8
Surgery 1 Surgery 2 Work smarter Reprocessing sets costs time and money D-RAD SMART PACK No reprocessing, no waiting

Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

Surgery 1

Surgery 2

Work smarter Reprocessing sets costs time and money

D-RADSMART PACKNo reprocessing, no waiting

Page 2: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

The D-RAD SMART PACK System enables surgeons and supporting staff members to work smarter in the OR and out. The system includes sterile single-use

instrument kits and sterile packaged implants to avoid challenges that exist with traditional reprocessed plate and

screw systems. The intelligent design improves efficiency in and out of the OR without sacrificing the intraoperative

flexibility needed to best treat patients.

Work smarter with the D-RAD SMART PACK™

Challenges with reprocessed plate and screw systemsResources Costly and labor-intensive to clean, sterilize, process and shelve

Downtime Set availability often dictates surgery schedules

Contamination Possible breach of sterility due to poor handling and/or reprocessing

Reliability Sets can arrive in the OR with damaged or missing implants and instruments

Compliance Part and lot numbers should be recorded for all implanted devices but are often difficult to find or read

Page 3: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

1

2

3

4

Surgery 1

Surgery 2

1

21

2 3 4

5

67

8

Single-Use Volar Distal Radius Plating System

Workflow for reprocessed instruments, plates and screws

Instrument, implant and screw collection

Transport for reprocessing

Manual washing

Mechanical washing

1

2

3

4

Inspection

Tray assembly

Sterilization

Transport to storage or OR

5

6

7

8

D-RAD SMART PACK™ Single-Use Volar Distal Radius Plating System

Recycle or dispose of single-use instruments

Transport unused inventory to storage or OR

1

2

Packed with smart benefits Savings No material or labor costs to clean, sterilize and reprocess

Efficiency Ready at a moment’s notice – eliminates set downtime

Safety Eliminates the risk of contamination as a result of poor handling and reprocessing

Reliability Always complete with new instruments and implants

Compliance Chart Stiks® to record part and lot numbers for every implant

Green All packaging and single-use instrumentation is made from recyclable material

Page 4: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

The D-RAD SMART PACK™ System was designed to treat the most commonly plated extra-articular and intra-articular distal radius fractures. The system contains:a Four different single-use kits

b A tray with sterile fasteners and single-use plate templates to assist with kit selection

Single-Use KitsKits include an anatomically-contoured 4-hole volar plate and single-use instrumentsa.

Everything you need to work smarter

Left standard Left wide Right standard Right wide

Page 5: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

Screw and Template TrayCortex Screws, Locking Screws, Locking Pegs and Single-Use Plate Templatesb.

Tamper-evident vials contain sterile inner containers with a screw or peg

The Left and Right Single-Use Plate Template boxes each include a Standard and Wide Plate Template.

Page 6: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

Scre

ws/

Pegs

1.4mm K-wire hole to enable centering of the plate on the diaphysis

2.4mm Variable-Angle Locking Screws

2.4mm Cortex Screws

Packed with smart design features

Anatomically contoured to respect the watershed line while providing reconstructive articular support

(10 – 24mm) (10 – 24mm)

Slotted 1.4mm K-wire hole or slotted screw hole to allow for proximal/distal plate adjustments

1.4mm K-wire holes for distal plate positioning

1.8mm Variable Angle Locking Pegs for bicortical support of the metaphysis while minimizing dorsal soft tissue irritation

(12 – 24mm)

Standard and wide options accommodate varying patient anatomy

WideStandard

VLP™ locking technology enables the use of Cortex Screw, Locking Screws or Locking Pegs within a 30º cone

22mm 27mm

1.6mm

56mm

Volar tilt 24º

Page 7: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

Instrumentation

Sterile Screw/Peg Vials with Chart-Stiks®

• No material or labor costs to clean, sterilize and reprocess • Allows intraoperative flexibility to choose the exact screw length needed for varying anatomy

and fracture patterns• Eliminates screw length confirmation step required for screws retrieved from caddies• Chart-Stiks® included on each vial to facilitate the recording of part and lot numbers

Self-retaining T7 screw driver 1.4mm K-wires assist with plate positioning and reference screw trajectories

Fixed-angle drill guide predetermines screw trajectories

Variable-angle drill guide enables intraoperative screw placement flexibility

Preassembled guide block and plate holder Hooked, laser-etched depth gauge grabs the dorsal cortex

Only one 1.8mm drill required for Cortex Screws, locking screws and locking pegs

Page 8: Work smarter - Smith & Nephew · Work smarter with the D-RAD SMART PACK™ Challenges with reprocessed plate and screw systems Resources Costly and labor-intensive to clean, sterilize,

Smith & Nephew, Inc.7135 Goodlett Farms ParkwayCordova, TN 38016USA

Telephone: 1-901-396-2121Information: 1-800-821-5700Orders/Inquiries: 1-800-238-7538

www.smith-nephew.com

™Trademark of Smith & Nephew. Reg. US Pat. & TM Off. All Trademarks Acknowledged©2014 Smith & Nephew, Inc. All rights reserved.00660 V2 06/14