20
WS Westin Ltd CACHE 520 with Internal Motor 61.8 58 kWh/annum 65/2014 CACHE 520 Built In Unit extractor with Internal Motor Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014 Supplier WS Westin Ltd Model Identifier CACHE 520 Product Data Symbol Unit Value Annual Energy Consumption AEC hood KWh/a 57.9 Energy Efficiency Class A Fluid Dynamic Efficiency FDE hood 30.9 Fluid Dynamic Efficiency Class A Light Efficiency LE hood lux/W 40.0 Light Efficiency Class A Grease Filtering Efficiency GFE hood % 90 Grease Filtering Efficiency Class B Minimum Airflow in Normal Use m 3 /hr 245.5 Maximum Airflow in Normal Use m 3 /hr 531.8 Airflow at Intensive Setting m 3 /hr 761.0 A-weighted Sound Power at Minimum Speed dB(A) 46 A-weighted Sound Power at Maximum Speed dB(A) 62 A-weighted Sound Power at Intensive Speed dB(A) 70 Power Consumption in Off Mode Po W 0.00 Power Consumption in Standby Mode Ps W 0.37 Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014 Time Increase Factor f 0.9 Energy Efficiency Index EEI hood % 53.2 Measured Air Flow at Best Efficiency Point Q BEP m 3 /hr 414.3 Measured Air Pressure at Best Efficiency Point P BEP Pa 443 Maximum Air Flow Q Max m 3 /hr 790.3 Measured Electric Power Input at Best Efficiency Point W BEP W 164.8 Nominal Power of Lighting System W L W 5.2 Average Illumination of Lighting System on cooktop E MIDDLE lux 208 Products manufactured and tested in accordance with EU harmonised standards: Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO 5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product: When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes and cooking vapours require you to do so. The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the duct length and number of bends are minimised. Follow all recommendations relating to installation, use and maintenance described in the product manual. ENERGYDOC - CACHE 520 - V1 P1

WS Westin Ltd Energy Efficiency Class A Fluid Dynamic ... · Energy Efficiency Class A Fluid ... Measured Air Flow at Best Efficiency Point QBEP m 3/hr 414.3 Measured Air Pressure

Embed Size (px)

Citation preview

WS Westin Ltd CACHE 520with Internal Motor

61.8

58 kWh/annum

65/2014

CACHE 520 Built In Unit extractor with Internal Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 520

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 57.9

Energy Efficiency Class A

Fluid Dynamic Efficiency FDEhood 30.9

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 40.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 245.5

Maximum Airflow in Normal Use m3/hr 531.8

Airflow at Intensive Setting m3/hr 761.0

A-weighted Sound Power at Minimum Speed dB(A) 46

A-weighted Sound Power at Maximum Speed dB(A) 62

A-weighted Sound Power at Intensive Speed dB(A) 70

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 0.9

Energy Efficiency Index EEIhood % 53.2

Measured Air Flow at Best Efficiency Point QBEP m3/hr 414.3

Measured Air Pressure at Best Efficiency Point PBEP Pa 443

Maximum Air Flow QMax m3/hr 790.3

Measured Electric Power Input at Best Efficiency Point WBEP W 164.8

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 208

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 520 - V1 P1

WS Westin Ltd CACHE 700with Internal Motor

61.8

58 kWh/annum

65/2014

CACHE 700 Built In Unit extractor with Internal Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 700

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 57.9

Energy Efficiency Class A

Fluid Dynamic Efficiency FDEhood 30.9

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 35.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 245.5

Maximum Airflow in Normal Use m3/hr 531.8

Airflow at Intensive Setting m3/hr 761.0

A-weighted Sound Power at Minimum Speed dB(A) 46

A-weighted Sound Power at Maximum Speed dB(A) 62

A-weighted Sound Power at Intensive Speed dB(A) 70

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 0.9

Energy Efficiency Index EEIhood % 53.2

Measured Air Flow at Best Efficiency Point QBEP m3/hr 414.3

Measured Air Pressure at Best Efficiency Point PBEP Pa 443

Maximum Air Flow QMax m3/hr 790.3

Measured Electric Power Input at Best Efficiency Point WBEP W 164.8

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 182

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 700 - V1 P1

WS Westin Ltd CACHE 800with Internal Motor

62.3

54 kWh/annum

65/2014

CACHE 800 Built In Unit extractor with Internal Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 800

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 53.7

Energy Efficiency Class A

Fluid Dynamic Efficiency FDEhood 32.1

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 30.2

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 237.5

Maximum Airflow in Normal Use m3/hr 507.4

Airflow at Intensive Setting m3/hr 771.5

A-weighted Sound Power at Minimum Speed dB(A) 44

A-weighted Sound Power at Maximum Speed dB(A) 62

A-weighted Sound Power at Intensive Speed dB(A) 71

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 0.8

Energy Efficiency Index EEIhood % 47.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 423.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 466

Maximum Air Flow QMax m3/hr 787.4

Measured Electric Power Input at Best Efficiency Point WBEP W 171.0

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 157

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 800 - V1 P1

WS Westin Ltd CACHE 900with Internal Motor

62.3

54 kWh/annum

65/2014

CACHE 900 Built In Unit extractor with Internal Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 900

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 53.7

Energy Efficiency Class A

Fluid Dynamic Efficiency FDEhood 32.1

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 27.3

Light Efficiency Class B

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 237.5

Maximum Airflow in Normal Use m3/hr 507.4

Airflow at Intensive Setting m3/hr 771.5

A-weighted Sound Power at Minimum Speed dB(A) 44

A-weighted Sound Power at Maximum Speed dB(A) 62

A-weighted Sound Power at Intensive Speed dB(A) 71

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 0.8

Energy Efficiency Index EEIhood % 47.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 423.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 466

Maximum Air Flow QMax m3/hr 787.4

Measured Electric Power Input at Best Efficiency Point WBEP W 171.0

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 142

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 900 - V1 P1

WS Westin Ltd CACHE 1100with Internal Motor

62.3

56 kWh/annum

65/2014

CACHE 1100 Built In Unit extractor with Internal Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 1100

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 55.6

Energy Efficiency Class A

Fluid Dynamic Efficiency FDEhood 32.1

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 28.3

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 237.5

Maximum Airflow in Normal Use m3/hr 507.4

Airflow at Intensive Setting m3/hr 771.5

A-weighted Sound Power at Minimum Speed dB(A) 44

A-weighted Sound Power at Maximum Speed dB(A) 62

A-weighted Sound Power at Intensive Speed dB(A) 71

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 0.8

Energy Efficiency Index EEIhood % 48.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 423.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 466

Maximum Air Flow QMax m3/hr 787.4

Measured Electric Power Input at Best Efficiency Point WBEP W 171.0

Nominal Power of Lighting System WL W 7.8

Average Illumination of Lighting System on cooktop EMIDDLE lux 221

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 1100 - V1 P1

WS Westin Ltd CACHE 520 EMwith SEM2 Remote Wall Motor

47.1

82 kWh/annum

65/2014

CACHE 520 EM Built In Unit extractor with SEM2 Remote Wall Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 520 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 81.8

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 25.9

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 40.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 398.7

Maximum Airflow in Normal Use m3/hr 584.0

Airflow at Intensive Setting m3/hr 790.0

A-weighted Sound Power at Minimum Speed dB(A) 36

A-weighted Sound Power at Maximum Speed dB(A) 47

A-weighted Sound Power at Intensive Speed dB(A) 59

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.1

Energy Efficiency Index EEIhood % 65.5

Measured Air Flow at Best Efficiency Point QBEP m3/hr 479.2

Measured Air Pressure at Best Efficiency Point PBEP Pa 378

Maximum Air Flow QMax m3/hr 854.2

Measured Electric Power Input at Best Efficiency Point WBEP W 194.2

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 208

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 520 EM - V1 P1

WS Westin Ltd CACHE 520 EMwith SEM1 Remote Inline Motor

44dB

63 kWh/annum

65/2014

CACHE 520 EM Built In Unit extractor with SEM1 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 520 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 62.5

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 28.3

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 40.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 225.3

Maximum Airflow in Normal Use m3/hr 417.9

Airflow at Intensive Setting m3/hr 725.0

A-weighted Sound Power at Minimum Speed dB(A) 29

A-weighted Sound Power at Maximum Speed dB(A) 44

A-weighted Sound Power at Intensive Speed dB(A) 55

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 58.6

Measured Air Flow at Best Efficiency Point QBEP m3/hr 350.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 468

Maximum Air Flow QMax m3/hr 755.8

Measured Electric Power Input at Best Efficiency Point WBEP W 160.9

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 208

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 520 EM - V1 P2

WS Westin Ltd CACHE 520 EMwith SEM8 Remote Inline Motor

41.8

91 kWh/annum

65/2014

CACHE 520 EM Built In Unit extractor with SEM8 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 520 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 91.2

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 26.6

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 40.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 376.9

Maximum Airflow in Normal Use m3/hr 558.0

Airflow at Intensive Setting m3/hr 900.0

A-weighted Sound Power at Minimum Speed dB(A) 33

A-weighted Sound Power at Maximum Speed dB(A) 42

A-weighted Sound Power at Intensive Speed dB(A) 62

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 60.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 486.1

Measured Air Pressure at Best Efficiency Point PBEP Pa 471

Maximum Air Flow QMax m3/hr 981.8

Measured Electric Power Input at Best Efficiency Point WBEP W 239.4

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 208

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 520 EM - V1 P3

WS Westin Ltd CACHE 700 EMwith SEM2 Remote Wall Motor

47.1

82 kWh/annum

65/2014

CACHE 700 EM Built In Unit extractor with SEM2 Remote Wall Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 700 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 81.8

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 25.9

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 35.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 398.7

Maximum Airflow in Normal Use m3/hr 584.0

Airflow at Intensive Setting m3/hr 790.0

A-weighted Sound Power at Minimum Speed dB(A) 36

A-weighted Sound Power at Maximum Speed dB(A) 47

A-weighted Sound Power at Intensive Speed dB(A) 59

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.1

Energy Efficiency Index EEIhood % 65.5

Measured Air Flow at Best Efficiency Point QBEP m3/hr 479.2

Measured Air Pressure at Best Efficiency Point PBEP Pa 378

Maximum Air Flow QMax m3/hr 854.2

Measured Electric Power Input at Best Efficiency Point WBEP W 194.2

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 182

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 700 EM - V1 P1

WS Westin Ltd CACHE 700 EMwith SEM1 Remote Inline Motor

44dB

63 kWh/annum

65/2014

CACHE 700 EM Built In Unit extractor with SEM1 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 700 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 62.5

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 28.3

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 35.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 225.3

Maximum Airflow in Normal Use m3/hr 417.9

Airflow at Intensive Setting m3/hr 725.0

A-weighted Sound Power at Minimum Speed dB(A) 29

A-weighted Sound Power at Maximum Speed dB(A) 44

A-weighted Sound Power at Intensive Speed dB(A) 55

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 58.6

Measured Air Flow at Best Efficiency Point QBEP m3/hr 350.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 468

Maximum Air Flow QMax m3/hr 755.8

Measured Electric Power Input at Best Efficiency Point WBEP W 160.9

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 182

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 700 EM - V1 P2

WS Westin Ltd CACHE 700 EMwith SEM8 Remote Inline Motor

41.8

91 kWh/annum

65/2014

CACHE 700 EM Built In Unit extractor with SEM8 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 700 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 91.2

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 26.6

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 35.0

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 90

Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 376.9

Maximum Airflow in Normal Use m3/hr 558.0

Airflow at Intensive Setting m3/hr 900.0

A-weighted Sound Power at Minimum Speed dB(A) 33

A-weighted Sound Power at Maximum Speed dB(A) 42

A-weighted Sound Power at Intensive Speed dB(A) 62

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 60.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 486.1

Measured Air Pressure at Best Efficiency Point PBEP Pa 471

Maximum Air Flow QMax m3/hr 981.8

Measured Electric Power Input at Best Efficiency Point WBEP W 239.4

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 182

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 700 EM - V1 P3

WS Westin Ltd CACHE 800 EMwith SEM2 Remote Wall Motor

47.1

82 kWh/annum

65/2014

CACHE 800 EM Built In Unit extractor with SEM2 Remote Wall Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 800 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 81.8

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 25.9

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 30.2

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 398.7

Maximum Airflow in Normal Use m3/hr 584.0

Airflow at Intensive Setting m3/hr 790.0

A-weighted Sound Power at Minimum Speed dB(A) 36

A-weighted Sound Power at Maximum Speed dB(A) 47

A-weighted Sound Power at Intensive Speed dB(A) 59

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.1

Energy Efficiency Index EEIhood % 65.5

Measured Air Flow at Best Efficiency Point QBEP m3/hr 479.2

Measured Air Pressure at Best Efficiency Point PBEP Pa 378

Maximum Air Flow QMax m3/hr 854.2

Measured Electric Power Input at Best Efficiency Point WBEP W 194.2

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 157

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 800 EM - V1 P1

WS Westin Ltd CACHE 800 EMwith SEM1 Remote Inline Motor

44dB

63 kWh/annum

65/2014

CACHE 800 EM Built In Unit extractor with SEM1 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 800 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 62.5

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 28.3

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 30.2

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 225.3

Maximum Airflow in Normal Use m3/hr 417.9

Airflow at Intensive Setting m3/hr 725.0

A-weighted Sound Power at Minimum Speed dB(A) 29

A-weighted Sound Power at Maximum Speed dB(A) 44

A-weighted Sound Power at Intensive Speed dB(A) 55

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 58.6

Measured Air Flow at Best Efficiency Point QBEP m3/hr 350.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 468

Maximum Air Flow QMax m3/hr 755.8

Measured Electric Power Input at Best Efficiency Point WBEP W 160.9

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 157

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 800 EM - V1 P2

WS Westin Ltd CACHE 800 EMwith SEM8 Remote Inline Motor

41.8

91 kWh/annum

65/2014

CACHE 800 EM Built In Unit extractor with SEM8 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 800 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 91.2

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 26.6

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 30.2

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 376.9

Maximum Airflow in Normal Use m3/hr 558.0

Airflow at Intensive Setting m3/hr 900.0

A-weighted Sound Power at Minimum Speed dB(A) 33

A-weighted Sound Power at Maximum Speed dB(A) 42

A-weighted Sound Power at Intensive Speed dB(A) 62

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 60.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 486.1

Measured Air Pressure at Best Efficiency Point PBEP Pa 471

Maximum Air Flow QMax m3/hr 981.8

Measured Electric Power Input at Best Efficiency Point WBEP W 239.4

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 157

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 800 EM - V1 P3

WS Westin Ltd CACHE 900 EMwith SEM2 Remote Wall Motor

47.1

82 kWh/annum

65/2014

CACHE 900 EM Built In Unit extractor with SEM2 Remote Wall Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 900 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 81.8

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 25.9

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 27.3

Light Efficiency Class B

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 398.7

Maximum Airflow in Normal Use m3/hr 584.0

Airflow at Intensive Setting m3/hr 790.0

A-weighted Sound Power at Minimum Speed dB(A) 36

A-weighted Sound Power at Maximum Speed dB(A) 47

A-weighted Sound Power at Intensive Speed dB(A) 59

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.1

Energy Efficiency Index EEIhood % 65.5

Measured Air Flow at Best Efficiency Point QBEP m3/hr 479.2

Measured Air Pressure at Best Efficiency Point PBEP Pa 378

Maximum Air Flow QMax m3/hr 854.2

Measured Electric Power Input at Best Efficiency Point WBEP W 194.2

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 142

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 900 EM - V1 P1

WS Westin Ltd CACHE 900 EMwith SEM1 Remote Inline Motor

44dB

63 kWh/annum

65/2014

CACHE 900 EM Built In Unit extractor with SEM1 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 900 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 62.5

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 28.3

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 27.3

Light Efficiency Class B

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 225.3

Maximum Airflow in Normal Use m3/hr 417.9

Airflow at Intensive Setting m3/hr 725.0

A-weighted Sound Power at Minimum Speed dB(A) 29

A-weighted Sound Power at Maximum Speed dB(A) 44

A-weighted Sound Power at Intensive Speed dB(A) 55

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 58.6

Measured Air Flow at Best Efficiency Point QBEP m3/hr 350.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 468

Maximum Air Flow QMax m3/hr 755.8

Measured Electric Power Input at Best Efficiency Point WBEP W 160.9

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 142

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 900 EM - V1 P2

WS Westin Ltd CACHE 900 EMwith SEM8 Remote Inline Motor

41.8

91 kWh/annum

65/2014

CACHE 900 EM Built In Unit extractor with SEM8 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 900 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 91.2

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 26.6

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 27.3

Light Efficiency Class B

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 376.9

Maximum Airflow in Normal Use m3/hr 558.0

Airflow at Intensive Setting m3/hr 900.0

A-weighted Sound Power at Minimum Speed dB(A) 33

A-weighted Sound Power at Maximum Speed dB(A) 42

A-weighted Sound Power at Intensive Speed dB(A) 62

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 60.9

Measured Air Flow at Best Efficiency Point QBEP m3/hr 486.1

Measured Air Pressure at Best Efficiency Point PBEP Pa 471

Maximum Air Flow QMax m3/hr 981.8

Measured Electric Power Input at Best Efficiency Point WBEP W 239.4

Nominal Power of Lighting System WL W 5.2

Average Illumination of Lighting System on cooktop EMIDDLE lux 142

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 900 EM - V1 P3

WS Westin Ltd CACHE 1100 EMwith SEM2 Remote Wall Motor

47.1

84 kWh/annum

65/2014

CACHE 1100 EM Built In Unit extractor with SEM2 Remote Wall Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 1100 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 83.7

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 25.9

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 28.3

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 398.7

Maximum Airflow in Normal Use m3/hr 584.0

Airflow at Intensive Setting m3/hr 790.0

A-weighted Sound Power at Minimum Speed dB(A) 36

A-weighted Sound Power at Maximum Speed dB(A) 47

A-weighted Sound Power at Intensive Speed dB(A) 59

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.1

Energy Efficiency Index EEIhood % 66.2

Measured Air Flow at Best Efficiency Point QBEP m3/hr 479.2

Measured Air Pressure at Best Efficiency Point PBEP Pa 378

Maximum Air Flow QMax m3/hr 854.2

Measured Electric Power Input at Best Efficiency Point WBEP W 194.2

Nominal Power of Lighting System WL W 7.8

Average Illumination of Lighting System on cooktop EMIDDLE lux 221

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 1100 EM - V1 P1

WS Westin Ltd CACHE 1100 EMwith SEM1 Remote Inline Motor

44dB

64 kWh/annum

65/2014

CACHE 1100 EM Built In Unit extractor with SEM1 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 1100 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 64.4

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 28.3

Fluid Dynamic Efficiency Class A

Light Efficiency LEhood lux/W 28.3

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 225.3

Maximum Airflow in Normal Use m3/hr 417.9

Airflow at Intensive Setting m3/hr 725.0

A-weighted Sound Power at Minimum Speed dB(A) 29

A-weighted Sound Power at Maximum Speed dB(A) 44

A-weighted Sound Power at Intensive Speed dB(A) 55

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 59.6

Measured Air Flow at Best Efficiency Point QBEP m3/hr 350.7

Measured Air Pressure at Best Efficiency Point PBEP Pa 468

Maximum Air Flow QMax m3/hr 755.8

Measured Electric Power Input at Best Efficiency Point WBEP W 160.9

Nominal Power of Lighting System WL W 7.8

Average Illumination of Lighting System on cooktop EMIDDLE lux 221

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 1100 EM - V1 P2

WS Westin Ltd CACHE 1100 EMwith SEM8 Remote Inline Motor

41.8

93 kWh/annum

65/2014

CACHE 1100 EM Built In Unit extractor with SEM8 Remote Inline Motor

Product fiche compliant to Commission Delegate REGULATION (EU) No 65/2014

Supplier WS Westin Ltd

Model Identifier CACHE 1100 EM

Product Data Symbol Unit Value

Annual Energy Consumption AEChood KWh/a 93.1

Energy Efficiency Class B

Fluid Dynamic Efficiency FDEhood 26.6

Fluid Dynamic Efficiency Class B

Light Efficiency LEhood lux/W 28.3

Light Efficiency Class A

Grease Filtering Efficiency GFEhood % 91.7000000

00000003 Grease Filtering Efficiency Class B

Minimum Airflow in Normal Use m3/hr 376.9

Maximum Airflow in Normal Use m3/hr 558.0

Airflow at Intensive Setting m3/hr 900.0

A-weighted Sound Power at Minimum Speed dB(A) 33

A-weighted Sound Power at Maximum Speed dB(A) 42

A-weighted Sound Power at Intensive Speed dB(A) 62

Power Consumption in Off Mode Po W 0.00

Power Consumption in Standby Mode Ps W 0.37

Additional data compliant to Commission Delegate REGULATION (EU) No 66/2014

Time Increase Factor f 1.0

Energy Efficiency Index EEIhood % 61.5

Measured Air Flow at Best Efficiency Point QBEP m3/hr 486.1

Measured Air Pressure at Best Efficiency Point PBEP Pa 471

Maximum Air Flow QMax m3/hr 981.8

Measured Electric Power Input at Best Efficiency Point WBEP W 239.4

Nominal Power of Lighting System WL W 7.8

Average Illumination of Lighting System on cooktop EMIDDLE lux 221

Products manufactured and tested in accordance with EU harmonised standards:

Safety: CEI/EN 60335-1; CEI/EN 60335-2-31, CEI/EN 62233. Performance: CEI/EN 61591; ISO 5167-1; ISO 5167-3; ISO

5168; CEI/EN 60704-1; CEI/EN 60704-2-13; ISO 3741; EN 50564; CEI 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;

CISPR 14-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3. Suggestions for reducing the environmental impact of this product:

When you start cooking run the extractor at the lowest speed setting, only increasing the motor speed when fumes

and cooking vapours require you to do so.

The appliance works more efficiently the shorter and straighter your duct run. Design your installation so that the

duct length and number of bends are minimised.

Follow all recommendations relating to installation, use and maintenance described in the product manual.

ENERGYDOC - CACHE 1100 EM - V1 P3