www.weil-mclain.com WTGO GOLD SERIES OIL BOILER Water with Tankless Heater | Chimney Vent | 86-295 MBH Series 3 | Efficiency 85-87% * * ENERGY STAR ® requires a minimum of 87% AFUE, which is only achieved by these models by reducing the burner rate and installing the optional vent damper kit. See Ratings chart on next page. * APPLICATIONS INCLUDE: Residential Light Commercial Multiple Boilers Radiant Heating ...And Much More HIGH EFFICIENCY CAST IRON BOILER Provides space and domestic hot water heating Durable cast iron heat exchanger design Made with Weil-McLain quality

WTGO Sales Flyer 0118.pdfNOTES: ** Add “P” for packaged boiler (WTGO-3 through WTGO-6 only). Add “A” for boiler only (WTGO-3 through WTGO-9). (1) ting (6) No. 2 fuel oil-Commercial

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • www.weil-mclain.com

    WTGO™GOLD SERIES OIL BOILER

    Water with Tankless Heater | Chimney Vent | 86-295 MBH Series 3 | Efficiency 85-87%*

    *ENERGY STAR® requires a minimum of 87% AFUE, which is only achieved by these models by reducing the burner rate and installing the optional

    vent damper kit. See Ratings chart on next page.

    *

    APPLICATIONS INCLUDE:

    ResidentialLight CommercialMultiple BoilersRadiant Heating

    ...And Much More

    HIGH EFFICIENCY CAST IRON BOILER

    ■ Provides space and domestic hot water heating

    ■ Durable cast iron heat exchanger design

    ■ Made with Weil-McLain quality

  • NOTES:** Add “P” for packaged boiler (WTGO-3 through WTGO-6 only). Add “A” for boiler only (WTGO-3 through WTGO-9).(1) No. 2 fuel oil-Commercial Standard Specification CS75-56. Heating value of oil-140,000 BTU/Gal.(2) Based on standard test procedures prescribed by the United States Department of Energy at combustion condition of 13 1/2% CO2 and -0.02” W.C. draft.(3) MBH refers to thousands of BTU per hour.(4) AHRI gross output.(5)Net AHRI ratings are based on net installed radiation adequate for the requirements of the building, including a piping and pickup allowance of 1.15-sufficient for normal conditions. Provide additional allowance only for unusual piping and pickup loads. (6) Tankless heater rating is in gallons of water per minute, heated from 40oF to 140oF with 200oF boiler water temperature-tested in accordance with I-W-H Testing and Rating Standard for Indirect Tankless Water Heaters Test with Boilers.

    ■ Factory Tested and Assembled Cast Iron Section Assembly (jacket and collector hood are not assembled on 7, 8 and 9 section blocks)

    ■ Tankless Heater (P-units) or Tankless Opening Cover Plate (A-units)

    ■ Insulated Steel Jacket■ Aluminized Steel Flue Collector

    Hood with Flue Cap on Top Outlet (convertible to rear outlet)

    ■ Swing-Away Burner Mounting Door■ Refractory Blanket and Target Wall

    in Combustion Area■ Circulator (Taco 007)-When Ordered ■ Comb. Temp. Controls, LWCO,

    Circulator Relay (all P-units/A-units ordered with tankless heater), and integrated service switch

    ■ Two Vent Pipe Brackets ■ Pressure / Temperature Gauge ■ 30 PSI ASME Relief Valve (boiler

    sections tested for 50 PSIG working pressure)

    ■ Drain Valve ■ Barometric Damper

    ■ High-Efficiency Flame-Retention Oil Burner (Beckett AFG, Carlin EZ or Riello). Specify 2-Stage Fuel Unit (optional) if Required

    ■ Vent Damper Kit ■ W-M 5 & 10 Year Homeowner

    Protection Plan ■ W-M Indirect-Fired Water Heaters

    OPTIONAL EQUIPMENT:

    Tapp

    ing

    Size

    Con

    trol

    B2

    E3

    HLN

    R1

    1 1/2

    1/2

    3/4

    3/4

    1/2

    3/4

    Alternate return - “A” units only

    Pressure/temperature gauge

    Drain valve

    High limit/circulator control

    Piping to expansion tank or automatic air vent

    Relief valve

    (inc

    hes)

    Loca

    tion

    A-WTGO FrontSide Back Intermediate

    DIMENSIONS STANDARD EQUIPMENT:

    Mod

    el

    P-W

    GO

    A-W

    GO

    Retu

    rn

    B L

    WTGO-3

    WTGO-3L

    WTGO-4

    WTGO-5

    WTGO-6

    WTGO-7

    WTGO-8

    WTGO-9

    Dimension (inches)

    1 1/4 (circulator flange)

    not applicable

    not applicable

    not applicable

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    1 1/2

    13 3/4

    16 7/8

    20

    23 1/8

    26 1/4

    32 1/2

    29 3/8

    16 7/8

    10 1/2

    13 5/8

    16 7/8

    20

    23 1/8

    29 3/8

    26 1/4

    13 1/2

    Supply “C” (inches)

    (inc

    hes)

    Num

    ber

    WT-14

    WT-14

    WT-14

    WT-14

    WT-14

    WT-20

    WT-20

    WT-20

    1/2

    1/2

    1/2

    1/2

    1/2

    1/2

    1/2

    1/2

    Inle

    t & O

    utle

    t(N

    PT)

    (in)

    3/4

    3/4

    3/4

    3/4

    3/4

    3/4

    3/4

    3/4

    Tem

    p C

    ontr

    ol(N

    PT)

    (in)

    Tankless Heater

    1 1/4 (circulator flange)

    1 1/4 (circulator flange)

    1 1/2 (circulator flange)

    1 1/2 (circulator flange)

    Mod

    el**

    Hea

    ting

    Net

    Rat

    ingS

    Dra

    ft L

    oss

    Thro

    ugh

    Roun

    d (i

    n.)

    Hei

    ght (

    ft.)

    App

    rox.

    Shi

    ppin

    g

    (MB

    H)

    (2)

    (3)

    (MBH

    ) (3

    ) (5

    )

    Boi

    ler (

    in w

    /c)

    WTGO-3LR 98 75

    WTGO-3RD 112 85

    WTGO-4RD 140 107

    WTGO-5RD 168 129

    WTGO-6RD 196 150

    WTGO-7RD 224 171

    WTGO-8 322 231 (4)WTGO-9 357 257 (4)

    GPH

    (1)

    Minimum Chimney Size

    Wei

    ght (

    Lbs)

    Rect

    angu

    lar (

    in.)

    ENER

    GY

    STA

    R*

    WTGO-3L 133 99

    WTGO-3 133 100

    WTGO-4 168 126

    WTGO-5 203 152

    WTGO-6 245 184

    WTGO-7

    540

    595

    645

    760

    860

    930

    1,0301,135

    540

    595

    645

    760

    860

    930

    0.70

    0.80

    1.00

    1.20

    1.40

    1.60

    2.302.55

    0.95

    0.95

    1.20

    1.45

    1.75

    2.00 280

    86

    98

    123

    148

    173

    197

    266295

    114

    115

    145

    175

    212

    242 210

    .010

    .010

    .010

    .015

    .015

    .015

    .025

    .030

    .010

    .020

    .010

    .015

    .015

    .015

    8X8

    8X8

    8X8

    8X8

    8X8

    8X8

    8X12

    8X12

    8X8

    8X8

    8X8

    8X8

    8X8

    8X8

    6

    6

    6

    7

    7

    8

    88

    6

    6

    6

    7

    7

    8

    15

    15

    15

    15

    15

    15

    2020

    15

    15

    15

    15

    15

    15

    *

    *

    *

    *

    *

    MB

    H (

    3)

    AFU

    E

    86.4

    87.0

    87.0

    87.0

    87.0

    87.0

    --

    85.0

    85.3

    85.0

    85.0

    85.0

    85.0

    BurnerInput

    Rating AHRI Certified Ratings

    Cap

    acity

    Tank

    less

    Hea

    ter

    3.25

    3.00

    3.75

    4.00

    4.25

    5.50

    5.756.00

    3.25

    3.00

    3.75

    4.00

    4.25

    5.50

    Dra

    w R

    atin

    g (6

    )

    Inte

    rmitt

    ent

    WM1801_BRO_049_WTGO

    RATINGS

    Tapp

    ings

    *ENERGY STAR® compliant with Version 3.0 Boiler Specification of 87% AFUE only when installed at the reduced burner rate (R) and with the optional vent damper kit (D). Burners shipped with standard rate nozzle, reduced rates achieved through nozzle change-refer to burner instructions or boiler’s rating label for correct selection.

    *

    In the interest of continual improvements in product and performance, Weil-McLain reserves the right to change specifications without notice.

    345/8

    201/4