1
FS FS FS FS FS 1.6 1.4 C D STAIR C 1-W111 CORRIDOR 1-W112 MEN 1-W113 WOMEN 1-W114 BREAK ROOM 1-W115 A 300 SA 10"Ø A 300 SA 10"Ø A 300 SA 10"Ø A 300 SA 10"Ø 20"x12" SA AH 1-1 D 50 SA 6"Ø D 50 SA 6"Ø C 100 EA 8"Ø C 100 EA 8"Ø EUH A-10 10"x8" EA FD FD 10" x 8" SA 10" x 8" SA 10" x 8" SA M16 1"ø CD 1"ø CD UP RL RS M15 M19 1"ø CD M16 M19 GENERAL NOTES GENERAL NOTES APPLY TO ALL SHEETS IN THE SERIES THAT THEY ARE ON. EACH SERIES OF SHEETS WILL START OVER AT NOTE 1. KEY NOTES KEY NOTES ARE NUMBERED SEQUENTIALLY FROM M1 TO THE LAST KEY NOTE. THEY ARE PROJECT SPECIFIC. ONLY THE KEY NOTES USED ON THIS SHEET WILL BE LISTED. 1. COORDINATE LOCATIONS OF ALL EQUIPMENT AND ROUTING OF ALL DUCTWORK AND PIPING WITH OTHER TRADES PRIOR TO ANY ROUGH IN. PROVIDE OFFSETS AND TRANSITIONS WHERE REQUIRED TO ACCOMODATE BUILDING CONDITIONS AND PRESERVE HEADROOM. 22.9 24 P Q R S MHE SHAFT C 2-W250 STAIR H 1-W151 ELECTRICAL 2-W253 JANITOR 2-W255 WOMEN 2-W256 MEN 2-W257 BREAK ROOM 2-W258 A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø D 50 SA 6"Ø C 100 EA 8"Ø C 100 EA 8"Ø D 50 SA 6"Ø 10"x10" SA 16"x12" SA AH 2-3 20"x14" SA UP/DN 24"x16" EA UP/DN EUH G-2B AC 11A AC 11B AC 11C EUH G-2C EUH G-2D M7 AH 3-3 AH 4-3 FD 10"x8" EA C 50 EA 8"Ø 10"x8" SA FD 8"x8" P 150 EA M17 M17 3/4"ø CD RL RS 3/4"ø CD RS UP RL UP M19 12 13 ELEV 1 1-W104 STAIR A 1-W105 BREAK ROOM 2-W204 MHE SHAFT A 2-W202 VESTIBULE 2-W203 AH 2-4 AH 3-4 AH 4-4 AH 5-4 8"ø SA A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø 16" x 12" SA FD 3/4"ø CD M19 M15 1.6 1.4 C D E AH 2-1 AH 3-1 AH 4-1 M7 STAIR C 1-W111 MEN 2-W213 WOMEN 2-W214 BREAK ROOM 2-W215 A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø 16" x 12" SA 10" x 8" SA FD FD FD 10" x 8" SA 8" x 6" SA 1 50 SA 6"Ø 1 50 SA 6"Ø M17 RL UP RS UP TYP. 5 RISERS 3/4"ø CD RS RL 43"x11" RA M19 M15 C 100 EA 8"Ø C 100 EA 8"Ø 22.9 24 P Q R S MHE SHAFT C 1-W150 STAIR H 1-W151 ELECTRICAL 1-W153 JANITOR 1-W155 WOMEN 1-W156 MEN 1-W157 BREAK ROOM 1-W158 EUH G-2A AC 17 10"x10" SA 10"x8" SA 10"ø SA 10"ø SA A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø A 200 SA 10"Ø AH 1-3 C 100 EA 8"Ø D 50 SA 6"Ø D 50 SA 6"Ø C 100 EA 8"Ø EMERGENCY ELEC ROOM 1-W154 AC 26 EUH F-3 8"ø EA C 50 EA 8"Ø EUH A-3 FD FD 10" x 8" EA 16"x12" SA M17 3/4"ø CD 3/4"ø CD 3/4"ø CD 12"x6" E TA RS UP RL UP RS RL 3/4"ø CD M19 8"x8" P 150 EA FD FD 1.6 1.4 D E AH 5-1 MEN 5-W513 WOMEN 5-W514 BREAK ROOM 5-W515 A 350 SA 10"Ø A 350 SA 10"Ø 20" x 12" SA 10" x 8" SA 8" x 6" SA 1 100 SA 6"Ø M17 RL UP RL UP TYP. 5 RISERS RL RL 12"ø SA C 100 EA 8"Ø C 100 EA 8"Ø 1 100 SA 6"Ø A 350 SA 10"Ø A 350 SA 10"Ø 25"x22" SA 13"x32" RA 16"x24" EA 20"x14" SA DUCTWORK RISERS TO ERU-3 M15 M19 22.9 24 P Q R S EUH G-2E AC 11D AH 5-3 STAIR H 1-W151 ELEC 5-W553 JANITOR 5-W555 WOMEN 5-W556 MEN 5-W557 BREAK ROOM 5-W558 A 350 SA 10"Ø A 350 SA 10"Ø A 350 SA 10"Ø 1 100 SA 6"Ø C 100 EA 8"Ø C 100 EA 8"Ø 1 100 SA 6"Ø 20"x12" RA 20"x14" SA DN 24"x16" EA DN 10"x8" EA C 100 EA 8"Ø 10"x8" SA M17 RL RL 24"x16" EA 20"x14" SA 25"x22" SA 13"x32" RA DUCTWORK RISER TO ERU-2 The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. ORIGINAL SHEET - ARCH E1 Drawing No. Revision: Permit/Seal Title Issued/Revision YYYY.MM.DD DATE: Client/Project Project No.: Consultant Scale: 1 A 2 3 4 5 6 B C D E Key Plan: A B D C N 4 / 2 8 / 2 0 2 0 1 : 4 5 : 2 2 P M 6 As indicated M402.2 2019.10.23 PROJECT DIAMOND - FULFILLMENT CENTER Panattoni Development Company, Inc. ENLARGED PLANS - HVAC 218011482 Stantec Architecture and Engineering LLC 650 Smithfield Street Suite 2500 Pittsburgh, PA 15222-3900 Tel: (412) 394-7000 • www.stantec.com 1/8" = 1'-0" M402.2 B4 ENLARGED PLAN - LEVEL 1 - REMOTE BREAKROOM - STAIR C - HVAC M7 PROVIDE FIRE/SMOKE DAMPER AT 2ND FLOOR SLAB PENETRATION. M15 1" CD RISER TO HUB DRAIN ON GROUND FLOOR. COORDINATE WITH PLUMBING. M16 ROUTE 3/4" CD TO HUB DRAIN. COORDINATE WITH PLUMBING. M17 ROUTE 3/4" CD TO MOP SINK IN JANITOR'S CLOSET. M19 PROVIDE CLEANOUTS AT EVERY DIRECTION CHANGE OF CD PIPING. 1/8" = 1'-0" M402.2 C1 ENLARGED PLAN - LEVEL 2-4 - REMOTE BREAKROOM - STAIR H - HVAC 1/8" = 1'-0" M402.2 A4 ENLARGED PLAN - LEVEL 2-5 - REMOTE BREAKROOM - STAIR A - HVAC 1/8" = 1'-0" M402.2 B2 ENLARGED PLAN - LEVEL 2-4 - REMOTE BREAKROOM - STAIR C - HVAC 1/8" = 1'-0" M402.2 A1 ENLARGED PLAN - LEVEL 1 - REMOTE BREAKROOM - STAIR H - HVAC P E R M I T S E T 2 0 1 9 . 1 2 . 1 2 1 I S S U E D F O R C O N S T R U C T I O N 2 0 2 0 . 0 1 . 0 9 6 C H A N G E B U L L E T I N # 5 2 0 2 0 . 0 4 . 2 3 1/8" = 1'-0" M402.2 1 ENLARGED PLAN - LEVEL 5 - REMOTE BREAKROOM - STAIR C - HVAC 6 6 1/8" = 1'-0" M402.2 2 ENLARGED PLAN - LEVEL 5 - REMOTE BREAKROOM - STAIR H - HVAC 6 6

M402csdocs.comfortar.com/Sean/Jobs Working/20-694...100 ea 8"Ø c 100 ea 8"Ø ... mhe shaft c 2-w250 stair h 1-w151 electrical 2-w253 janitor 2-w255 women 2-w256 men break room 2-w258

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: M402csdocs.comfortar.com/Sean/Jobs Working/20-694...100 ea 8"Ø c 100 ea 8"Ø ... mhe shaft c 2-w250 stair h 1-w151 electrical 2-w253 janitor 2-w255 women 2-w256 men break room 2-w258

FS

FS

FSFS

FS

1.6 1.4

C

D

STAIR C

1-W111

CORRIDOR

1-W112

MEN

1-W113

WOMEN

1-W114

BREAK ROOM

1-W115

A300 SA

10"ØA

300 SA

10"Ø

A300 SA

10"ØA

300 SA

10"Ø

20"x12" SA

AH

1-1

D50 SA

6"ØD

50 SA

6"Ø

C100 EA

8"Ø C100 EA

8"Ø

EUH

A-10

10"x8" EA

FDFD

10" x 8" SA

10"

x 8

" S

A

10" x 8" S

A

M16

1"ø CD1"ø CD UP

RL RS

M15

M19

1"ø CD

M16

M19

GENERAL NOTESGENERAL NOTES APPLY TO ALL SHEETS IN THE SERIES THAT THEY ARE ON.

EACH SERIES OF SHEETS WILL START OVER AT NOTE 1.

KEY NOTESKEY NOTES ARE NUMBERED SEQUENTIALLY FROM M1 TO THE LAST KEY NOTE.

THEY ARE PROJECT SPECIFIC. ONLY THE KEY NOTES USED ON THIS SHEET WILL

BE LISTED.

1. COORDINATE LOCATIONS OF ALL EQUIPMENT AND ROUTING OF

ALL DUCTWORK AND PIPING WITH OTHER TRADES PRIOR TO ANY

ROUGH IN. PROVIDE

OFFSETS AND TRANSITIONS WHERE REQUIRED TO ACCOMODATE

BUILDING CONDITIONS AND PRESERVE HEADROOM.

22.924

P

Q

R

S

MHE SHAFT C

2-W250

STAIR H

1-W151

ELECTRICAL

2-W253

JANITOR

2-W255

WOMEN

2-W256

MEN

2-W257

BREAK ROOM

2-W258

A200 SA

10"Ø

A200 SA

10"ØA

200 SA

10"Ø

D50 SA

6"Ø

C100 EA

8"Ø

C100 EA

8"ØD

50 SA

6"Ø

10"x10" SA

16"x12" SA

AH2-3

20"x14" SA UP/DN

24"x16" EA UP/DN

EUHG-2B

AC11A

AC

11B

AC

11C

EUH

G-2C

EUH

G-2D

M7

AH

3-3

AH

4-3

FD

10"x

8"

EA

C50 EA

8"Ø

10"x

8"

SA

FD

8"x8"P

150 EA

M17

M17

3/4"ø CD

RL

RS

3/4"ø CD

RS UP

RL UP

M19

1213

ELEV 1

1-W104

STAIR A

1-W105

BREAK ROOM

2-W204

MHE SHAFT A

2-W202VESTIBULE

2-W203

AH

2-4

AH

3-4

AH

4-4

AH

5-4

8"ø SA

A200 SA

10"ØA

200 SA

10"Ø

A200 SA

10"ØA

200 SA

10"Ø

16" x 12" SA

FD

3/4"ø CD

M19M15

1.6 1.4

C

D

E

AH2-1

AH

3-1

AH

4-1M7

STAIR C

1-W111

MEN

2-W213WOMEN

2-W214

BREAK ROOM

2-W215

A200 SA

10"Ø

A200 SA

10"Ø

A200 SA

10"ØA

200 SA

10"Ø

16" x 12" SA

10" x 8" SA

FD

FD

FD

10"

x 8

" S

A

8"

x 6

" S

A

150 SA

6"Ø

150 SA

6"Ø

M17

RL UP

RS UPTYP. 5

RISERS

3/4"ø CD

RS

RL

43"x11" RA

M19

M15

C100 EA

8"Ø

C100 EA

8"Ø

22.924

P

Q

R

S

MHE SHAFT C

1-W150

STAIR H

1-W151

ELECTRICAL

1-W153

JANITOR

1-W155

WOMEN

1-W156

MEN

1-W157

BREAK ROOM

1-W158

EUHG-2A

AC

17

10"x10" SA

10"x

8"

SA

10"ø

SA

10"ø SA

A200 SA

10"Ø

A200 SA

10"ØA

200 SA

10"Ø

A200 SA

10"Ø

AH

1-3

C100 EA

8"ØD

50 SA

6"Ø

D50 SA

6"ØC

100 EA

8"Ø

EMERGENCY

ELEC ROOM

1-W154

AC

26

EUH

F-3

8"ø EA

C50 EA

8"Ø

EUHA-3

FDFD

10"

x 8

" E

A

16"x12" SA

M17

3/4"ø CD

3/4"ø CD

3/4"ø CD

12"x6"E

TA

RS UP

RL UP

RS RL

3/4"ø CD

M19

8"x8"P

150 EA

FDFD

1.6 1.4

D

E

AH5-1

MEN

5-W513WOMEN

5-W514

BREAK ROOM

5-W515

A350 SA

10"Ø

A350 SA

10"Ø

20" x 12" SA

10"

x 8

" S

A

8"

x 6

" S

A

1100 SA

6"Ø

M17

RL UP

RL UPTYP. 5

RISERS

RL

RL

12"ø SA

C100 EA

8"Ø

C100 EA

8"Ø

1100 SA

6"Ø

A350 SA

10"Ø

A350 SA

10"Ø

25"x22" SA

13"x32" RA

16"x24" EA

20"x14" SADUCTWORK

RISERS TO

ERU-3

M15

M19

22.924

P

Q

R

S

EUHG-2E

AC

11D

AH

5-3

STAIR H

1-W151

ELEC

5-W553

JANITOR

5-W555

WOMEN

5-W556

MEN

5-W557

BREAK ROOM

5-W558

A350 SA

10"Ø

A350 SA

10"ØA

350 SA

10"Ø

1100 SA

6"Ø

C100 EA

8"Ø

C100 EA

8"Ø1

100 SA

6"Ø

20"x12" RA

20"x14" SA DN24"x16" EA DN

10"x

8"

EA

C100 EA

8"Ø

10"x

8"

SA

M17

RL

RL

24"x16" EA

20"x14" SA

25"x22" SA

13"x32" RA

DUCTWORK

RISER TO

ERU-2

The

Co

ntr

ac

tor

sha

ll v

erif

y a

nd

be

re

spo

nsi

ble

fo

r a

ll d

ime

nsi

on

s. D

O N

OT

sca

le t

he

dra

win

g -

an

y e

rro

rs o

r o

mis

sio

ns

sha

ll b

e r

ep

ort

ed

to

Sta

nte

c w

itho

ut

de

lay.

The

Co

pyrig

hts

to

all

de

sig

ns

an

d d

raw

ing

s a

re t

he

pro

pe

rty o

f St

an

tec

. R

ep

rod

uc

tion

or

use

fo

r a

ny p

urp

ose

oth

er

tha

n t

ha

t a

uth

oriz

ed

by

Sta

nte

c is

fo

rbid

de

n.

ORIGINAL SHEET - ARCH E1

Drawing No.

Revision:

Permit/Seal

Title

Issu

ed

/Re

vis

ion

YY

YY

.MM

.DD

DATE:

Clie

nt/

Pro

jec

t

Project No.:

Co

nsu

lta

nt

Scale:

1

A

2 3 4 5 6

B

C

D

E

Key Plan:

AB

DC

N

4/2

8/2

020

1:4

5:2

2 P

M 6

As indicated

M402.2

2019.10.23

PR

OJE

CT

DIA

MO

ND

-FU

LFIL

LMEN

T C

EN

TER

Pa

na

tto

ni D

ev

elo

pm

en

tC

om

pa

ny, In

c.

ENLARGED PLANS -HVAC

218011482

Sta

nte

c A

rch

ite

ctu

re a

nd

En

gin

ee

ring

LLC

65

0 S

mit

hfie

ld S

tre

et

Suit

e 2

500

Pitts

bu

rgh

, P

A

152

22-3

90

0

Tel:

(412

) 394

-7000

•w

ww

.sta

nte

c.c

om

1/8" = 1'-0"M402.2

B4

ENLARGED PLAN - LEVEL 1 - REMOTE

BREAKROOM - STAIR C - HVAC

M7 PROVIDE FIRE/SMOKE DAMPER AT 2ND FLOOR SLAB PENETRATION.

M15 1" CD RISER TO HUB DRAIN ON GROUND FLOOR. COORDINATE WITH

PLUMBING.

M16 ROUTE 3/4" CD TO HUB DRAIN. COORDINATE WITH PLUMBING.

M17 ROUTE 3/4" CD TO MOP SINK IN JANITOR'S CLOSET.

M19 PROVIDE CLEANOUTS AT EVERY DIRECTION CHANGE OF CD PIPING.

1/8" = 1'-0"M402.2

C1

ENLARGED PLAN - LEVEL 2-4 - REMOTE

BREAKROOM - STAIR H - HVAC

1/8" = 1'-0"M402.2

A4 ENLARGED PLAN - LEVEL 2-5 - REMOTE BREAKROOM - STAIR A - HVAC

1/8" = 1'-0"M402.2

B2

ENLARGED PLAN - LEVEL 2-4 - REMOTE

BREAKROOM - STAIR C - HVAC1/8" = 1'-0"M402.2

A1

ENLARGED PLAN - LEVEL 1 - REMOTE

BREAKROOM - STAIR H - HVAC

PER

MIT

SET

201

9.1

2.1

2

1IS

SUED

FO

R C

ON

STR

UC

TIO

N2

020

.01

.09

6C

HA

NG

E B

ULL

ETIN

#5

202

0.0

4.2

3

1/8" = 1'-0"M402.2

1

ENLARGED PLAN - LEVEL 5 - REMOTE

BREAKROOM - STAIR C - HVAC

6

6

1/8" = 1'-0"M402.2

2

ENLARGED PLAN - LEVEL 5 - REMOTE

BREAKROOM - STAIR H - HVAC

6

6