HDA Daily Start-up Check For CSC
Title:ProcedureP08-SE-006
DCM Update for WWN Procedure - Seagate
RevisionA
Page2 of 8
Title:DCM Update WWN Procedure - Seagate
Originator:KP Lim
Owner:Seagate
Prepared byName (in block letter)SignatureDate
Originator
Approved byName (in block letter)SignatureDate
Owner
Owners Department Head
Reviewed byName (in block letter)SignatureDate
Quality
Seagate Business Unit Manager
Revision History
RevDescriptionChange ByDate
ReleaseRef. No
AInitial ReleaseKC Chong18 March 2011-
1. Scope
This procedure is applicable to all Seagate products of Teleplan Penang.
2. Purpose
To establish Seagate DCM update WWN process in Teleplan Penang from Seagate to Teleplan production release.
3. Terms and definations
3.1 BE - Back End
3.2 ECR Enterprise Change Request
3.3 FCN Field Change Notice
3.4 DCM - Drive Configuration Manager
3.5 DCC Drive Customer Configuration
3.6 BOM Bill of Material
3.7 SBR Sub Build Group
3.8 S/N Serial Number
3.9 FC Fiber Channel
3.10 SAS Serial Attach SCSI
3.11 WWN World Wide Number4. Reference Documents
-5. Responsibilities
5.1 Product Engineer
5.1.1 Upon received WWN block from Seagate through email the WWN block will be immediately implement into DCM.
5.1.2 Update to tables: ID, BLOCK, PRODUCT, FACLITY, FILLED & CONTACT.5.2 BE Process Engineer
5.2.1 To ensure all WWN details and changes are matching according to customer specification.5.2.2 Process Engineer informs Product Engineer immediately if any discrepancy found during verification.5.3 Quality Engineer
5.3.1 To ensure the sample label details is matching with the change in WWN related document.
5.3.2 To make sure printing quality is good and all the information on the label has meet overall requirement per qualification plan.
5.3.3 To inform Product Engineer and BE Process Engineer immediately whenever there is any reject found during sample label verification and new label released.
6. Procedure
6.1 Upon received new WWN block from Seagate. 6.2 Login to http://www.sgtacr.com.my/dcmweb/dcm_manager_menu.asp,
6.3 Current DCM Manager Version is V3.16.0 (refer graphic 1) and DCMHUB is v3 (refer graphic 2).6.4 Then select the block received, SATA, SAS or FC block.
Graphic 1
Graphic 26.5 For SATA block received using DCM Manager V3.16.0 refer Graphic 3 and for DCMHUB v3 refer graphic 4 to key in NAA, ORG ID, BLOCK, PRODUCT, FACILITY, FILLED & CONTACT fields acoording to SATA block received. Next Serial field by default setting by system is 0.
Graphic 3
Graphic 46.6 For SAS block received using DCM Manager V3.16.0 refer Graphic 5 and for DCMHUB v3 refer graphic 6 to key in NAA, ORG ID, BLOCK, PRODUCT, FACILITY, FILLED & CONTACT fields acoording to SAS block received. Next Serial field by default setting by system is 0.
Graphic 5
Graphic 66.7 For FC block received using DCM Manager V3.16.0 refer Graphic 7 and for DCMHUB v3 refer graphic 8 to key in ORG ID, BLOCK, PRODUCT, FACILITY, FILLED & CONTACT fields acoording to FC block received. Next Serial field by default setting by system is 1.
Graphic 7
Graphic 86.8 BE Process Engineer to verify the WWN details.6.9 Inform Product Engineer immediately if any discrepancy found and correction taken by Product Engineer.7. Records
N/A