6
Wiring Duct Product Selection Guide

Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

Wiring Duct Product Selection Guide

Page 2: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

2

Comprehensive Wiring Duct SolutionsPVC Flush Cover Wiring DuctStandard 2m lengths, sold base and cover together.

Type DRD, DIN Rail Wiring Duct*Standard 1.8m lengths, sold base and cover together.

Type CWD, Corner Wiring DuctStandard 1.8m lengths. Uses

standard covers sold separately**

Shielded Wiring DuctUses standard covers sold separately**

EMI Noise Shield

PanelMax™ Space Optimization and Noise Mitigation Products

Type NNC, Wide Fingers, Wide Slots Type TNC, Wide Fingers, Wide Slots

Halogen-Free Wiring DuctStandard 2m lengths, sold base and cover together.

Low-Smoke, Halogen-Free Wiring DuctStandard 2m lengths, sold base and cover together.

Type ENC, Narrow Slots, Narrow Fingers Type EWC, Wide Slots, Wide Fingers

* DIN Rail not included.**Use cover part #: C2LG6

Page 3: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

3

Duct Size W x H(mm)

IGInternational Gray – RAL7030

LGLight Gray

WHWhite

12 x 12 FL

25 x 25 ENC EWC NNC FL NNC

25 x 37 NNC TNC NNC

25 x 40 ENC EWC

25 x 50 NNC NNC

25 x 60 ENC EWC

25 x 75 NNC TNC NNC

25 x 80 ENC EWC

37 x 37 NNC TNC NNC

37 x 50 NNC NNC

37 x 75 NNC TNC NNC

40 x 25 ENC EWC

40 x 40 ENC EWC

40 x 60 ENC EWC

40 x 80 ENC EWC

40 x 100 ENC EWC

50 x 50 NNC FL TNC NNC

50 x 75 NNC NNC

50 x 100 NNC NNC

60 x 40 ENC EWC

60 x 60 ENC EWC

60 x 80 ENC EWC

60 x 100 ENC EWC

75 x 75 NNC TNC NNC

80 x 40 ENC EWC

80 x 60 ENC EWC

80 x 80 ENC EWC

80 x 100 ENC EWC

100 x 40 ENC EWC

100 x 50 NNC TNC NNC

100 x 60 ENC EWC

100 x 75 NNC TNC NNC

100 x 80 ENC EWC

100 x 100 ENC EWC NNC NNC

120 x 40 ENC EWC

120 x 60 ENC EWC

120 x 80 ENC EWC

85.0 x 64.4* CWD CWD CWD

111.8 x 90.7* CWD CWD CWD

135.3 x 115.7* CWD CWD CWD

156.7 x 54.0** DRD DRD DRD

184.1 x 79.4** DRD DRD DRD

209.5 x 104.8** DRD DRD DRD

Wiring Duct Available Colors and Sizes

*Corner Duct Profile**DIN Rail Duct Profile

Page 4: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

4

Panduct® PanelMax™ Shielded Wiring DuctShielded wiring duct is a standard PVC wiring duct with bridges between fingers and wrapped with an aluminum foil shield. Sold in 1.8m (6 ft.) lengths, available in three (3) sizes and uses standard covers.

Part NumberSize (W x H)

mm (In.)

G2X2LG6EMI 50 x 50 (2" x 2")

G2X3LG6EMI 50 x 75 (2" x 3")

G2X4LG6EMI 50 x 100 (2" x 4")

Panduct® PanelMax™ Noise ShieldNoise shield is zinc-plated steel and black powder coated except at bonding locations. Each kit contains two (2) 0.9m (3 ft.) sections and four (4) bonding clips.

Part NumberSize (H)mm (In.)

SD2EMI 50 (2")

SD3EMI 75 (3")

SD4EMI 100 (4")

Part Numbering System for Panduct® PanelMax™ DIN Rail Wiring Duct22 IGSizeType Color Length

DRD = DIN Rail Duct Capability Height 22 = 2"(50mm) Height33 = 3" (80mm)Height 44 = 4" (100mm)

IG = International Gray – RAL7030 LG = Light GrayWH = White

6 ft. (1.8m)

DRD 6

Part Numbering System for Panduct® Wiring Duct—

Type

ENC

ENC = Narrow Slot EWC = Wide SlotNNC = Halogen-Free, Metric TNC = Low Smoke Halogen-FreeFL = Flexible Duct

Length2m

2Nominal Widthmm

25ColorIG = International Gray – RAL7030LG = Light GrayWH = White

IGNominal Height

25

mm

X

Part Numbering System for Panduct® PanelMax™ Corner Wiring DuctCWD 2 IG

SizeType Color LengthCWD = Corner Wiring Duct Capability Height

2 = 2" (50mm) Height3 = 3" (80mm) Height4 = 4" (100mm) Height

IG = International Gray – RAL7030 LG = Light GrayWH = White

6 ft. (1.8m)

6

Page 5: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

Wiring Duct Material PropertiesRigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications. It has a UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 50°C (122°F). Used in the manufacture of the following types of Panduit wiring duct and covers: ENC, EWC, CWD, and DRD.

Modified Polyphenylene Oxide (mPPO) – Halogen FreeA special purpose material for use in halogen-free or high-temperature applications. It has a UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95°C (203°F) and is 20% lighter than PVC. Used in the manufacture of the following type of Panduit wiring duct and covers: NNC.

Polyphenylene Ether + High Impact Polystyrene (PPE+HIPS) A special purpose material for use in low-smoke, halogen-free, and high-temperature applications. It has a UL 94 flame class ofV-0 with a UL recognized continuous-use temperature up to 105°C (221°F). Meets the regulatory requirements of the mass transitindustry and other applications where fire and public safety are critical; such as in trains, buses, offshore oil and gas platforms, and other similar environments. Used in the manufacture of Type TNC wiring duct and covers.

Polypropylene (PP)A flexible material with a UL 94 flame class of V-2 with a UL recognized continuous-use temperature up to 65°C (149°F). Used in the manufacture of Type FL flexible wiring duct.

Recommended Precaution when using Type NE, NS, NNC, and TNC Wiring DuctCleaning solvents and cutting fluids that contain any of the following chemical agents should not come into contact with these types of wiring duct or covers. These chemicals are the most commonly known to cause stress cracking.

•Hydrocarbons

• Phenols

• Ketones

• Amines

• Ethers

•Organic,inorganic,andoxidizingacids

• Petrol

Refer to www.panduit.com for more information on chemical resistance.

Wiring Duct Cutting and Installation Tools

Adhesive Tape – Available in various sizes

Type FL – FlexibleWiringDuct;3sizes,

500mm lengths

Nylon Rivets:NR1-C – 100 pcs.

NR1-M – 1000 pcs.

DFCT – Duct Finger Cutting Tool

PBDCT – Bench Mount Duct Cutting Tool

DNT-100 – Duct Notching Tool

TNR – Nylon Rivet Installation Tool

DCT – Hand-Held Duct Cutting Tool

5

Page 6: Wiring Duct Product Selection Guide · 2014. 8. 19. · Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications

Agency Mark Agency Requirement Classification/Performance

Wiring Duct Types/Products

Underwriters Laboratories, Inc. File No. E147128

UL 1565 Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F)

All wiring duct types and covers

UL 1565 CSA C22.2 No. 18.5-03

Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F) Type DRD

Underwriters Laboratories, Inc.

UL 508 section 15

An insulating barrier material shall comply with the minimum material properties indicated in Table 15.1 PVC divider walls

UL 508 sections 34

and 181

Qualifies as a metal barrier with required thickness as indicated in Table 6.1 SD*EMI metal

barrier

Canadian Standards Association

File No. 016446

CSA C22.2 No. 18.5-02

Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F) All wiring duct

types and covers

Conformity European

Low Voltage Directive

2006/95/EC

• CDS(cableductingsystemforimpact2J)• Minimumstorage,transport,installation,andapplication temperature: -5°C (23°F)• Maximumapplicationtemperature:60°C(140°F)• Non-flamepropagating• Withoutelectricalcontinuity• Coverremovablewithoutatool

ENC, EWC, NNC, and TNC

EN 50085-1 EN 50085-2-3

DIN German Institute for

Standardization

DIN 43659

• Specifiesdimensionsforslottedtrunkingsusedinelectrical switch-gear assemblies and that conform to DIN VDE 060 Part 506 •Channelmountingholepattern,slotdimensions,pitch,andlocation •Distancefromfirsttolastlike-sizemountinghole •Minimumoverallproductlength

ENC, EWC, NNC, and TNC

DIN 5510-2 DIN 54837

Burning Class: S4 Smoke Class: SR2 Dripping Class: ST2

TNC

AFNOR French Association of Normalization

NF F 16-101 NF F 16-102

Type NNC Wiring Duct Classification = F3/I4 Type TNC Wiring Duct Classification = F1/I4 NNC and TNC

UNIFER Italian Railway Standards EN ISO 11925-2

Pass30-secondflameapplicationTNC

FRA – Federal Railroad

Administration49 CFR Part 238

Surface Flammability: < 35 Smoke Density Ds (1.5) < 100Ds (4.0) < 200

TNCNFPA – National Fire Protection

AssociationNFPA130

National FireProtection Agency

NFPA 79-2012,Section 13.3.1 IEC 60332-1

Non-metallic duct shall be permitted (inside enclosures) only when theyaremadewithaflame-retardantmaterial;flame-retardantmaterial is defined in the standard by the IEC 60332-1 test method

All wiring duct types and covers

(except FL)

NFPA 79-2012,Section 13.5.2

Panduit publishes a maximum percentage wire fill for common wire types equal to 50% of the interior cross-sectional area of the wiring duct

All wiring duct types and covers

NFPA 79-2012,section 13.1.6.9

Panduit bend radius control accessories can be mounted at right angles and T junctions created using wiring duct in order to maintain cable bend radius control

Corner strip with 1" bend radius

control

European UnionEuropean Directive

2002/95/EC

Meets the requirements on the Restriction of Hazardous Substances and is free of the six substances listed in the directive All wiring duct

products

Panduit Wiring Duct Approvals and Compliances

©2014 Panduit Corp. ALL RIGHTS RESERVED.

WDSG01--SA-UKE6/2014

Contact Customer Service by email: [email protected] by phone: 800.777.3300

Visit us at www.panduit.comFor more information