K-WIRELESS DILATOR TECHNIQUE - A trio of dilators directly paves your way from pedicle awl to screw placement - A smooth and intuitive screw placement procedure - Radiolucent dilator. Better visualization - "Soft tissue-less" field of work - No need for a k-wire - Preload your screwdriver with a pedicle screw, tower, and k-wire - One instrument takes you from skin incision to final screw placement - Less time. Less x-ray exposure ProMIS™ - YOUR CHOICE FOR SCREW PLACEMENT With interchangeable screw placement techniques, you can switch intraoperatively based on your assessment of the situation - The most state-of-the-art screw placement technique with least steps and fewest instruments - An advanced patented screw driver with an integrated k-wire and tower for direct screw placement - The sharp k-wire tip anchors your entry point while you determine desired trajectory; then open the cortical bone for initial screw fixation - Back out the sharp tip at any point during the screw advancement, leaving a blunt-tip pedicle screw which is accurately guided by the native pedicle to its final positioning - Screw is in final position with no exchange of instruments - Less x-ray exposure - Safe k-wire and k-wireless management with full control over tip and screw advancement DIRECT SKIN-TO-SCREW DIRECT SKIN-TO-SCREW TECHNIQUE ROD PLACEMENT - Place the rods, reduce, and close - You're out of the operating room - Robust towers that detach and re-attach easily - In-tower single step reduction - Better leverage and power during compression/distraction ANCHOR GUIDANCE PREPARE ENTRY POINT ESTABLISH TRAJECTORY INSERT SCREW JAMSHIDI TECHNIQUE - Utilize a robust, reusable Jamshidi with an integrated k-wire - Fewer disposable instruments TAP-SHIDI TECHNIQUE - Work with a Tap and an integrated k-wire as you would use a Jamshidi - In the time you place a Jamshidi, you already complete the tapping - Insert the pedicle screw over a k-wire - Fewer steps. Fewer instruments

With interchangeable screw placement techniques, you …premiaspine.com/var/1137/591258-PS_PROmis_flyer_10.pdf · K-WIRELESS DILATOR TECHNIQUE - A trio of dilators directly paves

Embed Size (px)

Citation preview

K-WIRELESS DILATOR TECHNIQUE- A trio of dilators directly paves your way

from pedicle awl to screw placement- A smooth and intuitive screw

placement procedure- Radiolucent dilator. Better visualization- "Soft tissue-less" field of work- No need for a k-wire

- Preload your screwdriver with a pedicle screw, tower, and k-wire

- One instrument takes you from skin incision to final screw placement

- Less time. Less x-ray exposure

ProMIS™ - YOUR CHOICE FOR SCREW PLACEMENTWith interchangeable screw placement techniques, you can switch intraoperatively based on your assessment of the situation

- The most state-of-the-art screw placement technique with least steps and fewest instruments - An advanced patented screw driver with an integrated k-wire and tower for direct screw placement- The sharp k-wire tip anchors your entry point while you determine desired trajectory; then open the cortical

bone for initial screw fixation- Back out the sharp tip at any point during the screw advancement, leaving a blunt-tip pedicle screw which

is accurately guided by the native pedicle to its final positioning- Screw is in final position with no exchange of instruments- Less x-ray exposure- Safe k-wire and k-wireless management with full control over tip and screw advancement

DIRECT SKIN-TO-SCREW

DIRECT SKIN-TO-SCREW TECHNIQUE

ROD PLACEMENT

- Place the rods, reduce, and close - You're out of the operating room- Robust towers that detach and

re-attach easily- In-tower single step reduction- Better leverage and power during

compression/distraction

ANCHOR GUIDANCE

PREPARE ENTRY POINT

ESTABLISH TRAJECTORY

INSERT SCREW

JAMSHIDI TECHNIQUE- Utilize a robust, reusable Jamshidi

with an integrated k-wire- Fewer disposable instruments

TAP-SHIDI TECHNIQUE- Work with a Tap and an integrated

k-wire as you would use a Jamshidi- In the time you place a Jamshidi, you

already complete the tapping- Insert the pedicle screw over a k-wire - Fewer steps. Fewer instruments

- Fewer steps. Faster procedure- Less radiation exposure for operating room staff and patients- Small uniform skin incisions with least muscle trauma- Sterile implants- More economical reprocessing

ProMIS™ Fixation SystemDELIVERS VALUE TO PATIENTS AND HOSPITALS

PATENTED SCREW SURFACEWith documented improvement in screw-bone integration*

INDIVIDUALLY PACKEDSTERILE IMPLANTS

ProMIS™ Fixation System

Competition Premia Spine

Advanced MIS screw placement

* Effect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screw in Vitro and Vivo. Schwartz, Boyan et. al. The Journal of Bone and Joint Surgery. 2OO8. p. 2485-2498

FEWER INSTRUMENTS. MORE ECONOMICAL REPROCESSING

Screw placement tools Reduction tools Rod insertion & fixation tools

Special thanks to Dr. Bernd Illerhaus

CONTACT US

Premia Spine Inc.15OO Market Street, 12th floor East Tower, Philadelphia PA [email protected] | TEL: (215) 2O7-O137