Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Wires & Cables
Area No. ofCores
Thicknessof
Insulation(Nom.)
Sq.mm Nos mm
Part Number
Product Construction Technical Data
Siechem Multicore Stranded Copper Conductor PVC Insulated Extruded or Wrapped Inner Sheathed Armoured and Flat Strip
Armoured PVC Overall Sheathed Cable Conforming to IS : 1554 (Part 1) - 1988.
Application
Features
ü�Transmission and distribution of Power Industrial unitsü�Commercial and residential placesü Indoor and outdoor usesü�Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables.
www.siechem.com
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
4
Nominaldimensions of Armour Strip
Minimumthickness of Outer Sheath
Approx.OverallDia. of Cable
Approx. Weightof Cable
Flat Strip Armoured
Kg/km Amps Amps Mtrs.
Current Rating
In Air
In Ground
Thicknessof
Innersheath(Nom.)
mm mm mm mm
10
12
14
16
19
21
24
27
30
33
37
44
52
61
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
18.5
19.0
19.5
20.5
21.5
22.5
25.0
25.5
26.5
27.5
28.5
32.0
33.5
35.5
680
730
810
880
990
1050
1190
1290
1370
1500
1600
1900
2140
2370
11
10
10
10
09
09
08
08
08
07
07
06
06
06
13
12
11
11
10
09
09
09
09
08
08
07
07
06
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
Siechem Multicore APC Stranded Conductor GI Strip Armoured Cable
ü�Conductor : Annealed Plain Stranded Copper Conductor Complying with IS 8130-2013ü�Insulation : PVC Type A Conforming to IS 5831-1984 ü�Innersheath : PVC ST1 (Optional - Wrapped with Tape)ü�Armour : GI Stripü�Jacket : PVC ST1 Conforming to IS 5831-1984 (Optional - FR & FRLS)
0ü�Operating Temperature : +70 C
0 Optional : 85 C 0
ü�Short Circuit Temperature : 160 Cü�Bending Radius (min) : 12 x Cable diaü�Rated Voltage : 1100 Vü�Test Voltage : 3 kV for 5 mins.ü�Specification : IS 1554
149EF1310
149EF1312
149EF1314
149EF1316
149EF1319
149EF1321
149EF1324
149EF1327
149EF1330
149EF1333
149EF1337
149EF1344
149EF1352
149EF1361
Catalogue No
149EF
IS 1554 Pt.1
CM/L-6799006
OHSAS 18001
ISO 9001
ISO/TS 16949
OHSAS 18001
ISO 14001
ISO/TS 16949
ISO 9001
ü�Enhanced mechanical, electrical, thermal and weathering properties.ü�Soldering iron resistantü�Resistance to corona effect.ü�Easy jointing & terminationü�Better resistance to most chemicals & acidsü�Low direct electric losses.ü�High current carrying capacity.�
Standard Length