WORLD CLASS FIRE DETECTION PRODUCTS
Designed and Manufactured in South Africa
ABOUT ZYTEQ FIRE
• ZYTEQ Fire was founded in 2014 by former Management and Staff of a well known fire detection manufacturer in Cape Town
• Our business has received financial support from the DTI and the IDC
• Our Staff own 16% of the manufacturing business through the ZYTEQ Workers Trust
• We are a privately owned Company
• Our Mission is to provide our clients with World Class Products that are of the highest quality, cost competitive and easy to use with the customer support clients deserve
• We design and manufacture our own detection products and partner with companies such as Global Fire Equipment to provide full system solutions
www.zyteqfire.com 2
ZYTEQ FIRE GALLERY
www.zyteqfire.com 3
ABOUT GLOBAL FIRE EQUIPMENT (GFE)
• Founded in Denmark in 1994
• Currently the headquarters, factory and R&D centre is based in Faro, Portugal in the EU
• Distributors in 80 countries around the world with active installations in over 90 countries
• GFE has their own in-house electronic assembly and plastic injection molding capability
• GFE equipment is known for proven reliability and ease of use
• All GFE panels carry a lifetime warranty
• ZYTEQ Fire is a technology partner of GFE and uses the GFE ZEOS digital addressable protocol in our detectors
www.zyteqfire.com 4
ANALOGUE / ADDRESSABLE SYSTEM
www.zyteqfire.com 5
Besides device condition (analogue value), panel monitors device presence and type in order to report any installation change that might be unwarranted. This control is required by EN54.
Communication between panel and devices is supported by proprietaryprotocols which enable information flow in token ring topology.
ZYTEQ FIREPRODUCT RANGE
MAIN CATEGORIES
• Panels:
– Addressable and Conventional
• Devices:
– Detection, Signaling, Monitor/Command, Protection/Power
• Communication Interfaces
– RS422, TCP/IP, Fibre
• Software
– Configuration and supervision
www.zyteqfire.com 7
ZYTEQ FIRE PANELS
PANEL RANGE
www.zyteqfire.com 9
CONVENTIONALEXTINGUISHINGADDRESSABLE
ZYTEQ FIREADDRESSABLE PANELS
GEKKO PANEL
www.zyteqfire.com 11
• System up to 4 Loops
• System loop capacity up to 128 loops
• Max. 250 devices per loop
• 125 addresses per loop
• Graphical LCD display
• Micro-USB communication port
• Increased processing power
• 10000 event log memory
• More cause effect programming options
• Networkable up to 32 panels via Copper, TCP/IP and Fibre (mono and multi-mode)
OCTO+ PANEL
www.zyteqfire.com 12
• System loop capacity up to 128 loops
• Up to 4 loops
• Max. 250 devices per loop
• 125 addresses per loop
• Graphical LCD display
• Hybrid P2P Advanced protocol
• Micro-USB communication port
• Increased processing power
• 10000 event log memory
• Chassis mounted
• Networkable up to 32 panels
NODE+ PANEL
www.zyteqfire.com 13
• Modular expansion of OCTO+ system
• Removable chassis
• Hybrid P2P Advanced protocol
• Firmware upgradable via USB
• Up to 4 loops
• Reversible Door for side-by-side installation
CHAMELEON MINI REPEATER PANEL
www.zyteqfire.com 14
• In a Chameleon Network, a Chameleon Repeater is a “Global System Repeater”.
• It works as a complete addressed master panel and processes “all system” info. It is a Panel “without devices” or Sounders.
• With and without PSU.
• Necessary to close communication ring.
• RS422, TCP/IP & Fiber-optic communications.
CHAMELEON DISPLAY PANEL
www.zyteqfire.com 15
• Everything that is displayed in the Panel “Front end” are copied to the “Chameleon Display”. It acts as a “mirror”.
• Doesn´t have a dedicated network address.
• Not necessary to close communication ring.
• Chameleon Display can be used with OCTO+, GEKKO and NODE+ panels.
ZYTEQ FIRECONVENTIONAL PANELS
FIGHTER MPR
www.zyteqfire.com 17
• Menu driven conventional fire alarm and extinguishing panel using 4-wire Bus technology expandability RS-485, permitting flexible and cost optimized installations.
• Zones & Output expandability: 8 to 72 inputs and outputs.
• Extinguishing operation: 2 Extinguishing areas with 4 Zones each.
• LCD keypad units for supervision, monitoring, operation and programming.
• Built in communicator.
• Intellizone operation (Alarm verification).
• LOG (events): Storage of up to 1.000 log events.
• Remote supervision, monitoring, operation and programming.
FIGHTER KSDA
www.zyteqfire.com 18
• Stand alone Keypad / Repeater
• Menu-driven programming for easy system setup (installer)
• 3 LEDs indicate the status of the power
supply, alarms and faults of the system
• Complete supervision, monitoring, operation and programming.
• Evacuation Command with keys combination (1 + 3 key buttons)
• Interconnection via RS-485 BUS system
• Dimensions (HxWxD [cm]): 11 x 15.5 x 2.5 cm
ORION & ORION MINI
www.zyteqfire.com 19
• 1, 2, 4 and 8 zones versions.
• Max. 32 detection devices per zone.
• Active end-of-line monitoring.
• 1/2 sounder circuit outputs.
• Zone delay operation.
• Auxiliary supply output.
• Repeater panel output.
ORION MINI REPEATER
www.zyteqfire.com 20
• Provides remote control, system status and monitoring
• Control access levels 1 and 2
• Up to 4 ORION MINI REP per Orion system
• Interconnection via RS232
• Compatible with Data Loop interfaces
ZYTEQ FIRECONVENTIONALEXTINGUISHING PANELS
FIGHTER XT
www.zyteqfire.com 22
• Extinguishing operation, 1 extinguishing area with 8 zones.
• Menu driven conventional fire alarm and extinguishing panel using4-wire Bus technology expandability RS-485.
• Zones & Output expandability: 8 to 72 inputs and outputs.
• Cross-zoning/extinguishing operation.
• LCD keypad units for supervision, monitoring, operation and programming.
• Built in communicator.
• Intellizone operation (Alarm verification).
• LOG (events): Storage of up to 1.000 log events.
• Remote supervision, monitoring, operation and programming.
ORION EX
www.zyteqfire.com 23
• 4 Fire Detection Zones: 2 crossed Zones and 1 individual Zone linked with automatic extinguishing cycle
• 1 Zone dedicated only for fire detection which doesn’t activates automatic extinguishing cycle
• Up to 32 conventional devices
• Programmable Pre-Release and Extinguishing times
• Monitored inputs for Manual Extinguishing Cycle Activation and Remote Abort
• Electrovalve solenoid and Weight / Flow / Pressure Switch Status monitoring
• Additional outputs via MPX-REL & MPX-SNDR modules
ZYTEQ FIREPOWER SUPPLIES
GFE-BCM
www.zyteqfire.com 25
• Fault Reay
• Battery Monitorization
• Inverted Polarity Protection
• Versions with 1.7A & 2.4A (BCM-3)
• Versions with 5A & 10A (BCM-5/10)
• Monitored through analogue loop via built-in I/O
ZYTEQ FIREDEVICES: DETECTION
DETECTION
www.zyteqfire.com 27
DETECTORS:
• Optical Smoke and Heat combination
• Combination Sounder Beacon
• Linear Heat Cable
• Gas
• Aspiration
• Flame
MANUAL CALL POINTS:
• Resettable
• Hinged flap
• Weatherproof Versions
MODULES:
• ZMU – Zone Monitoring Unit
• LSC ISO – Loop Sounder Controller
• AD ISO – Line Isolator
• I/O – Input/Output Module
• MAM (Manual Addressable Module)
ZYTEQ FIRE DETECTOR RANGE
www.zyteqfire.com 28
• Addressable and Conventional Versions
• Unique serial number per device stored in memory
• Dual LED’s for 360 visibility
• Elegant Styling
• Drift Compensation
• Integrated design (Smoke/Heat detection, Sounder, and Beacon in a single device)
• Rate of Rise Heat Detection
• Access to detector data via RFID reader and smartphone App
• Compliant with EN54 standard for Smoke, Heat, Sounders, and Beacons
ZA831ZC931
ZA830ZC910/20
DETECTOR ACCESSORIES
www.zyteqfire.com 29
REMOTE INDICATOR:
• Conventional:
– Hard wired to detector
• Addressable:
– Loop device with same addressas detector
ZYTEQ FIRE LINE MODULES & CALL POINTS
MANUAL CALLPOINT
www.zyteqfire.com 31
• Approximately 1 second response
• Resettable with key
• Weatherproof IP67 Version
• Low Profile Adapter Plate
MODULES
www.zyteqfire.com 32
ZMU – ZONE MONITORING UNIT:
• Single to Quad models
• Monitored interface module
• Loop Isolator built in
• Quad model requires external supply
• Various response type selection
MODULES
www.zyteqfire.com 33
CONTROL I/O:
• 1, 2 and 3 relay output options
• Loop Powered
• Loop Isolator built in
• Programmable Delays
• Built-in short circuit isolator (3 I/O-Plus)
• MAINS I/O option with 8A relay contact rating
• Sprinkler activation monitoring
• Loop powered
• Local disablement key
MODULES
www.zyteqfire.com 34
MONITORING (INPUT):
• 1, 2, 3, 4 and 8 input options
• Loop Powered
• Programmable Delays
• Built-in short circuit isolator
• Status LED’s indicator
• Small size (MAM-R)
MODULES
www.zyteqfire.com 35
WHITE:Smoke / Heat Detector Interface
YELLOW:Sounder or Micro-Output
RED:MCP or Micro-Input
MONITORING M.A.M:
DOORHOLDER
www.zyteqfire.com 36
GFE-DHA:
• Addressable door holder
• Loop powered
• Monitored
• 200N magnetic force
GFE-DHC:
• Conventional door holder
• Powered externally
• 400N magnetic force
ZYTEQ FIRE DEVICES: NOTIFICATION
SOUNDERS & BEACONS
www.zyteqfire.com 38
• Valkerie Voice, Sounder and Beacon range
• Fully synchronized
• IP65 versions
• Various colour options
• LSC-ISO: amplifier for sounder integration
• Yellow MAM: Conventional sounder addressing
• Industrial range
• Zyteq Sounder Beacon: I/O Triggered
VALKERIE VOX
www.zyteqfire.com 39
• Addressable voice sounder
• Loop controlled and powered
• IP65 versions
• Broadcast 5 different messages
• Pre-Defined or Propriety messages
• Message recording application
• Industrial range
• Zyteq Sounder Beacon: I/O Triggered
ZYTEQ FIRE SOFTWARE
CHAMELEON CONNECTOR
www.zyteqfire.com 41
• More cause-effect programming• Micro-USB connection• Firmware update• Retrieve panel event log• NEXT UPDATE:
• Retrieve loop population• Configuration Export (Excel)
VOX LOADER
www.zyteqfire.com 42
• Record/edit voice messages• Multi-language configurations• Download messages to sounders
ODYSSEY
www.zyteqfire.com 43
• Monitor/control up to 64 GEKKO or OCTO+ systems
• Protocol transmits all information to PC• 100% control, including diagnostic
features.• E-mail & SMS notifications• Remote evacuation