108
Wires & Cables Product Catalogue ޘອഺ ޘອഺ

Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

Wires & Cables Product Catalogue

Page 2: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

LTK – We are a leading global manufacturer of an extensive range of wire & cable products for a wide spectrum of OEM applications. - Appliance Wiring Material (AWM) Cables - Halogen-Free Cables - Smartphone, Multimedia Applications Cables - Communications Equipment - Automotive Equipment Founded in 1981, LTK is the first cable manufacturer in the world to beawarded UL RoHS Green Mark. Our manufacturing and sales network inAsia enable us to be close to our customers and provide high levels ofservice.

About LTK

www.ltkcable.com

Page 3: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

Manufacturing Plants

www.ltkcable.com

Page 4: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

UL, CUL

Certification Body : Underwriters Laboratories (UL)

E148000

E154336

E164618

E166193

E222393

E314271

E363614

Appliance Wiring Material

Communications Cable

Power Limited Circuit Cable

Flexible Cords

Plastics

Optical Fiber Cable

Photovoltaic Wire

AVLV2, AVLV8

DUZX, DUZX7

QPTZ

ZJCZ, ZJCZ7

QMFZ2, QMFZ8

QAYK, QAYK7

ZKLA

889 Styles

CMX, CM, CMG, CMR, CMH

CL2X, CL2, CL2R,CL3X, CL3, CL3R,

PLTC (sun res)

SPE-1, SPE-2, SPT-1, SPT-2,SPT-3, NISPE-1, NISPE-2,

NISPT-1, NISPT-2,SVE, SJE, SE, SVT, SJT, ST

UL94, V-0, V-2

OFN, OFNH

PV Wire

File No. UL Listed, Recognized

or Verified Products

UL

UL & cUL

Category No.Product Types

CCC-China Compulsory Certification

Certification Body : China Certification Centre

Products : PVC Insulated Wires & Cables

60227 IEC 01 (BV)60227 IEC 02 (RV)60227 IEC 05 (BV)60227 IEC 06 (RV)

60227 IEC 07 (BV-90)60227 IEC 08 (RV-90)60227 IEC 52 (RVV)60227 IEC 53 (RVV)AV, AV-90, AVVR,

BV, BVR,JB8734.2-2012 (BVR)JB8734.3-2012 (RVS)

RVS, RVV, RVVP, RVVP1

200201010500662320020101050104862002010105017736200201010500662520020101050177372006010105205819200801010528579520020101050066222002010105017738200201010501773920080101052857972005010105159624200701010524062320020101050104872004010105124312

Registration No. Product Types

www.ltkcable.com

Product Certification

Page 5: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Z-Mark

Certification Body : Japan Electrical Safety & Environment Technology Laboratories (JET)

Products : Cable Insulation

201AC0534201AC0534-001

Certification No.

F-Mark

Certification Body :Japan Quality Assurance Organization (JQA)

Products :General Wires & Cables

F-HCLF-LTD

Registration No.

<PS>E Mark

Certification Body : Japan Electrical Safety & Environment Technology Laboratories (JET)

Products : PVC Insulated Flexible Cords, Halogen-Free Power Cords F307

F706

VSFHVSFHVFF

HVCTFOSF/FOFF/F

OOCTFK/FEMCSF

Registration No. Product Types

Page 6: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Contents

Page 7: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 8: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 9: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 10: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 11: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 12: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

1 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

28262422201816141210876542

7/0.1277/0.1611/0.1617/0.1626/0.1616/0.25426/0.25441/0.25465/0.25466/0.32

169/0.2547/29/0.2547/38/0.2547/30/0.3219/37/0.2019/35/0.254

0.380.480.610.760.941.161.491.872.363.004.204.725.406.057.008.65

0.790.820.790.820.790.800.790.790.790.791.201.151.521.521.531.53

1.952.122.192.402.522.763.083.463.944.566.607.158.909.4010.212.0

23915094.259.436.723.214.68.965.643.552.231.771.401.110.880.55

- Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL11028 & UL3386 : UL11028 UL3386

E148000 AWM STYLE 1015 AWG NO. 105C 600V VW-1 --- c AWM I A/B 105C 600V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-3/0 AWG, Lead free PVC insulation 30-3/0 AWG

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.410.410.410.410.410.410.410.41

1.121.201.301.431.581.762.002.32

38123915094.259.436.723.214.6

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL10982 & UL3385 : UL10982 UL3385

E148000 AWM STYLE 1007 AWG NO. 80C 300V VW-1 --- c AWM I A/B 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-16 AWG, Lead free PVC insulation 32-16 AWG

Page 13: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

2www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

28262422201816

7/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.380.480.610.760.941.181.49

0.450.450.460.460.460.460.46

2.342.442.582.742.923.163.48

23915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

38/0.145/0.146/0.154/0.156/0.164/0.174/0.1

1.441.541.671.822.002.242.56

No./mm/

Diameter (mm)

Spiral Shield

0.430.430.430.430.430.430.43

1.241.341.471.621.802.042.36

Thickness Diameter (mm)

Insulation

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL10800 & UL10983 : UL10800 UL10983

E148000 AWM STYLE 1185 AWG NO. 80C 300V VW-1 --- c AWM I A/B 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-4/0 AWG, Tinned or bare copper wire spiral shield, Lead free PVC insulation

30-4/0 AWG

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

3028262422201816

7/0.107/0.1277/0.1611/0.617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.260.260.260.270.260.260.260.26

0.820.901.001.151.281.461.702.02

38123915094.259.436.723.214.6

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL10368 & UL10981 : UL10368 UL10981

E148000 AWM STYLE 1061 AWG NO. 80C 300V VW-1 --- c AWM I A/B 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-10 AWG, Lead free SR-PVC insulation 30-10 AWG

Page 14: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

3 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

262422201814

1/0.411/0.5111/0.6437/0.3241/0.1641/0.254

0.410.510.640.961.181.87

0.510.550.550.550.560.57

1.501.701.702.052.303.00

14389.256.436.723.28.96

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 200°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 1330 AWG NO. 200C 600V VW-1 --- c AWM I A/B 200C 600V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-4/0 AWG, FEP insulation 30-4/0 AWG

20181612

1/0.8131/1.02

26/0.25465/0.254

0.811.021.492.36

0.150.150.150.13

1.902.152.603.50

35.222.214.65.64

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.390.420.410.38

1.601.852.303.20

Thickness (mm)

Diameter (mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 1316 AWG NO. 105C 600V H --- c AWM I A 105C 600V FT2 -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 26-12 AWG, Lead free PVC insulation, Nylon jacket 26-12 AWG

Page 15: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

4www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2220181614

7/0.25426/0.161/1.0265/0.1649/0.25

0.760.941.021.492.02

0.150.130.150.150.14

1.902.052.152.603.45

59.436.723.214.68.96

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.420.380.410.410.57

1.601.751.852.303.16

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 90°C

- Rated voltage : 1000V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 1452 AWG NO. 90C 1000V H --- c AWM I A 90C 1000V FT2 -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 26-12 AWG,Lead free PVC insulation, Nylon jacket

26-12 AWG

28262422201816

7/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.380.480.610.760.941.181.49

0.410.410.410.410.410.610.61

1.201.301.431.581.762.402.70

23915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL3385 & UL11027 : UL3385 UL11027

E148000 AWM STYLE 1430 AWG NO. 105C 300V VW-1 --- c AWM I A/B 105C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-16 AWG, Crosslinked lead free PVC insulation 30-16 AWG

Page 16: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

5 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

30282624222018161412

7/0.107/0.1277/0.1611/0.1617/0.167/0.3241/0.1626/0.25441/0.25465/0.254

0.300.380.480.610.760.961.181.491.872.36

0.450.410.410.410.410.410.410.410.410.47

1.201.201.301.431.581.782.002.322.703.30

38123915094.259.436.723.214.68.965.64

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 80°C or 90°C or 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL3385 : UL3385

E148000 AWM STYLE 1569 AWG NO. 105C 300V VW-1 --- c AWM I A/B 105C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-2 AWG, Lead free PVC insulation 30-2 AWG

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.350.350.350.350.350.350.350.35

1.721.801.902.032.182.362.602.92

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

25/0.129/0.130/0.136/0.140/0.146/0.153/0.163/0.1

1.021.101.201.331.481.661.902.22

No./mm/

Diameter (mm)

Spiral Shield

0.260.260.260.260.260.260.260.26

0.820.901.001.131.281.461.702.02

Thickness Diameter (mm)

Insulation

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL10800 & UL10983 : UL10800 UL10983

E148000 AWM STYLE 1533 AWG NO. 80C VW-1 --- c AWM I A/B 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-16 AWG, Lead free SR-PVC insulation,Tinned or bare copper wire, spiral shield, Lead free PVC jacket

30-16 AWG

Page 17: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

6www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

262422201816

7/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.480.610.760.941.181.49

0.250.490.460.570.370.40

1.802.402.502.903.203.10

15094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)

Secondary Layer

Thickness

(mm)

0.400.410.410.410.640.41

Primary Layer

Thickness

(mm)

Diameter (mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL10937 & UL11045 : UL10937 UL11045

E148000 AWM STYLE 1672 AWG NO. 105C 300V VW-1 --- c AWM I A/B 105C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, Lead free PVC insulation

3634323030282826242222201816

7/0.0507/0.0657/0.087/0.107/0.107/0.1277/0.1277/0.167/0.2

7/0.167/0.1626/0.1665/0.12754/0.18

0.150.1950.240.300.300.380.380.480.600.760.760.941.181.52

---

0.35-

0.35---

0.58-

0.560.590.61

---

1.80-

1.80---

2.80-

3.103.203.60

155297860138138123923915094.259.459.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

---

28/0.1-

28/0.1---

37/0.12-

57/0.147/0.1254/0.12

---

1.10-

1.10---

1.64-

2.002.022.39

No./mm/

Diameter (mm)

Spiral Shield

0.150.150.230.300.200.260.260.260.250.320.250.430.300.32

0.450.500.700.900.700.900.901.001.101.401.251.801.782.15

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL1640 & UL10983 : UL1640 UL10983

E148000 AWM STYLE 1571 AWG NO. 80C 30V VW-1 --- c AWM I A/B 80C 30V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded, Top coated, Over coated copper wire or solid copper conductor, 50 AWG minimum,Lead free PVC or SR-PVC insulation

50 AWG

Page 18: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

7 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.280.280.280.280.280.280.350.35

0.860.941.041.171.321.501.882.19

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 150°C or 200°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10086 AWG NO. 200C 600V VW-1 --- c AWM I A/B 200C 600V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded silver conductor, ETFE insulation

40363432302826

7/0.037/0.057/0.067/0.087/0.107/0.1277/0.16

0.090.150.180.240.300.380.48

0.070.060.070.070.070.100.10

0.250.270.320.380.540.600.70

500015521050601381239150

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10064 AWG NO. 105C 30V VW-1 --- c AWM I A 105C 30V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned copper or tinned copper alloy conductor, 40 AWG minimum, FEP insulation 40 AWG

Page 19: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

8www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

32282624

7/0.087/0.1277/0.167/0.20

0.240.380.480.60

0.150.180.200.20

0.650.750.881.00

60123915094.2

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 80°C

- Rated voltage : 150V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10272 AWG NO. 80C 150V VW-1 --- c AWM I A 80C 150V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 36-20 AWG, Lead free PVC insulation 36-20 AWG

282422201816

7/0.1277/0.2017/0.1626/0.1616/0.25465/0.16

0.380.610.760.941.181.49

0.540.530.540.530.570.56

1.451.661.832.002.302.60

23994.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10097 AWG NO. 105C 600V VW-1 --- c AWM I A/B 105C 600V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 30-2 AWG, Crosslinked Lead free PVC insulation 30-2 AWG

Page 20: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

9 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

345689

1011121518202425

2828282828262626282428242426

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.207/0.167/0.1277/0.1277/0.207/0.207/0.16

4.004.805.005.005.006.306.606.606.008.007.408.509.508.60

23923923923923915015015023994.223994.294.2150

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

16/4/0.116/4/0.1216/4/0.1216/5/0.1216/7/0.1016/6/0.1224/5/0.1216/8/0.1216/7/0.1224/7/0.1216/7/0.1224/8/0.1224/9/0.1224/8/0.12

No./mm/

Braid Shield

0.260.260.260.260.260.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.000.901.120.901.121.121.00

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21143 : UL21143

E148000 AWM STYLE 2464 AWG NO. 80C 300V VW-1 --- c AWM I/II A/B 80C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, Lead free SR-PVC insulation, Aluminum mylar shield,Tinned or bare copper stranded drain wire, Tinned or bare copper wire braid shield, Lead free PVC jacket

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.260.260.260.260.260.280.350.35

0.820.901.001.131.281.501.882.19

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 200°C

- Rated voltage : 600V

- Reference standard : UL 758, UL 1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10308 AWG NO. 200C 600V VW-1 --- c AWM I A/B 200C 600V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded silver conductor, FEP insulation

Page 21: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

10www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2020

7/0.3226/0.16

0.940.94

0.450.64

3.904.80

36.736.7

Conductor

AWG

23

No.of Cores No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.230.33

1.501.60

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2509 AWG NO. 80C 300V VW-1 --- c AWM I A/B 80C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, Lead free SR-PVC insulation,Lead free PVC jacket

2826242220182826242228262422282624222826242228262422

22222233334444555566667777

7/0.1277/0.167/0.2

7/0.25426/0.1641/0.167/0.1277/0.167/0.2

7/0.2547/0.1277/0.167/0.2

7/0.2547/0.1277/0.167/0.2

7/0.2547/0.1277/0.167/0.2

7/0.2547/0.1277/0.167/0.2

7/0.254

0.380.480.600.760.941.180.380.480.600.760.380.480.600.760.380.480.600.760.380.480.600.760.380.480.600.76

0.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.43

1.24x2.581.34x2.781.45x3.041.62x3.341.80x3.702.04x4.231.24x3.921.34x4.221.45x4.631.62x5.061.24x5.261.34x5.661.45x6.221.62x6.781.24x6.601.34x7.101.45x7.811.62x8.501.24x7.941.34x8.541.45x9.401.62x10.221.24x9.281.34x10.01.45x11.001.62x11.94

23915094.259.436.723.223915094.259.423915094.259.423915094.259.423915094.259.423915094.259.4

Conductor

AWGNo.of Cores No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21311 & UL21458 : UL21311 UL21458

E148000 AWM STYLE 2468 AWG NO. 80C 300V VW-1 --- c AWM I A 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-16 AWG, Lead free PVC insulation 32-16 AWG

Page 22: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

11 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2222222233333333

30282624222018163028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.2547/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

2.642.803.003.263.603.964.445.082.772.942.903.433.764.144.665.35

38123915094.259.436.723.214.638123915094.259.436.723.214.6

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

44/0.1048/0.1053/0.1060/0.1057/0.1263/0.1273/0.1287/0.1252/0.1056/0.1062/0.1061/0.1267/0.1275/0.1293/0.12110/0.12

No./mm/

Spiral Shield

0.260.260.260.260.260.260.260.260.260.260.260.260.260.260.350.35

0.820.901.001.131.281.461.702.020.820.901.001.131.281.461.882.19

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Reference standard : UL758,UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21307 & UL21457 : UL21307 UL21457

E148000 AWM STYLE 2547 AWG NO. 80C VW-1 --- c AWM I/II A/B 80C 300V FT1 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, 30-16 AWG, Lead free SR-PVC insulation,Tinned or bare copper wire spiral shield, Lead free PVC jacket

30-16 AWG

2~502~502~402~302~302~302~202~162~102~72~7

3028262422201816141210

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.25465/0.25466/0.32

38123915094.259.436.723.214.68.965.643.55

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.410.410.410.410.410.410.410.410.510.790.79

1.121.201.301.431.581.762.002.322.903.944.58

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2517 AWG NO. 105C 300V VW-1 --- c AWM I/II A/B 105C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, Lead free PVC insulation,Tinned copper wire braiding shield (option), Lead free PVC jacket

Page 23: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

12www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

15C25P4C9C25P2C3C4C5C6C

15C2C

3C+(1C)

26262424242222222222222016

(24)

7/0.161/0.417/0.207/0.201/0.5117/0.2547/0.2547/0.2547/0.2547/0.2547/0.25426/0.16

105/0.127(19/0.12)

6.5011.64.405.8012.54.204.504.804.935.408.054.60

6.00

15015094.294.294.259.459.459.459.459.459.436.714.6

(94.2)

Conductor

Construction (Cores/Pairs)

AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.801.030.760.760.760.760.870.800.760.760.760.76

0.76

Thickness (mm)

0.250.300.260.230.280.260.260.260.230.230.270.150.23

(0.23)

1.001.001.121.101.101.281.281.281.221.251.301.352.00

(1.10)

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 150V

- Reference standard : UL758,UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2576 AWG NO. 80C 150V VW-1 --- c AWM I/II A/B 80C 150V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, Lead free PVC insulation and jacket

302828262626

222223

7/0.107/0.1277/0.1277/0.167/0.16

10/0.127

0.330.60x0.600.52x0.480.33x0.330.55x0.550.52x0.52

2.353.05x6.103.20x6.402.50x5.003.10x6.202.70x8.10

381239239150150150

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

44/0.1042/0.12

16/4/0.1251/0.10

16/5/0.1034/0.52

No./mm

Braiding/Spiral Shield

0.250.610.610.610.610.42

0.801.601.601.701.701.30

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2552 AWG NO. 60C 30V VW-1 --- c AWM I/II A/B 60C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, 40-10 AWG, PE, FR-PE or PP insulation 2-10 cores (Flat or Round), Tinned or bare copper wire, spiral or braid shield, Lead free PVC jacket

40-10 AWG 2-10

Page 24: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

13 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

420222323472323535252

2824222018181616161614141212121010876

7/0.1277/0.207/0.25426/0.1641/0.1616/0.25465/0.1626/0.25465/0.1630/0.2541/0.25441/0.25465/0.25465/0.25465/0.25466/0.3266/0.32

7/95/0.1277/29/0.2547/38/0.254

3.5012.505.007.507.207.107.808.5011.2010.708.809.20

5.20x8.9010.5013.5012.2015.00

7.80x14.0024.00

12.00x21.00

23794

59.436.723.223.215.114.615.113.78.968.965.645.505.643.553.552.231.761.40

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.760.760.760.760.760.760.781.001.830.760.760.760.760.760.760.760.760.761.521.52

Thickness (mm)

0.150.510.230.760.800.580.800.400.810.600.800.800.510.510.790.780.780.761.141.52

0.751.701.402.582.802.353.082.403.102.803.463.463.504.003.944.564.566.007.208.65

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2586 AWG NO. 105C 600V VW-1 --- c AWM I/II A/B 105C 600V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned copper conductor, Lead free PVC, FEP or ETFE insulation,Aluminum mylar shield (option), Lead free PVC jacket

Page 25: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

14www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2492345678102345691423462522

3030302828282828282828262626262626262424242422222018

7/0.107/0.107/0.107/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.167/0.167/0.1611/0.167/0.207/0.207/0.2017/0.167/0.2547/0.3241/0.16

38138138123923923923923923923923915015015015015015015094.294.294.294.259.459.436.723.3

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.350.280.230.410.230.230.230.260.260.260.380.230.230.230.400.230.480.480.450.380.230.380.260.380.380.46

1.00x2.000.85x3.850.85x8.211.20x2.500.90x3.440.90x3.900.90x4.900.90x5.900.90x6.900.90x7.901.20x13.001.00x2.271.00x5.000.95x8.451.40x11.400.95x13.501.00x21.001.00x14.001.50x3.101.45x6.451.45x10.451.45x13.951.28x2.661.62x11.781.85x3.802.10x4.30

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2651 AWG NO. 105C 300V VW-1 --- c AWM I A 105C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned or bare copper conductor, 36-14 AWG minimum, Lead free PVC insulation 36-14 AWG

Page 26: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

15 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282228282832282828

44567789

10

7/0.12717/0.1619/0.087/0.1277/0.127TINSEL19/0.087/0.1277/0.127

1.000.450.880.680.900.750.740.740.57

4.304.004.804.305.005.204.804.905.00

23959.4239239239601239239239

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

57/0.1-

16/6/0.1279/0.175/0.1216/7/0.124/5/0.181/0.12

-

Al-MylarAl-Mylar

PaperAl-Mylar

--

PaperPaper

Al-Mylar

No./mm

Braiding ShieldOverallShield

Material

0.220.220.200.220.260.220.230.220.26

0.821.200.800.820.901.000.860.820.90

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21304 & UL21452 : UL21304 UL21452

E148000 AWM STYLE 2835 AWG NO. 60C 30V VW-1 --- c AWM I/II A/B 60C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper, or tinsel conductor, Lead free PVC or PE or PP insulation,Tinned or bare copper drain wire, Tinned or bare copper wire braid shield available, Lead free PVC jacket

3028302630282828

22448

111113

7/0.1019/0.087/0.107/0.167/0.107/0.1277/0.1277/0.127

0.500.400.390.870.700.600.380.53

2.702.202.905.003.505.203.654.50

381239381150381239239239

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

45/0.10-

59/0.1016/5/0.1258/0.10

16/7/0.1216/6/0.1216/5/0.12

No./mm

Braiding/Spiral Shield

0.250.150.250.260.130.220.140.14

0.800.700.801.000.560.820.660.66

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758 & UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21099 & UL21451 : UL21099 UL21451

E148000 AWM STYLE 2725 80C 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, Lead free PVC or SR-PVC insulation,Aluminum mylar shield available, Tinned or bare copper wire braid shield available, Lead free PVC jacket

E148000 AWM STYLE 2725 AWG NO. 80C 30V VW-1 --- c AWM I/II A/B 80C 30V FT1 -LF- PCXX LTK

Page 27: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

16www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2222222333333344444445555555666666777777

30282624222018302826242220183028262422201830282624222018302826242220302826242220

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.167/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.167/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.167/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.167/0.107/0.1277/0.1611/0.1617/0.1626/0.167/0.107/0.1277/0.1611/0.1617/0.1626/0.16

2.402.853.103.153.503.864.342.553.103.103.323.704.084.602.803.303.503.674.034.465.042.853.503.783.994.404.885.533.203.643.944.334.785.323.204.003.944.334.785.32

38123915094.259.436.723.238123915094.259.436.723.238123915094.259.436.723.238123915094.259.436.723.238123915094.259.436.738123915094.259.436.7

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

41/0.146/0.145/0.1262/0.162/0.1272/0.1282/0.1246/0.153/0.162/0.169/0.172/0.1282/0.1296/0.1247/0.1256/0.1263/0.1271/0.1281/0.1292/0.12107/0.1268/0.162/0.127/0.1279/0.1290/0.12103/0.12120/0.1259/0.1271/0.1280/0.1289/0.12101/0.12114/0.1259/0.1271/0.1279/0.1288/0.12101/0.12114/0.12

No./mm/

Spiral Shield

0.230.260.260.260.260.260.260.230.260.260.260.260.260.260.230.260.260.260.260.260.260.230.260.260.260.260.260.260.230.260.260.260.260.260.230.260.260.260.260.26

0.750.901.001.131.281.461.700.750.901.001.131.281.461.700.750.901.001.131.281.461.700.750.901.001.131.281.461.700.750.901.001.131.281.460.750.901.001.131.281.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 2854 AWG NO. 80C 30V VW-1 --- c AWM I/II A/B 80C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, 40 AWG minimum, Lead free PVC or SR-PVC insulation,Tinned or bare copper wire spiral shield, Lead free PVC jacket

40 AWG

Page 28: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

17 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

1CxUL13544CxUL10613CxUL13544CxUL10613CxUL13545CxUL10613CxUL13546CxUL10613CxUL13546CxUL10613CxUL13547CxUL10613CxUL13547CxUL10613CxUL13546CxUL10612CxUL10613CxUL13548CxUL10613CxUL13549CxUL10613CxUL13549CxUL10613CxUL13549CxUL10613CxUL1354

10CxUL10614CxUL13544CxUL10615CxUL13545CxUL13541CxUL10615CxUL13542CxUL1061

28242824282428262824302828243030202828302828262824282628242828262824

7/0.1277/0.20

7/0.1277/0.20

7/0.1277/0.20

7/0.1277/0.16

7/0.1277/0.207/0.10

7/0.1277/0.1277/0.207/0.107/0.10

26/0.167/0.1277/0.1277/0.10

7/0.1277/0.1277/0.16

7/0.1277/0.20

7/0.1277/0.16

7/0.1277/0.20

7/0.1277/0.1277/0.16

7/0.1277/0.20

7.90

8.00

8.00

7.90

8.00

7.20

8.00

7.40

8.00

8.50

8.50

9.40

8.00

8.20

8.85

9.00

9.60

23994.223994.223994.223915023994.238123923994.238138134.623923938123923915023994.223915023994.223923913923994.2

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

1.95

0.85

0.81

0.90

0.85

0.95

0.85

0.85

1.10

0.90

0.85

1.35

0.98

0.78

0.76

0.79

1.00

Thickness (mm)

Jacket

90

90

87

80

85

89.50

85

65

85

85

85

85

83.10

85

-

80

80

Al-Mylar

Al-Mylar

Al-Mylar

Paper

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Al-Mylar

Coverage (%)

Material

Overall Shield

42/0.12-

42/0.12-

42/0.12-

42/0.12-

42/0.12-

39/0.10-

42/0.12-

39/0.10--

42/0.12-

39/0.10-

42/0.12-

42/0.12-

42/0.12-

42/0.12-

42/0.1242/0.12

-16/5/0.10

-

No./mm/

Spiral Shield

0.610.260.610.260.610.260.610.260.610.260.50.260.610.260.50.260.260.610.120.50.260.610.260.610.260.610.260.610.260.610.610.260.610.26

1.601.121.601.121.601.121.601.001.601.121.300.901.601.121.300.821.461.600.631.300.901.601.001.601.101.601.001.601.121.601.601.101.601.12

Thickness (mm)

Diameter (mm)

Insulation

0.35-

0.35-

0.35-

0.35-

0.35-

0.3-

0.35-

0.3--

0.35-

0.3-

0.35-

0.35-

0.35-

0.35-

0.350.35

-0.35

-

2.55-

2.55-

2.55-

2.55-

2.55-

2.10-

2.55-

2.10--

2.55-

2.10-

2.55-

2.55-

2.55-

2.55-

2.552.55

-2.70

-

Thickness (mm)

Diameter (mm)

Covering

E148000 AWM STYLE 2919 AWG NO. 80C 30V VW-1 ---c AWM I/II A/B 80C 30V FT1 -LF- PCXX LOW VOLTAGE COMPUTER CABLE LTK

- First type core: Mini-coaxial cable with foamed PE insulation :

- Second type core: Lead free SR-PVC insulation :

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, Tinned or bare stranded copper drain wire,Tinned or bare copper wire braid shield available, Lead free PVC jacket

Page 29: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

18www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3030302828

10182468

7/0.107/0.107/0.107/0.1277/0.127

0.500.500.500.500.50

3.404.804.553.403.70

381381381239239

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

16/5/0.116/6/0.116/7/0.116/5/0.116/5/0.1

Al-MylarAl-MylarAl-MylarAl-MylarAl-Mylar

No./mm

Overall Shield

Material

0.130.140.130.150.12

0.550.550.550.630.63

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21118 & UL21455 : UL21118 UL21455

E148000 AWM STYLE 20379 AWG NO. 80C 30V VW-1 --- c AWM I/II A/B 80C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, PE insulation,Aluminum mylar shield, Tinned or bare copper wire braid shield, Lead free PVC jacket

2626282828282828282828303028

3P1C3P9C6P7P8P12P1C13P18P19P25P25P

7/0.167/0.167/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.107/0.107/0.127

150150239239239239239239239239239381381239

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Jacket

Paper

Al-Mylar

PETPaperPET

Al-Mylar

Al-MylarAl-MylarAl-MylarAl-MylarAl-Mylar

82

95

709074

84

8580858580

1.05

0.56

0.700.950.70

1.00

0.920.761.281.390.72

6.40

4.70

4.705.305.00

6.70

7.007.408.509.508.20

Coverage (%)

Material

Layer

0.260.260.120.120.120.120.120.120.120.120.120.150.150.12

1.001.000.630.630.630.630.630.630.630.630.630.600.600.63

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Halogen-free Substitution: UL21100 & UL21456 : UL21100 UL21456

E148000 AWM STYLE 20276 AWG NO. 80C 30V VW-1 --- c AWM I/II A/B 80C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded, tinned or bare copper conductor, Lead free PVC, SR-PVC or PP insulation,Aluminum mylar shield, Paper or PET layer, Tinned or bare copper wire braid shield, Lead free PVC jacket

Page 30: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

19 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

302624343232303030

2C4C4C4P1P5C4P1P5C

TC* - Tinned Copper

7/0.101/0.407/0.207/0.067/0.087/0.081/0.2541/0.2541/0.254

38114887.6978601601347347347

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Jacket

TC*Al-MylarAl-Mylar

TC*

TC*

902525

85

90

0.330.50x0.50

0.45

0.40

0.51

3.002.20x7.902.40x4.80

4.50

6.20

Coverage (%)

Material

Overall Shield

0.300.350.150.110.100.100.270.170.17

0.901.100.950.500.500.500.800.600.60

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60, 80, 90, or 105°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 vertical flame test UL VW-1

E148000 AWM STYLE 21149 XXXC 30V VW-1 -LF- PCXX LTK

E148000 AWM STYLE 21149 XXXC 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid, tinned or bare copper conductor, Lead free FEP, FM-PE, PP, PVC or XLPE insulation,Aluminum mylar, tinned copper wire braid or spiral shield, Lead free PVC jacket

Page 31: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

20www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

30282624222018

7/0.107/0.1277/0.167/0.207/0.2547/0.32

16/0.254

0.300.380.480.600.761.001.16

0.300.330.280.330.330.330.42

1.001.051.101.301.421.802.00

38123915094.259.436.723.2

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 3443 AWG NO. 105C 300V VW-1 - - - c AWM I A/B 105C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-10 AWG, Lead free XL-PVC insulation 32-10 AWG

303030282826

78

1668

20

7/0.107/0.107/0.107/0.1277/0.1277/0.16

381381381239239150

Conductor

AWGNo.of Cores No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Jacket

PaperPaperPaper

-PaperPaper

252525-

2525

0.530.530.380.580.450.82

3.103.303.904.003.909.00

Coverage (%)

Material

Layer

0.180.180.180.260.250.38

0.650.650.650.890.881.30

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21520 AWG NO.105C 300V VW-1 ---c AWM I A 105C 300V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned copper conductor, Lead free PVC or XLPE insulation,Paper tape layer available, XLPE jacket

Page 32: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 33: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 34: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

23 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.200.210.210.200.200.250.260.26

0.700.800.901.001.161.441.702.00

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10212 AWG NO. 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 36 AWG minimum, FRPE insulation 36 AWG

30282624

7/0.107/0.1277/0.167/0.20

0.300.380.480.60

0.540.550.650.64

1.902.002.302.40

38123915094.2

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.260.260.260.26

0.820.901.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 1354 AWG NO. 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 44 AWG minimum, PE, FRPE or PP insulation,Spiral or braid shield, FRPE, XLPE or PET jacket

44 AWG

Page 35: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

24www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.260.260.260.260.260.260.270.26

0.820.901.001.121.281.461.702.00

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10533 AWG NO. 80˚C 600V VW-1 --- c AWM I A 80˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 36-14 AWG, FRPE insulation 36-14 AWG

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

28262422201816141210

7/0.1277/0.167/0.2017/0.1626/0.1616/0.25426/0.25441/0.25465/0.25466/0.32

0.380.480.600.760.941.181.491.872.363.00

0.260.260.260.260.260.270.410.410.600.60

0.901.001.121.281.461.702.312.703.564.20

23915094.259.436.723.214.68.965.643.55

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL10981 : UL10981

E148000 AWM STYLE 10368 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid silver plated, tinned or bare copper conductor, 40-10 AWG, XLPE insulation 40-10 AWG

Page 36: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

25 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.530.550.550.550.570.580.550.60

1.751.902.002.102.302.602.803.20

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.200.210.210.200.200.250.270.26

0.700.800.901.001.161.441.702.00

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10796 AWG NO. 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, Spiral or braid shield, FRPE jacket

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.260.260.260.260.260.260.270.26

0.820.901.001.121.281.461.702.00

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10602 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid silver plated, tinned or bare copper, 40-10 AWG, FRPE insulation 40-10 AWG

Page 37: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

26www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.920.900.900.920.910.950.930.93

2.652.702.802.953.103.353.553.85

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.270.26

0.820.901.001.121.281.461.702.00

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10801 AWG NO. 80˚C 300V VW-1 --- c AWM I/II A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, Spiral or braid shield, FRPE jacket

- Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL10983 : UL10983

E148000 AWM STYLE 10800 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, FRPE jacket

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.450.450.450.450.480.480.450.48

1.801.902.002.102.302.502.703.10

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.300.310.310.300.300.310.320.33

0.901.001.101.201.351.551.802.15

Thickness (mm)

Diameter (mm)

Insulation

Page 38: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

27 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL11045 : UL11045

E148000 AWM STYLE 10937 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE or XLPE insulation, XLPE jacket

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.450.450.450.450.480.480.450.48

1.801.902.002.102.302.502.703.10

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.300.310.310.300.300.310.320.33

0.901.001.101.201.351.551.802.15

Thickness (mm)

Diameter (mm)

Insulation

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.540.550.550.570.560.570.600.58

1.902.002.102.252.402.602.903.15

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.270.26

0.820.901.001.121.281.461.702.00

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10804 AWG NO. 80˚C 600V VW-1 --- c AWM I A 80˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, Spiral or braid shield, FRPE jacket

Page 39: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

28www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

26262424222220

3456783

7/0.167/0.167/0.207/0.2017/0.1617/0.1626/0.16

4.304.505.205.506.106.405.30

15015094.294.259.459.436.7

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.26

1.001.001.121.121.281.281.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 20233 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 36 AWG minimum, FRPE insulation,Aluminum foil, braid or spiral shield, PU jacket

36 AWG

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.161.49

0.350.350.350.350.350.350.350.35

2.602.682.782.913.063.243.483.79

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.800.800.800.800.800.800.800.80

1.901.982.082.202.362.542.763.09

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL11047 : UL11047

E148000 AWM STYLE 10938 AWG NO. 105˚C 600V VW-1 --- c AWM I A 105˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE or XLPE insulation, XLPE jacket

Page 40: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

29 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

303028282828262626262424

7P5C4P5C7P5C4P5C7P5C4P5C

7/0.107/0.107/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.207/0.20

38138123923923923915015015015094.294.2

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Diameter (mm)

Jacket

PET Tape /Al-Mylar /Drain Wire

Braiding,Al-Mylar

6.30

6.90

7.80

7.80

9.00

9.00

Inner Outer

Shield Material

0.800.540.900.900.900.901.251.001.251.001.601.12

Diameter (mm)

Insulation - Rated temperature : 60 or 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21455 (Rate temperature : 80°C) : UL21455 ( : 80°C)

E148000 AWM STYLE 20855 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, Foam PE or PP insulation,Aluminum mylar and braid shield, FRPE jacket

40 AWG

32303028303030282828262626242626222626

4P1P4C1C4P1P5C4P1P5C4P1P5C4P1P5C4P1P5C

7/0.087/0.107/0.107/0.1277/0.107/0.107/0.107/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.207/0.167/0.167/0.2547/0.167/0.16

57838138123938138138123923923915015015094.215015059.4150150

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Diameter (mm)

Jacket

PET Tape /Al-Mylar /Drain Wire

Braiding,Al-Mylar

5.40

5.70

7.30

8.20

9.30

10.20

Inner Outer

Shield Material

0.680.540.540.600.800.540.540.950.700.701.251.001.001.601.001.001.801.001.00

Diameter (mm)

Insulation - Rated temperature : 60 or 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21456 (Rate temperature : 80°C) : UL21456 ( : 80°C)

E148000 AWM STYLE 20851 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, Foam PE or PP insulation,Aluminum mylar and braid shield, FRPE jacket

40 AWG

Page 41: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

30www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.603.804.304.604.903.904.805.604.90

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21088 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, PE insulation,Braid or spiral shield, FRPE jacket

40 AWG

23452345234523452

2828282826262626242424242222222220

7/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.207/0.207/0.207/0.2017/0.1617/0.1617/0.1617/0.1626/0.16

23923923923915015015015094.294.294.294.259.459.459.459.436.7

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.90x1.900.90x2.900.90x3.900.90x4.901.00x2.101.00x3.201.00x4.301.00x5.401.12x2.341.12x3.561.12x4.781.12x6.001.28x2.661.28x4.041.28x5.421.28x6.801.46x3.02

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21016 AWG NO. 105˚C 300V VW-1 ---c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40-10 AWG, XLPE jacket 40-10 AWG

Page 42: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

31 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.603.804.304.604.903.904.805.604.90

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21456 : UL21456

E148000 AWM STYLE 21100 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, PE insulation,Braid or spiral shield, FRPE jacket

40 AWG

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.203.503.704.004.303.404.305.204.40

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21451 : UL21451

E148000 AWM STYLE 21099 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, PE insulation,Aluminum mylar shield, FRPE jacket

40 AWG

Page 43: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

32www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

26262424222220

3456783

7/0.167/0.167/0.207/0.2017/0.1617/0.1626/0.16

4.304.505.205.506.106.405.30

15015094.294.259.459.436.7

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.26

1.001.001.121.121.281.281.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21143 AWG NO. 80˚C 300V VW-1 --- c AWM I/II A/B 80˚C 300V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 26-16 AWG, FRPE insulation,Braid or spiral shield, FRPE jacket

26-16 AWG

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.604.104.304.605.003.905.105.805.20

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21455 : UL21455

E148000 AWM STYLE 21118 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 50 AWG minimum, PE insulation,Aluminum mylar, braid shield, FRPE jacket

50 AWG

Page 44: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

33 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.1611/0.16

3.604.104.304.605.003.905.105.805.20

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21305 AWG NO. 60˚C 300V VW-1 --- c AWM I/II A/B 60˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, FRPE insulation,Aluminum mylar, braid shield, FRPE jacket

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.1611/0.16

3.604.104.304.605.003.905.105.805.20

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21452 : UL21452

E148000 AWM STYLE 21304 AWG NO. 60˚C 30V VW-1 --- c AWM I/II A/B 60˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation,Aluminum mylar, braid shield, FRPE jacket

Page 45: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

34www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

234523452345234522

282828282626262624242424222222222018

7/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.207/0.207/0.207/0.2017/0.1617/0.1617/0.1617/0.1626/0.1641/0.16

23923923923915015015015094.294.294.294.259.459.459.459.436.723.2

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

1.24x2.581.24x3.921.24x5.261.24x6.601.34x2.781.34x4.221.34x5.661.34x7.101.45x3.001.45x4.551.45x6.101.45x7.651.62x3.341.62x5.061.62x6.781.62x8.501.80x3.702.04x4.23

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21458 : UL21458

E148000 AWM STYLE 21311 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 32-16 AWG, FRPE jacket 32-16 AWG

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.1611/0.16

3.604.104.304.605.003.905.105.805.20

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL21457 : UL21457

E148000 AWM STYLE 21307 AWG NO. 80˚C 300V VW-1 --- c AWM I/II A/B 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, FRPE insulation,Aluminum mylar, braid shield, FRPE jacket

Page 46: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

35 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.420.410.410.420.420.420.410.42

1.141.201.301.441.601.782.002.32

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 3199 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 30-16 AWG, XLPE insulation 30-16 AWG

262422201816

7/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.480.600.760.941.181.49

0.810.800.800.810.820.81

2.102.202.362.552.803.10

15094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3173 AWG NO. 125˚C 600V H --- c AWM I A 125˚C 600V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 26-9 AWG, XLPE insulation 26-9 AWG

Page 47: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

36www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.420.410.410.420.420.420.410.42

0.901.001.101.301.401.601.902.20

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 150V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3265 AWG NO. 125˚C 150V H --- c AWM I A 125˚C 150V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 32-16 AWG, XLPE insulation 32-16 AWG

2424

19/0.12719/0.127

0.640.64

0.550.48

1.741.60

94.294.2

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 3kV, 6kV

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 127

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 3239 AWG NO. 105˚C XXKVDC VW-1 --- c TV-XX 105˚C XXKVDC FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned copper conductor, 24-10 AWG, XLPE insulation 24-10 AWG

Page 48: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

37 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

26242220181614

7/0.167/0.2017/0.1626/0.1641/0.1626/0.25441/0.254

0.480.600.760.941.181.491.87

0.810.800.800.810.820.810.82

2.102.202.362.552.803.103.50

15094.259.436.723.214.68.96

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3271 AWG NO. 125˚C 600V H --- c AWM I A 125˚C 600V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 30AWG - 1000kcmil, XLPE insulation 30AWG - 1000kcmil

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.420.410.410.420.420.420.410.42

1.141.201.301.441.601.782.002.32

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3266 AWG NO. 125˚C 300V H --- c AWM I A 125˚C 300V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 32-10 AWG, XLPE insulation 32-10 AWG

Page 49: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

38www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

32302826

7/0.087/0.1070.1277/0.16

0.240.300.380.48

0.160.170.210.26

0.560.640.801.00

578381239150

- Rated temperature : 105°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 3302 AWG NO. 105˚C 30V VW-1 --- c AWM I A 105˚C 30V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 40 AWG minimum, XLPE insulation 40 AWG

262422201816

7/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.480.610.760.941.181.49

0.810.800.800.810.820.81

2.102.202.362.552.803.10

15094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 1kV

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL11029 : UL11029

E148000 AWM STYLE 3275 AWG NO. 105˚C 1000V VW-1 --- c AWM I A 105˚C 1000V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 26-9 AWG, XLPE insulation 26-9 AWG

Page 50: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

39 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

28262422201816

7/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.380.480.610.760.941.181.49

0.300.300.300.300.300.300.30

1.781.882.002.162.342.582.89

23915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.400.400.400.400.400.400.40

1.181.281.401.561.741.982.29

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3363 AWG NO. 125˚C 300V H --- c AWM I A 125˚C 300V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-10 AWG, XLPE insulation and jacket 32-10 AWG

26242220181614

7/0.167/0.2017/0.1626/0.1641/0.1626/0.25441/0.254

0.480.600.760.941.181.491.87

0.810.800.800.810.820.810.82

2.102.202.362.552.803.103.50

15094.259.436.723.214.68.96

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3343 AWG NO. 125˚C 600V H --- c AWM I A 125˚C 600V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 30-4/0 AWG, XLPE insulation 30-4/0 AWG

Page 51: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

40www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

302826242220181614

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.254

0.300.380.480.610.760.941.181.491.87

0.800.800.800.800.810.800.810.820.82

1.901.982.082.212.382.542.803.123.50

38123915094.259.436.723.214.68.96

- Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL11028 : UL11028

E148000 AWM STYLE 3386 AWG NO. 105˚C 600V VW-1 --- c AWM I A 105˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-16 AWG, XLPE insulation 32-16 AWG

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1619/0.2041/0.1626/0.254

0.300.380.480.600.761.001.181.49

0.400.400.400.420.400.370.410.40

1.101.181.281.431.561.742.002.28

38123915094.259.436.723.214.6

- Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- mPPE Substitution: UL10982 & UL11027 : UL10982 UL11027

E148000 AWM STYLE 3385 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, 32-10 AWG, XLPE insulation 32-10 AWG

Page 52: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

41 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.200.210.210.200.200.250.260.26

0.700.800.901.001.161.441.702.00

38123915094.256.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 125°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3417 AWG NO. 125˚C 30V H --- c AWM I A 125˚C 30V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40 AWG minimum, XLPE insulation 40 AWG

28262422201816

7/0.1277/0.1619/0.121/0.64320/0.1841/0.1654/0.18

0.380.480.600.640.921.181.53

0.410.410.400.380.410.380.44

1.201.301.481.501.822.002.40

22313994.256.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 150°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 3398 AWG NO. 150˚C 300V H --- c AWM I A 150˚C 300V FT2 -F- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded tinned copper conductor, 32-10 AWG, XLPE insulation 32-10 AWG

Page 53: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

42www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

210141634810

2828282826262626

7/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.16

239239239239150150150150

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.90x1.900.90x12.330.90x17.410.90x19.950.95x6.000.95x7.000.95x12.000.95x20.00

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL H & CSA FT2 horizontal flame test UL H CSA FT2

E148000 AWM STYLE 4478 AWG NO. 105C 300V H --- c AWM I A 105C 300V FT2 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 36-10 AWG, XLPE insulation 36-10 AWG

Page 54: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 55: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 56: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

45 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.410.410.410.410.410.410.410.41

1.121.201.301.431.581.762.002.31

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10982 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid tinned or bare copper conductor, 32-16 AWG, mPPE-PE insulation 32-16 AWG

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.260.260.260.260.260.260.410.41

0.820.901.001.121.281.462.002.31

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10981 AWG NO. 80˚C 300V VW-1 --- c AWM I/II A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 30-16 AWG, mPPE-PE insulation 30-16 AWG

Page 57: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

46www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.300.380.480.610.760.941.181.49

0.420.420.420.420.420.420.420.42

1.741.821.922.042.202.382.622.93

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.300.300.300.300.300.300.300.30

0.900.981.081.201.361.541.782.09

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10984 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid tinned or bare copper conductor, 30-16 AWG, mPPE-PE insulation and jacket 30-16 AWG

22201816

17/0.1626/0.1641/0.1626/0.254

0.760.941.181.49

0.640.650.680.72

2.853.103.403.80

59.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.410.430.430.44

1.581.802.042.36

Thickness Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10983 AWG NO. 80˚C 300V VW-1 --- c AWM I A 80˚C 300V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid tinned or bare copper, PE insulation, Spiral shield, mPPE-PE jacket

Page 58: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

47 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

262422201816141210

7/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.25465/0.25466/0.32

0.480.610.760.941.161.491.872.363.00

0.400.400.400.400.400.800.800.790.78

1.281.401.561.741.963.083.463.944.56

15094.259.436.723.214.68.965.643.55

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 1000V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10987 AWG NO. 80˚C 1000V VW-1 --- c AWM I A 80˚C 1000V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid tinned or bare copper conductor, 30AWG - 500kcmil, mPPE-PE insulation 30AWG - 500kcmil

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.560.570.570.560.550.560.560.58

2.252.352.452.552.702.903.203.50

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.420.420.420.420.420.420.430.43

1.141.221.321.441.601.782.052.35

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 10986 AWG NO. 80˚C 600V VW-1 --- c AWM I A 80˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid tinned or bare copper conductor, 30-4/0 AWG, mPPE-PE insulation,Spiral or braid shield, mPPE-PE jacket

30-4/0 AWG

Page 59: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

48www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

323028262422201816141210

7/0.087/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.25465/0.254

105/0.254

0.240.300.380.480.610.760.941.181.491.872.363.00

0.260.260.260.260.260.260.260.260.410.420.420.60

0.760.820.901.001.121.281.461.702.302.703.204.20

59738123915094.259.436.723.214.68.965.643.55

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11027 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 40-10 AWG, mPPE insulation 40-10 AWG

323028262422201816

7/0.087/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.254

0.240.300.380.480.610.760.941.181.49

0.220.220.220.220.220.220.310.310.31

0.680.740.820.921.051.201.561.802.11

57838023915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11025 AWG NO. 105˚C 30V VW-1 --- c AWM I A 105˚C 30V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 40-10 AWG, mPPE insulation 40-10 AWG

Page 60: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

49 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

323028262422201816141210

7/0.087/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.25465/0.254

105/0.254

0.240.300.380.480.610.760.941.181.491.872.363.00

0.810.800.810.810.800.810.810.810.810.820.820.83

1.851.902.002.102.202.382.562.803.103.504.004.66

59738123915094.259.436.723.214.68.965.643.55

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 1kV

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11029 AWG NO. 105˚C 1000V VW-1 --- c AWM I A 105˚C 1000V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 40-10 AWG, mPPE insulation 40-10 AWG

323028262422201816141210

7/0.087/0.107/0.1277/0.1611/0.1617/0.1626/0.1641/0.1626/0.25441/0.25465/0.254105/0.254

0.240.300.380.480.610.760.941.181.491.872.363.00

0.410.410.410.410.410.410.410.410.410.420.420.60

1.051.121.201.301.431.581.762.002.302.703.204.20

59738123915094.259.436.723.214.68.965.643.55

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11028 AWG NO. 105˚C 600V VW-1 --- c AWM I A 105˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded or solid bare or tinned copper conductor, 40-10 AWG, mPPE insulation 40-10 AWG

Page 61: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

50www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.290.300.300.290.310.300.300.30

1.401.501.601.701.902.152.402.75

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.260.260.260.260.260.310.310.33

0.820.901.001.121.281.551.802.15

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11047 AWG NO. 105˚C 600V VW-1 --- c AWM I A 105˚C 600V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, mPPE jacket

3028262422201816

7/0.107/0.1277/0.167/0.2017/0.1626/0.1641/0.1626/0.254

0.300.380.480.600.760.941.181.49

0.290.300.300.290.310.300.300.30

1.401.501.601.701.902.152.402.75

38123915094.259.436.723.214.6

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.260.260.260.260.260.310.310.33

0.820.901.001.121.281.551.802.15

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 11045 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1-F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation, mPPE jacket

Page 62: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

51 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.604.104.304.605.003.905.105.805.20

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21452 AWG NO. 60˚C 30V VW-1 --- c AWM I A 60˚C 30V FT1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper or tinsel conductor, PE or PP insulation,Aluminum mylar, braid shield, mPPE-PE jacket

28282826282428222820

4

4

4

4

4

7/0.1277/0.1277/0.1277/0.167/0.1277/0.207/0.1277/0.2547/0.12726/0.16

4.20

4.80

4.90

5.10

5.10

23923923915023994.223959.423936.7

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.210.260.210.260.210.260.210.260.210.26

0.750.900.751.000.751.120.751.280.751.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21451 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation,Aluminum mylar, braid shield, mPPE-PE jacket

Page 63: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

52www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

32303028303030282828222626

4P1P4C1C4P1P5C4P1P5C4P1P5C

7/0.087/0.107/0.107/0.1277/0.107/0.107/0.107/0.1277/0.1277/0.12719/0.1477/0.167/0.16

57838138123938138138123923923959.4150150

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Diameter (mm)

Jacket

Al-MylarBraiding,Al-Mylar

5.40

5.70

7.30

10.20

Inner Outer

Shield Material

0.680.540.540.600.800.540.540.950.700.701.801.001.00

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21456 AWG NO. 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, Foam PE or PP insulation,Aluminum mylar and braid shield, mPPE-PE jacket

3030282828282626262624242424

7P5C4P5C7P5C4P5C7P5C4P5C7P5C

7/0.107/0.107/0.1277/0.1277/0.1277/0.12719/0.1019/0.1019/0.1019/0.1019/0.12719/0.1277/0.207/0.20

38138123923923923915015015015094.294.294.294.2

Conductor

AWGConstruction (Cores/Pairs)

No./mm/

Max. DC

Resistance

at 20°C

(ohm/km)

Diameter (mm)

Jacket

Al-MylarBraiding,Al-Mylar

6.30

6.90

7.80

7.80

9.00

9.00

12.50

Inner Outer

Shield Material

0.800.540.900.900.900.901.251.001.251.001.601.121.361.00

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21455 AWG NO. 80˚C 30V VW-1 --- c AWM I A 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, Foam PE or PP insulation,Aluminum mylar and braid shield, mPPE-PE jacket

Page 64: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

53 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

23456723456723456723456722

2828282828282626262626262424242424242222222222222018

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.167/0.167/0.207/0.207/0.207/0.207/0.207/0.207/0.2547/0.2547/0.2547/0.2547/0.2547/0.25426/0.1641/0.16

23923923923923923915015015015015015094.294.294.294.294.294.259.459.459.459.459.459.436.723.3

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.430.43

1.24x2.581.24x3.921.24x5.261.24x6.601.24x7.941.24x9.281.34x2.781.34x4.221.34x5.661.34x7.101.34x8.541.34x10.001.45x3.041.45x4.631.45x6.221.45x7.811.45x9.401.45x11.001.62x3.341.62x5.061.62x6.781.62x8.501.62x10.221.62x11.941.80x3.702.04x4.23

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21458 AWG NO. 80˚C 300V VW-1 --- c AWM I A AWM 80˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 32-16 AWG, mPPE-PE insulation 32-16 AWG

26262424222220

3456783

7/0.167/0.167/0.207/0.2017/0.1617/0.1626/0.16

3.804.104.805.205.706.205.00

15015094.294.259.459.436.7

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.26

1.001.001.121.121.281.281.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21457 AWG NO. 80˚C VW-1 --- c AWM I A 80˚C 300V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 30-16 AWG, mPPE-PE insulation,Braid or spiral shield, mPPE-PE jacket

30-16 AWG

Page 65: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

54www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

4.004.304.604.905.204.305.206.005.30

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 60°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21474 AWG NO. 60˚C 30V VW-1 --- c AWM I/II A/B 60˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation,Aluminum mylar, braid shield, mPPE-PE jacket

26262424222220

3456783

7/0.167/0.167/0.207/0.2017/0.1617/0.1626/0.16

3.804.104.805.205.706.205.00

15015094.294.259.459.436.7

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.26

1.001.001.121.121.281.281.46

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 600V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21461 AWG NO. 80˚C 600V VW-1 --- c AWM I A 80˚C 600V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 40AWG - 2000kcmil, mPPE-PE insulation,Braid or spiral shield, mPPE-PE jacket

40AWG - 2000kcmil

Page 66: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

55 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3456789

1011123456789

101112

2828282828282828282826262626262626262626

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.167/0.167/0.167/0.167/0.167/0.167/0.16

239239239239239239239239239239150150150150150150150150150150

Conductor

No.of Cores AWG No./mm/

Max. DC Resistance

at 20°C

(ohm/km)

0.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.23

0.90x2.700.90x3.600.90x4.500.90x5.400.90x6.300.90x7.200.90x8.100.90x9.000.90x9.900.90x10.801.00x3.001.00x4.001.00x5.001.00x6.001.00x7.001.00x8.001.00x9.001.00x10.001.00x11.001.00x12.00

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758 & UL1581

- Passes UL VW-1 vertical flame test UL VW-1

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 36-14 AWG, mPPE insulation 36-14 AWG

E148000 AWM STYLE 21515 AWG NO. 105˚C 300V VW-1 ---c AWM I A/B 105˚C 300V FT1 -HF- -LF- PCXX LTK

282828282826262624

345683695

7/0.1277/0.1277/0.1277/0.1277/0.1277/0.167/0.167/0.167/0.20

3.203.503.704.004.303.404.305.204.40

23923923923923915015015094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.260.260.260.260.260.260.26

0.900.900.900.900.901.001.001.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21476 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A/B 80˚C 30V FT1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, PE insulation,Aluminum mylar shield, mPPE-PE jacket

Page 67: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

56www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

282624

223

7/0.1277/0.167/0.20

1.80x3.701.90x3.902.10x5.40

23915094.2

Conductor

AWGNo.of Cores No./mm/

Max. DC Resistance

at 20°C

(ohm/km)Diameter

(mm)

Jacket

0.260.260.26

0.901.001.12

Thickness (mm)

Diameter (mm)

Insulation - Rated temperature : 105°C

- Rated voltage : 300V

- Reference standard : UL 758, UL1581 & CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E148000 AWM STYLE 21517 AWG NO. 105˚C 300V VW-1 --- c AWM I A 105˚C 300V FT1 -F- -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Stranded bare or tinned copper conductor, 36-14 AWG, mPPE insulation Braid or spiral shield, mPPE jacket

36-14 AWG

Page 68: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 69: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 70: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

59 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Diameter(mm)

Construction Material Diameter(mm)

Braid

Shielding

343630

7/0.067/0.05

7/0.10+200DK

0.180.150.33

4P2C4C

FEPPFAFEP

0.490.260.51

Material Diameter(mm)

TPE 4.509281582381

TinnedCopper

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758

- Passes UL VW-1 vertical flame test UL VW-1

- Inter Delay Skew : <=30ps/2m

- Impedance : 100+/-7Ω

- Near End Crosstalk : Frequency (GHz) Attn (dB/2m) 4 Pairs 0.01-5 50 2 Cores 350MHz 25

- Far End Crosstalk : Frequency (MHz) Attn (dB/m) 0.01-15 56

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Diameter(mm)

Construction Material Diameter(mm)

Braid

Shielding

342832

322432

302632

282432

262432

7/0.0647/0.1277/0.08

7/0.087/0.207/0.08

7/0.107/0.167/0.08

7/0.1277/0.207/0.08

7/0.167/0.207/0.08

0.180.380.24

0.240.600.24

0.300.480.24

0.380.600.24

0.480.600.24

1P2C1C

1P2C1C

1P2C1C

1P2C1C

1P2C1C

FEPHDPE

Foam PE

Foam PEHDPE

Foam PE

Foam PEPP

Foam PE

Foam PEPP

Foam PE

Foam PEPP

Foam PE

0.500.850.60

0.601.100.60

0.821.300.60

0.951.500.60

1.251.800.60

Material Diameter(mm)

NHFR

NHFR

NHFR

* NHFR / PVC

* NHFR / PVC

3.00

4.20

4.30

5.40

6.20

997237613

61395.8613

381150613

24495.8613

15395.8613

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

* NHFR Jacket

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, MHL1.0

- Passes UL VW-1 vertical flame test UL VW-1

- Propagation Delay : <=35ns/0.5m

- Intra Delay Skew : <=43ps/0.5m

- Common Impedance : 30+/-5Ω ((20%-80%) of 600 psec)

- Differential Impedance : 100+/-5Ω ((20%-80%) of 200 psec)

Halogen-Free : E148000 AWM STYLE 21456 80˚C 30V VW-1 -HF- -LF- PCXX LTK

PVC : E148000 AWM STYLE 20276 80˚C 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

Page 71: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

60www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Overall

Shielding

3030

2828

3030

3232

3030

2828

7/0.107/0.10

7/0.1277/0.127

7/0.107/0.10

7/0.087/0.08

7/0.107/0.10

7/0.1277/0.127

5P4C

5P4C

5P4C

5P5C

5P4C

5P4C

Foam PEPE

Foam PEPE

Foam PEPE

Foam PEHD-PE

Foam PEHD-PE

Foam PEHD-PE

0.820.55

0.950.70

0.780.55

0.660.50

0.820.55

0.950.70

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

PVC

PVC

PVC

FRPE

FRPE

FRPE

6.50

7.30

6.60

6.00

6.60

7.80

340

223

340

574

354

223

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

Version

1.2

1.2

1.1

1.1

1.1

1.1

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL 1581, DisplayPort 1.1, DisplayPort 1.2

- Passes UL VW-1 vertical flame test UL VW-1

- Propagation Delay : <=4.85ns/m

- Delay Skew : Intra <=50ps, Inter <=4000ps

- Impedance : 100+/-5Ω

- Return Loss : 15.00dB

- Near End Crosstalk : 26.00dB

- Far End Crosstalk : 26.00dB

Halogen-Free : E148000 AWM STYLE 21088 80˚C 30V VW-1 DP CABLE -HF- -LF- PCXX LTK

PVC : E148000 AWM STYLE 20276 80˚C 30V VW-1 DP CABLE -LF- PCXX LTK

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Overall

Shielding

303030

282828

403632

363636

343434

282828

262828

7/0.107/0.107/0.10

7/0.1277/0.1277/0.127

7/0.037/0.057/0.09

7/0.057/0.057/0.05

7/0.067/0.067/0.06

19/0.0819/0.0819/0.08

7/0.167/0.1277/0.127

4P1P4C

4P1P4C

8C10C1C

4P1P5C

4P1P5C

4P1P4C

4P1P4C

Foam PEFoam PEHD-PE

Foam PEFoam PEHD-PE

PFAPFAPFA

HD-PEHD-PEHD-PE

PPPPPP

Foam PEFoam PE

PE

Foam PEFoam PEHD-PE

0.820.820.55

0.950.950.70

0.180.300.57

0.400.500.50

0.530.500.50

1.001.000.70

1.250.950.70

Material Diameter(mm)

PVC

PVC

PVC

NHFR

NHFR

PVC

PVC

6.50

7.50

2.80

4.00

4.50

7.50

8.30

354

223

50001582613

1473

997

223

233

TinnedCopper

TinnedCopper

Spiral BraidingTinned Copper

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

Version

2.0

2.0

1.4

1.4

1.4

1.4

1.4

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, HDMI 1.4, HDMI 2.0

- Passes UL VW-1 vertical flame test UL VW-1

- Delay Skew : Intra <=111ps Inter <=1.78ns

- Impedance : 100+/-10Ω

- Far End Crosstalk : 26.00dB

- Attenuation : Frequency Attn (dB/m)

Halogen-Free : E148000 AWM STYLE 21456 80˚C 30V VW-1 -HF- -LF- PCXX LTK

PVC : E148000 AWM STYLE 2725 80˚C 30V VW-1 -LF- PCXX LTK

HIGH SPEED HDMI® CABLE WITH ETHERNET E148000 AWM STYLE 20276 80˚C 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

300KHz - 825MHz825MHz - 2.475GHz2.475 - 4.125GHz

4.125 - 5.1GHz

<=5<=12<=20<=25

Page 72: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

61 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Inner

Shielding

3028

3030

2828

7/0.107/0.127

7/0.107/0.10

7/0.1277/0.127

3C6C

3C5C

3C6C

PEPP

PEPP

PEPP

1.350.85

1.350.70

1.650.85

Spiral-

Spiral-

Spiral-

Overall

Shielding

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

381239

381381

239239

FRPE

FRPE

FRPE

6.30

5.50

6.50

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL 1581, CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

- Impedance : 75+/-5Ω

E148000 AWM STYLE 21118 AWG NO. 80˚C 30V VW-1 --- c AWM I/II A 80˚C 30V FT-1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Construction Material Diameter(mm)

302828

2626

3030

2830

7/0.107/0.1277/0.127

19/0.1019/0.10

7/0.107/0.10

7/0.1277/0.10

7P1P3C

4P5C

4P5C

7P10C

*SFS-PEHD-PEHD-PE

FM-PEHD-PE

**FS-PEHD-PE

FM-PEHD-PE

1.641.40

-

1.251.00

0.820.54

0.950.55

Overall

Shielding

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

365224224

140140

365365

223354

NHFR

NHFR

PVC

PVC

7.50

7.80

6.00

8.30

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

* SFS-PE : Skin-Foam-Skin PE ** FS-PE : Foam-Skin PE

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL 1581, CSA C22.2 No.210.2

- Passes UL VW-1 vertical flame test UL VW-1

- Propagation Delay : <=5.05ns/m

- Delay Skew : Intra <=151ps

- Impedance : 100+/-10Ω

- Attenuation : <=2.0dB/m (800MHz)

Halogen-Free : E148000 AWM STYLE 21455 80˚C 30V VW-1 DVI DIGITAL SINGLE/DUAL LINK -HF- -LF- PCXX LTK

PVC : E148000 AWM STYLE 20379 80˚C 30V VW-1 DVI DIGITAL SINGLE/DUAL LINK PCXX LTK

PRODUCT DESCRIPTION

Page 73: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

62www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Overall

Shielding

3232302822

7/0.087/0.087/0.1

7/0.1277/0.254

2P2P2P2P2C

PEFoam-PEFoam-PEFoam-PE

PE

0.540.680.801.001.40

59759735422357.5

-Al-MylarAl-MylarBraidingAl-Mylar

FRPEFRPEFRPE

FRPE

4.004.104.80

6.10

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

100200400

2.33.25.8

100200300

71012

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : IEEE1394-1995 & P1394a, IEC60754-2

- Passes UL VW-1 vertical flame test UL VW-1

- DV-400 Electrical Performance

- Propagation Delay : <=5.05ns/m

- Propagation Delay Skew : <=400ps/4.5m

- Crosstalk : >=26dB

- Impedance (at 20°C) : 110+/-6Ω

- Attenuation : Frequency (MHz) Attn (dB/10m)

- DV-100 Electrical Performance

- Impedance (at 20°C) : 110+/-6Ω

- Attenuation : Frequency (MHz) Attn (dB/10m)

E148000 AWM STYLE 21088 80˚C 30V VW-1 ULTRA HIGH SPEEDSERIAL INTERFACE CABLE IEEE 1394 COMPLIANT -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Braid

Shielding

3030

3030

3030

7/0.107/0.10

7/0.107/0.10

7/0.107/0.10

5P5C

9P9C

10P11C

PPPP

FM-PEPE

HDFM-PESR-PVC

0.580.60

0.700.70

0.550.60

TinnedCopper

TinnedCopper

TinnedCopper

PVC

PVC

PVC

4.90

7.20

6.00

381

419

354

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL 1581

- Passes UL VW-1 vertical flame test UL VW-1

- Impedance : 100+/-10Ω

E148000 AWM STYLE 20276 80˚C 30V VW-1 -HF- -LF- PCXX LTK

PRODUCT DESCRIPTION

Page 74: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

63 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Diameter(mm)

Construction Material Diameter(mm)

Overall

Shielding

2626

1/0.411/0.41

0.410.41

2P2P

Foam PEFoam PE

1.11.1

Al-MylarAl-Mylar

PVCFRPE

2.2x7.92.2x7.9

100100

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL 1581, Serial ATA Specification, IEC60754-2

- Passes UL VW-1 vertical flame test UL VW-1

- Delay Skew : Intra <=10ps, Inter <=50ps

- Impedance : 100+/-5Ω

- Rise Time : 85ps (35 ps input, @20%~80%) (Max.)

- Crosstalk : -26dB (@10~4500MHz) (Max.)

- Attenuation : 6dB/m (@10~4500MHz) (Max.)

Halogen-Free : E148000 AWM STYLE 21099 80˚C 300V VW-1 --- c AWM I/II A/B 80˚C 300V FT1Serial ATA 2 Pairs/AWG NO. 100ohm -HF- -LF- PCXX LTK

PVC : E148000 AWM STYLE 2725 80˚C 30V VW-1 --- Serial ATA 2 Pairs/AWG NO. 100ohm PCXX LTK

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Braid

ShieldingVersion

303026

283026

282824

323228

2827

3.1

3.1

3.1

3.0

2.0

7/0.107/0.107/0.16

7/0.1277/0.107/0.16

7/0.1277/0.1277/0.20

7/0.087/0.087/0.127

19/0.0824/0.08+250D

2P1P2C

2P1P2C

4C1P2C

2P1P2C

2C2C

Foam PEHD-PEHD-PE

Foam PEHD-PEHD-PE

Foam PPHD-PEHD-PE

Foam PEHD-PEHD-PE

LD-PELD-PE

0.750.600.90

0.900.600.90

0.950.700.90

0.600.480.65

0.830.95

Material Diameter(mm)

PVC

PVC

PVC

PVC

FRPE

4.50

5.00

5.00

3.90

3.50

354381150

223381150

22323994.2

560601239

239188

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : USB 3.1 : UL 758, USB 3.1 Specification USB 3.0 : UL 758, UL 1581 USB 3.0 Specification USB 2.0 : UL 444, UL 13, UL 1581, USB 2.0 Specification Member of USB-IF, Vendor code : 3054

- Passes UL VW-1 vertical flame test UL VW-1

USB 3.0 Halogen-Free : E148000 AWM STYLE 21099 80˚C 30V VW-1 -HF- -LF- PCXX USB3.0 LTK

USB 3.0 PVC : E148000 AWM STYLE 2725 80˚C 30V VW-1 -LF- PCXX USB3.0 LTK

E148000 AWM STYLE 2725 80˚C 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

USB 3.1 : E148000 AWM STYLE 2725 80˚C 30V VW-1 -LF- PCXX LTK

Page 75: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 76: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

65 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Overall

Shielding

2826

2824

2822

2820

7/0.1277/0.20

7/0.1277/0.08

7/0.1277/0.254

7/0.1277/0.32

1P2C

1P2C

1P2C

1P2C

PPSR-PVC

PPSR-PVC

PPSR-PVC

PPSR-PVC

1.201.00

1.201.10

1.201.25

1.201.45

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

Braiding,Al-Mylar

239150

23994.2

23959.4

23936.7

PVC

PVC

PVC

PVC

5.00

5.10

5.30

5.50

Material Diameter(mm)

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 105°C

- Rated voltage : 30V

- Passes CM vertical flame test CM

- Impedance : 100+/-10Ω

LVDS AWG NO/1P+AWG NO/2C 105˚C 30V LTK

PRODUCT DESCRIPTION

Conductor

AWG No./mm/

Construction Material Diameter(mm)

Overall

Shielding

343232

323232

303030

303030

303030

7/0.067/0.087/0.08

7/0.087/0.087/0.08

7/0.107/0.107/0.10

1/0.2541/0.2541/0.254

7/0.107/0.107/0.10

4P1P5C

4P1P5C

4P1P5C

4P1P5C

4P1P5C

FEPFEPFEP

FEPFEPFEP

FEPFEPFEP

XLPEXLPEXLPE

XLPEXLPEXLPE

0.500.500.50

0.700.500.50

0.800.550.55

0.800.600.60

0.900.600.60

Material Diameter(mm)

PVC

PVC

PVC

PVC

PVC

4.50

4.90

5.50

6.20

6.40

978601601

601

381

347

354

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

TinnedCopper

Insulation Jacket Max. DC Resistance

at 20°C

(ohm/km)

- Rated temperature : 105°C

- Rated voltage : 30V

- Reference standard : UL 758, HDMI1.4

- Passes UL VW-1 vertical flame test UL VW-1

- Delay Skew : Intra <=151ps, Inter <=2.42ns

- Impedance : 100+/-10Ω

- Far End Crosstalk : 26.00dB

- Attenuation : Frequency Attn (dB/m)

STANDARD AUTOMOTIVE HDMI® CABLE E148000 AWM STYLE 21149 105˚C 30V VW-1 -LF- PCXX LTK

PRODUCT DESCRIPTION

300KHz - 825MHz825MHz - 2.475GHz2.475 - 4.125GHz

<=8<=21<=30

Page 77: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

66www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.300.500.851.25

7/0.267/0.32

19/0.2419/0.29

0.780.961.201.45

0.300.300.300.30

1.401.601.802.05

50.232.721.714.9

Conductor

mm2 No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Reference standard : JASO D611-94

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

0.300.500.500.750.851.251.253.005.00

7/0.267/0.32

20/0.1830/0.1811/0.3216/0.3250/0.1841/0.3265/0.32

0.780.980.931.141.231.481.472.362.98

0.500.500.500.500.500.500.500.600.70

1.802.002.002.202.202.502.503.574.38

50.232.736.724.420.814.314.75.593.52

Conductor

mm2 No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Reference standard : JASO D611-94

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

0.50.5

0.750.851.251.25

7/0.3220/0.1830/0.1811/0.3216/0.3250/0.18

0.960.931.141.231.481.47

0.600.600.600.600.600.60

2.202.202.402.502.702.70

32.736.724.420.814.314.7

Conductor

mm2 No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 80°C

- Reference standard : JIS C3406

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

Page 78: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

67 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.220.350.500.801.002.003.005.008.00

7/0.207/0.267/0.31

19/0.2319/0.2819/0.3619/0.4519/0.5719/0.71

0.60.780.931.151.401.802.252.853.55

--

0.580.580.580.580.660.790.94

--

2.402.502.903.203.804.706.00

87.655.434.621.813.78.625.433.412.14

Conductor

mm2

24222018161412108

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated voltage : 50V

- Reference standard : SAE J1128

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

0.50.81.02.0

7/0.3219/0.2319/0.2819/0.35

1.001.201.401.80

0.580.580.580.58

2.402.502.903.20

32.724.414.38.8

Conductor

mm2

20181614

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated voltage : 50V

- Reference standard : SAE J1128

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

0.50.55.0

1.25

7/0.3220/0.1865/0.3216/0.32

0.960.932.971.47

0.500.540.800.60

2.002.004.602.70

32.736.63.5214.3

Conductor

mm2 No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)

AEXAEXAEXAVX

Category

Diameter (mm)

Insulation - Rated temperature : AEX - 120°C, AVX - 100°C

- Reference standard : JASO D 608/1992

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

Page 79: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

68www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

7/0.3216/0.2019/0.207/0.38

0.960.921.001.14

0.420.400.400.43

1.801.781.802.00

32.232.236.722.8

Conductor

0.50.50.5-

mm2

20202018

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated voltage : 50V

- Reference standard : SAE J1128

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

7/0.327/0.38

0.961.14

0.420.43

1.802.00

32.222.8

Conductor

2018

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated voltage : 50V

- Reference standard : SAE J1128

- Resistant to heat, oil, abrasion and cold

- Stranded Copper Conductor

PRODUCT DESCRIPTION

7/0.217/0.26

19/0.1919/0.2319/0.2619/0.3212/0.2116/0.2124/0.2132/0.2130/0.2650/0.2656/0.31

0.630.780.951.151.301.600.901.001.201.351.702.202.75

0.300.300.300.300.400.400.300.300.300.400.400.400.50

1.201.301.601.902.102.401.401.601.902.102.403.003.70

84.852.037.124.718.512.752.037.124.718.512.77.604.70

Conductor

0.220.350.500.751.001.500.350.500.751.001.502.504.00

mm2

AAAAAABBBBBBB

Category

No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Reference standard : DIN 72551/1996

- Resistant to heat, oil, abrasion and aging

- Stranded Copper Conductor

- Concentric or bunching stranded copper conductors available

PRODUCT DESCRIPTION

Page 80: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 81: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 82: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

71 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3634343232323030302928

7/0.051/0.167/0.0647/0.087/0.087/0.081/0.261/0.267/0.101/0.301/0.33

0.150.160.190.240.240.240.260.260.300.300.33

0.100.220.130.220.130.140.130.150.180.150.26

0.801.480.981.901.321.131.251.501.381.581.86

5075507550505050505050

Conductor

AWG No./mm/

Diameter (mm)

Nominal

Impedance

(ohm)Thickness

(mm)Diameter

(mm)

Jacket

16/3/0.0516/4/0.0516/3/0.0516/5/0.0516/4/0.0516/4/0.0516/4/0.05

16/4/0.05, 16/5/0.0516/4/0.0516/5/0.0516/4/0.08

Construction (mm)

Braid Shield

0.130.340.170.510.210.220.270.270.270.300.50

0.400.840.531.260.660.680.800.800.830.891.03

Thickness Diameter (mm)

Insulation

- Shield meets FCC RFI/EMI emission control requirements

FCC RFI/EMI

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper, silvered plated copper or copper clad steel conductor,Solid FEP insulation, Silver plated, tinned or bare copper wire braid shield, Lead free PVC or FEP jacket

4242404040363432

7/0.0257/0.0257/0.037/0.037/0.037/0.057/0.0647/0.08

0.0750.0750.090.090.090.150.190.24

0.0250.0300.010.0250.010.010.010.01

0.280.310.350.360.360.360.440.46

7100710050005000500017001000613

Conductor

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

19±1/0.0321±2/0.03

Wire Dia : 0.03Wire Dia : 0.03Wire Dia : 0.03Wire Dia : 0.03Wire Dia : 0.03Wire Dia : 0.03

Construction (mm)

Spiral Shield

0.0450.0450.0750.0750.0750.060.0690.06

0.170.180.240.240.240.270.330.36

Thickness Diameter (mm)

Insulation

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758 & UL1581

- Passes UL VW-1 vertical flame test UL VW-1

- Impedance : 50Ω

PRODUCT DESCRIPTION

Silver or tin plated tin-copper alloy conductor, Lead free TEFLON PFA insulation,Tin plated tin-copper alloy spiral shield, lead free copper and color plated PET tape or TEFLON PFA jacket

PFA 顏 PET PFA

Page 83: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

72www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

18262021222226

1/1.027/0.1619/0.1819/0.187/0.2541/0.6437/0.16

1.020.480.900.900.760.640.48

0.780.540.550.840.840.740.54

7.002.804.004.904.906.002.79

75505050507550

Conductor

AWG

RG6/URG58A/U

RG58A/U-ARG58A/U-BRG58A/U-C

RG59/URG174/U

Category

No./mm/

Diameter (mm)

Nominal

Impedance

(ohm)Thickness

(mm)Diameter

(mm)

Jacket

16/9/0.1216/4/0.1

16/3/0.1016/7/0.1216/6/0.12

0.1016/4/0.1

Construction (mm)

Braid Shield

1.810.520.801.031.101.530.54

4.571.522.502.952.953.701.52

Thickness Diameter (mm)

Insulation

- Reference standard : MIL-C-17G

- Shield meets FCC RFI/EMI emission control requirements

FCC RFI/EMI

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper, copper clad steel or silvered plated copper covered steel conductor,Solid or foamed PE insulation, Al-mylar, tinned or bare copper wire braid shield, Lead free PVC jacket

36 7/0.05 0.15 0.81

3.304.845.395.506.057.158.259.35

1.002.002.402.503.004.005.006.00

Conductor

AWG No./mm/

Diameter (mm)

Max. Attenuation

Diameter (mm)

Frequency (GHz)

Attenuation (dB/m)

Jacket

0.60

Diameter (mm)

Braid Shield

0.40

32 7/0.08 0.24 1.13

2.072.652.993.455.295.75

1.001.402.002.455.205.80

0.860.66

28 1/0.33 0.33 1.86

0.791.151.381.581.74

0.501.001.582.002.35

1.030.34

26 7/0.16 0.48 2.79

0.641.071.401.621.78

0.401.001.582.002.35

1.881.48

Diameter (mm)

Insulation

- Rated temperature : 150°C

- Rated voltage : 150V

- Passes UL VW-1 vertical flame test UL VW-1

- Impedance : 50Ω

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper, copper clad steel or silver plated copper conductor,Solid FEP, XLPE, PE or Foam PE insulation, Silver plated tinned or bare copper braid shield, Lead free PVC or FEP jacket

Page 84: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

73 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.80 1/0.8 0.75 6.00 75

Conductor

mm2

S-4C-FB

Category

No./mm/

Nominal

Impedance

(ohm)Thickness

(mm)Diameter

(mm)

Jacket

16/5/0.14

Construction (mm)

Braid Shield

1.45 3.70

Thickness Diameter (mm)

Insulation

- Rated temperature : 75°C

- Reference standard : JISC3502

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, Foam PE insulation,Al-mylar, tinned copper wire braid shield, Lead free PVC jacket

282626242424252520

7/0.121/0.401/0.401/0.501/0.501/0.507/0.1777/0.1777/0.32

0.360.400.400.500.500.500.530.530.96

0.700.540.540.740.740.740.710.660.91

3.004.004.005.005.005.005.004.905.30

757575757575757550

Conductor

AWG

1.5C-2VS2.5C-2V

2.5C-2V-A3C-2V

3C-2V-A3C-2V-B3C-2VS

3C-2VS-A3D-2V

Category

No./mm/

Diameter (mm)

Nominal

Impedance

(ohm)Thickness

(mm)Diameter

(mm)

Jacket

16/5/0.1016/2/0.1216/5/0.1216/2/0.1216/4/0.1216/5/0.1216/2/0.1216/7/0.1224/5/0.12

Construction (mm)

Braid Shield

0.621.001.001.251.251.251.291.291.02

1.602.402.403.003.003.003.103.103.00

Thickness Diameter (mm)

Insulation

- Reference standard : JISC3501

PRODUCT DESCRIPTION

Tinned or bare, stranded or solid copper conductor, PE insulation,Al-mylar, bare copper wire braid shield, Lead free PVC jacket

COAXIAL CABLE JIS S-XC-FB LTK XXXX/XX/XX ******METER

XXXX/XX/XX - Manufacturing Date

Page 85: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 86: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

75 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.750.500.751.252.000.750.750.750.750.751.250.75

30/0.18020/0.18030/0.18050/0.18037/0.26067/0.12030/0.17730/0.17730/0.17730/0.17750/0.17730/0.177

111111223333

-------

1.061.001.071.060.99

-------

6.904.35x6.70

7.258.007.70

24.440.124.415.19.224.424.424.424.424.415.124.4

Conductor

mm2

VSFHVSFHVSFHVSFHVSFHVFFHVFF

HVCTFHVCTFKHVCTFHVCTF

HVCTF-S

Category

No./mm/

No. of Cores

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Jacket

0.800.810.800.820.820.820.820.620.620.620.610.62

2.702.552.703.103.45

2.75x5.502.75x5.50

2.352.352.352.702.35

Thickness Diameter (mm)

Insulation - Rated temperature : 60°C, 75°C

- Rated voltage : 300V

- Reference standard : JIS C3306, Electrical Appliance and Material Control Law of Japan ( )

XXXX 0.75mm2 300V -F- -LF- LTK Certificate No: JET0751-XXXXX-XXXXXXXX - Category

PRODUCT DESCRIPTION

Page 87: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

76www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

1816181818

41/0.1654/0.17741/0.1641/0.1641/0.16

1.181.501.181.181.18

0.790.800.790.450.45

2.773.102.772.082.08

23.314.323.323.323.3

Conductor

AWGNo. of Cores

SJTSJTSJTSVTSVT

Category

33423

No./mm/

Diameter(mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation

0.891.010.860.820.92

7.808.758.405.806.30

Thickness (mm)

Diameter (mm)

Jacket - Rated temperature : 60°C, 75°C, 90°C, 105°C

- Rated voltage : 300V

- Reference standard : UL62, UL1581

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

PRODUCT DESCRIPTION

E166193 TYPE XXX XC x AWG NO. 105˚C 300V VW-1 --- c TYPE XXX X x XXmm2 105˚C 300V FT1 -LF- PCXX LTKXXX - Category

2020181818161818

45/0.1226/0.1641/0.1641/0.1641/0.1626/0.25441/0.1641/0.16

0.930.941.181.181.181.491.181.18

0.890.780.760.761.211.610.790.79

2.70x5.402.50x5.002.70x5.402.70x5.403.60x7.203.80x7.503.70x7.103.70x7.10

34.634.623.323.323.315.123.323.3

Conductor

AWG

SPT-1SPT-1SPT-1SPT-1SPT-2SPT-2

NISPT-2NISPT-2

Category

105601056010510560105

RatedTemperature

(°C)No./mm

/Diameter

(mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 60°C, 75°C, 90°C, 105°C

- Rated voltage : 300V

- Reference standard : UL62, UL1581

- Passes UL VW-1 & CSA FT1 vertical flame test UL VW-1 CSA FT1

E166193 TYPE XXX XC x AWG NO. 105˚C 300V VW-1 --- c TYPE XXX X x XXmm2 105˚C 300V FT1 -LF- PCXX LTKXXX - Category

PRODUCT DESCRIPTION

Page 88: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

77 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.500.500.750.750.500.750.750.751.001.502.500.751.001.502.500.751.001.502.50

16/0.216/0.224/0.224/0.216/0.224/0.224/0.224/0.232/0.230/0.2549/0.2524/0.232/0.230/0.2549/0.2524/0.232/0.230/0.2549/0.25

2222332222233334444

0.650.650.650.650.650.750.870.860.870.871.110.870.871.011.220.800.901.001.10

5.343.32x5.34

5.763.53x5.76

5.656.306.60

4.15x6.586.947.949.706.957.348.7010.507.508.009.6011.36

39.039.026.026.039.026.026.026.019.513.37.9826.019.513.37.9826.019.513.37.98

40.140.126.726.740.126.726.726.720.013.78.2126.720.013.78.2126.720.013.78.21

Conductor

mm2

227 IEC 52(RVV) -

300/300V

227 IEC 53(RVV) -

300/500V

CategoryNo./mm

/No. of Cores

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Bare Copper Tinned Copper

Jacket

0.550.550.550.550.550.550.650.650.650.760.850.650.650.760.850.600.600.700.80

2.022.022.232.232.022.232.432.432.603.103.742.432.603.103.742.402.543.103.70

Thickness Diameter (mm)

Insulation - Rated temperature : 70°C

- Rated voltage : 300/300V, 300/500V

- Reference standard : GB5023.X-2008

300/300V : CCC AXXXXXX GB/T 5023 60227 IEC 52 (RVV) 300/300V XxNO.mm2 LTKXXXXXX - Plant Code

300/500V : CCC AXXXXXX GB/T 5023 60227 IEC 53 (RVV) 300/500V XxNO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

1.502.504.004.006.006.000.501.00

1.50

1/1.381/1.781/2.257/0.851/2.767/1.041/0.8131/1.13

1/1.38

1.381.782.252.552.763.120.8131.13

1.38

0.750.830.850.850.850.850.600.60

0.70

2.883.443.954.254.464.822.062.38

2.88

12.17.414.614.613.083.0836.018.1

12.1

Conductor

mm2

227 IEC 01(BV) - 450/750

227 IEC 05(BV) - 300/500

227 IEC 07(BV) - 300/500

Category

No./mm/

Diameter(mm)

Max. DC Resistance

at 20°C

(ohm/km)Thickness

(mm)Diameter

(mm)

Insulation - Rated temperature : 70°C

- Rated voltage : 450/750V, 300/500V

- Reference standard : GB5023.X-2008

300/500V : CCC AXXXXXX GB/T 5023 60227 IEC XX (BV) 300/500V NO.mm2 LTK450/750V : CCC AXXXXXX GB/T 5023 60227 IEC XX (BV) 450/750V NO.mm2 LTK

XXXXXX - Plant Code

PRODUCT DESCRIPTION

Page 89: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

78www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.500.751.000.500.751.001.502.50

7070709090909090

28/0.1524/0.232/0.228/0.1524/0.232/0.248/0.249/0.25

0.911.131.300.911.131.301.602.02

0.600.600.600.600.600.600.700.80

2.202.392.542.402.602.783.103.68

Conductor

mm2

RatedTemperature

(°C)No./mm

/Diameter

(mm)

227 IEC 06(RV) - 300/500

227 IEC 08(RV-90) - 300/500

Category

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

39.026.019.639.026.019.613.37.98

40.126.720.040.126.720.013.78.21

Bare Copper Tinned Copper

Insulation - Rated temperature : 70°C, 90°C

- Rated voltage : 300/500V

- Reference standard : GB5023.X-2008

70°C : CCC AXXXXXX GB/T 5023 60227 IEC 06(RV) 300/500V NO.mm2 LTK90°C : CCC AXXXXXX GB/T 5023 60227 IEC 08(RV-90) 300/500V NO.mm2 LTK

XXXXXX - Plant Code

PRODUCT DESCRIPTION

1.502.504.006.00

30/0.2549/0.2556/0.3

7/12/0.3

1.582.022.593.17

0.700.800.800.80

3.103.704.275.26

Conductor

mm2

227 IEC 02(RV) - 450/750

Category

No./mm/

Diameter(mm)

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

13.37.987.983.30

13.78.218.213.39

Bare Copper Tinned Copper

Insulation

- Rated temperature : 70°C

- Rated voltage : 450/750V

- Reference standard : GB5023.X-2008

CCC AXXXXXX GB/T 5023 60227 IEC 02(RV) 450/750V NO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

4.00 19/0.52 2.60 0.80 4.26

Conductor

mm2No. of Cores

BVR450/750

Category

2

No./mm/

Diameter(mm)

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

4.61 4.70

Bare Copper Tinned Copper

Insulation

- Rated temperature : 70°C

- Rated voltage : 450/750V

- Reference standard : JB8734.X-2012

CCC AXXXXXX JB/T 8734 BVR 450/750V NO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

Page 90: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

79 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.300.300.300.300.300.200.300.300.30

16/0.1516/0.1516/0.1516/0.1516/0.1512/0.1516/0.1516/0.1516/0.15

0.690.690.690.690.690.590.690.690.69

0.500.500.500.500.500.400.500.500.50

1.731.761.761.731.731.461.731.731.73

69.269.269.269.269.292.369.269.269.2

71.271.271.271.271.295.071.271.271.2

Conductor

mm2No. of Cores

AVVR-300/300

Category

2345

1012121416

No./mm/

Diameter(mm)

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Insulation

0.600.600.600.600.600.600.800.800.80

4.885.105.556.008.607.378.709.309.80

Thickness (mm)

Diameter (mm)

Bare Copper Tinned Copper

Jacket - Rated temperature : 70°C

- Rated voltage : 300/300V

- Reference standard : JB8734.X-2012

CCC AXXXXXX JB/T 8734 AVVR 300/300V XxNO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

0.3070AV-300/300 1/0.643 0.643 0.40 1.50

Conductor

mm2

RatedTemperature

(°C)No./mm

/Diameter

(mm)

Category

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

64.1 65.3

Bare Copper Tinned Copper

Insulation - Rated temperature : 70°C

- Rated voltage : 300/300V

- Reference standard : JB8734.X-2012

CCC AXXXXXX JB/T 8734 AV 300/300V NO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

Page 91: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

80www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

0.120.300.500.120.200.300.500.751.001.500.120.200.300.500.751.001.500.120.200.300.120.300.120.200.300.120.120.120.200.30

7/0.1516/0.1528/0.157/0.1512/0.1516/0.1528/0.1542/0.1532/0.248/0.27/0.1512/0.1516/0.1528/0.1542/0.1532/0.248/0.27/0.1512/0.1516/0.157/0.1516/0.157/0.1512/0.1516/0.157/0.157/0.157/0.1512/0.1516/0.15

0.450.690.910.450.590.690.911.131.301.600.450.590.690.911.121.301.600.450.590.690.450.690.450.590.690.450.450.450.590.69

0.400.500.500.400.400.500.500.500.600.600.400.400.500.500.500.600.600.400.400.500.400.500.400.400.500.400.400.400.400.50

1.301.731.951.301.601.761.952.162.542.901.301.431.731.952.162.542.901.301.431.731.301.731.301.431.731.271.301.301.431.73

15869.239.015892.369.239.026.019.513.315892.369.239.026.019.513.315892.369.215869.215892.369.215815815892.369.2

16371.240.116395.071.240.126.720.013.716395.071.240.126.720.013.716395.071.216371.216395.071.216316316395.071.2

Conductor

mm2No. of Cores

RVVP300/300

Category

1112222222333333344455666

1012777

No./mm/

Diameter(mm)

Max. DC Resistance at 20°C

(ohm/km)

Thickness (mm)

Diameter (mm)

Insulation

0.400.400.400.600.600.600.600.600.600.800.600.600.600.600.600.800.800.600.600.600.600.600.600.600.600.600.600.600.600.60

2.603.053.254.354.905.505.806.267.008.154.555.005.706.356.607.808.805.055.366.105.456.625.806.257.146.908.155.806.247.50

Thickness (mm)

Diameter (mm)

Bare Copper Tinned Copper

Jacket

16/3/0.1016/3/0.1016/3/0.1016/4/0.1016/7/0.1016/3/0.1516/6/0.1516/4/0.1516/5/0.1516/5/0.1516/4/0.1016/3/0.1516/3/0.1516/6/0.1516/4/0.1516/5/0.1516/8/0.2016/3/0.1516/3/0.1516/6/0.1516/3/0.1516/4/0.1516/3/0.1516/6/0.1516/4/0.1516/8/0.1516/4/0.1516/3/0.1516/4/0.1516/5/0.15

No./mm

BraidingShield

- Rated temperature : 70°C

- Rated voltage : 300/300V

- Reference standard : JB8734.X-2012

CCC AXXXXXX JB/T 8734 RVVP 300/300V XxNO.mm2 LTKXXXXXX - Plant Code

PRODUCT DESCRIPTION

Page 92: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 93: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 94: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

83 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

30282624

5.105.607.007.60

4.54.34.34.5

200100100100

500500500500

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

10GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

6.605.504.403.52

0.20

11.009.907.706.49

0.60

16.5014.3011.009.46

1.25

24.2020.3515.9513.86

2.50

27.5023.6518.4816.06

3.25

35.2029.7023.6520.90

5.0

42.9035.7529.1525.30

7.0

55.0045.6539.6034.10

43434345

10.0

Delay Skew

(ps/10m)

30282624

5.105.607.007.60

4.54.34.34.5

200100100100

500500500500

AWG

Nominal

OD

(mm)

Nominal

Delay

(ns/m)

12.5GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

18.0014.5012.1010.00

1.50

27.0022.0018.3013.50

3.00

36.0528.5024.0017.50

4.50

44.0034.5029.5021.40

6.00

51.5040.5035.5028.00

7.50

55.7544.5040.0031.00

8.50

64.0050.0045.0036.00

10.0

70.0055.5050.0040.50

43434345

11.0

75.0060.5055.50N/A

12.0

Delay Skew

(ps/10m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 13

- Passes CL2 FT4 flammability test CL2 FT4

- Impedance : 100+/-5Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-Polyolefin (S-F-S) insulation, Al-mylar/PET Tape wrapping,Tinned copper braid shield, Lead free PVC jacket

30282624

4.204.705.206.00

4.54.34.34.5

15101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

10GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

6.605.504.403.60

0.20

11.009.907.706.50

0.60

16.5014.3011.009.50

1.25

24.2020.3516.5014.00

2.50

27.5023.6518.7016.10

3.25

35.2029.7024.2021.00

5.0

42.9035.7529.7025.50

7.0

55.0045.6540.7037.50

43434345

10.0

Delay Skew

(ps/m)

30282624

4.204.705.206.00

4.54.34.34.5

15101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

15GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

14.508.806.505.60

0.635

17.8013.5010.008.60

1.25

26.5020.5018.0012.80

2.50

41.0031.0027.5019.80

5.0

57.5044.5037.5029.50

8.5

64.5050.0042.5033.50

10.0

81.5063.5050.5041.50

13.5

90.0070.0054.5045.50

43434345

15.0

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 13

- Passes CL2 FT4 flammability test CL2 FT4

- Impedance : 100+/-5Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-Polyolefin (S-F-S) insulation, Al-mylar/PET Tape wrapping,Tinned copper braid shield, Lead free PVC jacket

30282624

4.204.705.206.00

4.54.34.34.5

15101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

5GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

6.605.504.403.60

0.20

11.009.907.706.50

0.60

16.5014.3011.009.50

1.25

24.2020.3516.8014.80

2.50

27.5024.2019.2017.20

3.25

35.2031.9025.2023.00

5.0

43434345

Delay Skew

(ps/m)

Page 95: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

84www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

30282624282624282624

4.504.705.206.007.608.8010.2012.4513.7016.10

4.54.54.54.54.54.54.54.54.54.5

10101010101010181412

50505050605050726050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

2P

8P

24P

Construction

Max Attenuation

(dB/m)

(GHz)Intra Inter

1.220.860.700.590.880.720.61

0.625

1.501.200.950.801.301.070.901.431.151.00

1.25

2.201.751.401.201.981.621.37

2.50

2.702.301.801.682.542.081.76

3.75

5.004.103.703.30

10.0

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Passes CL2 FT4 flammability test CL2 FT4

- Impedance : 100+/-5Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-PE insulation,Al-mylar, tinned copper braid shield, Lead free PVC or Halogen-free jacket

30282624

6.607.508.809.80

4.54.54.34.3

20101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

5GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

6.605.804.843.87

0.20

11.0010.408.477.15

0.60

16.5015.1012.1010.41

1.25

24.2021.5018.1515.25

2.50

27.5024.8520.5717.80

3.25

38.0031.5026.6223.15

5.0

43434343

Delay Skew

(ps/m)

30282624

6.607.508.809.80

4.54.54.34.3

20101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

10GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

6.605.804.843.87

0.20

11.0010.408.477.15

0.60

16.5015.1012.1010.41

1.25

24.2021.5018.1515.25

2.50

27.5024.8520.5717.80

3.25

38.0031.5026.6223.15

5.0

47.0038.8032.6729.20

7.0

60.0050.0044.7740.00

43434343

10.0

Delay Skew

(ps/m)

30282624

6.607.508.809.80

4.54.54.34.3

20101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

15GHz

Category

Nominal

Capacitance

(pF/m)

Max Attenuation

(dB/10m)

(GHz)Intra Inter

14.508.806.505.60

0.635

17.8013.5010.008.60

1.25

26.5020.5018.0012.80

2.50

41.0031.0027.5019.80

5.0

57.5044.5037.5029.50

8.5

64.5050.0042.5033.50

10.0

81.5063.5050.5041.50

13.5

90.0070.0054.5045.50

43434343

15.0

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 13

- Passes CL2 FT4 flammability test CL2 FT4

- Impedance : 100+/-5Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-Polyolefin (S-F-S) insulation, Al-mylar/PET Tape wrapping,Tinned copper braid shield, Lead free PVC jacket

Page 96: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

85 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

262422

6.998.139.65

4.254.254.25

101010

505050

AWGNominal OD

(mm)

Nominal

Delay

(ps/m)

2P

Construction

Nominal Attenuation

(dB/10m)

(GHz)Intra Inter

0.390.310.25

0.53125

0.560.460.37

1.0625

0.620.500.41

1.25

0.700.570.47

1.5625

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Passes UL VW-1 vertical flame test UL VW-1

- Impedance : 150+/-7Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-PE insulation,Al-mylar, tinned copper braid shield, Lead free PVC or Halogen-free jacket

30282624

6.607.608.8010.20

4.54.54.54.5

10101010

50505050

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

8P

Construction

Max Attenuation

(dB/10m)

(GHz)Intra Inter

1.240.880.720.61

0.625

1.701.301.070.90

1.25

1.841.451.191.00

1.25

2.271.981.621.37

2.50

2.802.542.081.76

3.75

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Passes CL2 FT4 flammability test CL2 FT4

- Impedance : 100+/-5Ω

PRODUCT DESCRIPTION

Silver plated copper conductor, Foam-PE insulation,Al-mylar, tinned copper braid shield, Lead free PVC or Halogen-free jacket

30283028

8.709.109.509.90

4.94.94.94.9

82828282

125125125125

90909090

AWGNominal OD

(mm)

Nominal

Delay

(ns/m)

25P

34P

Construction

0.610.710.610.71

Insulation

Diameter

(mm)

Nominal Impedance

(ohm)

Inter Single End Differential

Delay Skew

(ps/m)

- Rated temperature : 80°C

- Rated voltage : 30V

- Reference standard : UL 758, UL1581 & CSA C22.2 No. 210.2

- Passes UL VW-1 vertical flame test UL VW-1

PRODUCT DESCRIPTION

Tinned or bare copper conductor, PE or Foam-PE insulation,Al-mylar, tinned copper braid shield, Lead free PVC or Halogen-free jacket

Page 97: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

86www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

3.308.5012.5015.50

2.0 2.0 3.6 3.9 5.6 7.2 8.2 8.9 11.8 12.5 14.8 15.7 18.0 21.0 25.6

26262626

AWG

Nominal

OD

(mm)

RG-735A

Category

1C3C8C12C

Construction

Nominal Attenuation

(dB/100m)

Standard Signal (MB/s) 2 CEPT-1 CEPT-2 10 20 CEPT-3 DS-3 STS-1 89.472 100 CEPT-4 STS-3 200 DS-4 400

Frequency (MHz) 1.000 1.024 4.224 5.000 10.000 17.184 22.368 25.920 44.736 50.000 69.632 77.780 100.000 137.088 200.000

3.9018.9020.90

2.0 2.0 3.6 3.9 5.6 7.2 8.2 8.9 11.8 12.5 14.8 15.7 18.0 21.0 25.6242424

RG-720A1C2C16C

- Reference standard : UL444, UL13 & Bellcore-137-CORE

- Passes CM, CMR flammability test CM, CMR

- Impedance : 75Ω

PRODUCT DESCRIPTION

Silver plated copper or bare copper conductor, Foam-PE or FEP insulation,Al-mylar, single or double braid shield, Lead free PVC or Halogen-free jacket

26262624242424

5.908.1011.205.408.2011.2013.00

120120120120120120120

AWGNominal OD

(mm)

Impedance

(ohm)

E1

Category

4P12P25P

28

2025

Construction

Nominal Attenuation

(dB/100m)

(MHz)

2.2 2.7 3.81.9

2.2 2.7 3.81.9

0.772 1.024 1.576 3.156

2626262624242424

6.609.4010.9012.506.909.4011.2012.20

100100100100100100100100

5.4 8.6 12.03.0

4.5 7.2 10.02.4

AWGNominal OD

(mm)

Impedance

(ohm)

T1

Category

4P16P25P32P6P16P25P32P

Construction

Nominal Attenuation

(dB/100m)

(MHz)

1.00 4.00 10.00 20.00

- Reference standard : UL444, UL13 & Bellcore-137-CORE

- Passes CM, CMR flammability test CM, CMR

PRODUCT DESCRIPTION

Stranded or solid, tinned or bare copper conductor, PE, PVC or Foam-PE insulation, Al-mylar wrapping,Aluminum foil, single or double braid shield, Lead free PVC or Halogen-free jacket

2.54 9.8 17.4 27.9 32.8 41.0 52.5 64.6 73.2 78.730

AWG

Nominal

OD

(mm)1 10 50 100 200 400 700 900 1000

RG-179

Category

1C

Construction

Nominal Attenuation

(dB/100m)

(MHz)

Page 98: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

87 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

22223030

7.008.152.659.60

67.067.072.072.0

2.00 4.301.00

AWGNominal OD

(mm)

Capacitance

(pF/m)

SYV-75-5

SFYV-75-2

Category

1C1C1C8C

Construction

Nominal Attenuation

(dB/100m)

(MHz)

1.00 4.00

8.80

4.60 9.402.30 19.20

17.00 70.00

282828

3.4011.3012.90

72.072.072.0

3.00 4.30 11.002.10

AWGNominal OD

(mm)

Capacitance

(pF/m)

SYV-75-2

Category

1C7C8C

Construction

Nominal Attenuation

(dB/100m)

(MHz)

1.00 2.00 4.00

6.80

10.00 30.00

18.50

78.00

30.00

210.00

- Product Category : SYV-75-2, SYV-75-5, SFYV-75-2

- Passes CM, CMR flammability test CM, CMR

- Impedance : 75Ω

PRODUCT DESCRIPTION

Stranded or solid, tinned, silver plated copper or bare copper conductor, PE or FEP insulation,tinned copper braid shield, Lead free PVC or Halogen-free jacket

28282828232323232828282828

3.5510.2016.1019.604.5012.7517.2024.002.7511.0013.3014.8520.55

68.868.868.868.856.056.056.056.052.052.052.052.052.0

4.29 8.93 19.532.13

2.50 4.94 9.641.21

AWGNominal OD

(mm)

Capacitance

(pF/m)

BT3002

RA7000

RA8000

Category

1C4C8C16C1C4C8C16C1C8C12C16C32C

Construction

Nominal Attenuation

(dB/100m)

(MHz)

1.00 4.00 17.00

18.32

9.14

69.00 78.00

-

10.26

90.00

-

10.75

100.00

-

4.15 8.42 15.702.00 15.02 - - -

12.87

150.00

- Product Category : BT3002, RA7000, RA8000

- Impedance : 75Ω

PRODUCT DESCRIPTION

Bare copper conductor, Foam-PE or PE insulation,Al-mylar, single or double braid shield, Lead free PVC or Halogen-free jacket

Page 99: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 100: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

89 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

122057

1.01.02.52.5

30/0.230/0.249/0.2549/0.25

2.502.503.303.30

13.014.511.012.0

20.020.07.527.52

Conductor

mm2No. of Cores No./mm/

Diameter (mm)

Conductor

Resistance

(ohm/km)

Outer Diameter

(mm)

1.261.262.022.02

Diameter (mm)

Insulation

- Rated temperature : -40 to 70°C

- Rated voltage : 300 / 500V

- Reference standard : LIYY, YSLY-JZ/OZ, IEC 60228 (Conductor )

PRODUCT DESCRIPTION

Stranded bare copper conductor, Low temperature, flexible PVC insulation,Oil, UV resistance, Low temperature, flexible PVC jacket

1.52.54.06.010162535507095120

30/0.25 49/0.25 81/0.25 84/0.30 133/0.32 7/47/0.25 7/73/0.25 19/37/0.25 19/54/0.25 19/75/0.25 19/102/0.25 19/78/0.32

1.582.022.603.184.265.747.178.4910.312.014.015.5

13.37.984.953.301.911.210.780.550.390.270.210.16

13.78.215.093.391.951.240.800.570.390.280.210.16

0.010.0090.0070.006

0.00560.00460.00440.00380.00370.00320.00320.0029

Conductor

mm2 No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)

Conductor Resistance

3.023.704.305.406.207.909.8011.313.917.019.021.0

Diameter (mm)

Insulation

Bare Copper

(ohm/km)

Tinned Copper

(ohm/km)

- Rated temperature : -40 to 70°C Flexing : -25 to 70°C Fixed : -40 to 70°C

- Rated voltage : 450 / 750V

- Reference standard : H07V-K, IEC 60332-1, IEC 60228 (Conductor )

- Min. bending radius : >10x OD

PRODUCT DESCRIPTION

Stranded bare copper conductor, Low temperature, flexible PVC insulation,Oil, UV resistance, Low temperature, flexible PVC jacket

Page 101: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

90www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

2C3C20C25C2C3C5C7C3C5C7C4C5C2C3C5C7C2C3C7C12C18C2P3P6P

1.01.01.01.01.51.51.51.52.52.52.51010

0.750.750.750.751.51.51.51.51.50.750.750.75

30/0.230/0.230/0.230/0.230/0.2530/0.2530/0.2530/0.2549/0.2549/0.2549/0.25133/0.32133/0.3224/0.224/0.224/0.224/0.230/0.2530/0.2530/0.2530/0.2530/0.2524/0.224/0.224/0.2

2.12.12.12.12.42.52.52.53.13.13.17.07.02.02.02.02.02.52.52.52.52.52.32.32.3

5.86.213.615.46.57.08.49.58.510.511.521.223.56.26.57.47.97.28.19.713.515.710.211.213.5

20.020.020.020.012.012.012.012.07.527.527.521.661.6626.026.026.026.012.012.012.012.012.026.026.026.0

Conductor

mm2Construction No./mm/

Diameter (mm)

Conductor

Resistance

(ohm/km)

Outer Diameter

(mm)

-------------

0.100.100.100.100.100.100.100.120.120.120.120.12

Shielding

(mm)

1.261.261.261.261.581.581.581.582.022.022.024.264.261.131.131.131.131.581.581.581.581.581.131.131.13

Diameter (mm)

Insulation

- Rated temperature : -40 to 70°C

- Rated voltage : 300 / 500V

- Reference standard : LIYY, YSLY-JZ/OZ, IEC 60228 (Conductor )

PRODUCT DESCRIPTION

Stranded bare copper conductor, Low temperature, flexible PVC insulation,Tinned copper wire shielding (for shield cables only), Oil, UV resistance, Low temperature, flexible PVC jacket

Page 102: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 103: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 104: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

- Rated temperature : 90°C

- Rated voltage : 600, 1000 or 2000V

- Reference standard : UL 4703

- Passes UL VW-1 vertical flame test UL VW-1

PRODUCT DESCRIPTION

Stranded copper conductors, size 18 AWG – 2000 kcmil, or stranded aluminum or copper-clad aluminum conductor,size 12 AWG – 2000 kcmil, XLPE insulation, XLPE jacket

18 AWG 2000 kcmil 12 AWG 2000 kcmil

1816141210

600

41/0.1626/0.25441/0.25465/0.254

105/0.254

1.181.491.872.363.00

5.205.506.006.507.20

0.760.760.760.760.76

23.414.78.785.533.48

Conductor Rated

Voltage

(V)

AWG No./mm/

Diameter (mm)

Max. DC Resistance

at 20°C

(ohm/km)

1.141.141.141.141.14

1816141210

1000

41/0.1626/0.25441/0.25465/0.254

105/0.254

1.181.491.872.363.00

5.956.306.707.207.95

0.760.760.760.760.76

23.414.78.785.533.48

1.521.521.521.521.52

4mm2

6mm2

25mm2

35mm2

1000

56/0.3084/0.30

19/26/0.2547/38/0.404

2.593.177.458.70

7.408.1012.9014.30

0.760.760.760.76

5.313.340.8320.523

1.521.521.781.78

1816141210

2000

41/0.1626/0.25441/0.25465/0.254

105/0.254

1.181.491.872.363.00

5.956.306.707.207.95

0.760.760.760.760.76

23.414.78.785.533.48

1.521.521.521.521.52

Thickness

(mm)

Diameter (mm)

Insulation

Thickness (mm)

Jacket

E363614 (UL) TYPE PV Wire XXAWG 90C Dry and Wet XXXV Sun Res LTK

93 www.ltkcable.com

1. Only part of products are listed above.

2. The above information is for reference only, and is subject to the final specification. ,

Page 105: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

www.ltkcable.com

Page 106: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

95 www.ltkcable.com

1. Last updated on 2014-04-17 2014-04-172. Please contact with our sales representatiive for latest update. 繫

UL Style - Single & multiple-conductor specialty items

UL

5291 5292 5352 5361

UL Style - Multi-conductor, thermoset insulation UL

4258425942604288

4289429043114312

4313431443194320

4338435943844398

4399440044014407

4417443544364465

4468446944704471

447844864579

UL Style - Single-conductor, thermoset insulation UL

312231353137316731733182319431953196319932363239

324732483249325032653266327132723273327532813282

328632873288328932903295329632973298329933003302

331033123314331533173320332133313336333833433344

334533463347334833513352335833633364336633683373

337533763377337833793381338233833384338533863387

339333973398339934013402340634093413341534163417

342334243432343334353436343734383439344034433446

344734483452345334543456345834593463346434693470

347334753480348134853486349134923493349534963500

350235053506351135583564356535673569357835813592

359335943596359735983599360736103611361236133619

362336263631363336353649365236563657366636743681

3687368838173885

UL Style - Multiple-conductor, thermoplastic insulation UL

20922093209420952096209721012102210321512180219223052343234423662405242824442448246124622464

24682473247424812482248324932497250025012509251425172522254725512552255425622569257025742576

25862587258925902598261126122614265126612662266826792717272527332734274027892791283328352844

285128542877290729182919293529502956295729602969297529902992299620002200072000820009200102001120021

2002220034200582006620095200972009920120201532017020195201972020120233202342023520236202512025320254202762027820279

2028020292203172035020351203522035320379203822040720410204112044620460204682047520517205192052420541205492055420567

2060420620206402064420694206982071120721207222072320733207442074520749207782085020851208542085520866208682091120912

2092120936209392094020948209542095720970209892101621025210262102721028210362104721064210692107321074210802108821089

2109921100211012111521116211172111821119211202112621130211372113921140211412114221143211452114921153211542116121165

2117921198212232125321283213012130321304213052130621307213082130921310213112131321314213152131621317213182131921320

2132221323213242132521326213272132821329213302133821398213992140021401214022140321404214052140621407214082140921410

2141121412214132141421415214162145121452214532145421455214562145721458214602146121462214682146921472214732147421475

2147621492215032150421505215062150721508215092151021511215122151521516215172151821520215702157121631216322163321634

21688216892169021691216922169321776

UL Style - Single-conductor, thermoplastic insulation UL

100610071015101910281032105610611067107110951097110211071109111011121113112011501176118511951208123012321275128312841316

131713301331133213331354136513751429143014311452145314721478148614891490149414971499150015031504150515081516151715231533

153415361547155115521553155415681569157115721577158115831585158615891596159715981610161716181624163116351637163816401641

164216431645164616471649165116701672167416801681168516911697170317061719172017231728173017311732173617411759176117621763

176617691770177417771778178217831787178917921800180118041805180918181825182718281829183018331835183918481849186218631864

18651866187018711874188618951900190119051921192319261942194919661973197819841987198819891990199219991000210005100121001410023

100271003810040100411004310050100531005710059100631006410067100721007610086100901009710098100991010010101101091011310125101261013110137101381015010168

101831019210198102041021010211102121022110226102311023410235102361023710239102481026710272102731027510277102781027910283102861029010298103021030610308

103091031010311103121031310314103161032510328103311033310337103681036910388104121042610444104461044810450104531045410456104611046410468104821048310492

104931049510496104981049910501105041051510525105331054510551105531055410587106021060310668106691079410795107961079710798107991080010801108021080310804

108051083810839108401084110842108431084410845108461084710848108491085010851108521085310854108551085610857108581091810936109371093810939109401094110942

109431094410945109461094710948109491095010951109521095310958109811098210983109841098510986109871099210993110041100511006110071102511026110271102811029

11030110351104111042110431104411045110461104711048110591106011080110811108211083110841108511130112111121211213112141121511216112171125411255

Page 107: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

Size of Conductor

AWG Nominal

Cmils mm2

Diameter of Solid Conductor Cross-Sectional Area of Stranded Conductor

50494847464544434241403938373635343332313029282726252423222120191817161514131211109876543211/02/03/04/0

0.991.111.241.401.571.762.02.22.52.83.13.54.04.55.05.66.37.18.08.910.011.312.614.215.917.920.122.625.328.532.035.940.345.350.857.164.172.080.890.7101.9114.4128.5144.3162.0181.9204.3229.4257.6289.3324.9364.8409.6460.0

0.02510.02820.03150.03560.03990.04470.0510.0560.0640.0710.0790.0890.1020.1140.1270.1420.1600.1800.2030.2260.2540.2870.3200.3610.4040.4550.5110.5740.6430.7240.8130.9121.021.151.291.451.631.832.052.302.5882.9063.2643.6654.1154.6205.1895.8276.5437.3488.2529.22610.4011.68

0.981.101.231.391.551.741.982.182.482.773.073.473.964.464.955.546.247.037.928.819.9011.212.514.115.717.719.922.425.028.231.735.640.044.950.356.563.5718090101113127143160180202227255286322361406455

0.0250.0280.0310.0350.0390.0440.0500.0550.0630.0700.0780.0880.1010.1130.1260.1410.1580.1790.2010.2240.2510.2840.3180.3580.3990.4500.5060.5690.6350.7160.8050.9041.0161.1401.2781.4351.6131.802.032.292.572.873.233.634.064.575.135.776.487.268.189.1710.3111.56

0.981.231.541.962.463.104.004.846.257.849.6112.216.020.225.031.439.750.464.079.2100128159202253320404511640812102012901620205025803260411051806530823010380130901651020820262403309041740526206636083690105600133100167800211600

0.0004970.0006240.0007680.0009930.001250.001570.002030.002450.003170.003970.004870.006210.008110.01030.01270.01590.02000.02550.03240.04010.05070.06470.08040.1020.1280.1620.2050.2590.3240.4120.5190.6530.8231.041.311.652.082.633.314.175.2616.6318.36710.5513.3016.7721.1526.6733.6242.4153.4967.4385.01107.2

0.961.211.511.922.413.043.924.746.137.689.4211.915.719.824.530.838.949.462.777.698125156198248314396501627796100012641588200925283195402850766399806510172128281618020404257153242840905515686503382016103488130438164444207368

0.0004860.0006130.0007650.0009730.001220.001540.001980.002400.003120.003890.004770.006030.007960.01000.01240.01560.01970.02500.03180.03930.04970.06330.0790.1000.1260.1590.2010.2540.3180.4040.5090.6410.8071.021.281.622.042.583.244.095.166.508.2010.3413.0316.4320.7326.1432.9541.5652.4266.0883.31105.1

Minimal

Cmils mm2

Nominal

Mils mm

Minimal

Mils mm

UL Style UL Style

FRPE mPPE-PE

Rated Temperature

(°C)

Rated Voltage

(V)

PVC Halogen-Free

100710151032106111851430153315691571161716181672169124642468254727252791283529602027620379

801059080801058010580105801058080808080806060

60/8080

3006001000300300300300300306003003003030030030303030303030

33853386327510368108003385108003385-

109381080010937-

211432131121307210992109921304213042110021118

10982110281102910981109831102710983110271098311047109841104511006-

2145821457214512145121452214742145621455

1051051051058010580105801058010580808080808060608080

3006001000300300300300300306003003003030030030303030303030

Rated Temperature

(°C)

Rated Voltage

(V)

96www.ltkcable.com

1. The above information is for reference only, and is subject to the final specification.

Page 108: Wires & Cables Product Catalogue ù : ùimg105.job1001.com/upload/adminnew/2014-11-29/1417224307-9X… · JB8734.2-2012 (BVR) JB8734.3-2012 (RVS) RVS, RVV, RVVP, RVVP1 2002010105006623

[email protected]

Sales Headquarters Manufacturing Plants

Sales Contact