in the Recorders and Proofers window. Select the Avantra 44 device in the Recorders and Proofers window and click the Calibrate button. This will open a window titled Install Calibration for TiffExport of Default Media Type. We will refer to this as the Calibration window.

NOTE: A properly calibrated densitometer is necessary in order to accurately linearize a device. Also, depending on which densitome-ter is being used it may be necessary to allow for a warm up period in order to assure accurate readings.

Follow the steps below to create a new calibration:

1. Click the New button under the Group heading on the right side of the screen to create a new calibration group.

2. In the Name field type Avantra 44 2400 . Make sure that the Positive and Negative selection is chosen. This will allow Xenith to output both a positive and negative calibration strip upon verification and will allow for calibration of both media types at once.

3. Click O.K. to close the window and return to the Calibration window.

4. In the Resolution field under the Screen Set heading on the left side of the window select 2400.

5. Click the Browse button to have Xenith display a list of screen sets that match the selected resolution in the Screen Sets Browser. Both 2400 dpi screen sets should be listed here.

XENITH INSTALLATION Xitron 8-9

Page 56: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

6. Using the shift key, select both 2400 dpi screen sets from the list and click the Add to Group button. A confirmation dialog box will be dis-played.

NOTE: Selecting both 2400 dpi screen sets will allow for lineariza-tion of the output device at 2400 dpi for both 133 and 150 line screen at the same time.

7. Click the Expose button to output a default calibration strip to the default export folder for the device. This should be the Calibrate folder under the RBQueues folder on the Raster Blaster hard drive.

8. Using the Image File command in Raster Blaster, output the calibration strip to the Avantra 44 2400 device.

9. With a correctly calibrated large-aperture densitometer, measure the dot% of each tint block and record the value on the media.

10. Enter the measured values into the corresponding fields in the Lineariza-tion parameters. After all changes have been entered click the Apply but-ton. A confirmation dialog box will be displayed.

8-10 Xitron XENITH INSTALLATION

Page 57: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Calibration Manager

11. Click the Verify button to output two calibration strips, one positive and one negative, with the updated values to the Calibrate folder.

12. Using the Image File command in Raster Blaster, output the calibration strip to the Avantra 44 2400 device.

13. Use the densitometer to check that the dot% values are within +/- 1% of their designated values. If any dot% values are not within +/- 1%, repeat steps 7 through 11 until all the dot% values are within +/-1%.

14. Once Xenith has been calibrated for all resolutions click Close to close the window.

XENITH INSTALLATION Xitron 8-11

Page 58: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 8:

8-12 Xitron XENITH INSTALLATION

Page 59: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

9RIP MANAGER

Switch to the RIP Manager for the instructions in this chapter. If the RIP Manger is not open it can be started by double-clicking its icon on the desk-top.

PreferencesOpen the preferences by clicking on the Edit menu and choosing Preferences.

XENITH INSTALLATION Xitron 9-1

Page 60: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

On the General tab, select inches as the unit of measurement. Click O.K. to close the preferences.

On the System Tab, select a memory setting that is appropriate for your Xenith configuration. This is optimizes Xenith for the amount of memory on your computer.

Job TicketsJob Tickets determine the workflow of all jobs in the Xenith RIP. They determine what kinds of inputs are available to the RIP, which output device will be used, and what formatting will be applied to each job. Open the Job Tickets window by clicking on the View menu and choosing Job Tickets.

Creating a New Job Ticket1. To create a new job ticket, make sure no other job tickets are selected

and click the New button in the Job tickets window.

9-2 Xitron XENITH INSTALLATION

Page 61: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Rip Manager

2. In the Name field type Avantra 44 2400 .

3. In the Description field type Avantra 44 @ 2400 dpi with trapping .

4. Click O.K. to create the job ticket and bring up the modify Job Ticket window.

Setting Job PriorityJob priority is used to determine which jobs are processed first. Within prior-ity level, jobs are processed in the order they are received by Xenith. Priority can be changed on a job-by-job basis and by default should be left at medium.

XENITH INSTALLATION Xitron 9-3

Page 62: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

Setting Input ParametersThe Input parameters define how a job is sent from the client work station to the RIP. In the modify Job Ticket window, click on the Input tile to reveal the Input parameters.

There are 4 types of inputs that can be used with Xenith. They are: Drop Folder, AppleTalk Network, Named Pipe and TCP/IP Socket.

Follow the steps below to create a drop folder input:

1. Click the Drop Folder button to change to the Drop Folder input dialog box.

2. Place a check mark in the Drop Folder box to activate the dialog box.

3. Click the New Drop Folder button.

New Drop Folder

This opens the Drop Folder Configuration dialog box:

9-4 Xitron XENITH INSTALLATION

Page 63: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Rip Manager

4. In the Drop Folder Configuration window click the Browse button under the Location heading.

Browse

5. Navigate to the Xenith folder in Windows.

6. Create a new folder. Name this folder Inputs .

7. Under the Inputs folder create a new folder. Name the new folder Avantra 44 2400 .

8. Select the Avantra 44 2400 trap folder and click O.K. to add the drop folder.

Follow the steps below to create an AppleTalk input:

1. Click the AppleTalk button to change to the AppleTalk input dialog box.

2. Place a check mark in the AppleTalk box to activate the dialog box.

XENITH INSTALLATION Xitron 9-5

Page 64: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

3. An AppleTalk input matching the name of the job ticket will now appear as a chooser level item.

Setting RIP ParametersRIP parameters define how the RIP responds to various job conditions. Fol-low the steps below to define the RIP process:

1. Select the Rip tile and double click to open it:

2. Under PostScript Format select Auto detect. This will allow Xenith to determine whether the incoming job is being sent as composite or sepa-rated work.

3. Under Composite PostScript set the Automatic ink mapping to *CV?⎝*C. This will allow the RIP to consolidate Pantone colors that may be the same, but have different names to one plate. i.e. Pantone198CVC and Pantone198CVU would both become Pantone198C.

4. Check Fail if missing fonts to force the RIP to fail any job which does not have all it s fonts imbedded.

5. Leave Fail if not linearized checked. This function will cause jobs to fail if they are sent to any device in Xenith that has not been linearized.

9-6 Xitron XENITH INSTALLATION

Page 65: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Rip Manager

6. Select Overprint to allow overprinting in jobs. Under Type of overprint select Black and PostScript. This will force the RIP to overprint black objects and honor overprints set in the job.

7. If you have purchased In-Rip Trapping, you can check the In-Rip Trap-ping box to allow Xenith to trap incoming jobs. Under Trap style choose Default.

8. The In-RIP-Trapping option will only be available if you have purchased the In-RIP-Trapping option.

9. Place a check mark in the Pre-Check box. Selecting Pre-Check allows the RIP to check that a PostScript job does not have syntax errors, miss-ing fonts or missing image dots that would prevent successful process-ing.Close the settings window.

Output Tile Click on the Output tile. The Output tile is divided into three parts, which correspond to the three buttons located on the left hand side of the window.

The top button is the Page Setup button

XENITH INSTALLATION Xitron 9-7

Page 66: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

Page Setup Parameters1. Click on the Page Setup button.

Page Setup

2. Select Override Application Settings. This will allow Xenith to override any negative, lateral reversal and rotation settings that were set in the front-end application.

3. Select the Negative and Lateral reversal options.

9-8 Xitron XENITH INSTALLATION

Page 67: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Rip Manager

Screening ParametersThe second button on the Output tile is the Screening button.

1. Click the Screening button to reveal the Screening parameters.

Screening

2. Select 2400 as the Output resolution.

3. Select the Override application screening settings option. This will allow Xenith to apply screening to the incoming job.

4. On the Screen Set tile make sure the Screening mode is set to HalfTone.

5. Click the Browse button to open the Screen Set Browser window.

BrowseScreen sets matching the resolution chosen in step 2 will be displayed. Select the 2400 dpi, 150 lpi screen set and click the Select button.

XENITH INSTALLATION Xitron 9-9

Page 68: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

Output ParametersThe third button on the Output tile is the output button.

1. Click the Output button.

Output

2. The Compression to disk determines how the Tiff file will be compressed when Xenith initially writes it to the hard drive. In the Compression to disk field choose LZW.

3. The Compression to device determines how Xenith writes the Tiff file to Raster Blaster. In the Compression to device field choose LZW. LZW is a lossless compression that allows for efficient communication between Xenith and Raster Blaster.

NOTE: It is important that neither compression field be left at the none setting. Doing so could result in the creation of extremely large files and cause communication problems between Xenith and Raster Blaster.

The default export folder chosen when creating the device is displayed in the Folder filed under Export Method.

9-10 Xitron XENITH INSTALLATION

Page 69: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Rip Manager

4. Click the Browse button next to the Folder field.

Browse

5. Select the Avantra 44 2400 queue folder under RBQueues and click O.K.

.

6. Open the output tile by double clicking it. From the drop down list select Avantra 44. This will add an Avantra 44 tile to the Modify Job Ticket window.

7. Place a check in the Hold before output to device box. When this option is selected, the output mode for Xenith is forced to be To Disk . Select this to stop the job from being downloaded to the recorder directly after processing. This will allow the final output to be checked in the Viewer

8. Click O.K. in the Modify Job Ticket window to add the job ticket to the Job Ticket window.

XENITH INSTALLATION Xitron 9-11

Page 70: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 9:

Copying a Job TicketSelecting a job ticket in the Job Ticket window before clicking the New but-ton will cause all parameters of the highlighted job ticket except the drop folder location to be carried over to the new job ticket. This makes it easy to create multiple job tickets with similar settings.

Select the Avantra 44 2400 job ticket.

Follow the steps below to make a copy of this job ticket with similar settings and a new drop folder:

1. Click the New button in the Job tickets window.

New Job Ticket

2. In the Name field type Avantra 44 1200 .

3. In the Description field type Avantra 44 @ 1200 dpi with trapping .

4. Click O.K. to create the job ticket and bring up the modify Job Ticket window.

5. Create a new drop folder and name it Avantra 44 1200 .

6. On the Output tile, under screening parameters, change the resolution to 1200.

7. Click the Browse button to open the Screen Set Browser window. Select the 1200 dpi, 85 lpi screen set and click the Select button.

8. On the Output tile, under Output parameters, Click the Browse button next to the Folder field.

BrowseSelect the Avantra 44 1200 queue folder under RBQueues and click O.K.

9. Click O.K. in the Modify Job Ticket window to add the job ticket.

9-12 Xitron XENITH INSTALLATION

Page 71: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

C H A P T E R

10PRINTING A TEST JOB

Once Xenith and Raster Blaster (or another TIFF catcher) are installed and configured it is a good idea to print a test job from each before attempting to run production work through the system. This chapter explains how to run a test job through each application.

Raster Blaster Test JobThere is a selection of 1-bit Tiff files located in the Test Files folder in the Raster Blaster directory on the hard drive. The files are available in 1200, 1270, 2400 and 2540 DPI. Follow the steps below to image a test file from Raster Blaster:

1. Select the Golfer2400Mono file.

2. Drag it into the input folder that you set up previously. for 2400 dpi.

3. Deselect the Disable Output option in RasterBlaster to release the file.

XENITH INSTALLATION Xitron 10-1

Page 72: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 10:

Process the film or plate to check that the file has been imaged appropriately.

Xenith Test JobThere is a selection of PostScript and PDF files located in the Testpages folder. The Testpages folder is located in the User directory under the Xenith program directory. Follow the steps below to image a test file from Xenith.

1. Make sure Disable Output is unchecked in Raster Blaster.

2. Copy the a5comp.pdf file from the Testpages directory to the Avantra 44 2400 input queue for Xenith.

3. Xenith will now RIP the file, placing the separations to be output to Ras-ter Blaster in a hold status.

4. Open the Job Queue in the RIP manager by clicking on the View menu and choosing Job Queue.

5. Locate the a5comp job in the Job Queue.

6. Click on the green triangle to the left of the job. This will display page one of the job and highlight it.

7. Release the separations to Raster Blaster by clicking on the Release but-ton in the Job Queue.

10-2 Xitron XENITH INSTALLATION

Page 73: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Printing a Test Job

8. Check output to ensure that the orientation is correct and that the job is right reading emulsion down.

If any of the above is incorrect, exit Xenith and start the Recorder Utilities. Use the orientation feature to modify the final output. For example, if the file needs to be rotated 90 degrees, change the setting from Top to Bottom, Left to Right to Left to Right, Top to Bottom. To change emulsion up to emulsion down, change Left to Right to Right to Left. For more information on Orien-tation, see the Xenith RIP manual.

Congratulations!You have completed the Xenith Install Guide. At this time both Xenith and Raster Blaster should be installed and functioning correctly on your PC. For further questions regarding the install or configuration of Xenith or Raster Blaster, please refer to the Users Guide for that application.

XENITH INSTALLATION Xitron 10-3

Page 74: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Chapter 10:

10-4 Xitron XENITH INSTALLATION

Page 75: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

A P P E N D I X

ASETTING UP A SLAVE PC

As stated in Chapter 6: Configuration Tool, Xenith gives users the ability to control additional RIPs from the Xenith server. These additional slave RIPs allow Xenith to balance it s work load across several PC s. Though it is nec-essary to purchase an additional license to run a slave RIP, it is not necessary to purchase an additional dongle. Also, all functionality of the slave RIP is controlled from the Xenith server.

Setting Up the Slave PCThe first step in setting up the slave system is preparing the slave PC. Before installing the software the following tasks should be completed:

Windows 2000 or 2003 server or 2k or XP Pro with the latest service packs should be installed on the slave PC.

NetBEUI protocol must be installed on the master PC.

A static IP address should be assigned to the slave PC.

The drive that will contain the Xenith software must be shared.

Connectivity from the slave PC to the Xenith server should be estab-lished using the PING command from the command prompt. At the com-mand prompt type:ping<space>IP address of Xenith server<enter>

If connectivity is established, the network server will reply. If connectivity has not been established a Request Timed Out error will be received.

XENITH INSTALLATION Xitron A-1

Page 76: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix A:

Installing Xenith Software On the Slave PCXenith should be installed on a hard drive that is separate from the windows system files. This will ensure enough room is available on the drive as tem-porary working space for Xenith and also for file storage. Follow the steps below to install Xenith:

1. Log in to Windows as a user with administrator privileges.

2. Insert the Xenith CD in the PC.

3. The installation program checks to see if all the necessary system files are in place on the computer. If all the system files are there, the installer will switch to the Welcome screen. If the installer finds that the system files need to be updated, it will automatically perform this procedure. The installer will then ask that the PC be rebooted. When the PC has fin-ished rebooting, restart installation by running the setup.exe file located in the Xitron folder on the Xenith CD.

4. At the Welcome screen click Next.

5. Enter the name and location of the folder in which Xenith will be installed. The browse button may be used to locate or create a folder on the local hard drive. Once a folder has been defined, click Next.

A-2 Xitron XENITH INSTALLATION

Page 77: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Xenith will load the component installer and then display the Bundle Selec-tion screen:

6. Of the available options, choose only the Xenith RIP Slave System. Click Next to continue.

7. At the Component Confirmation screen, Xenith will list the selected Bundles at the top and individual components at the bottom. Click Next to continue.

8. Xenith now displays the Confirm window listing all components to be installed. Click Cancel to quit or O.K. to continue.

Page 78: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix A:

9. The check Install Paths dialog box lists the working directories Xenith will use after installation. Click O.K. to continue.

10. The component installer will now display a Progress window and begin copying files to the hard drive. Clicking Cancel at any time will abort the installation process.

A-4 Xitron XENITH INSTALLATION

Page 79: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

11. Once finished the Component installer will display the Completed win-dow and a list of the successfully installed components. Click O.K. to continue.

12. The Component Installer window will now be displayed. To finish installation click on the File menu and chose Exit.

13. Choose Yes to restart the computer.

Page 80: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix A:

Adding a Slave with the Configuration ToolThere are several ways to use a slave PC with Xenith. The most common way is to use the slave PC as an additional RIP. Using the slave PC as an additional RIP allows Xenith to balance the workload across two computers and helps to alleviate bottlenecks in workflow. The multiple RIPs are referred to as a cluster. Follow the steps below to add the slave PC as an additional RIP in the Configuration Tool:

1. Start the Xenith Configuration Tool. PC Box [0] should be open in the display.

2. Click on the File menu and choose New. A new window titled PC Box [1] will be displayed.

3. Click on the File menu and choose Import Slave PC. The import dialog box will be displayed.

A-6 Xitron XENITH INSTALLATION

Page 81: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

4. Uncheck the Outputs/Proofers option in the Import slave dialog box.

5. On the Import Slave dialog box, click the Browse button.

Browse

6. Using a UNC path, navigate to the Xenith installation folder on the slave PC.

7. Click the Select Folder button. The path to the Xenith installation folder is now displayed in the Import Slave dialog box.

8. Click O.K. to import the slave PC. PC Box [1] will now display it s Adobe RIP components.

Page 82: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix A:

9. Double click on the Adobe RIP icon. Change the name to Slave 1.

10. Click O.K. to save the change.

11. Click on the File menu and choose Exit.

12. Click O.K. at both dialog boxes to save changes to PC box [0] and PC Box [1].

The slave RIP will now be an available option in the RIP tab of the Xenith job ticket.

A-8 Xitron XENITH INSTALLATION

Page 83: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Starting the Slave RIPBefore Xenith can send jobs to the slave RIP it must be started. Follow the step below to start the slave RIP:

NOTE: The Xenith Server should be online before starting the slave RIP.

1. On the slave PC, click on the Start menu and navigate to Programs/Xitron Xenith and click on the Start As Slave icon. The Xitron Slave Applications window will be displayed, and then minimized to the Start bar.

NOTE: It is important to always use the Start As Slave option when starting the slave RIP. Using the Start System option will start the slave RIP as a stand-alone RIP and cause it to be unavailable to the Xenith server.

Page 84: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix A:

Using the Slave RIPThe slave RIP is controlled from the RIP tab in a Xenith job ticket. In the RIP Manager, open the Avantra 44 2400 job ticket and click on the RIP tab. Notice that the RIP Queue drop down menu is set to Any. Clicking on the drop down menu will display three options: Any, slave 1 and Xenith master.

Using the Any setting, Xenith will first attempt to send any new job printed to the Avantra 44 2400 job ticket to the Xenith Master RIP. However, if the Xenith Master RIP is busy, Xenith will send the job to the Slave 1 RIP. If both RIPs are busy, the new job will wait in the Job Queue for the first avail-able RIP. This option makes the best use of all resources available to Xenith.

By selecting either Xenith Master or Slave 1 in the RIP Queue menu, Xenith will force any job printed to the Avantra 44 2400 job ticket to that RIP. If the selected RIP is busy the job will wait in the Job Queue for the RIP to finish. This option is useful for isolating large jobs on one PC.

NOTE: If a job ticket is set to use the slave RIP and the slave RIP is not started, any job printed to that job ticket will wait indefinitely until the slave RIP is started.

A-10 Xitron XENITH INSTALLATION

Page 85: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

A P P E N D I X

BSYSTEM ELEMENTS

System ElementsThe Configuration Tool uses a system of building bricks known as Elements. The system elements are:

¥ Rip Server

¥ Output

¥ Input

¥ Primer

¥ Adobe RIP

¥ ROOMProof

¥ File Importer

¥ Storage

¥ Devices

Each element may be added to the PC Boxes you define in the Configuration Tool. This Appendix provides a brief explanation of the purpose of each ele-ment, and specific information such as when the element is needed, and any requirements and limitations that apply when using the element.

RIP ServerThe RIP Server identifies the PC Box with its network names.

XENITH INSTALLATION Xitron B-1

Page 86: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix B:

OutputThis element is the application that drives all of the image setters and other output devices. If you configure a device on a PC Box, then you must have one of these to drive it. You can only have one per PC Box.

Input

This is the application that monitors drop folders and simulates Post-Script printers on the network. There must be at least one of these in the Cluster, and there may be up to one per PC Box. If you want a directly connected printer to a RIP on a Slave PC (for things like font downloaders), then you must configure an Input on the slave PC.

Primer

This is the application that converts PostScript to PDF and performs pre-flight checks on the PDF. You can only have one of these per

cluster, but it can be configured to run on either the Master or any Slave PC Box.

Adobe RIP

This is the application that converts PostScript or PDF to rasterised images. You can configure these on either the Master or Slave PC Boxes, and you can have more than one per PC Box. The system will automatically distribute work across all RIP elements.

ROOMProof

This is the application that converts images ready for the imagesetter or platesetter back into images suitable for a proofing device. You can only have one of these per cluster, but it can be configured to run on either the Master or any Slave PC Box.

B-2 Xitron XENITH INSTALLATION

Page 87: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

File Importer

This is the application that imports and converts other file formats such as TIFF/IT. Currently you can only have one of these per cluster, and it must be configured to run on the Master PC Box.

Storage

Each of these elements represents an area of identified file storage. These can be configured freely and multiply on any Master or Slave PC Box. Each identifies where the storage is and what it should be used for.

Devices

Each of these elements represents an image output device proofers, imagesetters, platesetters, etc. For SCSI interfaced devices the device must be configured on the PC Box to which the device has been attached, but so called remote devices may be configured elsewhere.

Page 88: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix B:

B-4 Xitron XENITH INSTALLATION

Page 89: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

A P P E N D I X

CDEFINING PATHS TO FOLDERS

IntroductionWhen using the Configuration Tool, it will be necessary to specify the loca-tion of folders in a number of different places. The location of folders can be specified in two different ways. The method of specifying the path to a folder is very important, and the preferred method will change depending on the circumstances.

Methods of Path SpecificationThere are two different methods of specifying a path to a file.

Drive Letter and Colon Method

Universal Naming Convention Method

These methods are discussed in detail below.

Drive Letter and Colon MethodThe more traditional method is to use the drive letter and colon , such as

C:\folder1\folder2\file . The problem with this method is that a drive let-ter, in particular for a C drive, will normally mean different things on dif-ferent machines. So if a path to be used on more than one machine, this method will usually not produce the desired results.

XENITH INSTALLATION Xitron C-1

Page 90: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix C:

Universal Naming Convention MethodThe alternative to the Drive Name and Colon method is to use the UNC (Universal Naming Convention) method. This method follows a format, such as:

\\Pcnetwork name\shared drive name\folder1\folder2\file

Using the network name of the PC means that the path will mean the same thing to any PC on the network. To specify a path in this fashion, simply use My Network Places as a starting point when specifying the path.

NOTE: To use the Universal Naming Convention method, the drive must be shareable on the network, and the shared drive name must not be the default share name of <drive letter>$).

Access by Multiple PCs

The advantage of using UNC for the folder path name is that the folder becomes accessible by all the PCs in the cluster. However, the first time Windows accesses the file it can be much slower than when the path is spec-ified with a drive letter.

If a file is to be accessed by a number of PCs, then there is normally no alter-native to using a UNC path. If a file is to be used only on it s local PC, how-ever, the system will work more efficiently if the path is specified using the drive letter and colon method.

Path Definition for Xenith FoldersThe table below lists the different folders used by Xenith and the recom-mended method for defining the path to each folder:

C-2 Xitron XENITH INSTALLATION

Page 91: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Folder Name(s) Method of Defining Path to Folder

Rip General Store, RIP Specific Store, ROOMProof Store, Importer General Store

UNCThese will have to be accessed by all the PCs in a cluster, and generally they are used for large files that are only rarely opened and closed.

Installation Folder Master PC — UNCSlave PC — Drive letter and colonThe Installation Folder store is used to tell slave PCs where they can find the applications to run. If it has not been specified locally, then the slave PCs will look up this path on the master PC. Therefore, on the Master PC, the path must be portable and must use UNC.On the slave PC, the path will only be used locally, so the drive letter and colon method will be used.

RIP Resources, RIP Screens

Drive letter and colonIt is recommended that these files are located on the same PC as the Adobe RIP, which means that the drive letter and colon method can be used.

RIP Resources for Primer

UNC/Drive letter and colonIf the resources folder is located on the same machine as the Primer, then use the Drive letter and colon method. If the folders are located on a differ-ent machine, then use UNC.

Normalizer Resources

Drive letter and colonIt is recommended that the Normalizer resources file is located on the same machine as the Normalizer, so the Drive letter and colon method will be more efficient.

Color Table Folder UNCThe Color Table Folder can be on any PC in the cluster, so the path to it must be specified using UNC.

Default Export Folder

UNCThe Default Export Folder can be on any PC in the cluster and therefore must be specified using UNC.

Page 92: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

Appendix C:

C-4 Xitron XENITH INSTALLATION

Page 93: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

XENITH RIP WITH PDF WORKFLOW

AAbout This Guide 1Add Monitor button 5Add New Device 1, 6Adobe Accurate Screens 5Always use Device and PSet associated with Queue 5Avantra 44 1, 2, 5, 1, 2, 5, 9BBefore you Begin 1Bi-level images 9Browse button 5buttons

Add to Group 10Apply 10Calibrate 9Expose 10Load Media 9New

Cassette Data 4Media Data 2

New Cassette 4New Job Ticket 2Verify 11XQS Screen Set 6

CCalibrate button 9Calibrate folder 10Calibration 9

groupcreating 9

linearizing 9Manager 1

Starting 8window 9

Cassette Menu 3Cassette window 4Cassettes

configuring 4Clients

Remote 1

Page 94: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

PRELIMINARIES

Component Confirmation screen 2Component Installer 5, 8Configuration

Macintosh Viewer 4New Queues 4Queue Folders 1

Configure Queue dialog box 4Configuring

Devices 1Creating

New Devices 1Creating a Second Device 6Crosfield Screening 5DDefault Export Folder 2Default Image Open 5, 9Default Media Type 2densitometer 9, 10, 11Device

Configuration 1Creating a new device 1Setup 1Tab 2

Device Configurationdialog box 2Example 6Tabs 2

Device Type 1dialog box

AppleTalk input 5Configure Queue 4Device Configuration 2Enter License 6

DNS server 5Dongle Pass Codes 6Dot Shape

Euclidean 6Driver Config button 2Driver pop-up menu 1

Page 95: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

XENITH RIP WITH PDF WORKFLOW

EEdit Menu

Preferences 1FFast Scan Size 2File Menu

Configure Devices 6GGeneral Options window 5, 9IInputs folder 5Installation

Completed window 8Raster Blaster 1Xenith 1

InstallingMacintosh Clients 2

Installing Licenses 6Introduction 1JJob Priority

Setting 3Job Ticket

AppleTalk Network 4creating a new Job ticket 2Drop Folder 4Input Parameters 4Named Pipe 4TCP/IP Socket 4

Job Ticket window 4LLength

Media 2License Tool 6Licenses

Xenith Options 6Linearization parameters 10Load Media button 9MMacintosh Clients

Page 96: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

PRELIMINARIES

Starting 4Macintosh Viewer

Configuring 4Max Height 2Max Media Thickness 2Max Width 2Media 2Media Format 2media length 5Media Name field 5Media Type 2Media Type field 2Media window 2, 3Monitor Points 5Nnetwork identification name 5

Xenith Server 9New Device button 6New Drop Folder 4New Job Ticket 12New Media button 2OOptions menu 9Options Tab 4Orientation 2Output Devices window 2Override Job Resolution 6PPAGEBUFF 4PC Clients

Starting 8PC Viewer

Configuring 9Point Sample Sizes 9Preferences 1

configuring 1General tab 1, 2

ProofersConfiguring 8Epson 5

Page 97: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

XENITH RIP WITH PDF WORKFLOW

HP 5PSets 1QQueue Folders 1Queue Setup 1RRaster Blaster

Image File command 10, 11Installation 1Removing 3

Raster Blaster DeviceDeleting 3

RBQueues folder 10Recorder Type field 5Recorder Utilities 1Recorders

Configuring 8Recorders & Proofers

Cassette Attributes tab 8Recorders and Proofers 8Remote Clients 1Remote Server 5

Name 5Remote Server Name 9Resolution Menus 3RIP Manager

Starting 8Rip Manager 1Rows Per Strip 2SScreen Sets 5

Angle Family field 6dot shape 6Nominal Ruling 6Recorder Type 6Xenith Quality 5

Screen Sets window 7Screening

Crosfield Technology 5Screens

Page 98: X ENITH P RODUCT L INE - Xitron Inc · 2013-03-27 · X ENITH P RODUCT L INE I NSTALLATION M ANUAL V ERSION 6.0 101-0008-014 Phone: 734 / 913-8080 Fax: 734 / 913-8088 Xitron, Inc

PRELIMINARIES

Adobe Accurate 5Setting Up a Slave PC 1Settings Tab 3setup.exe file 7Slow Scan Size 2Start Menu

Start System 1Start System 1Supply Tab 5TTakeup Tab 5TCPIP 4TCPIP address 6

Xenith Server 5, 8Tiff Export 6Tiff file output 2Type pop-up menu 2UUnit of Measurement 1VView Menu

Cassettes 4Screen Sets 5

View menuMedia 2Recorders & Proofers 8

Viewer 4WWelcome screen 1Width

Media 2Workflow Parameters 6XXenith

Installation 1Xenith Quality Screens 5XQS (Xenith Quality Screens) 5XQS Screen Set 6ZZoom 9