Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
FS
FS
FSFS
FS
1.6 1.4
C
D
STAIR C
1-W111
CORRIDOR
1-W112
MEN
1-W113
WOMEN
1-W114
BREAK ROOM
1-W115
A300 SA
10"ØA
300 SA
10"Ø
A300 SA
10"ØA
300 SA
10"Ø
20"x12" SA
AH
1-1
D50 SA
6"ØD
50 SA
6"Ø
C100 EA
8"Ø C100 EA
8"Ø
EUH
A-10
10"x8" EA
FDFD
10" x 8" SA
10"
x 8
" S
A
10" x 8" S
A
M16
1"ø CD1"ø CD UP
RL RS
M15
M19
1"ø CD
M16
M19
GENERAL NOTESGENERAL NOTES APPLY TO ALL SHEETS IN THE SERIES THAT THEY ARE ON.
EACH SERIES OF SHEETS WILL START OVER AT NOTE 1.
KEY NOTESKEY NOTES ARE NUMBERED SEQUENTIALLY FROM M1 TO THE LAST KEY NOTE.
THEY ARE PROJECT SPECIFIC. ONLY THE KEY NOTES USED ON THIS SHEET WILL
BE LISTED.
1. COORDINATE LOCATIONS OF ALL EQUIPMENT AND ROUTING OF
ALL DUCTWORK AND PIPING WITH OTHER TRADES PRIOR TO ANY
ROUGH IN. PROVIDE
OFFSETS AND TRANSITIONS WHERE REQUIRED TO ACCOMODATE
BUILDING CONDITIONS AND PRESERVE HEADROOM.
22.924
P
Q
R
S
MHE SHAFT C
2-W250
STAIR H
1-W151
ELECTRICAL
2-W253
JANITOR
2-W255
WOMEN
2-W256
MEN
2-W257
BREAK ROOM
2-W258
A200 SA
10"Ø
A200 SA
10"ØA
200 SA
10"Ø
D50 SA
6"Ø
C100 EA
8"Ø
C100 EA
8"ØD
50 SA
6"Ø
10"x10" SA
16"x12" SA
AH2-3
20"x14" SA UP/DN
24"x16" EA UP/DN
EUHG-2B
AC11A
AC
11B
AC
11C
EUH
G-2C
EUH
G-2D
M7
AH
3-3
AH
4-3
FD
10"x
8"
EA
C50 EA
8"Ø
10"x
8"
SA
FD
8"x8"P
150 EA
M17
M17
3/4"ø CD
RL
RS
3/4"ø CD
RS UP
RL UP
M19
1213
ELEV 1
1-W104
STAIR A
1-W105
BREAK ROOM
2-W204
MHE SHAFT A
2-W202VESTIBULE
2-W203
AH
2-4
AH
3-4
AH
4-4
AH
5-4
8"ø SA
A200 SA
10"ØA
200 SA
10"Ø
A200 SA
10"ØA
200 SA
10"Ø
16" x 12" SA
FD
3/4"ø CD
M19M15
1.6 1.4
C
D
E
AH2-1
AH
3-1
AH
4-1M7
STAIR C
1-W111
MEN
2-W213WOMEN
2-W214
BREAK ROOM
2-W215
A200 SA
10"Ø
A200 SA
10"Ø
A200 SA
10"ØA
200 SA
10"Ø
16" x 12" SA
10" x 8" SA
FD
FD
FD
10"
x 8
" S
A
8"
x 6
" S
A
150 SA
6"Ø
150 SA
6"Ø
M17
RL UP
RS UPTYP. 5
RISERS
3/4"ø CD
RS
RL
43"x11" RA
M19
M15
C100 EA
8"Ø
C100 EA
8"Ø
22.924
P
Q
R
S
MHE SHAFT C
1-W150
STAIR H
1-W151
ELECTRICAL
1-W153
JANITOR
1-W155
WOMEN
1-W156
MEN
1-W157
BREAK ROOM
1-W158
EUHG-2A
AC
17
10"x10" SA
10"x
8"
SA
10"ø
SA
10"ø SA
A200 SA
10"Ø
A200 SA
10"ØA
200 SA
10"Ø
A200 SA
10"Ø
AH
1-3
C100 EA
8"ØD
50 SA
6"Ø
D50 SA
6"ØC
100 EA
8"Ø
EMERGENCY
ELEC ROOM
1-W154
AC
26
EUH
F-3
8"ø EA
C50 EA
8"Ø
EUHA-3
FDFD
10"
x 8
" E
A
16"x12" SA
M17
3/4"ø CD
3/4"ø CD
3/4"ø CD
12"x6"E
TA
RS UP
RL UP
RS RL
3/4"ø CD
M19
8"x8"P
150 EA
FDFD
1.6 1.4
D
E
AH5-1
MEN
5-W513WOMEN
5-W514
BREAK ROOM
5-W515
A350 SA
10"Ø
A350 SA
10"Ø
20" x 12" SA
10"
x 8
" S
A
8"
x 6
" S
A
1100 SA
6"Ø
M17
RL UP
RL UPTYP. 5
RISERS
RL
RL
12"ø SA
C100 EA
8"Ø
C100 EA
8"Ø
1100 SA
6"Ø
A350 SA
10"Ø
A350 SA
10"Ø
25"x22" SA
13"x32" RA
16"x24" EA
20"x14" SADUCTWORK
RISERS TO
ERU-3
M15
M19
22.924
P
Q
R
S
EUHG-2E
AC
11D
AH
5-3
STAIR H
1-W151
ELEC
5-W553
JANITOR
5-W555
WOMEN
5-W556
MEN
5-W557
BREAK ROOM
5-W558
A350 SA
10"Ø
A350 SA
10"ØA
350 SA
10"Ø
1100 SA
6"Ø
C100 EA
8"Ø
C100 EA
8"Ø1
100 SA
6"Ø
20"x12" RA
20"x14" SA DN24"x16" EA DN
10"x
8"
EA
C100 EA
8"Ø
10"x
8"
SA
M17
RL
RL
24"x16" EA
20"x14" SA
25"x22" SA
13"x32" RA
DUCTWORK
RISER TO
ERU-2
The
Co
ntr
ac
tor
sha
ll v
erif
y a
nd
be
re
spo
nsi
ble
fo
r a
ll d
ime
nsi
on
s. D
O N
OT
sca
le t
he
dra
win
g -
an
y e
rro
rs o
r o
mis
sio
ns
sha
ll b
e r
ep
ort
ed
to
Sta
nte
c w
itho
ut
de
lay.
The
Co
pyrig
hts
to
all
de
sig
ns
an
d d
raw
ing
s a
re t
he
pro
pe
rty o
f St
an
tec
. R
ep
rod
uc
tion
or
use
fo
r a
ny p
urp
ose
oth
er
tha
n t
ha
t a
uth
oriz
ed
by
Sta
nte
c is
fo
rbid
de
n.
ORIGINAL SHEET - ARCH E1
Drawing No.
Revision:
Permit/Seal
Title
Issu
ed
/Re
vis
ion
YY
YY
.MM
.DD
DATE:
Clie
nt/
Pro
jec
t
Project No.:
Co
nsu
lta
nt
Scale:
1
A
2 3 4 5 6
B
C
D
E
Key Plan:
AB
DC
N
4/2
8/2
020
1:4
5:2
2 P
M 6
As indicated
M402.2
2019.10.23
PR
OJE
CT
DIA
MO
ND
-FU
LFIL
LMEN
T C
EN
TER
Pa
na
tto
ni D
ev
elo
pm
en
tC
om
pa
ny, In
c.
ENLARGED PLANS -HVAC
218011482
Sta
nte
c A
rch
ite
ctu
re a
nd
En
gin
ee
ring
LLC
65
0 S
mit
hfie
ld S
tre
et
Suit
e 2
500
Pitts
bu
rgh
, P
A
152
22-3
90
0
Tel:
(412
) 394
-7000
•w
ww
.sta
nte
c.c
om
1/8" = 1'-0"M402.2
B4
ENLARGED PLAN - LEVEL 1 - REMOTE
BREAKROOM - STAIR C - HVAC
M7 PROVIDE FIRE/SMOKE DAMPER AT 2ND FLOOR SLAB PENETRATION.
M15 1" CD RISER TO HUB DRAIN ON GROUND FLOOR. COORDINATE WITH
PLUMBING.
M16 ROUTE 3/4" CD TO HUB DRAIN. COORDINATE WITH PLUMBING.
M17 ROUTE 3/4" CD TO MOP SINK IN JANITOR'S CLOSET.
M19 PROVIDE CLEANOUTS AT EVERY DIRECTION CHANGE OF CD PIPING.
1/8" = 1'-0"M402.2
C1
ENLARGED PLAN - LEVEL 2-4 - REMOTE
BREAKROOM - STAIR H - HVAC
1/8" = 1'-0"M402.2
A4 ENLARGED PLAN - LEVEL 2-5 - REMOTE BREAKROOM - STAIR A - HVAC
1/8" = 1'-0"M402.2
B2
ENLARGED PLAN - LEVEL 2-4 - REMOTE
BREAKROOM - STAIR C - HVAC1/8" = 1'-0"M402.2
A1
ENLARGED PLAN - LEVEL 1 - REMOTE
BREAKROOM - STAIR H - HVAC
PER
MIT
SET
201
9.1
2.1
2
1IS
SUED
FO
R C
ON
STR
UC
TIO
N2
020
.01
.09
6C
HA
NG
E B
ULL
ETIN
#5
202
0.0
4.2
3
1/8" = 1'-0"M402.2
1
ENLARGED PLAN - LEVEL 5 - REMOTE
BREAKROOM - STAIR C - HVAC
6
6
1/8" = 1'-0"M402.2
2
ENLARGED PLAN - LEVEL 5 - REMOTE
BREAKROOM - STAIR H - HVAC
6
6