METRICS

For each Renewable Option, the following factors were compiled and analyzed:

The factors highlighted in grey are evaluated in the following report.

METHODOLOGY

Capacity ReliabilityTechnology

RiskLegal/

RegulatoryAvailable Incentives

Carbon Footprint

Environmental Impact

Payback Period

Marginal CostEase of

Implementation

All sources listed on accompanying spreadsheet

RENEWABLE ENERGY ENERGY SOLUTIONSSOLUTIONS

Solution Overview

Parabolic Trough (CSP)

Trough technology is a type of solar thermal energy collector and is constructed as a long parabolic mirror. Sunlight is reflected by the mirror and concentrated on a central tube. It uses one-axis (usually North to South) tracking and achieves a maximum temperature of about 400°C. This relatively low operating temperature makes it very difficult to provide the amount of heat storage (in a cost-effective manner) that is required for around-the-clock availability.

Power Tower (CSP)

Tower receiver technology uses two-axis tracking and achieves a maximum temperature of about 650°C. The higher operating temperature of tower technology reduces susceptibility of these systems to efficiency losses, especially when dry cooling is used.

Dish Sterling/Dish Engine (CSP)

Dish Engine systems convert solar thermal energy into mechanical energy and then to electrical energyin much the same way that conventional power plants convert thermal energy from combustion of a fossil fuel to electricity. They use a mirror array to reflect and concentrate incoming sunlight onto a receiver. Dish Engine systems have the inherent hybrid capability to operate on either solar energy or a fossil fuel, or both, making them an attractive option.

Linear Fresnel Reflector (CSP)

Linear Fresnel reflector technology uses one-axis tracking and achieves a maximum temperature of about 400°C. The reduced efficiency (15% to 25%) compared to troughs is expected to be offset by substantially lower capital costs.

Concentrating solar power (CSP) technologies use mirrors to reflect and concentrate sunlight onto receivers that collect the solar energy and convert it to heat. This thermal energy can then be used to produce electricity via a steam turbine or heat engine driving a generator. The following four technologies are forms of CSP:

Solar PV

Large Scale Solar PV Installations generate electrical power by converting solar radiation into direct current electricity using semiconductor panels. Rapid advancements in PV technology are making it an increasingly cost-effective option for utilities who require it in their energy portfolio.

Big Wind

Large wind farms, thanks to increased investment and policy, are very prevalent across the US. With a very low marginal cost ($0.01-$0.02/kWh) and several mechanisms in place to expedite their development in California, utility use of wind power continues to grow. Storage issues, however, limit the availability of energy needed to match peak loads, making new transmission infrastructure a critical factor in their development.

Biomass/Biogas

Biomass includes agricultural residues, forest resources, perennial grasses, woody energy, crops, wastes (municipal solid waste, urban wood waste, and food waste), and algae. It is unique among renewable energy resources in that it can be converted to carbon-based fuels and chemicals, in addition to power.

Geothermal

Utility-scale geothermal power production employs three main technologies. These are known as dry steam, flash steam and binary cycle systems. The technology employed depends on the temperature and pressure of the geothermal reservoir. Unlike solar, wind, and hydro-based renewable power, geothermal power plant operation is independent of fluctuations in daily and seasonal weather.

RENEWABLE ENERGY SOLUTIONS

CAPACITYTo measure the productivity of a renewable energy option, we use its Capacity Factor (CF), which is the amount of energy a power station generates over time (usually a year) compared to what it could have produced if it had been running at full power for the whole period. Capacity Factor is important not only because it reflects the performance of a power station, but also because a higher capacity factor represents a more stable power grid.

0.56

0.25 0.25

0.54

0.2

0.4

0.7

0.85

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Pa

rabo

lic Tr

ough

Po

wer To

wer

Dish

Ste

rling

(Dish

Eng

ine)

Lin

ear F

resn

el R

eflec

tor

Solar P

V

Big

Win

d

Biom

ass/Bi

ogas

Geoth

erm

al

Renewable Energy Options

Cap

acity

Fac

tor

CAPACITY INSIGHTS

Geothermal Energy’s high capacity factor is due to the nature of its source, the Earth’s heat, which is independent of daily and seasonal weather fluctuations, allowing it to run at full power most of the time. It’s ability to match peak loads, makes it a promising option

to replace dirty coal in the energy mix.

Similarly, with a steady supply, Biomass/gas plants can run at full power around the clock.

Of the four CSP based Solutions, Parabolic Reflector Technologies - Linear Fresnel and Parabolic Trough have significantly greater productivity and grid stability than the other two options. It should be noted, however, that Power Tower technologies, have a projected Capacity Factor of .73. Although development is less advanced than Parabolic Reflector based systems, they offer higher efficiency and better energy storage capability, which is required for around-the-clock dispatchability (NREL).

Renewable Energy Option

Capacity Factor

Geothermal .85

Biomass/Biogas .70

Parabolic Reflector Technologies:• Parabolic Trough • Linear Fresnel

.56 .54

Nuclear .95 - .98

Coal .65 - .75

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Pa

rabo

lic Tr

ough

Po

wer To

wer

Dish

Ste

rling

(Dish

Eng

ine)

Lin

ear F

resn

el R

eflec

tor

Solar P

V

Big

Win

d

Biom

ass/Bi

ogas

Geoth

erm

al

An Availability Factor (AF) is used to determine how reliable or constant an energy source is, especially during peak loads. Note, this is different from capacity factor which measures what percentage of the time the plant is able to run at full capacity. When looking at the AF it is important not only to compare across renewable sources but also to conventional fossil fuel based sources.

RELIABILITY

Renewable Energy Options

Ava

ilab

ility

Fa

cto

r 1

(L

ow

) -

5 (

Hig

h)

RELIABILITY INSIGHTS

Although Solar is an intermittent resource, concentrated solar energy can be stored at high temperatures using molten salts. Salts are an effective storage medium because they are low-cost, have a high specific heat capacity and can deliver heat at temperatures compatible with conventional power systems.

Renewable Energy Option Availability Factor

Geothermal .80

Concentrated Solar Technologies

.70

WindBiomass/Biogas

.30

.80

Geothermal is considered the most reliable source due to its ability to generate a steady stream of energy 24/7.

Wind and Biomass/Biogas are less reliable since their energy source is more variable.

Coal .65 - .90

Nuclear .70 - .90 (depending on how new the plant is)

INSIGHTS CONT…

BioMass/Gas Source Breakdown

Wood

Municiple Waste

Agricultural Waste

Land Fill Gas

Wind, also an intermittent source, cannot guarantee constant availability. And without storage, must be used as soon as it is produced, or immediately transported to where it can be used, through transmission lines. Improved reliability is possible with a widely geographically dispersed set of wind farms, raising its availability factor to .85.

Wood comprises the majority of the energy source. Therefore, logging regulations and transportation costs vary greatly depending on the location of the plant.

Image: http://www.dasgelbeforum.de.org/

0

1

2

3

4

5

Pa

rabo

lic Tr

ough

Po

wer To

wer

Dish

Ste

rling

(Dish

Eng

ine)

Lin

ear F

resn

el R

eflec

tor

Solar P

V

Big

Win

d

Biom

ass/Bi

ogas

Geoth

erm

al

TECHNOLOGY RISK RISKTechnology Risk is the degree of uncertainty associated with technology performing according to its planned or desired functionality. It is important when considering renewable energy options because performance in lab or pilot studies can vary greatly from installed & operational performance.

Renewable Energy Options

Tec

hnol

ogy

Ris

k R

atin

gs 1

(H

igh

Ris

k) -

5 (

Low

Ris

k)

TECHNOLOGY RISK INSIGHTS RISK INSIGHTSRenewable Energy Option Rating

Parabolic TroughSolar PVWind Biomass/Biogas

5 (Low)

Linear FresnelGeothermal

43

(Moderate)

Power TowerDish Sterling (Dish Engine)

2 (High)

• Trough technology is further advanced than tower, fresnel and dish technology, with 354 MW of commercial generation in operation in US. It is fully mature and there is low technical and financial risk in developing near-term plants. • Solar PV, Wind & Biomass/gas are all well established technologies with proven operational performance. • Linear Fresnel, while the oldest CSP technology, suffers from a lack of reference plants already built, as well as up and running.• Geothermal energy provided 16,010 GWh of electricity in 2005. However, larger scale use is limited unless permeability can be increased. The DOE has determined that the most critical near-term goal is the successful demonstration of Enhanced Geothermal Systems (EGS) and has identified 2015 as the key decision point for determining if it is technically feasible. • Tower technology has been successfully demonstrated with a conceptual and pilot plants (Solar One and Solar Two) but has not been proven in a large commercial application.• Dish Engine systems face high technology development risk. The DOE is currently working with companies to design, develop, install, and test pre-production prototype 25-kilowatt systems.

ENVIRONMENTAL RISKEnvironmental Risks associated with utility-scale Renewable Energy Installations can be very high and vary greatly on a site-by-site basis. Mitigating these risks can delay projects for years and cost millions in legal fees. Additionally, over the life of a plant the laws and regulations governing the environmental impacts are likely to change.

Renewable Energy Options

Env

ironm

enta

l Ris

k R

atin

gs 1

(H

igh

Ris

k) -

5 (

Low

Ris

k)

0

1

2

3

4

5

Pa

rabo

lic Tr

ough

Po

wer To

wer

Dish

Ste

rling

(Dish

Eng

ine)

Lin

ear F

resn

el R

eflec

tor

Solar P

V

Big

Win

d

Biom

ass

Biog

as

Geoth

erm

al

ENVIRONMENTAL RISK INSIGHTSRenewable Energy Option Rating

WindLinear Fresnel ReflectorSolar PVBiogasGeothermal

5 (Low)

Power TowerParabolic TroughDish Engine

3 (Moderate)

Biomass 2 (High)

• Wind carries low environmental risk because land is minimally effected and can still be used for agriculture/livestock. Additionally, it is well established and environmental risk assessments are easily carried out. • Linear Fresnel installations use less than 4 acres/MW, making the land requirement less than trough plants because more surface area can be covered with mirrors.• Solar PV installations use 4 acres/MW, and have minor panel disposal issues. • Biogas generation typically improves air quality, since methane from landfills is used as an energy source instead of being released into the atmosphere. • Geothermal energy has low environmental risk and impact. When used with a closed-loop binary power plant, geothermal systems emit zero greenhouse gas emissions and have a near zero environmental risk or impact. Typically parabolic trough power plants use about 8-10 acres/MW, Tower and Dish Engine use 10-15 acres/MW. Installations are usually are in remote desert areas, however unique plants and animals have to be protected costing time and money. Biomass power raises the most environmental issues.. Combustion of biomass and biomass-derived fuels produces air pollution; beyond this, there are concerns about the impacts of using land to grow energy crops that could be used for food.

MARGINAL COST ESTIMATESOne of the most important factors in evaluating how competitive renewable energy options are with traditional fossil fuels is the Levelized Cost of Energy (LCOE), or constant price per unit of energy that causes the utility company’s investment to break even. The LCOE equation evaluates the life-cycle energy cost and production of a power plant, allowing alternative renewable energy options to be compared.

Renewable Energy Options

Ma

rgin

al C

ost

($

/kW

h)

.06 - .10

.04 - .06 .06.07

.30 - .40

.01 - .02

.05 - .08 .08 - .10

MARGINAL COST INSIGHTS

Renewable Energy Option Levelized Energy Cost ($/kWh)

Wind Power Tower

$0.01 - $0.02$0.04 - $0.06

GeothermalBiomass/Biogas Dish Sterling/Dish EngineLinear FresnelParabolic Trough

$0.08 - 0.10$0.05 - $0.08

$0.06$0.07

$0.06 - $0.10

Solar PV $0.30 - $0.40

• Even with wind generation’s high upfront costs, low maintenance and low operational costs drive the LCOE down.• With advances in technology, Power Towers are expected to be the most economical solar energy technology with estimates of less than 4 cents/kWh.

•The other 3 CSP technologies range between $0.06 - $0.10/kWh. Prices are expected to drop as more plants become operational and efficiencies are gained from new technologies. • Biomass prices depend on the price of its source, which can vary widely at times. Utility-Scale Solar PV installation have the highest LCOE, which is greatly influenced by the plants capacity factor. By raising the capacity factor, the LCOE can decrease substantially, even up to four times lower.

AVAILABLE INCENTIVESFederal/State policy and tax incentives greatly influence utility investment in renewables and can help them offset high initial costs. The availability and degree of incentives for renewable energy options varies across industries and states.

0

1

2

3

4

5

Pa

rabo

lic Tr

ough

Po

wer To

wer

Dish

Ste

rling

(Dish

Eng

ine)

Lin

ear F

resn

el R

eflec

tor

Solar P

V

Big

Win

d

Biom

ass/Bi

ogas

Geoth

erm

al

Renewable Energy Options

Ince

ntiv

es

Ra

ting

1 (

Lo

w)

- 5

(H

igh

)

INCENTIVES INSIGHTSRenewable Energy Option Rating

WindSolar PV

5 (High)

Power TowerParabolic TroughDish EngineLinear Fresnel ReflectorBiomass/Biogas

3 (Moderate)

Geothermal 2 (Low)

Wind and Solar PV receive a high degree of tax and policy incentives. Large Federal tax incentives and new state policies that expedite permitting, environmental reviews and approval processes for new Wind Farms and Solar PV installations have enabled both industries to flourish. c• Concentrated Solar Technology is also receiving a relatively high degree of support. The same federal tax incentives are available to utilities looking to utilize these renewable energy supplies and, in California, efforts are being made to streamline the approval processes for new CSP plants as well.

• New National and DOE incentives are aimed at expanding the scope of Biomass/Biogas to include the development of other advanced biofuels that will contribute to the requirements of the Renewable Fuels Standard (RFS).The largest problem facing the geothermal industry is the lack of a Federal policy promoting geothermal development. The economic viability of most geothermal electricity production projects continues to be dependent on the financial support created by state energy policy.

CASE STUDIES

http://www.osti.gov/accomplishments/NRELprofiles.htmlUtility-Scale Case Studies (OSTI, NREL):