Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
GURU GOBIND SINGIIMEDICAL COLLEGE, tr'ARIDKOT. ("[JNJAB)- T51203.(Constituent Medical College of Baba Farid University of Health Sciences, Faridkot)
E-mail: Dr [email protected] Website: wryw.ggsmch.orqPhone: 01639-251111 Fax: 01639-2510:/0 GSTIN : 03AAAGG00G2R2ZG
No. Purchas e/ GGS|Z} 19 I " TSq Date: fla
Sub: Quotation for Supply of Bacteriological Incubator at this Institution.
Sealed quotations are invited for supply of Bacteriological Incubator on terms & conditionsgiven as under.
Sr. No. Name of the Item Qty Required
Bacteriological Incubator As per requirement
Snecifications :-
Internal dimension 605 mm x 605 mm x 605 mm , 224
litres
2. Outer body made up of mild steel sheet duly powder
coated and rust free
J. Inner chamber made of stainless steel SS 304 grade ,
mirror polished
4. Space between inner and outer chamber fitted withmineral wool for minimal heat dissipation
5. Door fitted with heavy duty hinges and door handle
ensuring there are no leakages through the door gasket
6. The door should have a mirror so that samples can be
viewed from outside.
7. Heating elements placed in the ribs and bottom and
sides for uniform heatdistribution
8. Synthetic door,gasket made up
9. Air ventildtorsto be provided on both sides.
10. Temperature range ambient +5 - 70.degree C
11 Temperature resolution 0.1 degree C
12. Temperature uniformity +0. 5
13. 3 Stainless steel ISS 304 grade ) perforated trays /adjustable as per user convenience
F:
W*u-\PurchaseVDec 2017 R\Quotation Call\Quot.Docx
Power supply 220 V - 230 V / S0 HZ
Heat load 1.5 I( /15.
16. rvrarns on / orr swtch provided with indicator in controlpanel.
17. rruvltretr wtrn a torcecl convection system I a separate
switch to turn fan on / off must be provided J
18. lvuuruprocessor Dased plD system , Digital display gfpresent value of temperature and set value oftemperature
19. Jarely qevrce / sultable thermostat and auto cut off toprevent overheating along with loyr, / high alarm taudio / visual Jthat alerts operator if any variation inset temperature.
20. rvrounreq on caster wheels tor easy portability
21 A ucrLulcafe ensunng 55 JU4 grade must be provided
22. LaurJraf,ton ceruflcate and operation manual must be
provide ( in English J
23. r D^ / L,E / IJIJ approved product
1nL+ r ue rnsLrument must be of above specifications and in agood condition.
25. urrslLe lnslarraflon and demonstration of product.
14
Terms & Conditions:
1. The material shourd be Good euarity and according to the requirement.2' The material should meet standards in Quality and irana / uake and Specifications should bementioned clearly.3' Supply should be F.o.R Destination at store G.G.s Medical college & Hospital Faridkot4' Rates quoted should not be more than those quoted to DGS&D url ury other central or StateGovt. Organizations.5' Payment will be made after getting satisfactory report from the concerned department.6' If the supply is not made within the stipulated periods then late delivery char[es 92% will beimposed on the total amount up to.delay of 30 days and thereaft er @4%for another 30 days.7. Taxes should be clearly mentionejd separately. --- \7
Note: onf Terms & Conditions mentioned on this Quotation wilt be considered for supply
You are requested to send your lowest bid in_sealed envelope, addressed to The pRINCIpAL, G.G.SMedical college, and FARIDKoT super scribing "quorarioN" fo. ,,Bacteriological rncubator ,,
on the top of the Envelope.
throu gh kTJ'3:lfl !T:ftri:: gif i:tl]rffi Lx Hi; ipa, o ffi c e .,
l, I f:s 0 0 p
t\\.Y-.^tv-7\l/
Pfincip{c4
F :\purchase Dec 20 1 7 R\euotation Cal tteuo'rOo jx