24
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-56300002-01 Printed in U.S.A. Form 30RB-3W Pg 1 12-08 Replaces: New Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* * See Table 1 for modular sizes. POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label Diagram 060-100 All 1 00PSN500030200A 110-190 All 2 00PSN500187100A 210-300 All 3 00PSN500187000A CONTROL SCHEMATICS 30RB Unit Size Voltage Figure Number Label Diagram 060-080 All 4 00PSN500029500A 5 00PSN500029600A 090, 100 All 6 00PSN500190800A 5 00PSN500029600A 110-150 All 6 00PSN500190800A 7 00PSN500029700A 160-190 All 8 00PSN500190900A 7 00PSN500029700A 210-300 All 9 00PSN500191000A 00PSN500029800A COMPONENT ARRANGEMENTS 30RB Unit Size Voltage Connections Control Box Type Figure Number Label Diagram 060,070 208/230 Control/Power Combination 10 SF805094 380, 460, 575 Control/Power Combination 11 SF805091 080-120 208/230 Control Fan Electrical 12 SF805090 Power Power-L 13 SF805095 380, 460, 575 Control/Power Combination 11 SF805091 130-190 208/230 Control Fan Electrical 12 SF805090 Power Power-L 13 SF805095 PE1 15 SF805096 380, 460, 575 with Terminal Block (Standard) Control Fan Electrical 12 SF805090 Power PE1 14 SF805092 380, 460, 575 with Non-Fused Disconnect Option Control Fan Electrical 12 SF805090 Power PE1 14 SF805092 Power-L 13 SF805095 210, 225 208/230 Control Fan Electrical 12 SF805090 Power Power-L 13 SF805095 PE1 15 SF805096 PE2 16 SF805097 380, 460, 575 with Terminal Block (Standard) Control Fan Electrical 12 SF805090 Power PE1 14 SF805092 380, 460, 575 with Non-Fused Disconnect Option Control Fan Electrical 12 SF805090 Power PE1 14 SF805092 Power-L 13 SF805095 250-300 208/230 Control Fan Electrical 12 SF805090 Power Power-L 13 SF805095 PE1 15 SF805096 PE2 16 SF805097 380, 460, 575 Control Fan Electrical 12 SF805090 Power PE1 14 SF805092 PE2 17 SF805093 FIELD WIRING 30RB Unit Size Voltage Power/Control Figure Number Label Diagram 060-300 All Connections 18 Schematic 19 00DCN5001300A AQUASNAP® 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK™ Controls 60 Hz

Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

Embed Size (px)

Citation preview

Page 1: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-56300002-01 Printed in U.S.A. Form 30RB-3W Pg 1 12-08 Replaces: New

Wiring DiagramsUNITS WITH STARTING SERIAL NUMBER 3507Q

INDEX*

* See Table 1 for modular sizes.

POWER SCHEMATICS30RB Unit Size Voltage Figure Number Label Diagram

060-100 All 1 00PSN500030200A110-190 All 2 00PSN500187100A210-300 All 3 00PSN500187000A

CONTROL SCHEMATICS30RB Unit Size Voltage Figure Number Label Diagram

060-080 All4 00PSN500029500A5 00PSN500029600A

090, 100 All6 00PSN500190800A5 00PSN500029600A

110-150 All6 00PSN500190800A7 00PSN500029700A

160-190 All8 00PSN500190900A7 00PSN500029700A

210-300 All 900PSN500191000A00PSN500029800A

COMPONENT ARRANGEMENTS30RB Unit Size Voltage Connections Control Box Type Figure Number Label Diagram

060,070208/230 Control/Power Combination 10 SF805094

380, 460, 575 Control/Power Combination 11 SF805091

080-120208/230

Control Fan Electrical 12 SF805090Power Power-L 13 SF805095

380, 460, 575 Control/Power Combination 11 SF805091

130-190

208/230Control Fan Electrical 12 SF805090

PowerPower-L 13 SF805095

PE1 15 SF805096380, 460, 575

with Terminal Block (Standard)Control Fan Electrical 12 SF805090Power PE1 14 SF805092

380, 460, 575with Non-Fused

Disconnect Option

Control Fan Electrical 12 SF805090

PowerPE1 14 SF805092

Power-L 13 SF805095

210, 225

208/230

Control Fan Electrical 12 SF805090

PowerPower-L 13 SF805095

PE1 15 SF805096PE2 16 SF805097

380, 460, 575with Terminal Block (Standard)

Control Fan Electrical 12 SF805090Power PE1 14 SF805092

380, 460, 575with Non-Fused

Disconnect Option

Control Fan Electrical 12 SF805090

PowerPE1 14 SF805092

Power-L 13 SF805095

250-300

208/230

Control Fan Electrical 12 SF805090

PowerPower-L 13 SF805095

PE1 15 SF805096PE2 16 SF805097

380, 460, 575Control Fan Electrical 12 SF805090

PowerPE1 14 SF805092PE2 17 SF805093

FIELD WIRING30RB Unit Size Voltage Power/Control Figure Number Label Diagram

060-300 AllConnections 18 —Schematic 19 00DCN5001300A

AQUASNAP®30RB060-390

Air-Cooled Liquid Chillers with COMFORTLINK™ Controls60 Hz

Page 2: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

2

NOTE: For operating sequence, refer to the Controls, Start-Up,Operation, Service, and Troubleshooting literature.

SAFETY CONSIDERATIONS

Installing, starting up, and servicing this equipment can behazardous due to system pressures, electrical components, andequipment location (roof, elevated structures, etc.). Onlytrained, qualified installers and service technicians shouldinstall, start up, and service this equipment. When working onthis equipment, observe precautions in the literature, and ontags, stickers, and labels attached to the equipment, and anyother safety precautions that apply. Follow all safety codes.Wear safety glasses and work gloves. Use care in handling,rigging and setting this equipment, and in handling all electri-cal components.

GENERALThis publication contains Wiring Diagram information for

the 30RB060-390 air-cooled liquid chillers with electroniccontrols. These chillers are equipped with ComfortLink™ con-trols and electronic expansion valves.NOTE: Unit sizes 315-390 are modular units that are shippedin separate sections as modules A or B as noted in position 8 ofthe unit model nomenclature. See Table 1 for a listing of unitsizes and modular combinations.NOTE: The nameplate for modular units contains only the firsttwo digits in the model number. For example, 315A and 315Bname plates read 31A and 31B.

Table 1 — Modular Unit Combinations

NOTE: An “A” in the fifth position of the model number indicates thedesign series.

WARNING

Electrical shock can cause personal injury and death. Shutoff all power to this equipment during installation andservice. There may be more than one disconnect switch.Tag all disconnect locations to alert others not to restorepower until work is completed.

MODULAR UNITS MODULE A MODULE B30RBA315 30RBA160 30RBA16030RBA330 30RBA170 30RBA16030RBA345 30RBA170 30RBA17030RBA360 30RBA190 30RBA17030RBA390 30RBA190 30RBA190

Page 3: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

3

LEGEND

NOTES1. Factory wiring is in accordance with Underwriters Laboratories (UL) 1995 standards. Field modifications or additions must be

in compliance with all applicable codes.2. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.

Incoming wire size range for the terminal block is no. 4 American Wire Gage (AWG) to 500 kcmil.Incoming wire size range of non-fused disconnect with Minimum Circuit Amps (MCA) up to 599.9 amps is 3/0 to 500 kcmil.Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is 1/0 to 500 kcmil.Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is 250 to 500 kcmil.

3. Terminals 9 and 10 of TB5 are for field external connections for remote on-off. The contacts must be rated for dry circuit appli-cation capable of handling a 24 vac load up to 50 mA.

4. Terminals 1 and 2 of TB5 are for external connections of chilled water pump interlock. The contacts must be rated for dry cir-cuit application capable of handling a 24 vac load up to 50 mA.

5. Terminals 11 and 13 of TB5 are for control of chilled water pump 1 (PMP1) starter.Terminals 13 and 15 of TB5 are for control of chilled water pump 2 (PMP2) starter.The maximum load allowed for the chilled water pump relay is a 5 va sealed, 10 va inrush at 24 v. Field power supply is notrequired.

6. For control of chilled water pumps, a set of normally open contacts rated for dry circuit application must be supplied from fieldsupplied pump starter relay. Connect contacts to violet and pink wires in harness from main base board channel 18. Wires inharness are marked PMP1-13 and PMP1-14.

7. Terminals 12 and 13 of TB5 are for an alarm relay. The maximum load allowed for the alarm relay is 10 va sealed, 24 va inrushat 24 v. Field power supply is not required.

8. Make appropriate connections to TB6 as shown for energy management board options. The contacts for occupancy override,demand limit and ice done options must be rated for dry circuit application capable of handling a 24 vac load up to 50 mA.

ALM R — Alarm RelayALT R — Alert RelayC — Contactor, CompressorCB — Circuit Breaker/DisconnectCCH — Compressor Crankcase HeaterCL-HT — Cooler HeaterCOMP — CompressorCWFS — Chilled Water Flow SwitchCWP — Chilled Water PumpDLSV — Discharge Line Solenoid ValveDPT — Discharge Pressure TransducerEQUIP — EquipmentEXV — Electronic Expansion ValveEMM — Energy Management ModuleFB — Fan BoardFC — Fan ContactorFIOP — Factory-Installed OptionFM — Fan MotorFN — FanFU — FuseGFI-CO — Ground Fault Interrupter — Convenience OutletGND — GroundHOA — Hand/Off/AutoHOA-A — Hand/Off/Auto, Auto SettingHOA-H — Hand/Off/Auto, Hand SettingHPS — High-Pressure SwitchLWT — Leaving Water TemperatureMBB — Main Base BoardMLV — Minimum Load ValveMM — Low Ambient Temperature Head Pressure ControlMTR — MotorNEC — National Electrical Code (U.S.A.)OAT — Outdoor Air Temperature

PMP — Pump, Chilled WaterPMPI — Chilled Water Pump InterlockRDY R — Ready RelayRRB — Reverse Rotation BoardRRC — Reverse Rotation ContactRRT — Reverse Rotation TimerRUN R — Run RelaySGT — Suction Gas ThermistorSHD R — Shutdown RelaySPM — Scroll Protection ModuleSPT — Suction Pressure TransducerSW — SwitchT — ThermistorTB — Terminal BlockTEMP — TemperatureTRAN — Transformer

Terminal Block Connection

Marked Terminal

Unmarked Terminal

Unmarked Splice

Factory Wiring

Optional Wiring

Indicates common potential.Does not represent wiring.

FIOP or Accessory

Wire Tag

Page 4: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

4

COOLER HEATER OPTION

PUMP OPTION

*

* Units with dual point power option have 2 reverse rotation boards.

Fig. 1 — Power Schematic, 30RB060-100 (All Voltages)

a30-4560

Page 5: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

5

Fig. 2 — Power Schematic, 30RB110-190 (All Voltages)a30-4654

Page 6: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

6

Fig. 3 — Power Schematic, 30RB210-300 (All Voltages)a30-4655

* For 380, 460, and 575-v units in sizes 250-300 there are 2 RRBs: one in the Fan Electrical Box and one in PE2. For208/230-v units in sizes 210-300, there are 3 RRBs: one inthe Fan Electrical Box, one in PE1 and one in PE2.

*

Page 7: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

7

COMPRESSOR ANDFAN LOCATIONS

*Field-Supplied.

*

*

Fig. 4 — Control Schematic, 30RB060-080 (All Voltages)

a30-4563

Page 8: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

8

SEE FIG. 8 FOR MOREHOA WIRING DETAILS

* HPS is located on last compressor in circuit for each unit.

*

*

Fig. 5 — Control Schematic, 30RB060-100 (All Voltages)

a30-4564

Page 9: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

9

Fig. 6 — Control Schematic, 30RB090-150 (All Voltages)a30-4656

Page 10: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

10

Fig. 7 — Control Schematic, 30RB110-190 (All Voltages)

* HPS is located on last compressor in circuit for each unit.

*

*

a30-4566

Page 11: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

11

Fig. 8 — Control Schematic, 30RB160-190 (All Voltages)a30-4657

Page 12: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

12

Fig. 9 — Control Schematic, 30RB210-300 (All Circuits)a30-4658

Page 13: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

13

* HPS is located on last compressor in circuit for each unit.

*

*

*

Fig. 9 — Control Schematic, 30RB210-300 (All Circuits) (cont)

a30-4569

Page 14: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

14

Fig. 10 — Component Arrangement, Combination Box, 30RB060, 070 (208/230 v)

a30-4570

Page 15: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

15

Fig. 11 — Component Arrangement, Combination Box, 30RB060-120 (380, 460 and 575 v)

a30-4571

Page 16: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

16

Fig

. 12

— C

om

po

nen

t A

rran

gem

ent,

Fan

Ele

ctri

cal B

ox

30R

B08

0-12

0 (2

08/2

30 v

); 3

0RB

130-

300

(All

Vo

ltag

es)

a30-4572

Page 17: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

17

STANDARDTERMINALBLOCK

Fig. 13 — Component Arrangement, Power-L Box 30RB080-300 (208/230 v); 130-225 (380, 460 and 575 v with Non-Fused Disconnect Option)

a30-4573

Page 18: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

18

Fig

. 14

— C

om

po

nen

t A

rran

gem

ent,

Po

wer

Ele

ctri

cal B

ox

1, 3

0RB

130-

300

(380

, 460

, an

d 5

75 v

wit

h T

erm

inal

Blo

ck o

r N

on

-Fu

sed

Dis

con

nec

t O

pti

on

)

a30-4574

Page 19: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

19

ST

AN

DA

RD

TE

RM

INA

LB

LOC

K

Fig

. 15

— C

om

po

nen

t A

rran

gem

ent,

Po

wer

Ele

ctri

cal B

ox

1, 3

0RB

130-

300

(208

/230

v)

a30-4575

Page 20: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

20

Fig

. 16

— C

om

po

nen

t A

rran

gem

ent,

Po

wer

Ele

ctri

cal B

ox

2, 3

0RB

210-

300

(208

/230

v)

a30-4576

Page 21: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

21

Fig

. 17

— C

om

po

nen

t A

rran

gem

ent,

Po

wer

Ele

ctri

cal B

ox

2, 3

0RB

250-

300

(380

, 460

an

d 5

75 v

)

a30-4577

Page 22: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

22

POWER

ELECTRICAL

2

POWER

ELECTRICAL

1

FANELECTRICAL

DISPLAYLOCATION

SIZE 080-120,208/230 VSIZE 130-300,ALL VOLTAGESFIELD CONTROLWIRING ENTRY

SIZE 060, 070ALL VOLTAGESSIZE 080-120380, 460, 575 VFIELD CONTROLWIRING ENTRY

DISPLAYLOCATION

MAIN POWER ENTRANCE

CO

MB

INA

TIO

N

OR

PO

WE

R-L

MAIN POWER ENTRANCE

TYPICAL CONTROL BOX LOCATIONSAND MAIN POWER ENTRY

MAIN POWER ENTRANCE

Fig. 18 — Field Wiring Connections – All 30RB Units (See Table 2)

Page 23: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

23

Table 2 – Field Wiring Connections and Control Boxes

30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER

ENTRANCE CONTROL BOX

060,070 208/230, 380, 380, 460, 575

Standard (Terminal Block)Single Point Circuit 1 Combination

Dual PointCircuit 1 CombinationCircuit 2 Combination

Non-Fused Disconnect Option* Single Point Circuit 1 Combination

080-120

208/230Standard (Terminal Block)

Single Point Circuit 1 Power-L

Dual PointCircuit 1 Power-LCircuit 2 Power-L

Non-Fused Disconnect Option* Single Point Circuit 1 Power-L

380, 460, 575Standard (Terminal Block)

Single Point Circuit 1 Combination

Dual PointCircuit 1 CombinationCircuit 2 Combination

Non-Fused Disconnect Option* Single Point Circuit 1 Combination

130-190

208/230

Standard (Terminal Block)Single Point Circuit 1 Power-L

Dual PointCircuit 1 Power-LCircuit 2 PE1

Non-Fused Disconnect OptionSingle Point Circuit 1 Power-L

Dual PointCircuit 1 Power-LCircuit 2 PE1

380, 460, 575

Standard (Terminal Block)Single Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 PE1

Non-Fused Disconnect OptionSingle Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 Power-L

210, 225

208/230†Standard (Terminal Block) Dual Point

Circuit 1 Power-LCircuit 2 PE2

Non-Fused Disconnect Option Dual PointCircuit 1 Power-LCircuit 2 PE2

380, 460, 575

Standard (Terminal Block)Single Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 PE1

Non-Fused Disconnect OptionSingle Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 Power-L

250-300

208/230†Standard (Terminal Block) Dual Point

Circuit 1 Power-LCircuit 2 PE2

Non-Fused Disconnect Option Dual PointCircuit 1 Power-LCircuit 2 PE2

380, 460, 575

Standard (Terminal Block)Single Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 PE2

Non-Fused DisconnectSingle Point Circuit 1 PE1

Dual PointCircuit 1 PE1Circuit 2 PE2

*Dual point connection is not available when non-fused disconnect option is selected.†Single point connection not available.

Page 24: Wiring Diagrams Table 2 – Field Wiring Connections and Control Boxes 30RB UNIT SIZE VOLTAGE ELECTRICAL OPTION CONNECTIONS MAIN POWER ENTRANCE CONTROL BOX 060,070 208/230, 380, 380,

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-56300002-01 Printed in U.S.A. Form 30RB-3W Pg 24 12-08 Replaces: New

Copyright 2008 Carrier Corporation

Fig

. 19

— F

ield

Wir

ing

Sch

emat

ic, A

ll 30

RB

Un

its

*

*

*Fie

ld-s

uppl

ied.

a30-4559

*Fie

ld-s

uppl

ied.