www.siemens.com/unity
Unity 3Maximum efficiency – Minimum size.For precise diagnostics and effortless fitting.
Siemens Unity™ 3 is a PC-controlled diagnostic and fitting system designed to simplify and speed up many of your daily work processes. Above and beyond that, it makes your business more cost-effective by minimizing downtime for calibration and service.
Unity 3
The modular hardware and software system components offer the utmost flexibility to fit your individual needs, and its versatility enables faster and better measurements – so you can offer your customers a more pleasant, comfortable fitting experience with more precise results. Learn how Unity 3 intuitively supports the work of any Hearing Care Professional – before, during and after the fitting process.
Easy to use
Common software interface across all Unity modules follows the typical workflow and fitting steps carried out by Hearing Care Professionals.
Binaural measurements can be performed simultaneously, reducing measurement time by half.
Flexible probe microphone system enables uncomplicated positioning of probe microphones, regardless ofear size.
Enhance your workflow and maximize customer satisfaction.
The perfect modular concept:Fitting unit attached to the
hearing instrument testbox unit.
Hearing instrument testbox unit.
Fully compatible with Noah fitting software for seamless integration.
Seamless integration with Connexx™ 7 and thanks to AutoFit™, there is no need to toggle between different fitting tools.
Unity’s completely independent architecture enables use as a standalone system with your own patient database.
Smart service support
All transducers have their own calibration data stored on-board. Thanks to the plug and play concept, you do not need to wait for the calibration service to come but can simply plug them in and start working.
No service downtime: Benefit from plug and play transducers and perform sound-field calibration with the included measurement probe microphone.
Automatic software updates and upgrades with Siemens update manager.
Small dimensions
Unity has never been smaller or lighter.
Fits any room concept: The fitting unit can be attached below a desktop or partly mounted to a wall.
Take only what you need: The modular system can be disassembled and allows taking only the small fitting unit with you on the go while leaving the larger testbox behind.
testbox unit.
Hearing instrument testbox unit.testbox unit.
2
Audiometer Module
It enables comparison and timely analysis of changes and a 16 kHz view for high frequency losses. In addition, the speech audiometry monitoring function helps the clinician to automatically score the results and protocol the used test words as well as the given answers. This avoids repetition of test words in later sessions.
With high-frequency, pure-tone testing up to 16 kHz and the ability to perform Weber and TEN tests, the audiometer module is able to support all common hearing tests. The module can be controlled via keyboard and mouse, and the interface features include a lot of overlay options in the audiometer view.
The fully functional two-channel diagnostic audiometer module is optimized for pure-tone and speech audiometry, plus a host of other premium features.
Module 1
The portable combination of headphones and fitting unit allows
for a comfortable, personalized hearing analysis – even when you
are out on visits.
Fitting unitThe fitting unit combines high quality components with plug and play technology for convenient connection of headphones, microphones, probes and your PC.
DD45 headphones Fitting unit
Premium possibilities at your fingertips.
1
1
4
Speech audiometergraphical viewThe speech audiometer graphical display allows both manual and automated input of speech test results. Used test word lists and client responses will be stored together with the data and can be displayed for each test point on demand.
HF audiometry screenThis screen provides a true binaural view on
the frequency range up to 16 kHz with all relevant data and required controls in one
screen. The clearly structured screen provides a maximum in overview and supports
intuitive handling.
5
Real Ear MeasurementFast, individual fitting for the real world.
Real ear measurement screenWith a binaural view of real time measurement data, this screen allows you to visualize all the necessary information.
Modul 2Module 2
Testing and evaluation options
Possible measurements: Unaided, aided, occluded (both gain and output); insertion gain and RECD.
Practical test signals: ISTS, LTASS, ICRA and many different noises
Applicable prescriptive formulas: DSL v5, NAL-NL1 and NAL-NL2 and manual target input for individualized evaluation.
The adjustable probe microphone system enables easy placement. Binaural measurements can be performed simultaneously to improve your workflow. And the module is compatible with AutoFit from Connexx 7.3 onwards for the fastest possible individual fitting.
Probe microphones Fitting unit
Together with the fi tting unit, the robust probe microphones deliver perfect measurement results. They can be fl exibly adjusted to fi t any ear: No matter what the size or form, they sit comfortably and securely – even when testing children.
Unity 3’s real ear measurement module delivers real-world test results with exceptional features and measurement options.
6
Speech Mapping ModuleClear visualization for excellent fitting results.
Speech mapping screenUse this screen to visualize how the hearing
instruments process live speech, recorded speech or any other noise. You can also
demonstrate hearing instrument features such as noise reduction or directionality, and
explain their effects to your client.
Percentile analysis screenThis screen allows you to visually display and
analyze the dynamic range of live signals that are processed by the hearing instruments.
Its analysis includes the whole spectrum of broadband sound signals. Percentile analysis
also provides means to adjust the hearing instruments for both the loud and the soft
parts of a speech signal.
Module 3
Professionals reap the benefits, customers hear the difference:Speech mapping allows you to visually demonstrate hearing instrument benefits so that your customers can experience the difference first-hand, right away. A large selection of sound samples assists you during tests and demonstrations. The percentile analysis function enables fittings for non-linear hearing instruments. And simultaneous binauralmeasurements help you to serve your customermore efficiently than ever.
7
Hearing Instrument Testbox Unit
Module 4
Accurately pre-set and test hearing instruments with the large testbox. Its stylish design makes it a professional eye-catcher for your offi ce environment.
Testbox UnitAccurately pre-set and test hearing instruments with the large testbox. Its stylish design makes it a professional eye-catcher for your offi ce
The hearing instrument testbox unit features a large test chamber to provide excellent acoustics for hearing instrument tests and hearing instrument configuration before your customer arrives.
Standard available tests
IEC 60118-7 IEC 60118-15 (in combination
with speech mapping module) ANSI S3.22
Outstanding elegance andprecise measurements.
8
HIT measurement screenThe HIT measurement screen demonstrates what is happening inside the testbox unit during test sessions. It provides clearly structured test orders, automatic test runs and readout of data.
Outstanding elegance andprecise measurements.
9
Efficient choice
Unity 3 integrates common, user-friendly workflow logic in all modules.
Pre-calibrated transducers canbe quickly serviced.
Use with your own patient database, independent from any integrated systems.
Simple integration with Connexx or Noah fitting software.
Buy only what you need: The software and components can be purchased separately.
Ultimate convenience
Simple plug and play installation of all parts.
USB-powered fitting module is detachable and light-weight.
Modular operation: The standalone testbox can be used independently of the fitting module.
Flexible connectivity.
The perfect match
Innovative modern design and classy appearance.
Fits all room concepts – suitable for wall mounting 1 and desktop use 2 .
1 2
Unity 3 provides the discerning acoustician with
all the necessary hardware and software to simplify and speed
up their everyday workflow.
The perfect all-round solution for the fitting process: Unity 3 is expandable with useful and convenient accessories.
Your ideal business partner – Unity 3’s modern design and sophisticated technology make it an attractive complete solution for precise diagnostics and effortless fitting.
Unity 3The heart of your fi tting system.
10
Unity 3 Fitting unit
Item Description Value
Mechanical Data
Unity 3 Fitting unit, w/o cover External measures L x W x H 330 x 117 x 28 mm
Unity 3 Fitting unit with cover External measures L x W x H 338 x 134 x 92 mm
Weight, w/o cover 475 g
Weight with cover 800 g
Electrical Data
Power supply low power 5 volts USB power Max. 500 mA
Power supply high power 15 volts power DC adapter, type FRIWO FW7362M Max. 30 watts
Free-field output amplifier w/overload protection Min. 3 x 20 watts in 4 ohms
Line out 1 (stereo), Line out 2 (stereo),
Line out 3 (stereo)
500mV RMS Max. load 16 ohms
Fuses Autofuses
Environmental Data
Warm-up-time (if stored at room temperature) 1 minute
Operating temperature 15 to 35 °C
Storage temperature -30 to +70 °C
Humidity 0 to 90 % non-condensing
Connectors
DC power Pin: positive supply (+) Ring: negative supply (-) Pin 2.5 mm/Hole 7.0 mm
USB 2.0 Type B
Left / Middle / Right speaker Anitek, HS-02-1-0-5-0, black 3 pcs.
Line out 1-3 Stereo mini jack 3.5 mm
Operator and talk back mic input Stereo mini jack 3.5 mm
Client monitor headset Stereo mini jack 3.5 mm
Air conductor 1, Air conductor 2,
Air conductor 3 (HF)DIN 8 pin
Bone conductor DIN 8 pin
Client response DIN 8 pin
Real ear probe input DIN 8 pin
Option DIN 8 pin
Parts & Accessories
USB cable USB (A) and (B) connector 1.5 meter
Headset with boom-microphone Monitor headset for operator monitor and talk over optional
Headset w/o mic Monitor headset for operator monitor optional
Microphone Table stand microphone for talk over or talk back optional
Insert earphones Audiometric insert ear-phones with
built in talk back microphone 250 – 8000 Hz, optional
EAR 3A insert earphones Ethymotic research insert earphones 250 – 8000 Hz, optional
DD 45 headset Supraaural audiometric headset, collapsable 125 – 8000 Hz, optional
Technical Specifications
11
Unity 3 Fitting unit
Item Description Value
Parts & Accessories (continue)
HDA 200/300 headphone Circumaural audiometric headset with damping caps, collapsable
125 – 16.000 Hz, optional
B 71 bone conductor Mastoid transducer for bone conduction 250 – 8000 Hz,
Client response Single button switch
Sound field speaker Coaxial speakers, black, mountable on a stand optional
Real ear probe Binaural probe set with reference mic. and on-ear fixation
125 – 16.000 Hz, optional
Fitting unit cover Cable protection cover, removable, with power light indicator
DC-Power supply 15 volts power DC adapter, type FRIWO FW7362M Max. 30 watts
Safety standards General safety and essential performance of medical devices
IEC 60601-1:2005, (UL 60601-1:2003 and CAN/CSA-C22.2 No. 601.1 in preparation)
Unity 3 HIT unit
Item Description Value
Mechanical Data
Unity 3 HIT unit External measures L x W x H 300 x 340 x 135 mm
Weight 4.5 kgs
Electrical Data
Power supply low power 5 volts USB power Max. 500 mA
Power supply high power 15 volts power DC adapter, type FRIWO FW7362M Max. 30 watts
Fuses Autofuses
Environmental Data 8 pin
Warm-up-time (if stored at room temperature) 1 minute
Operating temperature 15 to 35 °C
Storage temperature -30 to +70 °C
Humidity 0 to 90 % non-condensing
DC power Pin: positive supply (+) Ring: negative supply (-) Pin 2.5 mm/Hole 7.0 mm
Connectors
USB 2.0 Type B
Left HI-PRO input
Right HI-PRO input
6 pin mini DIN
6 pin mini DINoptional
Monitor headset Stereo mini jack 3.5 mm
Parts & Accessories
USB cable USB (A) and (B) connector 1.5 meter
DC-Power supply 15 volts power DC adapter, type FRIWO FW7362M
Max. 30 watts
Programming-interface cables (2x) Connection cables to Hi-Pro or NoahLink
Reference microphone Electret goose neck type 6 pin DIN
Coupler microphone Electret type 6 pin DIN
Coupler body 2cc coupler body with attachements for BTE, ITE and body-worn hearing instruments
BTE tube PVC tube Length 25 mm
ITE putty To fasten ITE hearing instruments
Battery pill kid, 5 sizes Type: 5A, 10A, 312, 13, 675
12
Unity 3 Probe
Item Description
Standards supported IEC 61669:2001; IEC 60118-15: 2012; ANSI S 3.46: 2012
No. of channels 4
Signal types Pure tone, warble tone, narrowband noise, white noise, speech-weighted noise, pink noise, ICRA, ILTASS, ISTS
Frequency range 125 – 16.000 Hz
Signal levels 50 to 90 dB SPL
Tolerance +/- 4 dB
Pure tone accuracy Within 0.2 %
Distortion Less than 1%
Operation mode Single side or true binaural
Prescription targets NAL-NL1, NAL-NL2, DSL v5, manual input
Measurement views Output-SPL, gain-dB, combined SPL/gain, input-SPL, combined Input-Out-put, coupler
Diagram type Dual, single, top-mode
Filtering 1/3 octave, 1/24 octave, smooting
Level steps 1 dB, 2 dB, 5 dB
UCL Limiter -15 to +10 dB, selectable in 5 dB steps.
Target view 1-level, 3-levels (selectable)
Classical REM
Measurement types REU, REO, REA, REI, RECD
Item Description
Classical REM
Diagram overlays Stimulus monitor (input, output, diff);
cursor lines with read out
(level, frequency, diff), targets
Curve view Line spectra, bar graph spectra, curve
Speech mapping
Measurement types Live spectra (peak & average),
percentiles, hearing loss simulator,
HI simulator
Additional views Percentile gain, LTASS gain, relative
percentile gain, relative LTASS gain
Diagram overlays Speech bananas, speech letters, severity, normal hearing, hearing thresholds, cursor lines with read out (level, frequency, diff.), stimulus monitor, targets
Curve view Line spectra, bar graph spectra, curve, distribution
Signal input Media Control (CD, WAV), external signal
Unity 3 Probe set
Light-weight probe microphone set
Adjustable left and right ear-hangers, each with probe and reference microfone and flexible tube guide and 1.5 m connection cable
Frequency range 125 – 16.000 Hz
Maximum input level probe tube 125 dB SPL with less than 3 % distortion. Max. 135 dB SPL
Unity 3 Audiometer
Item Description
UCL Limiter -15 to +10 dB, selectable
in 5 dB steps
Audiogram overlays Speech bananas, letters,
world sounds, calculated UCL,
range limits, PTA
Speech audiometry IEC 60645-2, type A, A-E
Word presentation Continuous, stepped
Input signals Audio signal via USB from computer (CD, WAV); large sound library, support of all speech test CD‘s
Word scoring Automatically, manually
Score buttons Correct, false, not heard
Selectable views Audiogram grid, table view, w. tone audiogram
Result logging Stores list of words and results for each word together with the measuring point
Tests types (speech) SRT, SD, MCL, UCL, SD-A, SDN, SDN-A
Number of curves in audiogram Max. 4 of each type
Other tests Weber test, TEN-test
Item Description
No. of channels 2
Tone presentation Steady, pulsed
Signal types Pure tone, warble tone, narrowband noise, white noise, speech-weighted noise, pink noise
Frequency range 125 – 16.000 Hz
Hearing levels -10 to 120 dB HL at mid frequencies
Deviation 0.5 dB
Pure tone accuracy Within 0.2 %
Distortion Less than 1 %
Masking side Same, opposite, both
Level steps 1 dB, 2 dB, 5 dB
Pure tone audiometry IEC 60645-1, class I; IEC 60645-4; ANSI S3.6 class I
Tests types (pure tone) Pure tone thresholds (HTL, MCL, UCL, SF, SF-Aided)
Number of curves in audiogram Max. 4 of each type
Audiogram views Dual, single, HL, SPL, top-view
Audiogram range Standard (8 kHz), high freq. (16 kHz)
13
Item Description
Standards supported IEC 60118-7; IEC 60118-15, ANSI S3.22
No. channels 2
Signal types Pure tone, warble tone, narrowband noise, white noise, speech-weighted noise, pink noise
Frequency range 125 – 16.000 Hz
Signal levels 40 to 100 dB SPL
Tolerance +/- 4 dB
Pure tone accuracy Within 0.2 %
Distortion Less than 1 %
Item Description
Operation mode Single side
Measurement types OSPL90, FOG, freq.-range, THD, Equiv. Input Noise, battery consumption, induction coil, AGC
Measurement views Output-SPL, Gain-dB, I/O
Diagram type Single, top-mode
Resolution 6, 12, 24 pins per octave
Level steps 5 dB
Diagram overlays Cursor lines with read out (level, frequency, diff)
Unity 3 HIA
Unity 3 dimensions
394 mm
330 mm
340 mm
340 mm 300 mm
394 mm
415 mm394 mm
135 mm
28 mm
117 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
340 mm
135 mm
300 mm 28 mm
117mm
415 mm
330 mm394 mm
14
www.siemens.com/hearing
Order No. A91SAT-02247-99C1-7600 | Printed in Germany | © 02.2014
Global Business UnitSiemens Audiologische Technik GmbHGebbertstrasse 125DE-91058 ErlangenGermanyPhone: +49 9131 308-0
Global Siemens HeadquartersSiemens AGWittelsbacherplatz 280333 MuenchenGermany
Global Siemens Healthcare HeadquartersSiemens AGHealthcare SectorHenkestrasse 12791052 ErlangenGermanyPhone: +49 9131 84-0www.siemens.com/healthcare
Legal ManufacturerSiemens Audiologische Technik GmbHGebbertstrasse 125DE-91058 ErlangenGermany
The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases and are subject to change without prior notice.
The required features should therefore be specifi ed in each individual case at the time of conclusion of the respective contract.