2
Precautionary Note: The manufacturer will not be responsible for problems resulting from any deviation from the recommended application instructions and the following precautions: CAUTION: Due to the aggressive nature of our shingle sealant strip, please note the following: To avoid shingles sticking in hot sun, do not have the sealant strip make contact with various objects on the roof, until you are ready to nail the shingle in place. Roof Top Loading: Lay shingle bundles flat. Do not bend over the ridge. Roof Deck: • 6" Maximum roof deck boards • Minimum 3 8" plywood • Minimum 7 16" OSB Regardless of deck type used, the roofing installer must: 1. Install the deck material in strict compliance with the deck manufacturer’s instructions. 2. Prevent the deck from getting wet before, during and after installation. Ventilation: Must meet or exceed FHA Minimum Property Standards. Handling: Use extra care in handling shingles when the temperature is below 40°F. Storage: Store in a covered ventilated area at a maximum temperature of 110° F. Protect shingles from weather when stored at the job site. Do not store near steam pipes, radiators, etc. Nails must be corrosion-resistant, 11- or 12-gauge, with heads at least 3 8" in diameter. Staples must be 16-gauge minimum, 15 16" minimum crown width and sufficient length to penetrate ¾" into wood decking or through APA-rated roof sheathing. Staples are to be corrosion protected. All Fasteners must penetrate at least ¾" into the wood deck or completely through plywood sheathing. Notice: Owens Corning recommends the use of nails as the preferred method of attaching shingles to wood decking or other nailable surface. Specialty Eave Flashing: WeatherLock ® underlayment or equivalent eave and flashing membrane applied to a point at least 24" beyond interior wall line. See Fig. 1. Underlayment: Standard slope (4" in 12" or more) Application of underlayment, metal drip edges, and eaves flashing. See Fig. 2. Low slope (2" in 12" to less than 4" in 12") Application of underlayment and metal drip edges. See Fig 2A. Fastener Placement: See Fig. 3. Starter Course Left Rake Application: Cut 35" off from the first bottom starter piece. Fasten the remaining 5" x 13 3 8" to the deck as shown in Fig. 4, followed by a full 13 3 8" x 40” starter piece to the deck with 5 fasteners as shown. Right Rake Application: Cut 5" off from the first bottom starter piece. Fasten the remaining 35" x 13 3 8" to the deck as shown in Fig. 4A, followed by a full 13 3 8" x 40" starter piece to the deck with 5 fasteners as shown. Note: Apply Woodcrest ® /Woodmoor ® shingles after WoodStart ® Starter Shingles are installed. Apply Woodcrest ® /Woodmoor ® shingles per the application instructions printed on the shingle wrapper. Made in U.S.A. OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-GET-PINK ® www.roofing.owenscorning.com Pub. No.10011695. Printed in U.S.A. October 2009. THE PINK PANTHER & © 1964–2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. ©2009 Owens Corning. Eaves flashing where required Protector de aleros donde sea necesario WeatherLock WeatherLock ® WeatherLock ® Underlayment Wall line Línea de la pared 24" Beyond interior wall line 24" más allá de la línea de la pared interior Deck Cubierta Slopes 4" in 12" or more Pendientes de 4" en 12" o más 4" min. End lap Traslape final. Mínimo 4" Felt over drip edge at eave Fieltro sobre el borde de escurrimiento en el alero Nails Clavos Drip edge over felt at rake edge Reborde de escurrimiento sobre el fieltro en el borde de caída 2" Top lap Traslape superior de 2" Vertical seams 6' min. Costuras verticales. 6’ como mínimo 1 ½" 5" 1 ½" 40" 1 ¼" Nail Area Área de clavos 1 ¼" Nails Clavos 13 3∕8" WoodStart ® Starter Shingles Installation Instructions Figure 1 Specialty Eave Flashing Figure 2 Underlayment Standard Slope Slopes 2" in 12" to less than 4" in 12" Pendientes 2" en 12" hasta menos de 4" en 12" 19" 19" 17" 36" 19" First and succeeding courses are 36" wide with 19" lap El primero y los tendidos sucesivos son de 36" de ancho con traslape de 19" Drip edge Borde de escurrimiento Drip edge Borde de escurrimiento 12" End lap Traslape final de 12" Starter strip Tira inicial 19" Wall line Línea de la pared Deck Cubierta Figure 2A Underlayment Low Slope Figure 3 Nail Pattern 5" 35" 40" 40" Install first strip with 35" removed Instaler primera tira retirándole 35" Asphalt saturated felt underlayment Refuerzo de fieltro de asfalto saturado Starter strip is flush with drip edges Tira inicial al ras con los bordes de escurrimiento Nails located in Nail Area Clavos localizados en el área de clavos Drip edge Borde de escurrimiento Deck Cubierta Dripedge Borde de escurrimiento Figure 4 Left Rake Application 5" 35" 40" 40" Install first strip with 5" removed Instaler primera tira retirándole 5" Asphalt saturated felt underlayment Refuerzo de fieltro de asfalto saturado Starter strip is flush with drip edges Tira inicial al ras con los bordes de escurrimiento Nails located in Nail Area Clavos localizados en el área de clavos Drip edge Borde de escurrimiento Deck Cubierta Drip edge Borde de escurrimiento Figure 4A Right Rake Application

WoodStart Starter Shinglespdf.lowes.com/installationguides/047563020786_install.pdf · crown width and suffi cient length to penetrate ¾ " into wood decking or through APA-rated

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WoodStart Starter Shinglespdf.lowes.com/installationguides/047563020786_install.pdf · crown width and suffi cient length to penetrate ¾ " into wood decking or through APA-rated

Precautionary Note: The manufacturer will not be responsible for problems resulting from any deviation from the recommended application instructions and the following precautions:

CAUTION: Due to the aggressive nature of our shingle sealant strip, please note the following: To avoid shingles sticking in hot sun, do not have the sealant strip make contact with various objects on the roof, until you are ready to nail the shingle in place.

Roof Top Loading: Lay shingle bundles fl at. Do not bend over the ridge.

Roof Deck: • 6" Maximum roof deck boards • Minimum 3⁄8" plywood • Minimum 7⁄16" OSB

Regardless of deck type used, the roofi ng installer must: 1. Install the deck material in strict compliance

with the deck manufacturer’s instructions.

2. Prevent the deck from getting wet before, during and after installation.

Ventilation: Must meet or exceed FHA Minimum Property Standards.

Handling: Use extra care in handling shingles when the temperature is below 40°F.

Storage: Store in a covered ventilated area at a maximum temperature of 110° F. Protect shingles from weather when stored at the job site. Do not store near steam pipes, radiators, etc.

Nails must be corrosion-resistant, 11- or 12-gauge, with heads at least 3⁄8" in diameter.

Staples must be 16-gauge minimum, 15⁄16" minimum crown width and suffi cient length to penetrate ¾ " into wood decking or through APA-rated roof sheathing. Staples are to be corrosion protected.

All Fasteners must penetrate at least ¾ " into the wood deck or completely through plywood sheathing.

Notice: Owens Corning recommends the use of nails as the preferred method of attaching shingles to wood decking or other nailable surface.

Specialty Eave Flashing: WeatherLock® underlayment or equivalent eave and fl ashing membrane applied to a point at least 24" beyond interior wall line. See Fig. 1.

Underlayment: Standard slope (4" in 12" or more) Application of underlayment, metal drip edges, and eaves fl ashing. See Fig. 2.

Low slope (2" in 12" to less than 4" in 12") Application of underlayment and metal drip edges. See Fig 2A.

Fastener Placement: See Fig. 3.

Starter Course Left Rake Application: Cut 35" off from the fi rst bottom starter piece. Fasten the remaining 5" x 133⁄8" to the deck as shown in Fig. 4, followed by a full 133⁄8" x 40” starter piece to the deck with 5 fasteners as shown.

Right Rake Application: Cut 5" off from the fi rst bottom starter piece. Fasten the remaining 35" x 133⁄8" to the deck as shown in Fig. 4A, followed by a full 133⁄8" x 40" starter piece to the deck with 5 fasteners as shown.

Note: Apply Woodcrest®/Woodmoor® shingles after WoodStart® Starter Shingles are installed. Apply Woodcrest®/Woodmoor® shingles per the application instructions printed on the shingle wrapper.

Made in U.S.A.

OWENS CORNING ROOFING AND ASPHALT, LLCONE OWENS CORNING PARKWAYTOLEDO, OHIO, USA 43659

1-800-GET-PINK®

www.roofing.owenscorning.com

Pub. No. 10011695. Printed in U.S.A. October 2009. THE PINK PANTHER™ & © 1964–2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. ©2009 Owens Corning.

Eaves flashing where requiredProtector de aleros donde sea necesario

WeatherLockWeatherLock®WeatherLock® Underlayment

Wall lineLínea de la pared

24" Beyond interior wall line24" más allá de lalínea de la pared interior

DeckCubierta

Slopes 4" in 12" or morePendientes de 4" en 12" o más

4" min. End lapTraslape final. Mínimo 4"

Felt over drip edge at eaveFieltro sobre el borde de escurrimiento en el alero

NailsClavos

Drip edge over felt at rake edgeReborde de escurrimiento sobre el fieltro en el borde de caída 2"

Top lapTraslape superior

de 2"

Vertical seams 6' min.Costuras verticales. 6’ como mínimo

1 ½"

5"

1 ½"

40"

1 ¼" Nail AreaÁrea de clavos 1 ¼"

NailsClavos

13 3∕8"

WoodStart® Starter ShinglesInstallation Instructions

Figure 1Specialty Eave Flashing

Figure 2Underlayment Standard Slope

Slopes 2" in 12" to less than 4" in 12"Pendientes 2" en 12" hasta menos de 4" en 12"

19" 19"

17"

36"19"

First and succeeding coursesare 36" wide with 19" lapEl primero y los tendidos sucesivos son de36" de ancho con traslape de 19"

Drip edgeBorde de escurrimiento

Drip edgeBorde de escurrimiento

12" End lapTraslape final de 12"

Starter stripTira inicial

19"

Wall lineLínea de la pared

DeckCubierta

Figure 2AUnderlayment Low Slope

Figure 3Nail Pattern

5"

35"

40"

40"Install first strip with 35" removedInstaler primera tira retirándole 35"

Asphalt saturate

d

felt underlayment

Refuerzo de fieltro

de

asfalto saturado

Starter strip is flushwith drip edgesTira inicial al ras con los bordes de escurrimiento

Nails locatedin Nail AreaClavos localizados en el área de clavos

Drip edgeBorde de escurrimiento

DeckCubierta

DripedgeBorde de escurrimiento

Figure 4Left Rake Application

5"

35"

40"

40"

Install first strip with 5" removedInstaler primera tira retirándole 5"

Asphalt saturated

felt underlaymentRefuerzo de fieltro de

asfalto saturado

Starter strip is flushwith drip edgesTira inicial al ras con los bordes de escurrimiento

Nails locatedin Nail AreaClavos localizados en el área de clavos

Drip edgeBorde de escurrimiento

DeckCubiertaDrip

edgeBorde de escurrimiento

Figure 4ARight Rake Application

Page 2: WoodStart Starter Shinglespdf.lowes.com/installationguides/047563020786_install.pdf · crown width and suffi cient length to penetrate ¾ " into wood decking or through APA-rated

WoodStart® Starter ShinglesInstrucciones Para La Colocacion

Precauciones: El fabricante no se responsabiliza de los problemas que resulten como consecuencia de no seguir las instrucciones de colocación recomendadas y las siguientes precauciones:

PRECAUCIÓN: Debido a la adhesividad de la tira selladora para tejas, tenga en cuenta lo siguiente: Para evitar que las tejas se adhieran con el calor, evite el contacto de las tiras selladoras con otros objetos del techo hasta que esté listo para clavar las tejas.

Montaje de la parte superior del techo: Extienda los paquetes de ripias en forma plana. No doble sobre la cumbrera.

Cubierta del techo:

• Tablas de cubierta del techo de 6" como máximo • Lámina de madera enchapada de 3⁄8" como

mínimo • Tablero de fi bra orientada (OSB) de 7⁄16" como

mínimo.

Independientemente del tipo de cubierta que se use, el instalador de techos debe: 1. Instalar el material de cubierta en estricto

cumplimiento con las instrucciones del fabricante. 2. Evitar que la cubierta se humedezca antes,

durante y después de la instalación.

Ventilación: Debe cumplir o superar los estándares mínimos de inmuebles de la Administración Federal de la Vivienda (Federal Housing Administration, FHA).

Manipulación: Tenga especial cuidado al manipular las ripias cuando la temperatura esté por debajo de 40°F.

Almacenamiento: Almacene en un área cubierta y ventilada a una temperatura máxima de 110ºF. Proteja las ripias de la intemperie cuando las almacene en el sitio de trabajo. No almacene cerca de tuberías de vapor, radiadores, etc.

Los clavos deben ser inoxidables, calibre 11 ó 12 con cabeza al menos de 3⁄8" de diámetro.

Las grapas deben ser de calibre 16 como mínimo, ancho de corona mínimo de 15⁄16" y de sufi ciente longitud para penetrar ¾ " en la cubierta de madera o a través de un revestimiento de techo de capacidad APA. Las grapas deben estar preparadas contra la oxidación.

Todos los sujetadores deben penetrar al menos ¾ " en la cubierta de madera o completamente a través del revestimiento de madera enchapada.

Aviso: Owens Corning recomienda el uso de clavos como el mejor método para sujetar las ripias a la cubierta de madera u otra superfi cie apta para clavar.

Protector de alero especial: Refuerzo WeatherLock® o membrana equivalente de alero y protector aplicada en un punto al menos a 24" más allá de la línea de la pared interior. Vea la fi gura 1.

Refuerzo: Pendiente estándar (4" en 12" o más). Colocación de refuerzo, rebordes metálicos de escurrimiento y refuerzos de alero. Vea la fi gura 2.

Pendiente baja (2" en 12" hasta menos de 4" en 12").

Colocación de refuerzo y rebordes metálicos de escurrimiento. Vea la fi gura 2A.

Colocación de los sujetadores: Vea la fi gura 3.

Tendido inicial Colocación de la caída izquierda: Corte 35" de la primera pieza inicial del fondo. Sujete la pieza restante de 5" x 133⁄8" a la cubierta como se muestra en la fi gura 4, seguida de una pieza inicial completa de 133⁄8" x 40" sujeta a la cubierta mediante 5 sujetadores, como se muestra en el diagrama.

Colocación de la caída derecha: Corte 5" de la primera pieza inicial del fondo. Sujete la pieza restante de 35" x 133⁄8" a la cubierta como se muestra en la fi gura 4A, seguida de una pieza inicial completa de 133⁄8" x 40" sujeta a la cubierta mediante 5 sujetadores, como se muestra en el diagrama.

Nota: Aplique las ripias Woodcrest®/Woodmoor® después de que esté instalada la capa de ripia inicial Woodstarter®. Aplique las ripias Woodcrest®/Woodmoor® de acuerdo a las instrucciones impresas en la envoltura de las mismas.

Hecho en los EE.UU.

Figure 1Protector de alero especial

Figure 3Patrón de clavos

Eaves flashing where requiredProtector de aleros donde sea necesario

WeatherLockWeatherLock®WeatherLock® Underlayment

Wall lineLínea de la pared

24" Beyond interior wall line24" más allá de lalínea de la pared interior

DeckCubierta

Slopes 4" in 12" or morePendientes de 4" en 12" o más

4" min. End lapTraslape final. Mínimo 4"

Felt over drip edge at eaveFieltro sobre el borde de escurrimiento en el alero

NailsClavos

Drip edge over felt at rake edgeReborde de escurrimiento sobre el fieltro en el borde de caída 2"

Top lapTraslape superior

de 2"

Vertical seams 6' min.Costuras verticales. 6’ como mínimo

1 ½"

5"

1 ½"

40"

1 ¼" Nail AreaÁrea de clavos 1 ¼"

NailsClavos

13 3∕8"

Slopes 2" in 12" to less than 4" in 12"Pendientes 2" en 12" hasta menos de 4" en 12"

19" 19"

17"

36"19"

First and succeeding coursesare 36" wide with 19" lapEl primero y los tendidos sucesivos son de36" de ancho con traslape de 19"

Drip edgeBorde de escurrimiento

Drip edgeBorde de escurrimiento

12" End lapTraslape final de 12"

Starter stripTira inicial

19"

Wall lineLínea de la pared

DeckCubierta

5"

35"

40"

40"Install first strip with 35" removedInstaler primera tira retirándole 35"

Asphalt saturate

d

felt underlayment

Refuerzo de fieltro

de

asfalto saturado

Starter strip is flushwith drip edgesTira inicial al ras con los bordes de escurrimiento

Nails locatedin Nail AreaClavos localizados en el área de clavos

Drip edgeBorde de escurrimiento

DeckCubierta

DripedgeBorde de escurrimiento

5"

35"

40"

40"

Install first strip with 5" removedInstaler primera tira retirándole 5"

Asphalt saturated

felt underlaymentRefuerzo de fieltro de

asfalto saturado

Starter strip is flushwith drip edgesTira inicial al ras con los bordes de escurrimiento

Nails locatedin Nail AreaClavos localizados en el área de clavos

Drip edgeBorde de escurrimiento

DeckCubiertaDrip

edgeBorde de escurrimiento

Figure 2Refuerzo de pendiente estándar

Figure 2ARefuerzo de pendiente baja

Figure 4Colocación de caída izquierda

Figure 4AColocación de caída derecha