WR_TS02_E1_0 ZXWR Node B Maintenance 86

Embed Size (px)

DESCRIPTION

WR_TS02_E1_0 ZXWR Node B Maintenance 86

Citation preview

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]

  • Contents

    About this Manual Error! Bookmark not defined.

    Purpose Error! Bookmark not defined.

    Intended Audience Error! Bookmark not defined.

    Prerequisite Skill and Knowledge Error! Bookmark not defined.

    What is in This Manual Error! Bookmark not defined.

    Related Documentation Error! Bookmark not defined.

    Conventions Error! Bookmark not defined.

    How to Get in Touch Error! Bookmark not defined.

    Chapter 1 1

    Chapter Name Error! Bookmark not defined.

    Section 1 (optional) Error! Bookmark not defined.

    Topic 1 Error! Bookmark not defined.

    Topic 2 Error! Bookmark not defined.

    Section 2 (optional) Error! Bookmark not defined.

    Topic 3 Error! Bookmark not defined.

    Topic 4 Error! Bookmark not defined.

    Chapter 2 Error! Bookmark not defined.

    Chapter 3 Error! Bookmark not defined.

    Chapter 4 Error! Bookmark not defined.

    Chapter 5 Error! Bookmark not defined.

    Chapter 6 Error! Bookmark not defined.

    Chapter 7 Error! Bookmark not defined.

    Chapter 8 Error! Bookmark not defined.

    Chapter 9 Error! Bookmark not defined.

    Chapter 10 Error! Bookmark not defined.

    Chapter 11 Error! Bookmark not defined.

    Chapter 12 Error! Bookmark not defined.

    Appendix A 79

    Index Error! Bookmark not defined.

  • Glossary Error! Bookmark not defined.

    Figures Error! Bookmark not defined.

    Tables Error! Bookmark not defined.

  • Confidential and Proprietary Information of ZTE CORPORATION 1

    C h a p t e r 1

    Maintenance Overview

    This chapter introduces common maintenance types, maintenance principles and analysis methods and provides precautions for routine maintenance.

    Maintenance Description

    Maintenance Requirements

    Maintenance personnel must receive systematic training to be qualified in system maintenance, master fundamentals of ZXWR B09, and know overall structure and functions of each board, in addition to some knowledge about network optimization and network maintenance.

    Maintenance Principles This section introduces what maintenance personnel must pay attention to in ZXWR B09 maintenance. Any operation against following principles may have a negative impact on system operation.

    Right Management

    Assign personnel-specific usernames and passwords for system login, operation and maintenance, to restrict operation rights of maintenance individuals and find operation history through system logs in case of system malfunction.

    Different users are able to perform different groups of operations, depending on their levels and rights. Operation and

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    2 Confidential and Proprietary Information of ZTE CORPORATION

    maintenance software classifies operators into four levels, root user, advanced user, medium-level user, and ordinary user in descending order of rights.

    1. Root user, with highest level of right, can perform any operations, including creating users, modifying user information, deleting users, setting rights and modifying system configuration. Change initial password of root user immediately after logging in to the system, for security of the system

    2. Advanced user has the same rights as a root user, except that it cannot manage user accounts, add/delete boards and add/delete local cells.

    3. Medium-level user, with basic viewing right, can view alarm and system information. In addition, a medium-level user can only perform limited types of configuration operations.

    4. Ordinary user, with lowest right, can only view information rather than perform any configuration operation.

    Caution

    Use right management function to set ordinary equipment maintenance personnel as medium-level users.

    Do not log into the system as root user unless absolutely necessary.

    Do not change network settings of NMS server and Client.

    Do not run and operate any other programs not related to operation and maintenance on NMS server or Client.

    Follow general principles of network management to guard against any virus.

    Data Observation

    Caution

    Perform data observation operations carefully with large quantities of data to report, including signaling tracing, running information observation, all users of service observation, and alarm refreshing. Excessive data report during data observation may cause system breakdown in extreme cases.

    Caution

    Select appropriate time (low traffic period) for data observation operation, take appropriate measures, save results in time and clean temporary data in time.

  • Chapter 1 Maintenance Overview

    Confidential and Proprietary Information of ZTE CORPORATION 3

    Data Modification

    Caution

    Take care in modifying data, particularly wireless data.

    Observe carefully whether there is any effect on system operation after modifying data.

    Caution

    Be sure to perform backup before modifying any data, to ensure rapid restoration when any problem occurs.

    Do not perform data synchronization at rush hours (at 10 AM or 5 PM, Time varies from place to place).

    Do not modify foreground database during daytime.

    Data Synchronization

    Caution

    Be sure to backup data before modifying configuration.

    Caution

    Do not perform data synchronization in daytime unless necessary.

    Check operation log to identify the source if finding any data of an unknown source.

    Man-machine Commands

    Caution

    Be careful in using commands that lead to foreground actions, including restart, reset, changeover, save, hardware test, software download and cell block/unblock.

    Do not delete current alarms and history alarms unless absolutely necessary.

    Be sure to lock background man-machine interface after maintenance personnel leave operation and maintenance console, to avoid any accidents.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    4 Confidential and Proprietary Information of ZTE CORPORATION

    Board Operations

    Caution

    Do not reset a board, plug/unplug it or power it off unless absolutely necessary.

    Prepare spare board before replacing a board. Make sure there are sufficient technicians present for unexpected emergencies in the case of major operations, such as changing versions of important boards, or plugging, unplugging and replacing key boards. Maintenance personnel working on boards in the foreground must have support from background personnel.

    Caution:

    Always wear an antistatic wrist strap before operating boards on the rack and connect it to the rack before touching a board.

    Touch a metal object first to release static electricity on hands.

    Reduce power gradually (to change users in conversation or in network access and to prevent users off-conversation from accessing) when replacing LPA (Linear Power Amplifier).

    Update

    Caution

    Perform upgrade at midnight when there is low traffic.

    Keep contact information available for relevant personnel (like transmission and power supply) to get their timely assistance when required.

    Formulate upgrade plan in advance, covering all emergency measures.

    Do not change procedures set forth in the plan, unless necessary.

    Inform supervisors before upgrading for necessary technical support.

    Assign a person to closely monitor the system for any faults occurring since the upgrade.

  • Chapter 1 Maintenance Overview

    Confidential and Proprietary Information of ZTE CORPORATION 5

    Maintenance Classification Maintenance falls into routine maintenance, notification message handling, alarm message handling and troubleshooting, by contents.

    1. Routine maintenance

    Routine maintenance refers to checking equipment running status periodically. It is to find out and handle problems in time to prevent potential damage or fault.

    2. Notification message handling

    Notification message handling is to analyze all kinds of notifications during running of the system, to judge whether anything is abnormal and to take appropriate measures.

    3. Alarm message handling

    Alarm message handling is to analyze different alarm messages during running of the equipment, to judge equipment running condition and to take appropriate measures.

    4. Troubleshooting

    Troubleshooting is to analyze, handle and remove detected faults.

    Analysis Methods Common maintenance analysis methods:

    Analysis of indicator status

    Analysis of signalling tracing

    Analysis of alarm logs

    Analysis through instruments and meters

    Comparison by replacement

    Others

    Indicator Status Analysis

    Analyze running of a board by statuses of its indicators.

    Boards need frequent observation, for the ZXWR B09, are: control clock switching board CCS, Iub-ATM interface board IIA, baseband processing board BP and transceiver unit TRXU.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    6 Confidential and Proprietary Information of ZTE CORPORATION

    Signaling Tracing Analysis

    Signaling tracing analysis is to check whether signaling flow is correct. All services have their own signaling flows. It is acceptable to diagnose system problems according to experience by viewing differences between current flow and correct flow, when a service is abnormal.

    Important workflow, for the ZXWR B09, includes: cell setup, common transmission channel setup, paging, random access, system information update and wireless link setup.

    Alarm Logs Analysis

    Alarm log analysis is to query history alarms and current alarms of the system at NM interface, and to analyze and determine running status of the equipment. Instruments and Meters Analysis

    Commonly-used instruments and meters in routine maintenance include signaling meters, line testers and power meters.

    Signaling Meter Analysis

    Signaling meter is to monitor signaling interaction between Node B and RNC in real time. Figure 1 shows the connection mode of signaling meter with the equipment.

  • Chapter 1 Maintenance Overview

    Confidential and Proprietary Information of ZTE CORPORATION 7

    FI G U R E 1 AP P L I C AT I O N O F S I G N AL L I N G M E T E R AT RNS

    RNC

    RNC

    Node B

    Node B

    Laptop computer

    1

    2

    90%

    100%

    10%

    100%90

    %Optical splitter

    Signaling meter

    10%

    RNC and Node B setup several AAL5 links to bear ALCAP, common NBAP, dedicated NBAP and IPoA after powering on the equipment. It is acceptable to query VPI and VCI corresponding to each AAL5 link from OMC background man-machine interface. It is also acceptable to monitor signaling of corresponding AAL5 link after configuring appropriate VPI and VCI on signaling meter.

    Set up appropriate VPI, VCI and CID on signaling meter, when AAL2 bears common transport channels (FACH, PCH, and RACH) and DCH and observes AAL2 signaling. Similarly, it is acceptable to query its signaling from WOMCR background man-machine interface. Signaling meter can resolve RRC message of Uu interface and non-access layer messages.

    Signaling meter analysis allows monitoring signaling flows between Node B, RNC and UE in real time and saving results.

    Line Tester Measurement

    Line tester supports:

    1. To measure information of common channels.

    2. To measure related items in coverage area, such as locations, signal strength and signal quality.

    3. To measure energy of each synchronization code in each timeslot on synchronization channel.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    8 Confidential and Proprietary Information of ZTE CORPORATION

    4. To measure channel power.

    5. To measure scramble of the cell.

    Power Meter Measurement

    Power meter is to measure output power of TRXU and LPA and to judge whether TRXU and LPA are working normally.

    Replacement Analysis

    Replace a board module or possibly a faulty connection cable with a normal board module or connection cable of same type, and observe whether the fault is recovered after the replacement.

    Use the following replacement analysis methods to rectify faulty boards or a subsystem.

    Active/Standby Switchover

    This method applies to active and standby boards configured on the ZXWR B09 rack, such as CCS.

    Operate on background man-machine interface or press active/standby switchover key on front panel of the board to reset the board and to trigger active/standby switchover function.

    Perform a switchover again when traffic is light and observe whether system is normal if the system recovers after active/standby switchover. Circuit or interface of currently active board may fail if system is not normal. Replace it and perform further tests.

    Board Resource Block

    This method applies to BP.

    Block, possibly a faulty BP and check the working status of the system. Fault resides in BP or interface of the board if system recovers. Replace the board, unblock it and perform further tests.

    Slot Exchange

    This method applies to BP and TRXU. There is need to configure multiple BPs and TRUXs on the ZXWR B09 rack.

  • Chapter 1 Maintenance Overview

    Confidential and Proprietary Information of ZTE CORPORATION 9

    Exchange slot of a normal board with a possibly faulty board, and check working states of boards to determine whether fault resides in the board or interface of the board.

    Board Replacement

    This method applies to EMU and TRXU configured for single carrier and single fan. Directly replace a possibly faulty board with a new board verified as normal.

    Cable Replacement

    Cables that easily fail include TRXU RF cable, IIA port fiber/E1 line and rack fan connection line. Specific method:

    1. Connect RF cable of the TRXU, parts of which are possibly faulty, to DDL of another normal cell, and check status of the cell. TRXU and related parts are normal if the cell is still normal. Otherwise, replace them.

    2. Remove connected optical fiber and check it through self-loop if an optical interface of IIA is blocked. This optical interface is faulty if self-check is abnormal. Connect the fiber to another available optical interface of IIA and reconfigure the data. Replace the optical fiber or check peer equipment if the other optical interface is found normal in self-loop test.

    Caution

    Do not direct optical fiber interface to eyes, this may result in a serious injury.

    Do not look at IIA board optical interface directly, this may result in a serious injury.

    It is very difficult to remove fans on the rack. Check power cable first by connecting it to another slot or using other methods when finding that a fan is not working normally.

    Precautions

    Personnel Qualifications

    Maintenance personnel must receive pre-service training to learn necessary knowledge about the equipment and related network, and they must follow instructions given in related manuals of the ZXWR B09 to conduct maintenance.

    Maintenance personnel must have earnest attitudes and high competence.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    10 Confidential and Proprietary Information of ZTE CORPORATION

    Maintenance Management

    Make a complete set of equipment room maintenance regulations to standardize daily work of the maintenance personnel. Forbid non-maintenance management personnel to perform any maintenance operation.

    Make a detailed on-duty log to provide detailed records about system running, version status, data change, upgrade and problem handling for easy analysis and troubleshooting once any fault occurs.

    Make a work shift record to clearly define responsibilities.

    Do not play games or access the Internet through computer terminal. Do not install, run and copy any other software not related to the system at the terminal. Do not use the computer terminal for other purposes.

    Set NM passwords by level. Put them under strict management and change them periodically so that they are only accessible to maintenance personnel.

    Data Maintenance

    Do not reset the equipment, load or change any data unless absolutely necessary. Do not change background database at will.

    Backup the data before making any changes. Do not delete backup data after changing data until observation period (usually one week) expires and be sure that the equipment is running normally.

    Equipment Room Environment

    Maintain normal temperature/humidity in the equipment room. Keep the environment tidy and clean, free from dust and moisture. Keep rodents or insects out of the equipment room.

    Ensure that primary power of the system is stable and reliable, and check system grounding and lightning protection ground periodically. Check lightning protection system to make sure all facilities are in good condition, especially before storm seasons and after thunderstorms.

    The equipment room must have sufficient luminance compliant with relevant standards. Repair lamps damaged in time and make sure that light reaches all around the equipment room.

  • Chapter 1 Maintenance Overview

    Confidential and Proprietary Information of ZTE CORPORATION 11

    Tools and Instruments/Meters

    All common-use tools, instruments and meters must be available.

    Instruments and meters must be subject to periodic checking and calibration to ensure function availability and accuracy.

    Spare Materials and Parts

    Check spare materials and parts regularly to ensure sufficient stocks and to prevent them from mold.

    Store spare materials and parts and faulty ones separately. Mark them properly for easy identification.

    Technical Documents

    Store maintenance-related application software and technical documents by category at a specified location for easy access when necessary.

    Technical Support

    Handle faults immediately when they occur. Contact local office of ZTE Corporation for any faults you cannot solve.

    Display contact information of local office of ZTE at a conspicuous location in the equipment room. Make it known to all maintenance management personnel, and update it regularly.

  • Confidential and Proprietary Information of ZTE CORPORATION 13

    C h a p t e r 2

    Routine Maintenance

    This chapter introduces basic contents for routine maintenance of the ZXWR B09 and lists daily, weekly, monthly and semiannual routine maintenance items.

    Overview Routine maintenance refers to periodic preventive maintenance and check on the equipment so that the equipment can run in a stable state for long. Routine maintenance includes:

    1. Periodic maintenance check: Make routine check and test the BTS equipment running, required functions, important performance indices and hardware in compliance with prescribed operation steps and methods through various designated background operations or with necessary instruments and meters on regular and scheduled basis.

    2. Periodic check: Check hardware parts of BTS equipment and its attached equipment one by one. Adjust, correct or replace any defective part promptly to ensure equipment hardware is in good condition. Regularly maintain and clean components with high dust-proof requirements. Clean important components of other peripherals regularly for normal running.

    Caution

    Not all routine maintenance items described apply to all kinds of possible cases. It is acceptable to refer to them and work out routine maintenance items according to actual situation.

    RNC (Radio Network Controller), in WCDMA system, controls all radio parameters, so following maintenance items do not include network quality analysis and statistics.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    14 Confidential and Proprietary Information of ZTE CORPORATION

    Daily Routine Maintenance Items Table 1 shows daily routine maintenance items of the ZXWR B09.

    T AB L E 1 D AI L Y R O U T I N E M AI N T E N AN C E I T E M S

    Item Sub-item Contents Remar

    ks

    Alarms and notifications check

    Alarm message handling

    Check all alarms at the NM terminal, and handle them according to alarm level

    Notification message handling

    Analyze notification messages that frequently occur and it is acceptable to ignore common ones

    Troubleshooting

    Troubleshooting

    Handle common faults such as transmission fault and board fault

    Handle faults reflected by the users

    Analyze and handle network quality problem reflected by the user

    Weekly Routine Maintenance Items Table 2 shows weekly routine maintenance items of ZXWR B09.

    T AB L E 2 W E E K L Y RO U TI N E M AI N TE N AN C E I T E M S

    Item Sub-item Contents Remarks

    NM

    Data backup Backup configuration data for OMCB NMS

    Perform system backup at low-traffic

    Check and update operating system, anti-virus software and firewall software

    Install a patch for operation system of OMCB system

    Update virus library and check firewall record

    Update operating system immediately when there is a key update for it

    Disk capacity check

    Check whether disk space satisfies system running requirements

  • Chapter 2 Routine Maintenance

    Confidential and Proprietary Information of ZTE CORPORATION 15

    Monthly Routine Maintenance Items Table 3 shows monthly routine maintenance items of ZXWR B09.

    T AB L E 3 M O N T H L Y RO U TI N E M AI N T E N AN C E I TE M S

    Item Sub-item Contents Remarks

    Radio parameters

    Engineering parameters

    Check BTS location parameters

    Check antenna parameters

    Update parameters according to project situation. Save parameters for at least two years

    NM

    Hardware check

    Check whether host and peripherals are in good condition

    Check whether network communication is normal

    Software check

    Check whether operating system is running normally

    Checking whether NMS process is normal

    Check whether database system is running normally

    Data backup

    Complete backup log files

    Complete backup data files

    Backup the files every time before system upgrade, patching or network structure adjustment

    BTS equipment

    Check BTS equipment and its accessories

    Clean the equipment rack

    Clean the air filter

    Check the cable tree

    Check DDF, E1/fiber and all connectors

    Check BTS equipment

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    16 Confidential and Proprietary Information of ZTE CORPORATION

    Item Sub-item Contents Remarks

    indicators

    Equipment room environment

    Temperature and humidity

    Check temperature in the equipment room

    Check humidity in the equipment room

    Spare materials and parts

    Spare parts check

    Check spare parts for boards

    Check spare parts for racks

    Check other spare parts

    Semiannual Routine Maintenance Items Table 4 shows semiannual routine maintenance items of the ZXWR B09.

    T AB L E 4 SE M I AN N U AL RO U T I N E M AI N T E N AN C E I T E M S

    Item Sub-item Contents Remarks

    Lightning grounding

    Lightning grounding

    Check working ground of the equipment

    Check protection ground of the equipment room

    Check grounding trunk line of BTS

    Check lightning grounding of the building

    Test each type of grounding resistance

    Check all items before and after a natural disaster

    Antenna feeder system

    Iron tower

    Check tower light

    Check structure and foundation for any distortion or sinking

    Check uprightness and height of the tower

    Check all types of bolts

    Check anticorrosion and rustproof measures

    Check all items comprehensively when meeting gale force above 8, earthquake or other natural disaster

  • Chapter 2 Routine Maintenance

    Confidential and Proprietary Information of ZTE CORPORATION 17

    Item Sub-item Contents Remarks

    Pole

    Check installation of fixing parts

    Check stress on the pole, pull wire of pull wire tower and ground anchor

    Check anticorrosion and rustproof measures

    Check uprightness of the pole

    Antenna

    Check antenna installation parameters

    Check fixing status of the antenna

    Check pitch angle of the antenna

    Feeder

    Check installation of feeder and jumper

    Check feeder connectors

    Check waterproof and airproof measures for antenna feeder system

    Check grounding status for feeder

    Check water-dropping bend

    Other Recommended Maintenance Items Daily Routine Maintenance Items and Semiannual Routine Maintenance Items list maintenance items closely related to the ZXWR B09. There are still other maintenance items that affect the running of the network in daily operations. Refer to Table 5 for examples and recommended maintenance periods.

    T AB L E 5 EX AM P L E S O F O T H E R M AI N T E N AN C E I T E M S

    Item Sub-item Contents Recommended

    Period

    BTS equipment

    Standing wave ratio test

    Test standing wave ratio of each cell

    Semiannual

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    18 Confidential and Proprietary Information of ZTE CORPORATION

    Item Sub-item Contents Recommended

    Period

    Equipment room environment

    Cleanness

    Clean the floor, doors, windows, cabinets and other parts

    Monthly

    Lighting

    Check routine lighting and emergency lighting facilities

    Sockets

    Check whether AC sockets are complete and in good condition

    Safety

    Check to find out hidden safety troubles

    Check fire-control facilities

    Check protection measures for the equipment

    Devices in the equipment room

    Air conditioner

    Clean outdoor machine

    Clean the air filter

    Check all alarm messages

    Check installation of air conditioners

    Check drainages of air conditioners

    Measure input voltage and current

    Semiannual

    Environment monitoring system

    Check running status of each type of sensor

    Check the power display.

    Check the battery display.

    Clean chassis of monitoring system

    Monthly

    Low-voltage power distribution and switch power supply

    Check whether switch and connector are in good condition

    Check whether signal indicator and alarm are normal

    Clean power distribution device

    Check AC feeder

    Monthly

  • Chapter 2 Routine Maintenance

    Confidential and Proprietary Information of ZTE CORPORATION 19

    Item Sub-item Contents Recommended

    Period

    and connection parts

    Measure temperature rise of the fuser

    Battery

    Clean batteries

    Measure voltage of a single battery

    Measure end voltage of each battery and ambient temperature

    Check whether there is any liquid leakage

    Check whether contact of leading wire and terminal are well and whether there is erosion

    Check whether connection pieces between batteries are tight

    Quarterly

    Capacity discharging test

    Yearly

    Diesel generator

    Charge startup battery, and add distilled water when necessary

    Semimonthly

    Clean the equipment

    Check startup, cooling, lubricating and fuel systems

    Run the machine for 20 minutes, without any load

    Monthly

  • Confidential and Proprietary Information of ZTE CORPORATION 21

    C h a p t e r 3

    Notification and Handling

    This chapter introduces types of notification messages that may occur during running of the ZXWR B09, and gives possible causes of them.

    Notification Messages When any unrepeatable or transient abnormality occurs during the running of ZXWR B09, the system reports in the form of notification. Maintenance management personnel learn running status of each part of Node B from notification message.

    Board Notification

    SSCOP Error

    Item Contents

    Description SSCOP error

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause SSCOP receives error PDU

    ALCAP Link Error

    Item Contents

    Description ALCAP link error

    Alarm level Alarm notification

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    22 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Alarm type Error handling alarm

    Cause ALCAP receives invalid message or the status is error

    AAL5_MAC Error

    Item Contents

    Description AAL5_MAC error

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause Packet loss or error packet occurs on this link, or the switching network is error

    RS232 Serial Port Error

    Item Contents

    Description RS232 serial port error

    Alarm level Notification

    Alarm type Communication alarm

    Cause

    1. GPS RS232 serial port receiving frame CRC error;

    2. GPS RS232 serial port sending data error;

    3. Micro-Control Unit (MCU) RS232 serial port receiving frame CRC error;

    4. Micro-Control Unit (MCU) RS232 serial port sending data error.

    STM-1 B1 Error Code

    Item Contents

    Description STM-1 B1 error code alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause

    Quality of transmission line is deteriorated (optical power is too big or too small); there is strong electromagnetic interference near the optical interface; optical connector is not clean; ambient temperature where the equipment works is too high.

  • Chapter 3 Notification and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 23

    STM-1 B2 Error Code

    Item Contents

    Description STM-1 B2 error code alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause

    Quality of transmission line is deteriorated (optical power is too big or too small); there is strong electromagnetic interference near the optical interface; optical connector is not clean; ambient temperature where the equipment works is too high.

    STM-1 Remote B2 Error Code Indication

    Item Contents

    Description STM-1 remote B2 error code indication alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause This alarm is the reply alarm when peer end detects received B2 error codes.

    Examples of Other Maintenance Items STM-1 B3 Error Code

    Item Contents

    Description STM-1 B3 error code alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause

    Quality of transmission line is deteriorated (optical power is too big or too small); there is strong electromagnetic interference near the optical interface; optical connector is not clean; ambient temperature where the equipment works is too high.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    24 Confidential and Proprietary Information of ZTE CORPORATION

    STM-1 B3 Remote Error Code Indication

    Item Contents

    Description STM-1 B3 remote error code indication alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause This alarm is the reply alarm when peer end detects received B2 bit error.

    STM-1 Multiplex Section Remote Defect Indication (MSRDI)

    Item Contents

    Description STM-1 Multiplex Section Remote Defect Indication (MSRDI)

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause Peer end returns MSRDI alarm to this end when receiving LOS, LOF or MSAIS alarm.

    STM-1 Higher-order Path Defect Indication (HPRDI)

    Item Contents

    Description STM-1 Higher-order Path Defect Indication (HPRDI)

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause Remote end returns HPRDI alarm to this end when receiving HP-AIS, AU-LOP or path tracing byte mismatching message.

  • Chapter 3 Notification and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 25

    STM-1 Higher-order Path Lady Type Mismatching (HPPLM)

    Item Contents

    Description STM-1 Higher-order Path Lady Type Mismatching (HPPLM)

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause Load type (C2 byte) borne by higher-order path in STM-1 frame structure received by this end is not ATM. This alarm occurs along with other alarms.

    Loss of STM-1 Cell Delimitation (LCD)

    Item Contents

    Description Loss of Cell Delimitation (LCD) of STM-1

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause The clock is not synchronized or there is a bit error. Other STM-1 alarms occur at the same time usually.

    STM-1 Received Cell with CRC Error

    Item Contents

    Description STM-1 received cell with CRC error

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause The clock is not synchronized or there are error codes. Other STM-1 alarms occur at the same time generally.

    E1 Link HDB3 Coding Violation

    Item Contents

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    26 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Description E1 link HDB3 coding violates the rule

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause IIA board interface performance; E1 cable quality is poor; equipment shares the ground.

    E1 Link Slip

    Item Contents

    Description E1 link slip alarm

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause The E1 clock is out of synchronization.

    Too-Heavy ATM Traffic

    Item Contents

    Description ATM traffic is too heavy.

    Alarm level Alarm notification

    Alarm type Communication alarm

    Cause Actual traffic of ATM exceeds the preset bandwidth.

  • Confidential and Proprietary Information of ZTE CORPORATION 27

    C h a p t e r 4

    Alarm and Handling

    This chapter introduces types of alarm messages that may occur during running of the ZXWR B09, and gives severities (levels), possible causes and troubleshooting methods.

    Alarm Messages Any problem or fault that occurs during running of the ZXWR B09 is reported in form of an alarm message.

    Usually, alarm messages last some time and do not disappear until corresponding problems or faults disappear.

    Alarm messages fall into four levels, level 1: Critical, level 2: Major, level 3: Minor and level 4: Alarming.

    1. Critical alarm

    It is an alarm for board failure.

    For example: related resources of a board are blocked, functions of the system are fatally affected, and maintenance and management personnel need to replace the board or perform other troubleshooting procedures to clear the fault.

    2. Major alarm

    It is an alarm for a serious fault, and it will last for some time.

    Functions of the system are seriously affected, with signs of services being affected. For example, QoS of a type of equipment severely degrades, and maintenance and management personnel need to perform emergency repair to eliminate the fault.

    3. Minor alarm

    It is an alarm for a minor fault.

    Functions of the system are slightly affected, indicating existence of factors that do not affect normal services. It is necessary to take measures to prevent severe faults and to

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    28 Confidential and Proprietary Information of ZTE CORPORATION

    let maintenance and management personnel eliminate the fault.

    4. Alarming alarm

    It is an alarm that indicates existence of potential problems or problems that are about to affect normal services. It is necessary to take measures to prevent them from developing into faults that may severely affect normal services.

    Following sections details possible alarms in the system for users reference. Contact Customer Support Center of ZTE in time if failing to handle a generated alarm.

    CCS Alarms Note

    When handling with alarms, perform in the order of Handling until alarm vanish. For example, if there are 5 steps in Handling and alarms vanish when you go on with Step 3, Seps 4 and 5 are unnecessary.

    SSCOP Signaling Link Disconnected

    Item Contents

    Description SSCOP signaling link is disconnected.

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    1. Transmission layer parameters are not configured consistent for Node B, RNC and cascaded Node B;

    2. Node B transmission layer error;

    3. Communication cable error;

    4. Peer RNC or cascaded Node B fails.

    Handling

    1. Check whether transmission layer parameters are configured consistent for Node B, RNC and cascaded Node B. Modify configurations if not consistent;

    2. Reset IIA or CCS;

    3. Check whether communication cable gets faulty;

    4. Check whether peer RNC or cascaded Node B fails.

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 29

    Clock Reference Source Lost

    Item Contents

    Description Clock reference source lost

    Alarm level Alarming alarm

    Alarm type Equipment alarm

    Cause

    1. IIA1 clock reference source lost;

    2. IIA2 clock reference source lost;

    3. GPS clock lost;

    4. BITS clock lost,

    Handling

    If it is the line clock reference source lost, check whether the system configures the line clock reference source by mistake;

    If it is GPS 1pps reference source lost:

    1. Check whether there are alarms with GPS. Handle with them if there are any;

    2. Check whether connection between EMC and CCS is normal;

    3. Replace GPS.

    If it is 8 kHz clock reference source lost:

    1. Check whether connection between EMU and CCS is normal;

    2. Check the external clock.

    Clock Module Error

    Item Contents

    Description Clock module error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    1. 61.44 M clock alarm;

    2. 10 M clock alarm;

    3. FR alarm;

    4. FN alarm.

    Handling

    1. Check whether system clock signal are abnormal;

    2. Check whether there are clock signals input on boards;

    3. Check whether connection between boards and backplane is abnormal;

    4. Check whether board clock receiving module is abnormal.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    30 Confidential and Proprietary Information of ZTE CORPORATION

    Board Communication Link Disconnected

    Item Contents

    Description Board communication link is disconnected.

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause 1. Communication cables error;

    2. Board error.

    Handling

    1. Configuration board must be inserted in the slot. If it is the middle transfer board error, unplug the middle link disconnected board first;

    2. Unplug the link disconnected board;

    3. Replace the link disconnected board or middle transfer board.

    Active/Standby Synchronization Failure

    Item Contents

    Description Active/Standby synchronization failure

    Alarm level Minor alarm

    Alarm type Error handling alarm

    Cause

    1. Database active/standby synchronization failure;

    2. Operation software version synchronization failure;

    3. Backup software version synchronization failure.

    Handling

    1. Confirm whether there are active/standby link disconnected alarm;

    2. Confirm there are version error alarms on MS board and hardware error on backup board;

    3. Not intervene, waiting for the system to restore automatically;

    4. Reset the board if the system fails to restore automatically;

    5. Replace CCS backplane.

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 31

    Software Version Error

    Item Contents

    Description Software version error

    Alarm level Major alarm

    Alarm type Error handling alarm

    Cause There are correlated records of this software on the foreground or the file of this type software saved on the foreground is damaged.

    Handling Re-download faulty software version.

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether software version alarm exits;

    2. Reset the board;

    3. Replace the board.

    Board Parameter Synchronization Abnormal

    Item Contents

    Description Board parameter synchronization abnormal

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause

    1. Board is configured but not plugged;

    2. Board link is disconnected;

    3. Board software is abnormal.

    Handling

    1. Check whether there are board link alarms. If so, handle with the alarm and repeat the configuration process or restart the board;

    2. Check whether there are board application software monitoring alarms. If so, handle with the alarm and reset the board;

    3. Re-configure parameters on the background;

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    32 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    4. Re-start the board.

    Application Software Monitoring Alarm

    Item Contents

    Description Application software monitoring alarm

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause 1. Communication line error;

    2. Board error.

    Handling

    1. Check whether there are board link alarms;

    2. Reset;

    3. Replace the board with alarms.

    Database Save Failure

    Item Contents

    Description Database save failure

    Alarm level Minor alarm

    Alarm type Error handling alarm

    Cause 1. Harddisk error;

    2. Harddisk is full.

    Handling Replace the board.

    Reference Resource PRI Configuration Failure

    Item Contents

    Description Reference resource PRI configuration failure

    Alarm level Minor alarm

    Alarm type Equipment alarm

    Cause The system configures the reference source that is not supported.

    Handling Check whether the system has configured the reference source that is not supported. If so,

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 33

    Item Contents

    delete it and reset the board and the switching.

    SSCOP Delivery Buffer Overflow

    Item Contents

    Description SSCOP delivery buffer overflow

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause The message is abnormal.

    Handling Reset the CCS.

    Board Configuration Error Alarm

    Item Contents

    Description Board configuration error alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause

    1. The board on the left RBI slot is configured error;

    2. The board on the right RBI slot is configured error;

    3. The board on the BP slot is configured error.

    Handling Modify the background configurations.

    SNTP Time Alignment Failure Alarm

    Item Contents

    Description SNTP time alignment failure alarm

    Alarm level Alarming alarm

    Alarm type Communication alarm

    Cause 1. IP address of SNTP server is configured faulty;

    2. Link with SNTP server error.

    Handling

    1. Check whether the link with SNTP server is error;

    2. Check whether the IP address of SNTP server is configured faulty.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    34 Confidential and Proprietary Information of ZTE CORPORATION

    Clock Reference Source Deterioration

    Item Contents

    Description Clock reference source deterioration

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause The reference clock quality is too bad.

    Handling

    1. If current reference source is a line clock, inform RNC-related personnel of normal clock input;

    2. Replace the reference source.

    CPU Overload Alarm

    Item Contents

    Description Board configuration error alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Check whether there are alarms on the board and isolate the faulty board.

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

    Handling Replace the error board.

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 35

    RBI Alarms

    Clock Module Alarm

    Item Contents

    Description RBI clock module alarm

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    1. System clock signal is abnormal;

    2. Connection between board and backplane is abnormal;

    3. Board clock receiving module gets abnormal.

    Handling

    1. Check whether CCS has a clock alarm. Solve it first if such a clock alarm exists;

    2. Reset the RBI;

    3. Unplug and plug the RBI;

    4. Replace the RBI.

    Downlink LVDS Link Error

    Item Contents

    Description Downlink LVDS link error

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause

    1. LVDS transmitting module of upstream board is abnormal;

    2. LVDS link of corresponding backplane is abnormal;

    3. Interface between board and backplane is abnormal;

    4. LVDS receiving module gets abnormal.

    Handling

    1. Make sure corresponding board and backplane are in good contact;

    2. Reset the RBI;

    3. Reset upstream boards (BP and TRXU);

    4. Replace the RBI;

    5. Replace upstream boards.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    36 Confidential and Proprietary Information of ZTE CORPORATION

    Uplink LVDS Link Error

    Item Contents

    Description Uplink LVDS link error

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause

    1. LVDS transmitting module of corresponding TRXU is abnormal;

    2. LVDS link of corresponding backplane is abnormal;

    3. Interface between board and backplane is abnormal;

    4. LVDS receiving module gets abnormal.

    Handling

    1. Make sure corresponding board and backplane are in good contact;

    2. Reset the RBI;

    3. Reset corresponding TRXU;

    4. Replace the RBI;

    5. Replace corresponding TRXU.

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarm;

    2. Reset the board;

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or hardware error

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 37

    Item Contents

    Handling 1. Reset the board;

    2. Replace the board.

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the faulty board.

    Remote Clock Reference Alarm

    Item Contents

    Description Remote clock reference alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause

    1. System clock signals are abnormal;

    2. Connection between the board and the backplane is abnormal;

    3. Board clock receiving module is abnormal.

    Handling

    1. Check whether there are clock type alarms on the CCS. If so, handle with it first;

    2. Reset the RBI;

    3. Unplug the RBI;

    4. Replace RBI.

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    38 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Handling Replace the error board.

    Optical Module Not-in-position

    Item Contents

    Description Optical module is not in position.

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Corresponding optical module is not in position or abnormal.

    Handling Check whether the corresponding optical module is in position. If so, replace the corresponding optical module.

    Optical Module Receiving Failure

    Item Contents

    Description Optical module receiving failure

    Alarm level Minor alarm

    Alarm type Equipment alarm

    Cause

    1. The corresponding RF remote is abnormal;

    2. Fibers on corresponding optical interface are abnormal;

    3. Connection of optical interface that the board corresponds to is abnormal;

    4. Optical module that the board corresponds to is abnormal.

    Handling

    1. Confirm that the connection of the corresponding optical interface is well;

    2. Self-loop corresponding optical interface. If the alarm still exists, go on with Step 3. If the alarm disappears, it proves that it is the fiber or corresponding RF remote error. Check the fibers. If the fibers are normal, go on with Step 6;

    3. Reset the RBI;

    4. Replace RBI alarm optical module;

    5. Replace the RBI;

    6. If conditions permit, check whether corresponding RF remote is normal.

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 39

    IIA Alarms

    Loss Of Signal (LOS) of STM-1

    Item Contents

    Description Loss Of Signal (LOS) of STM-1

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    The fiber is not corrected or connected with inverse receiving and transmitting; the fiber is disconnected; local optical module is damaged; peer end does not send optical interface.

    Handling

    1. Connect the fiber with Node B if not already connected. Exchange receiving and transmitting fibers if the alarm still exists;

    2. Make self-loop for Node-B optical interface with a fiber. Replace optical module of IIA or replace IIA if the alarm still exists. Node B is OK if the alarm disappears. Go on with Step 3;

    3. Check status of RNC or optical transmission equipment connecting Node B. Loop back with fiber level by level to locate the fault.

    Loss Of Frame (LOF) of STM-1

    Item Contents

    Description Loss Of Frame (LOF) of STM-1

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause The clock is not synchronized.

    Handling

    1. Check CCS alarm status. Eliminate clock alarm first if it exists;

    2. Check whether clock status of RNC or transmission equipment is normal.

    Multiplex Section Alarm Indication of STM-1 (MSAIS)

    Item Contents

    Description Multiplex Section Alarm Indication of STM-1 (MSAIS)

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    40 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    MS-AIS alarm is sent to downstream equipment when LOS and LOF alarms occur to upstream equipment of Node B. It is also possible that NMS inserts an MSAIS alarm in transmission equipment.

    Handling Check alarm status of upstream equipment of Node B and eliminate the alarm.

    Loss Of Pointer (LOP) of STM-1 AU4

    Item Contents

    Description Loss Of Pointer (LOP) of STM-1 AU4

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause Unsynchronized clock of transmission equipment results in pointer adjustment.

    Handling

    1. Check whether CCS has a clock alarm;

    2. Check whether RNC or transmission equipment has a clock alarm.

    Loss Of Electrical Signal (LOS) of E1 Link

    Item Contents

    Description Loss Of electrical Signal (LOS) of E1 Link

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    E1 line is not connected or connected with inverse receiving and transmitting; E1 cable is disconnected; local E1 receiving module or peer E1 transmitting module is damaged.

    Handling

    1. Check whether E1 line of the alarm link is connected properly or connected with inverse receiving and transmitting;

    2. Make self-loop for the alarm link with E1 line. Node B is OK if the alarm disappears. Check whether peer equipment is normal;

    3. Insert IIA to another slot, and make self-loop with E1 line. E1 cable or E1 transfer board fails and must be

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 41

    Item Contents

    replaced if the alarm disappears and replace IIA if the alarm still exists.

    Loss Of Frame (LOF) Synchronization of E1 Link

    Item Contents

    Description Loss Of Frame (LOF) synchronization of E1 Link

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause The clock is out of synchronization.

    Handling

    1. Check whether there are Loss of electric Signal (LOS) alarm on IIA;

    2. Check whether there are lock alarms on the IIA;

    3. Check the alarm status of CCS;

    4. Reset the IIA;

    5. Check whether the clock status of RNC or transmission equipment is normal.

    Loss of Cell Delimitation (LCD) of E1 Link

    Item Contents

    Description Loss of Cell Delimitation (LCD) of E1 link

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    1. The clock is out of synchronization;

    2. The TC layer parameters for IMA connecting both parties are inconsistent.

    Handling

    1. Check the TC layer parameters for IMA connecting both parties. Modify them consistent if they are inconsistent;

    2. Check whether the RNC has a clock alarm.

    Loss of IMA Frame (LIF) of E1 Link

    Item Contents

    Description Loss of IMA Frame (LIF) of E1 link

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    42 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    1. The scrambling/descrambling parameters for IMA connecting dual-transmitting are set inconsistent;

    2. The clock is out of synchronization.

    Handling

    1. Check scrambling/descrambling parameters for IMA connecting dual-transmitting. Modify them consistent if they are inconsistent;

    2. Check whether the CCS has a clock alarm;

    3. Check whether RNC has a clock alarm.

    E1 IMA Group in Non-Working Status

    Item Contents

    Description The E1 IMA group is not in a working status.

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    This alarm indicates E1 link in IMA group gets faulty, and IMA group is not in a working state, unable to receive/send data. All above E1 alarms may result in this alarm.

    Handling

    1. Make self-loop for E1 link in IMA group at Node-B side. Node B fails if the alarm still exists. Solve the problem step by step by with the method for solving other E1 alarms. Go on with Step 2 if the alarm disappears

    2. Check whether both parties IMA settings (IMA version, scrambling/descrambling or not and frame length) are consistent. Modify them if they are inconsistent. Set IMA clock mode of Node B as ITC if doubting the clock fails. The clock is error and check clock boards of the peer end and local end if the alarm disappears. Make loop-back level by level to locate the section where the problem occurs if doubting E1 connection line fails.

    PVC Error

    Item Contents

    Description PVC error

    Alarm level Major alarm

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 43

    Item Contents

    Alarm type Communication alarm

    Cause ATM link error

    Handling

    Perform the link self-loop. If the alarm disappears, it indicates that Node B is normal. Check the opposite equipment. If the alarm still exists, replace the board.

    Transmission Clock Abnormal

    Item Contents

    Description Transmission clock abnormal

    Alarm level Minor alarm

    Alarm type Communication alarm

    Cause The board is not inserted tight. CCS clock unit error. Board error. Backplane error, etc.

    Handling

    1. Check whether there are clock type alarm on CCS;

    2. Unplug and plug the IIA;

    3. Replace the IIA.

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarm;

    2. Reset the board;

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    44 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Cause Configuration parameter error or hardware error

    Handling 1. Reset the board;

    2. Replace the board.

    Configuring IMA Group Failure

    Item Contents

    Description Configuring IMA group failure

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause Iub port already exists or parameter error

    Handling

    1. Confirm that parameter configurations are correct;

    2. Delete this IMA group and configure again;

    3. Reset the board;

    4. Replace the board.

    Configuring STM-1 Port Failure

    Item Contents

    Description Configuring STM-1 port failure

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause Iub port already exists or parameter error

    Handling

    1. Confirm that parameter configurations are correct;

    2. Delete this IMA group and configure again;

    3. Reset the board;

    4. Replace the board.

    Configuring TC Port Failure

    Item Contents

    Description Configuring TC port failure

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause Parameter error

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 45

    Item Contents

    Handling

    1. Confirm that parameter configurations are correct;

    2. Delete this TC group and configure again;

    3. Reset the board;

    4. Replace the board.

    Configuring PVC Failure

    Item Contents

    Description Configuring PVC failure

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause 1. Parameter error;

    2. Hardware error.

    Handling

    1. Confirm that parameter configurations are correct;

    2. Delete this PVC and configure again;

    3. Reset the board;

    4. Replace the board.

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the faulty board.

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware error

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    46 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Handling Replace the error board

    Optical Module Not-in-position

    Item Contents

    Description Optical module is not in position.

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Corresponding optical module is not in position or abnormal.

    Handling Check whether the corresponding optical module is in position. If so, replace the corresponding optical module.

    TAC Alarms

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarm;

    2. Reset the board;

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or hardware error

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 47

    Item Contents

    Handling 1. Reset the board;

    2. Replace the board.

    Board Hardware Local Channel Error

    Item Contents

    Description Board hardware local channel error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Error of tower amplifier that TA corresponds to

    Handling Replace the tower amplifier

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware error

    Handling Replace the error board.

    EMU Alarms

    Ambient Temperature Abnormal

    Item Contents

    Description Ambient temperature is abnormal.

    Alarm level Major alarm

    Alarm type Ambient alarm

    Cause

    1. The temperature is too high or too low (out of the temperature range that the system configures);

    2. EMU board error

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    48 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Handling

    1. Check whether the threshold of configuration parameters is too high or too low;

    2. Check whether the ambient temperature is too high (low) with the thermometer;

    3. Reset the EMU;

    4. Replace the temperature sensor;

    5. Replace the EMU.

    Whole Equipment Temperature Rise Alarm

    Item Contents

    Description Whole equipment temperature rise alarm

    Alarm level Major alarm

    Alarm type Ambient alarm

    Cause

    Temperature difference at EMU intake and outtake detected by EMU is over 15 C. Possible causes

    are:

    1. Dust-proof net is blocked;

    2. Fan error;

    3. Temperature sensor error;

    4. EMU board error.

    Handling

    1. Check whether there are alarms on fans;

    2. Check whether the dust-proof net on racks are blocked;

    3. Replace the two temperature sensors of set-top fans;

    4. Reset the EMU;

    5. Replace the EMU.

    Clock Reference Source Loss

    Item Contents

    Description Clock reference source loss

    Alarm level Alarming alarm

    Alarm type Equipment alarm

    Cause 1. EMU 2 MHz loss;

    2. EMU 2 Mbps loss.

    Handling 1. Check whether the clock reference source is configured;

    2. Check whether there are external BITS. If so,

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 49

    Item Contents

    check whether the BITS has clock output signals and whether it is normal;

    3. Check whether the connection between BITS and EMU is correct.

    Rack Power Abnormal

    Item Contents

    Description Rack power abnormal

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause

    1. 48 V over-voltage (over 57 V 1 V);

    2. 48 V under-voltage (below 40 V 1 V);

    3. EMU board error;

    4. Lightening arrester error.

    Handling

    1. If it is the voltage alarm, use the multimeter to detect the rack power voltage. If the measured value is over or under voltage, it indicates that something is wrong with the voltage of 48 V power and it needs solution;

    2. If it is the lightening arrester alarm, replace it to detect the alarm status. If the alarm disappears, it indicates that the lightening arrester is damaged and it is necessary to replace one;

    3. Reset the EMU;

    4. Replace the EMU.

    Board Communication Link Disconnected

    Item Contents

    Description Board communication link disconnected

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause 1. Communication cable error;

    2. Board error.

    Handling

    1. The configured board should be inserted in the slot. If it is the middle transit board error, unplug it first;

    2. Unplug the link disconnected board;

    3. Replace the link disconnected board or middle transit board.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    50 Confidential and Proprietary Information of ZTE CORPORATION

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarms;

    2. Reset the board;

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or hardware error

    Handling 1. Reset the board;

    2. Replace the board.

    Fan Alarm

    Item Contents

    Description Fan alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause

    1. Cable error;

    2. Fan error;

    3. EMU error.

    Handling

    1. Check whether there are alarms on the whole layer of fans. If so, check cables of EMU and fans;

    2. Replace faulty fans;

    3. Reset the EMU;

    4. Replace the EMU.

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 51

    Temperature Sensor Not-in-position

    Item Contents

    Description Temperature sensor is not in position.

    Alarm level Minor alarm

    Alarm type Equipment alarm

    Cause

    1. Cables between EMU and fan layer is error;

    2. Temperature sensor connection is error;

    3. FCC or FCD error;

    4. EMU error.

    Handling

    1. Check whether connection between the fan board in the layer that faulty temperature sensor locates and EMU is faulty;

    2. Open corresponding fan layer to check whether the temperature sensor is connected to FC correctly;

    3. Replace the FC board that the faulty temperature sensor corresponds to;

    4. Reset EMU;

    5. Replace EMU.

    Father Node External Equipment Error

    Item Contents

    Description Father node external equipment error

    Alarm level Alarming alarm

    Alarm type Equipment alarm

    Cause

    1. External equipment error;

    2. Father node connection error;

    3. EMU error.

    Handling

    1. Check whether there are faults with external equipment;

    2. Check whether connections between external equipment and father node is normal;

    3. Replace the EMU.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    52 Confidential and Proprietary Information of ZTE CORPORATION

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the error board.

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

    Handling Replace the error board.

    TRXU Alarms

    Clock Module Error

    Item Contents

    Description Clock module error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    1. 61.44 M clock alarm;

    2. 10 M clock alarm;

    3. FR alarm;

    4. FN alarm.

    Handling

    1. Check whether system clock signals are normal;

    2. Check whether there are clock signal input on boards;

    3. Check whether the connection between the

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 53

    Item Contents

    board and the back plane is normal;

    4. Check whether the board time receiving module is normal.

    Downlink LVDS Link Error

    Item Contents

    Description Downlink LVDS link error

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause

    1. Upstream board LVDS transmitting module is abnormal;

    2. LVDS link of corresponding backplane is abnormal;

    3. Interface between board and backplane is abnormal;

    4. Board LVDS receiving module is abnormal.

    Handling

    1. Make sure alarm board and backplane are in good contact;

    2. Reset the alarm board;

    3. Reset the upstream boards (RBI);

    4. Replace the alarm board;

    5. Replace the upstream boards.

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarm;

    2. Reset the board;

    3. Replace the board.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    54 Confidential and Proprietary Information of ZTE CORPORATION

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or hardware error

    Handling 1. Reset the board;

    2. Replace the board.

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the faulty board.

    Board Hardware Local Channel Error

    Item Contents

    Description Board hardware local channel error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Transmitting or receiving channel error

    Handling Replace the tower amplifier

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 55

    Item Contents

    Alarm type Equipment alarm

    Cause Equipment hardware error

    Handling Replace the error board

    BP Alarms

    Clock Module Error

    Item Contents

    Description Clock module error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    1. 61.44 M clock alarm;

    2. 10 M clock alarm;

    3. FR alarm;

    4. FN alarm.

    Handling

    1. Check whether system clock signals are normal;

    2. Check whether there are clock signal input on the board;

    3. Check whether the connection between the board and the backplane is normal;

    4. Check whether the board clock receiving module is normal.

    Uplink LVDS Link Error

    Item Contents

    Description Uplink LVDS link error

    Alarm level Major alarm

    Alarm type Communication alarm

    Cause

    1. LVDS link of corresponding backplane is abnormal;

    2. Interface between the board and the backplane is abnormal;

    3. Board LVDS receiving module is abnormal.

    Handling 1. Determine whether the board and the backplane is well connected;

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    56 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    2. Reset the RBI;

    3. Reset the corresponding TRXU;

    4. Replace the RBI;

    5. Replace the corresponding TRXU.

    Uplink Path Operation Abnormal

    Item Contents

    Description Uplink path operation is abnormal.

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause 1. Internal communication error;

    2. Hardware error.

    Handling 1. Reset or unplug the board;

    2. Replace the BP.

    Downlink Path Operation Abnormal

    Item Contents

    Description Downlink path operation is abnormal.

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause BP high-layer software and DSP communication error

    Handling 1. Reset or unplug the board;

    2. Replace the BP.

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version alarm;

    2. Reset the board;

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 57

    Item Contents

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or hardware error

    Handling 1. Reset the board;

    2. Replace the board.

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the faulty board.

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

    Handling Replace the error board.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    58 Confidential and Proprietary Information of ZTE CORPORATION

    Signal Receiving Path Quality Abnormal Alarm

    Item Contents

    Description Signal receiving path quality abnormal alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Receiving path error

    Handling Check whether the RF cable interface (including antenna interface) of corresponding path is loose.

    RDM Alarms

    Clock Module Error

    Item Contents

    Description Clock module error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    1. 61.44 M clock alarm;

    2. 10 M clock alarm;

    3. FR alarm;

    4. FN alarm.

    Handling

    1. Check whether system clock signals are normal;

    2. Check whether there are clock signal input on the board;

    3. Check whether the connection between the board and the backplane is normal;

    4. Check whether the board clock receiving module is normal.

    Antenna VSWR Exceeding 3.0

    Item Contents

    Description The antenna VSWR (Voltage Standing Wave Ratio) exceeds 3.0.

    Alarm level Critical alarm

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 59

    Item Contents

    Alarm type Equipment alarm

    Cause The backplane and RF cable are not in good contact.

    Handling

    1. Unplug and plug RDM board to make sure it is in good contact with the backplane;

    2. Check to make sure antenna at DDL antenna interface is screwed tight;

    3. Check to confirm if water enters the antenna;

    4. Reset RDM.

    Antenna VSWR Exceeding 1.8

    Item Contents

    Description The antenna VSWR exceeds 1.8.

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause The backplane and RF cable are not in good contact.

    Handling

    1. Unplug and plug RDM to make sure it is in good contact with the backplane;

    2. Check to make sure the antenna at the DDL antenna interface is screwed tight;

    3. Check to confirm if water enters the antenna;

    4. Reset RDM.

    Calibration Interface Over-power Alarm

    Item Contents

    Description Calibration interface over-power alarm

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Power at calibration interface is over 30 dBm.

    Handling

    1. Check whether there are RF cables connected with DDL antenna interface at RDM calibration interface. If so, go on with Step 2. If not, go on with Step 3;

    2. Check whether there are local cells in TRXU connecting DDL RF cables. If so, block this local cell;

    3. Reset the RDM.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    60 Confidential and Proprietary Information of ZTE CORPORATION

    Software Operation Failure

    Item Contents

    Description Software operation failure

    Alarm level Critical alarm

    Alarm type Error handling alarm

    Cause Software version error or board error

    Handling

    1. Check whether there are software version error;

    2. Reset the board;

    3. Replace the board.

    Board Configuration Parameter Error

    Item Contents

    Description Board configuration parameter error

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Configuration parameter error or board error

    Handling 1. Reset the board;

    2. Replace the board.

    CPU Overload Alarm

    Item Contents

    Description CPU overload alarm

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause High-layer software operation abnormal or board error, which results in frequent alarm reports.

    Handling Observe whether there are alarms on the board and isolate the faulty board.

    Board Hardware Error

    Item Contents

    Description Board hardware error

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 61

    Item Contents

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

    Handling Replace the error board

    LPA30 Alarms

    Board Hardware Error

    Item Contents

    Description Board hardware error

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Equipment hardware is abnormal.

    Handling Replace the error board.

    Link Disconnected between LPA30 and EMC

    Item Contents

    Description Link between LPA30 and EMC is disconnected.

    Alarm level Critical alarm

    Alarm type Communication alarm

    Cause 1. Communication cable is error;

    2. LPA30 fails.

    Handling 1. Unplug and plug the LPA30;

    2. Replace the LPA30.

    Over-power Alarm

    Item Contents

    Description LPA30 over-power alarm

    Alarm level Critical alarm

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    62 Confidential and Proprietary Information of ZTE CORPORATION

    Item Contents

    Alarm type Equipment alarm

    Cause Possibly signal power of power amplifier LPA30 input port, exceeds maximum output power 2dB.

    Handling

    1. Enable protected power amplifier;

    2. Reset or restart the alarm power amplifier LPA30;

    3. Replace the TRXU;

    4. Replace the LPA30.

    Over-VSWR Alarm: VSWR2.8

    Item Contents

    Description LPA30 over-VSWR alarm, VSWR2.8

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause

    Matching of power amplifier LPA30 port may fail (for example, cable output to the duplexer is not in good contact, or duplexer output port is not in good contact with the feeder).

    Handling

    1. Check whether power amplifier cable output to the duplexer is in good contact, and whether cable connector is screwed tightly;

    2. Check whether connectors between duplexer output port and feeder and between antenna and feeder are screwed tightly;

    3. Reset the LPA30;

    4. Replace the LPA30.

    Over-Temperature Alarm

    Item Contents

    Description LPA30 over-temperature alarm

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Power amplifier layer may fail in heat sinking. For example, fans on the power amplifier layer work abnormally.

    Handling

    1. Confirm if EMU generates a heat-sinking fan alarm on power amplifier layer;

    2. Enable protected LPA30 board and make a recovery attempt;

    3. Reset the LPA30;

  • Chapter 4 Alarm and Handling

    Confidential and Proprietary Information of ZTE CORPORATION 63

    Item Contents

    4. Replace the LPA30.

    Over-Current Alarm

    Item Contents

    Description LPA30 over-current alarm

    Alarm level Critical alarm

    Alarm type Equipment alarm

    Cause Possibly power amplifier LPA30 fails.

    Handling

    1. Enable protected LPA30 board and make a recovery attempt;

    2. Reset the LPA30;

    3. Replace the LPA30.

    LPA30 VSWR Alarm, 2.8>VSWR1.8

    Item Contents

    Description LPA30 VSWR alarm, 2.8>VSWR1.8

    Alarm level Major alarm

    Alarm type Equipment alarm

    Cause Matching of power amplifier LPA30 port may fail.

    Handling

    1. Check to make sure that power amplifier cable output to duplexer is in good contact and cable connector is screwed tightly;

    2. Check to make sure that connectors between duplexer output port and feeder and between antenna and feeder are screwed tightly.

  • Confidential and Proprietary Information of ZTE CORPORATION 65

    C h a p t e r 5

    Troubleshooting Examples

    This chapter introduces some common problems during routine operation and maintenance of the ZXWR B09, and presents symptoms, possible causes and solutions.

    Overview Table 6 shows possible problems during routine maintenance of the ZXWR B09.

    T AB L E 6 CO M M O N P R O B L E M S I N RO U T I N E M AI N T E N AN C E

    Classification Problem Remarks

    System monitoring

    CPU utilization too high

    See High CPU Utilization

    Decreased cell radius of BTS coverage

    See Decreased Radius of BTS Coverage

    User complaint

    Difficult call connection

    See Difficult Call Connection

    Poor call quality See Poor Call Quality

    Slow to access Internet

    See Slow to Access Internet

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    66 Confidential and Proprietary Information of ZTE CORPORATION

    System Monitoring

    High CPU Utilization

    Symptoms and Effects

    Alarm man-machine interface of operation and maintenance console has a CPU utilization alarm reported, or CPU utilization exceeds normal value for a long time when monitoring CPU utilization at performance management man-machine interface.

    High CPU utilization is of great concern. Processing capability of the system decreases if CPU of CCS is at a high utilization for a long time. It results in sharp rise of call loss and may cause memory exhaustion or system breakdown.

    Causes

    Rise of CPU utilization of a board (particularly CCS board) may result from:

    1. The system is busy currently, for example, high traffic.

    2. Too many measurement tasks are set, and there are more measurement report messages.

    3. The system has a local emergency fault, causing a large number of alarm messages reported

    Handling

    Analyze the cause and take appropriate measures in case of high CPU utilization ratio for a long time.

    1. Locate the fault and isolate it by blocking failed board and parts or using other methods if there is a large amount of burst alarm reports.

    2. Adjust measurement strategy properly if there are too many measurement message reported, for example, cancel some less important measurement tasks or change the period when performing measurement tasks.

  • Chapter 5 Troubleshooting Examples

    Confidential and Proprietary Information of ZTE CORPORATION 67

    Decreased Radius of BTS Coverage

    Symptoms and Effects

    Conversation quality at the edge of cell decreases, and measurement with instruments shows that coverage radius of BTS signals decreases.

    Causes

    1. Some radio parameters are set improperly, particularly pilot channel transmitting power and forward transmitting power, which affects actual coverage of BTS.

    2. Surrounding landform and geographical feature changes, for example, urban construction, also affect actual coverage.

    3. Interference in space electromagnetic environment causes pilot pollution.

    4. Antenna feeder system gets faulty.

    Handling

    Conduct an on-site survey and detailed spectrum test near the site, and configure radio parameters again based on ambient characteristics and test result. It is better to let professional network optimization personnel perform this task.

    User Complaints

    Difficult Call Connection

    Symptoms and Effects

    Users complain that call completion rate (successfully connected to called party) decreases significantly and calls cannot be connected at all in extreme cases.

  • WR_TS02_E1_0 ZXWR Node B Maintenance

    68 Confidential and Proprietary Information of ZTE CORPORATION

    Causes

    Call completion rate is a basic index to evaluate overall performance of the system. A great variety of factors may affect it, inclu